Loading...
HomeMy WebLinkAboutINSPECTION REPORT (08.12.14) - 13-00104 - 538 S 2nd W - The Mountain Lofts Women's Bld; 93 UnitsCommunity Development Department Phone (208)359-3020 Inspection Hotline: (208)372-2344 INSPECTION REPORT Inspection Type Building Type Inspection ELECTRICAL BLD-MFR ELEFINAL-R Permit Number: Address: 538 S 2nd W Project: 13-00104 The Mountain Lofts - Bldg #1; 93 Units Inspection Date 8/12/2014 Inspection Result: PASS D ESCRIPTIO N CO MMEN TS STATUS Gaps around boxes in walls. 314.21 COMPLETED Polarity of devices and luminaires. 200.10(B), 200.11, 410.23, 406.9 COMPLETED Proper use of connectors and fittings and for protection of cables. 300.15 COMPLETED Bushings or equivalent protection for cables entering boxes and other enclosures. 300.4(F), 314.17, 314.42 COMPLETED Disconnecting means on both permanently connected and cord- and plug-connected appliances. Article 422 Part III COMPLETED Properly sized circuits are provided for specific kitchen appliances, such as dishwashers, disposals, ranges, cooktops, trash compactors, and the like. 210.23, 422.10 COMPLETED Proper identification of all overcurrent devices and disconnects. 110.22, 230.70(B), 408.4 COMPLETED Open spaces in panelboard fronts. 110.12 COMPLETED Approved for a final and C.O. in the noted levels. Inspected levels 3, 4 and 5 corridors and commons areas. Need to cover NM-B cabling above panels where exposed, need to cover NM-B on level 3 west corridor server room up high, will re-inspect on other level corridors. COMPLETED Inspector: Bret Stoddard