INSPECTION
REPORT
Inspection Type Building Type Inspection
ELECTRICAL BLD-MFR ELEFINAL-R
Permit Number:
Address: 538 S. 2nd W.
Project:
13-00105 The Mountain Lofts II - 68 Units
Inspection Date
7/22/2014
Inspection Result: PASS
D ESCRIPTIO N CO MMEN TS STATUS
Positioning of boxes intended to be flush
with combustible and noncombustible
finished surfaces. 314.20
COMPLETED
Gaps around boxes in walls. 314.21 COMPLETED
Polarity of devices and luminaires.
200.10(B), 200.11, 410.23, 406.9
COMPLETED
Unused openings in boxes and other
enclosures are closed. 110.12, 314.17(A),
312.5(A)
COMPLETED
Spacing of receptacles for walls and
countertops, including islands and
peninsulas. 210.52(A) and (C)
COMPLETED
Countertop receptacles are provided with
GFCI protection. 210.8(A)(6)
COMPLETED
Bathroom receptacles are GFCI protected.
210.8(A)(1)
COMPLETED
Arc-fault circuit-interrupter (AFCI)
protection on bedroom circuits. 210.12
COMPLETED
Proper receptacle ratings based on
branch-circuit ratings, including
receptacles for electric dryers. 210.21,
210.24, 250.140
COMPLETED
Open spaces in panelboard fronts. 110.12 COMPLETED
Approved for a final and C.O. in the noted
levels.
Final for electrical only units #2104, 2105,
2106, 2107, 2108, 2109, 2119 and 2120.
COMPLETED
Inspector: Bret Stoddard