HomeMy WebLinkAboutINSPECTION REPORT (07.22.14) - 13-00105 - 538 S 2nd W - The Mountain Lofts Men's Bld; 68 UnitsCommunity Development Department Phone (208)359-3020 Inspection Hotline: (208)372-2344 INSPECTION REPORT Inspection Type Building Type Inspection ELECTRICAL BLD-MFR ELEFINAL-R Permit Number: Address: 538 S. 2nd W. Project: 13-00105 The Mountain Lofts II - 68 Units Inspection Date 7/22/2014 Inspection Result: PASS D ESCRIPTIO N CO MMEN TS STATUS Positioning of boxes intended to be flush with combustible and noncombustible finished surfaces. 314.20 COMPLETED Gaps around boxes in walls. 314.21 COMPLETED Polarity of devices and luminaires. 200.10(B), 200.11, 410.23, 406.9 COMPLETED Unused openings in boxes and other enclosures are closed. 110.12, 314.17(A), 312.5(A) COMPLETED Spacing of receptacles for walls and countertops, including islands and peninsulas. 210.52(A) and (C) COMPLETED Countertop receptacles are provided with GFCI protection. 210.8(A)(6) COMPLETED Bathroom receptacles are GFCI protected. 210.8(A)(1) COMPLETED Arc-fault circuit-interrupter (AFCI) protection on bedroom circuits. 210.12 COMPLETED Proper receptacle ratings based on branch-circuit ratings, including receptacles for electric dryers. 210.21, 210.24, 250.140 COMPLETED Open spaces in panelboard fronts. 110.12 COMPLETED Approved for a final and C.O. in the noted levels. Final for electrical only units #2104, 2105, 2106, 2107, 2108, 2109, 2119 and 2120. COMPLETED Inspector: Bret Stoddard