HomeMy WebLinkAboutRESCHECK - 17-00165 - 244 Jefferson Dr - SFRCREScheck Software Version 4.6.4 �J( Compliance Certificate Project Harrop Residence Energy Code: 2009 IECC Location: Rexburg, Idaho Construction Type: Single-family Project Type: New Construction Orientation: Bldg. faces 180 deg. from North Conditioned Floor Area: 2,053 ft2 Glazing Area 10% Climate Zone: 6 (8693 HDD) Permit Date: 72 Permit Number: 3 Construction Site: Lot 7 Block 7 Founders Square Phase 1 Rexburg, ID 83442 Owner/Agent: Kieth Harrop Sugar City, ID 217-412-4430 aliceannha rrop@comcast. net Designer/Contractor: William Sharp South Fork Design Group, LLC 1066 N Yellowstone Hwy Rexburg, ID 83440 208-852-6236 will@southforkengineering.com Compliance: Passes using UA trade-off Compliance: 10.7% Better Than Code Maximum UA: 420 Your UA: 375 The % Better or Worse Than Code Index reflects how close to compliance the house is based an code tradeoff rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home. Envelope Assemblies Wall 1: Wood Frame, 16" o.c. 608 21.0 Orientation: Front 3 Window 4: Vinyl/Fiberglass Frame:Double Pane with Low -E 16 Orientation: Front 5 Window 7: Vinyl/Fiberglass Frame:Double Pane with Law -E 16 Orientation: Front 13 Window 9: Vinyl/Fiberglass Frame:Dcuble Pane with Low -E 25 Orientation: Front 25 Door 5: Solid 72 Orientation: Front 3 Door 6: Solid 72 Orientation: Front Door 7: Glass 30 Orientation: Front Wall 2: Wood Frame, 16" o.c. 608 21.0 Orientation: Back Window 10: Vinyl/Fiberglass Frame:Double Pane with Low -E 15 Orientation: Unspecified Window 10: Vinyl/Fiberglass Frame:Double Pane with Low -E 15 Orientation: Unspecified Window 10: Vinyl/Fiberglass Frame:Double Pane with Low -E 15 Orientation: Unspecified Project Title: Harrop Residence Data filename: D:\Dropbox\06 Clients Will\2016\001 Finished Jobs\Harrop Residence\Harrop Rescheck.rck 0.0 0.057 21 0.180 3 0.180 3 0.180 5 0.180 13 0.180 13 0.180 5 0.0 0.057 25 0.180 3 0.180 3 0.180 3 Report date: 04/11/17 Page 1 of 8 Window 10: Vinyl/Fiberglass Frame:Double Pane with Low -E 15 0.180 3 Orientation: Unspecified Window 10: Vinyl/Fiberglass Frame:Double Pane with Low -E 12 0.180 2 Orientation: Unspecified Door 8: Solid 18 0.180 3 Orientation: Unspecified Door 9: Glass 36 0.180 6 Orientation: Unspecified Door 10: Solid 48 0.180 9 Orientation: Unspecified Wall 3: Wood Frame, 16" o.c. 480 21.0 0.0 0.057 25 Orientation: Right side Window 10: Vinyl/Fiberglass Frame:Double Pane with Low -E 16 0.180 3 Orientation: Unspecified Door 10: Solid 18 0.180 3 Orientation: Unspecified Wall 4: Wood Frame, 16" o.c. 480 21.0 0.0 0.057 27 Orientation: Left side Window 10: Vinyl/Fiberglass Frame:Double Pane with Low -E 6 0.180 1 Orientation: Unspecified Window 11: Vinyl/Fiberglass Frame:Double Pane with Low -E 9 0.180 2 Orientation: Unspecified Ceiling 1: Flat Ceiling or Scissor Truss 2,053 50.0 0.0 0.026 53 Crawl 1: Solid Concrete or Masonry 304 5.0 0.0 0.137 26 Wall height: 4.0' Depth below grade: 3.5' Insulation depth: 4.0' Crawl 2: Solid Concrete or Masonry 304 5.0 0.0 0.137 26 Wall height: 4.0' Depth below grade: 3.5' Insulation depth: 4.0' Crawl 3: Solid Concrete or Masonry 216 5.0 0.0 0.137 18 Wall height: 4.0' Depth below grade: 3.5' Insulation depth: 4.0' Crawl 4: Solid Concrete or Masonry 216 5.0 0.0 0.137 18 Wall height: 4,0' Depth below grade: 3.5' Insulation depth: 4.0' Floor 1: All -Wood Joist/Truss:Over Unconditioned Space 2,053 38.0 0.0 0.026 53 Compliance Statement: The proposed building design described here Is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in REScheck Version 4.6.4 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Date Name - Title Signature Project Title: Harrop Residence Report date: 04/11/17 Data filename: D:\Dropbox\06 Clients Will\2016\001 Finished Jobs\Harrop Residence\Harrop Page 2 of 8 Rescheck.rck REScheck Software Version 4.6.4 fZInspection Checklist Energy Code: 2009 IECC Requirements: 100.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Pre-Inspection/Plan Review Plans Vered Vaiue Field Verified Vaiue Complies? Comments/Assumptions & Re .ID 103.2 Construction drawings and ❑Complies Requirement will be met. [PR111 documentation demonstrate ❑Does Not energy code compliance for the ❑Not Observable building envelope. _ <' E]Not Applicable 103.2, Construction drawings and 's❑Complies Requirement will be met. 403.7 documentation demonstrate , "❑Does Not [PR3j1 energy code compliance for lighting and mechanical systems.❑Not Observable Systems serving multiple r ❑Not Applicable dwelling units must demonstrate;' compliance with the commercial 403.6 Heating and cooling equipment is ! Heating: Heating: ❑Complies Requirement will be met. [PR2 jl sized per ACCA Manual S based Btu/hr— Btu/hr ❑Does Not U on loads per ACCA Manual J or other approved methods. Cooling:Cooling: ❑Not Observable Btu/hr— . Btu/hr— ❑Not Applicable Additional Comments/Assumptions: 11 High Impact (Tier 1) Jfofl Medium Impact (Tier 2) TFL Impact (Tier 3) Project Title: Harrop Residence Report date: 04/11/17 Data filename: D:\Dropbox\06 Clients Will\2016\001 Finished Jobs\Harrop Residence\Harrop Page 3 of 8 Rescheck.rck __._. _. T Section # Plans Verified Foundation Inspection Value Field Verified Value Complies? Comments/Assumptions & Req.ID 402.2.9 Unvented crawl space wall R- R-_ ❑Complies See the Envelope Assemblies [F0711 insulation R -value. R- R- L1 Does Not table for values. ❑Not Observable, ❑Not Applicable, 303.2 Unvented crawl space wall ❑Complies ,Requirement will be met. [F08]1 'insulation installed per ❑Does Not to manufacturer's instructions. -,❑Not Observable' Applicable 402.2.9 __ Unvented crawl space continuous _.❑Not ❑Complies (Requirement will be met. (F0911 vapor retarder installed over El Does Not exposed earth, joints overlapped ❑Not Observable by 6 in. and sealed, extending at least 6 in. up and attached to the El Not Applicable wall. 402.2.9 Unvented crawl space wall in. _ in, '❑Complies 'See the Envelope Assemblies [FO10]1 insulation depth of burial or ❑Does Not table for values. O, distance from top of wall. ❑Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies Requirement will be met. [F011)2 to protect exposed exterior ❑Does Not M insulation and extends a minimum of 6 in. below grade. ❑Not Observable ❑Not Applicable 403.8 Snow- and ice -melting system ❑Complies Requirement will be met. [FO12]1 controls installed. El Does Not [ -]Not Observable ❑Not Applicable. Additional Comments/Assumptions: 1I High Impact (Tier 1) } Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3) Project Title: Harrop Residence Report date: 04/11/17 Data filename: D:\Dropbox\06 Clients Will\2016\001 Finished Jobs\Harrop Residence\Harrop Page 4 of 8 Rescheck.rck Section - — -- # Framing / Rough -In Inspection Plans Verified Value Field Verified Value Complies? Comments/Assumptions & Req.ID 402.1.1, Door U -factor. U-- U- ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FRI]' []Not Observable a ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U-_ U-- ❑Complies Seethe Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.5 : ❑Not Observable [FR2]1 ❑Not Applicable 303.1.3 U -factors of fenestration products -❑Complies Requirement will be met. [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or ❑Not Observable taken from the default table. ❑Not Applicable 402.4.4 Fenestration that is not site built ❑Complies Requirement will be met. [FR20]1 is listed and labeled as meeting ,. < ❑Does Not 0 AAMA/WDMA/CSA 101/I.S.2/A440 ❑Not Observable or has infiltration rates per NFRC ❑Not Applicable 400 that do not exceed code limits. 402.4.5 IC -rated recessed lighting fixtures ❑Complies Requirement will be met. [FR16]2 'sealed at housing/interior finish ❑Does Not U and labeled to indicate <_2.0 cfm ❑Not Observable leakage at 75 Pa. ❑Not Applicable 403.2.1 Supply ducts In attics are R- R- ❑Complies Requirement will be met. [FR12]1 insulated to >_R-8. All other ducts R- R- ❑Does Not in unconditioned spaces or — ❑Not Observable outside the building envelope are insulated to >_R-6. ❑Not Applicable 403.2.2 All joints and seams of air ducts, ❑Complies Requirement will be met. [FR13]1 air handlers, filter boxes, and El Does Not building cavities used as return ❑Not Observable ducts are sealed. ❑Not Applicable 403.2.3 Building cavities are not used for ❑Complies Requirement will be met. [FR15)3 supply ducts. ❑Does Not 9:: EJ Not Observable ❑Not Applicable 403.3 HVAC piping conveying fluids R-- R-_ ❑Complies Requirement will be met. (FR17]2 above 105 QF or chilled fluids El Does Not ,u below 55 QF are insulated to >_R- E] Not Observable 3. ❑Not Applicable 403.4 Circulating service hot water R-- R-_ ❑Complies Requirement will be met. [FR18]' pipes are insulated to R-2. ❑Does Not ❑Not Observable ❑Not Applicable 403.5 Automatic or gravity dampers are ❑Complies Requirement will be met. (FR19)2 installed on all outdoor air;� cc ❑Does Not 'J intakes and exhausts. El Not Observable ❑Not Applicable Additional Comments/Assumptions: 111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13'1 Low Impact (Tier 3) Project Title: Harrop Residence Report date: 04/11/17 Data filename: D:\Dropbox\06 Clients Wi11\2016\001 Finished Jobs\Harrop Residence\Harrop Page 5 of R Rescheck.rck Section # Insulation Inspection Plans Verified Value Field Verified Value Complies? Comments/Assumptions & Req.ID 303.1 All installed insulation is labeled _ ❑Complies Requirement will be met. [IN13]2 or the installed R-values ❑Does Not -v provided. []Not Observable ' ❑Not Applicable 402.1.1, Floor Insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.5, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 [IN1II ❑ Steel ❑ Steel ❑Not Observable 0 ❑Not Applicable 303.2, Floor insulation installed per ❑Complies Requirement will be met. 402.2.6 manufacturer's instructions, and EJ Does Not [IN211 in substantial contact with the to underside of the subfloor.❑Not ❑Not Observable Applicable, 402.1.1, Wall insulation R-value. If this is a R- R-_ ❑Complies 'See the Envelope Assemblies 402.2.4, mass wall with at least 1h of the ❑ Wood ❑ Wood ❑Does Not 'table for values. 402.2.5 [IN311 wall insulation on the wall exterior, the exterior insulation ❑ Mass ❑ Mass [--]Not Observable 0' requirement applies. ❑Steel ❑Steel ❑Not Applicable. 303.2 Wall insulation Is installed per ❑Complies Requirement will be met. [IN411 manufacturer's instructions. .❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact (Tier 1) Wfl Medium Impact (Tier 2) B 1 Low Impact (Tier 3) Project Title: Harrop Residence Report date: 04/11/17 Data filename: D:\Dropbox\06 Clients Will\2016\001 Finished Jobs\Harrop Residence\Harrop Page 6 of 8 Rescheck.rck Section # Final Inspection Provisions Plans Verified Value Field Verified Value Complies? - -- Comments/Assumptions & Req.ID 402.1.1, Ceiling insulation R -value. Where R- R-_ ❑Complies See the Envelope Assemblies 402.2.1, > R-30 is required, R-30 can be ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2 [Fill' used if insulation is not compressed at eaves. R-30 may ❑ Steel ❑ Steel .❑Not Observable � be used for 500 ft° or 20%❑Not Applicable (whichever is less) where sufficient space is not available. 303.1.1.1, Ceiling insulation Installed per ❑Complies Requirement will be met. 303.2 manufacturer's instructions. ❑Does Not (FI211 Blown Insulation marked every 300 ft'. ❑Not Observable ❑Not Applicable 402.2.3 (Attic access hatch and door R- R-_ ❑Complies'. Requirement will be met. [F1311 Insulation aR-value of the ❑Does Not � adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.2, Building envelope tightness ACH 50 =_ ACH 50 =_ ❑Complies Requirement will be met. 402.4.2.1 verified by blower door test result) ❑Does Not [FI1711 of <7 ACH at 50 Pa. This - ❑Not Observable requirement may instead be met via visual inspection, In which ❑Not Applicable case verification may need to occur during Insulation Inspection. 403.2.2 Post construction duct tightness_ cfm _ cfm [Complies' Requirement will be met. [F1411 test result of s8 cfm to outdoors, . ❑Does Not or s12 cfm across systems. Or,❑Not rough -in test result of s6 cfm Observable', across systems or s4 cfm ❑Not Applicable without air handler. Rough -in test. verification may need to occur during Framing Inspection. 403.1.1 Programmable thermostats - ❑Complies Requirement will be met. [FI932 installed on forced air furnaces ' 3❑Does Not ❑Not Observable ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies Requirement will be met. [F[10]2 on heat pumps. ❑Does Not 'J ❑Not Observable ❑Not Applicable 403.4 Circulating service hot water„,...: ❑Complies Requirement will be met. (1`11112 systems have automatic or❑Does Not J accessible manual controls.❑Not Observable ❑Not Applicable 404.1 50% of lamps in permanent ❑Complies Requirement will be met. [FI611 fixtures are high efficacy lamps. ❑Does Not 9 ❑Not Observable ❑Not Applicable 401.3 Compliance certificate posted❑Complies .❑Does Requirement will be met. [F]7] �.'. Not as ❑Not Observable ❑Not Applicable. 303.3 Manufacturer manuals for :.. ❑Complies Requirement will be met. [FI18]' mechanical and water heating P,wsR.", ❑Does Not equipment have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact (Tier 1) 2'1 Medium Impact (Tier 2) T3 Low Impact (Tier 3) Project Title: Harrop Residence Report date: 04/11/17 Data filename: D:\Dropbox\06 Clients Will\2016\001 Finished Jobs\Harrop Residence\Harrop Page 7 of 8 Rescheck.rck 1 J High Impact (Tier 1) 12 1 Medium impact( 2) 3 Low Impact (Tier 3) Project Title: Harrop Residence Report date: 04/11/17 Data filename: D:\Dropbox\06 Clients Wi11\2016\001 Finished jobs\Harrop Residence\Harrop Page 8 of 8 Rescheck.rck �(2009 IECC Energy j Efficiency Certificate Above -Grade Wall 21.00 Below -Grade Wall 5.00 Floor 38.00 Ceiling / Roof 50.00 Ductwork (unconditioned spaces): Window 0.18 Door 0.18 Heating System: Cooling System:_ Water Heater: Name: Date: Comments