Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SPA PLAN - 17-00119 - 555 W Mikan Dr - Eden Apartments Bldg 12 - 37 Units & Club
O P OWN on SPAT R ME J 0 0 I I ro 0 I in LEGEND REFERENCE POOL DRAWS FOR SIZE ®=tIGNT AND LOCATION OF RENNN FLOOR DRAIN ®=SpMMER SIN F.D. iHERP➢Y JEi POOL EQUIPMENT �, p=EGDAtILEN STORAGE ROOM ®=G 9RNL � O=DecwrvG ®•AW0FU �POVREO COPING O ®•OIITTER..N ®•SPAD.N ®=JEi... ® -.pT LEVEt 27'-0" 8" BASIC SPA LAYOUT AND PLOT SCALING 114" v 1' UNLESS CONSTRUCTION PLAN FOR SPA CONSTRUCTION PROJECT: SHEET # 13650 highway 30 West OTNERWIse EDEN APARTMENTS REXBURG, IDAHO Pocatello, Idaho 63201 NOTED LEFT BASIC SPA LAYOUT AND DIMENSIONS n LEFT SPA CUTAWAY LEGEND ©-UcaT OR =ftENRN © =VRCUVM FITTING ® =MWER 0-MEMP JET OE-EOUAWIii ® =GMB MIL tO=1AOGER O=oacwrve <8> FILL l RcV .coPINo ®=OVTTER ORWN ®=GRNN ®= WATER LEVEL RIGHT BASIC SPA LAYOUT AND RIGHT SPA CUTAWAY SPA DATA: SIZE 10'-0" X 20'-0^ WATER DEPTH 3'-0.. SHAPE RECTANGULAR CONSTRUCTION TYPE SHOTCRETE AREA 200 SO. FT. PERIMETER 36' VOLUME 3579 GALLONS MIN. FLOW 39 GPM MAX. FLOW 119 GPM TURNOVER 30 MIN. GENERAL NOTES: SCOPE OF WORK: This spa project is a part of a general construction project being built in Rexburg, Idaho for Eden Inn & Suites facility by Kartchner Commercial Builders, 859 S. Yellowstone Hwy Ste 201, Rexburg, Idaho 83440. All work is under the direct management of this company. Two new spa units are to be installed. The project Includes plans to install two new 10' X 20' spa units in the patio area. This will Include a skimmer, VGB approved main drains, corner steps with handrail, a handicapped spa entry with a dual grab rail, 16 ea. therapy jets, and all associated pumps, filters, control units and all associated piping and drain equipment. Also to be installed is all associated signage and pool maintenance equipment. As General Contractor for the project, Kartchner Commercial Builders, 859 S. Yellowstone Hwy Ste 201, Rexburg, Idaho 83440, Is responsible for compliance with codes and ordinances governing the work. SUBCONTRACTOR NOTES: Mastercraft Pool and Spa will be considered a subcontractor employed by Kartchner Commercial Builders to perform the construction and Installation work. All work will be Inspected and approved. Mastercraft will be responsible to construct two new shotcrete(gunite) spas. Mastercraft will also Install all support equipment In the area designated as "pool equipment" in the Clubhouse building. Mastercraftwill also install all piping and control equipment to support the spas. Mastercraft Pool and Spa will verify all existing conditions and dimensions prior to construction. All written dimensions shall take precedence over scale. Manufacturers specifications for installation of materials shall be followed. Electrical Subcontractor (lo be determined) will be responsible to provide all wiring, controls, conduit, and grounding systems to operate the pool equipment. The wiring will be installed to meet all N.E.C. subpart 680 regulations regarding swimming pool and spa facilities. All work shall also conform to all local and Idaho State regulations regarding this type of facility. A schedule of actual materials required will be outlined in the specifications sheet 94. Plumbing Subcontractor (to be determ l ned) will be responsible to obtain all piping, fittings, and mist. small parts to connect all components of the pool to complete the installation. Plumbing, antl general operation will be tested and approved by Kartchner Commercial Builders. K -1I - Workmanship throughout shall be of the best quality of the trade involved and the General Contractor shall coordinate the work of the various trades to expedite the job in a smooth and continuous process. Electrical and Plumbing contractors as well as Incidental contractors will coordinate work schedules and procedures with Mastercraft Pool and Spa to assure a smooth workflow. STATE OF IDAHO GOVERNING AUTHORITY: The State of Idaho has adopted standards published by The Idaho State Board of Health and Welfare These regulations are contained in IDAPA 16, Title 02, Chapter 14, under rules published as Rules Governing Construction and Operation of Public Swimming Pools and Spas In Idaho. All standards and codes are adopted by reference and apply to all new construction or remodeling or renovation existing facilities. All applicable codes will be referenced to this standard in Nese plans. ADDITIONAL NOTES: SCALING 114" a 1' SPA LAYOUT AND DIMENSIONS UNIL CONSTRUCTION PLAN FOR SPA CONSTRUCTION PROJECT: SHEET # 2 P� 3650 highway 3o West CUTAWAYS NOTHOTEDWISe EDEN APARTMENTS REXBURG, IDAHO Pocatello, Idaho sszo mi,�'aMpm SPA AND JET DRAIN DETAIL NO ILLUSTRATION AVAILABLE DECK DRAIN DETAIL INSTALL SHOTCRETE TYPE SKIMMER AS NOTED IN DRAWING. LID OF SKIMMER SHOULD BE PLACED LEVEL WITH THE DECK SURFACE SO AS NOT TO PRESENT TRIPPING HAZARD. THE EQUALIZER IS TO BE INSTALLED IN THE SPA SEAT WALL AND EQUIPED WITH AN ANTI -ENTRAPMENT COVER THAT IS COMPLIANT WITH THE VIRGINIA GRAEME BAKER POOL AND SPA SAFETY ACT (ANS#APSP 16-2011 AND NSF/ANSI 50-2009a). THE SKIMMER IS TO BE EQUIPPED WITH A FLOAT VALVE AND AN EQUALIZER CHECK VALVE. REFERENCE: 16.02.14.282, 283, 284 285 SKIMMER EQUIPMENT SCHEDULE SKIMMER: PENTAIR 506370 GUNITE SKIMMER W/FLOAT VALVE AND EQUALIZER VALVE AND 506162 EQUALIZER ASSY. OR EQUIV. THE 32" SPA MAIN DRAIN IS A THREE PORT CHANNEL DRAIN TYPE AND IS EQUIPED WITH A PRE -MANUFACTURED PVC SUMP. INSTALL PER MANUFACTURERS INSTRUCTIONS. THE COVER SHALL HAVE BEEN TESTED TO COMPLY WITH THE VIRGINIA GRAEME BAKER POOL AND SPA SAFETY ACT (ANSI/APSP 16-2011 AND NSF/ANS150-2009a. COVER FRAME AND GRATE SHALL BE EQUIPPED WITH STAINLESS STEEL TAMPER PROOFSCREWS. REFERENCE: 16.D2.14.290, 291 292 DRAIN EQUIPMENT SCHEDULE SPA POOL DRAIN: STARGUARD 5001008" DRAIN W/2" SIDE PORT OR EQUIV. INSTALL SPA DECK DRAIN IN 1.625" SLOT IN DECK. SLOPE ALL SURFACES TOWARD DRAIN TO ASSURE NO LOW SPOTS. DRAIN ALL WATER AND DERBIES TO SANITARY SEWER. REFERENCE; 16.02.14.28D, 281 CHANNEL DRAIN: STEGMEYER STEG SDOG FRONTIER DECK DRAIN/GREY OR EQUIV. RIGHT BASIC SPA LAYOUT AND DIMENSIONS LEFT SPA CUTAWAY LEGEND ®=LIGXi RETURN -SKIMMER ® -SKIMMER J�THEAAPY JET L�E=EOUALHER ® =GRAB", O=DE.N.. ®/�=AUTO FILL v -POURED COPIRG ®•GUTTERDRAIN ®=SPA OMAN O=hTDCAE1 ®=WATER LEVEL NOT TO SCALE SPA WALL DETAIL NOT TO SCALE GRIDAND GROUND GRID NOT TO SCALE PA UNDERWATER LIGHT SPA NO DMNE DEPTH MARKERS SPA IS CONSTRUCTED WITH VERTICAL WALLS COMPRISED OF SHOTCRETE 12" WIDE FROM TOP TO BOTTOM OF SPA AND FLOOR ALSO OF SHOTCRETE W THICK. DECKING IS TO BE COMPRISED OF 4" REINFORCED POURED CONCRETE. A ROW OF FROST -PROOF 6!'X 6" CERAMIC TILE WILL BE PLACED AROUND THE PERIMETER OF THE SPA AT THE TOP OF THE WALL. WATERLINE WILL BE 3" BELOW THE TOP OF THE POOL WALL. REFERENCE 16.02.14.090, 091, 100 , 110, 111 STEPS SHALL BE SPACED AS NOTED. A STAINLESS STEEL DECK MOUNTED STAIR RAIL WILL BE INSTALLED AT THE CENTER OF THE STEPS. THE STAIR RAIL SHALL EXTEND OVER BOTTOM STEP OF THE SPA. ALL METAL COMPONENTS WILL BE TIED TO THE GROUNDING SYSTEM AS PER N.E.C. ARTICLE 680. REFERENCE: 16.02.14.120, 124, HANDRAIL SPECIFICATION RAIL ANCHOR BRASS: PERMACAST PS -4019 -BC RAIL ANCHOR BRASS OR EQUIV HANDRAIL: COMMERCIAL CRH -100 HANDRAIL COMM RING RAILS ONLY OR EQUIV. ANCHOR ARSYSR SMITH 34-360A ANCHOR ASSY. RRH-IOD GIBRALTAR OR EQUIV. A UL LISTED UNDERWATER J BOX WILL BE INSTALLED ATA DISTANCE GREATER THAN 4' FROM THE INTERIOR SPA SEAT WALL. A V PVC CONDUIT WILL BE PLACED UNDER SPA DECKING BY THE ELECTRICAL CONTRACTOR TO TERMINATE INA UL LISTED STAINLESS STEEL LIGHT NICHE AND UNDERWATER LIGHT FIXTURE. THE NICHE AND LIGHT ASSEMBLY WILL BE ATTACHED TO THE APPROVED N.E.C. 680 GROUNDING SYSTEM AS WELL AS THE REBAR GRID SYSTEM. LIGHT SHALL BE PLACED AT LEAST 18" AND NOT MORE THAN 36" BELOW THE WATER SURFACE. LIGHT SHOULD ILLUMINATE THE FLOOR AT THE BASE OF THE SPA. REFERENCE 16.02.14.140, 043 NEC 680 UL LISTING SPA LIGHTING SPECIFICATION SPA LIGHT: SPA BRITE 78106100 50 FT. 60W. 120V LIGHT OR EQUIV. NICHE: 79206600 NICHE SPA GUNITE PLASTIC OR EQUIV IMBED e" X 6" FROST -PROOF NON-SKID TILE DEPTH NUMBERS IN POURED COPING WITH CONTRASTING BACKGROUND. INSTALL 6"X 6" FROST PROOF GLAZED CERAMIC TILE WITH 4" CONTRASTING NUMBERS ON VERTICAL WALL IN TILE BAND AT WATERLINE. SPECIFICATION CALLS FOR ALL TILES TO LIST DEPTHS IN METERS AS WELL AS FEET DUE TO THE INTERNATIONAL NATURE OF PERSONS USING THE SPA. REFERENCE: 16.02.14.210, 211 MARKER SPECIFICATION SPA WALL NIARKERS: INL-37-XXXX C6XXXXX 6X6 SMOOTH BW 4"-XFT OR EQUIV. SPA COPING MARKERS: INL-37-XXXX, CBXXXXX 6X6 NON SKID BW 4-XFT OR EQUIV. (3 EA.) #3 CONT ATBOND #3 SPA CUTAWAY REBAR DETAIL (NOT TO SCALE) 2" MAX. DIA. AIR AND WATER LINE. °3"CLEAR FROM REBAR #3 AT 12" EACH WAY SCALING 1140 IS 1- CONSTRUCTION PLAN FOR SPA CONSTRUCTION PROJECT SPA CONSTRUCTION/ UNLESS SHEET # 3 M9SP�61 & S 3650 hlShway 30 Wes! EQUIPMENT SPECIFICATION NOTH OTERED WISE CITY OF IDAHO FALLA, IDAHO FALLS, IDAHO Pocatello, Idaho 83201 NOT --N LEFT SPA CUTAWAY LEGEND ®=LIGXi RETURN -SKIMMER ® -SKIMMER J�THEAAPY JET L�E=EOUALHER ® =GRAB", O=DE.N.. ®/�=AUTO FILL v -POURED COPIRG ®•GUTTERDRAIN ®=SPA OMAN O=hTDCAE1 ®=WATER LEVEL NOT TO SCALE SPA WALL DETAIL NOT TO SCALE GRIDAND GROUND GRID NOT TO SCALE PA UNDERWATER LIGHT SPA NO DMNE DEPTH MARKERS SPA IS CONSTRUCTED WITH VERTICAL WALLS COMPRISED OF SHOTCRETE 12" WIDE FROM TOP TO BOTTOM OF SPA AND FLOOR ALSO OF SHOTCRETE W THICK. DECKING IS TO BE COMPRISED OF 4" REINFORCED POURED CONCRETE. A ROW OF FROST -PROOF 6!'X 6" CERAMIC TILE WILL BE PLACED AROUND THE PERIMETER OF THE SPA AT THE TOP OF THE WALL. WATERLINE WILL BE 3" BELOW THE TOP OF THE POOL WALL. REFERENCE 16.02.14.090, 091, 100 , 110, 111 STEPS SHALL BE SPACED AS NOTED. A STAINLESS STEEL DECK MOUNTED STAIR RAIL WILL BE INSTALLED AT THE CENTER OF THE STEPS. THE STAIR RAIL SHALL EXTEND OVER BOTTOM STEP OF THE SPA. ALL METAL COMPONENTS WILL BE TIED TO THE GROUNDING SYSTEM AS PER N.E.C. ARTICLE 680. REFERENCE: 16.02.14.120, 124, HANDRAIL SPECIFICATION RAIL ANCHOR BRASS: PERMACAST PS -4019 -BC RAIL ANCHOR BRASS OR EQUIV HANDRAIL: COMMERCIAL CRH -100 HANDRAIL COMM RING RAILS ONLY OR EQUIV. ANCHOR ARSYSR SMITH 34-360A ANCHOR ASSY. RRH-IOD GIBRALTAR OR EQUIV. A UL LISTED UNDERWATER J BOX WILL BE INSTALLED ATA DISTANCE GREATER THAN 4' FROM THE INTERIOR SPA SEAT WALL. A V PVC CONDUIT WILL BE PLACED UNDER SPA DECKING BY THE ELECTRICAL CONTRACTOR TO TERMINATE INA UL LISTED STAINLESS STEEL LIGHT NICHE AND UNDERWATER LIGHT FIXTURE. THE NICHE AND LIGHT ASSEMBLY WILL BE ATTACHED TO THE APPROVED N.E.C. 680 GROUNDING SYSTEM AS WELL AS THE REBAR GRID SYSTEM. LIGHT SHALL BE PLACED AT LEAST 18" AND NOT MORE THAN 36" BELOW THE WATER SURFACE. LIGHT SHOULD ILLUMINATE THE FLOOR AT THE BASE OF THE SPA. REFERENCE 16.02.14.140, 043 NEC 680 UL LISTING SPA LIGHTING SPECIFICATION SPA LIGHT: SPA BRITE 78106100 50 FT. 60W. 120V LIGHT OR EQUIV. NICHE: 79206600 NICHE SPA GUNITE PLASTIC OR EQUIV IMBED e" X 6" FROST -PROOF NON-SKID TILE DEPTH NUMBERS IN POURED COPING WITH CONTRASTING BACKGROUND. INSTALL 6"X 6" FROST PROOF GLAZED CERAMIC TILE WITH 4" CONTRASTING NUMBERS ON VERTICAL WALL IN TILE BAND AT WATERLINE. SPECIFICATION CALLS FOR ALL TILES TO LIST DEPTHS IN METERS AS WELL AS FEET DUE TO THE INTERNATIONAL NATURE OF PERSONS USING THE SPA. REFERENCE: 16.02.14.210, 211 MARKER SPECIFICATION SPA WALL NIARKERS: INL-37-XXXX C6XXXXX 6X6 SMOOTH BW 4"-XFT OR EQUIV. SPA COPING MARKERS: INL-37-XXXX, CBXXXXX 6X6 NON SKID BW 4-XFT OR EQUIV. (3 EA.) #3 CONT ATBOND #3 SPA CUTAWAY REBAR DETAIL (NOT TO SCALE) 2" MAX. DIA. AIR AND WATER LINE. °3"CLEAR FROM REBAR #3 AT 12" EACH WAY SCALING 1140 IS 1- CONSTRUCTION PLAN FOR SPA CONSTRUCTION PROJECT SPA CONSTRUCTION/ UNLESS SHEET # 3 M9SP�61 & S 3650 hlShway 30 Wes! EQUIPMENT SPECIFICATION NOTH OTERED WISE CITY OF IDAHO FALLA, IDAHO FALLS, IDAHO Pocatello, Idaho 83201 NOT 0 0 0 1 0 PIPE ROUTING MAY VARY FROM DRAWING REFERENCE POOL DRAWINGS FOR SIZE AND LOCATION OF FLOOR DRAIN JETCRNNAL' 4CC Q m N a Q w i JET RET. A<' SH� JET DRNN B G' EF JETRETCT AT CIRC RET. I LIR. CANNY SPA i EQUIP. SERVICE POOL EQUIPMENT Ln i — SF SPA 2 EQUIP. EDEN APARTMENTS CLUBHOUSE BASEMENT 0 0 0 EQUIPMENT ROOM LEGEND SH =SPA HEATER SC = SPA CIRCULATING PUMP GJ =SPA JET PUMP SF - SPA SAND FILTER V =VALVE DR=DRAIN JS -JET SWITCH SS -SPA PUMP SWITCH CC=CLORINATOR CONTROL AT=ACID TANK CT=CHLORINETANK EST - EMERGENCY SHUTDOWN LEGEND Q- LIGHT < -RETURN ® =SKIMMER <Z�_THERAPYJET O=EQUALIZER =GRAB RAIL OD =DECKING ®=AUTO FILL POURED COPING ®=GUTTER DRAIN ®=SPA DRAIN ,Q>= JET DRAIN ® = WATER LEVEL PODUSPA EQUIPMENT SCHEDULE BACKWASH VALVE: PENTAIR 2610502" HIFLOW PAC -FAB HI FLOW OR EQUIV. SPA HEATER: PENTAIR 460732 MASTERTEMP 250 NAT. OR EQUIV. SPA FILTER: PENTAIR 160318 CLEAN&CLEAR 200 SOFT FILTER OR EQUIV. SPA JET PUMP: PENTAIR 011516 WFLO 3HP WFE-12206-230V 1 SPD OR EQUIV. SPA CIRCULATION PUMP: PENTAIR011516WFL03HPWFE-12208-23OV1SPDOREQUIV. SCALING 114" = 1' EQUIPMENT LAYOUT AND PIPING UNLESS CONSTRUCTION PLAN FOR SPA CONSTRUCTION PROJECT: SHEET # 4 MBSl�b13 3650 highway SO Wes! DIAGRAMIEQUIPMENTSPECIFICATION OTHERWISE EDEN APARTMENTS REXBURG IDAHO Pocatello, Idaho 83201 NOTED