HomeMy WebLinkAboutINSPECTION REPORT (08.20.14) - 13-00104 - 538 S 2nd W - The Mountain Lofts Women's Bld; 93 UnitsCommunity Development Department
Phone (208)359-3020
Inspection Hotline: (208)372-2344
INSPECTION
REPORT
Inspection Type Building Type Inspection
ELECTRICAL BLD-MFR ELEFINAL-R
Permit Number:
Address: 538 S 2nd W
Project:
13-00104 The Mountain Lofts - Bldg #1; 93
Units
Inspection Date
8/20/2014
Inspection Result: PASS
D ESCRIPTIO N CO MMEN TS STATUS
Bushings or equivalent protection for
cables entering boxes and other
enclosures. 300.4(F), 314.17, 314.42
COMPLETED
Disconnecting means on both permanently
connected and cord- and plug-connected
appliances. Article 422 Part III
COMPLETED
Circuits for mechanical equipment have
correct conductor size and overcurrent
protection. Articles 422, 424, 430, and 440
COMPLETED
Proper receptacle ratings based on
branch-circuit ratings, including
receptacles for electric dryers. 210.21,
210.24, 250.140
COMPLETED
Outdoor receptacles are GFCI protected
unless they are not readily accessible and
are supplied by circuits for deicing or
snow-melting equipment(GFPE required
otherwise with a disconnecting
means-breaker lock). 210.8(A)(3), 426.28,
426.50(A)
COMPLETED
Proper identification of all overcurrent
devices and disconnects. 110.22,
230.70(B), 408.4
COMPLETED
Open spaces in panelboard fronts. 110.12 COMPLETED
Approved for a final and C.O.Approved for a final and TEMPORARY
C.O. only-need to finish labeling units,
meters and fire alarm devices. Also need
to finish up loose ends throughout-Jack
has list of these items. This does not give
consent that people can move into the
units to live. This will be done later this
week or first part of next.
COMPLETED
Page 1 of 2
Inspector: Bret Stoddard
Page 2 of 2