HomeMy WebLinkAboutBUILDING REVIEW 4-25-17 - 17-00145 - 366 Dividend Dr - Monkey Bars - AdditionReview Report Current Building Review Status: REVISIONS Application Number: 17-00145Permit Details Application Received Date: 03/27/2017 Commercial Addition Application Approved Date: Application Approved Status: APPROVED 03/27/2017 366 Dividend Dr Monkey Bars - Addition Status of Plan Reviews Completed 03/28/2017Electrical Review REVISIONS 03/28/2017Public Works Review - Site Plan REVISIONS 03/29/2017Planning and Zoning Review - Site Plan REVISIONS 03/29/2017Fire Department Review - Site Plan N/A 03/29/2017Building Review REVISIONS 03/30/2017Electrical Review COMPLETED 04/03/2017Plumbing Review COMPLETED 04/03/2017HVAC Review REVISIONS 04/03/2017Planning and Zoning Review - Site Plan REVISIONS 04/03/2017Planning and Zoning Review - Site Plan REVISIONS 04/25/2017Building Review REVISIONS Permit Review Status Plan Reviews Still in Progress Public Works Review - Site Plan HVAC Review Planning and Zoning Review - Site Plan Building Review DESCRIPTION COMMENTS STA TUS *Please respond to "REVISIONS" status items, with appropriate comment/documentation as needed! Mixed use occupancies meet the requirements of IBC Section 508 and Table 508.4 REVISIONSThe existing building was approved as V-B construction (non-separated mixed use). Sprinkler system was used to allow area increase based on V-B construction. With no separation required to the addition, show how the entire building meets allowable area of a mixed occupancy. *Revisions Response : Combustible materials in Type I & Type II bldgs meet req. of IBC Sect. 603 REVISIONSIf the addition can be considered II-B construction without separation, combustible materials are not allowed except as permitted by section 603. How does the wood framing comply with this portion of building. *Revisions Response : Reviewed By: Quinton Owens Review Date: 04/25/2017 Plan Review Details quinton.owens@rexburg.org Building Review Status: REVISIONS Page 1 of 2 Approval of plans does not constitue approval of variance from code Building Review (Continued) D ESCRIPTIO N CO MMEN TS STATUS Fire walls meet the requirements of IBC Section 706 REVISIONSFire wall may be required for building to meet allowable area. *Revisions Response : Ventilation is provided as per IBC Section 1203 REVISIONSHow is ventilation provided per IBC Section 1203? Openings are less than 4% of floor area. *Revisions Response : Building complies with IECC (IBC, 1301)REVISIONSNo energy report submitted. *Revisions Response : Special Inspection Contractor is identified Identify special inspector prior to building construction. COMPLETED Geotech Insp. is provided or Bldg. Off. has waived reqs. as per IBC Sec. 1803 Only 1500 psi assumed. If soil conditions are questionable, special inspection may be required. COMPLETED Page 2 of 2 Approval of plans does not constitue approval of variance from code