HomeMy WebLinkAboutREPORT REVIEW 1 - 17-00118 - 555 W Mikan Dr - Eden Apartments Site PlanReview Report Current Public Works Review - Site Plan Status: REVISIONS Application Number: 17-00118Permit Details Application Received Date: 03/20/2017 Site Plan Application Approved Date: Application Approved Status: APPROVED 03/20/2017 550 W Mikan Dr Eden Apartments Site Plan Status of Plan Reviews Completed 03/21/2017Public Works Review - Site Plan REVISIONS 03/22/2017Planning and Zoning Review - Site Plan REVISIONS 03/28/2017Fire Department Review - Site Plan REVISIONS Permit Review Status Plan Reviews Still in Progress Public Works Review - Site Plan Planning and Zoning Review - Site Plan Fire Department Review - Site Plan DESCRIPTION COMMENTS STA TUS *Please respond to "REVISIONS" status items, with appropriate comment/documentation as needed! Street REVISIONSNeed details submitted, ie infiltrators, lighting, etc. *Revisions Response : Street REVISIONSTrash enclosures need to be located to allow for right side pickup. *Revisions Response : Water REVISIONSWater line must be extended to University Blvd on 5th W. *Revisions Response : Sewer REVISIONSSW building service can not tie into manhole unless it is 8". *Revisions Response : Sewer REVISIONSWill need profiles for sanitary sewer lines submitted. *Revisions Response : Sewer REVISIONSSSMH2 must be moved west out of asphalt and stubbed to the north. *Revisions Response : Reviewed By: Joel Gray Review Date: 03/21/2017 Plan Review Details joel.gray@rexburg.org Public Works Review - Site Plan Status: REVISIONS Page 1 of 2 Approval of plans does not constitue approval of variance from code Public Works Review - Site Plan (Continued) D ESCRIPTIO N CO MMEN TS STATUS Storm REVISIONSStorm water from roadway must be on separate systems. *Revisions Response : Storm REVISIONSStorm chamber elevations indicate 1 ft difference. Is that accounted for is volume calculations? *Revisions Response : Water REVISIONSCurb Stop for culinary split must be gate valve. *Revisions Response : Water REVISIONS10 ft separation must be maintained from storm system. *Revisions Response : Lighting REVISIONSAdditional street light at each entrance will be required. *Revisions Response : Water N/AWhat are two lines, in center of project, with circles near end, fire hydrants? Suggest more water valves internal than just the one. Storm N/AWill 30" CB accept four 12" storm lines? Storm N/A Sewer N/A Street N/A Plans are approved for a footing/foundation ONLY permit? N/A Street N/APerimeter roads to be separate plans? Page 2 of 2 Approval of plans does not constitue approval of variance from code