Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LOAD SHORT FORM - 16-00688 - 895 S 2380 W - SFR
Load Short Form Job: SF2084 Date: 1015116 Entire House By: Vince Byram ° Katchner •vpr pp: Yr an nnninp. 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 ?troject Intormation For: Cody Puzey, Kartchner Homes 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-.529-2116 Outside db (°F) Ins idedb(°F) Design TD (°F) Daily range Inside humidity (%) Moisture difference (gr/Ib) Htg -6 68 74 - 50 57 CIg 89 75 14 H 50 -31 Infiltration Method Construction quality Fireplaces Simplified Average 0 HEATING EQUIPMENT Room7 COOLING EQUIPMENT Make Goodman Mfg. 1398 160 Make Goodman Mfg. Room9 Trade GOODMAN 3365 1681 Trade GOODMAN, JANITROL, AMANA DIST]... Model GMH950703BX Rooml1 162 Cond GSX130301D* 168 AHRI ref 2002183 10 Room12 Coil CA*F3636*6D* 2635 1743 61 107 AHRI ref 5347446 60 Efficiency 95 AFUE 14 Efficiency 11.0 EER, 13 SEER Heating input 69000 Btuh Sensible cooling 19600 Btuh Heating output 52400 Btuh Latent cooling 8400 Btuh Temperature rise 66 'F Total cooling 28000 Btuh Actual air flow 859 cfm Actual air flow 859 cfm Air flow factor 0.023 cfm/Btuh Air flow factor 0.062 cfm/Btuh Static pressure 0.70 in H2O Static pressure 0.70 in H2O Space thermostat CO. 44G Load sensible heat ratio 1.00 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) Room7 320 6869 1398 160 86 Room9 288 3365 1681 78 103 Rooml1 162 856 168 20 10 Room12 165 2635 1743 61 107 Room14 60 587 75 14 5 Room15 180 3192 1440 74 89 Room16 210 2448 1394 57 86 Room18 363 3911 1145 91 70 Room5 432 7624 2420 178 149 Room6 288 4718 2376 110 146 D..--4 4r1L: CO. 44G AC -i Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsaft' Right -Suite® U niversal 2017 17.0.03 RSU20477 2016 -Oct -0517:78:46 e1 �r+ Page 1 /p�+�...R\Documents\wrightsoftware\Kartchner\sf15b3.rup Calc=MJB House faces: W Entire House d 2573 36841 13955 859 859 Other equip loads 3617 684 Equip. @ 0.94 RSM 13761 Latent cooling 0 Tn1 Al Q 1gC90 i Al1A C9 AOOLA i ocn nvn Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 20160ct-05 17:18:46 WMiLjht50f't' Right -Suite® Universal 2017 17A03 RSU20477 Paget ✓T -t+91 ...R\Documents\wrightsoflware\Kartchner\sfl5b3.rup Calc=MJ8 House faces: W Buildin Anal sis Job: S g Y Date: 101151155116 Entire House By: Vince Byram ' Katchner MIo11n0 m IMlllq 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Project Information For: Cody Puzey, Kartchner Homes 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Location: Idaho Falls, ID, U8 Elevation: 474' Latitude:4, Outdoor: Dry bulb (°F) Daily range (°F) Wet bu lb CF) Wind speed (mph) Heating -6 15.0 Cooling 89 34 (H ) 60 7.5 Indoor: Heating Indoor temperature (OF) 68 Design TO (°F) 74 Relative humidity (%) 50 Moisture difference (gr/Ib) 57.0 Infiltration: 16.4 Method Simplified Construction quality Average Fireplaces 0 Heating Component Btuh/ft= Btuh % of load Walls 4.8 12217 30.2 Glazing 25.2 6619 16.4 Doors 12.6 264 0.7 Ceilings 1.5 2269 5.6 Floors 3.2 4881 12.1 Infiltration 3.8 10591 26.2 Ducts 0 0 Piping 0 0 Humidification 0 0 Ventilation 3617 8.9 Adjustments 0 Total 40457 100.0 Cooling Component Btuh/ft' Btuh % of load Walls 0.5 1205 8.2 Glazing 32.1 8450 57.7 Doors 3.1 66 0.5 Ceilings 0.8 1288 8.8 Floors 0.0 30 0.2 Infiltration 0.4 1026 7.0 Ducts 0 0 Ventilation 684 4:7 Internal gains 1890 12.9 Blower 0 0 Adjustments 0 Total 14640 100.0 Latent Cooling Load = 0 Btuh Overall LI -value =0.060 Btuh/ft=--°F Data entries checked. �'-� '�'Wrightsoft` Right -Suite® Universal 2017 17.0.03 RSU20477 .ec*...R\Documents\wrightsoflware\Kartchner\sf15b3.rup Calc=MJO Housefaces: W 50 -31.5 2016-Oc1-0517:18:46 Page 1 Com onent Constructions Job: S p Date: 1o15116sws Entire House By: Vince Byram ° Katchner tlp11I•, ir. nn Itlnelnp 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Project• For: Cody Puzey, Kartchner Homes 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Location: Idaho Falls, ID, US Elevation: 4741 ft Latitude: 44'N Outdoor: Heating Dry bulb (T) -6 Dailyrange (°F) - Wet bulb (T) - Wind speed (mph) 15.0 Cooling 89 34 (H ) 60 7.5 Indoor: Indoor temperature (°F) Design TD (TF) Relative humidity (%) Moisture difference (gr/Ib) Infiltration: Method Construction quality Fireplaces Construction descriptions or Area LI -value Insul R 0 w 132 fY BIWtIR�°F n'-'FOh Walls 0 e 21 0.170 6.0 12F-Osw: Frm wall, vnl ext, 3/8" wood shth, r-21 cav ins, 1/2" gypsum n 668 0.065 21.0 board int fnsh, 2"k6" wood frm, 16" o.c. stud a 592 0.065 21.0 2830 S 692 0.065 21.0 0.47 w 588 0.065 21.0 all 2540 0.065 21.0 Partitions (none) Windows 61C: 61 C Doors metal: Door, mtl pur core type Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 cell ins, 1/2" gypsum board int fnsh Floors 20P -30c: Fir floor, frm fir, 12" thkns, carpet fir fnsh, r-30 ext ins, r-30 cav ins, gar ovr 228-15cpm: Bg floor, heavy dry or light damp soil, on grade depth, r-15 edge ins, carpet fir fnsh n 24 0.340 0 e 107 0.340 0 w 132 0.340 0 all 263 0.340 0 e 21 0.170 6.0 1533 0.020 50.0 Heating Cooling 68 75 74 14 50 50 57.0 -31.5 Simplified Btuh Average 3213 0 317 25.2 604 10.5 251 25.2 2702 32.8 3526 25.2 3313 32.8 4323 25.2 6619 30.8 8100 12.6 264 3.14 66 1.48 2269 0.84 1288 433 0.035 30.0 2.59 Htg HTM Loss Clg HTM Gain BnAttt' Btuh Bluhtt Btuh 4.81 3213 0.47 317 4.81 2846 0.47 281 4.81 33291 0.47. 328 4.81 2830 0.47 279 4.81 12217 0.47 1205 25.2 604 10.5 251 25.2 2702 32.8 3526 25.2 3313 32.8 4323 25.2 6619 30.8 8100 12.6 264 3.14 66 1.48 2269 0.84 1288 433 0.035 30.0 2.59 1121 0.07 30 156 0.314 15.0 23.2 3625 0 0 6 0.314 15.0 23.2 134 0 0 all 162 0.314 15.0 23.2 3759 0 0 2016 -Oct -0517:16:46 wrightsaft° Right -Suite® Universal 2017 17.0.03 RSU20477 Pagel fl s... R\Documents\wrightsofMare\KaOchner\sf15b3.rup Calc =MJ8 House faces: W Project Summary Entire House HeiKatchner 607 West 7700 South, Logan, Utah 84321 Phone: 435-758-7080 Project Information For: Cody Puzey, Kartchner Homes 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Notes: Job: SF2084 Date: 1015116 By: Vince Byram Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wil Itt50Tt" 2016 -Oct -0517:18:46 Rig ht -Suite® U niversal 2017 17.0.03 RSU20477 Page 1 ...R\Dccuments\wrighlsoftware\Kartchnerlsfl5b3.rup Calc=MJ8 Housefaces: W Design Information Weather: Idaho Falls, ID, US Winter Design Conditions Summer Design Conditions Outside db -6 OF Outside db 89 OF Inside db 68 OF Inside db 75 OF Design TD 74. OF Design TD 14 OF Daily range H Relative humidity 50 % Moisture difference -31 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 36841 Btuh Structure 13955 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (53 cfm) 3617 Btuh Central vent (53 cfm) 684 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 40457 Btuh Use manufacturer's data n Rate/swing multiplier 0.94 Infiltration Equipment sensible load 13761 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure -827 Btuh Ducts 0 Btuh Heating Cooling Central vent (53 cfm) -951 Btuh Area (ftp 2573 2573 Equipment latent load 0 Btuh Volume (ft3) 22664 22664 Air changes/hour 0.41 0.21 Equipment total load 13761 Btuh Equiv. AVF (cfm) 155 79 Req. total capacity at 0.70 SHR 1.6 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg. Make Goodman Mfg. Trade GOODMAN Trade GOODMAN, JANITROL, AMANA DIST]... Model GMH950703BX Cond GSX130301D* AHRI ref 2002183 Coil CA*F3636*6D* AHRI ref 5347446 Efficiency 95 AFUE Efficiency 11.0 EER, 13 SEER Heating input 69000 Btuh Sensible cooling 19600 Btuh Heating output 52400 Btuh Latent cooling 8400 Btuh Temperature rise 66 OF Total cooling 28000 Btuh Actual air flow 859 cfm Actual air flow 859 cfm Air flow factor 0.023 cfm/Btuh Air flow factor 0.062 cfm/Btuh Static pressure 0.70 in H2O Static pressure 0.70 in H2O Space thermostat Load sensible heat ratio 1.00 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wil Itt50Tt" 2016 -Oct -0517:18:46 Rig ht -Suite® U niversal 2017 17.0.03 RSU20477 Page 1 ...R\Dccuments\wrighlsoftware\Kartchnerlsfl5b3.rup Calc=MJ8 Housefaces: W AED Assessment Entire House ° Katchner •,n1aP_ tl. onlrinnlnp 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 • For: Cody Puzey, Kartchner Homes 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Job: SF20B4 Date: 1015116 By: Vince Byram Test for Adequate Exposure Diversity Hourly Glazing Load i rvounv i a.e,ape i imumi Maximum hourly glazing load exceeds average by 35.1%. House does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 350 Btuh (PFG - 1.3*AFG) _ e 2016-00-05 17:18:46 //��ffi+.-� uvriightsoftt Right -Suite@ U niversal 2017 17.0.03 RSU20477 Pagel . lM ...R\Documents\wrightsoftware\Kartchner\sfl5b3.rup Calc=M.18 Housefaces: W Design Conditions Location: Indoor: Heating Cooling Idaho Falls, ID, US Indoor temperature (°F) 68 75 Elevation: 4741 ft Design TD (°F) 74 14 Latitude: 44°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 57.0 -31.5 Dry bulb IT) -6 89 Infiltration: Dailyrange (°F) - 34 (H ) Wetbulb(°F) - 60 Wind speed (mph) 15.0 7.5 Test for Adequate Exposure Diversity Hourly Glazing Load i rvounv i a.e,ape i imumi Maximum hourly glazing load exceeds average by 35.1%. House does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 350 Btuh (PFG - 1.3*AFG) _ e 2016-00-05 17:18:46 //��ffi+.-� uvriightsoftt Right -Suite@ U niversal 2017 17.0.03 RSU20477 Pagel . lM ...R\Documents\wrightsoftware\Kartchner\sfl5b3.rup Calc=M.18 Housefaces: W Right -M Worksheet o Entire House Katchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Job: SF20134 Date: 1015116 By: Vince Byram 1 Room name Entire House Room7 2 Exposed wall 314.0 ft 56.0 it 3 Room height 8.8 R it 10.0 it heat/cool 4 Room dimensions 16.0 x 20.0 it 5 Room area 2573.0 ft2 320.0 fP T Y Construction U -value Or HTM Area ft' I Load I Area it- Load number (13tuh/ft°-°F (Btuh/ft2) or perimeter (ft) (Bluh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Coal Gross N/P/S Heal Cool 611! 12FOsw 0.065 n 1.4.81 0.47 692 - 3213 317 200 ' 200 :962 95 G 61C 0.340 n 25.16 10.46 24 .668 0 604 251 0 0 0 0 12F-Osw 0.065 a 4.81 0.47 720 592 2846 281 160 109 524 52 61C 0.340 a 25.16 32.83 107 0 2702 3526 30 0 755 985 11 metal 0.170 a 12.58 3.14 21 21 264 66 21 21 264 66 W 12F-Osw 0.065 s 4.81 0.47 692. 692 3329 328 200 200 962 95' l�! 12F-0sw 0.065 w 4.81 0.47 720 588 2830 279 0 0 0 0 L -G 61C 0.340 w 25.16 32.83 132 0 3313 4323 0 0 0 0 C 1613-50ad 0.020 - 1.48 0.84 I' 1533 1533 2269 128B 0 0 0 0 F 20P -30c 0.035 - 2.59 0.07 433 433 1121 30 0 0 0 0 F 22B-15cpm - .0.314 - 23.24 0.00 1040 156 3625 0 `. 320 56 1301 0 F 2213-15com 0.314 - 23.24 0.00 60 6 134 D 0 0 0 0 6 c)AED excursion 350 -J -98 Envelope loss/gain 26250 11039 1 4766 1194 12. a) Infiltration 10591 1 1026 2100 204 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 3 690 0 0 Appliancesiother 1200 0 Subtotal (lines 6 to 13) 38847 13955 fiB89 1398 Less external load 0 0 0U Less transfer 0 0 0 Redistribution 0 0 0 14 Subtotal 36841 13955 6869 15 Duct loads 0% 0% 0 0 -0% 0% 0 To.1 - calmom 381 38591 688901 3861 I (c m I I I 859 II I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. '46:BS -Fk wrightsaft° 2016 -Oct -0517:18:46 Right -Suite® Universal 2017 17.0.03 RSU20477 Page 1 ...R\Documents\wrightsoftware\Kartchnertsfl5b3.rup Calc=MJB Housefaces: W Right -M Worksheet Entire House Katchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Job: SF2084 Date: 1015116 By: Vince Byram I Room name Room9 Roomll 2 Exposed wall 34.0 it 9.0 it 3 Room height 8.0 it heat/cool 8.0 ft heat/cool 4 Roam dimensions 16.0 x 18.0 ft 9.0 x 18.0 It '5 Room area 288.0 fl" 162.0 fW Ty Constmction U -value Or I HTM I Area (it') Load Area '(f W) Load number (Blah/fR°FJ� (Btuh/f P) or perimeter (ft) (Blah) or perimeter (ft) I (Blah) Heat Cool Grass N/P/S Heat Cool Gross NIP/S Heal Cool 6 0.085 n 4.81 10.47 0 0 0 0 0 0 0 0 L1Osw G 61CC 0.340 n 25.18 10.48 0 0 0 0> 0 0 0 0 12F-0sw 0.065 a 4.81 0.47 0 0 0 0 0 0 0 0 �-G 61C 0.340 a 25.16 32.83 0 0 0 0 0 0 0 0 11 I -D metal 0.170 a 12.58 3.14 0 0 0 0 0 0 0 0 W12F Osw 0.065 a 4.61 0.47 144 i' 144 693 68 - 0 0 '0 0 1'� 12F-Osw 0.065 w 4.81 0.47 128 98 471 47 72 72 346 34 `G BIC 0.340 w 25.16 32.83 30 0 755 985 0 0 0 0 C. 16B 50ad 0.020 - 1:48 '0.84 288 " 288 ..426 242 162 - 162 240 136 F 20P -30c 0.035 - 2.59 0.07 0 0 0 0 0 0 0 0 F 22B 15cpm 0.314 - 23.24 0.00 0 0 ' 0 0 0 0- 0 - 0 F 229-15cpm 0.314 - 23.24 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 240 -29 Envelope loss/gain 2345 1582 586 141 12 a) Infiltration 1020 99 270 b) Room ventilation 0 0 013 Internal gains: OccupantsQ 230 0 0 0 126 Appliances/other 0 Subtotal (lines 6 to 13) 3365 1681 856 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3365 1681 856 168 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 load roomd(cm) 33781 11031 8201 168 Aotre9uireI 1 I I I 01 Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed. -PV- wrightsQft- 2016-Oc1-0517:18:48 Right -Suite® U niversal 2017 17.0.03 RSU20477 ... R\Documents\wrightsoftware\KarlchneAsf15b3.rup Calc =MJ8 House faces: W Paget Right -M Worksheet Entire House 9 Katchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Job: SF20B4 Date: 10/6/16 By: Vince Byram 1 Roam name Room12 Room14 2 Exposed wall 26.0 it 5.0 R 3 Room height 8.0 it heat/coal 8.0 it heat/coal 4 Roam dimensions 15.0 x 11.0 It 12.0 x 5.0 ft 5 Room area 165.0 fP 60.0 it, T Y Construction U -value Or I HTM I Area ft° I Load I Area ft2 I Load number (Htuh/ft'-°F (Bt uh/ftp or perimeter (f0 (Btuh) or perimeter (ft) (Bluh) Heat Cool Gross N/P/S Heal Cool Gross N/P/S Heat Coal 6 12F Osw 0.065 n 4.81 0.47 88 88 423 42 0 0 ' 0 0 - Y 61C 0.340 n 25.16 - 10.46 0 0 0 0 0 0 0 0 VLG 12F-0sw 0.065 a 4.81 0.47 0 0 0 0 0 0 0 0 61C 0.340 a 25.16 32.83 0 0 0 0 0 0 0 0 11 D metal 0.170 a 12.58 3.14 0 0 0 0 0 0 0 0 W72F-Osw 0.065 s -, 4,81 0.47 0 0 0 0 40 40 192 19 W 12F-0sw 0.065 w 4.61 0.47 120 90 433 43 0 0 0 0 LG 61C 0.340 w 25.16 32.83 30 0 755 985 0 0 0 0 C 16B-50ad 0.020 1.48 0.84 165 165 .244 .139 60 60 89 - 50 F 20P -30c 0.035 - 2.59 0.07 0 0 0 0 60 60 155 4 F 22B 15cpm 0.314 23.24 0.00 0 0 ''0 0 '- 0 -- 0 0 0 F 22B-15cpm 0.314 - 23.24 0.00 0 0 0 0 0 0 0 0 61 c)AED excursion230 -13 Envelope loss/gain 1855 1438 11 437 61 12 a) Infiltration 780 76 150 15 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 1 230 0 0 Appliances/other 0 0 Subtotal (lines B to 13) 2635 1743 587 75 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2635 1743 587 75 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 lquv 26611 35 743 11071 5841 751 1 Air red (cfm) 1 1 1 1 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Aft -11i wriligilhirtsoft' 'c-`.H,WvighYsaft^ 46 Right-Sulte® U universal 2017 17.0.03 RSU20477 2016 -Oct ... R\Documents\wrightsofNare\KaachneMf15b3.rup Cale =M.18 House faces: W g Right -M Worksheet Entire House Katchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Job: SF20B4 Date: 1015116 By: Vince Byram 1 Room name Room15 Room16 2 Exposed wall 27.0 If 15.0 ft 3. Room height 8.0 It heat/cool 8.0 It heat(cool 4 Room dimensions 12.0 x 15.0 ft 1.0 x 210.0 ft 5 Room area 180.0'W 210.0 fl - Ty Construction U -value OrI HTM Area (W)I Load I Area (f P) Load number (Btuh/ft"I': (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heal Cool Gross N/P/S Heat Cool Gross N/P/S Heal Cool 6 V"12F-Osw 0.065 n 4.81 i 047 0 0 0 0 8 tTi� 8 38 4 61C 0.340 n 25.16 10.46 0 0 0 q 0 0 0 0 VLG 12F-Osw 0.065 a 4.81 0.47 96 66 317 31 104 74 356 35 61C 0.340 a 25.16 32.83 30 0 755 985 30 0 755 985 17 D metal 0.170 a 12.58 3.14 0 0 0 0 0 0 0 0 W 12F-Osw 0.065 a - 4.81 0.47 120 ` 120 577 '57 8 8 [ 38 4 YN 12F-Osw 0.065 w 4.81 0.47 0 0 0 0 0 0 0 0 L --G 61C 0.340 w 25.16 32.83 0 0 0 0 0 0 0 0 C ,� 16B-50ad 0.020 - 1.48 0.84 180 180. 266 151 210 210 '311 178' F 20P -30c 0.035 - 2.59 0.07 180 180 466 13 193 193 500. 14 F 22B-15cmn 0.314 - 23.24 0.00 0- 0 0 0 0 0 0 0 F 2213-15cpm 0.314 - 23.24 0.00 0.. 0 0 0 0 0 0 0 6 c)AED excursion -706 -98 Envelope loss/gain 2382 1137 1998 1120 12 a) Infiltration 810 79 450 44 b) Room ventila0on 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) 3192 1440 2448 1394 Less external load 0 0 O 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3192 1440 2448 1394 15 Duct loads -0% 0% 0 0 -0% 0% 0,11 0 roomd 31941 14891 24581 13861 AirtrequireToI (c m) I Iload I .J•. Calculations aooroved by ACCA to meet all requirements of Manual J 8th Ed. -pk wrlght Qft- 2016 -Oct -0517:18:46 Rig ht-Suile® U niversal 2017 17.0.03 RSU20477 Page 4 ...R\Documents\wrightsoflware\Kartchner\sf15b3.rup Cele=MJ8 House faces: W Right -M Worksheet Entire House "r "^ Katchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Job: SF20B4 Date: 10/5116 By: Vince Byram 1 Room name Room18 Rcom5 2 Exposed wall 35.0 it 66.0 ft 3 Room height 8.0 It heat/cool 10.0 H heat/cool 4 Room dimensions 1.0 x 363.0 It 24.0 x 18.0 ft 5 Room area 363.0 W 432.0 ft' Ty Construction U-valua Or I HTM I Area (ft') Load I Area (f P) I Load number (Bt uh/ft;'F at uh/fP) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cooi Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W/ 12FOsw 0.065 n4.81 047 160 136 654 651 0 0 l0 0 �G 61C 0.340 n 25.16 10.46 24 0 604 251. 0 0 0 0 12F-Osw 0.065 a 4.81 .0.47 120 103 494 49 240 240 1154 114 61C 0.340 'e 25.16 32.83 17 0 438 571 0 0 0 0 11 metal 0.170 a 12.58 3.14 0 0 0 0 0 0 0 0 W12F-0sw ' 0.065 s 4.81 047 0 0 '0 0 180 180 866 85 4�J 12F-Osw, 0.065 w 4.81 0.47 0 0 0 0 240 218 1050 104 t -G 61C 0.340 w 25.16 32.83 0 0 0 0 22 0 545 711 C 16B-50ad 0.020 - 7.48 0.84 363 -. 363 537 305 0 0 'D 0 F 20P -30c 0.035 - 2.59 0.07 0 0 0 0 0 0 0 0 F 2213-15cpm '. 0.314 `- 23.24 000 0 0 0 0 432 fib 1534 0 F 2213-15com ..0.314 - 23.24 0.00 60 6 134 0 0 0 0 0 61 c)AED excursion -197 -34 Envelope loss/gain 2861 1044 5149 980 12 a) Infiltration 1050 102 2475 240 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 7200 Subtotal (lines 6 to 13) 3911 1145 7624 2420 Less external load 0 0 0 0 Less Vansfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3911 1145 7624 2420 15 Duct loads -0% 0% 01 0 -0% 0% 0 0 mom load Air 39911 11701 76781 21491 required (cm) Ial I I Calculations aooroved by ACCA to meet all requirements of Manual J 8th Ed. -:V- Ad- Wrightsoft` 2016 -Oct -0517:18:46 Right -Suite® Universal 2017 17.0.03 RSU20477 Page ...R\Documents\wrightsofhware\Karichner\sfl5b3.rup Calc=MJB Housefaces: W Right -J® Worksheet Entire House Katchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 Job: SF20B4 Date: 1015116 By: VinceByram 1 Room name Roams Roomi 2 Exposed wall 34.0 it 7.0 it 3 Room height 10.0 it heat/cool 8.0 it heat/cool 4 Room dimensions 16.0 x 18.0 it 15.0 x 7.0 7t 5 Room area 288.0 ft2 105.0 ft' Ty Constmction U -value Or I HTM I Area (fP) Load I Area (W) I Load number (Bluh/ftx°F (Bt uh/fl) or perimeter (it)(Btuh) or perimeter (ft) (Bluh) Heat Cool Gross I N/P/S Heat Cool Gross N/P/S Heal Cool 1 6 lM I 12F-Osw .065 n 5.81 047 180 780 886 85 56 56 269 27. 61C 0 0.340 2 25. 10.46 0 0 0 0 :. 0 0 0 0 -G �j 12F -Oso, 0.065 0.085 a 4.8181 0.47 0 0 0 0 0 0 0 0 _G 61C 0.340 ' e 25.16 32.83 0 0 0 0 0 0 0 0 71 metal 0.170 a 12.56 3.14 0 0 0 0 0 0 0 0 W 12F Osw 0.065 a 4.81 0.47 0 0 0 0 0: 0 0 '0 'L 12F-Osw 0.065 w 4.81 0.47 160 l W 529 52 0 0 0 0 -G 61C 0.340 w 25.16 32.83 50 0 1258 _ 1642 0 0 0 0 c 16B-50ad 0.020 ` - 1.48 0.84 0 0 0 0 105 105 155 88 F 2OP-30c 0.035 - 2.59 0.07 0 0 0 0 0 0 0 0 F 22B-15cpm 0.314 - 23.24 0.00 288 34 790 - 0 0 0 0 0 F 22B-15cpm 0.314 23.24 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 474 -20 Env elope loss/gain 3443 2253 1 425 95 12 a) Infiltration 1275 124 210 20 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) i 4718 2376 635 115 Less external load 0 0 0 Less transfer 0 0 0 Redistribution 0 0 :]o 0 14 Subtotal 4716 2376 175 15 Duct loads -0% 0% 0 0 -0% 0% 0 roomload 41 2o 6151 171 I I I 101 1461A� I I Calculations aooroved by ACCA to meet all reauirements of Manual J 8th Ed. WrigM1tsOTY Right -Suite® Universal 2017 17.0.03 RSU20477 201&Oc1-0517a8:e6 ...R\Documents\wdghtsoftware\Kadchner\sfi 5b3.mp Calc =MJ8 House faces: W Page Loads for Multiple Orientations Job: SF20B4 Date: 10/5116 Entire House By: Vince Byram Naar np. rr an BlMrnp Katchner 601 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 For: Cody Puzey, Kartchner Homes 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Location: North Indoor: Heating Cooling Idaho Falls, ID, US Southwest18509 Indoor temperature (°F) 68 75 Elevation: 4741 ft 12397 Design TD (°F) 74 14 Latitude: 44°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 57.0 -31.5 Dry bulb (°F) -6 89 Infiltration: 10034 12397 Dailyrange (°F) - 34 (H ) 10453 13282 Wetbulb(`F) - 60 859 859 859 Wind speed (mph) 15.0 7.5 859 859 House North Northeast East Southeast South Southwest18509 Northwest, Sensible Load (Btuh) 10034 12397 13609 12389 10453 13282 12113 Latent Load (Btuh) 0 0 0 0 0 0 0 Total Load (Btuh) 10034 12397 13609 12389 10453 13282 12113 Heating AVF (cfm) 859 859 859 859 859 859 859 Cooling AVF (cfm) 859 859 859 859 859 859 859 Elailding Orientation Cooling Load Current Orientation: House faces West Highest Cooling Load: House faces West Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsoft° 2018 -Oct -0517:18:47 9 Right-Suite®Universa1207717.0.03 RSU20477 +1++ ...R\Documents\wrightsofMare\Katichner\sf15b3.rup Calc=MJB House faces: W Page 1 Main Job #: SF20B4 Performed by Vince Byram for: Cody Puzey 3758 Vellowslones Hwy Idaho Falls, Id 83401 Phone: 208-529-2116 Katchner 601 West 1700 South Logan, Utah 84321 Phone: 435-755-7080 Scale: 1 : 67 Page 1 Right -Su ite® Unive m 12017 17.0.03 RSU20477 2016 -Oct -05 17:19:17 ... g htsoftwa reWartch nerlsfl 5b3, rup 2nd floor Job M SF2064 Performed by Vince Byram for: Cody Puzey 3758 Vellowstones Hwy Idaho Falls, Id 83401 Phone: 208-529-2118 Katchner 601 West 1700 South Logan, Utah 84321 Phone: 435-755-7080 Scale: 1 : 67 Page 2 Right -Su ite® Unive m 12017 17.0.03 RSU20477 2016 -Oct -05 17:19:17 ... g htsoftware\Kartchnerlsf15b3. rup Duct S stem Summa Jeb: S Y � Date: 10/61165N5 Entire House By: Vince Byrarn ° Katchner llnnr np. U an uiwtAp. 801 West 1700 South, Logan, Utah 84321 Phone: 435-755-7080 For: Cody Puzey, Kartchner Homes 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.70 in H2O 0.32 in H2O 0.38 in H2O 0.284 / 0.096 in H2O 0.084 in/100ft 859 cfm 453 ft Cooling 0.70 in H2O 0.32 in H2O 0.38 in H2O 0.284 / 0.096 in H2O 0,084 in/100ft 859 cfm Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Mail Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Rooms h 635 15 7 0.084 6.0 Oxo ShMt 13.0 325.0 st2 Room11 h 856 20 10 0.084 6.0 '0x0 ShMt 13.0 325.0 st2 Room12 c 1743 61 107 0.084 8.0 Oxo ShMt 13.0 325.0 st2 Roomi4 h 587 14 5 0.084 6.0 0x0 ShMt 13.0 325.0 st1 Raom15 c 1440 74 89 0.084 6.0 0x0 ShMt 13.0 325.0 Room18 c 1394 57 86 0.084 6.0 0x0 ShMt 13.0 325.0 st2 Room18 h 1956 46 35 0.084 6.0 0x0 ShMt 13.0 325.0 st2 Room18-B h 1956 46 35 0.084 6.0 0x0 ShMt 13.0 325.0 st2 Rcom5 h 7624 178 149 0.084 8.0 0x0 ShMt 13.0 325.0 st1 Rooms C 1188 55 73 0.084 6.0 0x0 ShMt 13.0 325.0 st2 Rooms -A c 1188 55 73 0.084 6.0 0x0 ShMt 13.0 325.0 st2 Room7 h 3434 '80 43 0.084 6.0 0x0 ShMt 13.0 325.0 st2 Room7-A h 3434 80 43 0.084 6.0 0x0 ShMt 13.0 325.0 st2 Rooms c 1681 78 103 0.084 8.0 0x0 ShMt 1 13.0 325.0 st2 Supply Trunk Detail Table 2016rOct-0517:18:48 wrightSOW Right -Suite® Universal 2017 17.0.03 RSU20477 Pagel ...R\Documents\wrightsoft are\Kaachner\sf15b3.mp Calc=MJ8 House faces: W Trunk Htg Clg DesignE29847 Dian H x W Duct Name Type (cfm) (cfm) FR (in) (in) Material Trunk st2 Peak AVF 593 617 0.084 11.9 8 x 16 ShtMetl SO Peak AVF 191 154 0.084 7.7 8 x 12 ShtMetl 2016rOct-0517:18:48 wrightSOW Right -Suite® Universal 2017 17.0.03 RSU20477 Pagel ...R\Documents\wrightsoft are\Kaachner\sf15b3.mp Calc=MJ8 House faces: W Return Branch Detail Table Name Grill Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb3 0x0 448 381 115.0 0.084 473 10.6 3-3.25x14 3-10x27 SJSp rt1 rb8 Ox 0 57 86 115.0 0.084 74 5.7 14x 12 118 ShMt rt1 rb1 0x0 78 103 115!0 0.084 89 6.1 14x 12 ShMt rt1 rb6 Dx0 81 118 115.0 0.084 372 6.4 3.25x14 10x9 SJSp rt3 rb7 0x0 120 82 115.0 0.084 103 6.5 14x 12 ShMt rb5 0x0 74 89 115.0 0.084 76 5.8 14x 12 ShMt Return Trunk Detail Table 2016 -Oct -05 17:18:48 wrightsOft' Rig hl -Suite® U niv ersal 2017 17.0.03 RSU20477 �..vv-- Page 2 fM1+...R\Documents\wrighlsoftware\Kartchnerlsfi5b3.rup Calc=MJ8 House faces: W Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt1 Peak AVF 665 688 0.084 442 12.4 14 x 16 ShtMetl rt3 Peak AVF 81 118 0.084 76 6.4 14 x 16 ShtMetl rt1 2016 -Oct -05 17:18:48 wrightsOft' Rig hl -Suite® U niv ersal 2017 17.0.03 RSU20477 �..vv-- Page 2 fM1+...R\Documents\wrighlsoftware\Kartchnerlsfi5b3.rup Calc=MJ8 House faces: W