HomeMy WebLinkAboutINSPECTION REPORT 1 (08.20.14) - 13-00105 - 538 S 2nd W - The Mountain Lofts Men's Bld; 68 UnitsCommunity Development Department Phone (208)359-3020 Inspection Hotline: (208)372-2344 INSPECTION REPORT Inspection Type Building Type Inspection FIRE BLD-MFR FA-FINAL Permit Number: Address: 538 S. 2nd W. Project: 13-00105 The Mountain Lofts II - 68 Units Inspection Date 8/20/2014 Inspection Result: PASS D ESCRIPTIO N CO MMEN TS STATUS Verify listing of power-limited source and that the power circuit is not protected by GFCI or AFCI devices.760.41(B) COMPLETED Signaling devices placed to meet minimum code compliance db or visual notification. IFC, NFPA 72 COMPLETED Witnessed 24 Hour/5 minute test with system fully functional-verify with monitoring station times if not logged in panel event logger(LCD screen). COMPLETED Verify two lines of communication with monitoring station. COMPLETED All valves on sprinkler system that could hinder the performance of sprinkler system tied into fire alarm system-monitored (tamper switches) and labeled as supervisory in panel. COMPLETED Address of site accurate on report-monitoring station. COMPLETED Witnessed operation of signaling devices.COMPLETED Witnessed operation of manual pull station(s). COMPLETED Witnessed flow switch operation with water gong (outside) and fire alarm panel initiation-must operate within 30 to 90 second operation. *Make sure flow orifice is sized to the smallest sprinkler head in the system such as inspectors test or actual head installed in discharge orifice. COMPLETED Witnessed operation of supervisory devices such as tamper switches, etc. COMPLETED Remote annunciator functional and located as per approved location-plans. COMPLETED Page 1 of 2 Fire Alarm panel labeled with electrical panel and circuit number. COMPLETED Electrical panel circuit painted red.COMPLETED Fire alarm system control functions operational-door holders. COMPLETED Resistors not installed on circuits in panel.COMPLETED Witnessed monitoring functional with monitoring station. COMPLETED Batteries marked with date installed.COMPLETED Copy of report from NICET fire alarm contractor upon completion and put in file at office-scanned.(For each individual system-multiple buildings or systems) Fire alarm contractor report not submitted to us yet. COMPLETED FACP label on door of room fire alarm panel is located. Label not installed on doors of building one or two. COMPLETED As built plan in FACP for fire department.As built plans not done yet for building 1 or 2. COMPLETED Approved for a final and C.O.Approved for a final and TEMPORARY C.O. only-need to finish labeling units, meters and fire alarm devices. Also need to finish up loose ends throughout-Jack has list of these items. This does not give consent that people can move into the units to live. This will be done later this week or first part of next. COMPLETED Inspector: Bret Stoddard Page 2 of 2