Loading...
HomeMy WebLinkAboutPLANS LAYOUT REDLINED - 16-00306 - 593 S Hidden Valley Rd - SFR0 I N I M 80'-0" DIMENSION MAIN FLOOR PLAN SCALE: 1/4"=I' -O" GENERAL CONSTRUCTION NOTES -EXTERIOR WALLS 2X6 NOMINAL STUD FRAMING AT 16" O.C. BATT INSULATION TO REQUIRED 'R' VALUE BY LOCAL CODE • INTERIOR WALLS 2X4 NOMINAL STUD FRAMING AT 16" O.C. .PROVIDE ATTIC INSULATION AND VENTIUAT10N IN ACCORDANCE TO LOCAL CODE. • PROVIDE 12X12 ATTIC VENTS W/ INSECT SCREEN, TYPICAL •5/6" TYPE 'X' GYPSUM BOARD REQURED TO SEPARATE GARAGE FROM LIVING SPACES. • 20 MINUTE FIRE RATED DOOR REQUIRED FROM GARAGE TO HOUSE. • ALL FOOTING DEPTH TO BE DETERMINED BY LOCAL CODE WINDOWS & DOOR NOTES • ALL WINDOWS ARE INSULATED AND WEATHERSTRIPPED VERIFY CODE EGRESS WINDOW REQUIREMENTS PRIOR TO CONSTRUCTION •PROVIDE TEMPERED GLASS WHERE REQUIRED • VERIFY SILL HEIGHT ABOVE TUBS AND COUNTERS TO ACCOMMODATE TRIM AND BACKSPLASH • VERIFY WINDOW AND DOOR SIZES WITH CHOSEN MANUFACTURE PRIOR TO CONSTRUCTION. ADJUST AS NECESSARY. Reviewed for Code Compliance 44;6." *Building Inspector 00 W 14'-0" 16'-0" z �- LLI 0 47'-0" (/) 0 W 19'-0" 3'-10" 6'-4" 3'-10" 3'-9" 8'-6" 3'-9" 3'-8" 11'-8" 3'-8" 12'-7" 6'-4" 9'-1" w Lij z —I _ P2 F= w C 1 < - o 11856 6070 o N I O O O O KITCHEN aD { MASTER BEDROOM N I 8070 { 2'-s �( ld-�- 0 I 5-10" 3-7" 3-8" I 0 � 0 I � C o GRE4T ROOM i — — I , PANTRY KITC EN L I I PROVIDE 5/8" GYP BIRD. TTIC ACCES BETWEEN GARAGE AND I { LIVING SPACE ON ALL O O { BEAMS,WALL, & CEILINGS -------------J { NAIL ® 6" O.0 WITH (1) ENSUITE •. ; �/ .I 00 I I COAT FIRETAPE MIN. GARAGE 1 .1 3'- 0" 7 -0" 1 6'-0" GSI ✓� Sem e 1 YlC1�rl� / I \� r------ ----- � 6' 4" CONC. SLAB -PER N LAUNDRY ROOM W/ 1/8 1' 0" { I 3070 SLOPE TO FRONT MUDRCOM 2670 3070 I ENTRY I WIC I 0 c o AT ROOM 1 ----------------------- n q^I { 8856 I 1670 rI 1670 I 4_ a 4'-7" 8'-6" I I I BEDROOM 1 I I I 856 1 3056 0+ Ac- F - - -- ---- --- L.-- -j 18080 8856 2'-2" 2'-11" 2'-10" 2'-11" 2'-2" 1'-8" 5'-8" V-8" 10"V-6" 3'-4" l'-6"10" 2'-6" 3'-0" 2'-6" 2'-8" 8'-8" 2'-8" 3'-6" 18'-0" 3'-6" 9'-0" 8'-0" 8'-0" 14'-0" Ile 25'-0" 80'-0" DIMENSION MAIN FLOOR PLAN SCALE: 1/4"=I' -O" GENERAL CONSTRUCTION NOTES -EXTERIOR WALLS 2X6 NOMINAL STUD FRAMING AT 16" O.C. BATT INSULATION TO REQUIRED 'R' VALUE BY LOCAL CODE • INTERIOR WALLS 2X4 NOMINAL STUD FRAMING AT 16" O.C. .PROVIDE ATTIC INSULATION AND VENTIUAT10N IN ACCORDANCE TO LOCAL CODE. • PROVIDE 12X12 ATTIC VENTS W/ INSECT SCREEN, TYPICAL •5/6" TYPE 'X' GYPSUM BOARD REQURED TO SEPARATE GARAGE FROM LIVING SPACES. • 20 MINUTE FIRE RATED DOOR REQUIRED FROM GARAGE TO HOUSE. • ALL FOOTING DEPTH TO BE DETERMINED BY LOCAL CODE WINDOWS & DOOR NOTES • ALL WINDOWS ARE INSULATED AND WEATHERSTRIPPED VERIFY CODE EGRESS WINDOW REQUIREMENTS PRIOR TO CONSTRUCTION •PROVIDE TEMPERED GLASS WHERE REQUIRED • VERIFY SILL HEIGHT ABOVE TUBS AND COUNTERS TO ACCOMMODATE TRIM AND BACKSPLASH • VERIFY WINDOW AND DOOR SIZES WITH CHOSEN MANUFACTURE PRIOR TO CONSTRUCTION. ADJUST AS NECESSARY. Reviewed for Code Compliance 44;6." *Building Inspector 00 W Q z �- LLI 0 0 (/) 0 W z 0 0 w Lij z —I _ P2 F= w C 1 < - o REV1910N: DRAWN BY: JCB NO: KDG CHECKED BY: DATE: M f?,16 PLOT DATE: 4-e:'^-15 DRAWING NO. 17J: u�NLE" Me 41 1dE: DFE (:f: 4 A#.9 Al.3 DIMENSION BASEMENT PLAN SCALE: 1/4"=V-0" OWNER AND BUILDER MUST CONSULT ENGINEER FOR LOCATION OF SHEAR WALLS. TIE DOWNS AND VERIFICATION OF LOAD BEARING WALLS, COLUMNS, FOOTINGS AND FOUNDATION SPECIFICATIONS. VERIFY FRAMING REQUIREMENTS. DESIGNER/DRAFTER IS NOT RESPONSIBLE FOR CONSTRUCTION, DESIGN OR ENGINEERING OF DRAWINGS SEAL DIJ �, JVORK HEAT TRAM S ON W H. ANCHOEs C.°,S W.H I� OVER 4 '-_- DRAWN BY: 'IGD NU: KQG CHECKED BY: 7L: a" 1r DRAWING NO. �l�i_ tS�{'c i i a1ti Pf 5iin , Al.4 OF U Z J c LLJ I W z W d _J m 0 t 0 Li w Z e U) CD Q 0 CL REVISION: DRAWN BY: 'IGD NU: KQG CHECKED BY: 7L: a" 1r DRAWING NO. �l�i_ tS�{'c i i a1ti Pf 5iin , Al.4 OF