HomeMy WebLinkAboutREVIEW REPORT - 17-00165 - 244 Jefferson Dr - SFRReview
Report
Current Residential Building Review Status: REVISIONS
Application Number: 17-00165Permit Details
Application Received Date: 04/03/2017
Building - Single Family Residence
Application Approved Date:
Application Approved Status: APPW/EXCP
04/03/2017
244 Jefferson Dr
244 Jefferson Dr - SFR
Status of Plan Reviews Completed
04/10/2017Planning and Zoning Review COMPLETED
04/10/2017Residential Building Review REVISIONS
Permit Review Status
Plan Reviews Still in Progress
Residential Building Review
DESCRIPTION COMMENTS STA TUS
*Please respond to "REVISIONS" status items, with appropriate comment/documentation as needed!
Single Family Residential YES
Section showing construction details REVISIONSProvide sectional showing construction details,
footing up to the roof
*Revisions Response :
Truss Calculation Sheets REVISIONSHave on site when the framing inspection is
done
*Revisions Response :
Floor Joist Details REVISIONSProvide TJI expert drawing on or before the
framing inspection
*Revisions Response :
Plans match quantities & values on a "passing"
RES check compliance report
REVISIONSProvide res/check
*Revisions Response :
Proper Size (per Tbl. 403.1, use 1500 psf unless
soil type is know, Tbl 401.4.1
REVISIONSSpecify footing size
*Revisions Response :
Flood Plain NO
1/2" Anchor bolts with 3" x 3" x 1/4" square
washers
FAILEngineer to specify size and spacing.
Foundation walls w/ rebar (city ordinance)COMPLETED
Reviewed By: Ted Dye
Review Date: 04/10/2017
Plan Review Details
ted.dye@rexburg.org
Residential Building Review Status: REVISIONS
Page 1 of 4
Approval of plans does not constitue approval of variance from code
Residential Building Review (Continued)
D ESCRIPTIO N CO MMEN TS STATUS
Damp proofing/Waterproofing to finish grade COMPLETED
Crawl space access of 18" x 24" min. R408.3 COMPLETED
Crawl Space Ventilation/insulation = 1 sf vent per
150 sq. ft.
COMPLETED
Grading slope away from house. R401.3 COMPLETED
Floor/Foundation Plan See notes on plans.COMPLETED
All Building Elevations COMPLETED
Design Criteria (identified on plans as Wind-85
mph, Snow-35 lb./sq. ft.)
COMPLETED
Plot Plan COMPLETED
To Scale Not to scale COMPLETED
Legible Hard to read, took more time than normal to
work through the plans.
COMPLETED
Gas appliances not in bedrooms, bath., toilet
rooms, or storage closets G2406.2
COMPLETED
Rm acc. 36"min width/Attic Acc. clear ope.
20x30/Und flr r.o 22x30 M306.2;
COMPLETED
Dyer Vent length 35' max w/8' transition (-5 per
90 deg turns) M504.6.41
COMPLETED
Half openable 3sf window or Mech. Ventilation in
bathrooms . . .
COMPLETED
One room at least 120 sf COMPLETED
Smoke Alarms (each bedroom and common area
and 1 on each level) R314
COMPLETED
Front set back (32 ft. from curb)COMPLETED
60% minimum of front yard green COMPLETED
Rear set back (LDR1 25 ft. & LDR2 20 ft.)COMPLETED
Sides set backs(6" for every ft. of bldg. height
with LDR-7.5' min., & LDR1-6')
COMPLETED
Building-Height (max. 30 ft.)COMPLETED
Page 2 of 4
Approval of plans does not constitue approval of variance from code
Residential Building Review (Continued)
D ESCRIPTIO N CO MMEN TS STATUS
Rebar (2-#4 continuous)COMPLETED
Footing Depth(36" below fin. grade and 12"
below undist. soil; 18" to top of sl
COMPLETED
Seismic Hold Downs and Braced wall Panels
(R602.10)
See plans for hold down size in #'s COMPLETED
Floors joists sized as per R502.3, Wood I-joists
sized per manufr.
COMPLETED
Joists Under Load Bearing Partitions shall be
doubled. R502.4
COMPLETED
Girders sized per R502.5 or per manufr. Tables
for engineered products
COMPLETED
Floor Sheathing (3/4" min for joists, 24" oc & 5/8
for joists 16") R503.2.2
COMPLETED
Wall(bearing and nonbearing)stud sizes, hght &
spacing per Tbl 602.3(5) R602.3
COMPLETED
Headers in Bearing Wall designed as per Tables
502.5(1&2) R602.7
COMPLETED
Roof Trusses (desidgned acc. R802.10.1) 35#
Snow and 90 mph winds (local cond.)
COMPLETED
Rafter and Truss tie-downs R802.10.5 COMPLETED
Attic Access 22" x 30" min. opening R807 COMPLETED
Masonry & stucco:weather resistive barrier over
ext. sheathing R703.2 & . . .
COMPLETED
Roof Ventilation as per R806 COMPLETED
Asphalt Shingles(slp>2:12) w/ice protection or
Other type to comply w/R905
COMPLETED
Garage/House drywall separ.(protect ext.
walls&beams support. hab. space) 302.6
COMPLETED
Door fr Garage-House(1 3/8" solid wd/steel door
or 20 min. fire-rat. dor R309.1
COMPLETED
House Numbers R321 COMPLETED
Interior and exterior stair illumination shall
comply with R303.6
COMPLETED
Page 3 of 4
Approval of plans does not constitue approval of variance from code
Residential Building Review (Continued)
D ESCRIPTIO N CO MMEN TS STATUS
Bathroom Fixture clearances comply with Figure
R307.2
COMPLETED
Other habitable rooms 70 sf min w/ a min.
dimension of 7 ft. R304
COMPLETED
Emergency Egress in all sleeping rooms and
basements w/ habitable space R310
COMPLETED
One required Exit Door shall comply with 2311.2 COMPLETED
Landings at top/bottom of stairway R311.7.5 &
each side of each ext. door R311.3
COMPLETED
Stair Rise/Run (7 3/4' max. rise & 10" min. tread,
nosing req'd if <11")
COMPLETED
Stair width (36' min)COMPLETED
Vapor retarder on warm in winter side of walls,
ceiling and floors R601.3
COMPLETED
*Water Heater heat traps IECC 504.7 COMPLETED
Duct sealing and insulation N1103.3&4 or IECC
503.3.3.3, 503.3.3.4.3
COMPLETED
Page 4 of 4
Approval of plans does not constitue approval of variance from code
Review
Report
Current Planning and Zoning Review Status: APPROVED
Application Number: 17-00165Permit Details
Application Received Date: 04/03/2017
Building - Single Family Residence
Application Approved Date:
Application Approved Status: APPW/EXCP
04/03/2017
244 Jefferson Dr
244 Jefferson Dr - SFR
Status of Plan Reviews Completed
04/10/2017Planning and Zoning Review COMPLETED
04/10/2017Residential Building Review REVISIONS
Permit Review Status
Plan Reviews Still in Progress
Residential Building Review
Reviewed By: Ted Dye
Review Date: 04/10/2017
Plan Review Details
ted.dye@rexburg.org
Planning and Zoning Review Status: APPROVED
Page 1 of 1
Approval of plans does not constitue approval of variance from code