HomeMy WebLinkAboutINSPECTION REPORT (08.12.14) - 13-00104 - 538 S 2nd W - The Mountain Lofts Women's Bld; 93 UnitsCommunity Development Department
Phone (208)359-3020
Inspection Hotline: (208)372-2344
INSPECTION
REPORT
Inspection Type Building Type Inspection
ELECTRICAL BLD-MFR ELEFINAL-R
Permit Number:
Address: 538 S 2nd W
Project:
13-00104 The Mountain Lofts - Bldg #1; 93
Units
Inspection Date
8/12/2014
Inspection Result: PASS
D ESCRIPTIO N CO MMEN TS STATUS
Gaps around boxes in walls. 314.21 COMPLETED
Polarity of devices and luminaires.
200.10(B), 200.11, 410.23, 406.9
COMPLETED
Proper use of connectors and fittings and
for protection of cables. 300.15
COMPLETED
Bushings or equivalent protection for
cables entering boxes and other
enclosures. 300.4(F), 314.17, 314.42
COMPLETED
Disconnecting means on both permanently
connected and cord- and plug-connected
appliances. Article 422 Part III
COMPLETED
Properly sized circuits are provided for
specific kitchen appliances, such as
dishwashers, disposals, ranges, cooktops,
trash compactors, and the like. 210.23,
422.10
COMPLETED
Proper identification of all overcurrent
devices and disconnects. 110.22,
230.70(B), 408.4
COMPLETED
Open spaces in panelboard fronts. 110.12 COMPLETED
Approved for a final and C.O. in the noted
levels.
Inspected levels 3, 4 and 5 corridors and
commons areas. Need to cover NM-B
cabling above panels where exposed,
need to cover NM-B on level 3 west
corridor server room up high, will
re-inspect on other level corridors.
COMPLETED
Inspector: Bret Stoddard