Loading...
HomeMy WebLinkAboutREVIEWS (7-27-16) - 16-00454 - Madison Park Apartments ClubhouseMadison Park Apartments Clubhouse Building ReviewReview Date: 07/26/2016 Permit Number: 16-00454 Reviewed By: Quinton Owens Current Building Review Status: REVISIONS D ESCRIPTIO N CO MMEN TS STATUS Use classification is shown on plans as per IBC Section 302 Shown as B occupancy only, but also has assembly room large enough for more than 49 occupants (A occupancy). Will this be separated or non-separated mixed use? REVISIONS Incidental use meets the requirements of Table 508.2.5 1 hr fire separation between laundry room & rest of building shall extend to roof sheathing above (IBC 509.4.1 & 707.5. COMPLETED Fire barriers meet the requirements of IBC Section 707 Washer boxes are to be fire rated or outside of the rated wall. COMPLETED fireblocking and draftstopping meet the requirements of IBC Section 717. No details. It will be approved based on inspection. COMPLETED Automatic sprinklers are provided or exempted as per IBC Section 903.2 Not required.N/A Occupant load is identified on plans as per IBC Section 1004 Occupant load is not indicated on plans. Occupant load is to be posted near main exit or exit access door for the community room. REVISIONS Exits meet the requirements of IBC Sections 1020 and 1021 Add exit sign above door from community room to waiting room. COMPLETED An Energy Review is provided Please submit an updated energy report.REVISIONS Glass and Glazing meets the requirements of IBC Chapter 24 Windows by bathroom door & laundry room door are to be tempered (within 24" from a door). REVISIONS Madison Park Apartments Clubhouse Electrical ReviewReview Date: 06/29/2016 Permit Number: 16-00454 Reviewed By: Bret Stoddard Current Electrical Review Status: REVISIONS D ESCRIPTIO N CO MMEN TS STATUS Electrical: Service Electrical service calculations not in plans submitted-available fault current calculation and load calculation. Also nothing is noted for AIC rating of main equipment proposed. REVISIONS Electrical: Wiring Method No wiring method noted on plans.REVISIONS Electrical: Exit Signs/Emergency Lighting Reviewed for code compliance.COMPLETED Electrical: Energy Compliance Report Submitted Passes code as per report by 1% interior and 88% exterior. COMPLETED Madison Park Apartments Clubhouse Plumbing ReviewReview Date: 06/29/2016 Permit Number: 16-00454 Reviewed By: Don Allen Current Plumbing Review Status: REVISIONS D ESCRIPTIO N CO MMEN TS STATUS Meter Size/ Wye Strainer need to know the water meter size for the building REVISIONS Additional Inspector Comments: No gas line on the print. Madison Park Apartments Clubhouse HVAC ReviewReview Date: 06/29/2016 Permit Number: 16-00454 Reviewed By: Don Allen Current HVAC Review Status: REVISIONS D ESCRIPTIO N CO MMEN TS STATUS Meter Size/ Wye Strainer need to know the water meter size for the building REVISIONS Additional Inspector Comments: No gas line on the print. Madison Park Apartments Clubhouse Public Works Review - Site PlanReview Date: 07/07/2016 Permit Number: 16-00454 Reviewed By: Joel Gray Current Public Works Review - Site Plan Status: REVISIONS D ESCRIPTIO N CO MMEN TS STATUS Water Service only.N/A Sewer Service only.N/A Storm Storm water must be retained on-site.REVISIONS Storm Size of french drains for roof drains.REVISIONS Lighting No proposed site lighting. Lights for parking lot can not be building mounted. N/A Plans are approved for a footing/foundation ONLY permit? YES