HomeMy WebLinkAboutRESCHECK - 17-00120 - 555 W Mikan Dr - Eden Apartments Bldg 1 - 30 UnitsCOMcheck Software Version 4.0.0
Envelope Compliance Certificate
Project Information
Energy Code:
2012 IECC
Project Title:
Eden Apartments
Location:
Rexburg, Idaho
Climate Zone:
6b
Project Type:
New Construction
Vertical Glazing / Wall Area:
13%
Construction Site: Owner/Agent:
950 Mikan Drive
Rexburg„ ID 823440
Building Area
Floor Area
1 -MAIN FLOOR (Multifamily) : Residential 7234
2 -2ND FLOOR (Multifamily) : Residential 7234
3 -3RD FLOOR (Multifamily) : Residential 7234
Designer/Contractor:
Additional Efficiency Package
High efficiency HVAC. Systems that do not meet the performance requirement will be identified in the mechanical requirements checklist
report.
Envelope Assemblies
Assembly
Roof 1: Attic Roof with Wood Joists, [Bldg. Use 3 - 3RD FLOOR]
Exterior Wall 1: Wood -Framed, 16" o.c., [Bldg. Use 3 - 3RD FLOOR]
Window 1: Vinyl/Fiberglass Frame:Operable, Pert. Specs.: Product ID
na, SHGC 0.70, [Bldg. Use 3 - 3RD FLOOR] (c)
Door 1: Other Door, Swinging, [Bldg. Use 3 - 3RD FLOOR]
Exterior Wall 2: Wood -Framed, 16" o.c., [Bldg. Use 2 - 2ND FLOOR]
Window 2: Vinyl/Fiberglass Frame:Operable, Perf. Specs.: Product ID
na, SHGC 0.70, [Bldg. Use 2 - 2ND FLOOR] (c)
Door 2: Other Door, Swinging, [Bldg. Use 2 - 2ND FLOOR]
Exterior Wall 3: Wood -Framed, 16" o.c., [Bldg. Use 1 - MAIN FLOOR)
Window 3: Vinyl/Fiberglass Frame:Operable, Perf. Specs.: Product ID
na, SHGC 0.70, [Bldg. Use 1 - MAIN FLOOR] (c)
Door 3: Other Door, Swinging, [Bldg. Use 1 - MAIN FLOOR]
Floor 1: Wood -Framed, [Bldg. Use 3 - 3RD FLOOR]
Floor 2: Wood -Framed, [Bldg. Use 2 - 2ND FLOOR]
Floor 3: Slab -On -Grade: Unheated, Vertical 2 ft., [Bldg. Use 2 - 2ND
Gross Area Cavity Cont. Proposed Budget U -
or R -Value R -Value U -Factor Factor(.)
Perimeter
7234 49.0 0.0 0.021 0.021
5931 23.0 0.0 0.059 0.051
796 --- --- 0.300 0.430
160
---
---
0.025
0.370
5931
23.0
0.0
0.059
0.051
796
--
---
0.300
0.430
160
--
---
0.025
0.370
5931
23.0
0.0
0.059
0.051
796
--
---
0.300
0.430
160
---
---
0.025
0.370
7234
0.0
40.0
0.023
0.033
7234
0.0
40.0
0.023
0.033
659
--
10.0
0.550
0.520
(a) Budget U -factors are used for software baseline calculations ONLY, and are not code requirements.
(b) 'Other'components require supporting documentation for proposed U -factors.
(c) Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation.
(d) Slab -On -Grade proposed and budget U -factors shown in table are F -factors.
Project Title: Eden Apartments Report date: 04/17/17
Data filename: C:\Users\Guy\Documents\COMcheck\Eden 30 unit Apartment Buildings.cck Page 1 of 9
Envelope Compliance Statement
Compliance Statement: The proposed envelope design represented in this document Is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed envelope systems have been
designed to meet the 2012 IECC requirements in COMcheck Version 4.0.0 and to comply with the mandatory requirements listed
in the Inspection Checklist.
Date
Project Title: Eden Apartments Report date: 04/17/17
Data filename: C:\Users\Guy\Documents\COMcheck\Eden 30 unit Apartment Buildings.cck Page 2 of 9
COMcheck Software Version 4.0.0
Inspection Checklist
Energy Code: 2012 IECC
Requirements: 0.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
2012 :ECC Plan Review
Complies? Comments/Assumptions
C103.2
;Plans and/or specifications provide all❑Complies
[PR111
:information with which compliance❑Does
Not
; can be determined for the building
;envelope and document where
❑Not Observable;
I❑Not Applicable
:exceptions to the standard are
;
;claimed.
0406
.Plans, specifications, and/or
❑Complies
[PR911
:calculations provide all Information
j❑Does Not
:with which compliance can be
:[]Not Observable;
(determined for the additional energy
:efficiency package options.❑Not
Applicable
0402.3.1
;Vertical fenestration area <= 30
;❑Complies
[PR1011
; percent of the gross above -grade wall
;❑Does Not
:area.
;❑Not Observable'
❑Not Applicable
04023,1
jSkylight area <= 3 percent of the
:❑Complies
[PR1111
;gross roof area.❑Does
Not
❑Not Observable:
'
;❑Not Applicable j
C402.3.2.
(Areas with obstructions that block❑Complies
2
(direct beam sunlight on >= 1/2 of the
:❑Does Not :
[PR15]1
:roof over the enclosed area for more
: :
:❑Not Observable;
:than 1,500 daytime hours per year
:between 8 am and 4 pm.
I❑Not Applicable
Additional Comments/Assumptions:
1 I High Impact (Tier 1) Medium Impact (Tier 2) 13 1 Low Impact (Tier 3)
Project Title: Eden Apartments Report date: 04/17/17
Data filename: C:\Users\Guy\Documents\COMcheck\Eden 30 unit Apartment Buildings.cck Page 3 of 9
Section
#
Footing / Foundation
Plans Verified Field Verified
Complies. Comments/Assumptions
& Req .ID
Inspection
Value Value
C402.2.6 'Slab
edge insulation R-value.
R- R-_❑Complies
;See the envelope Assemblies
[FO31z
❑ Unheated ❑ Unheated❑Does
Not table for values.
❑ Heated❑Heated❑Not
Observable
j❑Not Applicable
C303.2
!Slab edge insulation installed per❑Complies
i;
[FO412
manufacturer's instructions.
�r
❑Does Not
r
❑Not Observable
'.❑Not Applicable
0402.2.6 ;Slab
edge insulation
ft ft❑Complies
See the Envelope Assemblies
[FO5]2 (depth/length.
Slab insulation❑Does
Not ;table for values.
;extending
away from building is
Observable
(covered by pavement or >= 10❑Not
'.'.❑Not
Applicable
inches of soil.
0403.2.7,
Exterior insulation protected❑Complies
C408.2.8,
!against damage, sunlight,❑Does
Not
C404.5
;moisture, wind, landscaping and
❑Not Observable I
[FO611
;equipment maintenance',
;activities.
',.❑Not Applicable
C402,2.8
Bottom surface of floor structures
Complies ;See the Envelope Assemblies
[FO12]3.
incorporating radiant heating
Roes Not :table for values.
•,insulated to >=R-3.5.
'..❑Not
Observable
❑Not Applicable
Additional Comments/Assumptions:
11 High Impact (Tier 1) Medium Impact (Tier 2) 1z,fl Low Impact (Tier 3)
Project Title: Eden Apartments Report date: 04/17/17
Data filename: C:\Users\Guy\Documents\COMcheck\Eden 30 unit Apartment Buildings.cck Page 4 of 9
Section
#
Framing / Rough -In Inspection
Plans Verified
Value
Field Verified
Value
Complies? Comments/Assumptions
& Reci.ID
C402.4.1,
;The building envelope contains a❑Complies
C402.4.2
:continuous air barrier that is
-❑Does
Not
[FR161'
;sealed in an approved manner
Observable
:and either constructed or tested❑Not
in an approved manner. Air
❑Not Applicable j
:barrier penetrations are sealed in
-.
:an approved manner.
C402.4.3,
; Factory -built fenestration andzaap❑Complies
C402.4.4
!doors are labeled as meeting air
'I]Does
Not
[FR1813
�', leakage requirements.
❑Not Observable
❑Not Applicable
C402.4.7
!Vestibules are installed on all
'..
.❑Complies
[FR17]3
'building entrances. Doors have❑Does
Not
self-closing devices.
'.. ',..❑Not
Observable
❑Not Applicable
0402.33,
Vertical fenestration U -Factor.
'.. U- U-
❑Complies see the envelope Assemblies
C402.3.4❑Does
Not table for values.
[FR8]'❑Not
Observable
❑Not Applicable
04023.3
(Vertical fenestration SHGC value.!
SHGC: SHGC:❑Complies
',See the envelope assemblies
[FR1011❑Does
Not table for values.
I❑Not Observable
❑Not Applicable
C303.1.3 .;Fenestration
products rated in
,❑Complies
[FR12j2
r!accordance with NFRC.
-
❑Does Not
❑Not Observable
''.
:❑Not Applicable
C303.1.3
Fenestration products are❑Complies
[FR13]1
'certified as to performance labels
-❑Does
Not
or certificates provided.
❑Not Observable I
❑Not Applicable
C402.2.7
U -factor of opaque doors
U- '.. U-
❑Complies ;See the envelope Assemblies
[FR141'
'associated with the building
_ E Swinging ❑ Swinging',❑Does
Not (table for values.
thermal envelope meets
❑ Nonswinging ❑ Nonswinging
;❑Not Observable ;
requirements.
❑Not Applicable
Additional Comments/Assumptions:
1 I High Impact (Tier 1) Medium Impact (Tier 2) 13 1 Low Impact (Tier 3)
Project Title: Eden Apartments Report date: 04/17/17
Data filename: C:\Users\Guy\Documents\COMcheck\Eden 30 unit Apartment Buildings.cck Page 5 of 9
Mechanical Rough -in Inspection I Complies?
Stair and elevator shaft vents have ❑Complies
motorized dampers that automatically []Does Not
close. ❑Not Observable;
C402,4.5. ;Outdoor air and exhaust systems have;❑Complies
2 i motorized dampers that automatically I❑Does Not
[ME58]3 ;shut when not In use and meet
maximum leakage rates. Check❑Not Observable
!gravity dampers where allowed. ;❑Not Applicable
Additional Comments/Assumptions:
Comments/Assumptions
1 I High Impact (Tier 1) Medium Impact (Tier 2) 3 1 Low Impact (Tier 3)
Project Title: Eden Apartments Report date: 04/17/17
Data filename: C:\Users\Guy\Documents\COMcheck\Eden 30 unit Apartment Buildings.cck Page 6 of 9
Section
#
Insulation Inspection
Plans Verified
Value
Field Verified
Value
Complies?
Comments/Assumptions
& Re .ID
C402.4.1.
:All sources of air leakage in the
❑Complies
1
-:building thermal envelope are❑Does
Not
[IN111
:sealed, caulked, gasketed,
- :❑Not
Observable I
:weather stripped or wrapped with
moisture vapor -permeable
!❑Not
Applicable
:wrapping material to minimize air'
leakage.
C402.4.2.
;Roof R -value. For some ceiling
R- R -❑Complies
see the Envelope Assemblies
1
:systems, verification may need to.
❑Above deck ❑Above deck
Not table for values.
[IN211
;occur during Framing Inspection.
❑ Metal 1 ❑ Metal
❑Not Observable
i
❑ Attic ❑ Attic❑Not
Applicable
C303.2
;Roof insulation installed per❑Complies
[IN311
manufacturer's instructions.❑Does
Not
;Blown or poured loose -fill
-
:.insulation is installed only where
❑Not Observable
:the roof slope is <=3 in 12.
!❑Not
Applicable
pp
C303.2
;Above -grade wall insulation
'..❑Complies
[IN7]1
installed per manufacturer's'❑Does
Not
instructions.
:.❑Not
Observable
[]Not Applicable
C402.2.5
! Floor insulation R -value.
R- R-
❑Complies ;see the Envelope Assemblies
[INS]1
;❑
Mass ❑ Mass
C]Does Not table for values.
❑ Steel ❑ Steel
;❑Not Observable
I
❑ Wood I ❑ Wood
❑Not Applicable
C303.2
;Floor insulation installed per
❑Complies
[IN9]1
!manufacturer's instructions.
❑Does Not
❑Not Observable
❑Not Applicable
C303.1
:Building envelope insulation is
❑Complies
[IN10]2
labeled with R -value or insulation
❑Does Not
;certificate providing R -value and
;other relevant data.❑Not
Observable ;
-
❑Not Applicable
C303.2.1
Exterior insulation is protected '..
❑Complies
[IN1412
)from damage with a protective
❑Does Not
material. Verification for exposed
'..
Observable ;
foundation insulation may need❑Not
to occur during Foundation
❑Not Applicable
j Inspection.
C402.2.1
!Insulation intended to meet the
❑Complies
[:N171'
goof insulation requirements
-
❑Does Not
;cannot be installed on top of a
Observable'
'suspended ceiling. Mark this❑Not
!. requirement compliant if❑Not
Applicable
:insulation is Installed accordingly..:
Additional Comments/Assumptions:
1 High Impact (Tier 1) 1 Te Impact (Tier 2) 13 1 Low Impact (Tier 3)
Project Title: Eden Apartments Report date: 04/17/17
Data filename: C:\Users\Guy\Documents\COMcheck\Eden 30 unit Apartment Buildings.cck Page 7 of 9
20121ECC Final Inspection Complies? Comments/Assumptions
C402.4.6 jWeatherseals installed on all loading ❑Complies
[FI37]1 dock cargo doors. ❑Does Not
❑Not Observable
❑Not Applicable
C402.4.8
!Recessed luminaires in thermal
;LJComplies
[F126 ]3
!envelope to limit infiltration and be IC❑Does
Not
!rated and labeled. Seal between
Observable
;interior finish and luminaire housing.❑Not
❑Not Applicable
0406
Efficient HVAC performance, efficient
❑Complies
[FI3411
lighting system, or on-site supply of❑Does
Not
i renewable energy consistent with
;what is shown the approved plans.
,
Observable
;n Nn« An..lirohle
Additional Comments/Assumptions:
11 High Impact (Tier 1) #'2„. Medium Impact (Tier 2) 3S1 LOW Impact (Tier 3)
Project Title: Eden Apartments Report date: 04/17/17
Data filename: C:\Users\Guy\Documents\COMcheck\Eden 30 unit Apartment Buildings.cck Page 8 of 9
Project Title: Eden Apartments Report date: 04/17/17
Data filename: C:\Users\Guy\Documents\COMcheck\Eden 30 unit Apartment Buildings.cck Page 9 of 9