HomeMy WebLinkAboutCOMCHECK - 17-00097 - 415 W 6th S - Falls Pointe Apt - 42 UnitsCOMcheck Software Version 4.0.5.1 Envelope Compliance Certificate Project Information Energy Code: Project Title: Location: Climate Zone: Project Type: Vertical Glazing / Wall Area: Construction Site: Rexburg, ID Building Area 2012 IECC Liljenquist Apartments Rexburg, Idaho 6b New Construction 22% Owner/Agent: Designer/Contractor: Dwayne Sudweeks Engineered Systems Assoc., Inc. 1355 E. Center St. Pocatello, ID 83201 208-233-0501 dcs@engsystems.com Floor Area 1 -Multifamily : Nonresidential 30860 Additional Efficiency Package High efficiency HVAC. Systems that do not meet the performance requirement will be identified in the mechanical requirements checklist report. Envelope Assemblies Assembly Gross Area Cavity Cont. Proposed Budget U - or R -Value R -Value U -Factor Factor(.) Perimeter Roof 1: Attic Roof with Wood Joists, [Bldg. Use 1 - Multifamily] 10289 38.0 0.0 0.027 0.021 Exterior Wall 1: Wood -Framed, 16" o.c., [Bldg. Use 1 - Multifamily] 5640 19.0 0.0 0.067 0.051 Window 1: Vinyl/Fiberglass Frame:Operable, Perf. Type: Energy code 908 --- --- 0.550 0.430 default, Double Pane, Clear, SHGC 0.70, [Bldg. Use 1 - Multifamily] Door 1: Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Type: 120 --- --- 0.800 0.770 Energy code default, Double Pane, Clear, SHGC 0.70, [Bldg. Use 1 - Multifamily] Door 2: Insulated Metal, Swinging, [Bldg. Use 1 - Multifamily] 24 --- --- 0.130 0.370 Exterior Wall 2: Wood -Framed, 16" o.c., [Bldg. Use 1 - Multifamily] 9716 19.0 7.5 0.043 0.051 Window 2: Vinyl/Fiberglass Frame:Operable, Perf. Type: Energy code 2273 --- --- 0.550 0.430 default, Double Pane, Clear, SHGC 0.70, [Bldg. Use 1 - Multifamily] Floor 1: Slab -On -Grade: Unheated, Vertical 3 ft., [Bldg. Use 1 - 564 --- 10.0 0.510 0.540 Multifamily] (b) (a) Budget U -factors are used for software baseline calculations ONLY, and are not code requirements. (b) Slab -On -Grade proposed and budget U -factors shown in table are F -factors. Project Title: Liljenquist Apartments Report date: 03/03/17 Data filename: C:\Users\Dwayne 15\Documents\COMcheck\liljenquist Arch.cck Page 1 of 9 Project Title: Liljenquist Apartments Report date: 03/03/17 Data filename: C:\Users\Dwayne 15\Documents\COMcheck\liljenquist Arch.cck Page 2 of 9 COMcheck Software Version 4.0.5®1. Inspection Checklist Energy Code: 2012 IECC Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review � Complies? Comments/Assumptions L & Req.lD C103.2 Plans and/or specifications provide all ❑Complies [PRI]1 information with which compliance ❑Does Not can be determined for the building envelope and document where ❑Not Observable exceptions to the standard are ❑Not Applicable claimed. C406 Plans, specifications, and/or ❑Complies [PR9]1 calculations provide all information ❑Does Not with which compliance can be determined for the additional energy ❑Not Observable efficiency package options. ❑Not Applicable pp e C402.3.1 The vertical fenestration area <= 30 ❑Complies i [PR10]1 percent of the gross above -grade wall ❑Does Not area. ❑Not Observable ❑Not Applicable C402.3.1 The skylight area <= 3 percent of the ❑Complies [PR1111 gross roof area. ❑Does Not ❑Not Observable ❑Not Applicable C402.3.2. Skylights in office, storage, ❑Complies 2 automotive service, manufacturing, ❑Does Not [PR15]1 non -refrigerated warehouse, retail ❑Not Observable store, and distribution/sorting area have a measured haze value > 90 ❑Not Applicable percent unless designed to exclude direct sunlight. Additional Comments/Assumptions: 11 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Lilienquist Apartments Report date: 03/03/17 Data filename: C:\Users\Dwayne 15\Documents\COMcheck\liljenquist Arch.cck Page 3 of 9 Section # Footing / Foundation Inspection Complies? Comments/Assumptions & Req.ID C402.2.6 Slab edge insulation R -value. ❑Complies See the Envelope Assemblies table for values. [FO3]2 ❑Does Not ❑Not Observable []Not Applicable C303.2 Slab edge insulation installed per ❑Complies [FO412 manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable C402.2.6 Slab edge insulation depth/length. ❑Complies See the Envelope Assemblies table for values. [FO5]z Slab insulation extending away from ❑Does Not building is covered by pavement or ❑Not Observable >= 10 inches of soil. ❑Not Applicable C403.2.8. Exterior insulation protected against ❑Complies 1 damage, sunlight, moisture, wind, ❑Does Not [FO611 landscaping and equipment ❑Not Observable maintenance activities. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 1 2 Medium Impact (Tier - - 3 Low Impact (Tier 3) Project Title: Liljenquist Apartments Report date: 03/03/17 Data filename: C:\Users\Dwayne 15\Documents\COMcheck\liljenquist Arch.cck Page 4 of 9 Section o Framing / Rough -In Inspection Complies? Comments/Assumptions & Req.ID C402.4.1, The building envelope contains a ❑Complies f C402.4.2 continuous air barrier that is sealed in ❑Does Not [FR16]1 an approved manner and either ❑Not Observable constructed or tested in an approved ❑Not Applicable manner. Air barrier penetrations are sealed in an approved manner. C402.4.3, Factory -built fenestration and doors ❑Complies C402.4.4 are labeled as meeting air leakage ❑Does Not [FR18]3 requirements. ❑Not Observable ❑Not Applicable C402.4.7 Vestibules are installed on all building ❑Complies [FR17]3 entrances. Doors have self-closing ❑Does Not devices. ❑Not Observable ❑Not Applicable C402.3.3, Vertical fenestration U -Factor. ❑Complies See the Envelope Assemblies table for values. C402.3.4 ❑Does Not [FR8]1 ❑Not Observable ❑Not Applicable C402.3.3 Vertical fenestration SHGC value. ❑Complies See the Envelope Assemblies table for values. [FR10]' ❑Does Not ❑Not Observable ❑Not Applicable ' C303.1.3 Fenestration products rated in ❑Complies [FR12]2 accordance with NFRC. ❑Does Not i ❑Not Observable ❑Not Applicable C303.1.3 Fenestration products are certified as ❑Complies [FR13]1 to performance labels or certificates ❑Does Not provided. ❑Not Observable ❑Not Applicable 11-4u z. z. i u -tactor of opaque doors associated UComplies See the Envelope Assemblies table for values. [FR14]2 with the building thermal envelope ❑Does Not meets requirements. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 1 2 !Medium Impact (Tier 2) 3 ,Low Impact (Tier 3) Project Title: Liljenquist Apartments Report date: 03/03/17 Data filename: C:\Users\Dwayne 15\Documents\COMcheck\liljenquist Arch.cck Page 5 of 9 Section # Mechanical Rough -in inspection Complies? Comments/Assumptions & Req.ID , C402.4.5. Stair and elevator shaft vents have ❑Complies 1 motorized dampers that automatically ❑Does Not [ME3]3 close. ❑Not Observable ❑Not Applicable C402.4.5. Outdoor air and exhaust systems have ❑Complies 2 motorized dampers that automatically ❑Does Not [ME58]3 shut when not in use and meet maximum leakage rates. Check ❑Not Observable gravity dampers where allowed. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier Z) 3 1 Low Impact (Tier 3) Project Title: Liljenquist Apartments Report date: 03/03/17 Data filename: C:\Users\Dwayne 15\Documents\COMcheck\liljenquist Arch.cck Page 6 of 9 Section Roof R -value. For some ceiling ❑Complies See the Envelope Assemblies table for values. 1 # Insulation Inspection Complies? Comments/Assumptions & Req.ID . ❑Not Applicable C402.4.1. All sources of air leakage in the ❑Complies 1 building thermal envelope are sealed, ❑Does Not [IN1]1 caulked, gasketed, weather stripped ❑Not Observable or wrapped with moisture vapor- ❑Not Applicable permeable wrapping material to ❑Not Applicable C303.2 minimize air leakage. ❑Complies C402.4.2. Roof R -value. For some ceiling ❑Complies See the Envelope Assemblies table for values. 1 systems, verification may need to ❑Does Not [IN2]1 occur during Framing Inspection. ❑Not Observable ❑Not Applicable C303.2 Roof insulation installed per ❑Complies [IN3]1 manufacturer's instructions. Blown or ❑Does Not poured loose -fill insulation is installed ❑Not Observable only where the roof slope is <=3 in 12. ❑Not Applicable C303.2 Above -grade wall insulation installed ❑Complies [IN7]1 per manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable C402.2.5 Floor insulation R -value. ❑Complies See the Envelope Assemblies table for values. [IN8]2 ❑Does Not ❑Not Observable ❑Not Applicable C303.1 Building envelope insulation is labeled ❑Complies [IN10]2 with R -value or insulation certificate ❑Does Not providing R -value and other relevant ❑Not Observable data. ❑Not Applicable C303.2.1 Exterior insulation is protected from ❑Complies [IN14]2 damage with a protective material. ❑Does Not Verification for exposed foundation ❑Not Observable insulation may need to occur during ❑Not Applicable Foundation Inspection. C402.2.1 Insulation intended to meet the roof ❑Complies [IN17]3 insulation requirements cannot be ❑Does Not installed on top of a suspended ❑Not Observable ceiling. Mark this requirement ❑Not Applicable compliant if insulation is installed accordingly. Additional Comments/Assumptions: rl 1 High Impact (Tier l) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Liljenquist Apartments Report date: 03/03/17 Data filename: C:\Users\Dwayne 15\Documents\COMcheck\liljenquist Arch.cck Page 7 of 9 Section # Final Inspection Complies? & Req.ID C402.4.6 Weatherseals installed on all loading ❑Complies [FI3711 dock cargo doors. ❑Does Not ❑Not Observable ❑Not Applicable C402.4.8 Recessed luminaires in thermal ❑Complies [FI2613 envelope to limit infiltration and be IC ❑Does Not rated and labeled. Seal between ❑Not Observable interior finish and luminaire housing. ❑Not Applicable C406 Efficient HVAC performance, efficient ❑Complies [F13411 lighting system, or on-site supply of ❑Does Not renewable energy consistent with what is shown the approved plans. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: Comments/Assumptions a 1High Impact (Tier 1) 2 1 Medium Impact (Tier 2)J 3 i Low Impact (Tier 3) Project Title: Liljenquist Apartments Report date: 03/03/17 Data filename: C:\Users\Dwayne 15\Documents\COMcheck\liljenquist Arch.cck Page 8 of 9 Project Title: Liljenquist Apartments Report date: 03/03/17 Data filename: C:\Users\Dwayne 15\Documents\COMcheck\liljenquist Arch.cck Page 9 of 9 Mechanical Compliance Certificate Project Information Energy Code: Project Title: Location: Climate Zone: Project Type: Construction Site: Rexburg, ID Additional Efficiency Package Unspecified Mechanical Systems List Quantity System Type & Description 42 HVAC System 1 (Single Zone) 2012 IECC Liljenquist Apartments Rexburg, Idaho 6b New Construction Owner/Agent: Designer/Contractor: Dwayne Sudweeks Engineered Systems Assoc., Inc. 1355 E. Center St. Pocatello, ID 83201 208-233-0501 dcs@engsystems.com Heating: 1 each - Central Furnace, Gas, Capacity = 36 kBtu/h Proposed Efficiency = 80.00% Et, Required Efficiency = 80.00% Et Cooling: 1 each - Single Package DX Unit, Capacity = 18 kBtu/h, Air -Cooled Condenser, No Economizer, Economizer exception: Low Capacity Residential Proposed Efficiency = 13.00 SEER, Required Efficiency: 13.00 SEER Fan System: FAN SYSTEM 1 -- Compliance (Motor nameplate HP method) : Passes Fans: FAN 1 Supply, Constant Volume, 600 CFM, 0.3 motor nameplate hp 42 Water Heater 1: Gas Storage Water Heater, Capacity: 50 gallons, Input Rating: 75 Btu/h Proposed Efficiency: 0.80 EF, Required Efficiency: 0.53 EF 1 Water Heater 2: Electric Storage Water Heater, Capacity: 20 gallons No minimum efficiency requirement applies Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2012 IECC requirements in COMcheck Version 4.0.5.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Dwaqpe Name - Titl Signature I Date Project Title: Liljenquist Apartments Report date: 03/03/17 Data filename: C:\Users\Dwayne 15\Documents\COMcheck\liljenquist mech.cck Page 1 of 9 COMcheck Software Version 4.0.5®1 Inspection Checklist Energy Code: 2012 IECC Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # & Req.iD Plan Review Complies? t—Com—plies — - Comments/Assumptions C103.2 Plans, specifications, and/or [PR2]1 calculations provide all information ❑Does Not with which compliance can be ❑Not Observable determined for the mechanical systems and equipment and ❑Not Applicable document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. C103.2 Plans, specifications, and/or ❑Complies [13113]1 calculations provide all information ❑Does Not with which compliance can be ❑Not Observable determined for the service water heating systems and equipment and ❑Not Applicable document where exceptions to the standard are claimed. Hot water system sized per manufacturer's sizing guide. C406 Plans, specifications, and/or ❑Complies [PR9]1 calculations provide all information ❑Does Not with which compliance can be ❑Not Observable determined for the additional energy ❑Not Applicable efficiency package options. Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 j Low Impact (Tier 3) Project Title: Liljenquist Apartments Report date: 03/03/17 Data filename: C:\Users\Dwayne 15\Documents\COMcheck\liijenquist mech.cck Page 2 of 9 # I Footing / Foundation inspection Complies? Comments/Assumptions Req.ID C403.2.4. Freeze protection and snow/ice ❑Complies 5 melting system sensors for future ❑Does Not [Fog]3 connection to controls. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: Liljenquist Apartments Report date: 03/03/17 Data filename: C:\Users\Dwayne 15\Documents\COMcheck\liljenquist mech.cck Page 3 of 9 Section # I Plumbing Rough -in inspection Complies? Comments/Assumptions & Req.ID C404.3 Temperature controls installed on ❑Complies [PL5]3 service water heating systems (110 F ❑Does Not for dwelling units and lavatories in ❑Not Observable public restrooms and 90 F for other occupancies.) ❑Not Applicable C404.3 Temperature controls installed on ❑Complies [PL5]3 service water heating systems (110 F ❑Does Not for dwelling units and lavatories in public restrooms and 90 F for other []Not Observable occupancies.) ❑Not Applicable C404.2 Heat traps installed on non -circulating ❑Complies I: [PL4]3 storage water tanks. ❑Does Not ❑Not Observable ❑Not Applicable eC404.2 Heat traps installed on non -circulating ❑Complies [PL4]3 storage water tanks. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: Li I High Impact (Tier 1) 2 ct (Tier 2) 3 Low Impact (Tier 3) Project Title: Liljenquist Apartments Report date: 03/03/17 Data filename: C:\Users\Dwayne 15\Documents\COMcheck\liljenquist mech.cck Page 4 of 9 Section _ #Mechanical Rough -In Inspection I Complies? Comments/Assumptions & Req.ID C403.2.3 HVAC equipment efficiency verified. ❑Complies See the mechanical systems list for values. (ME55]2 ❑Does Not ❑Not Observable ❑Not Applicable C403.2.5. Demand control ventilation provided ❑Complies 1 for spaces >500 sq.ft. and >25 ❑Does Not (ME591I people/1000 scift occupant density ❑Not Observable and served by systems with air side ❑Not Applicable economizer, auto modulating outside air damper control, or design airflow >3,000 cfm. C403.2.7 HVAC ducts and plenums insulated. ❑Complies [ME60]2 Where ducts or plenums are installed []Does Not in or under a slab, verification may ❑Not Observable need to occur during Foundation Inspection. ❑Not Applicable C403.2.8. Piping Insulation exposed to weather ❑Complies 1 is protected from damage (due to sun, ❑Does Not 1[ME713 f❑Not moisture, wind, etc.). Observable _ ❑Not Applicable C403.2.8 Thermally ineffective panel surfaces of ❑Complies [ME41]3 sensible heating panels have ❑Does Not insulation >= R-3.5. ❑Not Observable ❑Not Applicable �_ 403.3.1. Total cooling capacity without — _ - ❑Complies a economizers must be less than ❑Does Not [NA]0 %varMaxKBtuPerH%. ❑Not Observable ❑Not Applicable C403.2.7 Ducts and plenums sealed based on ❑Complies �[ME10]2 static pressure and location. ❑Does Not i ❑Not Observable --- _ -_ ❑Not Applicable- C403.2.7. 11.3 Ductwork operating >3 in. water _-- ❑Complies column requires air leakage testing. ❑Does Not [ME1I]3 ❑Not Observable ❑Not Applicable C408.2.2. Air outlets and zone terminal devices ❑Complies i 1 have means for air balancing. []Does Not s [ME53]3 ❑Not Observable ❑Not Applicable 6403.4.2 VAV fan motors >=7.5 hp to bed ❑Complies [ME66]2 by variable speed drive, have a vane- ❑Does Not axial fan with variable pitch blades, or ❑Not Observable have controls to limit fan motor demand. ❑Not Applicable C403.4.2 VAV fan motors >=7.5 hp to be driven ❑Complies [ME66]2 by variable speed drive, have a vane- ❑Does Not I axial fan with variable pitch blades, or ❑Not Observable have controls to limit fan motor ❑Not Applicable demand. IC403.4.2 VAV fan motors >=7.5 hp to be driven ❑Complies (ME66]2 by variable speed drive, have a vane- ❑Does Not axial fan with variable pitch blades, or ❑Not Observable have controls to limit fan motor ❑Not Applicable demand. 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) j 3 I Low Impact (Tier 3) Project Title: Liljenquist Apartments Report date: 03/03/17 Data filename: C:\Users\Dwayne 15\Documents\COMcheck\liljenquist mech.cck Page 5 of 9 # Mechanical Rough -in Inspection & Req.ID Complies? Comments/Assumptions C403.2.6 Exhaust air energy recovery on ❑Complies (ME57]1 systems meeting Table C403.2.6 ❑Does Not ❑Not Observable ❑Not Applicable C403.2.11 Unenclosed spaces that are heated ❑Complies JME71]2 use only radiant heat. ❑Does Not j ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) i 2Medium Impact (Tier 2) 3 ;Low Impact (Tier 3) Project Title: Liljenquist Apartments Report date: 03/03/17 Data filename: C:\Users\Dwayne 15\Documents\COMcheck\liljenquist mech.cck Page 6 of 9 Section # FinallnspectionComplies? Comments/Assumptions & Recl.ID I C403.2.4. Heating and cooling to each zone is ❑Complies j 1 controlled by a thermostat control. ❑Does Not [FI47]3 Minimum one humidity control device ❑Not Observable per installed humidification/dehumidification ❑Not Applicable j system. C403.2.4. Thermostatic controls have a 5 °F ❑Complies 12 deadband. ❑Does Not +[FI38]3 ❑Not Observable ❑Not Applicable C403.2.4. Temperature controls have setpoint ❑Complies 2 overlap restrictions. ❑Does Not I [F120]3 ❑Not Observable ❑Not Applicable C403.2.4. Each zone equipped with setback ❑Complies 3 controls using automatic time clock or ❑Does Not [FI39]3 programmable control system. ❑Not Observable ❑Not Applicable l C403.2.4. Automatic Controls: Setback to 55°F ❑Complies 3 (heat) and 85°F (cool); 7 -day clock, 2- ❑Does Not [F140]3 hour occupant override, 10 -hour ❑Not Observable backup ❑Not Applicable 0403.2.4. Systems include optimum start ❑Complies 3.3 controls. ❑Does Not [FI41]3 ❑Not Observable ❑Not Applicable C408.2.5. Furnished HVAC as -built drawings ❑Complies 1 submitted within 90 days of system ❑Does Not [F17]3 acceptance. ❑Not Observable ❑Not Applicable IC303.3, Furnished O&M manuals for HVAC ❑Complies C408.2.5. 13 systems within 90 days of system ❑Does Not �[F181 3 acceptance. ❑Not Observable ❑Not Applicable C408.2.5. An air and/or hydronic system ❑Complies 3 balancing report is provided for HVAC ❑Does Not JFI43I1 systems. ❑Not Observable ❑Not Applicable ;!C408.2.3. HVAC control systems have been ❑Complies 2 tested to ensure proper operation, ❑Does Not [FI10]1 calibration and adjustment of controls. ❑Not Observable ❑Not Applicable C404.3 Public lavatory faucet water ❑Complies [FI11]3 temperature <=110°F. ❑Does Not ❑Not Observable ❑Not Applicable C404.3 Public lavatory faucet water ❑Complies [FI11]3 temperature <=110'F. ❑Does Not ❑Not Observable ❑Not Applicable 1THigh Impact (Tier 1) 2 1Medium Impact (Tier 2) 3 ILow Impact (Tier 3) Project Title: Liljenquist Apartments Report date: 03/03/17 Data filename: C:\Users\Dwayne 15\Documents\COMcheck\liljenquist mech.cck Page 7 of 9 Section # Final Inspection Complies? Comments/Assumptions & Req.ID C404.5 First 8 ft of outlet piping is insulated ❑Complies [FI45]2 ❑Does Not ❑Not Observable ❑Not Applicable C404.5 First 8 ft of outlet piping is insulated ❑Complies [F145]2 ❑Does Not ❑Not Observable f ❑Not Applicable C403.2.2 HVAC systems and equipment ❑Complies [FI27]3 capacity does not exceed calculated ❑Does Not loads. ❑Not Observable ❑Not Applicable tC408.2.1 Commissioning plan developed by ❑Complies [F128]1 registered design professional or ❑Does Not approved agency. ❑Not Observable j ❑Not Applicable C408.2.4 Preliminary commissioning report ❑Complies [FI29]1 completed and certified by registered ❑Does Not design professional or approved ❑Not Observable agency. ❑Not Applicable I C408.2.5. Final commissioning report due to ❑Complies 14 building owner within 90 days of ❑Does Not [F130]1 receipt of certificate of occupancy. ❑Not Observable ❑Not Applicable jC408.2.3. HVAC equipment has been tested to ❑Complies 1 ensure proper operation. ❑Does Not [FI31]1 ❑Not Observable ❑Not Applicable C406 Efficient HVAC performance, efficient ❑Complies [FI34]1 lighting system, or on-site supply of ❑Does Not renewable energy consistent with ❑Not Observable what is shown the approved plans. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 I Medium Impact (Tier 2) 13 j Low Impact (Tier 3) Project Title: Liljenquist Apartments Report date: 03/03/17 Data filename: C:\Users\Dwayne 15\Documents\COMcheck\liljenquist mech.cck Page 8 of 9 Project Title: Liljenquist Apartments Report date: 03/03/17 Data filename: C:\Users\Dwayne 15\Documents\COMcheck\liljenquist mech.cck Page 9 of 9