Loading...
HomeMy WebLinkAboutPLANS FIRE ALARM - 16-00599 - 285 S 1st W - Kimball Remodel Rooms 170, 244, 250KIMBALL BUILDING BYU -IDAHO FIRE ALARM SYSTEM INDEX OF DRAWINGS SYMBOL DESCRIPTION PART NUMBER MOUNTING REQUIREMENT PAGE SHEET # DESCRIPTI❑N H SPEAKER/STROBE— WALL SPSW 4 SQ. 2-1/8" DEEP BOX MINIMUM w/1-1/2' EXT, RING ge SPEAKER/STROBE— CEILING FA—C-01 PROJECT COVER SHEET / INDEX OF DRAWINGS NELSON FIRE SYSTEMS 2 FA—R-01 FIRE ALARM BUILDING RISER DIAGRAM / MATRIX NELSON FIRE SYSTEMS 3 F41 FA -1-01 LEVEL 1 & 2— ADDRESSABLE CIRCUITS NELSON FIRE SYSTEMS FA -1-02 LEVEL 1 & 2— NOTIFICATION CIRCUITS NELSON FIRE SYSTEMS DEVICE SCHEDULE SYMBOL DESCRIPTION PART NUMBER MOUNTING REQUIREMENT ® SMOKE DETECTOR w/BASE ASD—PL2F w/B210LP 3/0 MUD RING H SPEAKER/STROBE— WALL SPSW 4 SQ. 2-1/8" DEEP BOX MINIMUM w/1-1/2' EXT, RING ge SPEAKER/STROBE— CEILING SPSCW 4 SQ. 2-1/8" DEEP BOX MINIMUM w/1-1/2" EXT. RING FIRE ALARM CONTROL UNIT EXISTING EXISTING TO REMAIN ® TRANSPONDER EXISTING (NEW HP—FF8)l SUPPLIED BY NFS, FOLLOW MANUFACTURERS INSTRUCTI❑NS, CE�TI.ICAT o kIP4596 J W W � O O � W W N F --- of of 0 00 � o of Q W o N o_za� J ILu ry U Q J m> - Q J m H D W J m ry m ON W LL Lory N L0 NIPS NELSON FIRE SYSTEMS 801-468-8300 DRAWN BY: BDT DESIGNED BY: XXXX APPROVED BY: DS DATE: 10/19/2016 SCALE: (ANSI B) 1/16°=1' PROJECT NO: XXXX REV NO: XXXX DRAWING NAME: BYU-I KIMBALL IST & 2ND C.DWG FIRE ALARM SYSTEM COVER SHEET PAGE: FA -C-01 FIRE ALARM INPUT/OUTPUT SYMBOL DESCRIPTI❑N 0 SMOKE DETECTOR 9C MEMEMIMEE SS SPEAKER/STROBE Ac EIRE ALARM CONTROL UNIT TRA TRANSPONDER PANEL Ex EXISTING DEVICE SYSTEM INPUTS BASEMENT LEVEL- SM13KE DETECMRS a:❑■■■a❑❑■■■■■■■■■■■■■a■❑■■ LEVEL 1- SMOKE DETECTORS ■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■ ii❑❑iiONE MEMO MENiiiiiii❑❑ii LEVEL 2 DEVICE LEGEND SYMBOL DESCRIPTI❑N 0 SMOKE DETECTOR 9C CEILING SPEAKER/STROBE SS SPEAKER/STROBE Ac EIRE ALARM CONTROL UNIT TRA TRANSPONDER PANEL Ex EXISTING DEVICE SYSTEM NOTES: < REINSTALL EXISTING SMOKE DETECTOR IN NEW L❑CATI❑N O S EX S EX S EX S EX ADDRESSABLE CIRCUIT 1 PAIR #14'S TWISTED S EX S EX S EX D❑ NO USE SHIELDED WIRE ❑N ADDRESSABLE CIRCUIT SPEAKER CIRCUIT 1 PAIR #14'S TWISTED SHIELDED (2) STROBE CIRCUITS 4 #14'S IMXO" WTO TIP NMMUN BB' TO BOTTOM HORN/STROBE VICE MOUNTED MTOP AT 60' µ AT 60'B li T13P AT 48. F ALAIN4 PILL STATION LEVEL 2 x Q� Lu ��'o37 Z Q~r� E O 00 N �aaL`" m Z Q J I UJ U Q � `J mmch =) Lu 0 co N X LIJ anch Q N Lu r' LL- NFS NELSON FIRE SYSTEMS 801-468-8300 DRAWN BY: BDT DESIGNED BY: XXXX APPROVED BY: ZM DATE: 10/18/2016 SCALE: (ANSI B) 1/16"=1' PROJECT NO: XXXX REV NO: XXXX DRAWING NAME: BYU-I KIMBALL IST B 2ND R.DWG FIRE ALARM SYSTEM RISER DIAGRAM / MATRIX PAGE FA -R-01 GENERAL NOTES: I. INSTALLATION SHALL COMPLY WITH NEC, NFPA 72 AND ALL OTHER APPLICABLE CODES AS REQUIRED BY THE LOCAL AUTHORITY HAVING JURISDICTION. CLASS "A" WIRING IS REQUIRED. 2. WIRING DEPICTED ON THESE PLANS IS SCHEMATIC - ACTUAL WIRE LOCATIONS MAY DIFFER FROM THESE PLAN. WIRING SHALL BE PERFORMED AS ACTUAL BUILDING CONSTRUCTION CONDITIONS ALLOW AND TO MINIMIZE PENETRATIONS THROUGH AREA SEPARATION WALLS AND FIRE WALLS. THE USE OF A RACEWAY IS PERMITTED AS LONG AS NO 110V OR HIGHER VOLTAGE CABLES ARE IN THE SAME RACEWAY. 3. POWER -LIMITED AND NONPOWER -LIMITED CIRCUIT WIRING MUST REMAIN SEPARATED IN CABINET. ALL POWER -LIMITED CIRCUIT WIRING MUST REMAIN AT LEAST 0.25" AWAY FROM ANY NONPOWER -LIMITED CIRCUIT WIRING. FURTHERMORE, ALL POWER -LIMITED AND NONPOWER -LIMITED CIRCUIT WIRING MUST ENTER AND EXIT THE CABINET THROUGH DIFFERENT KNOCK OUTS AND/OR SEPARATE CONDUITS. 4. SMOKE DETECTORS SHALL BE INSTALLED AND COVERED UNTIL TESTING AND FINAL INSPECTION ARE COMPLETED. DO NOT INSTALL SMOKE DETECTORS UNTIL BUILDING IS CLEAN. 5 -LOCATE SMOKE DETECTORS A MINIMUM OF THREE (3) FEET FROM MECHANICAL DIFFUSERS. 6. PROVIDE SYNCHRONIZATION OF ALL VISUAL NOTIFICATION APPLIANCE CIRCUITS. PROVIDE ALL REQUIRED SYNC MODULES. A MULTI -SYNC MODE SLAVE CONNECTION BETWEEN ALL SYNC MODULES. 7. ONLY FIRE ALARM WIRING IS PERMITTED IN FIRE ALARM CONDUIT. 110V OR HIGHER VOLTAGE CABLES ARE NOT ALLOWED IN FIRE ALARM CONDUIT. 8. DO NOT USE SHIELDED WIRE ON ADDRESSABLE CIRCUITS. 9. FIRE ALARM CIRCUITS NEED TO BE FREE OF GROUNDS, FAULTS, AND SHORTS PRIOR TO CONNECTION TO FIRE ALARM EQUIPMENT. IO.A SMOKE DETECTOR MUST BE IN EVERY ROOM WITH A ARE ALARM CONTROL UNIT, POWER SUPPLY, OR ANNUNCIATOR. II. DEDICATED 120 VAC CIRCUITS WILL BE MARKED AS "FIRE ALARM CIRCUIT" AND BE ACCESSIBLE ONLY TO PERSONNEL. DISCONNECTS FOR THESE CIRCUITS WILL BE RED IN COLOR AND THEIR LOCATION WILL BE NOTED AT EACH CONTROL UNIT. I � I A ,oEX —A 0' I 10' I 20' 25' SCALE LEVEL 1 UP — SCOPE OF WORK WIRE SCHEDULE SYMBOL DESCRIPTI❑N Q SMOKE DETECTOR NOTE DESCRIPTI❑N ss WIRES ac A ADDRESSABLE CIRCUIT TRANSPONDER PANEL 1 PAIR #14'S TWISTED B RELAY CIRCUIT 2 #14'S C 24 VDC AUX POWER 2 #14'S D 120 VAC POWER 3 #12'S 1 PAIR #14'S TWISTED/SHIELDED E SPEAKER CIRCUIT F STROBE CIRCUIT 2 #14'S G LOCAL OPERATING CONSOLE 1 PAIR #14'S 1 PAIR #14'S 2 #14'S TWISTED TWISTED/SHIELDED A ,oEX —A 0' I 10' I 20' 25' SCALE LEVEL 1 UP — SCOPE OF WORK SYSTEM NOTES: <T> TO EXISTING FACU Q TO NEW HP—FF8 TO BE ADDED TO EXISTING TRANSPONDER <3> REINSTALL EXISTING SMOKE DETECTOR IN NEW L❑CATI❑N ® REINSTALL EXISTING DEVICE IN SAME L❑CATI❑N SCOPE OF WORK LEVEL 2 N.I. `.. C.T. CFRTI�"Ii ATJDI� i � IFE FyLARF13Y5�' T�-c_ us r r W s '6ZZ W ' F O O Z �o oa3E 3 U 0'Nw_a OZQ0 W Q W N W UJ N J Z O a o a N &Nad x d z w a a z wui� o< LL r 2 Z Z 0 o w F o 3 r W W� 2 J O Q W d Z N W N y ¢] p S m J ro Z � ~aZ Z Q Z N z o 2 W�WaF� awZ ~o-6z-z� 00 �n .zZzwzw -. u �opow Z F F J a d J t7 Z J 3uamz azamui � u F to U W N U Z W W> W o �awooxxww zza,na a J W N W 0 W O O co `O Lu C C N N oc) WO N W Q Z_ Q H i J W cOf J Z U _ Q M m Q ILQ J = m W Q U O X Ir m O W LL _j Lr) O� LL N Y Ln NFS NELSON FIRE SYSTEMS 801-468-8300 DRAWN BY: BDT DESIGNED BY: XXXX APPROVED BY: ZM DATE: 10/19/2016 SCALE: (ANSI B) 1/16"= I' PROJECT NO: XXXX REVISION NO: XXXX DRAWING NAME: BUY -I KIMBALL IST 8 2ND.DWG NELSON FIRE SYSTEMS FLOORPLAN LEVELS 18 2 ADDRESSABLE PAGE: FA -1-01 DEVICE LEGEND SYMBOL DESCRIPTI❑N Q SMOKE DETECTOR 9c CEILING SPEAKER/STROBE ss SPEAKER/STROBE ac FIRE ALARM CONTROL UNIT as TRANSPONDER PANEL EX EXISTING DEVICE SYSTEM NOTES: <T> TO EXISTING FACU Q TO NEW HP—FF8 TO BE ADDED TO EXISTING TRANSPONDER <3> REINSTALL EXISTING SMOKE DETECTOR IN NEW L❑CATI❑N ® REINSTALL EXISTING DEVICE IN SAME L❑CATI❑N SCOPE OF WORK LEVEL 2 N.I. `.. C.T. CFRTI�"Ii ATJDI� i � IFE FyLARF13Y5�' T�-c_ us r r W s '6ZZ W ' F O O Z �o oa3E 3 U 0'Nw_a OZQ0 W Q W N W UJ N J Z O a o a N &Nad x d z w a a z wui� o< LL r 2 Z Z 0 o w F o 3 r W W� 2 J O Q W d Z N W N y ¢] p S m J ro Z � ~aZ Z Q Z N z o 2 W�WaF� awZ ~o-6z-z� 00 �n .zZzwzw -. u �opow Z F F J a d J t7 Z J 3uamz azamui � u F to U W N U Z W W> W o �awooxxww zza,na a J W N W 0 W O O co `O Lu C C N N oc) WO N W Q Z_ Q H i J W cOf J Z U _ Q M m Q ILQ J = m W Q U O X Ir m O W LL _j Lr) O� LL N Y Ln NFS NELSON FIRE SYSTEMS 801-468-8300 DRAWN BY: BDT DESIGNED BY: XXXX APPROVED BY: ZM DATE: 10/19/2016 SCALE: (ANSI B) 1/16"= I' PROJECT NO: XXXX REVISION NO: XXXX DRAWING NAME: BUY -I KIMBALL IST 8 2ND.DWG NELSON FIRE SYSTEMS FLOORPLAN LEVELS 18 2 ADDRESSABLE PAGE: FA -1-01 GENERAL NOTES: I. INSTALLATION SHALL COMPLY WITH NEC, NFPA 72 AND ALL OTHER APPLICABLE CODES AS REQUIRED BY THE LOCAL AUTHORITY HAVING JURISDICTION. CLASS "A" WIRING IS REQUIRED. 2. WIRING DEPICTED ON THESE PLANS IS SCHEMATIC - ACTUAL WIRE LOCATIONS MAY DIFFER FROM THESE PLAN. WIRING SHALL BE PERFORMED AS ACTUAL BUILDING CONSTRUCTION CONDITIONS ALLOW AND TO MINIMIZE PENETRATIONS THROUGH AREA SEPARATION WALLS AND FIRE WALLS. THE USE OF A RACEWAY IS PERMITTED AS LONG AS NO 110V OR HIGHER VOLTAGE CABLES ARE IN THE SAME RACEWAY. 3. POWER -LIMITED AND NONPOWER -LIMITED CIRCUIT WIRING MUST REMAIN SEPARATED IN CABINET. ALL POWER -LIMITED CIRCUIT WIRING MUST REMAIN AT LEAST 0.25" AWAY FROM ANY NONPOWER -LIMITED CIRCUIT WIRING. FURTHERMORE, ALL POWER -LIMITED AND NONPOWER -LIMITED CIRCUIT WIRING MUST ENTER AND EXIT THE CABINET THROUGH DIFFERENT KNOCK OUTS AND/OR SEPARATE CONDUITS. 4. SMOKE DETECTORS SHALL BE INSTALLED AND COVERED UNTIL TESTING AND FINAL INSPECTION ARE COMPLETED. DO NOT INSTALL SMOKE DETECTORS UNTIL BUILDING IS CLEAN. 5 -LOCATE SMOKE DETECTORS A MINIMUM OF THREE (3) FEET FROM MECHANICAL DIFFUSERS. 6. PROVIDE SYNCHRONIZATION OF ALL VISUAL NOTIFICATION APPLIANCE CIRCUITS. PROVIDE ALL REQUIRED SYNC MODULES. A MULTI -SYNC MODE SLAVE CONNECTION BETWEEN ALL SYNC MODULES. 7. ONLY FIRE ALARM WIRING IS PERMITTED IN FIRE ALARM CONDUIT. 110V OR HIGHER VOLTAGE CABLES ARE NOT ALLOWED IN FIRE ALARM CONDUIT. 8. DO NOT USE SHIELDED WIRE ON ADDRESSABLE CIRCUITS. 9. FIRE ALARM CIRCUITS NEED TO BE FREE OF GROUNDS, FAULTS, AND SHORTS PRIOR TO CONNECTION TO FIRE ALARM EQUIPMENT. IO.A SMOKE DETECTOR MUST BE IN EVERY ROOM WITH A ARE ALARM CONTROL UNIT, POWER SUPPLY, OR ANNUNCIATOR. II. DEDICATED 120 VAC CIRCUITS WILL BE MARKED AS "FIRE ALARM CIRCUIT" AND BE ACCESSIBLE ONLY TO PERSONNEL. DISCONNECTS FOR THESE CIRCUITS WILL BE RED IN COLOR AND THEIR LOCATION WILL BE NOTED AT EACH CONTROL UNIT. SP1 -7 1/2W L2-1 15cSS d I 0 WIRE SCHEDULE SP1 -4 SS SP1 -6 C 1/2W SP1 -8 SS LI -6 0 1/2W 75cd L2-2 SS 75cd 0 HP-FF8 \ ® \ 0' I 10' I 20' 25' SCALE WIRE SCHEDULE SP1 -4 -5 SP1 SS 1/2W 75cd SS C 1/24 L1-4 1/2W ss 75cd L1-5 I5cd A ADDRESSABLE CIRCUIT HP-FF8 \ ® \ 0' I 10' I 20' 25' SCALE 1 SP1 -12 112W 1 L2-6 15cd WIRE SCHEDULE SP1 -10 LI SP2W 1/2W SS 1/2W 75cd SS C NOTE DESCRIPTI❑N ss WIRES SP1 -1 A ADDRESSABLE CIRCUIT SS 1 PAIR #14'S TWISTED B RELAY CIRCUIT \ E,F(2) 1 2 #14'S C 24 VDC AUX POWER SP1 -3 1/2W 2 #14'S i LI -3 lscd D 120 VAC POWER \ 'Ac 3 #12'S 1 PAIR #14'S TWISTED/SHIELDED E SPEAKER CIRCUIT F STROBE CIRCUIT 2 #14'S G LOCAL OPERATING CONSOLE 1 PAIR #14'S 1 PAIR #14'S 2 #14'S TWISTED TWISTED/SHIELDED 1 SP1 -12 112W 1 L2-6 15cd LEVEL 1 1 SP1 -10 LI SP2W 1/2W SS 1/2W 75cd SS C 15cd C CEILING SPEAKER/STROBE ss I SP1 -1 / 112W L1-1 SS 75cd SS C SP1 -9 1/2W L2-3 15cd \ E,F(2) 1 7 ss SP1 -3 1/2W / i LI -3 lscd \ \ 'Ac SP2W 1/24 Ll -2 75cd LEVEL 1 SYSTEM NOTES: <T> TO EXISTING FACU Q TO NEW HP—FF8 TO BE ADDED TO EXISTING TRANSPONDER <3> REINSTALL EXISTING SMOKE DETECTOR IN NEW L❑CATI❑N �E,F(2) ® REINSTALL EXISTING DEVICE IN SAME L❑CATI❑N i UP SCOPE OF WORK SCOPE OF WORK LEVEL 2 N.I. `.. C.T. CFRTI�"Ii ATJDI� i � IFE FyLARF13Y5�' T�-c_ us � } w s '6ZZ W ' F O O Z �o oa3E 3 U 0'Nw_a OZQ0 w Q W N W uJ N J Z 0 a o a N &Nad xdzwa aWZF wui� o< LL> W Z3: Z O o w F a r W W 2 J O Q w� z N W N y ¢] p S m J ro Z � ~aZ Z Q Z N z o 2 W�WaF� awZ ~-6z-z� 00 �n Z z wz?w za�„� u �owzpow Z F F J Q d J t7 Z J 3 ualr'z W zamui Q u ..p~ W p F a 3 w o F to U W N U Z W W> y o 'woo xxwwW zza,na J W N W 0 W O O co 'o Lu N (n 10 oc) O W O N W Q Z_ Q H J W cl Of J Z U _ Q mm_j < IL J = m W Q O O X Ir m O W LL_ J Lf) O� LL_ N Y L!7 NFS NELSON FIRE SYSTEMS 801-468-8300 DRAWN BY: BDT DESIGNED BY: XXXX APPROVED BY: ZM DATE: 10/19/2016 SCALE: (ANSI B) 1/16" = I' PROJECT NO: XXXX REVISION NO: XXXX DRAWING NAME: BUY -I KIMBALL IST 8 2ND.DWG NELSON FIRE SYSTEMS FLOORPLAN LEVELS 18 2 NOTIFICATION PAGE: FA -1-02 DEVICE LEGEND SYMBOL DESCRIPTI❑N Q SMOKE DETECTOR 9c CEILING SPEAKER/STROBE ss SPEAKER/STROBE ac FIRE ALARM CONTROL UNIT as TRANSPONDER PANEL EX EXISTING DEVICE SYSTEM NOTES: <T> TO EXISTING FACU Q TO NEW HP—FF8 TO BE ADDED TO EXISTING TRANSPONDER <3> REINSTALL EXISTING SMOKE DETECTOR IN NEW L❑CATI❑N �E,F(2) ® REINSTALL EXISTING DEVICE IN SAME L❑CATI❑N i UP SCOPE OF WORK SCOPE OF WORK LEVEL 2 N.I. `.. C.T. CFRTI�"Ii ATJDI� i � IFE FyLARF13Y5�' T�-c_ us � } w s '6ZZ W ' F O O Z �o oa3E 3 U 0'Nw_a OZQ0 w Q W N W uJ N J Z 0 a o a N &Nad xdzwa aWZF wui� o< LL> W Z3: Z O o w F a r W W 2 J O Q w� z N W N y ¢] p S m J ro Z � ~aZ Z Q Z N z o 2 W�WaF� awZ ~-6z-z� 00 �n Z z wz?w za�„� u �owzpow Z F F J Q d J t7 Z J 3 ualr'z W zamui Q u ..p~ W p F a 3 w o F to U W N U Z W W> y o 'woo xxwwW zza,na J W N W 0 W O O co 'o Lu N (n 10 oc) O W O N W Q Z_ Q H J W cl Of J Z U _ Q mm_j < IL J = m W Q O O X Ir m O W LL_ J Lf) O� LL_ N Y L!7 NFS NELSON FIRE SYSTEMS 801-468-8300 DRAWN BY: BDT DESIGNED BY: XXXX APPROVED BY: ZM DATE: 10/19/2016 SCALE: (ANSI B) 1/16" = I' PROJECT NO: XXXX REVISION NO: XXXX DRAWING NAME: BUY -I KIMBALL IST 8 2ND.DWG NELSON FIRE SYSTEMS FLOORPLAN LEVELS 18 2 NOTIFICATION PAGE: FA -1-02