Loading...
HomeMy WebLinkAboutFIRE SPRINKLER PRODUCT INFORMATION - 16-00577 - 117 S 2nd E - Mattson Apts - Bldg B NO 23 UnitsP.O. Box 3365 South EI Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 510 CPVC - COPPER - STEEL HANGER SIZE - SYSTEM PIPE: 3/4" thm 3" MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTING/APPROVAL - `®" 203 - EX 4231, EX 2551 FUNCTION - Support horizontal piping: 3/4" -3" CPVC. Support horizontal piping: 3/4"-2" Steel and Copper. Size 3/4" - 2" provides listed vertical/lateral restraint and prevents upward movement of pipe that supplies a pendent sprinkler below a ceiling. Stabilize vertical piping. INSTALLATION - Per these instructions including NFPA 13, 13R, 13D and CPVC manufacturers instructions. Install on horizontal or vertical mounting surface. FASTENERS - UL Listed per NFPA 13 in WOOD: 3/4" - 3" CPVC pipe - #905 screw - no pre -drill. 3/4" - 2" Steel and Copper pipe - 1/4"x 11/2" lag bolt - no pre -drill. in STEEL - min. 18 GA. 3/4" - 3" CPVC pipe - 1/4" or #14 Tek Screw. 3/4" - 2" Steel and Copper pipe - 1/4" or #14 Tek Screw. FEATURES • Offset edge eliminates abrasion. • Retainer dimples secure hanger to pipe during installation. • Required AFCON #905 screw included - 5/16" hex head. ORDERING - Part # and pipe size. CAN ALSO BE USED TO REPLACE - #500 Pipe Strap #520 Tin Strap SpeoifcAFCONpmducts are exclusively designed to be compatible ONLY with other AFCONproducts including parts and f orenee, rennin, in a listed sway brace, reseainer or hangerassembly. Be adobed thefollowingwarranty restrietioowill apply. DISCL VIER-AFCON tsill NOT wetrantagaimnhe filureofitspmducts whenusN wcontbioatioowith other products,panaorsysten¢ rut manufactured or sold by AFCON. AFCON shall NOT be liable under any cimumsmnoes wharmomr for any direct or indium, incidental or consequential damages ofany kind, including but not limited to loss ofbusinen, or profit when non-AFCONproduets have b«n, or are used. 1/12 P.O. Box 3365 South EI Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 514 CPVC- COPPER •STEEL OFFSET HANGER SIZE - SYSTEM PIPE: 3/4" thru 3" • MATERIAL - Carbon Steel. FINISH - Mil. Galvanized.. LISTING/APPROVAL - 1203 - EX 4231, EX 2551 PATENT - No. 6,648,278. FUNCTION - Support horizontal piping: 3/4" -3" CPVC or Copper. • Support horizontal piping: 3/4" - 2" Steel. Size 3/4" - 2" provides listed vertical/lateral restraint and prevents upward movement of pipe that supplies a pendent sprinkler below a ceiling. Stabilize vertical piping. INSTALLATION - Per these instructions including NFPA 13, 13R, 13D and CPVC manufacturers instructions. Listed Install on horizontal or vertical mounting surface. 3/4' Snap over pipe then squeeze strap back allowing pipe to slide freely. o- When #905 threads are exposed in wood, install #906 backing nut. FASTENERS - UL Listed per NFPA 13 WOOD - 3/4" - 3" CPVC pipe - #905 screw- no pre -drill. 3/4" - 2" Copper pipe - #905 screw- no pre -drill. 3/4" - 2" Steel pipe - 1/4"x1 1/2" lag screw - no pre -drill. Thru 5/8" gypsum board - 1/4" x T' lag screw. STEEL - min. 18 GA. - 3/4" - 3" CPVC pipe - 1/4" or #14 Tek Screw. 3/4" - 2" Copper pipe - 1/4" or 914 Tek Screw. 3/4" - 2" Steel pipe - 1/4" or #14 Tek Screw. CONCRETE: Required minimum load each fastener= 5(wt)+250lbs. 2 FEATURES * 1 1/2" Offset - loose fit allows pipe to slide. * 3/4" and I" pipe size made with common center -line. * Patented design for superior strength. * Offset edge eliminates abrasion. * AFCON#905 screw included - 5/16" hex head. ORDERING - Part # and pipe size. AFCON #906 backing nut sold separately. !0'01 Y o � t v �p� Listed Restraint 3/4" thru 2" SwificA£CONproducta an, exclonoaly designed to be compatible ONLY with otherAFCONpmduce, including pans W parteners, resulting in a listed sway brace, restrainer or banger assembly ae advhed the following warranty restriction will apply. DISCLAIMER- AFCOF will NOT warrant against Um failure of da producb when used in combination with other produc¢, pans or systems rmt manufactured or sold by AFCON. AFCONsball NOT be liable under any circumstances wh isaeuer for any direct or indirect, incidental oraonsequential damages ofany kind, including hot not IiniitM m loss of business orprofit, when nun-AFCONpmduces have bxn, or arc mM 10/08 P.O. Box 3365 South EI Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 511 CPVC - COPPER SIDE MOUNT HANGER SIZE - SYSTEM PIPE: 3/4" thru 2" MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTING/APPROVAL - 203 - EX 4231, EX 2551 FUNCTION - Support horizontal piping - CPVC or Copper. Stabilize vertical piping. INSTALLATION - Per these instructions including NFPA 13, 13R, 13D and CPVC manufacturers instructions. Install on vertical mounting surface. FASTENERS - UL Listed per NFPA 13. in WOOD: 3/4" - 2" CPVC pipe - #905 screw - no pre -drill. 3/4" - 2" Copper pipe - #905 screw - no pre -drill. in STEEL -min. 18 GA. 3/4" - 2" CPVC pipe - 1/4" or #14 Tek Screw. 3/4" - 2" Copper pipe - 1/4" or #14 Tek Screw. FEATURES * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. * RequiredAFCON#905 screw included - 5/16" hex head. ORDERING - Part # and pipe size. Side Yew - For Drawings Below Hanger -Wood Stud So! Hanger - Metal Stud SpmiacAFCONpmduccs are exclusively designed to be compatible ONLY with onerAFCON products including pans and fasteners, resulting in a listed sway brace, restrainer or banger assembly. He advised the following wamnty restriction will apply DISCLAIMER - AFCO.Y will NOT wamant against the failure ofils produce aeben used in oambinilian with other products, pelts or systems not manufactued or sold by AFCOR. AFCON shall NOT be liable under any circnmstances whntsoever for any dirmt or itMhmp incidental or consequential damages of any kind, including but not limited to loss oflo ssmeca or profit, when non-AFCONpmdurbs have been, or ere used. • i 9/08 tyco Fire Protection Products BLAZEMASTER CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet General Description TYCO CPVC Pipe and Fittings pro- duced by Tyco Fire Protection Prod- ucts (TFPP) are designed exclusively for use in wet pipe automatic fire sprinkler systems. The TYCO CPVC Pipe and Fittings are produced from BLAZEMASTER CPVC compound that is a specially developed thermo- plastic compound composed of post chlorinated polyvinyl chloride (CPVC) resin and state of the art additives. TYCO CPVC Pipe and Fittings are easier to install than traditional steel pipe systems, and at the same time, provide superior heat resistance and strength as compared to traditional CPVC and PVC piping materials used in the plumbing trade. Various adapt- ers are available to connect CPVC pipe to metallic piping. All female pipe thread adapters have brass inserts for durability. Grooved adapters connect directly to grooved end valves and metallic pipe, with flexible grooved end couplings. NOTICE The CPVC Pipe and Fittings produced with BLAZEMASTER CPVC compound described herein must be installed and maintained in compliance with this document and with the applicable standards of the National Fire Protec- tion Association (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Technical Data Sizes 3/4 Inch thru 3 Inch Maximum Working Pressure 175 psi Approvals UL and C -UL Listed FM Approved LPCB Approved NSF Certified MEA Approved City of Los Angeles (Refer to Installation Handbook IH -1900 dated June 2008 for exact listing/approval information.) Manufacture Source U.S.A. Material Pipe: ASTM F442, SDR 13.5 Fittings: ASTM F438 (Sch. 40) ASTM F439 (Sch. 80) ASTM F1970 Color Orange WorldwideI wwwtyco-fire.com Contacts Installation TYCO CPVC Pipe and Fittings are to be to be installed in accordance with Installation Handbook IH -1900 dated April 2016. Page 1 of 2 APRIL 2016 TFP1915 TFP1915 Page 2 of 2 Care and Limited Maintenance Warranty TYCO CPVC Pipe and Fittings are to be For warranty terms and conditions, visit maintained and serviced in accordance www.tyco-fire.com with this section. Before closing a fire protection system control valve for Inspection or main- tenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must first be obtained from the proper authorities and all person- nel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central station alarms. The owner is responsible for the inspec- tion, testing, and maintenance of their fire protection system and de -vices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any authority having juris- diction. Contact the Installing contrac- tor or product manufacturer with any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 1 Telephone +1-215-362-0700 Copyright 0 2016 Tyco Fire Products, I.P. All rights reserved. i-yG.� SLAZEMASTEA Is a trademark of The LODrizol Corporation, FireProtection Proeructs &D BACKFLOW DIRECT ADer%uger 8aclr8owPrerention ProductLfne 4�pS51Fj�O C UL US 17ademritersLaboratoryClassziffedRatingAFlow Q raciezisfics The Deringer 20, 30, 40 and 50 backflow prevention valves are Sizes: 2Y2", 3 ", 4 ", 6", 8" designed to prevent non-health/health hazard pollutants from Working Pressure: 10-175psi (0.7-12.1 bar) entering the potable water supply system caused by Temperature Range: 33°-1407 (I °-60°C) backpressure and/or backsiphonage conditions. Orientations: 40/50(X) 20130(H, V) DeriugerNodels Zoo t7amcBm / ANP) Newmiv Deriager4a/vf'asosizoatal Qpm) 379 757 1136 1514 1893 2271 2650 3028 30 26 a v m 22 N 18 14 N 10 d 6 207 193 179 165 151 138 124 110 96 83 69 55 (kPa) 0 100 200 300 400 500 600 700 800 - Rated Flow 16- 150% of Rated Rate of Flow (gpm) Qpm) 1136 2271 3407 4592 5678 6813 7949 9084 26 a Q 22 0 18 J 2 14 y 10 a 6 0®0 179 165 151 137 124 110 96 82 69 55 (Va) 0 300 600 900 1200 1500 1800 2100 2400 Rate of Flow(gpm) Backflow Direct, LLC • 3290 Monier Circle • Rancho Cordova • California • 95742 • United States of America Phone: 916-760-4524 Website: www.backflowdirect.com Deri ager zfl1, y % 8orisowAj (1pm) 1514 3028 4542 60:6 757; 9085 16 110 26 14„ 95 8 12 8 83 O18 - - _ 6°(2000x) 55 N 6 41 n 4 28 N 14 LL Q - faereasing i7ow (kPa) 0 400 800 1200 1600 2000 2400 Derin�ger�0�30 Pert,s'oal Rate of Flow(gpm) (1pm) 379 7.57 1136 1514 1893 2271 2650 3028 20 fN 16 y 0 12 J 8 LO0 m 4 a 0 138 124 110 96 83 69 55 41 28 14 (kPa) 757 1136 151.1 7893 2271 26507 3028 200 300 400 18 Rate of Flow (gpm) 124 - Rated Flow ♦ - 150% of Rated 4 (1p(11) 1514 14 ♦ 2 Y2' 3., 110 10- ---- 96 12 124 N N 8„ 83 10 110 8 J 69 96 n 126° .. 83 55 10 6 J N 4 69 41 28 Q. O 14 inaeasing N n Flow 41 (kPa) 0 100 200 300 400 500 600 700 800 28 Rated Flow ♦ - 150% of Rated Rate of Flow (gpm) (1pm) 1514 3028 4542 60:6 757; 9085 16 110 26 14„ 95 8 12 8 83 O18 - - _ 6°(2000x) 55 N 6 41 n 4 28 N 14 LL Q - faereasing i7ow (kPa) 0 400 800 1200 1600 2000 2400 Derin�ger�0�30 Pert,s'oal Rate of Flow(gpm) (1pm) 379 7.57 1136 1514 1893 2271 2650 3028 20 fN 16 y 0 12 J 8 LO0 m 4 a 0 138 124 110 96 83 69 55 41 28 14 (kPa) Backflow Direct, LLC • 3290 Monier Circle • Rancho Cordova • California • 95742 • United States of America Phone: 916-760-4524 Website: www.backflowdirect.com 0 100 200 300 400 500 600 700 800 Rate of Flow (gpm) - Rated Flow ♦ - 150% of Rated (1p(11) 1514 3028 4542 6056 7571 9085 18 124 N 16 8„ 110 8 14 96 n 126° .. 83 O 10 20x130x J 69 d 8 55 6 N n 4 41 28 L1 2 icreaslagFlow 14 (kPa) 0 400 800 1200 1600 2000 2400 Rate of Flow(gpm) Backflow Direct, LLC • 3290 Monier Circle • Rancho Cordova • California • 95742 • United States of America Phone: 916-760-4524 Website: www.backflowdirect.com FIRE CORPORATION DESCRIPTION AND OPERATION QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT • PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable stan- dards. It offers the additional feature of greatly increased safe- ty to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design requirements. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuat- ing assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is ab- sorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distrib- uted in an approved pattern depending upon the deflector style used. QUICK RESPONSE UPRIGHT CONVENTIONAL QUICK RESPONSE PENDENT VERTICAL SIDEWALL TECHNICAL DATA • See reverse side for Approvals and Specifications. • Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141 °C) �. • Water Working Pressure Rating - 175 psi (12 Bars) • Factory tested hydrostatically to 500 psi (34 Bars) • Maximum low temperature glass bulb rating is -67°F (-55°C) QUICK RESPONSE • Frame - bronze • Deflector - brass • Screw - brass HORIZONTAL LPCICE • Lodgement Wire -stainless steel • Bulb seat -copper SIDEWALL HORIZONTAL • Spring - nickel alloy • Seal - teflon SIDEWALL • Bulb - glass with alcohol based solution, 3mm size *SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING NOV 2016 GFS -100a (Formerly A-20) QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH' FINISHES 2.8 (40 metric) 1/2"NPT (15mm) 21/4" (5.7cm) STYLE 4.2 (60 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Factory Bronze 5.6 (80 metric) 1/2"NPT (15mm) 21/4" (5.7cm) Chrome White Polyester' 8.0 (115 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Black Polyester2.3 8.0 (115 metric) I 3/4"NPT (20mm) 27/16' (6.2cm) X NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'HORIZONTAL SIDEWALL IS 2 9/16". 'FINISHES AVAILABLE ON SPECIAL ORDER. 'AVAILABLE AS cULus LISTED COROSION RESISTANT WHEN SPECIFIED ON ORDER. APPROVALS 'SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS. §HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6' BELOW THE CEILING. oINSTALL IN ACCORDANCE TO BS5306 AND ANY OTHER RELATED DOCUMENTS. }PENDENT VERTICAL SIDEWALL cULus LISTED FOR V MIN. SPACING. TUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR V MIN. SPACING. OR ORDINARY HAZARD LH: LIGHT HAZARD •1/2" NPT ORDERING INFORMATION SIN K Globe agrees to repair or replace any of its own manufactured TEMPERATURE products found to be defective in material or workmanship for a • Thread Size • Temperature • Finishes desired period of one year from date of shipment. • Quantity - Wrenches - P/N 325390 (1/2"); NYC -DOB STYLE Terms and Conditions of Sale (Our Price List). HAZARD' cULus FM LPC CE FIRE SPRINKIER CORPORATION NOV 2016 PRINTED U.S.A. GFS -100a (Formerly A-20) MODEL FACTOR MEA 101.92-E GL2815 2.8 LH X X X X X X --- --- --- X GL4215 4.2 LH X X X X X X --- --- --- X UPRIGHT GL5615 5.6 LH/OH X X X X X X X X X X GL8115 8.0• LH/OH X X X X X X --- --- --- X GL8118 8.0 LH/OH X X X X X X X X X X GL2801 2.8 LH X X X X X X --- --- --- X GL4201 4.2 LH X X X X X X --- --- --- X PENDENT GL5601 5.6 LH/OH X X X X X X X X X X GL8101 8.0' LH/OH X X X X X X X --- - X GL8106 8.0 LH/OH X X X X X X X X X X VERTICAL GL5632 5.6 LH X X X X X X X --- --- --- SIDEWALL' GL8133 8.0 LH X X X X X X --- --- --- --- GL2826§ 2.8 LH X X X X X X --- --- --- X GL4226§ 4.2 LH X X X X X X --- --- - X HORIZONTAL GL5626§ 5.6 LH/OH X X X X X X X --- -- X SIDEWALL GL5627o 5.6 LH/OH X X X X X --- --- X X --- GL8127§ 8.0 LH/OH X X X X X X --- --- --- --- CONVENTIONAL GL5624 5.6 LH/OH X X X X X -- - X X --- (OLD STYLE) GL8125 8.0 LH/OH X X X X X --- - X X --- 'SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS. §HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6' BELOW THE CEILING. oINSTALL IN ACCORDANCE TO BS5306 AND ANY OTHER RELATED DOCUMENTS. }PENDENT VERTICAL SIDEWALL cULus LISTED FOR V MIN. SPACING. TUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR V MIN. SPACING. OR ORDINARY HAZARD LH: LIGHT HAZARD •1/2" NPT ORDERING INFORMATION GLOBE° PRODUCT WARRANTY SPECIFY Globe agrees to repair or replace any of its own manufactured • Quantity • Model Number • Style • Orifice products found to be defective in material or workmanship for a • Thread Size • Temperature • Finishes desired period of one year from date of shipment. • Quantity - Wrenches - P/N 325390 (1/2"); For specific details of our warranty please refer to Price List P/N 312366 (L.O.) Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-8464-84-5082FAX 989-846 0d)BE 1-800-248-0278 www.globesprinkler.com rxo FIRE SPRINKIER CORPORATION NOV 2016 PRINTED U.S.A. GFS -100a (Formerly A-20) DESCRIPTION AND OPERATION RESIDENTIAL AUTOMATIC SPRINKLERS MODELS GL4110 & GL4910 PENDENT RECESSED PENDENT The Globe Model GL4110 and GL4910 Residential Sprinklers have a low profile yet durable design which utilize a 3mm fran- gible glass ampule as the thermosensitive element. They feature economy, aesthetics and low flow. The combination of the 3mm frangible glass ampule and spe- cially designed deflector make the Model GL4110 and GL4910 Residential Sprinklers the ultimate in life safety and fire control. These Globe Pendent and Recessed Pendent Residential Sprin- klers have met the strict requirements of Underwriters Laboratories Inc. as described in the UL Standard for Residential Sprinklers for Fire Protection Service, UL 1626, and should be used accordingly. These sprinklers should also be installed in accordance with the appropriate NFPA Standard 13, 13D or 13R and under the direc- tion of the approving authorities having jurisdiction. The heart of Globe's Model GL4110 and GL4910 sprinklers proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pres- sure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distrib- uted in an approved pattern. The sprinkler and escutcheon are not factory assembled. Assembly is done in the field. TECHNICAL DATA •See reverse side for Approvals and Specifications. *Temperature Rating - 155°F (680C), 175°F (79°C) *Water Working Pressure Rating - 175 psi (12 Bars) •Factory tested hydrostatically to 500 psi (34 Bars) *Maximum low temperature glass bulb rating is -67°F (-55°C) • Frame - bronze • Deflector - brass • Screw - brass *Bulb seat - copper *Spring - nickel alloy • Seal - teflon • Bulb - glass with alcohol based solution, 3mm size • Escutcheon Assembly - steel RESIDENTIAL PENDENT GLOBE, ' �y�raawwwreq�y���_.. RESIDENTIAL RECESSED PENDENT -SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING MARCH 2015 A-1 BULLETIN GL4110/GL4910, REV. #9 RESIDENTIAL AUTOMATIC SPRINKLERS MODEL GL4110 & GL4910 PENDENT • RECESSED PENDENT SPECIFICATIONS AND APPROVALS SIN NOMINAL THREAD LENGTH FINISHES cULus NYC - DOB MODEL "K" FACTOR SIZE BETWEEN 155°F 17WF MEA 101.92-E GL4110 4.1 (58 metric) P.S.I. (bars) G.P.M. (Umin.) SPRINKLERS FEET(Meters) Factory Bronze PENDENT X X 12 (3.7) x 12 (3.7) 7.2 (.50) 11 (42) 1/2"NPT 21/2" Chrome X X GL4910 4.9 (68 metric) (15mm) (6.4cm) While Polyester'y X X 16 (4.9) x 16 (4.9) 11.1 (.77) 14 (53) X X Black Polyester'.' 7.0 (.48) 13 (49) NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'FINISHES AVAILABLE ON SPECIAL ORDER. 'AVAILABLE AS cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. INSTALLATION DATA FOR FLAT AND SLOPED CEILINGS** NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'WHEN THESE SPRINKLERS ARE USED IN NFPA 13 SYSTEMS, A0.1 DESIGN DENSITY MINIMUM SHALL BE UTILIZED. "REFER TO PAGE 2 OF GLOBE'S RESIDENTIAL SPRINKLER INSTALLATION GUIDE (BULLETIN R.S.I.G.) FOR NFPA 130 AND 13R REQUIREMENTS. 'FOR COVERAGE AREA DIMENSIONS LESS THAN OR BETWEEN THOSE INDICATED, USE THE MINIMUM REQUIRED FLOW FOR THE NEXT HIGHEST COVERAGE AREA FOR WHICH HYDRAULIC DESIGN CRITERIA ARE STATED. CROSS SECTION 1/2" ADJUSTMENT RECESSED PENDENT GdSE FIRE SPRINKLER CORPORATION MARCH 2015 ORDERING INFORMATION SPECIFY •Quantity • Model Number •Style .Orifice eTemperature.Finishes desired *Quantity - Wrenches - P/N 325390 *Quantity - Recessed Wrenches - P/N 325391 *Quantity - Protective Caps - P/N 327109 -CAP (Friction Fit Recessed) GLOBE'S PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List), PRINTED U.S.A. 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkler.com BULLETIN GL41I OIGL4910, REV. #9 TEMPERATURE MAX. AREA, MIN. DISTANCE SIN MODEL STYLE OF COVERAGE' MIN. MIN. PRESSUREFLOW BETWEEN 155°F 17WF (68°C) (79°C) LENGTH Z WIDTH Feet (Meters) P.S.I. (bars) G.P.M. (Umin.) SPRINKLERS FEET(Meters) PENDENT X X 12 (3.7) x 12 (3.7) 7.2 (.50) 11 (42) X -- 14 (4.3) x 14 (4.3) 8.8 (.59) 12 (45) GL4110 RECESSED 8(2.4) PENDENT X X 16 (4.9) x 16 (4.9) 11.1 (.77) 14 (53) X X 12 (3.7) x 12 (3.7) 7.0 (.48) 13 (49) X X 14 (4.3) x 14 (4.3) 8.2 (.57) 14 (53) PENDENT X X 16 (4.9) x 16 (4.9) 8.2 (.57) 14 (53) GL4910 RECESSED PENDENT X X 18 (5.5) x 18 (5.5) 12.0 (.83) 17 (64) X X 20(6.1)x20(6.1) 16.7(1.15) 20(76)1 NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'WHEN THESE SPRINKLERS ARE USED IN NFPA 13 SYSTEMS, A0.1 DESIGN DENSITY MINIMUM SHALL BE UTILIZED. "REFER TO PAGE 2 OF GLOBE'S RESIDENTIAL SPRINKLER INSTALLATION GUIDE (BULLETIN R.S.I.G.) FOR NFPA 130 AND 13R REQUIREMENTS. 'FOR COVERAGE AREA DIMENSIONS LESS THAN OR BETWEEN THOSE INDICATED, USE THE MINIMUM REQUIRED FLOW FOR THE NEXT HIGHEST COVERAGE AREA FOR WHICH HYDRAULIC DESIGN CRITERIA ARE STATED. CROSS SECTION 1/2" ADJUSTMENT RECESSED PENDENT GdSE FIRE SPRINKLER CORPORATION MARCH 2015 ORDERING INFORMATION SPECIFY •Quantity • Model Number •Style .Orifice eTemperature.Finishes desired *Quantity - Wrenches - P/N 325390 *Quantity - Recessed Wrenches - P/N 325391 *Quantity - Protective Caps - P/N 327109 -CAP (Friction Fit Recessed) GLOBE'S PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List), PRINTED U.S.A. 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkler.com BULLETIN GL41I OIGL4910, REV. #9 FIRE CORPORATION DESCRIPTION AND OPERATION QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES DRY TYPE HORIZONTAL SIDEWALL The Globe Quick Response GL Series Dry Type Horizontal Sidewall Sprinkler is designed for use in special applications such as freezing environments and conditions where sediment orforeign materials might accumulate in ordinary horizontal pipe nipples. The Globe Quick Response GL Series Dry Type Horizontal Sidewall Sprinkler utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. At the ampule's rated temperature, the sprinkler opens releasing the bulb seat, causing the inner tube assembly to move, allowing the spring assembly to pivot alongside the inner tube. At this time, water flows through the sprinkler and is distributed by the deflector, in an approved discharge pattern. It can be installed wherever standard spray sprinklers are specified but offers the additional feature of greatly increased safety to life. Quick Response Sprinklers should be used advisedly and under the direction of approv- ing authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern. TECHNICAL DATA • See reverse side for Approvals and Specifications. • Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C) 200°F (9YC), 286°F (141°C) • Water Working Pressure Rating - 175 psi (12 Bars) • Factory tested hydrostatically to 500 psi (34 Bars) • Maximum low temperature glass bulb rating is -67°F (-55°C) • Frame - bronze • Deflector - brass • Screw - brass • Bulb Seat - brass • Spring - nickel alloy • Seal - teflon • Retainer - brass • Pin - stainless steel SURFACE MOUNT SLEEVE & SKIRT RECESSED • Torsion Spring - stainless steel • Orifice Insert - brass EXTENDED • Bulb - glass with alcohol based solution, 3mm size • 3/4"NPT or 1"NPT • Outer Tube - galvanized steel pipe • Inner Tube -stainless steel NOTE: Globe's wrench P/N 337014 must be used to install this sprinkler. *SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER BULB COLOR N.F.P.A. MAXIMUM CEILING TEMPERATURES TEMPERATURE ORDINARY 135°F/155'F 57°C/68°C ORANGE/RED INTERMEDIATE 175°F/200°F 79°C/93`C`, YELLOW/GREEN HIGH 286°F 14 VC '." , BLUE DEC 2016 GFS -520a (Formerly A-58) QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES DRY TYPE HORIZONTAL SIDEWALL SPECIFICATIONS SIN MODEL NOMINAL THREAD LENGTH FINISHES "K' FACTOR SIZE GL5641 5.6 (80 metric) 1"NPT MIN. Factory Bronze GL5642 5.6 (80 metric) 314"NPT cLILus Variable to 48" Chrome 155°F FM Variable to 36" White Polyester2 GL8141 8.0 (115 metric) 1"NPT Black Polyester'A NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'FINISHES AVAILABLE ON SPECIAL ORDER. kULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. APPROVALS 18PRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPAI3 AND ANY OTHER RELATED DOCUMENTS. 'HORIZONTAL SIDEWALL STYLE - FM APPROVED 155-F (68°C), 200-F (93°C), AND 286•F (141°C) 'RECESSED HORIZONTAL SIDEWALL STYLE - FM APPROVED 155•F (68°C) AND 200-F (93°C) LH: LIGHT HAZARD: OH: ORDINARY HAZARD CROSS SECTIONS EXTENDED RECESSED SLEEVE & SKIRT SURFACE MOUNT GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). GL68E FIRE SPRINKLER CORPORATION DEC 2016 PRINTED U.S.A. IMPORTANT INSTALLATION DATA Globe GL Series Dry Pendent Sprinklers should be installed in accordance with the requirements set forth in NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible, the proper sprinkler head wrench may be used with extreme care for lengths up to approximately 18". Excessive force may distort the frame thus destroying the unit. When Installed in a wet system extending into a freezing area see chart on Dry Caution Sheet for minimum exposed barrel length to prevent ice plugs. Please refer to our Dry Caution Sheet for further important installation data. ORDERING INFORMATION SPECIFY • Quantity • Model Number • Style • Orifice • Temperature • Finishes desired • Quantity - Wrenches - PIN 333010 Quantity Recessed Wrenches - PIN 337014 Quantity - Protective Caps - PIN 327109 -cap (Faction Fit Recessed) Escutcheons Desired • "A" Dimension - Distance from face of fitting to the finished ceiling line regardless of escutcheon used. 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkler.com GFS -520a (Formerly A-58) DEFLECTOR MIN. SIN 135°F 155°F 1757 200°F 286°F TO CEILING STANCE BETWEEN STYLE MODEL HAZARD' (57°C) (68°C) (79°C) (93°C) (141°C) FM cULus DISTANCE Inches (mm) SPRINKLERS Feet (Meters) Horizontal GL5641 LH X X X X X X X Sidewall 4 (102) Recessed GL5642 LH X X X X X -- X to 6(l.8) Horizontal12 (305) Sidewall GL8141 I LH/OH X I X X X X --- X 18PRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPAI3 AND ANY OTHER RELATED DOCUMENTS. 'HORIZONTAL SIDEWALL STYLE - FM APPROVED 155-F (68°C), 200-F (93°C), AND 286•F (141°C) 'RECESSED HORIZONTAL SIDEWALL STYLE - FM APPROVED 155•F (68°C) AND 200-F (93°C) LH: LIGHT HAZARD: OH: ORDINARY HAZARD CROSS SECTIONS EXTENDED RECESSED SLEEVE & SKIRT SURFACE MOUNT GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). GL68E FIRE SPRINKLER CORPORATION DEC 2016 PRINTED U.S.A. IMPORTANT INSTALLATION DATA Globe GL Series Dry Pendent Sprinklers should be installed in accordance with the requirements set forth in NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible, the proper sprinkler head wrench may be used with extreme care for lengths up to approximately 18". Excessive force may distort the frame thus destroying the unit. When Installed in a wet system extending into a freezing area see chart on Dry Caution Sheet for minimum exposed barrel length to prevent ice plugs. Please refer to our Dry Caution Sheet for further important installation data. ORDERING INFORMATION SPECIFY • Quantity • Model Number • Style • Orifice • Temperature • Finishes desired • Quantity - Wrenches - PIN 333010 Quantity Recessed Wrenches - PIN 337014 Quantity - Protective Caps - PIN 327109 -cap (Faction Fit Recessed) Escutcheons Desired • "A" Dimension - Distance from face of fitting to the finished ceiling line regardless of escutcheon used. 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkler.com GFS -520a (Formerly A-58) Bulletin 135 Rev. M UO ® Model F1 l � � Residential Sprinklers for Design Density of .05 gpmfft2 Model F1 Res Sprinklers engineered for the lowest flows to meet the minimum design density of .05 gpm/ftz Types: 1. F1 Res 30 Pendent 2. F1 Res 30 Recessed Pendent/F2 3. F1 Res 30 Recessed Pendent/FP 4. F1 Res 49 Pendent 5. F1 Res 49 Recessed PendenVF1 6. F1 Res 49 Recessed PendenUFP 7. F1 Res 58 Pendent 8. F1 Res 58 Recessed PendenVF1 9. F1 Res 58 Recessed Pendent/FP 10. F1 Res 76 Pendent 11. F1 Res 76 Recessed PendenVF1 12. F1 Res 76 Recessed Pendent/FP 13. F1 Res 30 CCP Pendent 14. F1 Res 49 CCP Pendent 15. F1 Res 58 CCP Pendent 16. F1 Res 76 CCP Pendent 17. F1 Res 44 HSW 18. F1 Res 44 Recessed HSW/F2 19. Ft Res 58 HSW 20. F1 Res 58 HSWX 21. KRes58 HSWX 22. F1 Res 58 HSW Recessed HSW/F2 23. F1 Res 44 SWC Listings & Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) TW Ft Res 30, 49, 58 & 76 Recessed Pendent/F1 F1 Res 30, 49, 58 & 76 CCP Pendent Sprinklers for .10 Density: Refer to Bulletin 176 UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Patents US Patent No. 6,516,893 applies to the Model F1 Res 49 & 58 Pendent Sprinklers US Patent No. 7,353,882 applies to Model F1 Res 44 & 58 HSW Sprinklers US Patent No. 7,784,555 applies to Model F1 Res 44 SWC Sprinklers Product Description Model F1 Res Pendent sprinklers (Figs. 1, 2, 3, & 4) are fast response sprinklers combining excellent durability, high sensitiv- ity glass -bulb and low profile decorative design. The F1 Res F1 Res 30, 49, 58 &T6 Recessed Pendent/FP � ' P F1 Res 44 & 58 Recessed HSW/F2 F1 Res 44 Horizontal Sidewall sprinklers (Figs. 5, 6 & 7) are equally attrac- tive when above ceiling piping cannot be used. The 3mm glass -bulb pendent sprinklers permit the efficient use of residential water supplies for sprinkler coverage in residential fire protection design. The low flow F1 Res sprinklers are specially engineered for fast thermal response to meet the sensitive fire protection applica- tion needs of the latest residential market standards (UL 1626 Standard). Upon fire conditions, rising heat causes a sprinkler's heat -sensitive element, glass bulb or link to actuate, releasing the waterway for water flow onto the deflector, evenly distributing the discharged water to control a fire. Technical Data: • Thermal Sensor: Soldered Element (Link) or Nominal 3mm glass -bulb • Sprinkler Frame : Brass Casting • Sprinklers' Pressure Rating : 175 psi Factory Hydrostatically Tested to 500 psi • Thread Size: 1/2" NPT (R1/2) • K -Factor: 3.0 (43.2) (Actual) - F1 Res 30 Pendent Sprinkler 4.9 (70.6) (Actual) - F1 Res 49 Pendent Sprinkler 5.8 (83.5) (Actual)- Ft Res 58 Pendent & HSW Sprinkler 7.6 (109)(Actual) - F1 Res 76 Pendent Sprinkler 4.4 (63) (Actual) - F1 Res 44 HSW Sprinkler • Density: Minimum 0.05 gpm/ft2 Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application Model F1 Res Sprinklers are used for Residential Fire Pro- tection according to UL 1626 Standard*. For ceiling types: Smooth Flat Horizontal, or beamed, or sloped, in accordance with NFPA 13D, 13R, or 13 2013 editions. Be sure that orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of The Na- tional Fire Protection Association or the approving authority having jurisdiction. Installation Models F1 Res sprinklers are to be installed as shown. Model F1, F2 and FP Escutcheons, illustrated herewith, are Escutcheon*, F1 or F2, Data: the only recessed escutcheons to be used with Model 171 Res sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model F1 Res Pen- dent sprinklers use only the Model D sprinkler Wrench; for installing Models F1 Res Recessed Pendent, CCP & SWC sprinklers use only the Model GFR2 sprinkler wrench; for in- stalling Model Ft Res Recessed HSW sprinklers use only the Model GFR2 Sprinkler Wrench. Use of wrenches other than those specified may damage these sprinklers. Install F1 Res 44 with a ceiling to deflector distance of 4" - 12". Flow arrow on deflector must point away from near wall and "Top" mark- ing must face ceiling. Type Adjustment "A" o t to Face of fitting ceiling e Deflector Distance below bottom of beam Sprinkler Length Inch (mm) Inch (mm) Inch (g Inch mm F1 3/4(19,0) Min. Recessed = 15/a (41.3) /a (9.5) 13/4(44.4) '12" NPT R /z 2,/z4' (8.2) Max. Recessed =%3 22.2 11/,(28.6) 1 25.4 F2 '/,(12.7) Min. Recessed = 15/a (41.3) 3/,(9.5) 13/,(44.4) Max. Recessed =1'/e 28.6 '/,(22.2) 1'/a 31.7 ' Note: Escutcheons Fl or F2 may be used with Model F1 Res 49, 58 & 76 Recessed Pendent Sprinkler Model F1 Res 30, 49, 58 & 76 Pendent usr.°n Model F1 Res 30 Recessed Pendent / F2 58 & 76 Recessed Pendent / F1 Fig. 1 Fig. 2 Technical Data: F1 Res 30 Pendent and Recessed Pendent (SIN R3511) Thread Nominal Orifice Max. Pressure Sprinkler Temp. Ratin Max. Ambient Tem . Actual K Sprinkler Length °F °C °F °C Size Inch mm psi bar Factor Inch mm '12" NPT R /z 2,/z4' (8.2) 175 (12) 155 68 100 175 79 38 3.0 (43.2) 2.25(57) Max Ordinary Temp. Rating Intermediate Temp. Rating Minimum Max, Coverage area Spacing Pressure 76°F/7 Top of Dnf h (m ,Ceiling Spacing Ft x Ft (m x i Ft (m) Flow Pressure Flow Pressure Ft (m) GPM Umin PSI(bar).GPM Umin PSI bar 12 x 12 (3,6 x 3,6) 12(3,6) 8(30.3) 7.0 (0,48) 8 (30,3) (0,48) Smooth Ceilings 11/4 to 4(31.7 to 102) using F2 escutcheon. 14 x 14 (4,3 x 4,3) 14(4,3) 10(37,8) 11(0,76) 10 (37,8) ;7.0 (0,76) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 1'/4 to 13/416 8(2,4) x 16 (4,9 x 4,9) 16(4,9) 13(49) 18.8(1,3) 13 (49) .8 (1,3) 31.7 to 44.4 usina F2 escutcheon For Ceiling types refer to NFPA 13, 13R or 13D 2. Technical Data: F1 Res 49 Pendent and Recessed Pendent (SIN R3516) Thread Nominal Orifice Max. Sprinkler Max. Actual Sprinkler Size Inch (mm) Pressure Ten . Ratina Ambient Temp. K Length °F °C °F °C Pressure Fl x Fl (m x m) Ds! bar Factor Inch mm ''/2" NPT 7/16" (11) 175 (12) 155 68 100 38 4.9 (70.6) 2.25 (57) R''/z 12(3,6) 13 (49) 175 1 79 150 66 Smooth Ceilings 11/4 to 4 (31.7 to 102) using F2 escutcheon. For Ceiling types refer to NFPA 13, 13R or 13D Nominal Orifice Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector Minimum Max. Coverage area Max. Spacing 155°FMOC 175°F/790C to Ceiling Spacing Flow Pressure Flow Pressure Fl x Fl (m x m) Ft (m) Flow Pressure '/z" NPT 1/z" (13) GPM L/min PSI bar GPM L/min PSI bar Inch (mm) Ft (m) 12 x 12 (3,6 x 3,6) 12(3,6) 13 (49) 7.0 (0,48) 13 (49) 7.0 (0,48) Smooth Ceilings 11/4 to 4 (31.7 to 102) using F2 escutcheon. 14 x 14 (4,3 x 4,3) 14(4.3) 13 (49) 7.0 (0,48) 13 (49) 7.0 (0,48) 1 to 4 (25.4 to 102) using Fl escutcheon. 16(4,9) 16 x 16 (4,9 x 4,9) 16(4,9) 13 (49) 7.0 (0,48) 131 7.0 (0,48) Beamed Ceilings per NFPA 13D, 13R or 13 installed in 8(2,4) 18x 18(5,5x 5,5) 18(5,5) 18 x 18 (5,5 x 5,5) 18(5.5) 17 (64,3) 12 (0,83) 17 (64,3) 12 (0,83) beams 1'/4 to 13/4 (31.7 to 20 x 20 (6,1 x 6,1) 20(6.1) 44.4) using F2 escutcheon, 1 20.2 (1,4) 20 x 20(6,1 x6,1) 20(6,1) 20(75,7) 16.7(1,14) 20(75,7) 16,7(1,14) to 13/4(25.4 to 44.4) using Fl escutcheon For Ceiling types refer to NFPA 13, 13R or 13D Technical Data: F1 Res 58 Pendent and Recessed Pendent (SIN R3513) Thread Nominal Orifice Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector Minimum Max. Coveregearea Max. Spacing 155°11 175°F/79°C K Factor Length Ft x Ft (m x m) Ft (m) to Ceiling Spacing Flow Pressure Flow Pressure '/z" NPT 1/z" (13) GPM Wim PSI bar GPM L/min PSI bar Inch (mm) Ft 12 x 12 (3,6 x 3,6) 12(3,6) 15 (57) 9.4 (0,65) 15 (57) 9.4 (0,65) Smooth Ceilings 4 to 8 (100 to 203) using F2 escutcheon. 14 x 14 (4,3 x 4,3) 14(4,3) 16(60,S) 10.6 (0,73) 16 (60,5) 10.6 (0,73) 4 to 8 (100 to 203) using F1 escutcheon. 16 x 16 (4,9 x 4,9) 16(4,9) 17 (64,3) 12.0 (0,83) 17 (64,3) 12.0 (0,83) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 8(2,4) 18x 18(5,5x 5,5) 18(5,5) 19(72) 15.0(1,0) 19(72) 15.0(1,0) 4'/4 to 8(108 to 203) using F2 escutcheon, 4 to 8 (100 to 203) 20 x 20 (6,1 x 6,1) 20(6.1) 22 (83,2) 20.2 (1,4) 22 (83,2) 20.2(l.4) using F1 escutcheon Technical Data: F1 Res 58 Pendent and Recessed Pendent (SIN R3513) Thread Nominal Orifice Max. Sprinkler Max. Actual Sprinkler Size Inch (mm) Pressure Temp. RatinAmbient Temp. K Factor Length °F °C °F °C Pressure Ft x Ft (m x m) psi bar Inch mm '/z" NPT 1/z" (13) 175 (12) 155 68 100 38 5.8 (83.5) 2.25 (57) R''/z 12(3,6) 16 (61) 175 79 150 66 Smooth Ceilings 1'/4 to 4 (31.7 to 102) using F2 escutcheon. For Ceiling types refer to NFPA 13, 13R or 13D w Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector Minimum Max. Coverage area Max. Spacing 1550111 C 175°F/790C to Ceiling Spacing Flow Pressure Flow Pressure Ft x Ft (m x m) Ft (m) GPM L/min PSI bar GPM L/min PSI bar Inch (mm) R(m) 12 x 12 (3,6 x 3,6) 12(3,6) 16 (61) 7.6 (0,53) 16 (61) 7.6 (0,53) Smooth Ceilings 1'/4 to 4 (31.7 to 102) using F2 escutcheon. 14 x 14 (4,3 x 4,3) 14(4,3) 16 (61) 7.6 (0,53) 16 (61) 7.6 (0,53) 1 to 4 (25.4 to 102) using F1 escutcheon. 16 x 16 (4,9 x 4,9) 16(4,9) 16 (61) 7.6 (0,53) 16 (61) 7.6 (0,53) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 8(2.4) 18 x 18 (5,5 x 5,5) 18(5,5) 19 (72) 10.8 (0,75) 19 (72) 10.8 (0,75) 11/4 to 13/4 (31.7 to 44.4) using F2 escutcheon, 1 to 13/4 (25.4 to 20 x 20 (6,1 x 6,1) 20(6,1) 22 (83,3) 14.4 (1,0) 22 (83,3) 14.4 (1,0) 44.4) using F1 escutcheon For Ceiling types refer to NFPA 13, 13R or 13D w Technical Data: F1 Res 76 Pendent and Recessed Pendent (SIN R7618) Thread Nominal Orifice Max. Sprinkler Max. K Sprinkler [58.7,m] Size Inch (mm) Pressure Temp. Ratina Ambient Temp. Factor Length °F °C °F •C CEILING si bar "A" FP Position Inch mm 3/4" NPT x'/22" (13.5) 175 (12) 155 68 100 38 7.6 (109) 2.25 (57) R'/4 W 175 79 150 66 HEIGHT 'h (12.7) 3 5/16" OM. 6/i6 7.9 3/4 19) 135FG04E [84. Imm] Min. Recessed 16/,6 24 F1 RES 30, 49. 58 & 76 CCP PEND. 3 and Fig. 4 are not suitable for installation in ceilings which have positive pressure in the space above. Ordinary Temp. Rating Intermediate Temp. Rating Max. Coverage area Max. Spacing 1550F)WC 175°F/790C Top of Deflector to Ceiling Minimum Ft x Ft (m x m) Ft (m) Inch (mm) ming Flow Pressure Flow GPM Pressure GPM Umin PSI bar Umin PSI bar Ft (m) 12 x 12 (3,6 x 3,6) 12(3,6) 21 (79,5) 7.6 (0,53) 21 (79,5) 7.6 (0,53) Smooth Ceilings 41/4 to 8 (108 to 203) using F2 escutcheon. 14 x 14 (4,3 x 4,3) 14(4,3) 21 (79,5) 7.6 (0,53) 21 (79,5) 7.6 (0,53) 4 to 8 (100 to 203) using F1 escutcheon. 16 x 16 (4,9 x 4,9) 16(4,9) 21 (79,5) 7.6 (0,53) 21 (79,5) 7.6 (0,53) Beamed Ceilings per NFPA 13D, 13R or 13 installed in 8(2.4) 18 x 18 (5,5 x 5,5) 18(5.5) 21 (79,5) 7.6 (0,53) 21 (79,5) 7.6 (0,53) beams 4'/4 to 8 (108 to 203) us- ing F2 escutcheon, 4 to 8 (100 20 x 20 (6,1 x 6,1) 20(6.1) 23 (87,1) 9.2 (0,63) 23 (87,1) 9.2 (0,63) to 203) using F1 escutcheon For Ceiling types refer to NFPA 13, 13R or 13D Model F1 Res 30.49.58 & 76 CCP Pendent* * Not listed for corrosion resistance. Model F1 Res 30, 49, 58 & 76 Recessed Pendent/FP rr pusn-on/inreaa-on esculcneon 2 5/8" DIA. [66.7mm] 2 5/8° [56.7mm] DIA. 2 5/16' DIA. 2 5/16" DIA. HOLE IN CEILING [58.7,m] C P CUP r 1 2112" REDUCER CUP \I � II/ CEILING 1 1/2" [38. imm] MAX. "A" FP Position FACE OF FITTING 3 AA 1 "J D MENSION FAC F FTI MAX. FACE OF FITTING TO FACE OF CEILING A. "B" FP ADJUSTMENT DIMENSION F1 RES 49 PENDENT/FP W 1/2(12.7) 15/16 (24) COVER ADJUSTMENT HEIGHT 'h (12.7) 3 5/16" OM. 6/i6 7.9 3/4 19) 135FG04E [84. Imm] Min. Recessed 16/,6 24 F1 RES 30, 49. 58 & 76 CCP PEND. 3 and Fig. 4 are not suitable for installation in ceilings which have positive pressure in the space above. Model F1 Res 30, 49, 58 & 76 Recessed Pendent/FP rr pusn-on/inreaa-on esculcneon 2 5/8" DIA. [66.7mm] HOLE IN CEILING 4 2 5/16" DIA. [58.7mm] C P r i i" N 1/2" REDUCER \I � II/ CEILING L j 1 1/2" [38. imm] MAX. "A" FP Position FACE OF FITTING TO FACE OF CEILING of beam D MENSION 1/2" [I3mm] MAX. A. "B" FP ADJUSTMENT F1 RES 49 PENDENT/FP Fig. 3 Fig. 4 Note: The F1 Res 76 will use a 1"x Y4" reducer. CCP Cover Plate Data: FP Escutcheon Data: Deflector Distance below bottom Cover Adjustment CCP Height "A" FP Position Deflector Distance below bottom Inch (mm) Inch (mm) of beam Inch (" of beam Inch mm Inch mm 1/2(12.7) 15/16 (24) 1/2 (13) - 1 (25.4) Max. Recessed —,/,6(11) 'h (12.7) 6/i6 7.9 3/4 19) 1/2 (13) - 1 (25.4) Min. Recessed 16/,6 24 1 25.4) Note: Sprinklers shown in Fig. 3 and Fig. 4 are not suitable for installation in ceilings which have positive pressure in the space above. 4. Technical Data: F1 Res 30 CCP Pendent and Recessed Pendent/FP (SIN R351 1) Thread Nominal Max. CCP Assembly Max. K Sprinkler Size Orifice Pressure Temp. atin Ambient Temp. Factor Length °F °C °F °C GPM in) Inch mmpsi bar Ratin Inch (mm) 1/z" NPT (R 1/2) 21f64" (8.2) 175 (12) 135 57 100 38 3.0 (43.2) 2.25 (57) For Ceiling types refer to NFPA 13, 13R or 13D Technical Data: F1 Res 49 CCP Pendent and Recessed Pendent/FP (SIN 3516) Nominal Ordinary Temp. Rating CCP Max. Minimum Max. Coverage area Max. Spacing 155°F/68°C Top of Deflector to Ceiling Spacing g Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft Factor Length GPM in) PSI bar psi (bar) Ratin 12 x 12 (3,6 x 3,6) Inch (mm) OF °C OF °C Smooth Ceilings "1/2 to 1 (13 to 25.4) using CCP. 12 x 12 (3,6 x 3,6) 12(3,6) 8(30.3) 7.0 (0,48) 1/2 to 1 (13 to 25.4) using FP escutcheon. 175 (12) 135 57 100 38 4.9 (70.6) 2.25 (57) Beamed Ceilings per NFPA 13D, 13R or 13 installed in 8(2,4) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 112 to 1 (13 to 25.4) using CCP. 8(2,4) 16 x 16 (4,9 x 4,9) 16(4,9) 14 x 14 {4,3 x 4,3) 14(4,3) 1 i (37,8) 13.4 (0,92) beams 1/2 to 1 (13 to 25.4) using CCP. 10.8 (0,75) %z to 1 (13 to 25.4) using FP escutcheon. 18 x 18 (5,5 x 5,5) 18(5,5) 1/210 1 (13 to 25.4) using FP escutcheon. 13.5 (0,93) For Ceiling types refer to NFPA 13, 13R or 13D Technical Data: F1 Res 49 CCP Pendent and Recessed Pendent/FP (SIN 3516) For Ceiling types refer to NFPA 13, 13R or 13D Technical Data: F1 Res 58 CCP Pendent and Recessed Pendent/FP (SIN R3513) Nominal Max. CCP Assembly Max, Sprinkler Thread Orifice Pressure Temp. RatingAmbient Tem K Length Size Inch mm psi bar OF °C OF °C Factor Inch mm '/2" NPT '12' (13) 175 (12) 135 57 100 38 5 8 (83.5) 2.25 (57) R'/2) Max. Coverage Nominal Ordinary Temp. Rating CCP Max. Minimum Max. Coverage Thread Orifice Max. Assembly Ambient K Sprinkler Size Inch Pressure Temp. Temp. Factor Length GPM Vmin (mm) psi (bar) Ratin 12 x 12 (3,6 x 3,6) Inch (mm) OF °C OF °C Smooth Ceilings 1/2 to 1 (13 to 25.4) using 14 x 14 (4,3 x 4,3) 14(4,3) 16 (61) %z" NPT (R/2) 'lie" (11) 175 (12) 135 57 100 38 4.9 (70.6) 2.25 (57) For Ceiling types refer to NFPA 13, 13R or 13D Technical Data: F1 Res 58 CCP Pendent and Recessed Pendent/FP (SIN R3513) Nominal Max. CCP Assembly Max, Sprinkler Thread Orifice Pressure Temp. RatingAmbient Tem K Length Size Inch mm psi bar OF °C OF °C Factor Inch mm '/2" NPT '12' (13) 175 (12) 135 57 100 38 5 8 (83.5) 2.25 (57) R'/2) Max. Coverage Ordinary Temp. Rating Minimum Max. Coverage Max. Spacing 155°F/68°C Top of Deflector to Ceiling Minimum area Ft (n1) Inch (mm) Spacing Flow Pressure Ft x Ft (m x m) GPM Vmin PSI bar Ft (m) 12 x 12 (3,6 x 3,6) 12(3,6) 13 (49) 7.0 (0,48) Smooth Ceilings 1/2 to 1 (13 to 25.4) using 14 x 14 (4,3 x 4,3) 14(4,3) 16 (61) 7.6 (0,53) 14 x 14 (4,3 x 4,3) 14(4,3) 13 (49) 7.0 (0,48) CCP. '/2 to 1 (13 to 25.4) using FP escutcheon. 16(4,9) 16 (61) 7.6 (0,53) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 112 to 1 (13 to 25.4) using CCP. 8(2,4) 16 x 16 (4,9 x 4,9) 16(4,9) 14 (53) 8-20.66) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 112 to 1 (13 to 25.4) using 8(2,4) 19 (72) 10.8 (0,75) %z to 1 (13 to 25.4) using FP escutcheon. 18 x 18 (5,5 x 5,5) 18(5,5) 18 (68,1) 13.5 (0,93) CCP. 112 to 1 (13 to 25.4) using FP escutcheon. 20x20(6,1x6,1) 1 20(6,1) 20(75,7) 16.7(1,14) For Ceiling types refer to NFPA 13, 13R or 13D Technical Data: F1 Res 58 CCP Pendent and Recessed Pendent/FP (SIN R3513) Nominal Max. CCP Assembly Max, Sprinkler Thread Orifice Pressure Temp. RatingAmbient Tem K Length Size Inch mm psi bar OF °C OF °C Factor Inch mm '/2" NPT '12' (13) 175 (12) 135 57 100 38 5 8 (83.5) 2.25 (57) R'/2) Max. Coverage Ordinary Temp. Rating Minimum areat Max. Spacing (1550 80C) Top of Deflector to Ceiling Spacing Flow Pressure Ft x (m x m) Ft (m) Inch (mm) GPM Umin PSI bar 12 x 12 (3,6 x 3,6) 12(3,6) 16 (61) 7.6 (0,53) Smooth Ceilings 1/2 to 1 (13 to 25.4) using CCP. %z to 1 (13 to 25.4) using FP escutcheon. 14 x 14 (4,3 x 4,3) 14(4,3) 16 (61) 7.6 (0,53) 16 x 16 (4,9 x 4,9) 16(4,9) 16 (61) 7.6 (0,53) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 112 to 1 (13 to 25.4) using CCP. 8(2,4) 18 x 18 (5,5 x 5,5) 18(5,5) 19 (72) 10.8 (0,75) %z to 1 (13 to 25.4) using FP escutcheon. 20x20(6,1x6,1) 20(6,1) 22(83,3) 14.4(1,0) For Ceiling types refer to NFPA 13, 13R or 13D H Technical Data: F1 Res 76 CCP Pendent and Recessed Pendent/FP (SIN R7618) Thread Nominal Max. CCP Assembly Max. K Sprinkler Thread Size Orifice Pressure Mo. atin Ambient Temp. Factor Length S-2n:mj OF °C OF °C Factor Inch mm psi (bar) Inch (mm) Inch (mm) 3/+1" NPT (RIM 17/32' (13.5) 175 (12) 135 57 100 150 38 66 7.6(109) 2.25 (57) 155 175 68 100 79 150 38 66 4.4(63) 2.45 (62) Max. Coverage Ordinary Temp. Rating Minimum Max. Spacing 155'F/68°C Top of Deflector to Ceiling area Ft x Ft (m x m} Ft (m) Inch (mm) Spacing (m) Flow Pressure GPM Vmin PSI(bar)Ft 12 x 12 (3,6 x 3,6) 12(3,6) 21 (79,5) 7.6 (0,53) Smooth Ceilings 1/2 to 1 (13 to 25.4) using CCP. 112 to 1 (13 to 25.4) using FP escutcheon. 14 x 14 (4,3 x 4,3) 14(4,3) 21 (79,5) 7.6 (0,53) 16 x 16 (4,9 x 4,9) 16(4,9) 21 (79,5) 7.6 (0,53) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 1/2 to 1 (13 to 25.4) using CCP. 8(2,4) 18 x 18 (5,5 x 5,5) 18(5.5) 22 (83,3) 8.4 (0,58) 1/210 1 (13 to 25.4) using FP escutcheon, 20 x 20 (6,1 x 6, 1) 20(6,1) 25(94,6) 10.8(0,74) For Ceiling types refer to NFPA 13, 13R or 13D fACF Fr f11Ti1W 7C7 .... WALL P'VENOON .. NOLE OM (57-2o-1 1 1"!2" NE£UCE:? 4 rm c7 T ;PN C+JL LA,, ;rout FiGH.T 'ICA 'NST �SP,StrofiL€R DYNE^;CH 0 055 ,-rrca�-n F1 RES 58 & 44 HSW/F2 Fig. 5 Technical Data: F1 Res 44 HSW & HSW/F2 (SIN R3531) • Model F1 Res 44 & 58 HSW • Model F1 Res 44 & 58 Recessed HSW/F2 Max. Thread Nominal Max. Sprinkler Ambient K Sprinkler �.I E, S-2n:mj Pressure Temp. Rating Temp. Factor Length Inch (mm) psi (bar)— inch (mm) i C F C " NPT316„ (R 1/2) F1 RES 58 & 44 HSW/F2 Fig. 5 Technical Data: F1 Res 44 HSW & HSW/F2 (SIN R3531) • Model F1 Res 44 & 58 HSW • Model F1 Res 44 & 58 Recessed HSW/F2 1 F2 escutcheon, 1/2" (13mm) adjustment Escutcheon, F2, Data: T Adjustment Facto f Fiitting Type Inch (mm) Inch (mm) F2 112 (13) 3116. 11'16 (47-17.4) Max. Thread Nominal Max. Sprinkler Ambient K Sprinkler Size Orifice Pressure Temp. Rating Temp. Factor Length Inch (mm) psi (bar)— inch (mm) F —F— C F C " NPT316„ (R 1/2) (10) 175 (12) 155 175 68 100 79 150 38 66 4.4(63) 2.45 (62) 1 F2 escutcheon, 1/2" (13mm) adjustment Escutcheon, F2, Data: T Adjustment Facto f Fiitting Type Inch (mm) Inch (mm) F2 112 (13) 3116. 11'16 (47-17.4) Max. Coverage area Ft x Ft (m x m) Max. Spacing155-F/68°G Ft (m) Ordinary Temp. Rating Intermediate Temp. Rating 175°F/79°C Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m) Flow GPM (Umin) Pressure PSI bar Flow GPM Umin Pressure PSI bar 12 x 12 (3,6 x 3,6) 12 (3,6) 12 (45,4) 7.5 (0,52) 12 (45,4) 7.5 (0,52) 4 to 6 (100 to 152); 1/2 (13) recessed using F2 escutcheon 8(2,4) 14 x 14 (4,3 x 4,3) 14(4,3) 14 (53,0) 10.2 (0,71) 14 (53,0) 10.2 (0,71) 16 x 16 (4,9 x 4,9) 16(4,9) 16 (60,6) 13.3 (0,92) 16 (60,6) 13,3(0,92) 16 x 18 (4,9 x 5,5) 16(4,9) 18 (68,1) 16.8 (1,16) 18 (68,1) 16.8 (1,16) 18 x 18 (5,5 x 5,5) 18(5.5) 19 (72,0) 18.7 (1,29) 19 (72,0) 18.7 (1,29) 16 x 20 (4,9 x 6,1) 16(4.9) 23 (87,1) 27.4 (1,89) 23 (87,1) 27.4 (1„89) 12 x 12 (3,6 x 3,6) 12(3.6) 14 (53,0) 10.2 (0,71) 14 (53,0) 10.2 (0,71) 6 to 12 (152 to 305); 1/2 (13) recessed using F2 escutcheon %2 (13) recessed using F2 escutcheon 14 x 14 (4,3 x 4,3) 14(4.3) 16 (60,6) 13.3 (0,92) 16 (60,6) 13.3 (0,92) 16 x 16 (4,9 x 4,9) 16(4,9) 17 (64,4) 15.0 (1,04) 17 (64,4) 15.0 (1 „04) 16 x 18 (4,9 x 5,5) 16(4,9) 20 (75,7) 20.7 (1,43) 20 (75,7) 20.7 (1,43) 16 x 20 (4,9 x 6,1) 16(4,9) 23 (87,1) 27.4 (1,89) 23 (87,1) 27.4 (1,89) For Ceiling types refer to NFPA 13, 13R or 13D Technical Data: Mes 58 HSW & HSW7F2TSIN 83533) Escutcheon, F2, Data: Adjustment Factawof all Type Inch (mm) o wll Inch (mm) F2 '/,(13) 3/1e _iris (4.7. 17.4) Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector to Minimum Max. Coverage area Max. Spacing 155°F/68°C 175°FC79°C Ceiling Spacing m Ft x Ft (m x m) Ft (m) Flow Pressure Flow Pressure Inch ling(mmFt (in GPM V i PSI b GPM V' PSI b 12 x 12 (3,6 x 3,6) Nominal Max. Max. Sprinkler mrn 16 (60,6) Sprinkler Thread Orifice Pressure Ambient Temp. Rating K Length Size Inch 16 x 16 (4,9 x 4,9) Temp. Factor Inch 21 (79,5) mm Psi (bac) 16 x 18 (4,9 x 5,5) mm 'F °C °F °C %z" NPT '/2" (13) 175 (12) 155 68 100 38 5.8 (83.5) 2.45 (62) R''/2 12 x 12 (3,6 x 3,6) 12 (3,6) 175 79 150 66 14.4 (1,0) Adjustment Factawof all Type Inch (mm) o wll Inch (mm) F2 '/,(13) 3/1e _iris (4.7. 17.4) Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector to Minimum Max. Coverage area Max. Spacing 155°F/68°C 175°FC79°C Ceiling Spacing m Ft x Ft (m x m) Ft (m) Flow Pressure Flow Pressure Inch ling(mmFt (in GPM V i PSI b GPM V' PSI b 12 x 12 (3,6 x 3,6) 12(3,6) n 16 (60,6) ar 7.6 (0,53) mrn 16 (60,6) ar 7.6 (0,53) 14 x 14 (4,3 x 4,3) 14(4,3) 18 (68,2) 9.7 (0,69) 18 (68,2) 9.7 (0,69) 16 x 16 (4,9 x 4,9) 16(4,9) 21 (79,5) 13.2 (0,91) 21 (79,5) 13.2 (0,91) 4 to 6 (100 to 152); 1/2 (13) recessed 16 x 18 (4,9 x 5,5) 16(4,9) 25 (94,7) 18.6 (1,28) 25 (94,7) 18.6 (1,28) using F2 escutcheon 16 x 20 (4,9 x 6,1) 16(4.9) 29 (109,8) 25.0 (1,73) 29 (109,8) 25.0 (1,73) 12 x 12 (3,6 x 3,6) 12 (3,6) 22 (83,3) 14.4 (1 10) 22 (83,3) 14.4 (1,0) 14 x 14 (4,3 x 4,3) 14(4.3) 22 (83,3) 14.4 (1,0) 22(83,3) 14.4 (1,0) 6 to 12 (152 to 305); 16 x 16 (4,9 x 4,9) 16(4,9) 26 (98,4) 20.1 (1,39) 26 (98,4) 20.1 (1,39) %2 (13) recessed using F2 escutcheon 16 x 18 (4,9 x 5,5) 16(4,9) 31 (117,4) 28.6 (1,97) 31 (117,4) 28.6 (1,97) Ceiling types refer to NFPA 13, 13R or 13D N 8(2,4) Model F1 Res 44 SWC* " Not listed for corrosion resistance. Y, N- 4 d 5 ] T FN CGLL4.9 IINRL nCYT 4L�If."T iFR1MF'LTn Tar_hniral rata- FiRPc 44 SWr (GIN PIR111 Max. Spacing Ft (m) Ordinary Temp. Rating 1355°F/68°C Cover 14 Flow GPM L/min Pressure PSI bar t Nominal Max. Temp, Ambient " Not listed for corrosion resistance. Y, N- 4 d 5 ] T FN CGLL4.9 IINRL nCYT 4L�If."T iFR1MF'LTn Tar_hniral rata- FiRPc 44 SWr (GIN PIR111 f1 _1 (C1 n%mnv] - r.'.' • � , +. Damm] F -I- RES ._44_ SWC Fig. 6 Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating 1355°F/68°C Cover Max. Flow GPM L/min Pressure PSI bar Thread Nominal Max. Temp, Ambient K Sprinkler Size Orifice Pressure Ratin Temp Factor Length 16 x 18 (4,9 x 5,5) Inch (mm) psi (bar) 18.7 (1,13) Inch (mm) of °C OF °C %2" NPT R'/2) 1/81,00) 175 (12) 135 57 100 38 4.4(63) 2.45 (62) f1 _1 (C1 n%mnv] - r.'.' • � , +. Damm] F -I- RES ._44_ SWC Fig. 6 Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating 1355°F/68°C Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m) Flow GPM L/min Pressure PSI bar 12 x 12 (3,6 x 3,6) 12(3,6) 13 (49,2) 8.7 (0,60) 410 6 (100 to 152); 1/2 (13) recessed using F2 escutcheon 8(2,4) 14 x 14 (4,3 x 4,3) 14(4,3) 14 (53,0) 10.2 (0,71) 16 x 16 (4,9 x 4,9) 16(4,9) 17 (64,3) 15.0 (1,1) 16 x 18 (4,9 x 5,5) 16(4.9) 19 (71,8) 18.7 (1,13) 16 x 20 (4,9 x 6,1) 16 (4,9)' 23 (87,1) 27.4(l.89) 12 x 12 (3,6 x 3,6) 12(3.6) 14 (52,9) 10.2 (0,71) 6 to 12 (152 to 305); '/2 (13) recessed using F2 escutcheon 14 x 14 (4,3 x 4,3) 14(4,3) 15 (56,7) 11.7 (0,81) 16 x 16 (4,9 x 4,9) 16(4.9) 18 (68,1) 16.8 (1,16) 18 x 18 (4,9 x 5,5) 16(4.9) 20 (75,6) 20.7(l.43) For Ceiling types refer to NFPA 13, 13R or 13D NO Technical Data: F1 Res 58 HSWX (SIN RA3533) Max. Coverage area Ft x Ft (m x m) Thread Nominal Max. Sprinkler Max. Ambient K Sprinkler Sprinkler Pressure PS!(bar)Inch Size Orifice Pressure Temp. Rating Temp. Factor Length Identification 20 x20(6,1 x6, 1) 20(6,1) Inch (mm) psi (bar) 30(114) Inch (mm) Number (SW) 'F oC OF ,C Bulb %2" NPT (R%2) 112" (13) 175 (12) 155 175 68 79 100 150 38 66 5.8 (83.5) 2.45 (62) RA3533 Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating 155°F/Fr8°C Intermediate Temp. Rating 175OF/79°C Top of Deflector to Ceiling (mm) Minimum Spacing Ft (m) Flow GPM in) Pressure PSI bar Flow GPM Vmin Pressure PS!(bar)Inch 18 x 20 (5,5 x 6,1) 18(5.5) 30 (114) 26.8 (1,85) 30 (114) 26.8 (1,85) 4 to 6 (100 to 152); 1/2 (13) recessed using F2 escutcheon 8(2.4) 20 x20(6,1 x6, 1) 20(6,1) 30(114) 26.8(1,85) 30(114) 26.8(1,85) 16 x 22 (4,9 x 6,7) 16(4.9) 33 (125) 32.4 (2,23) 33 (125) 32.4 (2,23) 16 x 24 (4,9 x 7,3) 16(4,9) 38 (144) 42.9 (2,96) 38 (144) 42.9 (2,96) 14 x 26 (4,3 x 7,9) 14(4,3) 42 (160) 52.4 (3,75) 42 (160) 52.4 (3,75) 18 x 20 (5,5 x 6,1) 18(5,5) 35 (133) 36.4 (2,5) 35 (133) 36.4 (2,5) 6 to 12 (152 to 305); 1/2 (13) recessed using F2 escutcheon 16 x 22 (4,9 x 6,7) 16(4.9) 38 (144) 42.9 (2,96) 38 (144) 42.9 (2,96) 16 x 24 (4,9 x 7,3) 16(4.9) 42(1 0) 52.4 (3,6) 42 (160) 52.4 (3,6) 14 x 26 (4,3 x 7,9) 14(4,3) 46 (174) 62.9 (4,34) 46 (174) 62.9 (4,34) For Ceiling types refer to NFPA 13, 13R or 13D FACE OF RTTING TO WALL DIMENSION 1 11/16" MIN. 1.8mm] 2 1%4" HOLE DIA. , (57.2mm] 1CEILING TO 2m j3A j3.2mm] DEFLECTOR I - X r/2" REDUCER ----7 DIMENSION r 15/16" DIA. 1.11 ' I 49.2mm — j 2 27/32" DIA. [72.2mm] T!/RN COLLAR UNTIL �1 TIGHT AGAINST SPRINKLER\'+ WRENCH BOSS. �3sFcoe 1/2" (1.3mm] ADJUSTMENT F1 RLS 58 HSWX Fig. 7 0 • Model F1 Res 58 HSWX (Bulb) • Model KRes58 HSWX (Link) Technical Data; KRes58 HSWX (RA3593) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Nominal Max. Max. Flow GPM Vmin Sprinkler Sprinkler 18(5,5) Thread Orifice Pressure Ambient K Length Identification 26.8(1,85) Size Inch (mm) psi (bar) 32.4 (2,23) Factor Inch (mm) Number (SIN) oFem ac 14(4.3) 42 (160) 52.4 (3,75) 18 x 20 (5,5 x 6,1) 18(5.5) 35 (133) 36.4 (2,5) Link 1/2° NPT (R/2) 112" (13) 175 (12) 100 38 5.8 (83.5) 2.45 (62) RA3593 Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating 166°Fll4°c Top of Deflector to Ceilingling Inch Minimum Spa cin g Ft cin Flow GPM Vmin Pressure PSI bar 18 x 20 (5,5 x 6, 1) 18(5,5) 29(109) 25(1,72) 4 to 6 (100 to 152); '/2 (13) recessed using F2 escutcheon 8(2.4) 20x20(6,1 x6,1) 20(6,1) 30(114) 26.8(1,85) 16 x 22 (4,9 x 7,3) 16(4,9) 33 (125) 32.4 (2,23) 16 x 24 (4,9 x 7,3) 16(4.9) 38 (144) 42.9 (2,96) 14 x 26 (4,3 x 7,9) 14(4.3) 42 (160) 52.4 (3,75) 18 x 20 (5,5 x 6,1) 18(5.5) 35 (133) 36.4 (2,5) 6 to 12 (152 to 305); '/2 (13) Recessed using F2 escutcheon 16 x 22 (4,9 x 6,7) 16(4,9) 38 (144) 42.9 (2,96) 16 x 24 (4,9 x 7,3) 16(4.9) 42 (160) 52.4 (3,6) 14 x 26 (4,3 x 7,9) 14(4,3) 46 (174) 62.9 (4,34) For Ceiling types refer to NFPA 13, 13R or 13D Maintenance Model F1 Res 30, 49, F1 Res 58, F1 Res 76 and F1 Res 44 Sprinklers should be inspected and the sprinkler sys- tem maintained in accordance with NFPA 25, 13, 13D, and 13R. Do not clean sprinkler with soap and water, Am- monia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non -operation. Model F1 Res 30, 49 & 58 Pendent Sprinkler Specifications Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential pendent sprin- klers engineered to provide a minimum design density of 0.05 gpm/ft' over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guide- lines and the applicable installation standard. Deflector - to -ceiling distance listing shall be 1" to 8" maximum, only for F1 Res 49. Sprinkler frame and deflector shall be of bronze frame construction having a'/2" NPT thread. Wa- ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with top -loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (680C)] [175°F (791C)]. Sprinklers shall have a nominal K -factor of 3.0, 4.9 and 5.8. Standard finish: [Bronze] [Chrome - plated] [White Polyester] [Special finish- specify]. Resi- dential pendent sprinklers shall be Reliable Model F1 Res 30, 49 & 58, SIN R3511, R3516 & R3513 (Bulletin 135). Model F1 Res 49 & 58 Recessed Pendent/F1, Model F1 Res 30, 49 & 58 Recessed Pendent/ F2, Model F1 Res 30,49 & 58 Recessed Pendent/ FP Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential recessed pen- dent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's in- stallation guidelines and the applicable installation stan- dard. Deflector -to -ceiling distance listing shall be 1" to 8" maximum, only for F1 Res 49. Sprinkler frame and deflec- tor shall be of bronze frame construction having a'/2" NPT thread. Water seal assembly shall consist of a Teflon" coated Belleville spring washer with top -loaded extruded "DuPont Registered Trademark 10. or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)j [175°F (790C)]. Sprinklers shall have a nomi- nal K -factor of 3.0, 4.9 & 5.8. Standard finish: [Bronze] [Chrome -plated] [White Polyester] [Special finish- spec- ify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with '/z" adjustment (Model F2)] [with 3/4" adjustment (Model F1)] [of push -on and thread off design with 112" adjustment (Model FP)]. Standard fin- ish shall be [brass][bright chrome] [white painted]. Resi- dential recessed pendent sprinklers shall be Reliable [Model F1 Res 30, 49 & 58 Recessed Pendent/F1 ] [Model F1 Res 30, 49 & 58 Recessed Pendent/F2] [Model F1 Res 30, 49 & 58 Recessed Pendent/FP] SIN 83511, R3516 & R3513 (Bulletin 135). Model F1 Res 30, 49 & 58 CCR Pendent (Concealed) Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential concealed sprinklers engineered to provide a minimum design den- sity of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be in- stalled in conformance with the manufacturer's installa- tion guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a '/z" NPT thread. Water seal as- sembly shall consist of a Teflon* coated Belleville spring washer with top -loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155°F (680C). Cover plate assem- bly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push -on and thread -off design allowing a'/z" cover plate adjustment. Cover plate tem- perature rating shall be 135°F (570C). A plastic protec- tive cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color- specify]. ]. Concealed pendent sprinklers shall be Reliable Model F1 Res 30, 49 & 58 CGP, SIN R3511, R3516 & R3513 (Bulletin 135). Model F1 Res 44, F1 Res 58 Horizontal Sidewall, F1 Res 58 HSWX & KRes58 HSWX Residential Sprinkler Specifications Sprinklers shall be [cULus Listed] low flow residential horizontal sidowall sprinklers engineered to provide a minimum design density of 0.05 gprn/ft2 over the listed coverage area. Listed flows as specified by the manu- facturer's technical data sheets are to be used. Residen- tial sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a'/21° NPT thread. Water seal assembly shall consist of a Teflon* coated Bel - *DuPont Registered Trademark leville spring washer with top -loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155QF (680C)] [175°F (79°C)]. The solder element (Link) version, the water seal consist of a cap with a bellville spring washer and a temperature rating of 165*F (74°C). The recessed assembly forthe HSWX (Bulb & Link) should be a steel two pieces escutcheon with 1/2" adjustment (Model F2) standard finish should be Bright Chrome and white paint- ed. The F1 Res 58 HSW is also available with low lead frame. F1 Res 58 HSW and HSWX sprinklers shall have a nominal K Factor of 5.8 and F1 Res 44 a nominal K factor of 4.4. Standard finish: [Bronze] [Chrome -plated] [White Polyester] [Special finish- specify]. Residential horizontal sidewall sprinklers shall be Reliable Model F1 Res 44, F1 Res 58, F1 Res 58 HSWX & Model KRes58 HSWX, SIN R3531, RA3533 & RA3593 (Bulletin 135). Model F1 Res 44 Recessed Horizontal Sidewall Sprinkler Use description for the Model F1 Res 44 horizontal side- wall sprinkler with the following modifications: Replace "horizontal sidewall sprinkler" with "recessed horizontal sprinkler." Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with 1/2" adjustment (Model 172). Standard finish shall be [brass][bright chrome] [white painted] [Special finish- specify]. Residential recessed horizontal sidewall sprinklers shall be Reliable Model F1 Res 44/F2, SIN P3531 (Bulletin 135). Model F1 Res 76 Pendent Sprinklers shall be [cULus Listed] low flow residential pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprin- klers shall be installed in conformance with the manufac- turer's installation guidelines and the applicable installa- tion standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3/a" NPT thread. Wa- ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (790C)] Sprinklers shall have a nominal K -factor of 7.6. Standard finish: [Bronze] [Chrome -plated] [White Polyester] [Spe- cial finish- specify]. Residential pendent sprinklers shall be Reliable Model F1 Res 76, SIN R7618 (Bulletin 135). 11. Model F1 Res 76 Recessed Penderi l , Model F1 Res 76 Recessed Penderil Model F1 Res 76 Recessed Penderil Sprinklers shall be [cULus Listed] low flow residential recessed pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manu- facturer's technical data sheets are to be used. Residen- tial sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3/a" NPT thread. Water seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and hav- ing a temperature rating of [155°F (68°C)] [175°F (790C)]. Sprinklers shall have a nominal K -factor of 7.6. Standard finish: [Bronze] [Chrome -plated] [White Polyester] [Spe- cial finish— specify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with t/2" adjust- ment (Model F2)] [with 3/a" adjustment (Model F1)] [of push -on and thread off design with'/2" adjustment (Mod- el FP)]'. Standard finish shall be [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable [Model F1 Res 76 Recessed Pendent/ F11 [Model F1 Res 76 Recessed Pendent/F2] [Model F1 Res 76 Recessed Pendent/FP] SIN R7618 (Bulletin 135). Model F1 Res 76 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] low flow residential concealed sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are t0 be used. Residential sprin- klers shall be installed in conformance with the manufac- turer's installation guidelines and the applicable installa- tion standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3/4" NPT thread. Wa- ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having 'DuPont Registered Trademark a temperature rating of 155°F (680C). Cover plate assem- bly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push -on and thread -off design allowing a'/2" cover plate adjustment. Cover plate tem- perature rating shall be 135°F (570C). A plastic protec- tive cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color— specify]. ]. Concealed pendent sprinklers shall be Reliable Model F1 Res 76 CCfP, SIN 87618 (Bulletin 135). Finishes (1) Other finishes and colors are available on special order. Consult factory for details. c2 cULus listed Corrosion Resistant ll Paint or any other coating applied over the factory finish will void all approvals and warranties. Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Temperature Rating 4, Sprinkler Finish 5. Escutcheon Finish 6. Cover Plate Finish The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fre Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries.. Manufactured by Reliable Automatic Sprinkler Co., Inc. AM Recycled 0 (800) 431-1588 Sales Offices Paper liabi 118 ($00) $4$-6051 Sales Fax Revision Imes indicate updated or new data. (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG. Printed in U,S.A. 06/15 PIN 9999970235 Standard Finishes Sprinkler F1, F2, FP Cover Plates Escutcheons Bronze Brass White Painted Chrome Plated Bright Chrome Plated Chrome White and Black White Painted Polyester(2) Coated Special Application Finishes Sprinkler F1, F2, FP Escutcheons Electroless Nickel PTFE(Teflon®)«) Electroless Nickel PTFE (Teflon®) Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off while Chrome Dull Chrome Dull Other finishes and colors are available on special order. Consult factory for details. c2 cULus listed Corrosion Resistant ll Paint or any other coating applied over the factory finish will void all approvals and warranties. Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Temperature Rating 4, Sprinkler Finish 5. Escutcheon Finish 6. Cover Plate Finish The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fre Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries.. Manufactured by Reliable Automatic Sprinkler Co., Inc. AM Recycled 0 (800) 431-1588 Sales Offices Paper liabi 118 ($00) $4$-6051 Sales Fax Revision Imes indicate updated or new data. (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG. Printed in U,S.A. 06/15 PIN 9999970235 tqcoFire & Building Products Technical Services: Tel: (800) 381-93121 Fax: (800) 791.5500 Model 513 (1 1-112 thru 61 For NFPA 13 General Description 3) Riser M nch (DN40 Sprinkler The Figure 513 (13) Riser Manifolds described in this technical data sheet provide the necessary waterflow alarm, pressure gauge, alarm test ori- fice, drain, and sight glass equipment in a single assembly for use in NFPA 13 sprinkler systems as follows: NFPA 13` • 1-112 Inch (DN40) Male Thread x Female Thread • 1-112 thru 6 Inch (DN40 thru DN150) Groove x Groove `Although the Riser Manifold described in this data sheet is intended for NFPA 13 sprinkler systems, it may be used for NFPA 13D or 13R residential sprinkler systems, where a test orifice of 5.6K (80K) is accept- able. The variety of sizes and grooved end connections allow cost effective and easy transition to check valves, control valves, and system piping. The Riser Manifolds may be installed in either the horizontal (flow switch on top) or verti- cal (flow going up) for both single sprinkler rises and floor control in high rises, WARNING The Riser Manifolds described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation, in addition to the standards of any other authorities having jurisdic- tion. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. anifold thru DN150) Systems Technical Data Approvals The Figure 513 (13) Riser Manifolds with a cover tamper switch for the wa- terflow alarm switch are UL Listed, ULC Listed, and FM Approved, The Figure 513 (13) Riser Manifolds without a cover tamper switch for the waterflow alarm switch are UL Listed and FM Approved. Maximum Working Pressure 175 psi (12,1 bar) Test Orifice 5.6K (80K) Assembly The manifold body of the Figure 513 is ductile iron, whereas the manifold body of the Figure 13 is cast iron. The two assemblies are completely inter- changeable in function, application, and end-to-end laying length. Finish Red painted. Installation The Riser Manifolds may be installed in either the horizontal (flow switch on top) or vertical (flow going up). The inlet of the Riser Manifold may be di- rectly connected to a shut-off control valve, NOTES Where applicable pipe thread sealant is to be applied sparingly. Use of a non -hardening pipe thread sealant is recommended. Never remove any piping component nor correct or modify any piping defi- ciencies without first depressurizing and draining the system. Step 1. Install the manifold body with the flow arrow pointing in the down- stream position using threaded con- nections and/or listed mechanical grooved connections, as applicable Step 2. Connect the drain line, and then close the drain valve. Step 3. Refer to Figure 3 for wiring guidance. All wiring must be per- formed in accordance with the Author- ity Having Jurisdiction and/or the Na- tional Electrical Code, Step 4. Refer to Figure 4 for optional relief valve. Step 5. Place the system in service by filling the system with water. When fill- ing the system, partially open the con- trol valve to slowly fill the system. Fill- ing the system slowly will help avoid damaging the waterflow alarm switch After the system is fully pressurized, completely open the control valve. Step 6. Secure all supply valves open. Page 1 of 6 APRIL, 2006 TFP962 Page 2 of 6 NO. DESCRIPTION QTY. P/N 1 1-112" Manilold Body, Male x Female NPT..... 1 NIA Groove x Groove ....... 1 NIA 2 WatedbwAlarm Switch: VSR-SF with Paddle, UL/FM ............... 1 971-096-00 VSR-SF with Paddle and Cover Tamper Switch, ULCJFM .............. 1 976-519-02 3 300 psi12000 kPa Water Pressure Gauge .. 1 2341 NOTES: 1. Approximate weight, 11.2 lbs. (5,1 kg). 2. ULC Listed Manifolds are equipped with Cover Tamper SwRches installed internal to the Waterflow Alarm Switches, 3. CH: Common Hardware tacv,r 1111111 FIGURE 1 1.112 INCH (DN40) RISER MANIFOLD ASSEMBLY AND DIMENSIONS 3-112" (88,9 mm) TFP962 TFPS62 2 INCH (DN50) MANIFOLD NO. DESCRIPTION QTY. PIN 1 2" Manifold Body, Groove x Groove ....... 1 N/A 2 Waterflow Alarm Switch: VSC with Paddle, ULIFM ......... 1 976-357-01 VSC with Paddle and Cover Tamper Switch, ULC/FM .............. 1 976-520-01 3 300 psG2000 kPa Water Pressure Gauge .. 1 2341 2.112 INCH (DN65) MANIFOLD NO. DESCRIPTION QTY. PIN 1 2-172" Manifold body, Weight Groove x Groove ....... 1 NIA 2 Waterflow Alarm Switch: D VSC with Paddle, I F UUFM ............... 1 976-357-02 VSC with Paddle and 2Inch Cover Tamper Swkch, 13 LEC/FM .............. 1 976-520-02 3 300 psV2000 kPa 13-1116 Water Pressure Gauge .. 1 2341 3 INCH (DN80) MANIFOLD NO. DESCRIPTION QTY PIN 1 3" Manifold Body, Weight Groove x Groove ....... 1 NIA 2 Waterflow Alarm Switch: D VSC with Paddle, I F UUFM ............... 1 976-357-03 VSC with Paddle and 2Inch Cover Tamper Switch, 13 ULCIFM ..............1 976-520-03 3 300 psY2000 kPa 13-1116 Water Pressure Gauge .. 1 2341 NOTES: 1, ULC Listed Manifolds are equipped with Cover Tamper Switches installed internal to the Waterflow Alarm Switches. 2. CH: Common Hardware 4INCH (DN100) MANIFOLD NO. DESCRIPTION QTY, PIN 1 4" Manifold body, Weight Groove x Groove ....... 1 NIA 2 Waterflow Alarm Switch: D VSC with Paddle, I F ULIFM ............... 1 976-357-04 VSC with Paddle and 2Inch Cover Tamper Switch, 13 U LCIFM .............. 1 976-520-04 3 300 psi/2000 kPa 13-1116 Water Pressure Gauge .. 1 2341 Page 3 of 6 6 INCH (DN150) MANIFOLD NO. DESCRIPTION QTY. PIN 1 6" Manifold Body, Weight Groove x Groove ....... 1 NIA 2 Waterflow Alarm Switch: D VSC with Paddle, I F ULIFM ............... 1 976-357-05 VSC with Paddle and 2Inch Cover Tamper Switch, 13 ULCIFM .............. 1 976-520-05 3 300 pst12000 kPa 13-1116 Water Pressure Gauge .. 1 2341 Manifold Nominal Installation Dimensions in Inches and (min) Drain Size Weight A B C D E I F G H Size lbs. (kg) 2Inch 16-314 13 9116 5-318 6-318 13-1116 3-1121" NPT 13.5 (DN50) (425,5) (330,2) (14,3) (136,5) (161,9) (331,8) (88,9) (6,1) 2-112 Inch 17-3/16 13 1 5-314 6-718 13-314 3-112 1-114" NPT 16.8 (DN65) (436,6) (330,2) (25,4) (146,1) (174,6) (349,3) (88,9) (7,6) 3 Inch 17-3116 13 1 6 7-1/8 14-114 3-1121-114" NPT 18.7 (DN80) 436,6) 330,2) 25,4 152,4 181,0 362,0 88,9) (8,5) 4 Inch 20-112 13 4-5116 7-9116 9-1116 16.518 4-1122" NPT 32.7 (DN100) (520,7) (330,2) (109,5) (192,1) (230,2) (422,3) (114,3) (14,8) 6Inch 20-112 13 4-5116 B-112 10 18-112 6-5182" NPT 41.6 DN150 520,7 330,2 109,5 215,9 254,0 469,9 168,3 18,9 1 Drain Valve (Normally Closed) A B 3 i uo -114 �I Test C D & Drain Valve V (Normally set E to "Drain") H F FIGURE 2 2 thru 61NCH (011150 thru DN150) RISER MANIFOLD ASSEMBLY AND DIMENSIONS Page 4 of 6 TFP962 SWITCH TERMINAL CONNECTIONS UNINSULATED CLAMPING SEVERED LOOPED SECTION CAUTION: PLATE STRIPPED SINGLE An uninsulated section of a TERMINAL ENDS CONDUCTOR single conductor is not SEPARATE permitted to be looped around CONDUCTORS CLAMPING the terminal and serve as two PLATE separate connections. The TERMINAL wire must be severed to serve INCOMING as two separate connections, thereby providing supervision of the connection in the event that the wire becomes dislodged from the terminal. OUTGOING IMPROPER CONNECTION METHOD PROPER CONNECTION METHOD WATERFLOW SWITCH TYPICAL ELECTR ICA CONNECTIONS CONTACTS .......... SPDT (Farm C) LOCAL END OF LINE CONTACT RATING .... 5A 0 125 VAC SIGNAL 2.5A e 30 VDC DEVICE RESISTOR NC_ NO NC NO NOD /� NC COM f!/ COM COM CONTROL POWER PANEL NO FLOW NON -SUPERVISED STYLE BICLASS B CONDITION CIRCUIT SUPERVISED CIRCUIT (SEE NOTE) NOTE: For supervised circuits, see "Switch Terminal Connections" above. The Waterflow Alarm Switch has two switches, one can be used to operate a central station, proprietary or remove signaling unit, while the other contact is used to operate a local audible or visual annunciator. COVER TAMPER SWITCH (ULC ASSEMBLIES ONLY) CONTACTS ...... ... SPDT (Form C) CONTACT RATING .... 3A C 250 VAC 5AOe 125 VAC 1 mA @ 5 VDC min. NO % S NC COM CONTACTS SHOWN WITH COVER IN PLACE FIGURE 3 WIRING GUIDANCE TFP962 Page 5 of 6 NO. DESCRIPTION QTY. PIN NO. DESCRIPTION QTY. PIN 1-112" ll opts ManifoldPess Only; To install optional Pressure Relief Trim on 1 318" Copper Tubing, 2 Pressure Relief Valve, a 1-112" (ON40) Manifold, a 112" NPT outlet 2" (DN50) Manifolds .... 1 971-124-01 175 psi, Nonadjustable .. 1 198-066-00 must be provided by the installer on the 2-112" (DN65) and 3 90° Compression Fitting system outlet piping, and a connection back 3" (DN80) Manifolds .... 1 971-124-02 Fitting... , .... .... 2 CH to the manifold drain trim must be fabricated 4" (DN 100) and 4 1" x 112" Reducing Hex with installer supplied 318" copper tubing. 6" (DN150) Manifolds ... 1 971.124-03 Bushing .... 1 CH Discard unused trim components. CH: Common Hardware 3 112" NPT Installer Outlet Provided 1 3 4 System Outlet Piping Installer Fabricated 2 �j 318" Copper 2 Q Tubing 3 2" (DN50), 2.1/2" (DN65), T Q 3" (DN80), 4" (DN100), or Y 6" (DN150) Manifold q P 3 Manifold Drain Trim 1-112" (DN40) ® Manifold Li FIGURE 4 OPTIONAL PRESSURE RELIEF VALVE Care and Maintenance The following inspection procedure must be performed as indicated, in ad- dition to any specific requirements of the NFPA, and any impairment must be immediately corrected. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The in- stalling contractor or product manufac- turer should be contactedrelative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. NOTES No attempt is to be made to repair any Riser Manifold component in the field. Only the pressure gauge, waterflow alarm switch, or relief valve can be replaced. if any other problems are encountered the entire riser manifold must be replaced. The alarm/flow test procedure will re- sult in operation of the associated alarms. Consequently, notification must be given to the owner and the fire department, central station, or other signal station to which the alarms are connected, and notification must be given to the building occupants. Before closing a fire protection system control valve for inspection or mainte- nance work on the fire protection sys- tem that it controls, permission to shut down the effected fire protection sys- tem must first be obtained from the proper authorities and all personnel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central sta- tion alarms.. Alarm/Flow Test Procedure Step 1. Place the test & drain Valve in the "test" position. Step 2. Fully open the drain valve. Make certain that drainage water will not cause any damage or injury. Step 3. Verify operation of associated alarms. Step 4. Close the drain valve. Step 5. Place the test & drain Valve in the "drain" position. Step 6. Verify that the residual (flow- ing) pressure Indicated by the pres- sure gauge is no less that originally recorded for the system when it was first installed. Step 7. Close the drain valve. Step 8. Verify that the static (not flow- ing) pressure indicated by the pres- sure gauge is no less that originally recorded for the system when it was first installed. Page 6 of 6 TFP962 Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The fnregniog warranty is made in lieu of any and all other warranf(C,a, ex- nress_or implied. including warranties of merchantability and fitness for a fL titularur}� Dose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the fullex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Information Riser Manifold: Specify; Size (specify), Figure 513, (specify connection type Inlet x outlet) Riser Manifold (specify - without or with) a cover tamper switch for the waterflow, alarm switch, PIN (specify). NOTES Orders for Figure 513 may be filled with a Figure 13. The two assemblies are completely interchangeable in function, application, and end-to-end laying length. If a ULC Listing is required, the Riser Manifold must be ordered with a cover tamper switch for the waterflow alarm switch. UUULCIFM Assemblies PIN 4055 With Cover Tamper Switch 1-112 Inch (DN40) PIN 4056 MT x FT .............. PIN 4086 1-112 Inch (DN40) PIN 4060 MT x MT .............. PIN 4087 2 Inch (DN50) PIN 4061 G x G ................ PIN 4090 2.112 Inch (DN65) PIN 4062 G x G ................ PIN 4091 3 Inch (DN80) PIN 4065 G x G ................ PIN 4092 4 Inch (DN100) PIN 4066 G x G ................ PIN 4095 6 Inch (DN150) G x G ................ PIN 4096 UL/FM Assemblies Without Cover Tamper Switch 1-112 Inch (DN40) MT x FT .............. PIN 4055 1-112 Inch (DN40) MT x MT .............. PIN 4056 2 Inch (DN50) G x G ................ PIN 4060 2-112 Inch (DN65) G x G ................ PIN 4061 3 Inch (DN80) G x G ................ PIN 4062 4 Inch (DN100) G x G ................ PIN 4065 6 Inch (DN150) G x G ................ PIN 4066 Optional Pressure Relief Valve: Specify: Operational Pressure Relief Valve and Trim for use with (specify size) Figure 513 or 13 Series Riser Manifold, PIN (specify). 1.112' or 2' ............... PIN 4063 2-112" or 3' ............... PIN 4072 4" or 6' .................. PIN 4073 Replacement Parts: Specify: (description) for use with Fig- ure 513 or 13 Riser Manifold, PIN (Ref. Figure 1 or 2, as applicable). TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446