Loading...
HomeMy WebLinkAboutRESCHECK - 17-00121 - 555 W Mikan Dr - Eden Apartments Bldg 2 - 42 UnitsCOMcheck Software Version 4.0.0 Envelope Compliance Certificate Project Information Energy Code: 2012 IECC Project Title: Eden Apartments Location: Rexburg, Idaho Climate Zone: 6b Project Type: New Construction Vertical Glazing /Wall Area: 16% Construction Site: Owner/Agent: 950 Mikan Drive Rexburg,, ID 83440 Building Area Floor Area 1 -MAIN FLOOR (Multifamily): Residential 10910 2 -2ND FLOOR (Multifamily) : Residential 10910 3 -3RD FLOOR (Multifamily): Residential 10910 Designer/Contractor: Additional Efficiency Package High efficiency HVAC. Systems that do not meet the performance requirement will be identified in the mechanical requirements checklist report. Envelope Assemblies Assembly Gross Area Cavity Cont. Proposed Budget U. or R -Value R -Value U -Factor Factorm Perimeter Roof 1: Attic Roof with Wood Joists, [Bldg. Use 3 - 3RD FLOOR] 10910 49.0 0.0 0.021 0.021 Exterior Wall 1: Wood -Framed, 16" o.c., [Bldg. Use 3 - 3RD FLOOR] 7974 23.0 0.0 0.059 0.051 Window 1: Vinyl/Fiberglass Frame:Operable, Perf. Specs.: Product ID 1286 --- --- 0.300 0.430 na, SHGC 0.70, [Bldg. Use 3 - 3RD FLOOR] (c) Door 1: Other Door, Swinging, [Bldg. Use 3 - 3RD FLOOR] 240 --- --- 0.025 0.370 Exterior Wall 2: Wood -Framed, 16" o.c., [Bldg. Use 2 - 2ND FLOOR] 7974 23.0 0.0 0.059 0.051 Window 2: Vinyl/Fiberglass Frame:Operable, Pert. Specs.: Product ID 1286 --- --- 0.300 0.430 na, SHGC 0.70, [Bldg. Use 2 - 2ND FLOOR] (c) Door 2: Other Door, Swinging, [Bldg. Use 2 - 2ND FLOOR] 240 --- --- 0.025 0.370 Exterior Wall 3: Wood -Framed, 16" o.c., [Bldg. Use 1 - MAIN FLOOR] 7974 23.0 0.0 0.059 0.051 Window 3: Vinyl/Fiberglass Frame:Operable, Pert. Specs.: Product ID 1286 --- --- 0.300 0.430 na, SHGC 0.70, [Bldg. Use 1 - MAIN FLOOR] (c) Door 3: Other Door, Swinging, [Bldg. Use 1 - MAIN FLOOR] 240 --- --- 0.025 0.370 Floor 1: Wood -Framed, [Bldg. Use 3 - 3RD FLOOR] 10910 0.0 40.0 0.023 0.033 Floor 2: Wood -Framed, [Bldg. Use 2 - 2ND FLOOR] 10910 0.0 40.0 0.023 0.033 Floor 3: Slab-On-Grade:Unheated, Vertical 2 ft., [Bldg. Use 2 - 2ND 886 --- 10.0 0.550 0.520 FLOOR] (d) (a) Budget U -factors are used for software baseline calculations ONLY, and are not code requirements. (b) 'Other components require supporting documentation for proposed U -factors. (c) Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. (d) Slab -On -Grade proposed and budget U -factors shown in table are F -factors. Project Title: Eden Apartments Report date: 04/17/17 Data filename: C:\Users\Guy\Documents\COMcheck\Eden 42 unit Apartment Buildings.cck Page 1 of 9 Envelope Compliance Statement Compliance Statement., The proposed envelope design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed envelope systems have been designed to meet the 2012 IECC requirements in COMcheck Version 4.0.0 and to comply with the mandatory requirements listed in the Inspection Checklist. Name - Title Signature Project Title: Eden Apartments Report date: 04/17/17 Data filename: C:\Users\Guy\Documents\COMcheck\Eden 42 unit Apartment Buildings.cck Page 2 of 9 COMcheck Software Version 4.0.0 Inspection Checklist Energy Code: 2012 IECC Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen, For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. 2012 IECC Plan Review Complies? Comments/Assumptions C103.2 !Plans and/or specifications provide all❑Complies [PR111 : information with which compliance ;❑Does Not .can be determined for the building :❑Not Observable! ;envelope and document where :exceptions to the standard are ;❑Not Applicable :claimed. C406 -'.Plans, specifications, and/or❑Complies [PR911 calculations provide all information ❑Does Not ;with which compliance can be (determined for the additional energy❑Not : Observable :efficiency package options. I❑Not Applicable C402.3.1 'Vertical fenestration area <= 30❑Complies [PRIO]1 ; percent of the gross above -grade wall ;❑Does Not ;area. ❑Not Observable :[]Not Applicable 0402.3.1 (Skylight area <= 3 percent of the [Complies [PR11]1 :gross roof area. ❑Does Not I❑Not Observable I ❑Not Applicable C4023.2. (Areas with obstructions that block❑Complies 2 (direct beam sunlight on >= 1/2 of the :❑Does Not i [PR1511 !;roof over the enclosed area for more :❑Not Observable; (than 1,500 daytime hours per year :. between 8 am and 4 pm. ;❑Not Applicable ; Additional Comments/Assumptions: 1 I High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 13, 1 low Impact (Tier 3) Project Title: Eden Apartments Report date: 04/17/17 Data filename: C:\Users\Guy\Documents\COMcheck\Eden 42 unit Apartment Buildings,cck Page 3 of 9 Section # Footing / Foundation Plans Verified Field Verified Complies? Coin ments/Assumptions & Req.ID Inspection Value Value C402 rSlab edge insulation R -value. R- R- :❑Complies .See the Envelope Assemblies [FO31.;' ;❑ Unheated ❑ heated Not table for values. El Heated E] Heated j❑Not Observable 1 ':� j❑Not Applicable 0303.2 ;Slab edge insulation installed per .� '�' ❑Complies [F04 12 i manufacturer's instructions, ❑Does Not `,❑Not Observable ❑Not Applicable 0402.2.6 ;Slab edge insulation ft ft Complies ;See the Envelope Assemblies [F05 12 :depth/length. Slab insulation❑Does Not (table for values. ;extending away from building is 'covered ❑Not Observable by pavement or >= 10 inches of soil.❑Not Applicable C403.2.7, Exterior insulation protected ❑Complies C408,2.8, 'against damage, sunlight, ❑Does Not C4045 moisture, wind, landscaping and - ❑Not Observable [F06]1 .equipment maintenance T ❑Not Applicable activities. -,- e s3 rx` C402.2.8;. , Bottom surface of floor structures ❑Complies ;See the Envelope Assemblies [FO12]3 incorporating radiant heating ❑Does Not ;table for values. - :insulated to >=R-3.5. []Not Observable -; .y , >W„�, _ _.ter ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact (Tier 1) 'r.g Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Eden Apartments Report date: 04/17/17 Data filename: C:\Users\Guy\Documents\COMcheck\Eden 42 unit Apartment Buildings.cck Page 4 of 9 Section #I Framing / Rough -In Inspection Plans Verified Value Field Verified Value Complies? EComments/AssumptionsmmtI/Assumptions & Req. ID C402.4.1, ;The building envelope contains a❑Complies C402.4.2 (continuous air barrier that is : ❑Does Not [FR16]1 ;sealed in an approved manner '..❑Not land either constructed or tested Observable lin an approved manner. Air❑Not -' Applicable ;barrier penetrations are sealed in :an approved manner. C402.4.3, ;Factory -built fenestration and '..❑Complies 0402.4.4 ,doors are labeled as meeting air ❑Does Not [FR18]3 leakage requirements. ][]Not Observable {❑Not Applicable 0402.4.7 !Vestibules are installed on all '..',❑Complies [FR1713 building entrances. Doors have❑Does Not self-closing devices. ❑Not Observable ❑Not Applicable C402.3.3, ;Vertical fenestration U -Factor. U- '.. U_ Complies ;see the Envelope Assemblies 0402.3.4❑Does Not table for values. [FR811❑Not Observable ❑Not Applicable 0402.3.3 ;Vertical fenestration SHGC value. SHGC:_ SHGC:_ :❑Complies ;See the Envelope Assemblies [FR1011❑Does Not ;table for values. :[--]Not Observable ❑Not Applicable C303.1.3 ;Fenestration products rated in '..❑Complies [FR1212 :accordance with NFRC. ',. l❑Does Not ❑Not Observable ❑Not Applicable j C303.1.3 ;Fenestration products are ❑Complies [FR1311 :certified as to performance labels❑Does Not or certificates provided. ❑Not Observable j❑Not Applicable C402.2.7 U -factor of opaque doors U- U- ❑Complies ;Seethe Envelope Assemblies [FR1412 'associated with the building ❑ Swinging ❑ Swinging ',❑Does Not ; table for values. ;thermal envelope meets ❑ Nonswinging ; ❑ Nonswinging❑Not Observable I ;requirements. j❑Not Applicable Additional Comments/Assumptions: 1 I High Impact (Tier 1) 1. Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3) Project Title: Eden Apartments Report date: 04/17/17 Data filename: C:\Users\Guy\Documents\COMcheck\Eden 42 unit Apartment Buildings.cck Page 5 of 9 Mechanical Rough -In Inspection I Complies? I Comments/Assumptions C402.4.5. Stair and elevator shaft vents have 1 motorized dampers that automatically [ME313 close. s Not Observable; C402.4.5. Outdoor air and exhaust systems have ILJComplies 2 motorized dampers that automatically❑Does Not [ME5813 shut when not in use and meet maximum leakage rates. Check❑Not Observable: gravity dampers where allowed.❑Not Applicable Additional Comments/Assumptions: 111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: Eden Apartments Report date: 04/17/17 Data filename: C:\Users\Guy\Documents\COMcheck\Eden 42 unit Apartment Buildings.cck Page 6 of 9 Section # Insulation Inspection plans Verified Value Field Verified Value Complies? Coin me nts/Assumptions & Req.ID C402.4.1. :All sources of air leakage in the '.. ❑Complies 1 building thermal envelope are '.. ❑Does Not [IN111 :sealed, caulked, gasketed, Observable f :weather stripped or wrapped with moisture vapor-permeable❑Not .❑Not Applicable : ;wrapping material to minimize air (leakage. C402.4.2. ;Roof R -value. For some ceiling ; R- R- ❑Complies :see the Envelope Assemblies 1 :systems, verification may need to ❑Above deck ❑ Above deck Does Not ;table for values. [IN211 ;occur during Framing Inspection. ❑ Metal ❑ Metal❑Not Observable ❑ Attic ❑ Attic❑Not Applicable 0303.2 ;Roof insulation installed peri; ': s` 4"tea a:�`•.,' - -❑Complies [IN311 :manufacturer's instructions. ❑Does Not :Blown or poured loose -fill ;insulation is installed only where ❑Not Observable ahe roof slope is <=3 in 12.❑Not Applicable C303.2 ;Above -grade wall insulation - '.'❑Complies [IN711 :installed per manufacturers ❑Does Not ;instructions. Not Observable � ❑❑Not ' Applicable C402.2.5 Floor insulation R -value. R- R -❑Complies ;see the Envelope Assemblies [IN8]2 j ❑Mass ❑ Mass ;❑Does Not ;table for values. ❑Steel ; ❑ Steel ;❑Not Observable ❑ Wood ❑ Wood ;❑Not Applicable C303.2 Floor insulation installed per '❑Complies [IN9]2 manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable 0303.1 Building envelope Insulation is ❑Complies [IN10]2 labeled with R -value or insulation❑Does Not !certificate providing R -value and '.. I❑Not Observable other relevant data. j❑Not Applicable C303.2.1 ;Exterior insulation is protected '.. I❑Complies [IN14]2 :from damage with a protective ❑Does Not material. Verification for exposed Observable l ',to foundation Insulation may need❑Not occur during Foundation❑Not Applicable : ;Inspection. C402.2.1 Insulation intended to meet the '..❑Complies [IN17]3 :roof insulation requirements ❑Does Not :cannot be installed on top of a ❑Not Observable ; (suspended ceiling. Mark this jrequirement compliant if ❑Not Applicable insulation is installed accordingly. Additional Comments/Assumptions: 1 I High Impact (Tier 1) DZI Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Eden Apartments Report date: 04/17/17 Data filename: C:\Users\Guy\Documents\COMcheck\Eden 42 unit Apartment Buildings.cck Page 7 of 9 0121ECC Final Inspection Complies? Comments/Assumptions C402.4.6 ; Weatherseals installed on all loading ❑Complies [FI37]1 dock cargo doors.❑Does Not ❑Not Observable: ❑Not Applicable C402.4.8 ;Recessed luminaires in thermal❑Complies [FI26]3 :envelope to limit infiltration and be IC I❑Does Not :rated and labeled. Seal between Observable; ;interior finish and luminaire housing.❑Not ❑Not Applicable C406 Efficient HVAC performance, efficient❑Complies [F13411 lighting system, or on-site supply of❑Does Not ; renewable energy consistent with !❑Not Observable what is shown the approved plans. ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact (Tier 1) Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Eden Apartments Report date: 04/17/17 Data filename: C:\Users\Guy\Documents\COMcheck\Eden 42 unit Apartment Buildings.cck Page 8 of 9 Project Title: Eden Apartments Report date: 04/17/17 Data filename: C:\Users\Guy\Documents\COMcheck\Eden 42 unit Apartment Buildings,cck Page 9 of 9