Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LOAD SHORT FORM - 17-00086 - 300 Baldwin Dr - SFR
9 Load Short Form Job: FS6B8 wri htsoft Date: 2121117 Entire House By: Vince Byrann Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 20&7457021 Fax: 208-745-7329 Email: highwuntryph@yahoo.com For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 HEATING EQUIPMENT Make Goodman Mfg. Design GOODMAN Model Htg Clg Infiltration Outside db CF) -6 89 Method Simplified Inside db (°F) 70 75 Construction quality Average Design TD (°F) 76 14 Fireplaces 0 Daily range - H 32 Inside humidity (%) 50 50 672 Moisture difference (gr/Ib) 62 -31 242 HEATING EQUIPMENT Make Goodman Mfg. Trade GOODMAN Model GMH950703BX AHRI ref 2002183 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 95 AFUE Goodman Mfg. 69000 Btuh 52440 Btuh 67 °F 850 cfm 0.024 cfm/Btuh 0.70 in H2O COOLING EQUIPMENT Make Goodman Mfg. Trade GOODMAN, JANITROL, AMANA DISTI... Cord GSX130241C' Coil Capf30301bx AHRI ref 4765510 Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 11.0 EER, 13 SEER 16100 Btuh 6900 Btuh 23000 Stun 850 cfm 0.113 cfm/Btuh 0.70 in H2O 1.00 116 ROOM NAME Area (ft2) Htg load (Btuh) Cig load (Btuh) Htg AVF (cfm) Clg AVF (cfm) Room1 604 9289 2238 226 252 Room2 116 1905 201 46 23 Room3 150 2075 282 50 32 Room4 250 3232 672 79 76 Rooms 242 2001 852 49 96 Room7 45 558 71 14 8 Room8 154 2163 458 53 52 Room9 120 2611 481 64 54 Room6 156 2569 857 62 97 Room10 441 4903 1319 119 149 Room11 321 3274 81 80 9 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017 -Feb -21 08:57:53 wrightsoft' Right -Suite® U niversal 2017 17.0.10 RSU20477 Page ...are\Kanchner\FS6B8 pdnceton with basement.mp Calc =MJ8 House faces: N Entire House d 2624 34948 7544 850 850 Other equip loads 3121 575 Equip. @ 0.94 RSM 7632 Latent cooling 0 TnTAIC .coo I een I o- -.1— c _ _. Ivia Vw VVV Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017 -Feb -21 08:57:53 WrlghtSOft' Right-Suite®Universal 201717.0.10RSU20477 Paget ...are\Kartchner\FS6B8 panceton with basement.mp Cale = MJ8 House faces: N Y + Wrightsoft BuildingAnalysis Job: FS6B8 Date: 2121117 Entire House By: Vince Byram Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-745-7329 Email: highcountryph@yahoo.com For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 ]esiarr Cnnditir Location: Btuh/ft2 Indoor: Heating Cooling Idaho Falls, ID, US 15150 Indoor temperature (°F) 70 75 Elevation: 4741 ft 15.5 Design TD (°F) 76 14 Latitude: 44°N Ceilings Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 61.5 -31.5 Dry bulb (°F) -6 89 Infiltration: Ducts Dailyrange (°F) - 34 ( H ) Method Simplified 0 Wetbulb(°F) - 60 Construction quality Average 0 Wind speed (mph) 15.0 7.5 Fireplaces 0 Adjustments Heating Component Btuh/ft2 Btuh %of load Walls 4.6 15150 39.8 Glazing 24.3 5894 15.5 Doors 11.4 472 1.2 Ceilings 1.5 1800 4.7 Floors 2.1 2492 6.5 Infiltration 3.3 9140 24.0 Ducts 0 0 Piping 0 0 Humidification 0 0 Ventilation 3121 8.2 Adjustments 0 Total 38069 100.0 Component Btuh/ft2 Btuh % of load Walls 0.3 1083 13.3 Glazing 18.4 4467 55.0 Doors 2.8 115 1.4 Ceilings 0.8 995 12.2 Floors 0.0 22 0.3 Infiltration 0.3 862 10.6 Ducts 0 0 Ventilation 575 7.1 Internal gains 0 0 Blower 0 0 Adjustments 0 Total 8119 100.0 Latent Cooling Load = 0 Btuh Overall U-value=0.055Btuh/fta-°F Data entries checked. WrIg htsoft• 2017 -Feb -2108:57:53 Righl-Sulte® Universal 201717.0.10 RSU20477 Pagel ...areftrtchnerTS6B8 pnncelon with basement.rup Calc=M.18 House faces: N + wrightsoft Component Constructions o 2/26B� Entire House By: Vince Byram Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-7457329 Email: highcounbyph@yahoo.mm For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 ]esirin Conditir. Location: 458 Indoor: Heating Cooling Idaho Falls, ID, US 0.47 Indoor temperature (°F) 70 75 Elevation: 4741 ft 21.0 Design TD (TF) 76 14 Latitude: 440N s Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 61.5 -31.5 Dry bulb (T) -6 89 Infiltration: 4.94 2757 Dailyrange (°F) - 34 (H ) Method Simplified 0.065 Wletbulbff) - 60 Construction quality Average 1016 Wind speed (mph) 15.0 7.5 Fireplaces 0 3.93 Construction descriptions Or Area IJ -value Insul R Htg HTM Loss Clg HTM Galin W BM/ft'-°F a'-°FIBWr Rohm Btuh eh"M Bluh Walls 12F-Osw: Frm wall, vnl ext, 3/8" wood shth, r-21 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood firm, 16" o.c. stud 151319-Owc-6: Bg wall, heavy dry or light damp soil, 2"x6" wood int firm, concrete wall, r-19 cav ins, 8" thk, 1/2" gypsum board int fnsh Partitions (none) Windows 61 C: 61 Q 6.67 fl head ht Doors metal: Door, mtl pur core type Ceilings 166-50ad: Attic ceiling, asphalt shingles roof mat, r-50 will ins, 1/2" gypsum board Int fnsh 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 cell ins, 5/8" gypsum board int fnsh Floors 20P -30c: Fir floor, frm fir, 12" thkns, carpet fir fnsh, r-30 cav Ins, gar ovr n 458 0.065 21.0 4.94 2260 0.47 217 e 585 0.065 21.0 4.94 2890 0.47 278 s 542 0.065 21.0 4.94 2676 0.47 257 w 558 0.065 21.0 4.94 2757 0.47 265 all 2142 0.065 21.0 4.94 10583 0.47 1016 n 333 0.043 19.0 3.93 1308 0.06 20 e 238 0.043 19.0 3.75 892 0.04 10 s 333 0.043 19.0 3.93 1308 0.06 20 w 270 0.043 19.0 3.93 1060 0.06 16 all 1174 0.043 19.0 3.89 4568 0.06 66 n 104 0.320 0 24.3 2529 10.6 1098 e 32 0.320 0 24.3 778 34.4 1102 s 106 0.320 0 24.3 2586 18.9 2007 all 242 0.320 0 24.3 5894 17.4 4207 n 41 0.150 6.7 11.4 472 2.77 115 45 0.020 50.0 1.52 68 0.84 38 1139 0.020 50.0 1.52 1731 0.84 957 319 0.035 30.0 2.66 849 0.07 22 wrlgtltSOft' Right -Suite® U niversal 2017 17.0.10 RSU20477 2017 -Feb -2108:57:53 Page 1 ...are\KartchnenFS888 princelon with basement.mp Calc=MJB House faces: N 21A -24c: Bg Floor, heavy dry or light damp soil, 6' depth, carpet Flr fnsh all 762 0.025 0 1.90 1448 43 0.025 0 1.90 82 60 0.025 0 1.90 114 865 0.025 0 1.90 1643 � 2017 -Feb -21 08.57:53 /11.� WPI9htSOW Right -Suite® U niversal 2017 17.0.10 RSU20477 Paget ...are\KartchnerTS6B8 pnnceton vnth basement,rup Calc =MJ8 House faces: N Project SJob: FS6B8 wrightsil 1 Summary Date: 2/21/17 Entire House By: Vince Byram Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-745-7329 Email: highcountryph@yahoo.com For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Notes: Weather: Idaho Falls, D. US Winter Design Conditions Summer Design Conditions Outside db -6 °F Outside db 89 °F Inside db 70 *F Inside db 75 °F Design TO 76 *F Design TD 14 *F AHRI ref 2002183 Daily range H Coil Capf303Obx Relative humidity 50 % Moisture difference -31 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 34948 Btuh Structure 7544 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (44 cfm) 3121 Btuh Central vent (44 cfm) 575 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh 6900 Btuh Temperature rise Equipment load 38069 Btuh Use manufacturer's data n 23000 Btuh Rate/swing multiplier 0.94 Infiltration Equipment sensible load 7632 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 0.113 cfm/Btuh Static pressure Fireplaces 0 Structure -1199 Btuh 0.70 in H2O Ducts 0 Btuh Heating Cooling Central vent (44 cfm) -799 Btuh Area (ftp 2624 2624 Equipment latent load 0 Btuh Volume (fts) 19044 19044 Air changes/hour 0.41 0.21 Equipment total load 7632 Btuh Equiv. AVF (cfm) 130 67 Req. total capacity at 0.70 SHR 0.9 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg. Make Goodman Mfg. Trade GOODMAN Trade GOODMAN, JANITROL, AMANA DISTI... Model GMH950703BX Cond GSX130241C* AHRI ref 2002183 Coil Capf303Obx I ref 4765510 Efficiency 95 AFUE Efficiency 11.0 EER, 13 SEER Heating input 69000 Btuh Sensible cooling 16100 Btuh Heating output 52440 Btuh Latent cooling 6900 Btuh Temperature rise 67 *F Total cooling 23000 Btuh Actual air flow 850 cfm Actual air flow 850 cfm Air flow factor 0.024 cfm/Btuh Air flow factor 0.113 cfm/Btuh Static pressure 0.70 in H2O Static pressure 0.70 in H2O Space thermostat Load sensible heat ratio 1.00 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. W1'1 tlt:siaft' 2017 -Feb -2108:57:53 g Right -Suite® Universal 201717.0.10 RSU20477 Page 1 ...are\Kmtchner\FS6B8 princelon with basement.iup Calc =MJ8 House faces: N AED Assessment Job: FS6B8 Wrlght5oft' case: vzun Entire House By: Vince Byram Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, to 83442 Phone: 208-7467021 Fax: 208-745-7329 Email: highcountryph@yahoo.com For: Location: Idaho Falls, ID, US Elevation: 4741 ft Latitude: 44°N Outdoor: Dry bul b (°F) Daily range (T) Vtkt bulb (°F) Wind speed (mph) Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Heating -6 15.0 Cooling 89 34 ( H ) 60 7.5 .rO r - r� Indoor: Heating Indoor temperature (T) 70 Design TD (T) 76 Relative humidity (%) 50 Moisture difference (gr/Ib) 61.5 Infiltration: w.mo, i �«m i a� i neormi Maximum hourly glazing load exceeds average by 35.0%. House does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 261 Btuh (PFG - 1.3*AFG) Cooling 75 14 50 -31.5 2017 -Feb -21 08:57:53 k. + wrightsoft' Right -suite@ Universal 2017 17.0.10 Rsu20477 Page 1 R1a& _.areWarichner\F5688 princeton with basement top Calc =MJ8 House faces: N wrightsoft• Right -J® Worksheet Entire House Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208.745-7021 Fax: 208-745-7329 Email: highceuntryph@yahoo.com Job: FS6B8 Date: 2/21/17 By: Vince Byrom 1 Room name Entire House Rooml 2 Exposed wall 400.0 It 101.0 It 3 Room height 9.0 It d 9.0 It heat/coot 4 Room dimensions 1.0 x 604.0 It 5 Room area 2624.0 fP 604.0 HI Ty Construction U -value Or HTM Area (fix) Load Area (f P) Load number (Btuh/ft"F (Btuh/ft) or perimeter (h) (Btuh) or perimeter (8) (Bluh) Heat Cool Gross N/P/S Heat I Cool II Gross WP/S Heat Cool 6 Y 12F-Osw 0.065 n 4.94 0.47 603 458 2260 217 216 170 840 81 61C 0.320 n 24.32 10.56 104 0 2529 1098 25 0 608 264 metal 0.150 n 11.40 2.78 41 41 472 115 21 21 239 58 w75879-Owo-6 0.069 n 3.93 0.06 333 333 1308 20 0 0 0 0 11 W 72F-Osw 0.065 a 4.94 0.47 585 585 2890 278 297 297 1467 141 4}J 15819-0wc6 0.069 a 3.75 0.04 270 238 892 10 0 0 0 0 �-G 61C 0.320 a 24.32 34.42 32 0 778 1102 0 0 0 0 4t/ 12F-Osw 0.065 s 4.94 0.47 648 542 2676 257 216 160 789 76 T -C 61C 0.320 s 24.32 18.88 106 0 2586 2007 56 0 1370 1063 IN 15B19-Owa6 0.069 s 3.93 0.06 333 333 1308 20 0 0 0 0 W 12F-Osw 0.065 w 4.94 0.47 558 558 2757 265 180 180 889 85 w 15819-Owc-6 0.069 w 3.93 0.06 270 270 1060 16 0 0 0 0 C 16B-50ad 0.020 1.52 0.84 45 45 68 38 0 0 0 0 C 16B-50ad 0.020 1.52 0.84 1139 1139 1731 957 22 22 33 18 F 20P -30c 0.035 - 2.66 0.07 319 319 849 22 0 0 0 0 F 21A -24c 0.025 - 1.90 0.00 762 762 1448 0 0 0 0 0 F 21A -24c 0.025 1.90 0.00 43 43 82 0 43 43 82 0 F 21A -24c 0.025 - 1.90 0.00 60 60 114 0 0 0 0 0 61 c) AED excursion 267 171 Envelope loss/gain 25808 6fi82 6377 1956 12 a) Infiltration 9140 862 2972 280 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines filo 13) 34948 7544 9289 2238 Less extern al load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal34948 7544 9289 2238 15 Duct loads 0% 0% 0 0 -0% 0%1 0 0 78501 92261 2238 1 Air reg ired (cfrm OI 2521 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -rk wrigh"oft- 2017 -Feb -21 08:57:53 Aft, Right -Suite® U niversal 201717.0.10 RSU20477 Page 1 ...are\KartchneAFS6Be pdnceton vith basementrup Calc =MJB House faces: N wrightsoft• Right -J® Worksheet Entire House Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208-7467021 Fax: 208-745-7329 Email: highmuntryph@yahoo.com Job: FS6B8 Date: 2121/17 By: Vince Byram 1 Room name Room2 Room3 2 Exposed wall 24.0 ft 25.0 ft 3 Room height 9.0 It heaVceol 9.0 ft heaVwol 4 Room dimensions 1.0 x 116.0 It 10.0 x 15.0 It 5 Room area 116.0 It, 150.0 fP Ty Construction U -value I Or HTM I Area (W) I Load I Area (ft2) Load number � (Btuh/f P -°F (1310/1P) or perimeter (fp (Bluh) or perimeter (f) I (Btuh) Heat Cool Gross NIP/S Heat Coal Gross WP/S Heat Cool 6 V[:! I2F-0sw 0.065 n 4.94 0.47 63 43 210 20 0 0 0 0 61 C 0.320 n 24.32 10.56 0 0 0 0 0 0 0 0 metal 0.150 n 11.40 2.78 20 20 233 57 0 0 0 0 w 15879-Owu6 0.069 n 3.93 0.06 0 0 0 0 0 0 0 0 71 w 12F -Ow 0.065 a 4.94 0.47 0 0 0 0 135 135 667 64 4jJ 151379-0wc-6 0.069 a 3.75 0.04 0 0 0 0 0 0 0 0 T -G 61C 0.320 a 24.32 34.42 0 0 0 0 0 0 0 0 tQ/ 12F-Osw 0.065 s 4.94 0.47 63 63 311 30 90 90 445 43 T -G 87C 0.320 s 24.32 18.88 0 0 0 0 0 0 0 0 w 15B19 -Owe -6 0.069 s 3.93 0.06 0 0 0 0 0 0 0 0 w 12F-Osw 0.065 w 4.94 0.47 90 90 445 43 0 0 0 0 w 15819-0wc-6 0.069 w 3.93 0.06 0 0 0 0 0 0 0 0 C 768-50ad 0.020 - 1.52 0.84 0 0 0 0 0 0 0 0 C 1613-50ad 0.020 - 1.52 0.84 0 0 0 0 150 150 228 126 F 20P -30c 0.035 2.66 0.07 0 0 0 0 0 0 0 0 F 21A -24c 0.025 - 1.90 0.00 0 0 0 0 0 0 0 0 F 21A -24c 0.025 - 1.90 0.00 0 0 0 0 0 0 0 0 F 21A -24c 0.025 - 1.90 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion -15 -20 Envelope loss/gain 7799 735 1339 272 12 a) Infiltration 706 67 736 69 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1905 201 2075 282 Lessextemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1905 201 2075 282 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 ( room 9461 2231 20501 282 1 Artlrequi d (cf.) 1 1 1 321 J•. Calculations aooroved by ACCA to meet all requirements of Manual J 8th Ed. �. .'r wrigh>tsaft` 2017 -Feb -2108:57:53 Right -Suite® Universal 2017 17.0.10 RSU20477 Page 2 ...are\Kanchnef\FS6B8 princeton with basementrup Calc =MJ8 House faces: N wrightsoft, Right -M Worksheet Entire House Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-745 7329 Email: highwunlryph@yahoo.com Job: FS688 Date: 2/21117 By: Vince Byram 1 Room name Room4 Room5 2 Exposed all 31.0 ft 14.0 ft 3 Room height 9.0 ft heal/cool 9.0 ft heal/cool 4 Room dimensions 1.0 x 250.0 ft 1.0 x 242.0 ft 5 Room area 250.0 H2 242.0 ft' Ty value I Or I HTM Area (1P) I Load I Area (f t2) Loatl-� �onsmction number Ent (etuh/ft2-°F (Btuh/f R) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool r 6 12F-0sw 0.065 n 4.94 0.47 135 106 524 50 0 0 0 0 61C 0.320 n 24.32 10.56 29 0 705 306 0 0 0 0 metal 0.150 n 11.40 2.78 0 0 0 0 0 0 0 0 w15819-O.vc-6 0.069 n 3.93 0.06 0 0 0 0 0 0 0 0 11 w M-Osw 0.065 a 4.94 0.47 144 144 711 68 0 0 0 0 15879-Owo6 0.069 a 3.75 0.04 0 0 0 0 0 0 0 0 61C 0.320 a 24.32 34.42 0 0 0 0 0 0 0 0 4�J 12F-Osw 0.065 s 4.94 0.47 0 0 0 0 126 101 499 48 L --G 61C 0.320 s 24.32 18.88 0 0 0 0 25 0 608 472 w 15Bl9-Owo6 0.069 s 3.93 0.06 0 0 0 0 0 0 0 0 w 12F-0sw 0.065 w 4.94 0.47 0 0 0 0 0 0 0 0 w 15B19-Owc-6 0.069 w 3.93 0.06 0 0 0 0 0 0 0 0 C 16B-50ad 0.020 - 1.52 0.84 0 0 0 0 0 0 0 0 C 16B-50ad 0.020 - 1.52 0.84 250 250 380 210 242 242 368 203 F 20P -30c 0.035 - 2.66 0.07 0 0 0 0 0 0 0 0 F 21A -24c 0.025 - 1.90 0.00 0 0 0 0 0 0 0 0 F 21A -24c 0.025 - 1.90 0.00 0 0 0 0 0 0 0 0 F 21A -24c 0.025 - 1.90 0.00 0 0 0 0 60 60 114 0 6 c)AED excursion -49 90 Envelope loss/gain 2320 586 1589 813 12 a) Infiltration 912 86 412 39 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 3232 672 2001 852 Less e m mal load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 3232 672 2:0U 15 Duct loads -0% 0% 0 0 -0% 0% m load Air 32791 6781 200112 8961 requal ired (c m) I I I 491 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrishtsoft' Right-Sulte®Universal 2017 W.0.10 RSU20477 2017 -Feb -21 08:57:53 ...are\Kartchner\FS688 princeton with basement. mp Calc = MJ8 House faces: N Page 3 wrightsoft• Right -J® Worksheet Entire House Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208-7457021 Fax: 208-745-7329 Email: highcountryph@yahoo.com Job: FS6B6 Date: 2/21/17 By: Vince Byram I Room name ROom7 ROomS 2 Exposed wall 5.0 It 14.0 ft 3 Room height 9.0 Fl heaUcool 9.0 fl heaf/cool 4 5 Room dimensions Room area 9.0 x 5.0 it 45.0 ft' 11.0 x 14.0 fl 154.0 ft' Ty Construction U -value Or HTM Area (W) I Load Area (w) Load number (Bt uhlf P -°F (Btuh/ftp or perimeter (fp (Bluh) or perimeter (0) I (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11/ 12F-Osw 0.065 n 4.94 0.47 0 0 0 0 99 74 366 35 61C 0.320 n 24.32 10.56 0 0 0 0 25 0 608 264 metal 0.150 n 11.40 2.78 0 0 0 0 0 0 0 0 W15819-Owc-6 0.069 n 3.93 0.06 0 0 0 0 0 0 0 0 11 W 12F-Osw 0.065 a 4.94 0.47 0 0 0 0 9 9 44 4 VIJ 15B19-Owo6 0.069 a 3.75 0.04 0 0 0 0 0 0 0 0 �G 61C 0.320 a 24.32 34.42 0 0 0 0 0 0 0 0 4t/ 12F-Osw 0.065 s 4.94 0.47 0 0 0 0 0 0 0 0 t -G 61C 0.320 s 24.32 18.88 0 0 0 0 0 0 0 0 W 15819-OWC-6 0.069 s 3.93 0.06 0 0 0 0 0 0 0 0 W12F-Osw 0.065 w 4.94 0.47 45 45 222 21 18 18 89 9 W 15B19-Owc-6 0.069 w 3.93 0.06 0 0 0 0 0 0 0 0 C 16B-50ad 0.020 - 1.52 0.84 0 0 0 0 0 0 0 0 C 16B-50ad 0.020 - 1.52 0.84 45 45 68 38 154 154 234 129 F 20P -30c 0.035 - 2.66 0.07 45 45 120 3 154 154 410 11 F 21A -24c 0.025 - 1.90 0.00 0 0 0 0 0 0 0 0 F 21A -24c 0.025 - 1.90 0.00 0 0 0 0 0 0 0 0 F 21A24c0.025 - 1.90 000 0 0 0 0 0 0 0 0 61 c) AED excursion -5 -33 Envelope loss/gain 410 57 1757 419 12 a) Infiltration 147 14 412 39 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants Q 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 558 71 2163 458 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 558 71 2163 458 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 load 5141 '61 21531 4558 Aotaequomd 1 I I I I 21 Calculations aDDroved by ACCA to meet all requirements of Manual J 8th Ed. Js- -Pk- wrightsaft' 2077 -Feb -2108:57:53 Right -Su ite® U niv er sal 201717.0.10 RSU20,177 Page ...are\Kanchner\FS6B8 princeton with basement.rup Cato =MJ8 House faces: N ►}► wrightsoft• Right -J® Worksheet Entire House Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208-7457021 Fax'. 208-745-7329 Email: highwuntryph@yahoo.com Job: FS6B8 Date: 2/21/17 By: Vince Byram 1 Room name Room9 Room6 2 Exposed wall 22.0 R 25.0 ft 3 Room height 9.0 At he.tl.ol 9.0 It heat/cool 4 Room dimensions 10.0 x 120 It 12.0 x 13.0 R 5 Room area 120.0 W 156.0 fP Ty Construction U -value I Or I HTM I Area (f P) Load I Area (f t') I Load number (Blah/fY-°F (Btuh/ft2) or perimeter (iq (Bluh) or perimeter (fp (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heal Cool Illli 6 12F-0sw 0.065 n 4.94 0.47 90 65 321 31 0 0 0 0 61C 0.320 n 24.32 10.56 25 0 608 264 0 0 0 0 metal 0.150 n 11.40 2.78 0 0 0 0 0 0 0 0 W15679-Owc-6 0.069 n 3.93 0.06 0 0 0 0 0 0 0 0 11 W 12F-Osw 0.065 a 4.94 0.47 0 0 0 0 0 0 0 0 t 151319-Owc-6 0.069 a 3.75 0.04 0 0 0 0 0 0 0 0 -G 61C 0.320 a 24.32 34.42 0 0 0 0 0 0 0 0 1N 12F-Osw 0.065 s 4.94 0.47 0 0 0 0 108 83 410 39 -G 61C 0.320 s 24.32 18.88 0 0 0 0 25 0 608 472 W 151379-Owc-6 0.069 s 3.93 0.06 0 0 0 0 0 0 0 0 W 12F-0sw 0.065 w 4.94 0.47 108 108 534 51 117 117 578 56 W 15W1 Owc-6 0.069 w 3.93 0.06 0 0 0 0 0 0 0 0 C 16B-50ad 0.020 - 1.52 0.84 0 0 0 0 0 0 0 0 C 1613-50ad 0.020 - 1.52 0.84 120 120 182 101 156 156 237 131 F 20P -30c 0.035 - 2.66 0.07 120 120 319 8 0 0 0 0 F 21A -24c 0.025 - 1.90 0.00 0 0 0 0 0 0 0 0 F 21A -24c 0.025 - 1.90 0.00 0 0 0 0 0 0 0 0 F 21A -24c 0.025 - 1.90 0.00 0 0 0 0 0 0 0 0 61 c)AED excursion -35 89 Envelope loss/gain 1964 420 1 1 1833 787 12 a) Infiltration 647 61 736 69 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 2611 481 2569 857 Less exlemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2611 481 2569 857 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 load A! 26fi4I 4541 25869 8 equiom red (c m) I I I I 21 97I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htleoft' 2017 -Feb -2108:57:53 9 Right -Suited U niversal 2017 17.0.10 RSU20477 Pages ...are\Kartc1ner\FS6B8 princeton with basement rap Calc = MJ8 House faces: N I#wrightsoft• Right -JO Worksheet Entire House Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208 7457021 Fax: 208-745-7329 Email: highcoun"ph@yahoo.com Job: FS6B8 Date: 2121/17 By: Vince Byram 1 Room name Room10 Room11 2 Exposed wall 75.0 n 59.0 ft 3 Room height 9.0 8 heaVcool 9A ft heaVcool 4 Room dimensions 1.0 x 441.0 It 1.0 x 321.0 ft 5 Room area 441.0 ft' 321.0 ft' Ty Construction U -value Or HTM Area (fl') Load Area (f P) I Load number (Bt uh/f t' -°F (et Out or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12F-0sw 0.065 n 4.94 0.47 0 0 0 0 0 0 0 0 61Ct 0.320 n 24.32 10.56 0 0 0 0 0 0 0 0 metal 0.150 n 11.40 2.78 0 0 0 0 0 0 0 0 W 15Bi9-0wc-6 0.069 n 3.93 0.06 153 153 601 9 180 180 707 11 11 W 12F-0sw 0.065 a 4.94 0.47 0 0 0 0 0 0 0 0 W/ 15819-0wc-6 0.069 a 3.75 0.04 261 229 857 10 9 9 35 1 �G 61C 0320 a 24.32 34.42 32 0 778 1102 0 0 0 0 t 12F-0sw 0.065 s 4.94 0.47 0 0 0 0 0 0 0 0 -G 61C 0.320 s 24.32 18.88 0 0 0 0 0 0 0 0 W 15B19-Owc-6 0.069 s 3.93 0.06 117 117 459 7 216 216 848 13 W12F-0sw 0.065 w 4.94 0.47 0 0 0 0 0 0 0 0 W 15819-Owc-6 0.069 w 3.93 0.06 144 144 565 9 126 126 495 8 C 16B-50ad 0.020 - 1.52 0.84 45 45 68 38 0 0 0 0 C 16B-50ad 0.020 - 1.52 0.84 0 0 0 0 0 0 0 0 F 20P -30c 0.035 - 2.66 0.07 0 0 0 0 0 0 0 0 F 21A24c0.025 - 1.90 0.00 441 441 838 0 321 321 610 0 F 21A -24c 0.025 - 1.90 0.00 0 0 0 0 0 0 0 0 F 21A -24c 0.025 - 1.90 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion 76 .6 Envelope loss/gain 1 4167 1250 2695 28 12 a) Infiltration 736 69 579 55 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 4903 1319 3274 81 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 4903 1319 3274 81 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 1 At 49191 01 11491 32801 891 reequomdl can) 1 1 1 1 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrI htsaft" 2017 -Feb -2108:57:53 4 Right -Suite® U niversal 2017 17.0.10 RSU20477 Page ...are\Kadchner\FS6B8 princeton with basement,rup Calc= MJB House faces: N wrightsoft• Right -M Worksheet Entire House Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208-748-7021 Fax: 208-745-7329 Email: highcountryph@yahoo.com Job: FUN Date: 2/21/17 By: Vince Byram 1 Room name Rooml3 2 Exposed wall 5.0 It 3 Room height 9.0 It heat/cool 4 Room dimensions 5.0 x 5.0 ft 5 Room area 25.0 fl' Ty Canal.ran U -value I Or I HTM Area (f P) Load Area I Load number (Btuh/f t' -°F (Bt uh/ft') or perimeter (n) (Bluh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 8 4}J 12F-Osw 0.065 n 4.94 0.47 0 0 0 0 61Ct 0.320 n 24.32 10.56 0 0 0 0 L�-DG metal 0.150 n 11.40 2.78 0 0 0 0 W 151319-0wc-6 0.069 n 3.93 0.06 0 0 0 0 11 W 12F-Osw 0.065 a 4.94 0.47 0 0 0 0 l5J 15B79-Owc-6 0.069 a 3.75 0.04 0 0 0 0 L --G 61C 0.320 a 24.32 34.42 0 0 0 0 4)J 12F-Osw 0.065 s 4.94 0.47 45 45 222 21 T -G 61C 0.320 s 24.32 18.88 0 0 0 0 W 15819-Owc-6 0.069 s 3.93 0.06 0 0 0 0 W12F-Osw 0.065 w 4.94 0.47 0 0 0 0 W M19-Owc-6 0.069 w 3.93 0.06 0 0 0 0 C 16BSeed0.020 - 1.52 0.84 0 0 0 0 C 16B-50ad 0.020 - 1.52 0.84 0 0 0 0 F 20P -30c 0.035 - 2.66 0.07 0 0 0 0 F 21A -24c 0.025 - 1.90 0.00 0 0 0 0 F 21A -24c 0.025 - 1.90 0.00 0 0 0 0 F 21A -24c 0.025 - 1.90 0.00 0 0 0 0 61 c) AED excursion -2 Envelope loss/gain 222 191 1 12 a) Infiltration 147 14 IF) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13) 369 331 i Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 369 33 15 Duct loads -0% 0% 0 0 Total load 3691 331 room Airre uired cfm) I I 9 4 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 41,11- wrightsaft- 2017 -Feb -21 08:57:53 Rig fit Universal 2017 17.0.10 RSU20477 Page 7 ... areW rtchneAFS6B8 pdnceton with basemenl.rup Calc =MJ8 House faces: N 2nd Story 96 cfm ®` 97 cfm ®`50 cfm j� 97 cfm Room6 Room3 04 cfm Room5 Room7 ® 14 cfm �129cm 64 cfm Room4 F� Raom8 3 cfm Room9 9`39 cfm g`39cfm g'64 cling 53 cfm Job #: FS6B8 Performed by Vince Byram for: Cody Puzey 3758 Yellowstone$ Hwy Idaho Falls, Id 83401 Phone: 208-529-2116 Modern Plumbing, Heating, and EI... P.O. Box 627 Rigby, Id 83442 Phone: 208-745-7021 Fax 208-745-7329 highcountryph@yahoo.com Scale: 1 : 85 Page 1 Right -Suite ®U n i versa 12017 17.0.10 RSU20477 2017 -Feb -21 09:00:31 ...S6B8 princeton with basement.rup Main Floor Job #: FS6B8 Performed by Vince Byram for: Cody Puzey 3758 Yellowslones Hwy Idaho Falls, Id 83401 Phone: 208-529-2116 Modern Plumbing, Heating, and EI... P.O. Box 627 Rigby, Id 83442 Phone: 208-745-7021 Fax 208-745-7329 h ig hcountryph@yahoo. corn Riser Riser Scale: 1 : 85 Page 2 Right-Sui teO U ni versa 12017 17.0.10 RSU20477 2017 -Feb -21 09:00:31 .5668 princeton with basementrup basement Job #: FS6138 Performed by Vince Byram for: Cady Puzey 3758 Yellowstones Hwy Idaho Falls, Id 83401 Phone: 208-529-2116 Modern Plumbing, Heating, and EI... P.O. Box 627 Rigby, Id 83442 Phone: 208-745-7021 Fax. 208-745-7329 highwuntryph@yahoo.com Riser Riser Scale: 1 : 85 Page 3 Ri ghl-Suite® Universal 2017 17.0. 10 RSU20477 2017 -Feb -21 09:00:31 .86138 princeton with basement rup Duct System Summary Dub: FS6B8 wrightsoft Date: 2/21/17 Entire House By: Vince Byram Modern Plumbing, Heating, and Electric P.O. Box 627, Rigby, Id 83442 Phone: 208.7457021 Fax 208-7457329 Email: highcountryph@yahoo.com For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 585 ft Cooling 0.70 in H2O 0.29 in H2O 0.41 in H2O 0.220 / 0.190 in H2O 0.070 in/100ft 850 cfm Name Heating External static pressure 0.70 in H2O Pressure losses 0.29 in H2O Available static pressure 0.41 in H2O Supply / return available pressure 0.220 / 0.190 in H2O Lowest friction rate 0.070 in/100ft Actual air flow 850 cfm Total effective length (TEL) 0.078 585 ft Cooling 0.70 in H2O 0.29 in H2O 0.41 in H2O 0.220 / 0.190 in H2O 0.070 in/100ft 850 cfm Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matt Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Rooms c 560 56 63 0.078 6.0 0x0 ShMt 37.0 245.0 stlB Rooms -A c 560 56 63 0.133 6.0 0x0 ShMt 25.0 140.0 stl Rooms -B c 560 56 63 0.070 6.0 0x0 ShMt 49.0 265.0 st1B Rooms -C c 560 56 63 0.101 6.0 0x0 ShMt 38.0 180.0 st1A Room10 c 660 60 74 0.096 6.0 0x0 ShMt 58.4 170.0 st2 Room10-A c 660 60 74 0.099 6.0 0x0 ShMt 51.4 170.0 st2 Room11 h 3274 80 9 0.102 6.0 0x0 ShMt 35.4 180.0 st2 Rwm13 h 369 9 4 0.116 6.0 0x0 ShMt 14.0 175.0 stl Room2 h 953 23 11 0.120 6.0 Oxo ShMt 8.0 175.0 stl Room2-B h 953 23 11 0.128 6.0 Oxo ShMt 12.0 160.0 stl Room3 h 2075 50 32 0.088 6.0 Oxo ShMt 36.0 215.0 st1A Room4 h 1616 39 38 0.100 6.0 Oxo ShMt 40.9 180.0 st1A Room4-A h 1616 39 38 0.081 6.0 0x0 ShMt 46.0 225.0 st1A Room5 c 852 49 96 0.142 6.0 0x0 ShMt 25.0 130.0 ell Rooms c 857 62 97 0.118 6.0 0x0 ShMt 12.0 175.0 stl Room7 h 558 14 8 0.118 6.0 Oxo ShMt 11.0 175.0 stl Rooms h 2163 53 52 0.120 6.0 0x0 ShMt 33.0 150.0 stl Room9 h 2611 64 54 0.116 6.0 Oxo ShMt 25.0 165.0 stl + WYlgihteoft• Right-Suite(l) Universal 2017 17.0.10 RSU20477 ...are\KBrtchner\FS6B8 Princeton with basement.mp Calc =We House faces: N 2017 -Feb -21 08:57:54 Page 1 Name Trunk Htg Clg Design Veloc Diam H x W Duct Stud/Joist Opening (in) Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1A Peak AVF 299 297 0.070 448 9.4 8 x 12 ShtMetl st1 st2 Peak AVF 199 158 0.096 570 8.0 0 x 0 ShtMetl 54 st1B Peak AVF 113 126 0.070 284 6.8 8 x 8 ShtMetl st1A SO Peak AVF 651 692 0.070 623 12.9 8 x 20 ShtMetl rt2 Name Grille Size (in) Htg (cfm) Clg (dm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mat[ Trunk rb7 0x0 199 158 135.0 0.141 629 7.0 3.25x14 10x9 SJSp 692 rb2 0x0 62 97 96.1 0.198 305 5.0 3.25x14 10x9 SJSp rt2 rb3 0x0 64 54 92.1 0.206 201 4.2 3.25x14 10x9 SJSp rt2 rb4 0x0 53 52 99.1 0.192 166 4.0 3.25x14 10x9 SJSp rt2 rb6 0x0 62 104 114.1 0.166 329 5.3 3.25x14 10x9 SJSp rt2 rb1 0x0 281 279 212.1 0.090 445 8.8 2-3.25x14 2-10x18 SJSp rt2 rb5 0x0 129 107 271.1 0.070 409 6.9 3.25x14 10x9 SJSp rt2A 2017 -Feb -2108:57:54 wri htSOft Right-Suite®Universa1207717.0.10 RSU20477 Paget kkA..arekKanchner1FS688 prineeton with basement.rup Cate =MJ8 House faces: N Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt2 Peak AVF 651 692 0.070 623 12.9 8 x 20 ShtMetl rt2A Peak AVF 129 107 0.070 194 6.9 8 x 12 ShtMetl rt2 2017 -Feb -2108:57:54 wri htSOft Right-Suite®Universa1207717.0.10 RSU20477 Paget kkA..arekKanchner1FS688 prineeton with basement.rup Cate =MJ8 House faces: N