Daily Field Diary
Observations, Items, and Locations
Deficiencies:
Inspector Signature:Certification #:
Page 1 of 2
NoYes
°F
Description: Description: Description:
Allied Testing & Inspection
208.970.6237 Rexburg, ID
Gorilla Performance
160013
JRW
JRW 12/7/16
Clear
10:00 AM
5
12:00 PM
I arrived on site and began my observations of the 4 concrete piers on the West of the building. I observed
that there was 8-12" of the concrete exposed which I was able to perform testing on. I began by using the
rebar detector to locate the reinforcement. I observed that there was vertical and horizontal reinforcement
in general conformance with the project plans. The rebar detector does not verify size or grade of
reinforcement.
I also performed strength testing with a Schmidt rebound hammer on 2 of the piers. I observed that the
average strength of the 2 columns was 4,864 psi.
Digitally signed by Jacob Christensen
DN: cn=Jacob Christensen, o=Allied
Testing and Inspection, LLC, ou,
email=alliedtandi@gmail.com, c=US
Date: 2016.12.09 15:54:10 -07'00'
8129697
Page 2 of 2
Description: Description:
Description: Description:
Additional Comments: