HomeMy WebLinkAboutRESCHECK - 17-00086 - 300 Baldwin Dr - SFRREScheck Software Version 4.6.2 Compliance Certificate Lvi Project FS6B8 - PRINCETON Energy Code: 2012 IECC 50.0 Location: Rexburg, Idaho 30 Construction Type: Single-family 22.0 Project Type: New Construction 14 Orientation: Bldg. faces 90 deg. from North Conditioned Floor Area: 2,621 ft2 Glazing Area 10% Climate Zone: 6 (8693 HDD) 24 Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: FOUNDER SQUARE SUED. BLOCK -8, Kartchner Homes LOT: 6 Orientation: Right side Logan, UT Resburg, ID 83440 john@kartchnerhomes.com Compliance: Passes using UA trade-off Compliance: 1.6% Better Than Code Maximum UA: 307 Your UA: 302 The % Better or Worse Than Code Index reflects how close to compliance the house Is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home. Envelope Assemblies Ceiling 1: Flat Ceiling or Scissor Truss 1,136 50.0 0.0 0.026 30 Second Level - Front: Wood Frame, 16" o.c. 320 22.0 0.0 0.056 14 Orientation: Front Window 1: Wood Frame:Double Pane with Low -E 75 0.320 24 Orientation: Front Second Level - Right: Wood Frame, 16" D.C. 232 22.0 0.0 0.056 13 Orientation: Right side Second Level Rear: Wood Frame, 16" D.C. 304 22.0 0.0 0.056 14 Orientation: Back Window 1: Wood Frame:Double Pane with Low -E 50 0.320 16 Orientation: Back Seocnd Level - Left: Wood Frame, 16" D.C. 232 21.0 0.0 0.057 13 Orientation: Left side Floor 2: All -Wood Joist/Truss:Over Unconditioned Space 380 30.0 0.0 0.033 13 Main Level - Front: Wood Frame, 16" o.c. 489 22.0 0.0 0.056 22 Orientation: Front Window 1: Wood Frame:Double Pane with Low -E 30 0.320 10 Orientation: Front Door 1: Solid 75 0.150 11 Orientation: Front Main Level - Right: Wood Frame, 16" D.C. 108 22.0 0.0 0.056 6 Orientation: Right side Project Title: FS6B8 - PRINCETON Report date: 02/27/17 Data filename: C:\Users\jhoel lei n.MAI N\Documents\REScheck\FS6B8 - Princeton.rck Page 1 of 9 Main Level - Rear: Wood Frame, 16" o.c. 378 22.0 0.0 0.056 18 Orientation: Back Window 1: Wood Frame:Double Pane with Low -E 54 0.320 17 Orientation: Back Main Level - Right: Wood Frame, 16" o.c. 434 22.0 0.0 0.056 24 Orientation: Left side Basement Wall 1: Solid Concrete or Masonry 434 0.0 15.0 0.042 18 Orientation: Front Wall height: 8.0' Depth below grade: 8.0' Insulation depth: 8.0' Basement Wall 2: Solid Concrete or Masonry 96 0.0 15.0 0.042 2 Orientation: Right side Wall height: 8.0' Depth below grade: 8.0' Insulation depth: 8.0' Window 6: Vinyl/Fiberglass Frame:Double Pane with Low -E 40 0.320 13 Orientation: Right side Basement Wall 3: Solid Concrete or Masonry 336 0.0 15.0 0.042 14 Orientation: Back Wall height: 8.0' Depth below grade: 8.0' Insulation depth: 8.0' Basement Wall 4: Solid Concrete or Masonry 232 0.0 15.0 0.042 10 Orientation: Left side Wall height: 8.0' Depth below grade: 8.0' Insulation depth: 8.0' Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in REScheck Version 4.6.2 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. me -Title Signature Project Title: FS6B8 - PRINCETON Report date: 02/27/17 Data filename: C:\Users\jhoellein.MAIN\Documents\REScheck\FS688 - Princeton.rck Page 2 of 9 1ZREScheck Software Version 4.6.2 Inspection Checklist Energy Code: 2012 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Pre-Inspection/Plan Review Plans Verified I Value Field Verified Value Complies? Comments/Assumptions & Req.ID 103.1, ;Construction drawings and❑Complies 103.2 (documentation demonstrate -❑Does Not [PR111 ;energy code compliance for the ;building envelope.❑Not Observable ❑Not Applicable 103.1, ;Construction drawings and❑Complies 103.2, (documentation demonstrate❑Does Not 403.7 :energy code compliance for - [PR3]1 I lighting and mechanical systems. '.. !❑Not Observable D S(Systems serving multiple ❑Not Applicable ;dwelling units must demonstrate (compliance with the IECC (Commercial Provisions. 302.1, !,Heating and cooling equipment is: Heating: ! Heating: ❑Complies 403.6 :sized per ACCA Manual 5 based Btu/hr Btu/hr❑Does Not [PR2]2..;,'_ 'J 'JA on loads calculated per ACCA Manual J or other methods❑Not ;Cooling: 1 Cooling: Observable by the code official. Btu/hr ;Btu/hr_ I❑Not Applicable j Additional Comments/Assumptions: 1 High Impact (Tier 1) a Medium Impact (Tier 2) F3 Low Impact (Tier 3) Project Title: FS668 - PRINCETON Report date: 02/27/17 Data filename: C:\Users\jhoellein.MAIN\Documents\REScheck\FS6B8 - Princeton.rck Page 3 of 9 Section # Foundation Inspection I Plans Verified Value Field Verified Value Complies? Comments/Assumptions & Req.ID 402.1.1 ;Conditioned basement wall ; R- R-❑Complies See the Envelope Assemblies [F0411 :insulation R-value. Where interior; R_ R_❑Does Not ',table for values. ;insulation is used, verification — : may need to occur during Observable :Insulation Inspection. Not❑Not Applicable :required in warm-humid locations; :in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies [F0511 :insulation installed per -❑Does Not :manufacturer's instructions. ❑Not Observable ' -.;❑Not Applicable 402.2.8 :Conditioned basement wall I ft —ft ❑Complies ;See the Envelope Assemblies [F0611 ;insulation depth of burial or❑Does Not ;table for values. !distance from top of wall. j❑Not Observable j❑Not Applicable 303.2 .1 A protective covering is installed❑Complies 'Comp" [F011]1 Ito protect exposed exterior Not i ! insulation and extends a + minimum of 6 in. below grade. ,` 1 i❑Not Observable ❑Not Applicable 403.8 'Snow-and ice-melting system JOComplies [FO12]2 controls installed.< '❑Does Not J RMO- ❑Not Observable ❑Not Applicable j Additional Comments/Assumptions: 1 I High Impact (Tier 1) IMIMedium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: FS6B8 - PRINCETON Report date: 02/27/17 Data filename: C:\Users\jhoel lei n.MAI N\Documents\REScheck\F56B8 - Princeton,rck Page 4 of 9 Section # Framing /Rough -In Inspection Plans Verified Field Verified Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, ;Door U -factor. U-_ U-_ ;❑Complies ! See the Envelope Assemblies 402.3.4❑Does Not ;table for values. [FRl]1 ;❑Not Observable ❑Not Applicable 402.1.1, ;Glazing U-factor(area-weighted U- U- -] ;see the Envelope Assemblies 402.3.1, !average).❑Does Not table for values. 402.3.3, 402.3.6, ;❑Not Observable 402.5❑Not Applicable [FR2]1 303.1.3 U -factors of fenestration products 0 -'. ❑Complies [FR411 :are determined in accordance s "❑Does Not :with the NFRC test procedure or "❑Not ;taken from the default table. Observable ❑Not Applicable 402.4.1.1 ,Air barrier and thermal barrier ❑Complies [FR23]1 :installed per manufacturers ❑Does Not j instructions. _ ❑Not Observable _x ❑Not Applicable 402.4.3 ' Fenestration that is not site built - .. ❑Complies [FR20]1 'is listed and labeled as meeting; lAAMA /WDMA/CSA 101/I.S 2/A440 i t F'°- ❑Does Not •'3 K?,, 1 y - []Not Observable j or has infiltration rates per NFRC_ '' ❑Not 1400 that do not exceed code Applicable !limits. - >_ 402.4.4 iIC-rated recessed lighting fixtures-_" ❑Complies [FR16]2 : sealed at housing/interior finish i," ". _.� - ❑Does Not `� and labeled to indicate <_2.0 cfm- r• ❑Not Observable ;leakage at 75 Pa. ��r,- - - ❑Not Applicable A 403.2.1 ;Supply ducts in attics are ! R-_ R -_❑Complies [FR1211 I insulated to all -8. All other ducts 1R- 1 R_ ;❑Does Not :in unconditioned spaces or Observable ;outside the building envelope are;❑Not Applicable : insulated to alk -6. 403.2.2 :All joints and seams of air ducts, _ - ❑Complies [FR13]1 lair handlers, and filter boxes are _ ❑Does Not 0 !sealed. ,.. _ ❑Not Observable n ❑Not Applicable 403.2.3 Building cavities are not used as ❑Complies [FR15]3 :ducts or plenums." ❑Does Not U' 4 []Not Observable „„,.x ❑Not Applicable 403.3 :HVAC piping conveying fluids R-_ R-_ ;❑Complies [FR17]2 : above 105 OF or chilled fluids j❑Does Not below 55 OF are insulated to >_R- '.,3 ;❑Not Observable ❑Not Applicable 403.3.1 ;Protection of insulation on HVAC s" �`,�•''"� ❑Complies [FR24]1 (piping. -❑Does Not . ❑Not Observable ' ❑Not Applicable 403.4.2 ;Hot water pipes are insulated to R-_ R-_ ;❑Complies [FR18]' >R-3. :❑Does Not il❑Not Observable ❑Not Applicable 11 High Impact (Tier 1) j' Medium Impact (Tier 2) 13' Low Impact (Tier 3) Project Title: FS6B8 -PRINCETON Report date: 02/27/17 Data filename: C:\Users\jhoellein.MAIN\Documents\REScheck\FS6B8 - Princeton.rck Page 5 of 9 Section Plans Verified Field Verified # Framing /Rough -In Inspection & Req.ID Value Value Complies? Comments/Assumptions 403.5 . Automatic or gravity dampers arei, ❑Complies [FR1912 -installed on all outdoor air , r� a 1-; i;❑Does Not Intakes and exhausts. ' u'� �- :�. 7 . Lr €�� []Not Observable i y'❑Not Applicable Additional Comments/Assumptions: 111 High Impact (Tier 1) rAl Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: FS6B8 -PRINCETON Report date: 02/27/17 Data filename: C:\Users\jhoelIein.MAIN\Documents\REScheck\FS688 - Princeton.rck Page 6 of 9 Section # Insulation Inspection Plans Verified Value Field Verified Value Compiles? Comments/Assumptions & Req.ID 303.1 :All installed insulation is labeled '.. ',❑Complies [IN or the installed R-values❑Does Not '-' provided. - I❑Not Observable j❑Not Applicable 402.1.1, Floor insulation R -value. R- R -_❑Complies ;See the Envelope Assemblies 402.2.6 ❑ Wood j ❑ Wood❑Does Not table for values. [IN1]1 ❑ Steel ❑ Steel ;❑Not Observable j❑Not Applicable 303.2, Floor insulation installed per ❑Complies 402.2.7 manufacturer's instructions, and ❑Does Not [IN2]1 in substantial contact with the _ ❑Not Observable IE]Not ;underside of the subfloor. Applicable 402.1.1, ; Wall insulation R -value. If this is a: R- R -❑Complies ;See the Envelope Assemblies 402.2.5, :mass wall with at least 1/2 of the I ❑ Wood ❑Wood ❑Does Not ;table for values. 402.2.6 :wall insulation on the wall I E] Mass j E] Mass ;❑Nat Observable [IN311 ;exterior, the exterior insulation requirement applies (FR10), ; ❑ Steel ❑ Steel 1` ;❑Not Applicable j 303.2 ;Wall insulation is installed per `;f❑Complies [IN411 ;manufacturer's instructions. , ❑Does Not �-❑Not Observable I ❑Not Applicable Additional Comments/Assumptions: 111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: FS6B8 - PRINCETON Report date: 02/27/17 Data filename: C:\Users\jhoellein.MAIN\Documents\REScheck\FS6B8 - Princeton.rck Page 7 of 9 Section # Final Inspection Provisions Plans Verified Field Verified Value Value Complies? Comments/Assumptions & Req. 402.1.1, ;Ceiling insulation R -value. R-_ R -❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood❑Does Not table for values. 402.2.2, 402.2.6 ❑ Steel ❑ Steel ;❑Not Observable [Fill'❑Not Applicable 303.1.1.1,:Ceiling insulation installed per=E]Not ❑Comples 303.2 !manufacturer's instructions.❑Does Not[FI211 ; Blown insulation marked every Observable ;300 ft'.❑Not ❑Not Applicable Vented attics with air permeable❑Complies ;insulation include baffle adjacent❑Does Not ,to soffit and eave vents that extends over insulation. ❑Not Observable Applicable 402.2.4 ;Attic access hatch and door R-_ R-_ ;❑Complies [F1311 :insulation >_R -value of the i;❑Does Not ;adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 =_ ACH 50 =_ ;❑Complies [FI17]1 :ach in Climate Zones 1-2, and j❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.2.2 ;Duct tightness test result of <=4 cfm/100 cfm/100 ;❑Complies [F1411 :cfm/100 ft2 across the system or TO ft'❑Does Not <=3 cfm/100 ft2 without air❑Not handler @ 25 Pa. For rough -in Observable ;tests, verification may need to ;❑Not Applicable occur during Framing Inspection. 403.2.2.1 ;Air handler leakage designated ❑Complies (FI24]1 :by manufacturer at <=2% of El Does Not ;design airflow. ❑Not Observable ❑Not Applicable 403.1.1 .,3 Programmable thermostats ` -❑Complies , [F19]2 installed on forced air furnaces. A;� ❑Does Not ; 14 AL a' ❑Not Observable ❑Not Applicable 403.112 cry, Heat pump thermostat installed - , ❑Complies [ on heat pumps. []Does Not #a��" []Not Observable - ❑Not Applicable 403.4.1 :Circulating service hot water -. ❑Complies [FIll12 'systems have automatic or ❑Does Not ,0j ;accessible manual controls. _ _ ,-❑Not Observable - - ` ❑Not Applicable 403.5.1 All mechanical ventilation system %,- -° ❑Complies [FI25]2 ;fans not part of tested and listed Ery- ❑Does Not HVAC equipment meet efficacy ;and air flow limits. ; - ❑Not Observable ❑Not Applicable 404.1 '175%of lamps in permanent ❑Complies [FI611 'fixtures or 75% of permanent '`• ❑Does Not 4J jfixtures have high efficacy lamps Does not apply to low -voltage <.e []Not Observable lighting. ❑Not Applicable 1 I High Impact (Tier 1) [,4"31 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: FS6138 - PRINCETON Report date: 02/27/17 Data filename: C:\Users\jhoellein.MAIN\Documents\REScheck\FS6B8 - Princeton.rck Page 8 of 9 Section # Final Inspection Provisions Plans Verified Field Verified Value Value Complies? Comments/Assumptions & Req.ID 404.1.1 :Fuel gas lighting systems have ,❑Complies [FI2313 no continuous pilot light. '!❑Does Not - ❑Not Observable �. ,I❑Not Applicable 401.3 !Compliance certificate posted. -: ❑Complies [FI7]2 ± 113Does Not _u '❑Not Observable .a❑Not Applicable 303.3 Manufacturer manuals for. ❑Complies [FI18]3 mechanical and water heating []Does Not 8; systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact (Tier 1) Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: FS6138 - PRINCETON Report date: 02/27/17 Data filename: C:\Users\jhoel lei n.MAI N\Documents\REScheck\FS6B8 - Princeton.rck Page 9 of S 0 �J(2012 IECC Energy Efficiency Certificate Above -Grade Wall 22.00 Below -Grade Wall 75.00 Floor 30.00 Ceiling / Roof 50.00 Ductwork (unconditioned spaces): Window 0.32 Door 0.15 Heating System: Cooling System: Water Heater: Name: Date: Comments