Loading...
HomeMy WebLinkAboutFIRE ALARM SUBMITTAL - 16-00674 - 525 S Center St - BYUI - Clark Classroom Remodel FIRE CONTROL INSTRUMENTS-GAMEWELL-BOSCH 1481 SOUTH MAJOR STREET S.L.C., UT 84115 P. 801-468-8300 F. 801-468-8305 Clarke Building Remodel Levels 1 & 3 BYU-Idaho Fire Alarm System Submittal March 9, 2017 CLARKE BUILDING REMODEL LEVELS 1 & 3 BYU-IDAHO FIRE ALARM SYSTEM SUBMITTAL Equipment Manufacturer: Gamewell-FCI Authorized Distributor: Nelson Fire Systems 1481 South Major Street Salt Lake City, UT 84115 801-468-8300 Data Sheet Part No. Description Gamewell-FCI E3 Series Emergency Evacuation System (Existing) Gamewell-FCI ASD-PL2F/B210LP Addressable Photo Smoke Detector w/Base Gamewell-FCI ATD-RL2F/B210LP Addressable Heat Detector w/Base Gamewell-FCI MS-7AF Addressable Pull Station Gamewell-FCI SW Strobe Only – Wall Mount Gamewell-FCI SCW Strobe Only – Ceiling Mount Gamewell-FCI P2W Horn/Strobe – Wall Mount Gamewell-FCI P2RK Weatherproof Horn/Strobe – Wall Mount Gamewell-FCI HPFF8 NAC Power Supply GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2013 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0637 Rev. O page 1 of 2 E3 Series® Control Panel SIGNALING Class 1 Class 2 High Rise S1869 Approved City of Denver City of Chicago ApprovedApproved 7165-1703:0125 3025415 APPROVED FM FDNY: COA-#6077 MEA Reference Certificate of Compliance VMA-45894-02C (Revision 1) Description The E3 Series® Expandable Emergency Evacuation Sys- tem by Gamewell-FCI is in the forefront of the latest gener- ation of fire alarm control panels. Employing the new high- speed Velociti® sensors, the E3 Series provides previously unattainable polling speed and response together with the flexibility demanded by today’s emergency evacuation sys- tems. In addition to their high-speed polling rate, the Veloc- iti Series of sensors feature bi-polar LEDs that flash green for normal polling, and light red steadily to indicate an alarm. The E3 Series is equipped with an 80-character LCD-E3 alphanumeric LCD display that allows 40 characters to be user-defined for custom installations. Up to six keyboard LCD displays may also be remotely located. In addition, you can install five of the familiar LCD-7100/RAN-7100 remote displays. The displays show instant system status information and can be connected in any desired area of an installation. A high-speed 32-bit processor easily tackles a wide array of applications from small office buildings to multi-complex, high-rise installations. The 64 node networking is made possible by 625K baud/ ARCNET communications using twisted-pair copper cable, fiber-optic cable, or a combination of both. In addition, the Addressable Node Expander (ANX) board expands the network to 122 nodes. The basic E3 Series is equipped with an ILI-MB-E3/ILI95- MB-E3 Intelligent Loop Interface-Main Board, ILI-S-E3/ ILI95-S-E3 Intelligent Loop Interface Expansion Board, ANX, and ASM-16 Addressable Switch Module that fea- tures 16 software programmable switches, each accompa- nied by red, green and yellow LEDs that can be programmed to indicate operation of the switches. Addi- tional ASM-16 modules may be added to expand the oper- ation to a plateau previously unimagined. The Intelligent Loop Interface - Expansion Board (ILI-S-E3/ ILI95-S-E3 provides the E3 Series control panel with two additional signaling line circuits. The layout is similar to the ILI-MB-E3/ILI95-MB-E3 with the exception that a number of components are omitted. It occupies one node on the Broadband network. E3 Series® and Velociti® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. Features • IBC Seismic Certified. • Listed under UL ® Standard 864, 9th Edition. • UL Listed for smoke control (dedicated and non-dedi- cated) when properly configured. • FM/UL Listed for Pre-action/Deluge use. • Styles 4, 6, or 7* signaling line circuits. • Two to 244 SLCs each supporting 159 sensors and 159 modules. • 625K baud ARCNET communications using wire, fiber, or mixed configurations for installation flexibility. • High-speed 32 bit processor and 4100 event history log. • Advanced Boolean logic-based programming such as AND, OR, NOT, time delay and calendar functions configurable via computer programming. • Supports up to (16), ASM-16 addressable switch or ANU-48 LED driver modules per ILI-MB-E3/ILI95-MB-E3. • Two Class A, Style Z or Class B, Style Y, notification appliance circuits rated at 2.0 amps. per circuit. • Integral city connection. • Flexible 115,200 baud high speed RS-232 interface. • 40 character user-defined text per device. • Supports up to five LCD-7100/RAN-7100 displays and six LCD-E3 keyboard displays per ILI-MB-E3/ILI95-MB- E3. *Style 7 wiring requires the use of System Sensor M500X Isolator Modules. Expandable Emergency Evacuation System E3 Series GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9020-0637 Rev. O page 2 of 2 www.gamewell-fci.com Description (Continued) Each ILI-MB-E3/ILI95-MB-E3 can support as many as six- teen ANU-48 LED Driver modules supporting hundreds of LEDs on a 3rd party graphic annunciator for remote annun- ciation. The ANU-48 modules may be installed in any Listed remote annunciator. It can be remotely located via an RS-485 serial interface. An array of cabinets allows for neat, compact, attractive installations. Installation The E3 Series expandable emergency evacuation system offers four cabinet size options. A typical cabinet includes a backbox, an inner door, and an outer door. The E3 Series cabinet assembly is a compact 19 3/8” (49 cm) wide wall- mounted enclosure. Cabinet A includes the following four options: • Cabinet A1 inner door mounted to the backbox. The backbox houses one NGA module. • Cabinet A2 inner door mounted to the backbox. The backbox houses one LCD-E3 module. • Two or three-bay inner door mounted to the backbox. The backbox typically houses one LCD-E3, or one NGA, and one or two ASM-16 modules. Cabinet B contains a space for the ILI-MB-E3/ILI95-MB-E3, PM-9/PM-9G modules and batteries set inside the back- box. Additional module options mounted on the backbox include the DACT-E3, and RPT-E3 or ILI-S-E3/ILI95-S-E3/ ANX. The 2-bay inner door houses one LCD-E3 module and one ASM-16 module. Both Cabinets C and D include the following: • Pre-assembled outer door that gives visibility to the fire fighter’s phone handset and a microphone voice messaging system. • Two inner door panel selections that may contain optional modules to meet the facility operation requirements. In the Cabinet B, C and D backboxes, the ANX appears in the same place as the ILI-MB-E3/ILI95-MB-E3 and PM-9/ PM-9G. For information on the installation instructions for any of the E3 Series cabinets, refer to the E3 Series® Expandable Emergency Evacuation Installation/Operating Manual Part Number: 9000-0574. Features (Continued) Velociti ® Intelligent Sensor Features: • Poll 318 devices in less than two seconds. • Activate up to 159 outputs in less than five seconds. • LED’s blink associated device address during Walk Test. • Fully digital, hi-precision protocol. • Up to 9 levels of sensitivity adjustment. • Pre-Alarm adjustable between 15 levels for both Alert and Action. • Day/night automatic sensing adjustment. • Sensitivity windows: - Ion .05 to 2% obscuration. - Photo 1 to 3% obscuration. - Laser .02 to 2% obscuration. - MCS Acclimate2F .5 to 4%, also self-adjustable options 1 to 2%, 2 to 3%, and 3 to 4%. - HARSH 1 to 3% obscuration. • Drift compensation. • Each Loop Card has its own integral processor providing maximum survivability on loss of any other component. SLC provides full response on loss of any other system processor. • Optional programmable switches can be configured to enable, disable or group any combination of output devices. • Integrated point or Grouped Cross Zoning allows for numerous devices installed at any location to cooperate and determine alarm condition. • Automatic detector sensitivity testing. • DIRTY and VERY DIRTY detector maintenance alerts. Specifications Operating Voltage:24 VDC Operating Temperature: Not to exceed the range of 32° to 120° F (0 to 49° C) Relative Humidity:Not to exceed 93% non-con- densing at 90° F (32° C) Ordering Information Part Number Description ILI-MB-E3 Intelligent Loop Interface-Main Board ILI95-MB-E3 Intelligent Loop Interface-Main Board ILI-S-E3 Intelligent Loop Interface-Expansion Board ILI95-S-E3 Intelligent Loop Interface-Expansion Board ANX-SR Addressable Node Expander-Single Ring ANX-MR-FO Addressable Node Expander-Multi-Ring Fiber Optic ANX-MR-UTP Addressable Node Expander-Multi-Ring Twisted-pair LCD-E3 LCD-E3, LCD Keypad Display RPT-E3-FO RPT-E3-UTP Network Repeater (fiber and twisted-pair) Network Repeater (twisted-pair only) DACT-E3 Digital Alarm Communicator Transmitter ANU-48 ANU-48 LED Driver Module ASM-16 Addressable Switch Module NGA LCD Network Graphic Annunciator PM-9 Power Supply Module PM-9G Power Supply Module LCD-7100 Remote LCD Display RAN-7100 Remote LCD Display For additional information on the cabinets, refer to the E3 Series Cabinets data sheet (Part Number: 9020-0649). Seismic Battery Bracket Kits For information on the types of Seismic Battery Bracket Kits that are available, the Seismic Battery Bracket Kit Part Numbers and the installation instructions, refer to the following documents: • Seismic Battery Bracket Installation Guide, P/N: 53839 • E3 Series Cabinets Data Sheet, P/N: 9020-0649 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2013 by Honeywell International Inc. All rights reserved.www.gamewell-fci.com 9020-0617 Rev. J page 1 of 2 Velociti® Series ASD-PL2F, ASD-PTL2F and ASD-PL2FR Analog, Addressable Photoelectronic Smoke Sensor APPROVED FM 3023594 SIGNALING 7272-1703:0121S1913 MEAApproved FDNY COA #:219-02-E Vol.VI Description The Gamewell-FCI Velociti® Series, analog address- able plug-in smoke sensors with integral communica- tion provide features that surpass conventional sensors. Sensitivity can be programmed in the con- trol panel software, and is continuously monitored and reported to the panel. Point ID capability allows each sensor’s address to be set, providing exact locations for selective maintenance when the cham- ber contamination reaches an unacceptable level. The ASD-PL2F photoelectric sensor’s unique optical sensing chamber is engineered to sense smoke pro- duced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed-tem- perature thermal sensing on the ASD-PTL2F model. The Velociti® Series use a communication protocol that substantially increases the speed of communica- tion between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel’s microprocessor stops the group poll and concen- trates on the single device. The net effect is a response speed up to five times greater than earlier designs. Velociti® is a registered trademark of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. Ordering Information Part Number Description ASD-PL2F Analog, addressable photoelectronic smoke sensor ASD-PTL2F Analog, addressable photoelectronic smoke sensor with thermal sensing ASD-PL2FR Analog, addressable photoelectronic smoke sensor used with the DNR duct base when the remote test is required. Features • Sleek, low-profile design. • Visual rotary, decimal switch addressing (01-159). • Built-in functional test switch activated by an external magnet. • Bicolor LEDs flash green whenever the sensor is addressed, and light steady red on alarm.* • Optional relay, isolator, or sounder bases. • Low standby current. • Analog addressable communication. • Stable communication technique with noise immunity. • Optional remote, single-gang LED Indicator (RA100Z). • Compatible with Gamewell-FCI analog addressable panels. Note: *Only the red LED is operative in panels that do not operate in Velociti® mode. ASD-PL2FRASD-PL2F/ASD-PTL2F GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9020-0617 Rev. J page 2 of 2 www.gamewell-fci.com Installation ASD-PL2F plug-in sensors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug-in and remove sensors without using a ladder. Mount the base on a box which is at least 1.5" (3.8 cm) deep. Suitable mounting base boxes include: •4.0" (10.2 cm) square box. •3.5" (8.9 cm) or 4.0" (10.2 cm) octagonal box. • Single-gang box (except relay or isolator bases). • With B200S or B200SR base, mounted on a 4.0" (10.2 cm) octagonal or square box. • With B224RB or B224BI base, mounted on a 3.5" (8.9 cm) octagonal box, or a 4.0" (10.2 cm) octagonal or square box. NOTE: Because of the inherent supervision provided by the SLC, end-of-line resistors are not required. Wiring “T-taps” or branches are permitted for Style 4 (Class “B”) wiring. Sensor Spacing Gamewell-FCI recommends that the spacing sensors be used in compliance with NFPA 72. Specifications ASD-PL2F, ASD-PTL2F, ASD-PL2FR: Dimensions:2.1” (5.1 cm) height Diameter:4.1” (10.4 cm) installed in the B501 base 6.1” (15.5 cm) installed in the B210LP base Shipping Weight:5.2 oz. (147 g) Operating Temperature: ASD-PL2F: 32° F to 120° F (0° C to 49° C) ASD-PTL2F: 32° F to 100° F (0° C to 38° C) UL®-Listed Velocity Range: 0-4000 ft./min. (1,219.2 m/min.), suitable for installation in ducts. Relative Humidity: 10-93% (non-condensing) Thermal Ratings:Fixed-temperature setpoint 135° F (57° C) Electrical Specifications Voltage Range: 15 – 32 volts DC peak Standby Current: (max. avg.): .0003 A @ 24 VDC (One communication every 5 seconds with LED blink enabled). Maximum Alarm- Current: .0065 A @ 24 VDC (LED) lit). Bases and Options B501 Plug-in sensor base without flange Dimensions:4.1” (10.4 cm) diameter B210LP Flanged mounting base Dimensions:6.1” (15.5 cm) diameter B210LPBP Flanged mounting base bulk pack Dimensions:6.1” (15.5 cm) diameter B224RB Relay Base Plug-in sensor base with auxiliary relay, SPDT, rated 2 amps @ 30 VDC (resistive). Screw terminals: Up to 14 AWG (2.0 mm2) 2 coil latching relay 1 Form C contact UL/CSA Rating: 0.9 A @ 125 VAC, inductive 0.9 A @ 110 VDC, inductive 3 A @ 30 VDC, resistive Dimensions:6.1” (15.5 cm) diameter Maximum: 25 devices between isolator bases. B200S Intelligent sensor sounder base Dimensions:6.875” (17.5 cm) diameter B200SR Standard sounder base, UL 8649th Edition compliant, ULC Listed Dimensions:6.875” (17.5 cm) diameter RA100Z Remote LED Annunciator BCK-200 Black detector covers (box of 10) DNR Duct smoke housing GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2011 by Honeywell International Inc. All rights reserved.www.gamewell-fci.com 9020-0620 Rev. E page 1 of 2 Velociti® Series ATD-L2F, ATD-RL2F Addressable Thermal Sensor APPROVED FM 3023594 SIGNALING 7270-1703:0115S2332 MEAApproved 219-02-E Vol.VI An ISO 9001-2000 Company Description The Gamewell-FCI Velociti® Series, addressable plug-in thermal sensors with integral communication provide fea- tures that surpass conventional sensors. Point ID capabil- ity allows each sensor’s address to be set, providing exact locations for pinpointing alarm locations and for selective maintenance. ATD thermal sensors use an innovative thermistor sensing circuit to produce 135°F/57°C fixed- temperature (ATD-L2F). The ATD-RL2F provides a combi- nation 15°/minute rate-of-rise with 135° fixed thermal detection that is included in a low-profile package. The ATD-HL2F provides fixed high-temperature detection at 190°F/88°C. These thermal sensors provide cost-effective, addressable property protection in a variety of applica- tions. The Velociti® Series uses a communication protocol that substantially increases the speed of communication between the sensors and Gamewell-FCI analog address- able fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel’s microprocessor stops the group poll and identifies the single device with the status change. The net effect is response speed up to five times greater than earlier designs. Installation ATD plug-in sensors use a separate base to simplify instal- lation, service, and maintenance. A special tool allows maintenance personnel to plug-in and remove sensors without using a ladder. Mount the base on a box which is at least 1.5" (3.8 cm) deep. Suitable mounting base boxes include: •4.0" (10.2 cm) square box. •3.5" (8.9 cm) or 4.0" (10.2 cm) octagonal box. • Single-gang box (except relay or isolator base). • With B200S or B200SR base, mounted on a 4.0" (10.2 cm) octagonal or square box. • With B224RB or B224BI base, mounted on a 3.5" (8.9 cm) octagonal box, or a 4.0" (10.2 cm) octagonal or square box. NOTE: Because of the inherent supervision provided by the SLC, end-of-line resistors are not required. Wiring “T- taps” or branches are permitted for Style 4 (Class “B”) wiring. Velociti ® and E3 Series® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. ULC® is a registered trademark of Underwriters Laboratories Canada Inc. Features • Sleek, low-profile design • Visual rotary switch addressing • Built-in functional test switch activated by an external magnet • Bicolor LEDs flash green whenever the sensor is addressed, and light steadily red on alarm* • Optional relay, isolator, or sounder bases • Low standby current • Addressable communication • Stable communication technique with noise immunity • Optional remote, single-gang LED accessory (RA-100Z) • Suitable for installation in ducts Note: *Only the red LED is operative in panels that do not operate in Velociti® mode. ATD-L2F GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9020-0620 Rev. E page 2 of 2 www.gamewell-fci.com Specifications ATD-L2F/ATD-RL2F Dimensions:2.1" (5.3 cm) Height 4.1" (10.4 cm) diameter installed in the B501 base 6.1" (15.5 cm) diameter installed in the B210LP base Shipping Weight: 4.8 oz. (137 g) Operating Temperature: ATD-L2F or ATD-RL2F –4° F to 100° F (–20° C to 38°C) ATD-HL2 –4° F to 150°F (–20 C to 66°C) Sensor Spacing:UL® approved for 50 ft. (15.2 m) center to center FM approved for 25 x 25 ft. (7.6 x 7.6 m) spacing Relative Humidity: 10 – 93% (non-condensing) ATD-L2F Fixed-temperature setpoint 135°F (57°C) ATD-RL2F Combination 135° F fixed temperature and 15° F(8.3°c)/per minute rate-of-rise° ATD-HL2F Fixed-temperature setpoint 190°F (88°C) Electrical Specifications Voltage Range:15 - 32 Volts DC peak Standby Current:200 mA @ 24 VDC (without communication) (max. avg.).0003 A @ 24 VDC (one communication every 5 seconds with LED blink enabled) LED Current (max.).0065 A @ 24 VDC (LED lit) Specifications Bases and Options B501 Plug-in sensor base without flange Dimensions:4.1” (10.4 cm) diameter B210LP Flanged mounting base Dimensions:6.1” (15.5 cm) diameter B210LPBP Flanged mounting base bulk pack Dimensions:6.1” (15.5 cm) diameter B224RB Plug-in sensor base with auxiliary relay, SPDT 2 coil latching relay 1 Form C contact UL/ CSA Rating: 0.9 A @ 125 VAC (inductive) 0.9 @ 110 VDC (inductive) 3.A @ 30 VDC (resistive) Dimensions: 6.1” (15.5 cm) diameter B224BI Plug-in sensor isolator base for Style 7 operation Dimensions:6.1” (15.5 cm) diameter Maximum 25 devices between isolator bases B200S Intelligent sensor sounder base Dimensions:6.875” (17.5 cm) diameter B200SR Standard sounder base, UL 864 9th Edition compliant, ULC Listed Dimensions:6.875” (17.5 cm) diameter RA-100Z Remote LED Annunciator BCK-200 Black detector covers (box of 10) Ordering Information Part Number Description ATD-L2F Addressable thermal sensor, fixed, 135° F ATD-RL2F Addressable thermal sensor, combination fixed,135° F and 15°/minute rate-of-rise. ATD-HL2F Addressable thermal sensor, fixed, 190° F GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2013 by Honeywell International Inc. All rights reserved.www.gamewell-fci.com 9020-0616 Rev. E page 1 of 2 MS-7 Series Non-Coded, Manual Fire Alarm Stations APPROVED FM 3023594 SIGNALING 7150-1703:0119 7150-1703:0170 7150-1703:0109 S2465 MEAApproved 67-02-E Vol.VIII Description The Gamewell-FCI, MS-7 Series manual fire alarm sta- tions are available in a wide variety of configurations. The Stations comply with the Americans with Disabilities Act (ADA) 5-lb. maximum pull force requirement. Operating instructions and Braille text are engraved in the handle. All stations have a key lock/reset which is keyed alike with Gamewell-FCI fire alarm control panels and other manual fire alarm stations. MS-7AF Velociti Addressable Station The MS-7AF Velociti® Series addressable station is a dou- ble action station designed for installation in the signaling line circuit of Gamewell-FCI analog addressable control panels. Activation of the station causes its assigned address to register at the control panel. The door contains an LED which flashes green in normal condition and lights steady red when the station has been activated.* The sta- tion features screw terminals. MS-7ASF Velociti Addressable Station The MS-7ASF Velociti® Series addressable station is a single action station designed for installation in the signal- ing line circuit of Gamewell-FCI analog addressable con- trol panels. Activation of the station causes its assigned address to register at the control panel. The door contains an LED which flashes green in normal condition and lights steady red when the station has been activated.* The sta- tion features screw terminals. The Velociti® Series stations use a communication proto- col that substantially increases the speed of communica- tion between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel’s microprocessor stops the group poll and focuses on the single device. The net effect is response speed up to five times greater than earlier designs. MS-7 Double Action Station The MS-7 double action station is used with conventional fire alarm control panels. It features a set of single pole contacts and screw terminals for connection to an initiating circuit. Velociti® is a registered trademark of Honeywell International Inc. UL® is a registered trademark of Underwriter’s Laboratories Inc. LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. Features • Addressable stations compatible with all Gamewell-FCI analog addressable fire alarm controls • Conventional stations suitable for use with any UL ® Listed control panel • Both single and double action stations available • Tumbler lock for test and reset keyed alike with Gamewell-FCI controls • Surface or semi-flush mounting • Shock and vibration resistant • Stations (MS-7LOB) Listed for outdoor applications • Complies with ADA pull force requirements *Only the red LED is operative in panels that do not oper- ate in Velociti mode. MS-7 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9020-0616 Rev. E page 2 of 2 www.gamewell-fci.com MS-7S Single Action Station The MS-7S single action station is used with conventional fire alarm control panels. It features a set of single pole contacts and wire leads for connection to an initiating circuit. MS-7SP Double Action Station The MS-7SP is a double action station similar to the MS-7 station, with the additional feature of both English and Spanish instructions molded into the unit. MS-7LR Dual-action Agent Release Station The MS-7LR is designed for use with the Gamewell-FCI fire alarm control panels with releasing capabilities and Flex Series releasing systems. It features a set of single pole contacts and screw terminals for connection to an ini- tiating circuit. MS-7LRA Agent Release Station with Abort The MS-7LRA is designed for use with the Gamewell-FCI fire alarm control panels with releasing capabilities and Flex Series releasing systems where system abort capabil- ities are required. It consists of an MS-7LR mounted on a plate with an abort switch and LED indicators for system normal, and system activated status. MS-7LOB Double Action Station (Listed for Outdoor Applications) The MS-7LOB station must be mounted on a Model SB-I/O backbox. In retrofit applications, the station is UL Listed for use with the WP-10 backbox. It is intended for use with conventional control panels and has a set of single pole contacts and screw terminals. Mounting The MS-7 interior stations may be surface mounted or semi-flush mounted on a standard double-gang, or 4-inch (10.2 cm) square electrical box. An optional trim ring (BG12TR) may also be used for semi-flush mounting. NYC-Plate The NYC-Plate provides the backplate for the manual pull station. (See Figure 1). Figure 1 NYC-Plate Specifications Material:Lexan® Contact Ratings:0.25 amps. @ 30 VAC/VDC (resistive) Dimensions:5 5/8” H x 4 1/4” W x 1 1/4” D (14 x 10.1 x 3.2 cm) Operating Temperature (MS-7AF, MS-7ASF):32° to 120° F (0° to 49° C) (MS-7LOB):-30° to 150° F (-35° to 66° C) Relative Humidity (MS-7AF, MS-7ASF):10 to 93% (non-condensing) (MS-7LOB):85% ± 5% @ 86° ± 3.6° (30° ± 2° C) Alarm Current:.0030 amp. 0.007 for LED Supervisory Current (MS-7AF, MS-7ASF):.00030 amps. Ordering Information Part Number Description MS-7 Double action station MS-7AF**Velociti addressable double action station MS-7ASF**Velociti addressable single action station MS-7S Single action station, wire leads MS-7SP Double action station, English and Spanish instructions MS-7LR Agent release station, dual-action MS-7LRA Agent release station with abort switch, LED indicators, dual- action MS-7LOB Double action station, outdoor use (Includes SB-I/O - Indoor/outdoor use backbox) SB-I/O Indoor/outdoor use backbackbox SB-10 Surface backbox BG12TR Trim ring for semi-flush mount, plastic NY-PLATE NYC backplate for manual pull station **For use with the Gamewell-FCI analog addressable control panels only. Agency Listings Features • Electrically compatible with existing SpectrAlert products • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Plug-in design • Field selectable candela settings on wall and ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185 • Same mounting plate for wall- and ceiling-mount units • Shorting spring on mounting plate for continuity check before installation • Tamper resistant construction • Outdoor wall and ceiling products rated from –40°F to 151°F • Design allows minimal intrusion into the back box • Horn rated at 88+ dbA at 16 volts • Rotary switch for horn tone and three volume selections • Outdoor products UL listed to UL 1638 (strobe) and UL 464 (horn) outdoor requirements • Outdoor products NEMA 4X rated • Compatible with MDL sync module The SpectrAlert Advance series of notification appliances is designed to simplify installations, with features such as plug in designs, instant feedback messages to ensure correct installation of individual devices, and 11 field-selectable candela settings for wall and ceiling strobes and horn/strobes. When installing Advance products, first attach a universal mounting plate to a four-inch square, four-inch octagon or double-gang junction box. The two-wire mounting plate attaches to a single-gang junction box. Next, connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate. Finally, attach the horn, strobe or horn/strobe to the mounting plate by inserting the product’s tabs in the mounting plate’s grooves. The device will rotate into position, locking the product’s pins into the mounting plate’s terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. The SpectrAlert Advance series includes outdoor notification appliances. Outdoor strobes and horn/strobes (two wire and four wire) are available for wall or ceiling. Outdoor horns are available for wall only. All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or dry applications. Selectable Output Horns, Strobes, and Horn/Strobes SpectrAlert® Advance selectable-output horns, strobes, and horn/strobes are rich with features guaranteed to cut installation times and maximize profits. MEA452-05-E3023572 7125-1653:186 (indoor strobes) 7300-1653:187 (outdoor strobes) 7125-1653:188 (horn/strobes, chime/strobes) 7135-1653:189 (horns, chimes) S4011 S5512 S3593 A05-0395-005 SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance horns, strobes and horn/strobes shall mount to a standard 4 × 4 × 1½-inch back box, 4-inch octagon back box or double-gang back box. Two-wire products shall also mount to a single-gang 2 × 4 × 17⁄8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full-wave rectified, unfiltered power supply. Strobes and horn/strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination The horn/strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn/strobe models shall operate on a coded or non-coded power supply. Outdoor Products SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit. The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three-fourths inch conduit entries. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn/strobe models over a single pair of wires. The module shall mount to a 411⁄16 × 411⁄16 × 21⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) K Series Operating Temperature –40°F to 151°F (–40°C to 66°C) Humidity Range 10 to 93% non-condensing (indoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12V nominal) or 16 to 33 V (24 nominal) Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions (including lens)6.8˝ diameter × 2.5˝ high (173 mm diameter × 64 mm high) Wall mount dimensions (including lens)5.6˝L × 4.7˝W × 2.5˝D (142 mm L × 119 mm W × 64 mm D) Horn dimensions 5.6˝L × 4.7˝W × 1.3˝D (142 mm L × 119 mm W × 33 mm D) Wall-mount back box skirt dimensions (BBS-2, BBSW-2)5.9˝L × 5.0˝W × 2.2˝D (151 mm L × 128 mm W × 56 mm D) Ceiling-mount back box skirt dimensions (BBSC-2, BBSCW-2)7.1˝ diameter × 2.25˝ high (180 mm diameter × 57 mm high) Wall-mount weatherproof back box dimensions (SA-WBB)5.7˝L × 5.1˝W × 2.0˝D (145 mm L × 130 mm W × 51 mm D) Ceiling-mount weatherproof back box dimensions (SA-WBBC)7.1˝ diameter × 2.0˝ high (180 mm diameter × 51 mm high) Wall-mount trim ring dimensions (TR-HS, TRW-HS)5.7˝L × 4.812˝W × 0.35˝D (146 mm L × 122 W mm × 9 D mm) Ceiling-mount trim ring dimensions (TRC-HS, TRCW-HS)6.9˝ diameter × 0.35 high (176 mm diameter × 9 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. A05-0395-005 Horn and Horn/Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts 24 Volt Nominal Reverberant Anechoic DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-temporal High 82 82 88 88 93 92 100 100 5 Non-temporal Medium 78 78 85 85 90 90 98 98 6 Non-temporal Low 75 75 81 81 88 84 96 92 7†Coded High 82 82 88 88 93 92 101 101 8†Coded Medium 78 78 85 85 90 90 97 98 9†Coded Low 75 75 81 81 88 85 96 92 †Settings 7, 8, and 9 are not available on 2-wire horn/strobe. UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC FWR DC FWR Standard Candela Range 15*123 128 66 71 15/75*142 148 77 81 30*NA NA 94 96 75*NA NA 158 153 95*NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High Candela Range 135 NA NA 228 207 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2-wire Horn/Strobe, Standard Candela Range (15–115 cd) DC Input 8–17.5 Volts 16–33 Volts 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-temporal High 141 152 91 100 116 176 201 221 229 Non-temporal Medium 133 145 75 85 102 163 187 207 216 Non-temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-temporal High 142 161 103 112 126 181 203 221 229 Non-temporal Medium 134 155 85 95 110 166 189 208 216 Non-temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Horn Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-temporal High 57 56 69 75 Non-temporal Medium 42 50 60 69 Non-temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 UL Current Draw Data Horn Tones and Sound Output Data UL Max. Current Draw (mA RMS), 2-wire Horn/Strobe, High Candela Range (135–185 cd) DC Input 16–33 Volts FWR Input 16–33 Volts 135 150 177 185 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-temporal High 255 270 303 309 Non-temporal High 233 248 275 281 Non-temporal Medium 242 259 293 299 Non-temporal Medium 219 232 262 267 Non-temporal Low 238 254 291 295 Non-temporal Low 214 229 256 262 Candela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Strobe Output (cd) Listed Candela Candela rating at –40°F 15 Do not use below 32°F15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2008 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. A05-0395-005 • 8/08 • #2018 SpectrAlert Advance Dimensions Model Description Wall Horn/Strobes P2R*†2-wire Horn/Strobe, Standard cd‡, Red P2RH*2-wire Horn/Strobe, High cd, Red P2RK*¤2-wire Horn/Strobe, Standard cd, Red, Outdoor P2RHK¤2-wire Horn/Strobe, High cd, Red, Outdoor P2W*2-wire Horn/Strobe, Standard cd, White P2WH*2-wire Horn/Strobe, High cd, White P4R*4-wire Horn/Strobe, Standard cd, Red P4RH*4-wire Horn/Strobe, High cd, Red P4RK¤4-wire Horn/Strobe, Standard cd, Red, Outdoor P4RHK¤4-wire Horn/Strobe, High cd, Red, Outdoor P4W*4-wire Horn/Strobe, Standard cd, White P4WH*4-wire Horn/Strobe, High cd, White Wall Strobes SR*†Strobe, Standard cd, Red SRH*†Strobe, High cd, Red SRK¤Strobe, Standard cd, Red, Outdoor SRHK Strobe, High cd, Red, Outdoor SW*Strobe, Standard cd, White SWH*Strobe, High cd, White Ceiling Horn/Strobes PC2R*2-wire Horn/Strobe, Standard cd, Red PC2RH*2-wire Horn/Strobe, High cd, Red PC2RK¤2-wire Horn/Strobe, Standard cd, Red, Outdoor PC2RHK¤2-wire Horn/Strobe, High cd, Red, Outdoor PC2W*†2-wire Horn/Strobe, Standard cd, White PC2WH*†2-wire Horn/Strobe, High cd, White PC4R 4-wire Horn/Strobe, Standard cd, Red PC4RH 4-wire Horn/Strobe, High cd, Red PC4RK 4-wire Horn/Strobe, Standard cd, Red, Outdoor PC4RHK¤4-wire Horn/Strobe, High cd, Red, Outdoor Model Description Ceiling Horn/Strobes (cont’d.) PC4W 4-wire Horn/Strobe, Standard cd, White PC4WH 4-wire Horn/Strobe, High cd, White Ceiling Strobes SCR*Strobe, Standard cd, Red SCRH*Strobe, High cd, Red SCRK¤Strobe, Standard cd, Red, Outdoor SCRHK¤Strobe, High cd, Red, Outdoor SCW*†Strobe, Standard cd, White SCWH*†Strobe, High cd, White Horns HR Horn, Red HRK¤ Horn, Red, Outdoor HW Horn, White Accessories BBS-2 Back Box Skirt, Wall, Red BBSW-2 Back Box Skirt, Wall, White BBSC-2 Back Box Skirt, Ceiling, Red BBSCW-2 Back Box Skirt, Ceiling, White TR-HS Trim Ring, Wall, Red TRW-HS Trim Ring, Wall White TRC-HS Trim Ring, Ceiling, Red TRCW-HS Trim Ring, Ceiling, White SpectrAlert Advance Ordering Information Notes: * Add “-P” to model number for plain housing (no “FIRE” marking on cover), e.g., P2R-P. † Add “-SP” to model number for “FUEGO” marking on cover, e.g., P2R-SP. ‡ “Standard cd,” refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. “High cd,” refers to strobes that include 135, 150, 177, and 185 candela settings. All outdoor units ending in “K” include a weatherproof back box. ¤ Add “-R” to model number for weatherproof replacement device (no back box included). 4.7˝ 5.6˝ 6.8˝ Dia. 2.5˝ 2.5˝ 2.23˝5.05˝ 5.98˝ 7.1˝ Dia. 2.25˝ 5.1˝ 2.0˝ 6.2˝ 7.1˝ Dia. 2.0˝ Wall-mount horn/strobes Ceiling-mount horn/strobes Wall back box skirt Wall weatherproof back boxCeiling back box skirt Ceiling weatherproof back box GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2010 by Honeywell International Inc. All rights reserved.www.gamewell-fci.com 9021-60521 Rev. B page 1 of 2 HPFF8 NAC Expander/Power SupplyDescription The Gamewell-FCI, HPFF8 is a Notification Appliance Cir- cuit (NAC) expansion panel designed to extend the power capabilities of existing NACs and provide power for the auxiliary devices. The HPFF8 connects to any 12 or 24V Fire Alarm Control Panel (FACP) or stand alone. The HPFF8 is available in 8.0 amps. It provides regulated and filtered 24VDC power to each of the four NACs and an auxiliary output. The NAC outputs are rated at 3.0 amps each (the total output cannot exceed 8.0 amps). The auxil- iary output is rated at 2.0 amps. This output is continuously supplied, even in alarm, and therefore must be taken into account for power supply loading and battery size calcula- tions. The NAC outputs may be configured as any of the follow- ing: • Four Class B (Style Y) • Two Class A (Style Z) • Two Class B and one Class A • Four Class A with the optional HPP31076 Class A adapter installed These power supplies contain an internal Battery charger capable of charging up to 26.0 amp-hour (AH) batteries. The HPFF8 is mounted in lockable wall cabinet units that can accommodate up to two (2), 18AH batteries. A multi- pack option allows for up to four chassis mount units installed in a single lockable SBB-D4 enclosure. These chassis mount units have a "CM" suffix, HPFF8CM and can accommodate two 12AH batteries. Power supplies are available in either 120VAC/60 Hz or 240VAC/50 Hz. One of the most challenging aspects of a retrofit applica- tion is locating the existing End-of-Line (EOL) resistor. In these applications that have EOL values, other than the 3.9k normally used with the HPFF8, a single resistor matching the existing EOL can be used as a reference for all the outputs. This feature speeds the installation and the system checkout, because the actual EOL does not need to be located and changed in the circuit. The reference resistor must be within the range of 1.9k to 25k. Features • Four (4) supervised notification application circuits (NACs) capable of supplying +24VDC at 3.0 amp maximum each • NAC output circuits may be configured as any of the following: - Four Class B (Style Y) - Two Class B & one Class A - Two Class A (Style Z) - Four Class A with the optional HPP31076 Class A adapter installed • Four field-programmable operational modes • 2.0 amp auxiliary continuously supplied output • Two (2) fully supervised input/output control circuits • Temporal coding and sync protocols compatible with the following notification appliance brands: - System Sensor - Faraday - Gamewell - Amseco - Cooper-Wheelock - Gentex • Supervised AC input, battery voltage, auxiliary output, charger, and earth ground faults • Trouble indication for supervision of the following: - NAC circuits - Auxiliary output - AC input - Charger - Battery voltage - Open contacts in the initiat- ing device signal inputs (for FACP trouble notification) - Earth ground faults by individual status LED's • Separate Trouble and AC Fail Form-C relay Contacts HPFF8 An ISO 9001-2000 Company 7315-1637:0102 SIGNALING S24562 FM APPROVED GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60521 Rev. B page 2 of 2 www.gamewell-fci.com Features (Continued) • The Trouble Form-C relay contacts selectable for imme- diate or a 2 hour delay with AC failure • 26 AH battery charger capability; the wall cabinet supports two 12V 18AH batteries, while the multi-pack equipment cabinets supports two 12V 12AH batteries. • NAC Overload protection and indication • Up to four chassis mount units (HPFF8CM) can be installed in the SBB-D4 backbox • Wall mount units can be configured to internally house the following: - one AOM-2SF single control module - one AOM-2R single relay module Specifications Primary Input Power:120VAC/60Hz, 3.6A or 220VAC/50Hz, 1.5A Secondary Power:24 volt operation: two (2), 7-24 AH batteries Battery Charging Capacity:Up to 26 AH batteries mounted Battery Space: HPFF8 Cabinet:Up to two 18AH batteries SBB-D4 Cabinet:Up to two 12AH batteries per supply Total Output Power:8.0A max Standby Current: 0.030 A Auxiliary Power Output:0.15A under all conditions 2.0A if load is removed dur- ing operation (external relay or AC Fail Relay is required) Specifications (Continued) NAC Output Ratings:24VDC fully regulated, 3.0A max per circuit (8.0A total) End-of-Line Resistor Range: 2K to 25k ohm, ½ watt Common Trouble Relay/AC Fail Relay:2.0A at 28VDC or 120VAC Input Control Circuit:16-30VDC @ 5mA min. Temperature Rating:32°F to 120°F (0°C to 49°C Relative Humidity:10% to 93% non-condensing Cabinet Dimensions: HPFF8 Cabinet:16.65” W x 19.0” H x 5.2” D (42.29 W x 48.26 H 13.23 D cm) SBB-D4 Cabinet:24” W x 45.9” H x 5.15” D (60.96 W x 116.52 H x 13.1D cm) Ordering Information Part Number Description HPFF8 8A fire rated power supply operating at 120VAC/60 Hz. Unit includes red enclosure with HPP lock and key HPFF8CM 8A fire rated power supply - chassis mounted operating at 120VAC/60 Hz. Unit includes mounting hardware for installation in the SBB-D4 enclosure HPFF8E 8A fire rated power supply operating at 240VAC/50 Hz HPFF8CME 8A fire rated power supply chassis mounted operating at 240VAC/50 Hz HPP31076 Class A (Style Z) NAC module FCI-VDR-D4 Vented door, PK-625 lock and key for SBB-D4 backbox, black SBB-D4 Backbox, accepts up to 4 chassis, black Standby 0.075 A Alarm 1.338 A Qty Draw Non-Alarm Qty Draw Alarm 1 x 0.07500 0.07500 1 x 0.20600 0.20600 1 x 0.00000 0.00000 1 x 0.11600 0.11600 1 x 0.00000 0.00000 1 x 0.09100 0.09100 3 x 0.00000 0.00000 3 x 0.11600 0.34800 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 0.55500 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 0.00000 1 x 0.00000 0.00000 1 x 0.09100 0.09100 2 x 0.00000 0.00000 2 x 0.11600 0.23200 1 x 0.00000 0.00000 1 x 0.06600 0.06600 2 x 0.00000 0.00000 2 x 0.09400 0.18800 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 0.57700 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 0.00000 0 x 0.00000 0 x 0.03000 0 x 0.03700 0 x 0.00850 0 x 0.00400 0 x 0.00650 0 x 0.05000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC #3 Totals (Max 3 Amps): 4. . P2W30 PC2W15 PC2W30 PC2W30 SCW15 NAC #2 Totals (Max 3 Amps): Device 1.338 System Current Draw - HPFF8 Tie to Existing Lvl 1 Total Current Secondary Alarm CurrentSecondary Non-Alarm Current 1. System Modules 1. HS-1 HPFF8 Main Circuit Board Other compatible devices Other compatible devices Total Non-Alarm Load: 2. . NAC #1 Totals (Max 3 Amps): NAC #4 Totals (Max 3 Amps): 3. HS-2 PC2W15 TB4 Totals (Max 2 Amps): SCW30 Other compatible devices 7. Compatible Devices not listed 0.075 6. Auxiliary Power PR-3 FIRERAY5000 EVM E3SMRCO/E3SA Auxiliary Device Total Alarm Load: Protected Premises:Date:3/9/2017 Address: City:State:Idaho Zip:83460 Prepared By:Phone:801.468.8300 Address:Email: City:State:UT Zip:84115 Secondary Load Requirements 2.29 Amp Hours Total (AH) 1.80 0.11 1.91 x 1.2 2.29 AH 8 Amp Hours TRUE Current Draw Secondary Standby Load Select batteries from the list below. Battery Selection 8.0 AH BAT-1270 Battery (12 volt) Derating factor Secondary Load Requirements Total Secondary Load Secondary Alarm Load x1.338 A Required Alarm Time (hours) 0.084 hours Time (hours) Required Standby Time 24 hoursx Total Secondary Load from the calculation table below. 0.075 A 1481 S Major Street Office@nelsonfire.com Salt Lake City Secondary Power Requirements Clarke Building Lvls 1 & 3 BYU-Idaho 525 South Center Street Rexburg Nelson Fire Systems HPFF8 Power Supply Page 2 of 131 Battery Distribution Chart Comments 5.71 2.16 0.13 3. The selected batteries (8AH) are within the charger range of this power supply (7-26AH). Spare Battery Capacity Secondary Standby Load 2. Selected battery size meets secondary load requirements. Battery Selection (AH) - Secondary Load Requirements (AH) Secondary Standby Load (AH) * Derating Factor 1. Batteries will fit in the FACP cabinet. Secondary Alarm Load (AH) * Derating FactorSecondary Alarm Load Shows amp-hour distribution of your selections. Spare Battery Capacity 71% Secondary Standby Load 27% Secondary Alarm Load 2% Spare Battery Capacity Secondary Standby Load Secondary Alarm Load Page 3 of 131 Standby 0.075 A Alarm 0.620 A Qty Draw Non-Alarm Qty Draw Alarm 1 x 0.07500 0.07500 1 x 0.20600 0.20600 1 x 0.00000 0.00000 1 x 0.06600 0.06600 3 x 0.00000 0.00000 3 x 0.11600 0.34800 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 0.41400 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 0.00000 0 x 0.00000 0 x 0.03000 0 x 0.03700 0 x 0.00850 0 x 0.00400 0 x 0.00650 0 x 0.05000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.00000 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 NAC #3 Totals (Max 3 Amps): 4. . SW15 PC2W30 NAC #2 Totals (Max 3 Amps): Device 0.620 System Current Draw - HPFF8 Tie to Existing Lvl 3 Total Current Secondary Alarm CurrentSecondary Non-Alarm Current 1. System Modules 1. HS-3 HPFF8 Main Circuit Board Other compatible devices Other compatible devices Total Non-Alarm Load: 2. . NAC #1 Totals (Max 3 Amps): NAC #4 Totals (Max 3 Amps): 3. . TB4 Totals (Max 2 Amps): Other compatible devices 7. Compatible Devices not listed 0.075 6. Auxiliary Power PR-3 FIRERAY5000 EVM E3SMRCO/E3SA Auxiliary Device Total Alarm Load: Job Name: Remodel Lvls 1 & 3 Clarke Building 525 South Center Street Rexburg , ID 83460 AHJ: BYU-Idaho Prepared By: Nelson Fire Systems 1481 S. Major Street SLC, UT 84115 Circuit Information Panel Name: Existing FF8 Level 1 Circuit Name: HS-1 Starting Voltage: Starting Voltage = 20.4 (1.5) amp circuit Class B @ 14 AWG DC 24 - volt Supply Horn/Strobe PC2W 15 0.066 Temporal, Low 95 95 20.233 20.135 19.977 19.728 Horn/Strobe PC2W 30 0.093 Temporal, Low 40 135 20.173 20.040 19.826 19.487 Horn/Strobe PC2W 30 0.093 Temporal, Low 30 165 20.139 19.986 19.741 19.352 Horn/Strobe PC2W 30 0.093 Temporal, Low 30 195 20.117 19.951 19.684 19.262 Horn/Strobe P2W 30 0.093 Temporal, Low 20 215 20.109 19.939 19.665 19.232 Type and Model Candela Current (Amps) Tone and Volume Dist from last device Dist from source (ft) 12 14 16 18 Total current/amps 0.438 Total Dist:215 voltage drop 0.291 0.461 0.735 1.168 3/9/2017 1 Circuit Information Panel Name: Existing FF8 Level 1 Circuit Name: HS-2 Starting Voltage: Starting Voltage = 20.4 (1.5) amp circuit Class B @ 14 AWG DC 24 - volt Supply Horn/Strobe PC2W 30 0.093 Temporal, Low 35 85 20.240 20.147 19.996 19.758 Strobe SCW 30 0.094 35 120 20.195 20.075 19.883 19.578 Horn/Strobe PC2W 15 0.066 Temporal, Low 25 145 20.173 20.039 19.826 19.487 Strobe SCW 15 0.066 20 165 20.160 20.019 19.794 19.435 Horn/Strobe PC2W 0.093 Temporal, Low 30 195 20.149 20.001 19.765 19.390 Strobe SCW 30 0.094 50 50 20.298 20.239 20.143 19.991 30 Type and Model Candela Current (Amps) Tone and Volume Dist from last device Dist from source (ft) 12 14 16 18 Total current/amps 0.506 Total Dist:195 voltage drop 0.251 0.399 0.635 1.010 3/9/2017 2 Circuit Information Panel Name: Existing FF8 Level 3 Circuit Name: HS-3 Starting Voltage: Starting Voltage = 20.4 (1.5) amp circuit Class B @ 14 AWG DC 24 - volt Supply Horn/Strobe PC2W 30 0.093 Temporal, Low 40 155 20.224 20.120 19.954 19.691 Horn/Strobe PC2W 30 0.093 Temporal, Low 45 200 20.207 20.093 19.912 19.624 Strobe SW 15 0.066 35 115 20.254 20.168 20.030 19.811 Horn/Strobe PC2W 30 0.093 Temporal, Low 80 80 20.289 20.224 20.120 19.954 Type and Model Candela Current (Amps) Tone and Volume Dist from last device Dist from source (ft) 12 14 16 18 Total current/amps 0.345 Total Dist:200 voltage drop 0.193 0.307 0.488 0.776 3/9/2017 3