�J( Compliance Certificate
Project Harrop Residence
Energy Code:
2009 IECC
Location:
Rexburg, Idaho
Construction Type:
Single-family
Project Type:
New Construction
Orientation:
Bldg. faces 180 deg. from North
Conditioned Floor Area:
2,053 ft2
Glazing Area
10%
Climate Zone:
6 (8693 HDD)
Permit Date:
72
Permit Number:
3
Construction Site:
Lot 7 Block 7
Founders Square Phase 1
Rexburg, ID 83442
Owner/Agent:
Kieth Harrop
Sugar City, ID
217-412-4430
aliceannha rrop@comcast. net
Designer/Contractor:
William Sharp
South Fork Design Group, LLC
1066 N Yellowstone Hwy
Rexburg, ID 83440
208-852-6236
will@southforkengineering.com
Compliance: Passes using UA trade-off
Compliance: 10.7% Better Than Code Maximum UA: 420 Your UA: 375
The % Better or Worse Than Code Index reflects how close to compliance the house is based an code tradeoff rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home.
Envelope Assemblies
Wall 1: Wood Frame, 16" o.c.
608 21.0
Orientation: Front
3
Window 4: Vinyl/Fiberglass Frame:Double Pane with Low -E
16
Orientation: Front
5
Window 7: Vinyl/Fiberglass Frame:Double Pane with Law -E
16
Orientation: Front
13
Window 9: Vinyl/Fiberglass Frame:Dcuble Pane with Low -E
25
Orientation: Front
25
Door 5: Solid
72
Orientation: Front
3
Door 6: Solid
72
Orientation: Front
Door 7: Glass
30
Orientation: Front
Wall 2: Wood Frame, 16" o.c.
608 21.0
Orientation: Back
Window 10: Vinyl/Fiberglass Frame:Double Pane with Low -E
15
Orientation: Unspecified
Window 10: Vinyl/Fiberglass Frame:Double Pane with Low -E
15
Orientation: Unspecified
Window 10: Vinyl/Fiberglass Frame:Double Pane with Low -E
15
Orientation: Unspecified
Project Title: Harrop Residence
Data filename: D:\Dropbox\06 Clients Will\2016\001 Finished Jobs\Harrop Residence\Harrop
Rescheck.rck
0.0 0.057
21
0.180
3
0.180
3
0.180
5
0.180
13
0.180
13
0.180
5
0.0 0.057
25
0.180
3
0.180
3
0.180
3
Report date: 04/11/17
Page 1 of 8
Window 10: Vinyl/Fiberglass Frame:Double Pane with Low -E
15
0.180
3
Orientation: Unspecified
Window 10: Vinyl/Fiberglass Frame:Double Pane with Low -E
12
0.180
2
Orientation: Unspecified
Door 8: Solid
18
0.180
3
Orientation: Unspecified
Door 9: Glass
36
0.180
6
Orientation: Unspecified
Door 10: Solid
48
0.180
9
Orientation: Unspecified
Wall 3: Wood Frame, 16" o.c.
480
21.0 0.0
0.057
25
Orientation: Right side
Window 10: Vinyl/Fiberglass Frame:Double Pane with Low -E
16
0.180
3
Orientation: Unspecified
Door 10: Solid
18
0.180
3
Orientation: Unspecified
Wall 4: Wood Frame, 16" o.c.
480
21.0 0.0
0.057
27
Orientation: Left side
Window 10: Vinyl/Fiberglass Frame:Double Pane with Low -E
6
0.180
1
Orientation: Unspecified
Window 11: Vinyl/Fiberglass Frame:Double Pane with Low -E
9
0.180
2
Orientation: Unspecified
Ceiling 1: Flat Ceiling or Scissor Truss
2,053
50.0 0.0
0.026
53
Crawl 1: Solid Concrete or Masonry
304
5.0 0.0
0.137
26
Wall height: 4.0'
Depth below grade: 3.5'
Insulation depth: 4.0'
Crawl 2: Solid Concrete or Masonry
304
5.0 0.0
0.137
26
Wall height: 4.0'
Depth below grade: 3.5'
Insulation depth: 4.0'
Crawl 3: Solid Concrete or Masonry
216
5.0 0.0
0.137
18
Wall height: 4.0'
Depth below grade: 3.5'
Insulation depth: 4.0'
Crawl 4: Solid Concrete or Masonry
216
5.0 0.0
0.137
18
Wall height: 4,0'
Depth below grade: 3.5'
Insulation depth: 4.0'
Floor 1: All -Wood Joist/Truss:Over Unconditioned Space
2,053
38.0 0.0
0.026
53
Compliance Statement: The proposed building design described here Is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to
meet the 2009 IECC requirements in
REScheck Version 4.6.4 and to comply with the mandatory requirements listed
in the REScheck
Inspection Checklist.
Date
Name - Title Signature
Project Title: Harrop Residence Report date: 04/11/17
Data filename: D:\Dropbox\06 Clients Will\2016\001 Finished Jobs\Harrop Residence\Harrop Page 2 of 8
Rescheck.rck
REScheck Software Version 4.6.4
fZInspection Checklist
Energy Code: 2009 IECC
Requirements: 100.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
#
Pre-Inspection/Plan Review
Plans Vered
Vaiue
Field Verified
Vaiue
Complies?
Comments/Assumptions
& Re .ID
103.2
Construction drawings and
❑Complies
Requirement will be met.
[PR111
documentation demonstrate
❑Does Not
energy code compliance for the
❑Not Observable
building envelope.
_
<'
E]Not Applicable
103.2,
Construction drawings and
's❑Complies
Requirement will be met.
403.7
documentation demonstrate
,
"❑Does
Not
[PR3j1
energy code compliance for
lighting and mechanical systems.❑Not
Observable
Systems serving multiple
r
❑Not Applicable
dwelling units must demonstrate;'
compliance with the commercial
403.6
Heating and cooling equipment is
! Heating:
Heating:
❑Complies
Requirement will be met.
[PR2 jl
sized per ACCA Manual S based
Btu/hr—
Btu/hr
❑Does Not
U
on loads per ACCA Manual J or
other approved methods.
Cooling:Cooling:
❑Not Observable
Btu/hr—
. Btu/hr—
❑Not Applicable
Additional Comments/Assumptions:
11 High Impact (Tier 1) Jfofl Medium Impact (Tier 2) TFL Impact (Tier 3)
Project Title: Harrop Residence Report date: 04/11/17
Data filename: D:\Dropbox\06 Clients Will\2016\001 Finished Jobs\Harrop Residence\Harrop Page 3 of 8
Rescheck.rck
__._.
_. T
Section
#
Plans Verified
Foundation Inspection Value
Field Verified
Value Complies?
Comments/Assumptions
& Req.ID
402.2.9
Unvented crawl space wall R-
R-_ ❑Complies
See the Envelope Assemblies
[F0711
insulation R -value. R-
R- L1 Does Not
table for values.
❑Not Observable,
❑Not Applicable,
303.2
Unvented crawl space wall
❑Complies
,Requirement will be met.
[F08]1
'insulation installed per
❑Does Not
to
manufacturer's instructions.
-,❑Not Observable'
Applicable
402.2.9
__
Unvented crawl space continuous
_.❑Not
❑Complies
(Requirement will be met.
(F0911
vapor retarder installed over
El Does Not
exposed earth, joints overlapped
❑Not Observable
by 6 in. and sealed, extending at
least 6 in. up and attached to the
El Not Applicable
wall.
402.2.9
Unvented crawl space wall in.
_ in, '❑Complies
'See the Envelope Assemblies
[FO10]1
insulation depth of burial or
❑Does Not
table for values.
O,
distance from top of wall.
❑Not Observable
❑Not Applicable
303.2.1
A protective covering is installed
❑Complies
Requirement will be met.
[F011)2
to protect exposed exterior
❑Does Not
M
insulation and extends a
minimum of 6 in. below grade.
❑Not Observable
❑Not Applicable
403.8
Snow- and ice -melting system
❑Complies
Requirement will be met.
[FO12]1
controls installed.
El Does Not
[ -]Not Observable
❑Not Applicable.
Additional Comments/Assumptions:
1I High Impact (Tier 1) } Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3)
Project Title: Harrop Residence Report date: 04/11/17
Data filename: D:\Dropbox\06 Clients Will\2016\001 Finished Jobs\Harrop Residence\Harrop Page 4 of 8
Rescheck.rck
Section
- — --
#
Framing / Rough -In Inspection
Plans Verified
Value
Field Verified
Value Complies?
Comments/Assumptions
& Req.ID
402.1.1,
Door U -factor.
U--
U- ❑Complies
See the Envelope Assemblies
402.3.4
❑Does Not
table for values.
[FRI]'
[]Not Observable
a
❑Not Applicable
402.1.1,
Glazing U-factor(area-weighted
U-_
U-- ❑Complies
Seethe Envelope Assemblies
402.3.1,
average).
❑Does Not
table for values.
402.3.3,
402.5
:
❑Not Observable
[FR2]1
❑Not Applicable
303.1.3
U -factors of fenestration products
-❑Complies
Requirement will be met.
[FR4]1
are determined in accordance
❑Does Not
with the NFRC test procedure or
❑Not Observable
taken from the default table.
❑Not Applicable
402.4.4
Fenestration that is not site built
❑Complies
Requirement will be met.
[FR20]1
is listed and labeled as meeting
,. <
❑Does Not
0
AAMA/WDMA/CSA 101/I.S.2/A440
❑Not Observable
or has infiltration rates per NFRC
❑Not Applicable
400 that do not exceed code
limits.
402.4.5
IC -rated recessed lighting fixtures
❑Complies
Requirement will be met.
[FR16]2
'sealed at housing/interior finish
❑Does Not
U
and labeled to indicate <_2.0 cfm
❑Not Observable
leakage at 75 Pa.
❑Not Applicable
403.2.1
Supply ducts In attics are
R-
R- ❑Complies
Requirement will be met.
[FR12]1
insulated to >_R-8. All other ducts
R-
R- ❑Does Not
in unconditioned spaces or
—
❑Not Observable
outside the building envelope are
insulated to >_R-6.
❑Not Applicable
403.2.2
All joints and seams of air ducts,
❑Complies
Requirement will be met.
[FR13]1
air handlers, filter boxes, and
El Does Not
building cavities used as return
❑Not Observable
ducts are sealed.
❑Not Applicable
403.2.3
Building cavities are not used for
❑Complies
Requirement will be met.
[FR15)3
supply ducts.
❑Does Not
9::
EJ Not Observable
❑Not Applicable
403.3
HVAC piping conveying fluids
R--
R-_ ❑Complies
Requirement will be met.
(FR17]2
above 105 QF or chilled fluids
El Does Not
,u
below 55 QF are insulated to >_R-
E] Not Observable
3.
❑Not Applicable
403.4
Circulating service hot water
R--
R-_ ❑Complies
Requirement will be met.
[FR18]'
pipes are insulated to R-2.
❑Does Not
❑Not Observable
❑Not Applicable
403.5
Automatic or gravity dampers are
❑Complies
Requirement will be met.
(FR19)2
installed on all outdoor air;�
cc
❑Does Not
'J
intakes and exhausts.
El Not Observable
❑Not Applicable
Additional Comments/Assumptions:
111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13'1 Low Impact (Tier 3)
Project Title: Harrop Residence Report date: 04/11/17
Data filename: D:\Dropbox\06 Clients Wi11\2016\001 Finished Jobs\Harrop Residence\Harrop Page 5 of R
Rescheck.rck
Section
#
Insulation Inspection
Plans Verified
Value
Field Verified
Value
Complies?
Comments/Assumptions
& Req.ID
303.1
All installed insulation is labeled
_
❑Complies
Requirement will be met.
[IN13]2
or the installed R-values
❑Does Not
-v
provided.
[]Not Observable
'
❑Not Applicable
402.1.1,
Floor Insulation R-value.
R-
R-
❑Complies
See the Envelope Assemblies
402.2.5,
❑ Wood
❑ Wood
❑Does Not
table for values.
402.2.6
[IN1II
❑ Steel
❑ Steel
❑Not Observable
0
❑Not Applicable
303.2,
Floor insulation installed per
❑Complies
Requirement will be met.
402.2.6
manufacturer's instructions, and
EJ Does Not
[IN211
in substantial contact with the
to
underside of the subfloor.❑Not
❑Not Observable
Applicable,
402.1.1,
Wall insulation R-value. If this is a
R-
R-_
❑Complies
'See the Envelope Assemblies
402.2.4,
mass wall with at least 1h of the
❑ Wood
❑ Wood
❑Does Not
'table for values.
402.2.5
[IN311
wall insulation on the wall
exterior, the exterior insulation
❑ Mass
❑ Mass
[--]Not Observable
0'
requirement applies.
❑Steel
❑Steel
❑Not Applicable.
303.2
Wall insulation Is installed per
❑Complies
Requirement will be met.
[IN411
manufacturer's instructions.
.❑Does
Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
11 High Impact (Tier 1) Wfl Medium Impact (Tier 2) B 1 Low Impact (Tier 3)
Project Title: Harrop Residence Report date: 04/11/17
Data filename: D:\Dropbox\06 Clients Will\2016\001 Finished Jobs\Harrop Residence\Harrop Page 6 of 8
Rescheck.rck
Section
#
Final Inspection Provisions
Plans Verified
Value
Field Verified
Value
Complies?
- --
Comments/Assumptions
& Req.ID
402.1.1,
Ceiling insulation R -value. Where
R-
R-_ ❑Complies
See the Envelope Assemblies
402.2.1,
> R-30 is required, R-30 can be
❑ Wood
❑ Wood ❑Does Not
table for values.
402.2.2
[Fill'
used if insulation is not
compressed at eaves. R-30 may
❑ Steel
❑ Steel .❑Not Observable
�
be used for 500 ft° or 20%❑Not
Applicable
(whichever is less) where
sufficient space is not available.
303.1.1.1,
Ceiling insulation Installed per
❑Complies
Requirement will be met.
303.2
manufacturer's instructions.
❑Does Not
(FI211
Blown Insulation marked every
300 ft'.
❑Not Observable
❑Not Applicable
402.2.3 (Attic
access hatch and door
R-
R-_ ❑Complies'.
Requirement will be met.
[F1311
Insulation aR-value of the
❑Does Not
�
adjacent assembly.
❑Not Observable
❑Not Applicable
402.4.2,
Building envelope tightness
ACH 50 =_
ACH 50 =_ ❑Complies
Requirement will be met.
402.4.2.1
verified by blower door test result)
❑Does Not
[FI1711
of <7 ACH at 50 Pa. This
-
❑Not Observable
requirement may instead be met
via visual inspection, In which
❑Not Applicable
case verification may need to
occur during Insulation
Inspection.
403.2.2
Post construction duct tightness_
cfm
_ cfm [Complies'
Requirement will be met.
[F1411
test result of s8 cfm to outdoors,
.
❑Does Not
or s12 cfm across systems. Or,❑Not
rough -in test result of s6 cfm
Observable',
across systems or s4 cfm
❑Not Applicable
without air handler. Rough -in test.
verification may need to occur
during Framing Inspection.
403.1.1
Programmable thermostats
-
❑Complies
Requirement will be met.
[FI932
installed on forced air furnaces
' 3❑Does
Not
❑Not Observable
❑Not Applicable
403.1.2
Heat pump thermostat installed
❑Complies
Requirement will be met.
[F[10]2
on heat pumps.
❑Does Not
'J
❑Not Observable
❑Not Applicable
403.4
Circulating service hot water„,...:
❑Complies
Requirement will be met.
(1`11112
systems have automatic or❑Does
Not
J
accessible manual controls.❑Not
Observable
❑Not Applicable
404.1
50% of lamps in permanent
❑Complies
Requirement will be met.
[FI611
fixtures are high efficacy lamps.
❑Does Not
9
❑Not Observable
❑Not Applicable
401.3
Compliance certificate posted❑Complies
.❑Does
Requirement will be met.
[F]7]
�.'.
Not
as
❑Not Observable
❑Not Applicable.
303.3
Manufacturer manuals for
:..
❑Complies
Requirement will be met.
[FI18]'
mechanical and water heating P,wsR.",
❑Does Not
equipment have been provided.
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
11 High Impact (Tier 1) 2'1 Medium Impact (Tier 2) T3 Low Impact (Tier 3)
Project Title: Harrop Residence Report date: 04/11/17
Data filename: D:\Dropbox\06 Clients Will\2016\001 Finished Jobs\Harrop Residence\Harrop Page 7 of 8
Rescheck.rck
1 J High Impact (Tier 1) 12 1 Medium impact( 2) 3 Low Impact (Tier 3)
Project Title: Harrop Residence Report date: 04/11/17
Data filename: D:\Dropbox\06 Clients Wi11\2016\001 Finished jobs\Harrop Residence\Harrop Page 8 of 8
Rescheck.rck
�(2009 IECC Energy
j Efficiency Certificate
Above -Grade Wall 21.00
Below -Grade Wall 5.00
Floor 38.00
Ceiling / Roof 50.00
Ductwork (unconditioned spaces):
Window 0.18
Door 0.18
Heating System:
Cooling System:_
Water Heater:
Name: Date:
Comments