FIRE SPRINKLER PRODUCT INFO - 14-00352 - BYUI Science & Technology Bldg
001/020 SWAY BRACE FITTING MODELE SIZE - SYSTEM PIPE: SIZE - BRACE PIPE FMApproved - 1950 Per these instructions Load rating - see chart. ASSEMBLY - See drawing. see disclaimer below Nominal 1" or Sch. 40 Sway brace assemblies are intended to be installed in accordance with NFPA13 and the manufacturer's installation instructions. including NFPA13 13R Align brace pipe perpendicular to system pipe. Combine with proper components- . Insert brace pipe through rod bend and under channel bracket to achieve minimum 1" extension. Tighten hex nuts until gage spring lays flat or torque to 165 lb-in. * Visual inspection, verifies proper installation. AFCON : Steel thru 4" Sch. 10 and Sch. 40 1" 1 1/4" MATERIAL- S.S. (Type 304). FINISH - LISTING/APPROVAL- OSHPD FUNCTION - INSTALLATION - FEATURES ORDERING - Carbon Steel or Plain or E.G. See Website Lateral fitting of an sway brace assembly. and . Part #, size - system pipe, size - brace pipe and finish. . AFCON 4/13 Part #077 Specific products are exclusively designed to be compatible with other products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. the following warranty restriction will apply. - will warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by . shall be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non- products have been, or are used. AFCON AFCON AFCON AFCON AFCON AFCON ONLY Be advised DISCLAIMER NOT NOT P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org FM Load Ratings Size 1 1 1/4 1 1/2 2 2 1/2 3 4 FM 1" min. FM 250 250 250 1000 800 800 800 1000 1000 1000 1300 1300 1300 1500 Sch. 10 Sch. 40 CADCADCAD 077 ATTACHMENT FITTING LOCKING SIZE - BRACE PIPE MATERIAL- FINISH - 203A-EX2625 FMApproved ORDERING - : 1" and 1 1/4" Sch. 40 Plain or E.G. Part #, size - brace pipe and finish. Carbon Steel, Ductile Iron or See Website - Structure attachment fitting of an sway brace assembly. Sway brace assemblies are intended to be installed in accordance with NFPA13 and the manufacturer's installation instructions. including NFPA13 or FM 2-8. Combine with proper components- . Insert brace pipe thru fitting near pivot bolt. Tighten set bolt until head contacts bracket. * Swivel allows attachment at any angle. * Visual inspection, verifies proper installation. * Larger fastener hole available.- Consult factory. S.S. (Type 304). LISTING/APPROVAL- - 1950 OSHPD FUNCTION INSTALLATION - Per these instructions Load rating - see chart. ASSEMBLY see disclaimer below FEATURES . AFCON AFCON Specific products are exclusively designed to be compatible with other products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. the following warranty restriction will apply. - will warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by . shall be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non- products have been, or are used. AFCON AFCON AFCON AFCON AFCON AFCON ONLY Be advised DISCLAIMER NOT NOT P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 9/14 FM 17/32" 17/32" Max. Horizontal Load Size 1-1 1/4 2015 077S STEEL BASE PLATE077D DUCTILE BASE PLATE Max.Horizontal Load 630 FM 870 1620 1810 30-44° 45-59° 60-74° 75-90° Size 1-1 1/4 CADCADCADCAD 411 SWAY BRACE FITTING SIZE - SYSTEM PIPE: PATENT - No. 7,140,579 LISTING/APPROVAL 203A-EX 2625 FMApproved - 1950 Per these instructions Load rating - see chart. see disclaimer below Patented Patented Improved assembly Nominal Pipe Size Sway brace assemblies are intended to be installed in accordance with NFPA13 and the manufacturer's installation instructions. including NFPA13 or FM 2-8 Combine with proper components- . Align brace member parallel to face of 411 fastener flanges. Tighten 1/2" bolts until fastener flanges connect. * - design eliminates bending of fastener flanges during installation. * - design prevents over tightening on system pipe. * - fastener flanges connect for superior strength. * Visual inspection - proper installation when 411 fastener flanges connect. AFCON Sch. 40 Steel 1" - 12" Sch. 10 Steel 1 1/4" - 12" Sch. 7 Steel 2"-6" MATERIAL- S.S. (Type 304) FINISH - FUNCTION - INSTALLATION - FEATURES ORDERING - Carbon Steel or Plain or E.G. Longitudinal fitting of anAFCON sway brace assembly. Part #, size - system pipe and finish. ASSEMBLY - See drawing. Specific products are exclusively designed to be compatible with other products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. the following warranty restriction will apply. - will warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by . shall be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non- products have been, or are used. AFCON AFCON AFCON AFCON AFCON AFCON ONLY Be advised DISCLAIMER NOT NOT 5/14 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org Part # 077 Part # 078 FM APPROVED FM System NPS 1" - 1 1/2" 2"-3" 4" 5" 6" 8" 10-40 7-40 7-40 7-40 7-40 10-40 Sch. 420 860 860 950 2220 1340 30°-44°45°-59° 60°-74° 75°-90° 510 1030 1030 1150 2220 1620 570 1150 1150 1280 3040 1810 Certified Max. ASD Horizontal Load 27651" - 10" 12"3740 Listed Max. Horizontal Load CADCADCAD ES-A-C200_C200N Features • Extremely Compact Design • 70% Lighter than Traditional Designs • 304 (Schedule 40) Stainless Steel Housing & Sleeve • Groove Fittings Allow Integral Pipeline Adjustment • Patented Tri-Link Check Provides Lowest Pressure Loss • Unmatched Ease of Serviceability • Available with Grooved Butterfly Valve Shutoffs • Available for Horizontal, Vertical or N Pattern Installations • Replaceable Check Disc Rubber The Colt C200, C200N Double Check Valve Assemblies are used to prevent backflow of pollutants, that are objectionable but not toxic, from entering the potable water supply system. The Colt C200, C200N may be installed under continuous pressure service and may be subjected to backpressure. The Colt C200, C200N consists of two independently operating check valves, two shutoff valves, and four test cocks. For use in non-health hazard applications. The Colt C200, C200N features Lead Free* construction to comply with Lead Free* installation requirements. Specifications The Colt C200, C200N Double Check Valve Assembly shall consist of two independent Tri-Link Check modules within a single housing, sleeve access port, four test cocks and two drip tight shutoff valves. Tri-Link Checks shall be removable and serviceable, without the use of special tools. The housing shall be constructed of 304 (Schedule 40) stainless steel pipe with groove end connections. Tri-Link checks shall have reversible elastomer discs and in operation shall produce drip tight closure against the reverse flow of liquid caused by backpressure or backsiphonage. Lead Free* Double Check Valve Assembly shall be constructed using Lead Free* materials. It shall comply with state codes and standards, where applicable, requiring reduced lead content. Assembly shall be a Colt C200, C200N as manufactured by the Ames Company. ColtTM Series C200, C200N Double Check Valve Assemblies Sizes: 21⁄2" – 10" (65 – 250mm) C200N BFG C200 OSY LEAD FREE* * The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight. Job Name ________________________________________________Contractor ______________________________________________ Job Location ______________________________________________Approval _______________________________________________ Engineer _________________________________________________Contractor’s P.O. No. ______________________________________ Approval _________________________________________________Representative ___________________________________________ Ames Fire & Waterworks product specifications in U.S. customary units and metric are ap prox i mate and are pro vid ed for ref er ence only. For precise mea sure ments, please contact Ames Fire & Waterworks Tech ni cal Ser vice. Ames Fire & Waterworks re serves the right to change or modify prod uct de sign, con struc tion, spec i fi ca tions, or ma te ri als with out prior notice and without in cur ring any ob li ga tion to make such chang es and mod i fi ca tions on Ames Fire & Waterworks prod ucts previously or sub se quent ly sold. NOTICE The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are re- quired to thoroughly read all installation instructions and product safety information before beginning the installation of this product. Size (DN) DimeNSiONS weiGht A C (OSY) C (NRS) D G H I J P C200NRS C200OSY C200N NRS C200N OSY in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. lbs. kgs. lbs. kgs. lbs. kgs. 21⁄2 65 303⁄4 781 163⁄8 416 93⁄8 238 31⁄2 89 291⁄16 738 211⁄2 546 151⁄2 393 813⁄16 223 93⁄16 234 115 52 125 57 123 56 133 60 3 80 313⁄4 806 187⁄8 479 101⁄4 260 311⁄16 94 301⁄4 768 221⁄4 565 171⁄8 435 93⁄16 233 101⁄2 267 131 59 145 66 144 65 158 72 4 100 333⁄4 857 223⁄4 578 123⁄16 310 4 102 33 838 231⁄2 597 181⁄2 470 915⁄16 252 113⁄16 284 161 73 161 73 184 83 184 83 6 150 431⁄2 1105 301⁄8 765 16 406 51⁄2 140 443⁄4 1137 331⁄4 845 233⁄16 589 131⁄16 332 15 381 273 124 295 134 314 142 336 152 8 200 493⁄4 1264 373⁄4 959 1915⁄16 506 611⁄16 170 541⁄8 1375 401⁄8 1019 277⁄16 697 1511⁄16 399 173⁄16 437 438 199 480 218 513 233 555 252 10 250 573⁄4 1467 453⁄4 1162 2313⁄16 605 83⁄16 208 66 1676 491⁄2 1257 321⁄2 826 175⁄16 440 20 508 721 327 781 354 891 404 951 431 Dimensions — Weights Configurations • Horizontal • Vertical up • “N” pattern horizontal Materials • Housing & Sleeve: 304 (Schedule 40) Stainless Steel • Elastomers: EPDM, Silicone and Buna ‘N’ • Tri-Link Checks: Noryl®, Stainless Steel • Check Discs: Reversible Silicone or EPDM • Test Cocks: Bronze Body Nickel Plated • Pins & Fasteners: 300 Series Stainless Steel • Springs: Stainless Steel Size (DN) DimeNSiONS weiGht A C D G H I J P C200BFG C200NBFG in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. lbs. kgs. 21⁄2 65 273⁄4 705 8 203 31⁄2 89 297⁄8 759 211⁄2 546 1415⁄16 379 813⁄16 223 9 229 56 25 64 29 3 80 281⁄4 718 85⁄16 211 311⁄16 94 3011⁄16 779 221⁄4 565 157⁄16 392 93⁄16 233 91⁄2 241 54 24 67 30 4 100 29 737 815⁄16 227 311⁄16 94 3115⁄16 811 231⁄2 597 161⁄4 412 915⁄16 252 10 254 61 28 84 38 6 150 361⁄2 927 10 254 5 127 433⁄16 1097 331⁄4 845 1911⁄16 500 131⁄16 332 101⁄2 267 117 53 157 71 8 200 423⁄4 1086 121⁄4 311 61⁄2 165 511⁄16 1297 401⁄8 1019 235⁄16 592 1511⁄16 399 143⁄16 361 261 118 337 153 Noryl® is a registered trademark of SABIC Innovative Plastics™. hA i J G P D C A D C (open) G h J i PC200, C200N C200BFG, C200NBFG Available Models Suffix: NRS - non-rising stem resilient seated gate valves OSY - UL/FM outside stem and yoke, resilient seated gate valves BFG - UL/FM grooved gear operated butterfly valves with tamper switch *OSY FxG - Flanged inlet gate connection and grooved outlet gate connection *OSY GxF - Grooved inlet gate connection and flanged outlet gate connection *OSY GxG - Grooved inlet gate connection and grooved outlet gate connection Available with grooved NRS gate valves - consult factory* Post indicator plate and operating nut available - consult factory* *Consult factory for dimensions Pressure — Temperature Tem per a ture Range: 33°F – 140°F (0.5°C – 60°C) Maximum Working Pres sure: 175psi (12.1 bar) Approvals For additional approval information please contact the factory or visit our website at www.amesfirewater.com Capacity UL/FM Certified Flow Characteristics Flow characteristics collected using butterfly shutoff valves. Horizontal Vertical N - Pattern (**BFG & OSY Only)B64.51015 psi 14 12 10 8 6 4 2 0 0 50 100 150 200 250 300 350 gpm 0 190 380 570 760 950 1140 1330 lpm 7.5 15 fps psi 12 10 8 6 4 2 0 psi 12 10 8 6 4 2 0 0 100 200 300 400 500 gpm 0 380 760 1140 1520 1900 lpm 7.5 15 fps 21⁄2" (65mm) 3" (80mm) 0 300 600 900 1200 1500 gpm 0 1140 2280 3420 4560 5700 lpm 7.5 12 fps 6" (150mm) 0 100 200 300 400 500 600 700 800 gpm 0 380 760 1140 1520 1900 2280 2660 3040 lpm 7.5 13 fps 4" (100mm) psi 12 10 8 6 4 2 0 0 500 1000 1500 2000 2500 3000 3500 gpm 0 1900 3800 5700 7600 9500 11400 13300 lpm 7.5 10 fps 10" (250mm) psi 12 10 8 6 4 2 0 0 500 1000 1500 2000 2500 gpm 0 1900 3800 5700 7600 9500 lpm 7.5 10 fps 8" (200mm) psi 24 20 16 12 8 4 0 N VH H N V N V H N V H N H V N H V **** NOTICE Inquire with governing authorities for local installation requirements Flow capacity chart identifies valve performance based upon rated water velocity up to 25fps • Service Flow is typically determined by a rated velocity of 7.5fps based upon schedule 40 pipe. • Rated Flow identifies maximum continuous duty performance determined by AWWA. • UL Flow Rate is 150% of Rated Flow and is not recommended for continuous duty. • AWWA Manual M22 [Appendix C] recommends that the maximum water velocity in services be not more than 10fps. *UL Rated Flow *UL Rated Flow Rated Flow Rated Flow Rated Flow Service Flow Service Flow PS i D R O P (* F R i C ti ON L O S S ) PS i D R O P (* F R i C ti ON L O S S ) *UL Rated FlowRated FlowService Flow PS i D R O P (* F R i C ti ON L O S S ) *UL Rated FlowService Flow PS i D R O P (* F R i C ti ON L O S S ) *UL Rated FlowRated FlowService Flow PS i D R O P (* F R i C ti ON L O S S ) *UL Rated FlowRated FlowService Flow PS i D R O P (* F R i C ti ON L O S S ) ES-A-C200C200N 1417 © 2014 Ames Fire & Waterworks USA: Backflow Tel: (978) 689-6066 • Fax: (978) 975-8350 • AmesFireWater.com USA: Control Valves Tel: (713) 943-0688 • Fax: (713) 944-9445 • AmesFireWater.com Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • AmesFireWater.ca Latin America: Tel: (52) 81-1001-8600 • Fax: (52) 81-8000-7091 • AmesFireWater.com A Watts Water Technologies Company AHEAD OF THE FLOW ® www.nibco.com NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com 30 AHEAD OF THE FLOW ® www.nibco.com NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com Revision 9/7/2012 MATERIAL LIST PART SPECIFICATION 1. Upper Stem Stainless Steel ASTM A582 Type 416 2. Upper Bushing PTFE Bronze Sintered on Steel 3. "O" Ring EPDM 4. Body Ductile Iron ASTM A395 with Polyamide Coating 5. Disc Ductile Iron ASTM A395 with EPDM Encapsulation 6. Lower Bushing PTFE Bronze Sintered on Steel 7. Lower Stem Stainless Steel ASTM A582 Type 416 8. Dust Plug PVC 9. Nameplate Aluminum 10. Gear Operator Cast Iron and Steel 11. Indicator Flag Cast Iron 12. Handwheel Cast Iron *-8N version has two factory mounted internal supervisory switches. -4N version is gear operated only Uses NIBCO model #TS-4 Switch Kit. Polyamide coating has NSF certification. UL/ULC LISTED • FM APPROVED • 2¹⁄₂" - 10" UL LISTED FOR INDOOR AND OUTDOOR SERVICE • CALIFORNIA STATE FIRE MARSHALL LISTING NO. 7770-1243:101 • APPROVED BY THE NEW YORK CITY MEA 9-97-E, VOL.2 WHEN ASSEMBLED WITH APPROPRIATE NYC INDICATOR FLAG Fire Protection Valve • Grooved Mechanical Style • Nylon Coated Ductile Iron Body • Extended Neck • Elastomer Encapsulated Disc • Internal Supervisory Switches Standard on -8 Version • Compatible with IPS Pipe DIMENSIONS—WEIGHTS—QUANTITIES Dimensions Size A B C D E F G H In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. 2¹⁄₂ 65 2.88 73 2.72 69 0.31 8 0.63 16 3.85 98 2.42 61 11.94 303 2.91 74 3 O.D. 76.1 3.00 76 2.84 72 0.31 8 0.63 16 3.85 98 2.42 61 11.94 303 2.91 74 3 80 3.50 89 3.34 85 0.31 8 0.63 16 3.85 98 2.86 73 12.48 317 2.91 74 4 100 4.50 114 4.33 110 0.38 10 0.63 16 4.56 116 3.84 98 14.18 360 2.91 74 5 125 5.56 141 5.39 137 0.38 10 0.63 16 5.86 149 4.79 122 15.17 385 2.91 74 6 150 6.63 168 6.45 164 0.38 10 0.63 16 5.86 149 5.73 146 17.54 446 2.91 74 6 ¹⁄₂ O.D. 165.1 6.51 165 6.32 161 0.38 10 0.63 16 5.86 149 5.73 146 17.54 446 2.91 74 8 200 8.63 219 8.44 214 0.44 11 0.75 19 5.26 134 7.71 196 19.42 493 2.91 74 10 250 10.75 273 10.56 268 0.50 13 0.75 19 6.29 160 9.56 243 24.03 610 3.90 99 Dimensions Size J K L M N P Q R Weight In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. Lbs. Kg. 2¹⁄₂ 65 3.54 90 2.13 54 5.82 148 5.67 144 4.19 106 3.25 83 5.9 150 3.46 88 22 10.0 3 O.D. 76.1 3.54 90 2.13 54 5.82 148 5.67 144 4.19 106 3.25 83 5.9 150 3.46 88 22 10.4 3 80 3.54 90 2.13 54 5.82 148 5.94 151 4.44 113 3.54 90 5.9 150 3.97 101 23 10.4 4 100 3.54 90 2.13 54 7.64 194 6.31 173 5.33 135 4.35 110 5.9 150 5.03 128 28 12.7 5 125 3.54 90 2.13 54 7.64 194 7.32 186 5.83 148 4.84 123 5.9 150 6.27 159 31 14.1 6 150 3.54 90 2.13 54 7.64 194 8.62 219 7.11 181 5.93 151 5.9 150 7.25 184 41 18.6 6 ¹⁄₂ O.D. 165.1 3.54 90 2.13 54 7.64 194 8.62 219 7.11 181 5.93 151 5.9 150 7.25 184 41 18.6 8 200 3.54 90 2.13 54 7.91 201 9.80 249 8.05 204 6.87 174 9.8 250 9.25 235 53 24.1 10 250 3.98 101 3.03 77 9.49 241 11.61 295 9.86 250 9.17 233 18.0 457 11.80 300 88 40.0 GD-4765-8N* Grooved 2¹⁄₂" thru 8" GD-1765-8N 10" (not shown) 300 lb. WWP UL/FM Butterfly Valves 250 PSI WWP Iron Body Check Valves reliable Automatic Sprinkler "G" Series Fire Protection Valve • drilled & tapped for Ball drip Outlet • ePdM Seal • Bronze Seat • Stainless Steel disc & Spring Actuated MATeRIAL LIST PART SPeCIFICATION *1 . Valve Body Cast Iron, ASTM A48 Class 30A 2 . Seat Bronze C83600 or C93200, ASTM B505 3 . Clapper Stainless Steel 304, ASTM A240 **4 . Facing Seal EPDM Rubber 5 . Clamping Ring Stainless Steel 304, ASTM A240 **6 . Gasket EPDM Rubber 7 . Spring Stainless Steel 302, ASTM A313 8 . Hinge Pin Stainless Steel 303, ASTM A582 9 . Bolt Stainless Steel 304, ASTM F593 **10 . Locknut Stainless Steel 303, ASTM F594 11 . Plug ¹⁄₈" NPT Steel 12 . Plug ¹⁄₂" NPT Steel * Not field replaceable . ** Replacement seal kit . NOTe: All sizes are manufactured, listed and approved by Automatic Sprinkler and distributed by NIBCO . All sizes drilled and tapped 1/2" for a ball drip . 250 PSI/17 .2 Bar Non-Shock Cold Water GrOOVeS COnFOrM tO AnSi AWWA C-606 FOr SteeL PiPe• UL/ULC LiSted • FM APPrOVed • APPROVED BY THE NEW YORK CITY MEA 258-93-E G-917-W G-917-W (Reliable "G" Series) Grooved DIMeNSIONS—WeIGHTS—QUANTITIeS Dimension Size A Weight In . mm . In . mm . Lbs . Kg . 2¹⁄₂ 65 7 .03 179 9 4 3 80 7 .62 194 11 5 4 100 8 .44 214 17 8 6 150 10 .25 260 38 17 An automatic ball drip is available for NIBCO Underwriter's check valves . The ball drip is installed at boss location "C" on the check valve of the fire department connection . It will close against pressure, but will open when pressure is off allowing water to drain from the fire department connection . ¹⁄₂" Ball Drip # RG 22000 ³⁄₄" Ball Drip # RG 22100 90° Street elbow #T046212 PP Ball Drip NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.336.4226 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com 30 AHEAD OF THE FLOW ® www.nibco.com Revision 11/14/2014 PRINTED IN USA PAGE 1 OF 4 VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD MFG. #5401146 - REV L 3/09 General Information The Model VSR is a vane type waterfl ow switch for use on wet sprinkler systems. It is UL Listed and FM Approved for use on steel pipe; schedules 10 through 40, sizes 2" thru 8" (50 mm thru 200 mm). LPC approved sizes are 2" thru 8" (50 mm thru 200 mm). See Ordering Information chart. The VSR may also be used as a sectional waterfl ow detector on large systems. The VSR contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a fl ow of 10 GPM (38 LPM) or more occurs downstream of the device. The fl ow condition must exist for a period of time necessary to overcome the selected retard period. UL, CUL and CSFM Listed, FM Approved, LPCB Approved, For CE Marked (EN12259-5) / VdS Approved model use VSR-EU Service Pressure: 450 PSI (31 BAR) - UL Flow Sensitivity Range for Signal: 4-10 GPM (15-38 LPM) - UL Maximum Surge: 18 FPS (5.5 m/s) Contact Ratings: Two sets of SPDT (Form C) 10.0 Amps at 125/250VAC 2.0 Amps at 30VDC Resistive 10 mAmps min. at 24VDC Conduit Entrances: Two knockouts provided for 1/2" conduit. Individual switch compartments suitable for dissimilar voltages. Environmental Specifi cations: • NEMA 4/IP54 Rated Enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fi tting. • Temperature Range: 40°F - 120°F, (4.5°C - 49°C) - UL • Non-corrosive sleeve factory installed in saddle. Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 • Installation must be performed by qualifi ed personnel and in accordance with all national and local codes and ordinances. • Shock hazard. Disconnect power source before servicing. Serious injury or death could result. • Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. Ordering Information Nominal Pipe Size Model Part Number 2" DN50 VSR-2 1144402 2 1/2" DN65 VSR-2 1/2 1144425 3" DN80 VSR-3 1144403 3 1/2" - VSR-3 1/2 1144435 4" DN100 VSR-4 1144404 5" - VSR-5 1144405 6" DN150 VSR-6 1144406 8" DN200 VSR-8 1144408 Specifi cations subject to change without notice. Optional: Cover Tamper Switch Kit, stock no. 0090148 Replaceable Components: Retard/Switch Assembly, stock no. 1029030 Enclosure The VSR switches and retard device are enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A fi eld installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin number 5401103 for installation instructions of this switch. Waterfl ow switches that are monitoring wet pipe sprinkler systems shall not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Waterfl ow switches used for this application may result in unintended discharges caused by surges, trapped air, or short retard times. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866-956-1211/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MFG. #5401146 - REV L 3/09 PAGE 2 OF 4 VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Do not trim the paddle. Failure to follow these instructions may prevent the device from operating and will void the warranty. Installation (see Fig. 1) These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they shall be installed on the top side of the pipe where they will be accessible. The device should not be installed within 6" (15 cm) of a fi tting which changes the direction of the waterfl ow or within 24" (60 cm) of a valve or drain. NOTE: Do not leave cover off for an extended period of time. Drain the system and drill a hole in the pipe using a hole saw in a slow speed drill (see Fig. 1). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterfl ow. Take care not to damage the non-corrosive bushing in the saddle. The bushing should fi t inside the hole in the pipe. Install the saddle strap and tighten nuts alternately to required torque (see the chart in Fig. 1). The vane must not rub the inside of the pipe or bind in any way. ADAPTER USE (2) 5180162 ADAPTERS AS SHOWN ABOVE DN50 ONLY ADAPTER 50mm 20mm ±2mm MAX. DWG# 1146-1F Fig. 1 Compatible Pipe/ Installation Requirements Model Nominal Pipe Size Nominal Pipe O.D. Pipe Wall Thickness Hole Size U-Bolt Nuts TorqueSchedule 10 (UL) Schedule 40 (UL) BS-1387 (LPC) DN (VDS) inch mm inch mm inch mm inch mm inch mm inch mm inch mm ft-lb n-m VSR-2 2 DN50 2.375 60.3 0.109 2.77 0.154 3.91 0.142 3.6 0.091 2.3 1.25 + .125/-.062 33.0 ± 2.0 20 27 VSR-2 1/2 2.5 - 2.875 73.0 0.120 3.05 0.203 5.16 - - - - VSR-2 1/2 - DN65 3.000 76.1 - - - - 0.142 3.6 0.102 2.6 VSR-3 3 DN80 3.500 88.9 0.120 3.05 0.216 5.49 0.157 4.0 0.114 2.9 2.00 ± .125 50.8 ± 2.0 VSR-3 1/2 3.5 - 4.000 101.6 0.120 3.05 0.226 5.74 - - - - VSR-4 4 DN100 4.500 114.3 0.120 3.05 0.237 6.02 0.177 4.5 0.126 3.2 VSR-5 5 - 5.563 141.3 0.134 3.40 0.258 6.55 - - - - VSR-6 6 DN150 6.625 168.3 0.134 3.40 0.280 7.11 0.197 5.0 0.157 4.0 VSR-8 8 DN200 8.625 219.1 0.148 3.76 0.322 8.18 0.248 6.3 0.177 4.5 NOTE: For copper or plastic pipe use Model VSR-CF. Retard Adjustment The delay can be adjusted by rotating the retard adjustment knob from 0 to the max setting (60-90 seconds). The time delay should be set at the minimum required to prevent false alarms (Flowing water activates device in one direction only.) DO NOT LEAVE COVER OFF FOR AN EXTENDED PERIOD OF TIME TIGHTEN NUTS ALTERNATELY MOUNT ON PIPE SO ARROW ON SADDLE POINTS IN DIRECTION OF WATERFLOW ROLL PADDLE IN OPPOSITE DIRECTION OF WATERFLOWDIRECTION OF WATERFLOW Hole must be drilled perpendicular to the pipe and vertically centered. Refer to the Compatible Pipe/Installation Requirements chart for size. Correct Incorrect PRINTED IN USA PAGE 3 OF 4 VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD MFG. #5401146 - REV L 3/09 To remove knockouts: Place screwdriver at inside edge of knockouts, not in the center. Notes: 1. The Model VSR has two switches, one can be used to operate a central station, proprietary or remote signaling unit, while the other contact is used to operate a local audible or visual annunciator. 2. A condition of LPC Approval of this product is that the electrical entry must be sealed to exclude moisture. 3. For supervised circuits, see “Switch Terminal Connections” drawing and warning note (Fig. 4). DWG 1146-4 Fig. 5 Typical Electrical Connections Fig. 2 Do not drill into the base as this creates metal shavings which can create electrical hazards and damage the device. Drilling voids the warranty. Fig. 4 Switch Terminal Connections Clamping Plate Terminal Fig. 3 Break out thin section of cover when wiring both switches from one conduit entrance. Testing The frequency of inspection and testing for the Model VSR and its associated protective monitoring system shall be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector’s test valve shall always be used for test purposes. If there are no provisions for testing the operation of the fl ow detection device on the system, application of the VSR is not recommended or advisable. A minimum fl ow of 10 GPM (38 LPM) is required to activate this device. Advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. Fig. 7 Mounting Dimensions DWG. 1146-12DWG. 1146-12 POWER SOURCE SUITABLE FOR BELL WATERFLOW ZONE ON FIRE PANELEOLR BELL 3.50 in (89.0 mm) 2.34 in (59.4 mm) PIPE DIA. + 5.25 in (+ 133.4 mm) 5.56 in (141.2 mm)2.00 in (50.8 mm) U-BOLT NUT U-BOLT WASHER PIPE SADDLE PIPE PLASTIC PADDLE U-BOLT NOMINAL PIPE DIA. +1.75 in (+44.5 MM) FOR DN 50 – DN 65 2–2.5 in NOMINAL PIPE DIA. +2.125 in (+54.0 MM) FOR DN 80 – DN 200 3–8 in GREEN GROUND SCREWS Fig. 8 An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire become dislodged from under the terminal. Failure to sever the wire may render the device inoperable risking severe property damage and loss of life. Do not strip wire beyond 3/8" of length or expose an uninsulated conductor beyond the edge of the terminal block. When using stranded wire, capture all strands under the clamping plate. PRINTED IN USA MFG. #5401146 - REV L 3/09 PAGE 4 OF 4 VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Removal of Waterfl ow Switch • To prevent accidental water damage, all control valves should be shut tight and the system completely drained before waterfl ow detectors are removed or replaced. • Turn off electrical power to the detector, then disconnect wiring. • Loosen nuts and remove U-bolts. • Gently lift the saddle far enough to get your fi ngers under it. With your fi ngers, roll the vane so it will fi t through the hole while continuing to lift the waterfl ow detector saddle. • Lift detector clear of pipe. Fig. 6 Retard/Switch Assembly Replacement (See Fig. 6) The Retard/Switch Assembly is fi eld-replaceable without draining the system or removing the waterfl ow switch from the pipe Make sure the fi re alarm zone or circuit connected to the waterfl ow switch is bypassed or otherwise taken out of service. 1. Disconnect the power source for local bell (if applicable).2. Identify and remove all wires from the waterfl ow switch.3. Remove the (2) mounting screws holding retard/switch assembly to the base. 4. Do not remove the (2) retard housing screws. Remove the retard assembly by lifting it straight up over the tripstem. 5. Install the new retard assembly. Make sure the locating pins on the retard/switch assembly fi t into the locating pin bosses on the base. 6. Re-install the (2) original mounting screws.7. Reconnect all wires. Perform a fl ow test and place the system back in service. 8. Maintenance Inspect detectors monthly. If leaks are found, replace the detector. The VSR waterfl ow switch should provide years of trouble-free service. The retard and switch assembly are easily fi eld replaceable. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock #1029030 (see Fig. 6). There is no maintenance required, only periodic testing and inspection. DWG# 1146-10 BREAK OUT THIN SECTION OF COVER WHEN WIRING BOTH SWITCHES FROM ONE CONDUIT ENTRANCE. DO NOT REMOVE (2) RETARD HOUSING SCREWS REMOVE (2) ORIGINAL MOUNTING SCREWS HOLDING RETARD/SWITCH ASSEMBLY TO BASE RETARD/SWITCH ASSEMBLY (2) ORIGINAL MOUNTING SCREWS (2) LOCATING PINS (2) LOCATING PIN BOSSES IN BASE BASE Schedule 10 and Schedule 40 FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer of quality pipe products. Our Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube made the decision to have them approved and listed for your peace of mind. Our Sch. 10 and Sch. 40 have been through the same rigorous testing as our other fine pipe products. Bull Moose Tube’s Sch. 10 and Sch. 40 pipes are made to ASTM A135 and ASTM A795. These products are typically supplied with our protective coating but can be supplied without the coating so they can be hot-dip galvanized to meet FM requirements for use in dry systems in accordance with the zinc coating specifications of ASTM A795 or ASTM A53. All Schedule 10 and Schedule 40 pipe has a pressure rating of 300 PSI. Schedule 10 Pipe Nominal Pipe Size (in) Nominal O.D. (in) Nominal I.D. (in) Weight/Ft Bundle Size 1 1.315 1.097 1.41 lbs/ft 91 1 1/4 1.660 1.442 1.81 lbs/ft 61 1 1/2 1.900 1.682 2.09 lbs/ft 61 2 2.375 2.157 2.64 lbs/ft 37 2 1/2 2.875 2.635 3.53 lbs/ft 30 3 3.500 3.260 4.34 lbs/ft 19 4 4.500 4.260 5.62 lbs/ft 19 Schedule 40 Pipe Nominal Pipe Size (in) Nominal O.D. (in) Nominal I.D. (in) Weight/Ft Bundle Size 1 1.315 1.049 1.68 lbs/ft 70 1 1/4 1.660 1.380 2.27 lbs/ft 51 1 1/2 1.900 1.610 2.72 lbs/ft 44 2 2.375 2.067 3.66 lbs/ft 30 2 1/2 2.875 2.468 5.80 lbs/ft 30 3 3.500 3.068 7.58 lbs/ft 19 4 4.500 4.026 10.80 lbs/ft 19 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer’s instructions for the specific fitting used. A company 1819 Clarkson Road Chesterfield, MO 63017 (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com e-mail: sales@bullmoosetube.com For additional information, contact your salesperson today at (800) 325-4467 or (636) 537-2600 in the USA, or from Canada call (800) 882-4666 All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 12/09 Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage Page 1 of 4 FEBRUARY 2014 TFP172 IMPORTANT Always refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Worldwide Contacts www.tyco-fire.com General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: • A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. • A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. NOTICE The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY313 .......Upright 5.6K, 1/2˝ NPT TY323 ......Pendent 5.6K, 1/2˝ NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion-Resis- tant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* * The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/psi1/2 (80,6 LPM/bar1/2) Temperature Rating 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly .........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw . . . . . . . . Bronze Deflector .................Bronze TFP172 Page 2 of 4 Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM’s Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Components: 1/2" NPT 1 5 2 3 4 2" (50,8 mm) Frame Button Sealing Assembly *6 2 - -3 -1 *-6 Deector Compression Screw -5 4 -Bulb 2-7/8" (73,0 mm) DIA. 1-3/8" (34,9 mm) 2" (50,8 mm) WRENCH FLATS 7/16" (11,1 mm) NOMINAL MAKE-IN STYLE 15 or 20 RECESSED ESCUTCHEON 7/16" (11,1 mm) NOMINAL MAKE-IN Pipe thread connections per ISO 7-1 can be provided on special request. **DEFLECTOR * Temperature rating is indicated on Deector. DEFLECTOR * * ESCUTCHEON PLATE SEATING SURFACE ** **1/2" NPT UPRIGHTCROSS SECTION PENDENT RECESSED PENDENT WRENCH RECESS (USE ONLY END "A") WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE FIGURE 2 W-TYPE 6 SPRINKLER WRENCH FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFP172 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. MOUNTING PLATE MOUNTING SURFACE CLOSURE SERIES TY-FRB 2-7/8" DIA. (73,0 mm) FACE OF SPRINKLER FITTING 2-1/4" DIA. (57,2 mm) 1/8" (3,2 mm) 3/8±5/16" (9,5±7,9 mm) 1-3/8" (34,9 mm) 5/8" (15,9 mm) 3/4" (19,1 mm) FLUSH MOUNTING SURFACE SERIES TY-FRB CLOSURE MOUNTING PLATE 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) FACE OF SPRINKLER FITTING 1/8" (3,2 mm) 5/16±1/4" (7,9±6,4 mm)1/2" (12,7 mm) 1-3/8" (34,9 mm) FLUSH 7/8" (22,2 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON GLOBAL HEADQUARTERS | 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 TFP172 Page 4 of 4 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. TEFLON is trademark of The DuPont Corporation. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 SIN 370 5.6K UPRIGHT (1/2˝ NPT)TY313 371 5.6K PENDENT (1/2˝ NPT)TY323 SPRINKLER FINISH 1 NATURAL BRASS 3 PURE WHITE (RAL9010)** POLYESTER 4 SIGNAL WHITE (RAL9003) POLYESTER 9 CHROME PLATED TEMPERATURE RATINGS 135 135°F (57°C) 155 155°F (68°C) 175 175°F (79°C) 200 200°F (93°C) 286 286°F (141°C)** Eastern Hemisphere sales only * Use suffix “I” for ISO 7-1 connection; for example, 77-370-4-175-I TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION P/N* 77 – XXX – X – XXX Series DS-1 – 5.6 K-factor, Dry-type Sprinklers Pendent, Upright, and Horizontal Sidewall Standard Response, Standard Coverage Page 1 of 10 JANUARY 2015 TFP500 IMPORTANT Always refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Worldwide Contacts www.tyco-fire.com General Description TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Stan- dard Response (5 mm bulb), Standard Coverage Dry-type Sprinklers are dec- orative glass bulb automatic sprinklers typically used where: • pendent sprinklers are required on dry pipe systems that are exposed to freezing temperatures (e.g., sprin- kler drops from unheated portions of buildings) • sprinklers and/or a portion of the connecting piping may be exposed to freezing temperatures (e.g., sprin- kler drops from wet systems into freezers, sprinkler sprigs from wet systems into unheated attics, or hor- izontal piping extensions through a wall to protect unheated areas of a building such as loading docks, over- hangs, and building exteriors) • sprinklers are used on systems that are seasonably drained to avoid freezing (e.g., vacation resort areas) NOTICE Series DS-1 Dry-type Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association (NFPA), in addition to the standards of any other authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Series DS-1 Dry-type Sprinklers must only be installed in fittings that meet the requirements of the Design Crite- ria section. Sprinkler Identification Numbers (SINs) TY3255 – Pendent TY3155 – Upright TY3355 – Horizontal Sidewall Technical Data Approvals UL and C-UL Listed FM Approved VdS Approved TY3255 w/Standard Escutcheon only NYC Approved under MEA 352-01-E LPCB Approved Reference No. 094a/11CE Certified Certificate of Conformity No. 0832- CPD-2015 (Refer to Tables A and B for details.) Maximum Working Pressure175 psi (12,1 bar) Inlet Thread Connections 1 inch NPT ISO 7-R 1 Discharge Coefficient K=5.6 gpm/psi1/2 (80,6 lpm/bar1/2) Temperature RatingsRefer to Tables A and B. Finishes Sprinkler: Refer to Table D. Escutcheon: Refer to Table D. Physical Characteristics Inlet. . . . . . . . . . . . . . . . . . . . . . . . .Copper Plug . . . . . . . . . . . . . . . . . . . . . . . .Copper Yoke . . . . . . . . . . . . . . . . . .Stainless Steel Casing ........Galvanized Carbon Steel Insert . . . . . . . . . . . . . . . . . . . . . . . Bronze Bulb Seat ..............Stainless Steel Bulb (5 mm dia.). . . . . . . . . . . . . . . . Glass Compression Screw. . . . . . . . . . . . Bronze Deflector . . . . . . . . . . . . . . . . . . . . . Bronze Frame . . . . . . . . . . . . . . . . . . . . . . . Bronze Guide Tube .............Stainless Steel Water Tube .............Stainless Steel Spring .................Stainless Steel Sealing Assembly. . . . . . .Beryllium Nickel w/TEFLON Escutcheon . . . . . . . . . . . . . Carbon Steel TFP500 Page 2 of 10 SPRINKLER TYPE ESCUTCHEON TYPE TEMPERATURE RATING BULB COLOR CODE SPRINKLER FINISH NATURAL BRASS CHROME PLATED POLYESTER* PENDENT (TY3255) STANDARD 135°F (57°C)Orange 1, 2, 3, 4, 5, 6 1, 2, 4, 5, 6 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue 360°F (182°C)Mauve 1, 2, 3, 6 1, 2, 6 RECESSED 135°F (57°C)Orange 1, 2, 3, 5 1, 2, 5155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue 1, 2 360°F (182°C)Mauve N/A DEEP 135°F (57°C)Orange 1, 2, 3, 4, 5 1, 2, 4, 5 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue 360°F (182°C)Mauve WITHOUT 135°F (57°C)Orange 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue 360°F (182°C)Mauve 1, 2, 3 1, 2 UPRIGHT (TY3155)WITHOUT 135°F (57°C)Orange 1, 2, 3, 4, 5 1, 2, 4, 5 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue 360°F (182°C)Mauve 1, 2, 3 1, 2 Notes: 1. Listed by Underwriters Laboratories, Inc. (UL), maximum order length of 48 inches 2. Listed by Underwriters Laboratories for use in Canada (C-UL), maximum order length of 48 inches 3. Approved by FM Global (FM Approvals), maximum order length of 48 inches 4. Loss Prevention Certification Board (LPCB) and CE conformity apply to these temperature ratings only 5. Approved by the City of New York under MEA 352-01-E 6. Approved by VdS * Frame and deflector only N/A – Not Applicable TABLE A SERIES DS-1 PENDENT & UPRIGHT DRY-TYPE SPRINKLERS, 5.6K, STANDARD RESPONSE LABORATORY LISTINGS AND APPROVALS TFP500 Page 3 of 10 SPRINKLER TYPE ESCUTCHEON TYPE TEMPERATURE RATING BULB COLOR CODE SPRINKLER FINISH NATURAL BRASS CHROME PLATED POLYESTER*** HSW* (TY3355) STANDARD 135°F (57°C)Orange 1**, 2**, 3***, 4, 5 1**, 2**, 4, 5 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue 360°F (182°C)Mauve DEEP 135°F (57°C)Orange 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue 360°F (182°C)Mauve WITHOUT 135°F (57°C)Orange 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue 360°F (182°C)Mauve 1**, 2**, 5 1**, 2** Notes: 1. Listed by Underwriters Laboratories, Inc. (UL), maximum order length of 48 inches 2. Listed by Underwriters Laboratories for use in Canada (C-UL), maximum order length of 48 inches 3. Approved by FM Global (FM Approvals), maximum order length of 48 inches 4. Loss Prevention Certification Board (LPCB) and CE conformity apply to these temperature ratings only 5. Approved by the City of New York under MEA 352-01-E * Horizontal sidewall with top of deflector-to-ceiling distance of 4 to 12 inches (100 to 300 mm) ** Light and ordinary hazard occupancies only *** Light hazard occupancies only **** Frame and deflector only 5 mm BULB WATER TUBE VENT HOLE GUIDE TUBE INSERT YOKE SCREW INLET SEALING PLUG WITH CASING DEFLECTOR BULB SPRING COMPRESSION SEAT ASSEMBLY FRAME INLET BAND RECESS WRENCH FLAT WRENCH WITH SPRINKLER ENGAGEMENT IN TO ENSURE WRENCHING AREA PUSH WRENCH TABLE B SERIES DS-1 HORIZONTAL SIDEWALL (HSW) DRY-TYPE SPRINKLER, 5.6K, STANDARD RESPONSE LABORATORY LISTINGS AND APPROVALS FIGURE 1 SERIES DS-1 DRY-TYPE SPRINKLER, 5.6K, STANDARD RESPONSE ASSEMBLY FIGURE 2 W-TYPE 7 WRENCH TFP500 Page 4 of 10 2-1/4" DIA. (57,2 mm) 1-3/8" ± 1/8" (34,9 ± 3,2 mm) 2-7/8" DIA. (73,0 mm) IN 1/4" (6,4 mm) 3-3/4" to 48" INCREMENTS (95,3 to 1219,2 mm) ORDER LENGTHS: SPRINKLER FACE OF FITTING CEILING FACE OF SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) ORDER LENGTHS: (69,9 to 1219,2 mm) 2-3/4" to 48" IN 1/4" (6,4 mm) INCREMENTS FITTING FACE OF SPRINKLER (76,2 mm) 3" DIA. 1-3/4" DIA. (44,5 mm) (55,6 ± 3,2 mm) 2-3/16" ± 1/8" CEILING FACE OF SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) ORDER LENGTHS: INCREMENTS 4-1/4" ± 1/8" (108,0 ± 3,2 mm) IN 1/4" (6,4 mm) (12,7 to 1168,4 mm) 1/2" to 46" FACE OF CEILING FITTING FACE OF SPRINKLER (88,9 mm) 3-1/2" DIA. 2-1/2" DIA. (63,5 mm) CRITERIA SECTION) (REFER TO DESIGN SPRINKLER FITTING SPRINKLER FACE OF FITTING (127,0 to 1219,2 mm) INCREMENTS IN 1/4" (6,4 mm) ORDER LENGTHS: 5" to 48" DEFLECTOR TO CEILING 1-3/4" (44,5 mm) MINIMUM SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) TOP OF DEFLECTOR CRITERIA SECTION) (REFER TO DESIGN SPRINKLER FITTING SPRINKLER FITTING FACE OF IN 1/4" (6,4 mm) INCREMENTS (127,0 to 1219,2 mm) 5" to 48" ORDER LENGTHS: FIGURE 3 PENDENT (TY3255) WITH STANDARD ESCUTCHEON FIGURE 5 PENDENT (TY3255) WITH DEEP ESCUTCHEON FIGURE 4 PENDENT (TY3255) WITH STANDARD RECESSED ESCUTCHEON FIGURE 6 PENDENT (TY3255) WITHOUT ESCUTCHEON FIGURE 7 UPRIGHT (TY3155) WITHOUT ESCUTCHEON TFP500 Page 5 of 10 Operation When TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Stan- dard Response, Standard Coverage Dry-type Sprinklers are in service, water is prevented from entering the assembly by the Plug with Sealing Assembly (Ref. Figure 1) in the Inlet of the sprinkler. The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, and the Bulb Seat is released. The compressed Spring is then able to expand and push the Water Tube as well as the Guide Tube outward. This action simultaneously pulls inward on the Yoke, withdrawing the Plug with Sealing Assembly from the Inlet, allow-ing the sprinkler to activate and flow water. Design Criteria TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Stan- dard Response, Standard Coverage Dry-type Sprinklers are intended for use in fire sprinkler systems designed in accordance with the standard instal- lation rules recognized by the applica- ble listing or approval agency (e.g., UL Listing is based on NFPA 13 require- ments). For more information on LPCB Approval, contact Tyco Fire Suppres- sion & Building Products at the follow- ing office: Kopersteden 1 7547 TJ Enschede The Netherlands Tel: +31-(0)53-428-4444 Fax: +31-(0)53-428-3377 Sprinkler Fittings Install 1 inch NPT Series DS-1 Dry-type Sprinklers in the 1 inch NPT outlet or run of the following fittings: • malleable or ductile iron threaded tee fittings that meet the dimen- sional requirements of ANSI B16.3 (Class 150) • cast iron threaded tee fittings that meet the dimensional requirements of ANSI B16.4 (Class 125) Do not install Series DS-1 Dry-type Sprinklers into elbow fittings. The Inlet of the sprinkler can contact the interior of the elbow. The unused outlet of the threaded tee is plugged as shown in Figure 12. FACE OF SPRINKLER FITTING SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) CENTERLINE OF WATERWAY 1-3/4" DIA. (44,5 mm) FACE OF MOUNTING SURFACE ORDER LENGTHS: 2-3/4" to 48" (69,9 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS 3" DIA. (76,2 mm) 5/16" (7,9 mm) 2-3/8" ± 1/8" (60,3 ± 3,2 mm) 3.5° 3.5°5/16" (7,9 mm) CENTERLINE OF WATERWAY FITTING SPRINKLER FACE OF 2-1/4" (57,2 mm) DEFLECTOR TO 5-1/2" to 48" (139,7 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS ORDER LENGTHS: MINIMUM MOUNTING SURFACE SPRINKLER FITTING CRITERIA SECTION) (REFER TO DESIGN FACE OF SPRINKLER FITTING SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) CENTERLINE OF WATERWAY FACE OF MOUNTING SURFACE ORDER LENGTHS: 1/2" to 45-3/4" (12,7 to 1162,1 mm) IN 1/4" (6,4 mm) INCREMENTS 5/16" (7,9 mm) 3.5° 2-1/2" DIA. (63,5 mm) 4-1/4" ± 1/8" (108,0 ± 3,2 mm) 3-1/2" DIA. (88,9 mm) FIGURE 8 HORIZONTAL SIDEWALL (TY3355) WITH STANDARD ESCUTCHEON FIGURE 9 HORIZONTAL SIDEWALL (TY3355) WITH DEEP ESCUTCHEON FIGURE 10 HORIZONTAL SIDEWALL (TY3355) WITHOUT ESCUTCHEON TFP500 Page 6 of 10 You can also install Series DS-1 Dry- type Sprinklers in the 1 inch NPT outlet of a GRINNELL Figure 730 Mechanical Tee and GRINNELL G-FIRE Figure 522; however, the use of the Figure 730 Tee and Figure 522 for this arrangement is limited to wet pipe systems. The configuration shown in Figure 13 is only applicable for wet pipe systems where the sprinkler fitting and water- filled pipe above the sprinkler fitting are not subject to freezing and where the length of the dry-type sprinkler has the minimum exposure length depicted in Figure 11. Refer to the Exposure Length section. For wet pipe system installations of 1 inch NPT Series DS-1 Dry-Type Sprin- klers connected to CPVC piping, use only the following TYCO CPVC fittings: • 1” x 1” NPT Female Adapter (P/N 80145) • 1” x 1” x 1” NPT Sprinkler Head Adapter Tee (P/N 80249) For dry pipe system installations, use only the side outlet of maximum 2-1/2 inch reducing tee when locating Series DS-1 Dry-type Sprinklers directly below the branchline; otherwise, use the configuration shown in Figure 12 to assure complete water drainage from above Series DS-1 Dry-type Sprin- klers and the branchline. Failure to do so may result in pipe freezing and water damage. NOTICE Do not install Series DS-1 Dry-type Sprinklers into any other type fitting without first consulting the Tyco Fire Protection Products (TFPP) Technical Services. Failure to use the appropriate fitting may result in one of the following: • failure of the sprinkler to operate properly due to formation of ice over the Inlet Plug or binding of the Inlet Plug • insufficient engagement of the Inlet pipe-threads with consequent leakage Drainage In accordance with the minimum requirements of the National Fire Pro- tection Association for dry pipe sprin- kler systems, branch, cross, and feed-main piping connected to Dry Sprinklers and subject to freezing tem- peratures must be pitched for proper drainage. Exposure Length When using Dry Sprinklers in wet pipe sprinkler systems to protect areas subject to freezing temperatures, use Table C to determine a sprinkler’s appropriate exposed barrel length to prevent water from freezing in the con- necting pipes due to conduction. The exposed barrel length measurement must be taken from the face of the sprinkler fitting to the surface of the structure or insulation that is exposed to the heated area. Refer to Figure 11 for an example. For protected area temperatures between those given above, the minimum recommended length from the face of the fitting to the outside of the protected area may be determined by interpolating between the indicated values. Clearance Space In accordance with Section 8.4.9.2 of the 2010 edition of NFPA 13, when con- necting an area subject to freezing and an area containing a wet pipe sprinkler system, the clearance space around the sprinkler barrel of dry-type sprin- klers must be sealed. Due to tempera- ture differences between two areas, the potential for the formation of conden- sation in the sprinkler and subsequent ice build-up is increased. If this con- densation is not controlled, ice build-up can occur that might damage the dry- type sprinkler and/or prevent proper operation in a fire situation. Use of the Model DSB-2 Dry Sprinkler Boot, described in technical data sheet TFP591 and shown in Figures 14 and 15, can provide the recommended seal. Ambient Temperature Exposed to Discharge End of Sprinkler Temperatures for Heated Area(1) 40°F (4°C)50°F (10°C)60°F (16°C) Minimum Exposed Barrel Length(2), Inches (mm) 40°F (4°C)0 0 0 30°F (-1°C)0 0 0 20°F (-7°C) 4 (100)0 0 10°F (-12°C)8 (200)1 (25)0 0°F (-18°C)12 (305)3 (75)0 -10°F (-23°C) 14 (355) 4 (100) 1 (25) -20°F (-29°C) 14 (355) 6 (150) 3 (75) -30°F (-34°C)16 (405)8 (200)4 (100) -40°F (-40°C)18 (455)8 (200)4 (100) -50°F (-46°C) 20 (510) 10 (255) 6 (150) -60°F (-51°C) 20 (510) 10 (255) 6 (150) Notes: 1. For protected area temperatures that occur between values listed above, use the next cooler temperature. 2. These lengths are inclusive of wind velocities up to 30 mph (18,6 kph). TABLE C EXPOSED SPRINKLER BARRELS IN WET PIPE SYSTEMS MINIMUM RECOMMENDED LENGTHS TFP500 Page 7 of 10 INSULATED FREEZER STRUCTURE STRAP TIES (ENDS ON OPPOSING SIDES OF BOOT) ADHESIVE DS-1 SHOWN WITH STANDARD ESCUTCHEON 1-3/4" DIA. (44,5 mm) CLEARANCE HOLE DSB-2 BOOT INSULATED FREEZER STRUCTURE STRAP TIES (ENDS ON OPPOSING SIDES OF BOOT) ADHESIVE DS-1 SHOWN WITH STANDARD ESCUTCHEON 1-3/4" DIA. (44,5 mm) CLEARANCE HOLE DSB-2 BOOT SIDE OUTLET PLUGGED TO WET SYSTEM FITTING (SEE DESIGN CRITERIA SECTION) SPRINKLERDSB-2 INTENDED FOR FREEZER STRUCTURES HEATED AREA RUN OUTLET PLUGGED TO DRY SYSTEM DSB-2 INTENDED FOR FREEZER STRUCTURES FITTING (SEE DESIGN CRITERIA SECTION) SPRINKLER AREA SUBJECT TO FREEZING (SEE DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING LENGTH EXPOSURE DSB-2 INTENDED FOR FREEZER STRUCTURES HEATED AREA FIGURE 11 EXPOSURE LENGTH FIGURE 12 SPRINKLER FITTING UNHEATED AREA FIGURE 13 SPRINKLER FITTING HEATED AREA FIGURE 14 MODEL DSB-2 DRY SPRINKLER BOOT WITH PENDENT SERIES DS-1 DRY-TYPE SPRINKLER FIGURE 15 MODEL DSB-2 DRY SPRINKLER BOOT WITH SIDEWALL SERIES DS-1 DRY-TYPE SPRINKLER TFP500 Page 8 of 10 Installation TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Stan- dard Response, Standard Coverage Dry-type Sprinklers must be installed in accordance with this section. General Instructions Series DS-1 Dry-type Sprinklers must only be installed in fittings that meet the requirements of the Design Crite- ria section. Refer to the Design Criteria section for other important require- ments regarding piping design and sealing of the clearance space around the Sprinkler Casing. Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) rating to 1/8 inch (3,2 mm) for the 360°F (182°C) rating. Obtain a leak-tight 1 inch NPT sprinkler joint by applying a minimum-to-maxi- mum torque of 20 to 30 lbs.-ft. (26,8 to 40,2 Nm). Higher levels of torque may distort the sprinkler Inlet with conse- quent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutch- eon Plate by under or over-tightening the Sprinkler. Re-adjust the position of the sprinkler fitting to suit. Notes: • Install pendent sprinklers only in the pendent position; install upright sprinklers only in the upright posi- tion. The deflector of a pendent or upright sprinkler is to be parallel to the ceiling. • Install horizontal sidewall sprinklers in the horizontal position with their centerline of waterway perpendicu- lar to the back wall and parallel to the ceiling. Ensure the word “TOP” on the Deflector faces the ceiling. Step 1. With a non-hardening pipe- thread sealant such as TEFLON applied to the inlet threads, hand-tighten the sprinkler into the sprinkler fitting. Step 2. Wrench-tighten the sprinkler using either: • a pipe wrench on the Inlet Band or the Casing (Ref. Figure 1) • the W-Type 7 Sprinkler Wrench on the Wrench Flat (Ref. Figure 2) Apply the wrench recess of the W-Type 7 Sprinkler Wrench to the wrench flat. Note: If sprinkler removal becomes necessary, remove the sprinkler using the same wrenching method noted above. Sprinkler removal is easier when a non-hardening sealant was used and torque guidelines were followed. After removal, inspect the sprinkler for damage. Step 3. After installing the ceiling or wall and applying a ceiling finish, slide on the outer piece of the escutch- eon until it comes in contact with the ceiling/wall. Do not lift the ceiling panel out of its normal position. When using the Deep Escutcheon, hold the outer piece in contact with the mounting surface (ceiling or wall). Then rotate the inner piece approximately 1/4 turn with respect to the outer piece, to hold the Deep Escutcheon firmly together. Care and Maintenance TYCO Series DS-1 5.6K Pendent, Upright, and Horizontal Sidewall, Standard Response, Standard Cover- age Dry-type Sprinklers must be main- tained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. A Vent Hole is provided in the Bulb Seat (Ref. Figure 1) to indicate if the Dry Sprinkler is remaining dry. Evidence of leakage from the Vent Hole indicates potential leakage past the Inlet seal and the need to remove the sprinkler to determine the cause of leakage; for example, an improper installation or an ice plug. Close the fire protec- tion system control valve and drain the system before removing the sprinkler. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installa- tion section). The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. TFP500 Page 9 of 10 Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indi- cate the full product name, including description and part number (P/N). Dry-type Sprinklers When ordering Series DS-1 5.6K Pendent, Upright, and Horizontal Side- wall, Standard Response, Standard Coverage Dry-type Sprinklers, specify the following information: • SIN: TY3255 – Pendent TY3155 – Upright TY3355 – Horizontal Sidewall • Order Length: Dry-type Sprinklers are furnished based upon Order Length as mea- sured per Figures 3 through 10, as applicable. After the measurement is taken, round it to the nearest 1/4 inch increment. • Inlet Connections: 1 Inch NPT (Standard) ISO 7-R 1 (For information on ISO Inlet Thread Connections, contact your Tyco Sales Representative.) • Temperature Rating • Sprinkler Finish • Escutcheon Type and Finish, as applicable • P/N from Table D Part numbers are for 1 inch NPT standard order sprinklers. Orders for all other sprinkler assemblies must be accompanied by a complete description. Sprinkler Wrench Specify W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 Sprinkler Boot Specify Model DSB-2 Dry Sprinkler Boot, P/N 63-000-0-002 This part number includes one (1) Boot, two (2) Strap Ties, and 1/3 oz. of Adhe- sive (a sufficient quantity for installing one boot). Notes: 1. Escutcheon Finish applies to sprinklers provided with escutcheons. 2. 360°F (182°C) temperature rating applies to non-recessed sprinkler assemblies. 3. Dry-type Sprinklers are furnished based upon “Order Length” as mea- sured per Figures 3 through 10, as applicable, and for each individual sprinkler where it is to be installed. After the measurement is taken, round it to the nearest 1/4 inch increment. * Use Prefix “I” for ISO 7-R 1 Connection (e.g., I-60-961-1-180). P/N * 60 – XXX – X – XXX ORDER LENGTH(3) 055 5.50” 082 8.25” 180 18.00” 187 18.75” 372 37.25” 480 48.00” SIN 96 Pendent with Standard Escutcheon (1” NPT) TY3255 (Figure 3) 93 Pendent with Deep Escutcheon (1" NPT) TY3255 (Figure 5) 97 Pendent with Recessed Escutcheon (1" NPT) TY3255 (Figure 4) 92 Pendent without Escutcheon (1" NPT) TY3255 (Figure 6) 94 Sidewall with Standard Escutcheon (1" NPT) TY3355 (Figure 8) 53 Sidewall with Deep Escutcheon (1" NPT) TY3355 (Figure 9) 54 Sidewall without Escutcheon (1" NPT) TY3355 (Figure 10) 98 Upright without Escutcheon (1" NPT)TY3155 (Figure 7) SPRINKLER FINISH ESCUTCHEON FINISH(1) 0 CHROME PLATED SIGNAL WHITE (RAL9003) POLYESTER 1 NATURAL BRASS SIGNAL WHITE (RAL9003) POLYESTER 2 NATURAL BRASS BRASS PLATED 4 SIGNAL WHITE (RAL9003) POLYESTER SIGNAL WHITE (RAL9003) POLYESTER 9 CHROME PLATED CHROME PLATED TEMPERATURE RATING (2) 0 135°F (57°C) 1 155°F (68°C) 2 175°F (79°C) 3 200°F (93°C) 4 286°F (141°C) 5 360°F (182°C) TABLE D SERIES DS-1 DRY-TYPE SPRINKLERS, 5.6K, STANDARD RESPONSE PART NUMBER SELECTION GLOBAL HEADQUARTERS | 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 TFP500 Page 10 of 10 Copyright © 2015 Tyco Fire Products, LP. All rights reserved. TEFLON is trademark of the DuPont Corporation. Series TY-FRB — 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage Worldwide Contacts www.tyco-fire.com Page 1 of 6 FEBRUARY 2014 TFP176 IMPORTANT Always refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cau- tions with respect to handling and installation of sprinkler sys- tems and components. Improp- er handling and installation can permanently damage a sprin- kler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. General Description The Series TY-FRB, 5.6 K-factor, Hor- izontal and Vertical Sidewall Sprin- klers described in this data sheet are quick response -standard cover- age, decorative 3 mm glass bulb type spray sprinklers designed for use in light and ordinary hazard, commer- cial occupancies such as banks, ho- tels, shopping malls, etc. They are de- signed for installation along a wall or the side of a beam and just beneath a smooth ceiling. Sidewall sprinklers are commonly used instead of pendent or upright sprinklers due to aesthetics or building construction considerations, where piping across the ceiling is not desirable. The recessed version of the Series TY-FRB Horizontal Sidewall Sprin- kler is intended for use in areas with a finished wall. It uses a two-piece Style 10 Recessed Escutcheon with 1/2 inch (12,7 mm) of recessed adjust- ment or up to 3/4 inch (19,1 mm) of to- tal adjustment from the flush sidewall position, or a two-piece Style 20 Re- cessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush sidewall position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe nipples to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitabil- ity of these coatings for any given cor- rosive environment. The effects of am- bient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. NOTICE The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or sprinkler manufacturer with any questions. Sprinkler Identification Numbers TY3331 ...............Horizontal TY3431 ..................Vertical Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A for complete approv- al information including corrosion re- sistant status.) Maximum Working Pressure Refer to Table B. Discharge Coefficient K=5.6 GPM/psi1/2 (80,6 LPM/bar1/2) Temperature Ratings Refer to Table A. Finishes Sprinkler: Refer to Table C. Recessed Escutcheon: Signal or Pure White, Jet Black, Chrome Plated, or Brass Plated. TFP176 Page 2 of 6 Installation The Series TY-FRB, 5.6 K-factor, Hori- zontal and Vertical Sidewall Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb type sprin- kler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diam- eter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) to 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque may distort the sprin- kler and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuf- ficient adjustment in the escutcheon plate by under-or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. Series TY-FRB Horizontal and Vertical Sidewall Sprinkler Installation The Series TY-FRB Horizontal and Vertical Sidewall Sprinklers must be installed in accordance with the fol- lowing instructions. Step 1. Horizontal sidewall sprinklers are to be installed in the horizontal po- sition with their centerline of waterway perpendicular to the back wall and parallel to the ceiling. The word “TOP” on the Deflector is to face towards the ceiling. Vertical sidewall sprinklers are to be installed in the pendent or upright po- sition with the arrow on the Deflector pointing away from the wall. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 5), With reference to Figure 1 or 2, the W- Type 6 Sprinkler Wrench is to be ap- plied to the wrench flats. Physical Characteristics Frame ............................Bronze Button......................Brass/Copper Sealing Assembly ........Beryllium Nickel w/ TEFLON Bulb ..............................Glass Compression Screw . . . . . . . . . . . . . . . . Bronze HSW Deflector .....................Bronze VSW Deflector .....................Copper Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB, 5.6 K-factor, Hori- zontal and Vertical Sidewall Sprinklers are intended for fire protection sys- tems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM’s Loss Prevention Data Sheets). Only the Style 10 or 20 Recessed Es- cutcheon, as applicable, is to be used for recessed horizontal installations. ** * * ** * ESCUTCHEON PLATE SEATING SURFACE 1-13/16" (46,0 mm) CENTERLINE OF SPRINKLER WATERWAY 2-7/8" DIA. (73,0 mm) STYLE 10 or 20 RECESSED ESCUTCHEON 2-3/16" (55,6 mm) 1-1/2" (38,1 mm) DEFLECTOR HAT 9/16" (14,3 mm) 6 WRENCH FLATS 4 7/16" (11,1 mm) NOMINAL MAKE-IN 2 5 3 1/2" NPT 1 Pipe thread connections per ISO 7-1 can be provided on special request. Temperature rating is indicated on Deector. 1 2 Sealing Assembly Button Frame - - Bulb 3 - 4 - 6 -Deector Compression Screw 5 - FIGURE 1 5.6 K-FACTOR QUICK RESPONSE SERIES TY-FRB HORIZONTAL SIDEWALL (TY3331) SPRINKLERS TFP176 Page 3 of 6 Series TY-FRB Recessed Horizontal Sidewall Sprinkler Installation The Series TY-FRB Recessed Hori- zontal Sidewall Sprinklers must be installed in accordance with this section. Step A. Recessed horizontal sidewall sprinklers are to be installed in the horizontal position with their center- line of waterway perpendicular to the back wall and parallel to the ceiling. The word “TOP” on the Deflector is to face towards the ceiling. Step B. After installing the Style 10 or 20 Mounting Plate over the sprinkler threads, hand tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 6). With reference to Figure 1, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprin- kler wrench flats. Step D. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10 or 20 Clo- sure over the Series TY-FRB Sprinkler and push the Closure over the Mount- ing Plate until its flange comes in con- tact with the ceiling. Care and Maintenance The Series TY-FRB, 5.6 K-factor, Hori- zontal and Vertical Sidewall Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection sys- tem main control valve for mainte- nance work on the fire protection sys- tem that it controls, permission to shut down the affected fire protection sys- tem must be obtained from the prop- er authorities and all personnel who may be affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section). The owner must assure that the sprin- klers are not used for hanging any ob- jects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprin- klers, after the installation has been completed, to verify the integrity of the corrosion resistant coating. Thereaf- ter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive condi- tions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Pro- tection Association (e.g., NFPA 25), in addition to the standards of any oth- er authorities having jurisdiction. The installing contractor or sprinkler man- ufacturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, test- ed, and maintained by a qualified In- spection Service in accordance with local requirements and/or national codes. ** *** * * PENDENT UPRIGHT SECTION CROSSSHOWNSHOWN 1-1/2" (38,1 mm) ESCUTCHEON PLATE SEATING SURFACE 2-3/16" (55,6 mm) WRENCH FLATS 1/2" NPT 7/16" (11,1 mm) NOMINAL MAKE-IN ARROW MUST POINT AWAY FROM AND BE PERPENDICULAR TO THE BACK WALL SURFACE 7 2-3/16" (55,6 mm) 3 1 6 5 2 4 Pipe thread connections per ISO 7-1 can be provided on special request. Temperature rating is indicated on Deector. 1 2 Sealing Assembly Button Frame - -Bulb 3 - 4 - 6 -Deector Compression Screw 5 - FLOW Ejection Spring 7 - FIGURE 2 5.6 K-FACTOR QUICK RESPONSE SERIES TY-FRB VERTICAL SIDEWALL (TY3431) SPRINKLERS TFP176 Page 4 of 6 2-7/8" DIA. (73,0 mm) MOUNTING SURFACE CLOSURE 1-1/4" (31,8 mm) 3/4" (19,1 mm) SERIES TY-FRB MOUNTING PLATE 3/4" (19,1 mm) 1/8" (3,2 mm) 1/4" (6,4 mm) FACE OF SPRINKLER FITTING 5/8±1/4" (15,9±6,4 mm) 2-1/4" DIA. (57,2 mm) WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA 1" (25,4 mm) 1-1/4" (31,8 mm) CLOSURE 1/4" (6,4 mm) 1/2" (12,7 mm) 1/2±1/8" (12,7±3,2 mm) 2-7/8" DIA. (73,0 mm) MOUNTING SURFACE SERIES TY-FRB MOUNTING PLATE FACE OF SPRINKLER FITTING 2-1/4" DIA. (57,2 mm) 1/8" (3,2 mm) FIGURE 3 SERIES TY-FRB RECESSED HORIZONTAL SIDEWALL SPRINKLER WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON FIGURE 5 W-TYPE 6 SPRINKLER WRENCH FIGURE 6 W-TYPE 7 RECESSED SPRINKLER WRENCH FIGURE 4 SERIES TY-FRB RECESSED HORIZONTAL SIDEWALL SPRINKLER WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFP176 Page 5 of 6 NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies at a 4 to 12 inch (100 to 300 mm) top of deflector to ceiling distance. 2. Listed by Underwriters Laboratories Inc. for use in Canada (C-UL) as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies at a 4 to 12 inch(100 to 300 mm) top of deflector to ceiling distance. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers for use in Light Hazard Occupancies at a 4 to 12 inch (100 to 300 mm) top of deflector to ceiling distance. 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007a/04) at a 4 to 6 inch (100 to 150 mm) top of deflector to ceiling distance. The LPC does not rate the thermal sensitivity of horizontal sidewall sprinklers. 5. Listed by Underwriters Laboratories, Inc. as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies. 6. Listed by Underwriters Laboratories for use in Canada (C-UL) as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies. 7. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers for use in Light Hazard Occupancies. 8. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06 & 007a/04) as Quick Response Sprinklers. 9. Approved by the City of New York under MEA 354-01-E. 10. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) at a 4 to 6 inch (100 to 150 mm) top of deflector to ceiling distance. The LPC does not rate the thermal sensitivity of horizontal sidewall sprinklers. 11. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resis-tant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2” NPT) 3/4” Total Adjustment Recessed Escutcheon. ** Installed with Style 20 (1/2” NPT) 1/2” Total Adjustment Recessed Escutcheon. *** Frame and deflector only. SPRINKLER FINISH (See Note 11) K TYPE TEMP. BULB LIQUID NATURAL BRASS CHROME PLATED POLYESTER***LEAD COATED 5.6 1/2” NPT HORIZ. SIDEWALL (TY3331) 135°F (57°C)Orange 1, 2, 3, 4, 9, 10 1, 2, 3, 9 1, 2, 3, 9 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue RECESSED HORIZ. SIDEWALL (TY3331)* Figure 3 135°F (57°C)Orange 1, 2, 4, 9, 10 1, 2, 9 N/A155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green RECESSED HORIZ. SIDEWALL (TY3331)** Figure 4 135°F (57°C)Orange 1, 2, 3, 4, 9 N/A155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 5.6 1/2” NPT VERTICAL SIDEWALL (TY3431) Installed Pendent or Upright 135°F (57°C)Orange 5, 6, 7, 8, 9 5, 6, 7, 9 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue TABLE A LABORATORY LISTINGS AND APPROVALS GLOBAL HEADQUARTERS | 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 TFP176 Page 6 of 6 Copyright © 2013 Tyco Fire Products, LP. All rights reserved. TEFLON is trademark of The DuPont Corporation. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indi- cate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections: Specify: Series TY-FRB (specify SIN), (specify K-factor), (specify) Horizontal Sidewall or Vertical Sidewall Sprinkler, Standard Response, Standard Cov- erage, (specify) temperature rating, (specify) finish or coating, P/N (spec- ify from Table C) Recessed Escutcheon Specify: Style (10 or 20) Recessed Es- cutcheon with (specify*) finish, P/N (specify*). * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories, Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. SPRINKLER FINISH K TYPE NATURAL BRASS CHROME PLATED POLYESTER LEAD COATED 5.6 1/2” NPT HORIZONTAL SIDEWALL (TY3331) 250 PSI (17,2 BAR) or 175PSI (12,1 BAR) (SEE NOTE 1)RECESSED HORIZ. SIDEWALL (TY3331) VERTICAL SIDEWALL (TY3431)175 PSI (12,1 BAR) SPRINKLER FINISH 1 NATURAL BRASS 3 PURE WHITE (RAL9010)* POLYESTER 4 SIGNAL WHITE (RAL9003) POLYESTER 5 JET BLACK (RAL9005)** POLYESTER 7 LEAD COATED 9 CHROME PLATED * Eastern Hemisphere sales only. ** Available in 155°F (68°C) or 200°F (93°C) temperature rating only. SIN 378 HORIZONTAL SIDEWALL TY3331 375 VERTICAL SIDEWALL TY3431 TEMPERATURE RATINGS 135 135°F (57°C) 155 155°F (68°C) 175 175°F (79°C) 200 200°F (93°C) 286 286°F (141°C) P/N 57 – XXX – X – XXX TABLE B MAXIMUM WORKING PRESSURE TABLE C PART NUMBER SELECTION SERIES TY-FRB HORIZONTAL AND VERTICAL SIDEWALL SPRINKLERS Worldwide Contacts www.tyco-fire.com Series RFII — 5.6 K-factor “Royal Flush II” Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage Page 1 of 4 MARCH 2013 TFP181 IMPORTANT Always refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Worldwide Contacts www.tyco-fire.com General Description The TYCO Series RFII 5.6 K-factor, “Royal Flush II” Concealed Pendent Sprinklers Quick Response (3-mm bulb) and Standard Response (5-mm bulb), are decorative sprinklers featur- ing a flat cover plate designed to con- ceal the sprinkler. These sprinklers are optimal for architecturally sensitive ar- eas such as hotel lobbies, office build- ings, churches, and restaurants. Each sprinkler includes a Cover Plate/ Retainer Assembly and a Sprinkler/ Support Cup Assembly. The separa- ble, two-piece assembly design pro- vides the following benefits: • Allows installation of the sprinklers and pressure testing of the fire pro- tection system prior to installation of a suspended ceiling or applica- tion of the finish coating to a fixed ceiling. • Permits the removal of suspended ceiling panels for access to building service equipment without having to first shut down the fire protection system and remove sprinklers. • Provides for 1/2 inch (12,7 mm) of vertical adjustment to allow a mea- sure of flexibility in determining the length of fixed piping to cut for the sprinkler drops. The Series RFII Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap is temporarily removed during installation and replaced to help protect the sprinkler during ceiling in- stallation or finish. The tip of the Pro- tective Cap can be used to mark the center of the ceiling hole into plaster board or ceiling tiles by gently push- ing the ceiling product against the Pro- tective Cap. When ceiling installation is complete, the Protective Cap is re- moved and the Cover Plate/Retainer Assembly is installed. As an option, the Series RFII Standard Response (5-mm bulb) “Royal Flush II” Concealed Pendent Sprinklers can be fitted with a silicone Air and Dust Seal. (Refer to Figure 5.) The Air and Dust Seal is intended for sensitive areas where it is desirable to prevent air and dust from the area above the ceiling to pass through the cover plate. NOTICE The Series RFII Concealed Pendent Sprinklers described herein must be installed and maintained in compli- ance with this document and with the applicable standards of the National Fire Protection Association, in addi- tion to the standards of any authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY3531 — 3 mm bulb TY3551 — 5 mm bulb Technical Data Sprinkler Approvals Approvals apply only to the service conditions indicated in the Design Cri- teria section. • TY3531 (3-mm Bulb) is UL Listed, C-UL Listed, VdS Approved (Certif- icate No. G4090007), and NYC Ap- proved (MEA 353-01-E) as Quick Response. • TY3531 (3-mm Bulb) is FM and LPCB Approved (Ref. No. 094a/10) Approved as Standard Response. Factory Mutual and LPCB do not approve any concealed sprinklers for quick response. • TY3551 (5-mm Bulb) is UL Listed, C-UL Listed, FM Approved, LPCB Approved (Ref. No. 094a/9), and NYC Approved (MEA 353-01-E) as Standard Response. Approvals for Air and Dust Seal UL and C-UL Listed for use with the RFII Standard Response Concealed Sprinkler (TY3551). Maximum Working Pressure Maximum 250 psi (17,3 bar) by UL, C-UL, and NYC Maximum 175 psi (12,1 bar) by FM, VdS, and LPCB Temperature Rating 155°F (68°C) Sprinkler with 139°F (59°C) Plate 200°F (93°C) Sprinkler with 165°F (74°C) Plate Discharge Coefficient K= 5.6 GPM/psi1/2 (80,6 LPM/bar1/2) Adjustment 1/2 inch (12,7 mm) Finishes See the Ordering Procedure section. TFP181 Page 2 of 4 Physical Characteristics Frame . . . . . . . . . . . . . . . . . . . Bronze Support Cup. . . . . . . . . . . . . .Chrome Plated Steel Guide Pins .........Stainless Steel Deflector .................Bronze Compression Screw . . . . . . . . . Brass Bulb ......................Glass Cap .............Bronze or CopperSealing Assembly . . . . . . . . .Beryllium Nickel w/ TEFLONCover Plate . . . . . . . . . . . . . . . . Brass Retainer . . . . . . . . . . . . . . . . . . BrassEjection Spring ......Stainless Steel Design Criteria The TYCO Series RFII 5.6 K-factor, “Royal Flush II” Concealed Pendent Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency; for example, UL List- ing is based on NFPA 13 and VdS Ap- proval is based on the CEA 4001. For more information on LPCB and VdS Approvals, contact Tyco Fire Pro- tection Products at the following office: Enschede, Netherlands Telephone: 31-53-428-4444 Fax: 31-53-428-3377 The Series RFII Concealed Pendent Sprinklers are only listed and approved with the Series RFII Concealed Cover Plates having a factory applied finish. NOTICE Do not use the Series RFII in applica- tions where the air pressure above the ceiling is greater than that be- low. Down drafts through the Sprin- kler/Support Cup Assembly can delay sprinkler operation in a fire situation. Operation When exposed to heat from a fire, the Cover Plate, normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup Assembly. The Deflector — supported by the Guide Pins — then drops down to its operational position. The glass bulb contains a fluid that ex- pands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, activating the sprinkler and allowing water to flow. SPRINKLER/SUPPORT CUP ASSEMBLY COVER PLATE/RETAINER ASSEMBLY GUIDE PINS (2) DEFLECTOR (DROPPED POSITION) COMPRESSION SCREW DEFLECTOR SUPPORT CUP WITH ROLL FORMED THREADS FRAME 1/2" NPT CAP BULB SEALING ASSEMBLY RETAINER WITH THREAD DIMPLES EJECTION SPRING SOLDER TABS (3) COVER PLATE THREAD INTO SUPPORT CUP UNTIL MOUNTING SURFACE IS FLUSH WITH CEILING FIGURE 1 MODEL RFII CONCEALED SPRINKLER ASSEMBLY Installation The TYCO Series RFII 5.6 K-factor, “Royal Flush II” Concealed Pendent Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 155°F (68°C) and 3/32 inch (2,4 mm) for the 200°F (93°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler In- let with consequent leakage or impair- ment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Sprinkler by under- or over-tightening the Sprin- kler/Support Cup Assembly. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler only in the pendent position with the center-line of the sprinkler perpendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant ap- plied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 4. Wrench-tighten the sprinkler using only the RFII Sprinkler Wrench. (Refer to Figure 3.) Apply the RFII Sprinkler Wrench to the Sprinkler as shown in Figure 3. Step 5. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. (Refer to Figure 4.) The Protective Cap helps prevent damage to the Deflector and TFP181 Page 3 of 4 COVER PLATE PROFILE DEPTH DIMENSION B 1/2" (12,7 mm) THREADED ADJUSTMENTD FACE OF SPRINKLER FITTING MANUFACTURER PRESET GAP 3/32" (2,4 mm) FACE OF CEILING, RETAINING RING MOUNTING SURFACE SPRINKLER SUPPORT CUP ASSEMBLY CLEARANCE HOLE DIAMETER DIMENSION C DEFLECTOR IN DROPPED POSITION 3/16" to 11/16" (4,8 to 17,5 mm) REFERENCE COVER PLATE RETAINER ASSEMBLY COVER PLATE DIAMETER DIMENSION A A: 3-1/4 inches (82,6 mm)C: 2-3/8 to 2-5/8 inches (60,3 to 66,7 mm) B: 3/16 inches (4,8 mm)D: 1-3/4 to 2-1/4 inches (44,5 to 57,2 mm) FIGURE 2 SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS FRAME ARM SUPPORT CUP 7/8" (23 mm) SQUARE ACCEPTS 1/2" SOCKET DRIVE ALIGN ARROWS WITH FRAME ARMS FIGURE 3 RFII SPRINKLER WRENCH CLEARANCE HOLE FIGURE 4 DISPOSABLE PROTECTIVE CAP Arms during ceiling installation and/or finish. You can also use the Protective Cap to locate the center of the clear- ance hole by gently pushing the ceiling material up against the center point of the Protective Cap. NOTICE As long as the Protective Cap remains in place, the system is considered “Out of Service”. Step 6. After the ceiling has been com- pleted with the 2-1/2 inch (63,5 mm) di- ameter clearance hole and in prepa- ration for installing the Cover Plate/ Retainer Assembly, remove and dis- card the Protective Cap. Verify that the Deflector moves up and down freely. If the Sprinkler is damaged and the Deflector does not move up and down freely, replace the entire Sprinkler. Do not attempt to modify or repair a damaged sprinkler. Step 7. When installing an Air and Dust Seal, refer to Figure 5; otherwise, proceed to Step 8. To attach the Air and Dust Seal, verify the angle of the outside edge of the seal is oriented ac- cording to Figure 5. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. Step 8. Screw on the Cover Plate/ Retainer Assembly until the Retainer (shown in Figure 2) or the Air and Dust Seal (shown in Figure 5) contacts the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly so that it lifts a ceiling panel out of its normal position. If you cannot engage the Cover Plate/Retainer Assembly with the Support Cup or you cannot engage the Cover Plate/Retainer As- sembly sufficiently to contact the ceil- ing, you must reposition the Sprinkler Fitting. TFP181 Page 4 of 4 Copyright © 2013 Tyco Fire Products, LP. All rights reserved. TEFLON is trademark of The DuPont Corporation. GLOBAL HEADQUARTERS | 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 Care and Maintenance The TYCO Series RFII 5.6 K-fac- tor, “Royal Flush II” Concealed Pen- dent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection sys- tem from the proper authorities and notify all personnel who may be affect- ed by this action. Absence of the Cover Plate/Retainer Assembly can delay sprinkler opera- tion in a fire situation. When properly installed, there is a nominal 3/32 inch (2,4 mm) air gap be- tween the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper operation of the sprinkler. If the ceil- ing requires repainting after sprinkler installation, ensure that the new paint does not seal off any of the air gap. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) Exercise care to avoid damage to sprinklers before, during, and after in- stallation. Replace sprinklers damaged by dropping, striking, wrench twisting, wrench slipping, or the like. Also, re- place any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Refer to the Installation section.) SUPPORT CUP SPRINKLER AIR AND DUST SEALCOVER PLATE LIP OF RETAINER FACE OF CEILING ORIENT SEAL BEVEL AS SHOWNCOVER PLATE RETAINER ASSEMBLY FIGURE 5 OPTIONAL AIR AND DUST SEAL FOR SERIES RFII (TY3551) If you must remove a sprinkler, do not reinstall it or a replacement without re- installing the Cover Plate/Retainer As- sembly. If a Cover Plate/Retainer As- sembly becomes dislodged during service, replace it immediately. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and devic- es in compliance with this document, as well as with the applicable stan- dards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any other authori- ties having jurisdiction. Contact the in- stalling contractor or sprinkler manu- facturer regarding any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national code. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name. Sprinkler/Support Cup Assembly Specify: Series RFII (specify SIN), K=5.6, “Royal Flush II” Pendent Sprin- klers (specify) temperature rating and (specify) finish, P/N (specify). 155°F (68°C)200°F (93°C) TY3531 51-792-1-155 51-792-1-200 TY3551 51-790-1-155 51-790-1-200 Separately Ordered Cover Plate/ Retainer Assembly: Specify: (temperature rating from be- low) Series RFII Concealed Cover Plate with (finish), P/N (specify). 139°F (59°C)(a) 165°F (74°C)(b) Grey White (RAL9002) ....56-792-0-135 56-792-0-165 Brass ..........56-792-1-135 56-792-1-165 Pure White (c) (RAL9010) ....56-792-3-135 56-792-3-165 Signal White (RAL9003) ....56-792-4-135 56-792-4-165 Jet Black (RAL9005) ....56-792-6-135 59-792-6-165 Brushed Chrome ........56-792-8-135 56-792-8-165 Chrome ........56-792-9-135 56-792-9-165 Custom ........56-792-X-135 56-792-X-165 (a) For use with 155°F (68°C) sprinklers. (b) For use with 200°F (93°C) sprinklers. (c) Eastern Hemisphere sales only. Sprinkler Wrench Specify: RFII Sprinkler Wrench, P/N 56-000-1-075. Air and Dust Seal Specify: Air and Dust Seal, P/N 56-908-1-001. General Description The TYCO Model ELOC, 11.2 K-fac- tor, Extended Coverage, Light Hazard, Extra Large Orifice Concealed (ELOC) Pendent Sprinklers are decorative, fast response solder type sprinklers featuring a flat cover plate designed to conceal the sprinkler. When limited water pressure is available, the ELOC is the best choice for architectural- ly sensitive areas such as hotel lob- bies, office buildings, churches, and restaurants. They are intended for use in automatic sprinkler systems designed in accor- dance with standard installation rules (e.g., NFPA 13). The fast response thermal sensitivity rating of the Mod- el ELOC (TY5522) provides for a quick response extended coverage (QREC) rating up to an 18 ft. x 18 ft. coverage area. Each unit includes a Cover Plate As- sembly that conceals the sprinkler op- erating components above the ceiling. The separable two-piece design of the Cover Plate and Support Cup Assem- blies allows installation of the sprin- klers and pressure testing of the fire protection system prior to installation of a suspended ceiling or application of the finish coating to a fixed ceiling. They also permit removal of suspend- ed ceiling panels for access to build- ing service equipment without having to first shut down the fire protection system and remove sprinklers. Also, the separable two-piece design of the Sprinkler provides for 3/4 inch (19,1 mm) of vertical adjustment to provide a measure of flexibility with re- gard to which the length of fixed pipe drops to the sprinklers must be cut. The Model ELOC Sprinklers are shipped with a Disposable Protec- tive Cap. The Protective Cap is tem- porarily removed for installation, and it can be replaced to help protect the sprinkler while the ceiling is being in- stalled or finished. The tip of the Pro- tective Cap can also be used to mark the center of the ceiling hole into plas- ter board, ceiling tiles, etc. by gently pushing the ceiling product against the Protective Cap. When the ceiling installation is complete the Protective Cap is removed and the Cover Plate Assembly installed. As an option, the Model ELOC Pen- dent Sprinklers may be fitted with a silicone Air and Dust Seal (Ref. Fig. 4). The Air and Dust Seal is intended for sensitive areas where it is desirable to stop air and dust travel through the cover plate from the area above the ceiling. NOTICE The Model ELOC Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any authorities having ju- risdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Number TY5522 TY5522 is a redesignation for C5522. Model ELOC — 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick and Standard Response, Extended Coverage Page 1 of 4 APRIL 2015 TFP250 IMPORTANT Always refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cau- tions with respect to handling and installation of sprinkler sys- tems and components. Improp- er handling and installation can permanently damage a sprin- kler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Worldwide Contacts www.tyco-fire.com Technical Data Approvals UL and C-UL Listed NYC Approved under MEA 177-03-E (The listings apply only to the service conditions indicated in the Design Cri- teria section.) Approvals for Air & Dust Seal UL and C-UL Listed for use with the Model ELOC (TY5522); however, all listed coverage areas are rated stan- dard response (Ref. Table A). Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K= 11.2 gpm/psi1/2 (161,3 lpm/bar 1/2) Temperature Rating 160°F (71°C) Sprinkler/ 139°F (59°C) Plate 212°F (100°C) Sprinkler/ 165°F (74°C) Plate Adjustment 3/4 inch (19,1 mm) Finishes Refer to Ordering Procedure section. Physical Characteristics Body . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Brass Cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze Saddle . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Brass Sealing Assembly ..Beryllium Nickel w/TEFLON Solder Link Halves . . . . . . . . . . . . . . . . . . Nickel Lever . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze Compression Screw . . . . . . . . . . . . . . . . . .Brass Deflector . . . . . . . . . . . . . . . . . . . . Bronze/Brass Guide Pin Housing . . . . . . . . . . . . . . . . . .Bronze Guide Pins . . . . . . . . . . . . . . . . . . Stainless Steel Support Cup . . . . . . . . . . . . . . . . . . .Plated Steel Cover Plate . . . . . . . . . . . . . . . . . . . . . . . . .Brass Retainer . . . . . . . . . . . . . . . . . . . . . . . . . . . .Brass Cover Plate Ejection Spring ....Stainless Steel Operation When exposed to heat from a fire, the Cover Plate, normally soldered to the Retainer at three points, falls away to expose the Sprinkler Assembly. At this point the Deflector supported by the Guide Pins drops down to its opera- tional position. When the rated temperature of the Solder Link Element is reached, the Link Element separates, allowing the sprinkler to activate and flow water. TFP250 Page 2 of 4 RESPONSE RATING SPACING MINIMUM FLOW/PRESSURE QUICK*16’ x 16’ (4,9 m x 4,9 m)30.0 GPM/7.2 PSI (113,6 LPM/0,50 BAR) QUICK*18’ x 18’ (5,5 m x 5,5 m) 33.0 GPM/8.7 PSI (124,9 LPM/0,60BAR) STANDARD 20’ x 20’ (6,1 m x 6,1 m)40.0 GPM/12.8 PSI (151,4 LPM/0,88 BAR) * The 16’ x 16’ and 18’ x 18’ coverage areas are rated Standard Response when the Air and Dust Seal (Fig. 4) is utilized. SPRINKLER/SUPPORT CUP ASSEMBLY COVER PLATE/RETAINER ASSEMBLY COVER PLATE EJECTION SPRING RETAINER WITH THREAD DIMPLES SOLDER TAB SEALING ASSEMBLY COMPRESSION SCREW DEFLECTOR (OPERATED POSITION) SPRINKLER WRENCHING HEX SOLDER LINK ELEMENT SUPPORT CUP WITH ROLL FORMED THREADS GUIDE PIN GUIDE PIN HOUSING THREAD INTO SUPPORT CUP UNTIL MOUNTING SURFACE IS FLUSH WITH CEILING BODY (3/4" NPT) LEVER DEFLECTOR SADDLE CAP FIGURE 1 MODEL ELOC PENDENT SPRINKLER ASSEMBLY (TY5522) TABLE A MODEL ELOC 160°F (71°C) AND 212 °F (100°C) PENDENT SPRINKLER (TY5522) HYDRAULIC DESIGN CRITERIA Design Criteria The Model ELOC (TY5522) Pendent Sprinklers are UL and C-UL Listed for use in light hazard occupancies, using the design criteria in Table A, in addi- tion to the requirements specified in the current NFPA 13 for extended cov- erage pendent sprinklers. The ELOC Pendent Sprinklers are only listed and approved with the ELOC Concealed Cover Plates having a fac- tory applied finish. The ELOC must not be used in appli- cations where the air pressure above the ceiling is greater than that below. Down drafts through the Support Cup could delay sprinkler operation in a fire situation. Installation The TYCO Model ELOC must be in- stalled in accordance with this section. General Instructions A leak tight 3/4 inch NPT sprinkler joint should be obtained with a mini- mum to maximum torque of 10 to 20 ft.-lbs. (13,4 to 26,8 Nm). Higher levels of torque may distort the sprinkler in- let with consequent leakage or impair- ment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Sprinkler Assembly by under-or over-tightening the Sprinkler/Support Cup Assembly. Readjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must only be in- stalled in the pendent position and with the centerline of the sprinkler per- pendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 4. Wrench tighten the sprinkler using only the W-Type 18 Sprinkler Wrench (Ref. Figure 3). The W-Type 18 Sprinkler Wrench is to be applied to the Sprinkler as shown in Figure 3. Step 5. Replace the Protective Cap (Ref. Figure 2) by pushing it upwards until it bottoms out against the Sup- port Cup. The Protective Cap helps prevent damage to the Deflector and Arms during ceiling installation and/or during application of the finish coating of the ceiling. It may also be used to locate the center of the clearance hole TFP250 Page 3 of 4 TIP 3/4" NPT 3-3/16" DIA. (81,0 mm) 2-1/2" DIA. (63,5 mm) MOUNTING SURFACE3/16" (4,8 mm) FACE OF SPRINKLER FITTING DEFLECTOR IN OPERATED POSITION SPRINKLER- SUPPORT CUP ASSEMBLY OPERATED SPRINKLER SPRINKLER- SUPPORT CUP ASSEMBLY COVER- RETAINER ASSEMBLY COVER PLATE RETAINER DISPOSABLE PROTECTIVE CAP 3/32" GAP (2,4 mm) 3/4" (19,1 mm) THREADED ADJUSTMENT 2-1/8"±3/8" (54,0 mm ±9,5 mm) 3/8" (9,5 mm) 1-1/8" (28,6 mm) FRAME ARM SUPPORT CUP ALIGN ARROWS WITH FRAME ARMS ACCEPTS 1/2" DRIVE OR 7/8" OPEN-END WRENCH SPRINKLER WRENCHING HEX WRENCH HEX RECESS FIGURE 2 MODEL ELOC PENDENT SPRINKLER INSTALLATION DIMENSIONS FIGURE 3 W-TYPE 18 SPRINKLER WRENCH by gently pushing the ceiling material against the center point of the Protec- tive Cap. NOTICE As long as the Protective Cap remains in place, the system is considered to be “Out of Service”. Step 6. After the ceiling has been completed with the 2-1/2 inch (63,5 mm) diameter clearance hole and in preparation for installing the Cover Plate Assembly, remove and discard the Protective Cap, and verify that the Deflector moves up and down freely. If the Sprinkler has been damaged and the Deflector does not move up and down freely, replace the entire Sprin- kler assembly. Do not attempt to mod- ify or repair a damaged sprinkler. Step 7. When installing an Air and Dust Seal, refer to Figure 4, otherwise proceed to Step 8. To attach the Air and Dust Seal, verify the angle of the outside edge of the seal is oriented according to Figure 4. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. Step 8. Screw on the Cover Plate/ Retainer Assembly until the Retainer (Figure 2) or Air and Dust Seal (Fig- ure 4) contacts with the ceiling. Do not continue to screw on the Cover Plate/ Retainer Assembly such that it lifts a ceiling panel out of its normal position. If the Cover Plate/Retainer Assembly cannot be engaged with the Support Cup or the Cover Plate/Retainer As- sembly cannot be engaged sufficient- ly to contact the ceiling, the Sprinkler Fitting must be repositioned. Care and Maintenance The TYCO Model ELOC must be maintained and serviced in accor- dance with this section. Before closing a fire protection sys- tem main control valve for mainte- nance work on the fire protection sys- tem that it controls, permission to shut down the affected fire protection sys- tem must be obtained from the prop- er authorities and all personnel who may be affected by this action must be notified. Absence of the Cover Plate Assem- bly may delay sprinkler operation in a fire situation. When properly installed, there is a nominal 3/32 inch (2,4 mm) air gap between the lip of the Cov- er Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper operation of the sprinkler. If the ceiling is to be repainted after the in- stallation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be re- placed, if necessary, by factory paint- ed units. Non-factory applied paint may adversely delay or prevent sprin- kler operation in the event of a fire. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section.) The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and devic- es in compliance with this document, as well as with the applicable stan- dards of the National Fire Protection Association (e.g., NFPA 25), in addi- tion to the standards of any other au- thorities having jurisdiction. Contact the installing contractor or product manufacturer with any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indi- cate the full product name and Part Number (P/N). Sprinkler Assembly Specify: TY5522, (specify temperature rating) Model ELOC Pendent Sprin- kler, P/N (specify) 160°F (71°C) 212°F (100°C) TY5522 ....50-701-1-160 50-701-1-212 Separately Ordered Cover Plate Specify: (specify temperature rating) Model ELOC Cover Plate with (specify finish), P/N (specify) 139°F (59°C)(a) 165°F (74°C)(b) Grey White (RAL 9002) . . . . . . . . . 56-892-0-135 56-892-0-165 Brass ....56-892-1-135 56-892-1-165Pure White (RAL 9010)(c) . . . . . . . . . 56-892-3-135 56-892-3-165 Signal White (RAL 9003) . . . . . . . . . 56-892-4-135 56-892-4-165 Chrome...56-892-9-135 56-892-9-165 Custom ...56-892-X-135 56-892-X-165 (a) For use with 160°F (71°C) sprinklers (b) For use with 212°F (100°C) sprinklers (c) Eastern Hemisphere sales only Sprinkler Wrench Specify: W-Type 18 Sprinkler Wrench, P/N 56-000-1-265 Air and Dust Seal Specify: Air and Dust Seal, P/N 56-908-1-001 GLOBAL HEADQUARTERS | 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 TFP250 Page 4 of 4 Copyright © 2015 Tyco Fire Products, LP. All rights reserved. TEFLON is trademark of The DuPont Corporation SUPPORT CUP AIR AND DUST SEALCOVER PLATE LIP OF RETAINER FACE OF CEILING ORIENT SEAL BEVEL AS SHOWNCOVER PLATE RETAINER ASSEMBLY SPRINKLER FIGURE 4 OPTIONAL AIR AND DUST SEAL FOR MODEL ELOC (TY5522) Victaulic offers a broad line of fittings in sizes through 48”/1200 mm in a variety of straight and reducing styles. Most standard fittings are cast of durable ductile iron to precise tolerances. Victaulic standard fittings pressure ratings conform to the ratings of Victaulic Style 77 couplings. All fittings are supplied with grooves or shoulders to permit fast installation without field prepara- tion. The grooved design permits flexibility for easy alignment. These fittings are not intended for use with Victaulic couplings for plain end pipe (refer to Section 14.04 for fittings available for plain end applications). Fittings are provided in various materials including ductile iron, steel or segmentally welded steel depending on styles and size. Fittings are painted orange enamel with a galvanized finish avail- able as an option, contact Victaulic for details. Victaulic fittings are designed specifically for use in grooved piping systems. Fittings are provided grooved or with shoulders conforming to standard steel pipe outside diameters. When connecting wafer or lug-type butterfly valves directly to Victaulic fittings with 741 or 743 Vic-Flange® adapt- ers, check disc clearance dimensions with I.D. dimension of fitting. Advanced Groove System – For 14 – 24"/350 – 600 mm piping systems, Victaulic now offers the Advanced Groove System (AGS). Refer to Section 20.05 for AGS fitting details. Stainless Steel – Grooved end fittings are available in Schedule 10 Type 316 stainless steel (Schedule 5, 40 and Type 304 available as an option) in various sizes. Fitting center-to-end dimensions will vary depending upon type and schedule. Refer to Section 17.04 and 17.16 for details. Aluminum – Grooved end fittings are available in aluminum alloy 356 T6, in sizes from 1 – 8"/25 – 200 mm. Refer to Section 21.03 or contact Victaulic for details. AGS – ADVANCED GROOVE SYSTEM ALTERNATE STYLES Extra Heavy EndSeal ® “ES” Fittings – EndSeal fittings are available in 2 – 12"/50 – 300 mm for use with “ES” grooved pipe and HP-70ES EndSeal couplings. “ES” fittings are painted black for easy identification. EndSeal (and standard) fittings may be easily internally coated (by others) for severe service requirements. Always specify “ES EndSeal fittings” when ordering. See Section 07.03 for information on EndSeal fittings. Fittings Machined for Rubber or Urethane Lining (MRL) – For severe abrasive services, Victaulic fittings may be rubber or urethane lined (by others). Lining may be inside diameter/end (abrasion resistance) or wrap-around (corrosion and/or abrasion) machined. Refer to Section 25.03 or contact Victaulic for specific details. 07.01_1 Grooved End Fittings NO. 20 TEE 07.01IPS CARBON STEEL PIPE - GROOVED FITTINGS JOB/OWNER CONTRACTOR ENGINEER System No. __________________________ Submitted By ________________________ Spec Sect ____________ Para __________ Location ____________________________ Date ________________________________ Approved ___________________________ Date ________________________________ www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_L NO. 10 ELBOW FLOW DATA (Frictional Resistance) The chart expresses the frictional resistance of various Victaulic fittings as equivalent feet of straight pipe. Fittings not listed can be estimated from the data given, for example, a 22½ ° elbow is approximately one-half the resistance of a 45° elbow. Values of mid-sizes can be interpolated. Size Dimension – Feet/meters Nominal Size In./mm Actual Outside Dia. In./mm Elbows Tees 90° Elbows 45° Elbows Branch Run No. 10 Std. Radius No. 100 1½ D Long Radius No. 11 Std. Radius No. 110 1½ D Long Radius 11.3151.7 —0.8 —4.2 1.7 25 33.7 0.5 0.2 1.3 0.5 2 2.375 3.5 2.5 1.8 1.1 8.5 3.5 50 60.3 1.1 0.8 0.5 0.3 2.6 1.1 76.1 mm 3.000 4.3 —2.1 —10.8 4.3 76.1 1.3 0.7 3.3 1.3 3 3.500 5.0 3.8 2.6 1.6 13.0 5.0 80 88.9 1.5 1.2 0.8 0.5 4.0 1.5 108.0 mm 4.250 6.4 —3.2 —15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 5.0 3.4 2.1 16.0 6.8 100 114.3 2.1 1.5 1.0 0.6 4.9 2.1 133.0 mm 5.250 8.1 —4.1 —20.0 8.1 133.0 2.5 1.2 6.2 2.5 139.7 mm 5.500 8.5 —4.2 —21.0 8.5 139.7 2.6 1.3 6.4 2.6 55.5638.5 —4.2 —21.0 8.5 125 141.3 2.6 1.3 6.4 2.6 159.0 mm 6.250 9.4 —4.9 —25.0 9.6 159.0 2.9 1.5 7.6 2.9 165.1 mm 6.500 9.6 s—5.0 —25.0 10.0 165.1 2.9 1.5 7.6 3.0 66.62510.07.5 5.03.025.010.0 150 168.3 3.0 2.3 1.5 0.9 7.6 3.0 88.62513.09.86.54.033.013.0 200 219.1 4.0 3.0 2.0 1.2 10.1 4.0 10 10.750 17.0 12.0 8.3 5.0 41.0 17.0 250 273.0 5.2 3.7 2.5 1.5 12.5 5.2 12 12.750 20.0 14.5 10.0 6.0 50.0 20.0 300 323.9 6.1 4.4 3.0 1.8 15.2 6.1 14 14.000 #15.8 #11.0 70.0 23.0 350 355.6 4.8 3.4 21.3 7.0 16 16.000 #18.0 #13.0 80.0 27.0 400 406.4 5.5 4.0 24.4 8.2 18 18.000 #20.0 #14.0 90.0 30.0 450 457.0 6.1 4.3 27.4 9.1 20 20.000 #22.5 #16.0 100.0 33.0 800 508.0 6.9 4.9 30.5 10.1 24 24.000 #27.0 #19.0 120.0 40.0 600 610.0 8.2 5.8 36.6 12.2 26 26.000 #28.0 #20.5 130.0 43.0 650 660.4 8.5 6.3 39.6 13.1 30 30.000 #34.0 #24.0 150.0 50.0 750 762.0 10.4 7.3 45.7 15.2 36 36.000 #40.5 #28.5 180.0 60.0 900 914.0 12.3 8.7 54.9 18.3 42 42.000 #47.0 #33.0 210.0 70.0 1050 1067.0 14.3 10.1 64.0 21.3 07.01_2 Grooved End Fittings 07.01IPS CARBON STEEL PIPE - GROOVED FITTINGS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_L NO. 20 TEENO. 10 ELBOW MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. • Or: Segmentally welded steel as shown under nipples Nipples: (adapter, swaged & hose) • ¾ – 4"/20 – 100 mm: Carbon steel, Schedule 40, conforming to ASTM A-53, Type F • 5 – 6"/125 – 150 mm: Carbon steel, Schedule 40, conforming to ASTM A-53, Type E or S, Gr. B • 8 – 12"/200 – 300 mm: Carbon steel, Schedule 30 or 40, conforming to ASTM A-53, Type E or S, Gr. B Flanged Adapter Nipples: (Nipple – see above) • Class 125 Flange: Cast iron conforming to ANSI B-16.1 • Class 150 Flange: Carbon steel conforming to ANSI B-16.5, raised or flat face • Class 300 Flange: Carbon steel conforming to ANSI B-16.5, raised or flat face Fitting Coatings: Orange enamel • Optional: Hot dip galvanized and others. Some fittings supplied electroplated as standard – see product specifications. Flanged Adapter Nipple Coating: None (Unfinished) • Optional: Orange enamel, hot dip galvanized and others. 07.01_3 Grooved End Fittings 07.01IPS CARBON STEEL PIPE - GROOVED FITTINGS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_L NO. 20 TEENO. 10 ELBOW Elbows NO. 10 90º Elbow NO. 11 45º Elbow NO. 12 22½º Elbow NO. 13 11¼º Elbow NO. 100 90º Long Radius NO. 110 45º Long Radius (Ductile Iron *) DIMENSIONS C to E C to E NO. 10 C to E NO. 11 C to E E to E NO. 12 C to E NO. 13 C to E NO. 100 C to E NO. 110 Size No. 10 90º Elbow No. 11 45º Elbow No. 12 22½° Elbow (sw) No. 13 11¼° Elbow (sw) No. 100† 90° Long Radius Elbow (S) No. 110† 45° Long Radius Elbow (S) Nominal Size Inches mm Actual Outside Dia. Inches mm C to E Inches mm Approx. Wgt. Each Lbs. kg C to E Inches mm Approx. Wgt. Each Lbs. kg C to E Inches mm Approx. Wgt. Each Lbs. kg C to E Inches mm Approx. Wgt. Each Lbs. kg C to E Inches mm Approx. Wgt. Each Lbs. kg C to E Inches mm Approx. Wgt. Each Lbs. kg ¾ 1.050 2.25 0.5 1.50 0.5 1.63 sw —1.38 sw —————20 26.9 57 0.2 38 0.2 41 35 1 1.315 2.25 0.6 1.75 0.6 3.25 @ 0.6 1.38 sw 0.3 ————25 33.7 57 0.3 44 0.3 83 0.3 35 0.1 1 ¼ 1.660 2.75 1.0 1.75 0.9 1.75 0.8 1.38 sw 0.5 ————32 42.4 70 0.5 44 0.4 44 0.4 35 0.2 1 ½ 1.900 2.75 1.2 1.75 0.9 1.75 0.8 1.38 sw 0.5 ————40 48.3 70 0.5 44 0.4 44 0.4 35 0.2 2 2.375 3.25 1.8 2.00 1.3 3.75 @ 1.4 1.38 1.0 4.38 2.5 2.75 1.8 50 60.3 83 0.8 51 0.6 95 0.6 35 0.5 111 1.1 70 0.8 2 ½ 2.875 3.75 3.2 2.25 2.2 4.00 @ 2.3 1.50 1.1 5.00 4.1 3.00 2.8 65 73.0 95 1.5 57 1.0 102 1.0 38 0.5 127 1.9 76 1.3 76.1 mm 3.000 3.75 3.7 2.25 3.4 ————————76.1 95 1.7 57 1.5 3 3.500 4.25 4.5 2.50 3.1 4.50 @ 3.1 1.50 2.1 5.88 6.0 3.38 4.9 80 88.9 108 2.0 64 1.4 114 1.4 38 1.0 149 2.7 86 2.2 3 ½ 4.000 4.50 5.6 2.75 4.3 2.50 sw 4.0 1.75 sw 2.7 ————90 101.6 114 2.5 70 2.0 64 1.8 44 1.2 4 4.500 5.00 7.1 3.00 5.6 2.88 5.6 1.75 3.6 7.50 12.3 4.00 7.3 100 114.3 127 3.2 76 2.5 73 2.5 44 1.6 191 5.6 102 3.3 108.0 mm 4.250 5.00 11.0 3.00 5.6 ————————108.0 127 5.0 76 2.5 4 ½ 5.000 5.25 sw 10.0 3.13 sw 6.0 3.50 6.6 1.88 sw 4.2 ————120 127.0 133 4.5 79 2.7 89 3.0 48 1.9 5 5.563 5.50 11.7 3.25 8.3 2.88 sw 7.8 2.00 sw 5.0 +18.2 +14.8 125 141.3 140 5.3 83 3.8 73 3.5 51 2.2 8.3 6.7 133.0 mm 5.250 5.50 11.7 3.25 8.3 ————————133.0 140 5.3 83 3.8 139.7 mm 5.500 5.50 11.7 3.25 8.3 ————————139.7 140 5.3 83 3.8 6 6.625 6.50 17.2 3.50 10.8 6.25 @ 12.2 2.00 7.0 10.75 30.4 5.50 17.4 150 168.3 165 7.8 89 4.9 159 5.5 51 3.2 273 13.8 140 7.9 159.0 mm 6.250 6.50 18.6 3.50 10.8 ————————159.0 165 8.4 89 4.9 165.1 mm 6.500 6.50 15.5 3.50 9.8 3.13 11.4 2.00 7.4 10.75 29.0 5.50 19.0 165.1 165 7.0 89 4.4 79 5.2 51 3.4 273 13.2 140 8.6 07.01_4 Grooved End Fittings 07.01IPS CARBON STEEL PIPE - GROOVED FITTINGS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_L NO. 20 TEENO. 10 ELBOW C to E C to E NO. 10 C to E NO. 11 C to E E to E NO. 12 C to E NO. 13 C to E NO. 100 C to E NO. 110 Size No. 10 90º Elbow No. 11 45º Elbow No. 12 22½° Elbow (sw) No. 13 11¼° Elbow (sw) No. 100† 90° Long Radius Elbow (S) No. 110† 45° Long Radius Elbow (S) Nominal Size Inches mm Actual Outside Dia. Inches mm C to E Inches mm Approx. Wgt. Each Lbs. kg C to E Inches mm Approx. Wgt. Each Lbs. kg C to E Inches mm Approx. Wgt. Each Lbs. kg C to E Inches mm Approx. Wgt. Each Lbs. kg C to E Inches mm Approx. Wgt. Each Lbs. kg C to E Inches mm Approx. Wgt. Each Lbs. kg 8 8.625 7.75 29.9 4.25 20.4 7.75 @ 20.0 2.00 10.1 14.25 66.0 7.25 36.0 200 219.1 197 13.6 108 9.3 197 9.1 51 4.6 362 30.0 184 16.3 10 10.750 9.00 63.3 4.75 37.5 4.38 sw 30.0 2.13 sw 11.8 15.00 107.0 6.25 57.0 250 273.0 229 28.7 121 17.0 111 13.6 54 5.3 381 48.5 159 25.9 12 12.750 10.00 74.0 5.25 66.7 4.88 sw 40.0 2.25 sw 29.3 18.00 156.0 7.50 90.0 300 323.9 254 33.6 133 30.3 124 18.1 57 13.3 457 70.8 191 40.8 14 # 14.000 14.00 136.0 5.75 65.0 5.00 sw 46.0 3.50 sw 32.0 21.00 s 164.0 8.75 s 82.0 350 355.6 355.6 61.7 146 29.5 127 20.9 89 14.5 533 74.4 222 37.2 377.0 mm †14.843 14.84 149.3 6.15 82.0 ————————377.0 376.9 67.7 156.2 37.2 16 # 16.000 16.00 171.0 6.63 88.0 5.00 sw 58.0 4.00 sw 42.0 24.00 s 210.0 10.00 s 100.0 400 406.4 406.4 77.6 168 39.9 127 26.3 102 19.1 610 95.3 254 45.4 426.0 mm †16.772 16.77 198.6 6.95 101.3 ————————426.0 426.0 90.1 176.5 45.9 18 # 18.000 18.00 228.0 7.46 108.0 5.50 sw 65.0 4.50 sw 53.2 27.00 s 273.0 11.25 s 135.0 450 457.0 457.2 103.4 189 50.0 140 29.5 114 24.1 686 123.8 286 61.2 480.0 mm †18.898 18.90 291.0 7.83 141.7 ————————480.0 480.0 132.0 198.8 64.3 20 # 20.000 20.00 298.0 8.28 138.0 6.00 sw 78.6 5.00 sw 65.0 30.00 s 343.0 12.50 s 174.0 500 508.0 508.0 135.2 210 62.6 152 36.0 127 29.5 762 155.6 318 78.9 530.0 mm †20.866 20.87 355.0 8.64 179.0 ————————530.0 530.0 161.0 219.4 81.2 24 # 24.000 24.00 438.0 9.94 221.0 7.00 sw 140.0 6.00 sw 60.0 36.00 s 516.0 15.00 s 251.0 550 610.0 609.6 198.7 252 100.2 178 63.5 152 27.2 914 234.1 381 113.9 630.0 mm †24.803 24.80 545.0 10.27 255.2 ————————630.0 630.0 247.2 261.0 115.7 14 – 24 350 – 600 TM For AGS fitting information, see publication 20.05 @ Gooseneck design, end-to-end dimension * (sw) Segmentally welded steel # For use on cut grooved systems only. For roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales office. † Chinese standard sizes 07.01_5 Grooved End Fittings 07.01IPS CARBON STEEL PIPE - GROOVED FITTINGS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_L NO. 20 TEENO. 10 ELBOW Long Radius Elbow 3D With added wall thickness at bend for abrasive services. NO. 100-3D 90º Long Radius Elbow 3D NO. 110-3D 45º Long Radius Elbow 3D (Ductile Iron) C to E NO. 100-3D C to E NO. 110-3D Size Wall Thickness – Inches/mm No. 100-3D 90º Long Radius Elbow No. 110-3D 45º Long Radius Elbow Nominal Size Inches mm Actual Outside Diameter Inches mm In Non-critical Area At Back Wear Area Extra C to E Inches mm Approx. Weight Each Lbs. kg C to E Inches mm Approx. Weight Each Lbs. kg 2 2.375 0.184 0.309 0.125 10.00 5.0 6.50 4.7 50 60.3 4.67 7.85 3.18 254 2.3 165 2.1 3 3.500 0.246 0.371 0.125 13.00 16.0 7.75 10.4 80 88.9 6.25 9.42 3.18 330 7.3 197 4.7 4 4.500 0.267 0.455 0.188 16.00 25.5 9.00 17.2 100 114.3 6.78 11.56 4.78 406 11.6 229 7.8 6 6.625 0.310 0.560 0.250 24.00 70.0 13.50 45.0 150 168.3 7.87 14.22 6.35 610 31.8 343 20.4 Reducing Base Support Elbow NO. R-10G Grv. × Grv. NO. R-10F Grv. × Flange (Ductile Iron) C to E H B Dia. NO. R-10G C to E H B Dia. NO. R-10F Size No. R-10 Reducing Base Support Elbow Approx. Weight Each Nominal Size Inches mm C to E Inches mm H Inches mm B Diameter Inches mm Grv. × Grv. Lbs. kg Grv. × Flange Lbs. kg 6 × 49.00 1.25 1.50 19.0 33.0 150 100 229 32 38 8.6 15.0 5 9.00 1.50 1.50 23.0 38.0 125 229 38 38 10.4 17.2 8 × 6 10.50 2.13 1.50 33.0 52.0 200 150 267 54 38 15.0 23.6 10 × 8 12.00 2.40 1.50 61.0 88.0 250 200 305 61 38 27.7 39.9 07.01_6 Grooved End Fittings 07.01IPS CARBON STEEL PIPE - GROOVED FITTINGS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_L NO. 20 TEENO. 10 ELBOW Adapter Elbow NO. 18 90º Adapter Elbow NO. 19 45º Adapter Elbow (Ductile Iron)C to TE C to GE NO. 18 C to GE C to TE NO. 19 Size No. 18 90° Adapter Elbow @ No. 19 45° Adapter Elbow @ Nominal Size Inches mm Actual Outside Diameter Inches mm C to GE Inches mm C to TE Inches mm Approx. Weight Each Lbs. kg C to GE Inches mm C to TE Inches mm Approx. Weight Each Lbs. kg ¾ 1.050 2.25 2.25 0.5 1.50 1.50 0.5 20 26.9 57 57 0.2 38 38 0.2 1 1.315 2.25 2.25 0.5 1.75 1.75 0.6 25 33.7 57 57 0.2 44 44 0.3 1 ¼ 1.660 2.75 2.75 0.9 1.75 1.75 0.6 32 42.4 70 70 0.4 44 44 0.3 1 ½ 1.900 2.75 2.75 1.1 1.75 1.75 0.9 40 48.3 70 70 0.5 44 44 0.4 2 2.375 3.25 4.25 2.5 2.00 3.00 1.9 50 60.3 83 108 1.1 51 76 0.9 2 ½ 2.875 3.75 3.75 3.0 2.25 2.25 2.3 65 73.0 95 95 1.4 57 57 1.0 3 3.500 4.25 6.00 5.8 2.50 4.25 5.0 80 88.9 108 152 2.6 64 108 2.3 3 ½ 4.000 4.50 6.25 8.0 5.25 5.25 8.8 90 101.6 114 159 3.6 133 133 4.0 4 4.500 5.00 7.25 12.0 3.00 5.25 8.8 100 114.3 127 184 5.4 76 133 4.0 6 6.625 6.50 6.50 17.6 3.50 3.50 12.7 150 168.3 165 165 8.0 89 89 5.8 @ Available with British Standard Pipe Threads, specify “BSP” clearly on order. + Contact Victaulic for details. 07.01_7 Grooved End Fittings 07.01IPS CARBON STEEL PIPE - GROOVED FITTINGS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_L NO. 20 TEENO. 10 ELBOW C to E C to E NO. 20 C to E NO 35 C to LE C to SE NO. 33 C to GE C to TE NO. 29M Size No. 20 Tee No. 35 Cross (sw) No. 33 True Wye (sw) No. 29M Tee with Threaded Branch Nominal Size Inches mm Actual Outside Dia. Inches mm C to E Inches mm Approx. Weight Each Lbs. kg C to E Inches mm Approx. Weight Each Lbs. kg C to LE Inches mm C to SE Inches mm Approx. Weight Each Lbs. kg C to GE Inches mm C to TE Inches mm Approx. Weight Each Lbs. kg ¾ 1.050 2.25 0.6 2.25 0.9 ———2.25 2.25 0.6 20 26.9 57 0.3 57 0.4 57 57 0.3 1 1.315 2.25 1.0 2.25 1.3 2.25 2.25 1.1 2.25 2.25 1.0 25 33.7 57 0.5 57 0.6 57 57 0.5 57 57 0.5 1 ¼ 1.660 2.75 1.5 2.75 2.1 2.75 2.50 1.5 2.75 2.75 1.5 3242.4700.7701.070640.770700.7 1 ½ 1.900 2.75 2.0 2.75 2.5 2.75 2.75 1.8 2.75 2.75 2.0 40 48.3 70 0.9 70 1.1 70 70 0.8 70 70 0.9 2 2.375 3.25 3.0 3.25 3.8 3.25 2.75 2.5 3.25 4.25 3.00 50 60.3 83 1.4 83 1.7 83 70 1.1 83 108 1.4 2 ½ 2.875 3.75 4.3 3.75 6.1 3.75 3.00 4.3 3.75 3.75 4.3 65 73.0 95 2.0 95 2.8 95 76 2.0 95 95 2.0 76.1 mm 3.000 3.75 5.2 —————3.75 3.75 5.2 (sw) 76.1 95 2.4 95 95 2.4 3 3.500 4.25 6.8 4.25 10.5 4.25 3.25 6.1 4.25 6.00 6.8 80 88.9 108 3.0 108 4.8 108 83 2.8 108 152 3.1 3 ½ 4.000 4.50 (sw) 7.9 4.50 11.5 4.50 3.50 9.6 4.50 4.50 7.9 (sw) 90 101.6 114 3.6 114 5.2 114 89 4.4 114 114 73.6 108.0 mm 4.250 5.00 15.5 —————5.00 5.00 15.5 108.0 127 7.0 127 127 7.0 4 4.500 5.00 11.9 5.00 15.8 5.00 3.75 10.0 5.00 7.25 11.9 100 114.3 127 5.4 127 7.2 127 95 4.5 127 184 5.4 4 ½ 5.000 5.25 (sw) 15.0 5.25 18.5 ———5.25 5.25 15.0 (sw) 120 127.0 133 6.8 133 8.4 133 133 6.8 133.0 mm 5.250 5.50 17.8 —————5.50 5.50 17.8 133.0 140 8.1 140 140 8.1 139.7 mm 5.500 5.50 17.8 —————5.50 5.50 17.8 139.7 140 8.1 140 140 8.1 5 5.563 5.50 17.8 5.50 20.0 5.50 4.00 15.0 5.50 5.50 17.8 (sw) 125 141.3 140 8.1 140 9.1 140 102 6.8 140 140 8.1 159.0 mm 6.250 6.50 27.1 —————6.50 6.50 27.1 159.0 165 12.3 165 165 12.3 165.1 mm 6.5006.5022.06.5028.0 ———6.50 6.50 22.0 165.1 165 10.0 165 12.7 165 165 10.0 6 6.625 6.50 25.7 6.50 28.0 6.50 4.50 22.3 6.50 6.50 25.7 (sw) 150 168.3 165 11.7 165 12.7 165 114 10.1 165 165 11.7 8 8.625 7.75 47.6 7.75 48.0 7.75 6.00 36.0 7.75 7.75 47.6 (sw) 200 219.1 197 21.6 197 21.8 197 152 16.3 197 197 21.6 10 10.750 9.00 99.0 9.00 121.5 9.00 6.50 69.9 9.00 9.00 73.0 250 273.0 229 44.9 229 55.1 229 155 31.7 229 229 33.1 12 12.750 10.00 133.0 10.00 110.0 10.00 7.00 80.0 10.00 10.00 99.0 300 323.9 254 60.3 254 49.9 254 178 36.3 254 254 44.9 Tees, Crosses and True Wyes NO. 20 Tee NO. 35 Cross NO. 33 True Wye NO. 29M Tee with Threaded Branch (Ductile Iron *) Tees, Crosses and True Wyes NO. 20 Tee NO. 35 Cross NO. 33 True Wye NO. 29M Tee with Threaded Branch (Ductile Iron *) 07.01_8 Grooved End Fittings 07.01IPS CARBON STEEL PIPE - GROOVED FITTINGS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_L NO. 20 TEENO. 10 ELBOW C to E C to E NO. 20 C to E NO 35 C to LE C to SE NO. 33 C to GE C to TE NO. 29M Size No. 20 Tee No. 35 Cross (sw) No. 33 True Wye (sw) No. 29M Tee with Threaded Branch Nominal Size Inches mm Actual Outside Dia. Inches mm C to E Inches mm Approx. Weight Each Lbs. kg C to E Inches mm Approx. Weight Each Lbs. kg C to LE Inches mm C to SE Inches mm Approx. Weight Each Lbs. kg C to GE Inches mm C to TE Inches mm Approx. Weight Each Lbs. kg 14 # 14.000 11.00 145.0 11.00 198.0 11.00 7.50 134.2 ———350 355.6 279 65.8 279 89.8 279 191 60.8 377.0 mm 14.000 11.00 145.0 ————————355.6 279 65.8 16 # 16.000 12.00 186.0 12.00 250.0 12.00 8.00 167.0 ———400 406.4 305 84.4 305 113.4 305 203 75.7 426.0 mm †16.000 12.00 186.0 ————————406.4 305 84.4 18 # 18.000 14.00 256.0 15.50 350.0 15.50 8.50 234.0 ———450 457.0 356 116.1 394 158.8 394 216 106.1 480.0 mm†18.000 14.00 256.0 ————————457.0 356 116.1 20 # 20.000 15.00 339.0 17.25 452.0 17.25 9.00 281.0 ———500 508.0 381 153.8 438 205.0 438 229 127.5 530.0 mm †20.000 15.00 339.0 ————————508.0 381 153.8 24 # 24.000 17.00 473.0 20.00 795.0 20.00 10.00 523.0 ———550 610.0 432 214.5 508 360.6 508 254 237.2 630.0 mm †24.000 17.00 473.0 ————————610.0 432 214.5 14 – 24 350 – 600 TM For AGS fitting information, see publication 20.05 * (sw) Segmentally welded steel # For use on cut grooved systems only. For roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales office. † Chinese standard sizes IMPORTANT NOTE: Fittings size 26 – 48"/650 – 1050 mm are available roll grooved for installation with Style 770 large diameter pipe couplings, Contact Victaulic for details. Tees, Crosses and True Wyes NO. 20 Tee NO. 35 Cross NO. 33 True Wye NO. 29M Tee with Threaded Branch (Ductile Iron *) Tees, Crosses and True Wyes NO. 20 Tee NO. 35 Cross NO. 33 True Wye NO. 29M Tee with Threaded Branch (Ductile Iron *) 07.01_9 Grooved End Fittings 07.01IPS CARBON STEEL PIPE - GROOVED FITTINGS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_L NO. 20 TEENO. 10 ELBOW Size No. 25 Std. No. 29 w/ Thd. Branch Approx. Weight Each Nominal Size Inches mm C to E Inches mm C to E Inches mm Lbs. kg 1 × 1 × ¾ ++1.0 25 20 0.5 1 ¼ × 1 ¼ × 1 ++1.3 32 32 25 0.6 1 ½ × 1 ½ × ¾ ++1.5 40 40 20 0.7 1 ++1.5 25 0.7 1 ¼ ++1.7 32 0.8 2 × 2 × ¾ 3.25 3.25 2.5 50 50 20 83 83 1.1 1 3.25 3.25 2.7 25 83 83 1.2 1 ¼ ++1.8 32 0.8 1 ½ 3.25 3.25 (sw) 3.0 40 83 83 1.4 2 ½ × 2 1⁄2 × ¾ ++3.9 65 65 20 1.8 1 3.75 3.75 (sw) 3.8 25 95 95 1.7 1 ¼ ++4.2 32 1.7 1 ½ 3.75 3.75 3.9 40 95 95 1.8 2 3.75 3.75 (sw) 4.5 50 95 95 2.0 3 × 3 × ¾ ++5.7 80 80 20 2.6 1 4.25 4.25 6.1 25 108 108 2.8 1 ¼ ++8.0 32 3.6 1 ½ 4.25 4.25 (sw) 6.5 40 108 108 2.9 2 4.25 4.25 (sw) 6.2 50 108 108 2.8 2 ½ 4.25 4.25 (sw) 6.4 65 108 108 2.9 4 × 4 × ¾ ++8.0 100 100 20 3.6 1 5.00 5.00 7.8 25 127 127 3.5 C to E C to E NO. 25 C to E C to E NO. 29 Size No. 25 Std. No. 29 w/ Thd. Branch Approx. Weight Each Nominal Size Inches mm C to E Inches mm C to E Inches mm Lbs. kg 4 × 4 × 1 ¼ ++9.6 100 100 32 4.4 1 ½ 5.00 5.00 10.2 40 127 127 4.6 2 5.00 5.00 11.2 50 127 127 5.1 2 ½ 5.00 5.00 11.4 65 127 127 5.2 3 5.00 5.00 11.6 80 127 127 5.3 5 × 5 × 1 ++14.0 125 125 25 6.4 1 ½ ++14.3 40 6.5 2 5.50 (sw) 5.50 (sw) 14.5 50 140 140 6.6 2 ½ 5.50 5.50 (sw) 15.2 65 140 140 6.9 3 5.50 5.50 (sw) 16.6 80 140 140 7.5 4 5.50 5.50 (sw) 16.7 100 140 140 7.6 6 × 6 × 1 ++23.0 150 150 25 10.4 1 ½ ++24.0 40 10.9 2 6.50 6.50 21.6 50 165 165 9.8 2 ½ 6.50 6.50 21.4 65 165 165 11.7 14 – 24 350 – 600 TM For AGS fitting information, see publication 20.05 + Contact Victaulic for details. * Ductile iron except those that are marked (sw), which are segmentally welded steel. # For use on cut grooved systems only. For roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales office. IMPORTANT NOTE: No. 29 Threaded Outlet Reducing Tees are supplied NPT and are available with British Standard threads. For British Standard specify "BSP" clearly on order. Reducing Tee NO. 25 Grooved Branch NO. 29 Threaded Branch (Ductile Iron*) 07.01_10 Grooved End Fittings 07.01IPS CARBON STEEL PIPE - GROOVED FITTINGS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_L NO. 20 TEENO. 10 ELBOW C to E C to E NO. 25 C to E C to E NO. 29 Size No. 25 Std. No. 29 w/ Thd. Branch Approx. Weight Each Nominal Size Inches mm C to E Inches mm C to E Inches mm Lbs. kg 6 × 6 × 3 6.50 6.50 26.5 150 150 80 165 165 12.0 4 6.50 6.50 25.0 100 165 165 11.3 5 6.50 6.50 23.2 125 165 165 10.5 6 ½ × 6 ½ × 3 6.50 6.50 (sw) 24.0 165.1 165.1 80 165 165 10.9 4 6.50 6.50 (sw) 25.0 100 165 165 11.3 8 × 8 × 1 ½ ++33.0 200 200 40 15.0 2 7.75 (sw) 7.75 (sw) 33.5 50 197 197 15.2 2 ½ ++39.0 65 17.7 3 7.75 (sw) 7.75 (sw) 33.6 80 197 197 15.2 4 7.75 7.75 41.8 100 197 197 19.0 5 7.75 (sw) 7.75 (sw) 34.0 125 197 197 15.4 6 7.75 7.75 42.3 150 197 197 19.2 165.1 7.75 (sw) 7.75 (sw) 48.0 197 197 21.8 10 × 10 × 1 ½ ++62.0 250 250 40 28.1 2 9.00 (sw) 9.00 (sw) 62.0 50 229 229 28.1 2 ½ ++62.4 65 28.3 3 ++60.0 80 27.2 4 9.00 (sw) 9.00 (sw) 61.0 100 229 229 27.7 5 9.00 (sw) 9.00 (sw) 52.0 125 229 229 23.6 6 9.00 (sw) 9.00 (sw) 59.0 150 229 229 26.8 8 9.00 (sw) 9.00 (sw) 64.7 200 229 229 29.3 C to E C to E NO. 25 C to E C to E NO. 29 Size No. 25 Std. No. 29 w/ Thd. Branch Approx. Weight Each Nominal Size Inches mm C to E Inches mm C to E Inches mm Lbs. kg 12 × 12 × 1 ++77.0 300 300 25 34.9 2 ++80.0 50 36.3 2 ½ ++78.0 65 35.4 3 10.00 (sw) 10.00 (sw) 82.0 80 254 254 37.2 4 10.00 (sw) 10.00 (sw) 80.0 100 254 254 36.3 5 10.00 (sw) 10.00 (sw) 75.0 125 254 254 34.0 6 10.00 (sw) 10.00 (sw) 75.0 150 254 254 34.0 8 10.00 (sw) 10.00 (sw) 80.0 200 254 254 36.3 10 10.00 (sw) 10.00 (sw) 84.0 250 254 254 38.1 # 14 × 14 × 4 ++102.0 350 350 100 46.3 6 ++108.2 150 49.1 8 11.00 11.00 112.0 200 279 279 50.8 10 11.00 11.00 120.0 300 279 279 54.4 12 11.00 11.00 129.1 300 279 279 58.6 # 16 × 16 × 4 ++130.0 400 400 100 59.0 14 – 24 350 – 600 TM For AGS fitting information, see publication 20.05 + Contact Victaulic for details. * Ductile iron except those that are marked (sw), which are segmentally welded steel. # For use on cut grooved systems only. For roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales office. IMPORTANT NOTE: No. 29 Threaded Outlet Reducing Tees are supplied NPT and are available with British Standard threads. For British Standard specify "BSP" clearly on order. Reducing Tee NO. 25 Grooved Branch NO. 29 Threaded Branch (Ductile Iron *) 07.01_11 Grooved End Fittings 07.01IPS CARBON STEEL PIPE - GROOVED FITTINGS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_L NO. 20 TEENO. 10 ELBOW C to E C to E NO. 25 C to E C to E NO. 29 Size No. 25 Std. No. 29 w/ Thd. Branch Approx. Weight Each Nominal Size Inches mm C to E Inches mm C to E Inches mm Lbs. kg # 16 × 16 × 6 ++133.5 400 400 150 60.6 812.00 12.00 145.0 200 305 305 65.8 10 12.00 12.00 149.5 250 305 305 67.8 12 12.00 12.00 154.0 300 305 305 69.9 14 ++167.0 350 75.8 # 18 × 18 × 4 ++194.0 450 450 100 88.0 6 ++200.0 150 90.7 8 ++202.0 200 91.6 10 15.50 15.50 212.0 250 394 394 96.2 12 15.50 15.50 222.6 300 394 394 101.0 14 15.50 – 230.1 350 394 – 104.4 16 15.50 – 247.6 400 394 – 112.3 # 20 × 20 × 6 ++240.0 500 500 150 108.9 8 ++244.0 200 110.7 10 ++256.0 250 116.1 12 ++264.0 300 119.8 14 17.25 —275.0 350 438 124.7 C to E C to E NO. 25 C to E C to E NO. 29 Size No. 25 Std. No. 29 w/ Thd. Branch Approx. Weight Each Nominal Size Inches mm C to E Inches mm C to E Inches mm Lbs. kg # 20 × 20 16 17.25 —288.6 500 500 400 438 130.9 18 17.25 —297.0 450 438 134.7 # 24 × 24 × 820.00 20.00 340.0 600 600 200 508 508 154.2 10 20.00 20.00 343.9 250 508 508 156.0 12 20.00 20.00 352.8 300 508 508 160.0 14 § 20.00 —360.0 350 508 163.3 16 20.00 —378.0 400 508 171.5 18 § 20.00 —380.0 450 508 172.4 20 20.00 —373.0 500 508 169.2 14 – 24 350 – 600 TM For AGS fitting information, see publication 20.05 + Contact Victaulic for details. * Ductile iron except those that are marked (sw), which are segmentally welded steel. # For use on cut grooved systems only. For roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales office. IMPORTANT NOTE: No. 29 Threaded Outlet Reducing Tees are supplied NPT and are available with British Standard threads. For British Standard specify "BSP" clearly on order. § Cast fitting available. Contact Victaulic for details. Reducing Tee NO. 25 Grooved Branch NO. 29 Threaded Branch (Ductile Iron *) 07.01_12 Grooved End Fittings 07.01IPS CARBON STEEL PIPE - GROOVED FITTINGS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_L NO. 20 TEENO. 10 ELBOW Standpipe Tee NO. 27 (Ductile iron) C to EOB C to EOR NO. 27 Size No. 27 Standpipe Tee Nominal Size Inches mm C to EOR Inches mm C to EOB Inches mm Approx. Weight Each Lbs. kg 4 × 4 × 2 ½ 3.25 4.00 9.1 100 100 65 83 102 4.1 6 × 6 × 2 ½ 3.25 5.13 14.8 150 150 65 83 130 6.7 IMPORTANT NOTE: Available with British Standard Pipe Threads, specify “BSP” clearly on order. Bullhead Tee NO. 21 (Ductile Iron) C to EOB C to EOR NO. 21 Size No. 21 Bullhead Tee Nominal Size Inches mm C to EOR Inches mm C to EOB Inches mm Approx. Weight Each Lbs. kg 5 × 5 × 87.75 5.50 28.7 125 125 200 197 140 13.0 6 × 6 × 87.75 6.50 37.5 150 150 200 197 165 17.0 Bull Plug NO. 61 (Steel) E to E NO. 61 Size No. 61 Bull Plug Nominal Size Inches mm Actual Outside Diameter Inches mm E to E Inches mm Approx. Weight Each Lbs. kg 22.3754.002.5 50 60.3 102 1.1 2 ½ 2.875 5.00 3.0 65 73.0 127 1.4 3 3.500 6.00 4.5 80 88.9 152 2.0 4 4.500 7.00 7.5 100 114.3 178 3.4 55.5638.0012.0 125 141.3 203 5.4 66.62510.0017.0 150 168.3 254 7.7 IMPORTANT NOTES: Steel dish caps available through 24"/600 mm, contact Victaulic. No. 61 Bull Plugs should be used in vacuum service with Style 72 or 750 couplings 07.01_13 Grooved End Fittings 07.01IPS CARBON STEEL PIPE - GROOVED FITTINGS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_L NO. 20 TEENO. 10 ELBOW 45° Lateral NO. 30 (Segmentally Welded Steel) C t o L E C to LE C to SE NO. 30 Size No. 30 45º Lateral Nominal Size Inches mm Actual Outside Diameter Inches mm C to LE Inches mm C to SE Inches mm Approx. Weight Each Lbs. kg ¾ 1.050 4.50 2.00 1.0 20 26.9 114 51 0.5 11.3155.002.251.7 25 33.7 127 57 0.8 1 ¼ 1.660 5.75 2.50 2.5 (d) 32 42.4 146 64 1.1 1 ½ 1.900 6.25 2.75 3.5 40 48.3 159 70 1.6 2 2.375 7.00 2.75 4.6 (d) 50 60.3 178 70 2.1 2 ½ 2.875 7.75 3.00 9.0 65 73.0 197 76 94.1 76.1 mm 3.000 8.50 3.25 11.0 76.1 216 83 5.0 33.5008.503.2511.7 (d) 80 88.9 216 83 5.4 3 ½ 4.000 10.00 3.50 17.8 90 101.6 254 89 8.1 4 4.500 10.50 3.75 22.2 (d) 100 114.3 267 95 10.1 55.56312.504.0021.8 125 141.3 318 102 9.9 165.1 mm 6.500 14.00 4.50 43.6 165.1 356 114 19.8 45° Lateral NO. 30 (Segmentally Welded Steel) C t o L E C to LE C to SE NO. 30 Size No. 30 45º Lateral Nominal Size Inches mm Actual Outside Diameter Inches mm C to LE Inches mm C to SE Inches mm Approx. Weight Each Lbs. kg 66.62514.004.5043.6 150 168.3 356 114 19.8 8 8.625 18.00 6.00 72.0 200 219.1 457 152 32.7 10 10.750 20.50 6.50 105.0 250 273.0 521 165 47.6 12 12.750 23.00 7.00 165.0 300 323.9 584 178 74.8 14 # 14.000 26.50 7.50 276.0 350 355.6 673 191 125.2 16 # 16.000 29.00 8.00 344.2 400 406.4 737 203 156.1 18 # 18.000 32.00 8.50 429.0 450 457.0 813 216 194.6 20 # 20.000 35.00 9.00 500.0 500 508.0 889 229 226.8 24 # 24.000 40.00 10.00 715.0 600 610.0 1016 254 324.3 14 – 24 350 – 600 TM For AGS fitting information, see publication 20.05 (d) Ductile iron # For use on cut grooved systems only. For roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales office. 07.01_14 Grooved End Fittings 07.01IPS CARBON STEEL PIPE - GROOVED FITTINGS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_L NO. 20 TEENO. 10 ELBOW 45º Reducing Lateral NO. 30-R (Segmentally Welded Steel) C t o L E C to LE C to SE NO. 30-R Size No. 30-R 45º Reducing Lateral Nominal Size Inches mm C to LE Inches mm C to SE Inches mm Approx. Weight Each Lbs. kg 3 x 3 x 28.50 3.25 9.8 80 80 50 216 83 4.4 2 1⁄2 8.50 3.25 9.8 65 216 83 4.4 4 x 4 x 210.50 3.75 10.0 100 100 50 267 95 4.5 2 ½ 10.50 3.75 10.0 65 267 95 4.5 310.50 3.75 18.3 80 267 95 8.3 5 x 5 x 212.50 4.00 24.0 125 125 50 318 102 10.9 312.50 4.00 27.0 80 318 102 212.2 412.50 4.00 26.5 100 318 102 12.0 6 x 6 x 3 14.00 4.50 37.0 150 150 80 356 114 16.8 4 14.00 4.50 36.0 100 356 114 16.3 5 14.00 4.50 44.7 125 356 114 20.3 8 x 8 x 418.00 6.00 62.0 200 200 100 457 152 28.1 518.00 6.00 75.5 125 457 152 34.2 618.00 6.00 82.0 150 457 152 37.2 10 x 10 x 4 20.50 6.50 104.8 250 250 100 521 165 147.5 5 20.50 6.50 99.0 125 521 165 44.9 6 20.50 6.50 105.8 150 521 165 48.0 8 20.50 6.50 118.0 200 521 165 53.5 12 x 12 x 5 23.00 7.00 122.0 300 300 125 584 178 55.3 6 23.00 7.00 137.0 150 584 178 62.1 8 23.00 7.00 147.0 200 584 178 66.7 10 23.00 7.00 167.0 250 584 178 75.8 45º Reducing Lateral NO. 30-R (Segmentally Welded Steel) C t o L E C to LE C to SE NO. 30-R Size No. 30-R 45º Reducing Lateral Nominal Size Inches mm C to LE Inches mm C to SE Inches mm Approx. Weight Each Lbs. kg # 14 x 14 x 4 26.50 7.50 172.0 350 350 100 673 191 78.0 6 26.50 7.50 187.0 150 673 191 84.8 8 26.50 7.50 205.8 200 673 191 93.4 10 26.50 7.50 235.0 250 673 191 106.6 12 26.50 7.50 250.0 300 673 191 113.4 # 16 x 16 x 629.00 8.00 215.0 400 400 150 737 203 97.5 829.00 8.00 252.5 200 737 203 114.5 10 29.00 8.00 265.0 250 737 203 120.2 12 29.00 8.00 295.0 300 737 203 133.8 14 29.00 8.00 305.0 350 737 203 138.3 # 18 x 18 x 632.00 8.50 274.0 450 450 150 813 216 124.3 832.00 8.50 275.0 200 813 216 124.7 12 32.00 8.50 347.0 300 813 216 157.4 14 32.00 8.50 350.0 350 813 216 158.8 16 32.00 8.50 362.0 400 813 216 164.2 # 20 x 20 x 12 35.00 9.00 415.0 500 500 300 889 229 188.2 14 35.00 9.00 420.0 350 889 229 190.5 16 35.00 9.00 425.0 400 889 229 192.8 # 24 x 24 x 16 40.00 10.00 425.0 600 600 400 1016 254 192.8 20 40.00 10.00 570.0 600 1016 254 258.6 14 – 24 350 – 600 TMFor AGS fitting information, see publication 20.05 # For use on cut grooved systems only. For roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales office. 07.01_15 Grooved End Fittings 07.01IPS CARBON STEEL PIPE - GROOVED FITTINGS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_L NO. 20 TEENO. 10 ELBOW Tee Wye NO. 32 (Segmentally Welded Steel)H G E2 E1 NO. 32 Size No. 32 Tee Wye Nominal Size Inches mm G Inches mm H Inches mm E 1 Inches mm E 2 Inches mm Approx. Wgt. Each Lbs. kg 2 × 2 × 2 2.75 7.00 9.00 4.63 6.4 50 50 50 70 178 229 118 2.9 2 ½ × 2 ½ × 2 ½ 3.00 7.75 10.50 5.75 11.5 65 65 65 76 197 267 146 5.2 3 × 3 × 33.258.5011.506.5014.3 80 80 80 83 216 292 165 6.5 3 ½ × 3 ½ × 3 ½ 3.25 10.00 13.00 7.75 22.9 90 90 90 89 254 330 197 10.4 4 × 4 × 3 3.75 10.50 12.88 7.88 23.0 100 100 80 95 267 327 200 10.4 43.7510.5013.638.13 26.0 100 95 267 346 207 11.8 5 × 5 × 3 4.00 12.50 14.25 9.25 29.0 125 125 80 102 318 362 235 13.2 44.0012.5015.139.6336.7 100 102 318 384 245 16.6 54.0012.5016.1310.0048.0 125 102 318 410 254 21.8 6 × 6 × 34.5014.0015.3110.3137.3 150 150 80 114 356 389 262 16.9 44.5014.0016.2510.7546.3 100 114 356 413 273 21.0 54.5014.0017.2511.1355.0 125 114 356 438 283 24.9 6 4.50 14.00 18.25 11.50 60.5 150 114 356 464 292 27.4 Tee Wye NO. 32 (Segmentally Welded Steel)H G E2 E1 NO. 32 Size No. 32 Tee Wye Nominal Size Inches mm G Inches mm H Inches mm E 1 Inches mm E 2 Inches mm Approx. Wgt. Each Lbs. kg 8 × 8 × 36.0018.0018.1913.1976.0 200 200 80 152 457 462 335 34.5 4 6.00 18.00 19.00 13.50 76.4 100 152 457 483 343 34.7 56.0018.0020.0013.8885.6 125 152 457 508 352 38.8 66.0018.0021.1314.38112.0 150 152 457 537 365 50.8 86.0018.0023.2515.25127.1 200 152 457 591 387 57.7 10 × 10 × 36.5020.5019.8814.8896.0 250 250 80 165 521 505 378 43.5 46.5020.5020.7515.2597.4 100 165 521 527 387 44.2 5 6.50 20.50 21.88 15.75 115.0 125 165 521 556 400 52.2 10 × 10 × 6 6.50 20.50 22.88 16.13 133.1 250 250 150 165 521 581 410 60.4 86.5020.5027.2519.25156.0 200 165 521 692 489 70.8 10 6.50 20.50 27.25 18.00 190.0 250 165 521 692 457 186.2 12 × 12 × 12 7.00 23.00 31.00 20.50 240.0 300 300 300 178 584 787 521 108.9 07.01_16 Grooved End Fittings 07.01IPS CARBON STEEL PIPE - GROOVED FITTINGS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_L NO. 20 TEENO. 10 ELBOW Reducing Tee Wye NO. 32-R (Segmentally Welded Steel)H G E2 E1 NO. 32-R Size No. 32-R Reducing Tee Wye Nominal Size Inches mm G Inches mm H Inches mm E1 Inches mm E 2 Inches mm Approx. Wgt. Each Lbs. kg 4 × 3 × 3 3.50 9.50 10.75 5.75 16.0 100 80 80 89 241 273 146 7.3 43.7510.5013.638.13 16.0 100 95 267 346 206 7.3 5 × 3 × 31.259.7511.507.63 25.0 125 80 80 32 248 292 194 11.3 54.0012.5016.1311.1343.4 125 102 318 410 283 19.5 5 × 4 × 31.889.1311.886.88 21.0 125 100 80 48 232 302 175 9.5 41.889.1312.757.25 25.0 100 48 232 324 184 11.3 Reducing Tee Wye NO. 32-R (Segmentally Welded Steel)H G E2 E1 NO. 32-R Size No. 32-R Reducing Tee Wye Nominal Size Inches mm G Inches mm H Inches mm E1 Inches mm E 2 Inches mm Approx. Wgt. Each Lbs. kg 6 × 4 × 64.5014.0018.2511.5061.0 150 100 150 114 356 464 292 27.7 6 × 5 × 3 1.25 10.75 13.00 8.00 27.0 150 125 80 32 273 330 203 12.2 41.2510.7513.888.38 31.0 100 32 273 352 213 14.1 8 × 6 × 41.0012.0014.759.25 45.0 200 150 100 25 304 375 235 20.4 86.0018.0023.2515.25112.0 200 152 457 591 387 50.8 07.01_17 Grooved End Fittings 07.01IPS CARBON STEEL PIPE - GROOVED FITTINGS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_L NO. 20 TEENO. 10 ELBOW Adapter Nipple NO. 40 Grv. × Thd. NO. 42 Grv. × Bev. NO. 43 Grv. × Grv. (Steel) E to E NO. 40 * E to E NO. 42 E to E NO. 43 Size No. 40, 42, 43 Adapter Nipple (sw) Nominal Size Inches mm Actual Outside Diameter Inches mm E to E Inches mm Approx. Weight Each Lbs. kg 3/4 1.050 3.00 0.3 20 26.9 76 0.1 11.3153.000.4 25 33.7 76 0.2 1¼ 1.660 4.00 0.8 32 42.4 102 0.4 1½ 1.900 4.00 0.9 40 48.3 102 0.4 22.3754.001.2 50 60.3 102 0.5 2½ 2.875 4.00 1.9 65 73.0 102 0.9 3 3.500 4.00 2.5 80 88.9 102 1.1 3½ 4.000 4.00 2.1 90 101.6 102 0.9 4 4.500 6.00 5.5 100 114.3 152 2.5 55.5636.007.4 125 141.3 152 3.4 Adapter Nipple NO. 40 Grv. × Thd. NO. 42 Grv. × Bev. NO. 43 Grv. × Grv. (Steel) E to E NO. 40 * E to E NO. 42 E to E NO. 43 Size No. 40, 42, 43 Adapter Nipple (sw) Nominal Size Inches mm Actual Outside Diameter Inches mm E to E Inches mm Approx. Weight Each Lbs. kg 66.6256.009.5 150 168.3 152 4.3 88.6256.0014.2 200 219.1 152 6.4 10 10.750 8.00 27.0 250 273.0 203 12.2 12 12.750 8.00 33.0 300 323.9 203 15.0 * Available with British Standard Pipe Threads, specify “BSP” clearly on order. IMPORTANT NOTES: For pump package nipples with 1 ½"/40 mm hole cut to receive Style 923 Vic-Let or Style 924 Vic-O-Well request special No. 40, 42 or 43 nipples and specify No. 40-H, 42-H or 43-H on order. NOTE: 4 – 12"/100 – 300 mm diameter – 8"/200 mm minimum length required. # For use on cut grooved systems only. For roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales office. 07.01_18 Grooved End Fittings 07.01IPS CARBON STEEL PIPE - GROOVED FITTINGS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_L NO. 20 TEENO. 10 ELBOW Cap NO. 60 (Ductile Iron) T NO. 60 Size No. 60 Cap Nominal Size Inches mm Actual Outside Diameter Inches mm T Thickness Inches mm Approx. Weight Each Lbs. kg 3/4 1.050 0.88 0.2 20 26.9 22 0.1 1 1.315 0.88 0.3 25 33.7 22 0.1 1 1/4 1.660 0.88 0.3 32 42.4 22 0.1 1 1/2 1.900 0.88 0.5 40 48.3 22 0.2 2 2.375 0.88 0.6 50 60.3 22 0.3 2 1/2 2.875 0.88 1.0 65 73.0 22 0.5 76.1 mm 3.000 0.88 1.2 76.1 22 0.5 33.5000.881.2 80 88.9 22 0.5 3 1/2 4.000 0.88 2.5 90 101.6 22 1.1 108.0 mm 4.250 1.00 2.3 108.0 25 1.0 4 4.500 1.00 2.5 100 114.3 25 1.1 4 1/2 5.000 1.00 2.5 120 127.0 25 1.1 133.0 mm 5.250 1.00 4.5 133.0 25 2.0 139.7 mm 5.500 1.00 4.5 139.7 25 2.0 55.5631.004.6 125 141.3 25 2.1 159.0 mm 6.250 1.00 6.8 159.0 25 3.1 Cap NO. 60 (Ductile Iron) T NO. 60 Size No. 60 Cap Nominal Size Inches mm Actual Outside Diameter Inches mm T Thickness Inches mm Approx. Weight Each Lbs. kg 165.1 mm 6.500 1.00 7.3 165.1 25 3.3 66.6251.006.1 150 168.3 25 2.8 88.6251.1913.1 200 219.1 30 5.9 10 10.750 1.25 21.0 250 273.0 32 9.5 12 12.750 1.25 35.6 300 323.9 32 16.2 14 # 14.000 9.50 *350 355.6 241 16 # 16.000 10.00 *400 406.4 254 18 # 18.000 11.00 *450 457.0 279 20 # 20.000 12.00 *500 508.0 305 24 # 24.000 * *600 610.0 14 – 24 350 – 600 TM For AGS fitting information, see publication 20.05 IMPORTANT NOTES: * Steel dish caps available through 24"/600 mm, contact Victaulic. No. 60 cap is not suitable for use in vacuum service with Style 72 or 750 couplings. No. 61 bull plugs should be used, see pg. 35. # For use on cut grooved systems only. For roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales office. 07.01_19 Grooved End Fittings 07.01IPS CARBON STEEL PIPE - GROOVED FITTINGS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_L NO. 20 TEENO. 10 ELBOW Flanged Adapter Nipple NO. 41 ANSI Class 125 (Cast Iron) NO. 45F ANSI Class 150 Flat Face (Steel) NO. 45R ANSI Class 150 Raised Face (Steel) NO. 46F ANSI Class 300 Flat Face (Steel) NO. 46R ANSI Class 300 Raised Face (Steel) E to E NO. 41 E to E NO. 45F E to E NO. 45R E to E NO. 46F E to E NO. 46R Size No. 41 ANSI 125 Flange Adapter Nipple No. 45F and No. 45R ANSI 150 Flange Adapter Nipple No. 46F and No. 46R ANSI 300 Flange Adapter Nipple Nominal Size Inches mm Actual Outside Diameter Inches mm E to E Inches mm Approx. Weight Each Lbs. kg E to E Inches mm Approx. Weight Each Lbs. kg E to E Inches mm Approx. Weight Each Lbs. kg ¾ 1.050 3 —3 2.3 3 3.3 20 26.9 76 76 1.0 76 1.5 11.3153 2.5 3 2.7 3 3.9 25 33.7 76 1.1 76 1.2 76 1.8 1¼ 1.660 4 3.0 4 3.3 4 4.8 32 42.4 102 1.4 102 1.5 102 2.2 1½ 1.900 4 3.5 4 3.9 4 6.9 40 48.3 102 1.6 102 1.8 102 3.1 2 2.375 4 5.5 4 6.2 4 8.2 50 60.3 102 2.5 102 2.8 102 3.7 2½ 2.875 4 8.0 4 9.9 4 11.9 65 73.0 102 3.6 102 4.5 102 5.4 3 3.500 4 9.5 4 11.4 4 16.5 80 88.9 102 4.3 102 5.2 102 7.5 3½ 4.00412.0415.1420.1 90 101.6 102 5.4 102 6.8 102 9.1 44.500616.7618.4627.4 100 114.3 152 7.6 152 8.3 152 12.4 55.563621.5621.3635.3 125 141.3 152 9.8 152 9.7 152 16.0 66.625626.5627.5647.5 150 168.3 152 12.0 152 12.5 152 21.5 8 8.625639.0641.3670.3 200 219.1 152 17.7 152 18.8 152 31.9 10 10.750 8 57.0 8 59.8 8 100.8 250 273.0 203 25.9 203 27.1 203 45.7 12 12.750841.0888.28146.2 300 323.9 203 18.6 203 40.0 203 66.3 14 # 14.000 8 —8 +8 +350 355.6 203 203 203 16 # 16.000 8 —8 +8 +400 406.4 203 203 203 18 # 18.000 8 —8 +8 +450 457.0 203 203 203 20 # 20.000 8 —8 +8 +500 508.0 203 203 203 24 # 24.000 8 —8 +8 +600 610.0 203 203 203 14 – 24 350 – 600 TM For AGS fitting information, see publication 20.05 IMPORTANT NOTES: + Contact Victaulic for details. Flanged adapter nipples are supplied with standard rolled grooves. Standard cut grooves or machining for rubber lining are optionally available. Contact Victaulic for details. # For use on cut grooved systems only. For roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales office. 07.01_20 Grooved End Fittings 07.01IPS CARBON STEEL PIPE - GROOVED FITTINGS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_L NO. 20 TEENO. 10 ELBOW Swaged Nipple NO. 53 Grv. × Grv. NO. 54 Grv. × Thd. NO. 55 Thd. × Grv. (Steel) E to E NO. 53 E to E NO. 54 E to E NO. 55 Size No. 53, 54 and 55 Swaged Nipples Nominal Size Inches mm E to E Inches mm Approx. Weight Each Lbs. kg 2 × 16.50 2.0 50 25 165 0.9 1 1/4 6.50 2.0 32 165 0.9 1 1/2 6.50 2.0 40 165 0.9 2 1/2 × 1 7.00 3.0 65 25 178 1.4 1 1/4 7.00 3.0 32 178 1.4 1 1/2 7.00 3.0 40 178 1.4 2 7.00 3.0 50 178 1.4 3 × 1 8.00 4.5 80 25 203 2.0 1 1/4 8.00 4.5 32 203 2.0 1 1/2 8.00 4.4 40 203 2.0 28.00 4.5 50 203 2.0 2 1/2 8.00 4.5 65 203 2.0 3 1/2 × 38.00 6.8 90 80 203 3.1 4 × 19.00 7.5 100 25 229 3.4 1 1/4 9.00 7.5 32 229 3.4 1 1/2 9.00 7.5 40 229 3.4 2 9.00 7.5 50 229 3.4 4 × 2 1/2 9.00 7.5 100 65 229 3.4 Swaged Nipple NO. 53 Grv. × Grv. NO. 54 Grv. × Thd. NO. 55 Thd. × Grv. (Steel) E to E NO. 53 E to E NO. 54 E to E NO. 55 Size No. 53, 54 and 55 Swaged Nipples Nominal Size Inches mm E to E Inches mm Approx. Weight Each Lbs. kg 4 × 39.00 7.5 100 80 229 3.4 3 1/2 9.00 7.5 90 229 3.4 5 × 211.00 11.5 125 50 279 5.2 3 11.00 11.3 80 279 5.1 4 11.00 11.5 100 279 5.2 6 × 112.00 17.0 150 25 305 7.7 1 1/4 12.00 17.0 32 305 7.7 1 1/2 12.00 17.2 40 305 7.8 2 12.00 17.4 50 305 7.9 2 1/2 12.00 17.4 65 305 7.9 3 12.00 17.4 80 305 7.9 3 1/2 12.00 17.4 90 305 7.9 4 12.00 17.5 100 305 7.9 4 1/2 12.00 17.5 120 305 7.9 5 12.00 17.5 125 305 7.9 8 × 6 +20.0 200 150 9.1 + Contact Victaulic for details. 07.01_21 Grooved End Fittings 07.01IPS CARBON STEEL PIPE - GROOVED FITTINGS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_L NO. 20 TEENO. 10 ELBOW Female Threaded Adapter NO. 80 (Ductile Iron *) E to E NO. 80 Size No. 80 Female Threaded Adapter Nominal Size Inches mm Actual Outside Diameter Inches mm E to E Inches mm Approx. Weight Each Lbs. kg 3/4 1.050 2.00 1.0 20 26.9 51 0.5 11.3152.061.0 25 33.7 52 0.5 1 1/4 1.660 2.31 (sw) 1.5 32 42.4 59 0.7 1 1/2 1.900 2.31 (sw) 1.5 40 48.3 59 0.7 22.3752.501.4 50 60.3 64 0.6 2 1/2 2.875 2.75 1.5 65 73.0 70 0.7 3 3.500 2.75 2.9 80 88.9 70 1.3 44.5003.254.5 100 114.3 83 2.0 * Ductile iron except those marked (sw) which are segmentally welded steel. IMPORTANT NOTE: Available with British Standard Pipe threads, specify “BSP” clearly on order. Hose Nipple NO. 48 (Segmentally Welded Steel) E to E NO. 48 Size No. 48 Hose Nipple Nominal Size Inches mm Actual Outside Diameter Inches mm E to E Inches mm Approx. Weight Each Lbs. kg 3/4 1.050 3.12 0.3 20 26.9 79 0.1 11.3153.380.4 25 33.7 86 0.2 1 1/4 1.660 3.88 0.6 32 42.4 98 0.3 1 1/2 1.900 3.88 0.8 40 48.3 98 0.4 22.3754.501.1 50 60.3 114 0.5 2 1/2 2.875 5.38 2.0 65 73.0 137 0.9 33.5005.753.2 80 88.9 146 1.5 4 4.500 7.00 4.9 100 114.3 178 2.2 5 5.563 8.75 8.0 125 141.3 222 3.6 66.62510.1214.3 150 168.3 257 6.5 88.62511.8824.7 200 219.1 302 11.2 10 10.750 12.50 40.1 250 273.0 318 18.2 12 12.750 14.50 62.0 300 323.9 368 28.1 07.01_22 Grooved End Fittings 07.01IPS CARBON STEEL PIPE - GROOVED FITTINGS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_L NO. 20 TEENO. 10 ELBOW Concentric/Eccentric Reducer NO. 50 Concentric NO. 51 Eccentric (Ductile Iron ‡) E to E NO. 50 E to E NO. 51 Size No. 50 Concentric Reducer No. 51 Eccentric Reducer Nominal Size Inches mm E to E Inches mm Approx. Weight Each Lbs. kg E to E Inches mm Approx. Weight Each Lbs. kg 1 1/4 × 3/4 +1.9 ——32 20 0.9 1 +1.9 ——25 0.9 1 1/2 × 3/4 +1.4 —— 40 20 0.6 1 2.50 * (sw) 0.8 8.50 4.5 25 64 0.4 216 2.0 1 1/4 2.50 * (sw) 1.0 ——32 64 0.5 2 × 3/4 2.50 * (sw) 0.9 9.00 2.0 50 20 64 0.3 229 0.9 1 2.50 * (sw) 0.7 9.00 2.3 25 64 0.3 229 1.0 1 1/4 2.50 * (sw) 1.2 9.00 4.6 32 64 0.5 229 2.1 1 1/2 2.50 * (sw) 1.0 9.00 4.6 40 64 0.5 229 2.1 2 1/2 × 3/4 +1.3 +3.3 65 20 0.6 1.5 19.50 3.6 9.50 3.5 25 64 1.5 241 1.6 1 1/4 2.50 * (sw) 3.3 9.50 +32 64 1.5 241 1 1/2 2.50 * (sw) 3.6 9.50 3.7 40 64 1.6 241 1.7 2 2.50 (sw) 3.9 9.50 4.3 50 64 1.8 241 2.0 3 × 3/4 +1.5 +4.5 80 20 0.7 2.0 1 2.50 * (sw) 1.3 9.50 4.8 25 64 0.6 241 2.2 1 1/4 +3.0 +4.8 32 1.4 2.2 1 1/2 2.50 * (sw) 5.1 9.50 5.1 40 64 2.3 241 2.3 2 2.50 * (sw) 1.6 3.50 (sw) 6.0 50 64 0.7 89 2.7 2 1/2 2.50 * (sw) 1.8 3.50 (sw) 7.0 65 64 0.8 89 3.2 76.1 2.50 (sw) 2.1 ——64 1.0 Concentric/Eccentric Reducer NO. 50 Concentric NO. 51 Eccentric (Ductile Iron ‡) E to E NO. 50 E to E NO. 51 Size No. 50 Concentric Reducer No. 51 Eccentric Reducer Nominal Size Inches mm E to E Inches mm Approx. Weight Each Lbs. kg E to E Inches mm Approx. Weight Each Lbs. kg 3 1/2 × 3 2.50 (sw) 2.0 9.50 7.0 90 80 64 0.9 241 3.2 4 × 1 3.00 * (sw) 3.0 13.00 6.5 100 25 76 1.4 330 2.9 1 1/4 +4.6 ——32 2.1 1 1/2 10.00 6.9 10.00 8.1 40 254 3.1 254 3.7 2 3.00 * (sw) 2.4 4.00 (sw) 3.3 50 76 1.1 102 1.5 2 1/2 3.00 * (sw) 2.7 4.00 (sw) 3.4 65 76 1.2 102 1.5 3 3.00 * (sw) 3.2 4.00 (sw) 3.5 80 76 1.4 102 1.6 3 1/2 3.00 (sw) 2.9 10.00 8.0 90 76 1.3 254 3.6 5 × 2 11.00 9.0 11.00 5.2 125 50 279 4.1 279 2.4 2 1/2 11.00 11.0 11.00 10.8 65 279 5.0 279 4.9 3 4.00 (sw) 55 11.00 11.1 80 102 2.5 279 5.0 4 3.50 (sw) 4.3 5.00 (sw) 12.0 100 89 1.9 127 5.4 6 × 1 4.00 * (sw) 5.0 11.50 14.5 150 25 102 2.3 292 6.6 1 1/2 +5.5 ++40 2.5 2 4.00 * (sw) 6.6 11.50 14.5 50 102 3.0 292 6.6 2 1/2 4.00 * (sw) 6.4 11.50 14.2 65 102 2.9 292 6.4 3 4.00 * (sw) 6.4 5.50 (sw) 15.0 80 102 2.9 140 6.8 4 4.00 (sw) 6.5 5.50 (sw) 17.0 100 102 2.9 140 7.7 5 4.00 (sw) 6.4 5.50 (sw) 17.0 125 102 2.9 140 7.7 8 × 2 1/2 16.00 * (sw) 7.9 12.00 26.1 200 65 406 3.6 305 11.8 3 5.00 (sw) 9.3 12.00 22.0 80 127 4.2 305 10.0 07.01_23 Grooved End Fittings 07.01IPS CARBON STEEL PIPE - GROOVED FITTINGS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_L NO. 20 TEENO. 10 ELBOW Concentric/Eccentric Reducer NO. 50 Concentric NO. 51 Eccentric (Ductile Iron ‡) E to E NO. 50 E to E NO. 51 Size No. 50 Concentric Reducer No. 51 Eccentric Reducer Nominal Size Inches mm E to E Inches mm Approx. Weight Each Lbs. kg E to E Inches mm Approx. Weight Each Lbs. kg 8 × 4 5.00 (sw) 10.4 12.00 23.0 200 100 127 4.8 305 10.4 5 5.00 (sw) 11.6 12.00 23.0 125 127 5.2 305 10.4 6 5.00 (sw) 11.9 6.00 (sw) 24.0 150 127 5.4 152 10.9 10 × 4 6.00 (sw) 19.7 13.00 32.0 250 100 152 8.9 330 14.5 5 +34.3 +34.6 125 15.6 15.7 6 6.00 (sw) 20.0 13.00 36.9 150 152 9.1 330 16.7 8 6.00 (sw) 22.0 7.00 (sw) 21.6 200 152 10.0 178 9.8 12 × 4 +44.0 14.00 48.0 300 100 20.0 356 21.8 6 7.00 (sw) 24.6 14.00 50.0 150 178 11.2 356 22.7 8 7.00 (sw) 52.0 14.00 53.5 200 178 23.6 356 24.3 10 7.00 (sw) 39.0 14.00 57.0 250 178 17.7 356 25.9 # 14 × 6 13.00 65.0 13.00 60.0 350 150 330 29.5 330 27.2 8 13.00 65.0 13.00 60.0 200 330 29.5 330 27.2 10 13.00 66.0 13.00 65.0 250 330 29.9 330 29.5 12 13.00 68.0 13.00 66.0 300 330 30.8 330 29.9 # 16 × 814.00 73.0 14.00 73.0 400 200 356 33.1 355 33.1 10 § 14.00 73.0 14.00 73.0 250 356 33.1 355 33.1 12 14.00 73.0 14.00 73.0 300 356 33.1 355 33.1 14 14.00 73.0 14.00 73.0 350 356 33.1 355 33.1 # 18 × 10 15.00 91.0 15.00 91.0 450 250 381 41.3 381 41.3 Concentric/Eccentric Reducer NO. 50 Concentric NO. 51 Eccentric (Ductile Iron ‡) E to E NO. 50 E to E NO. 51 Size No. 50 Concentric Reducer No. 51 Eccentric Reducer Nominal Size Inches mm E to E Inches mm Approx. Weight Each Lbs. kg E to E Inches mm Approx. Weight Each Lbs. kg # 18 x 12 15.00 91.0 15.00 91.0 450 300 381 41.3 381 41.3 14 15.00 91.0 15.00 91.0 350 381 41.3 381 41.3 16 15.00 91.0 15.00 91.0 400 381 41.3 381 41.3 # 20 × 10 20.00 110.0 20.00 177.0 500 250 508 49.9 508 80.3 12 20.00 120.0 20.00 120.0 300 508 54.4 508 54.4 14 20.00 149.0 20.00 149.0 350 508 67.9 508 67.9 16 20.00 120.0 20.00 120.0 400 508 54.4 508 54.4 18 20.00 136.0 20.00 136.0 450 508 61.7 508 61.7 # 24 × 10 20.00 142.0 20.00 142.0 600 250 508 64.4 508 64.4 12 20.00 150.0 20.00 150.0 300 508 68.0 508 68.0 14 20.00 162.0 20.00 162.0 350 508 73.5 508 73.5 16 20.00 162.0 20.00 162.0 400 508 73.5 508 73.5 18 20.00 162.0 20.00 162.0 450 508 73.5 508 73.5 20 20.00 151.0 20.00 190.0 500 508 68.5 508 86.2 14 – 24 350 – 600 TM For AGS fitting information, see publication 20.05 + Contact Victaulic for details. * Available with male threaded small end No. 52. ‡ Ductile Iron except those marked (sw) which are segmentally welded steel. IMPORTANT NOTE: Steel eccentric reducers available through 30"/750 mm, contact Victaulic for dimensions. # For use on cut grooved systems only. For roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales office. § cast fitting available for J.I.S. size. Contact Victaulic for details. 07.01_24 Grooved End Fittings 07.01IPS CARBON STEEL PIPE - GROOVED FITTINGS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_L NO. 20 TEENO. 10 ELBOW Small Threaded Reducer NO. 52 (Ductile Iron *) E to E NO. 52 E to E NO. 52F Size No. 52 Small Threaded Reducer No. 52F Concentric Reducer with BSPT Female Threaded End Nominal Size Inches mm E to E Inches mm Approx. Weight Each Lbs. kg E to E Inches mm Approx. Weight Each Lbs. kg 1 1/2 × 12.50 0.8 ——40 25 64 0.4 1 1/4 2.50 0.9 ——32 64 0.4 2 × 3/4 2.50 0.9 ——50 20 64 0.4 12.50 0.7 ——25 64 0.3 1 1/4 2.50 1.2 ——32 64 0.5 1 1/2 2.50 1.0 ——40 64 0.5 2 1/2 × 1 + (sw)1.0 ——65 25 0.5 1 1/4 2.50 (sw) 1.2 ——32 64 0.5 1 1/2 2.50 (sw) 1.3 ——40 64 0.6 2 3.00 1.4 ——50 76 0.6 76.1 × 48.3 63.5 0.8 63.5 0.77 60 — — 63.5 0.85 3 × 3/4 + (sw)1.5 ——80 20 0.7 12.50 1.3 ——25 64 0.6 1 1/2 2.50 (sw) 1.5 ——40 64 0.7 2 2.50 1.5 ——50 64 0.7 2 1/2 2.50 2.4 ——65 64 1.1 88.9 × 42.4 63.5 0.9 63.5 0.82 48.3 63.5 0.9 63.5 0.85 60 — — 63.5 0.89 4 × 13.00 2.3 ——100 25 76 1.0 1 1/2 + (sw)2.5 ——40 1.1 23.00 2.6 ——50 76 1.2 Small Threaded Reducer NO. 52 (Ductile Iron *) E to E NO. 52 E to E NO. 52F Size No. 52 Small Threaded Reducer No. 52F Concentric Reducer with BSPT Female Threaded End Nominal Size Inches mm E to E Inches mm Approx. Weight Each Lbs. kg E to E Inches mm Approx. Weight Each Lbs. kg 4 × 2 1/2 3.00 2.6 ——100 65 76 1.2 3 3.00 2.5 ——80 76 1.1 108 × 42.4 76.2 1.3 76.2 1.32 48.3 76.2 1.3 76.2 1.35 60 — — 76.2 1.39 114.3 × 42.4 76.2 1.3 76.2 1.30 48.3 76.2 1.3 76.2 1.34 60 — — 76.2 1.40 5 × 4 +4.5 ——125 100 2.0 133 × 60 — — 114.3 2.17 139 × 60 — — 114.3 2.26 6 × 14.00 5.5 ——150 25 102 2.5 2 4.00 5.7 ——50 102 2.6 2 1/2 4.00 5.8 ——65 102 2.6 3 4.00 5.8 ——80 102 2.6 4 + (sw)6.5 ——100 2.9 5 + (sw)2.0 ——125 0.9 159 x 42.4 114.3 2.2 114.3 2.45 48.3 114.3 2.2 114.3 2.51 60 — — 114.3 2.60 165.1 x 42.4 101.6 2.4 101.6 2.90 48.3 101.6 2.6 101.6 2.95 60 — — 101.6 3.00 8 × 216.00 1.5 ——200 50 406 0.7 2 1/2 16.00 1.7 ——65 406 0.8 + Contact Victaulic for details. * Ductile iron except those marked (sw) which are segmentally welded steel. IMPORTANT NOTE: Available with British Standard Pipe Threads, specify "BSP" clearly on order 07.01_25 Grooved End Fittings 07.01IPS CARBON STEEL PIPE - GROOVED FITTINGS www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_L NO. 20 TEENO. 10 ELBOW WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. NOTE 07.01 Grooved End Fittings 07.01IPS CARBON STEEL PIPE - GROOVED FITTINGS WCAS-6M8PF7 UPDATED 9/2006 07.01 1449 REV L VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. US & WORLD HEADQUARTERS P.O. Box 31 Easton, PA 18044-0031 USA 4901 Kesslersville Road Easton, PA 18040 USA 1-800-PICK-VIC (1-800-742-5842) 1-610-559-3300 1-610-250-8817 (fax) pickvic@victaulic.com CANADA 905-884-7444 905-884-9774 (fax) viccanada@victaulic.com EUROPE 32-9-381-15-00 32-9-380-44-38 (fax) viceuro@victaulic.be UNITED KINGDOM 44 (0) 1438741100 44 (0) 1438313883 (fax) viceuro@victaulic.be CENTRAL AND SOUTH AMERICA 1-610-559-3300 1-610-559-3608 (fax) vical@victaulic.com ASIA PACIFIC 86-21-54253300 86-21-54253671 (fax) vicap@victaulic.com MIDDLE EAST 971-4-883-88-70 971-4-883-88-60 (fax) www.victaulic.com NO. 20 TEENO. 10 ELBOW