Loading...
HomeMy WebLinkAboutDRY SPRINKLER PRODUCT INFO - 16-00627 - 00631 - Sawtelle ApartmentsReliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model DH56 HSW Model DH56 HSW Recessed Model DH56 HSW Concealed Quick Response, Extended Coverage Dry Sprinklers B u l l e t i n 0 1 6 R e v . H Bulletin 016 Rev. H For coverages up to 28 feet wide and 10 feet long(1). 250 psi (17,2 bar) rated. Features: 1. Coverage for long and narrow spaces such as hallways, corridors, decks and rooms up to 28 feet wide and 10 feet long.(1) 2. Deflector to ceiling dimensions are: 4” (102mm) min. to 12” (305mm) max. 3. Minimum spacing between sprinklers 16 feet (4.9m).(1) 4. Polyester Coated or Electroless Nickel PTFE (Teflon®)* Plated Corrosion Resistant Sprinklers. *Concealed Sprinkler is not corrosion resistance. 5. UL Listed for extended coverage, light hazard applications. 6. 5.6 K Factor. 7. Sprinkler is approved for 250 psi (17,2 bar) applications. 8. Quick response performance. 9. ½” (13mm) adjustment of escutcheon and cover. 10. Concealed cover plate can prevent the sprinkler from being used for unintended purposes. No exposed thermal element with the concealed version. 11. Push-on/thread-off sturdy convenient escutcheon for recessed and cover for concealed. 12. Factory assembled sprinkler & cup, shipped complete with bulb protector for concealed and FP recessed versions. 13. Sprinkler & cup assembly and escutcheon or cover are separately packaged. 14. Available in a variety of plated and painted finishes (1) See Fig. 9. Approval Organizations 1. Listed by Underwriters Laboratories Inc. and UL certified for Canada (cULus) 2. NYC MEA 258-93-E Patents US Patent No. 7,841,418 Other Patents Pending Products Description The Model DH56 are quick response extended cover- age sidewall dry sprinklers for use in light hazard applica- tions. The Model DH56 dry sprinkler with SWC cover plate is a concealed sprinkler that uses Reliable’s push on/thread off sidewall cover. This sprinkler has the cup factory mounted and is shipped with a bulb protector that protects the 3mm frangible glass bulb during shipping and post installation fin- ishing operations. The DH56 can be combined in the field with the FP Escutcheon to make a recessed dry sprinkler. DH56 HSW Concealed with SWC coverplate (See Fig. 7) DH56 HSW (See Fig. 4) DH56 HSW FP Recessed (See Fig. 6) DH56 HSW/HB (See Fig. 5) The SWC cover plate and FP recessed escutcheons have ½” adjustment. The SWC cover plate is attached with 135 & 165 degree solder. In the event of a fire the rising ambient temperature melts the solder and the cover plate is ejected away by springs exposing the 3mm frangible glass bulb. The use of a 3mm bulb allows quick response which enables the sprinkler to apply water to a fire sooner than standard response sprinklers of the same temperature rating. Model DH56 dry sprinklers are intended for use in dry and preaction systems to protect areas subjected to freez- ing temperatures and unheated portions inside and outside buildings. See Fig. 1 for guidelines on using dry sprinklers in wet systems.*DuPont Registered Trademark 2. Environments wherein dry sprinklers are employed can be corrosive. For this reason, Model DH56 dry sprinklers have a special wax fillet placed in the gap between the cup that supports the bulb and the wrenching boss. This wax will not interfere with the operation of the sprinkler, and it prevents contaminants from entering the internal portion of the drop nipple. The wax must not be removed. Application The Model DH56 is a horizontal sidewall dry sprinkler intended for installation in light hazard occupancies in ac- cordance with NFPA 13. These sprinklers are designed to provide fire protection in long and narrow spaces such as hallways, corridors, decks and rooms up to 28 feet (8,5m) wide and 10 feet (3m) long. They are rated for 250 psi (17,2 bar) and can be mounted between 4 and 12 inches (102 and 305mm) down from the ceiling. General Installation Instructions Model DH56 dry sprinklers must be installed only in stan- dard (ANSI B 16.3 class 150 and ANSI B 16.4 class 125) pipe tees in the horizontal position, even at branch line ends. They should not be installed into elbows or pipe couplings located on drop nipples to the sprinklers. For these and other fittings including CPVC, the dry sprinkler should be installed into a fitting to allow protrusion into the fitting in ac- cordance with the diagrams. The “A” dimension of the dry sprinkler, which extends into a freezing zone from wet pipe systems, should be selected to provide, as a minimum, the specified lengths in inches shown in Fig. 1. Caution: Do not install Model DH56 HSW Dry sprinklers into CPVC adapter fittings or tees that have an internal obstruction. This will damage the sprinkler and /or the fitting. Refer to Fig. 8 DH56 HSW To install the DH56 HSW dry sprinkler cut a 21/8” diameter hole in the wall as shown in Fig. 4. Use the Model F3 instal- lation wrench (see Fig. 3) on the square boss to tighten the sprinkler until it is secured in the sprinkler fitting1. Apply a Teflon* based sealant to the sprinkler threads before install- ing in the sprinkler. Installation is completed by removing the orange glass bulb-protector and assembling the slip-on escutcheon to the sprinkler’s can. DH56 HSW/HB To install the DH56 HSW/HB dry sprinkler cut a 2½” di- ameter hole in the wall as shown in Fig. 5. Use the Model F3 installation wrench (see Fig. 3) on the square boss to tighten the sprinkler until it is secured in the sprinkler fitting1. Apply a Teflon* based sealant to the sprinkler threads be- fore installing in the sprinkler. Installation is completed by removing the orange glass bulb-protector and assembling the slip-on escutcheon to the sprinkler’s can. DH56 HSW Recessed with FP Escutcheon To install the DH56 HSW dry sprinkler with the FP Escutch- eon as a recessed sprinkler cut a 25/8” diameter hole in the wall as shown in Fig. 6. Temporarily remove the plastic pro- tective cap, and then use the Model XLO2 wrench1 (see Fig. 2) to tighten the sprinkler until it is secured in the sprin- kler fitting. Note: The Model XLO2 wrench has a notch in it to accommodate the deflector top. This wrench can only be inserted one way. Care must be taken not to damage the deflector during tightening. Apply a Teflon* based seal- ant to the sprinkler threads before installing in the sprinkler. It is recommended that the sprinkler be protected during plastering and painting operations by reinstalling the plastic protective cap. Installation is completed by removing the protective cap and inserting the push-on escutcheon. Turn clockwise to adjust the escutcheon against the wall. DH56 HSW Concealed with SWC Cover Plate To install the DH56 HSW dry sprinkler with the SWC cover- plate as a concealed sprinkler, cut a 21/8” diameter hole into the wall as shown in Fig. 7. Temporarily remove the plastic protective cap, and then use the Model XLO2 wrench1 (see Fig. 2) to tighten the sprinkler until it is secured in the sprin- kler fitting. Note: The Model XLO2 wrench has a notch in it to accommodate the deflector top. This wrench can only be inserted one way. Care must be taken not to damage the deflector during tightening. Apply a Teflon* based seal- ant to the sprinkler threads before installing in the sprinkler. It is recommended that the sprinkler be protected during plastering and painting operations by reinstalling the plastic protective cap. Installation is completed by removing the protective cap and inserting the coverplate. Coverplate as- semblies provide ½” (13mm) of adjustment. Final adjust- ment is made by turning the coverplate clockwise until the skirt flange makes full contact with the wall surface. Cover removal requires turning in the counter-clockwise direction. Concealed coverplate assemblies are listed only for use with specific sprinklers. The use of any other concealed wall sprinkler or the use of the SWC coverplate on any sprinkler with which it is not specifically listed will void all guarantees, warranties, listings and approvals. Note: DH56 and DH56 Recessed Sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling, and installation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SER- VICE FOR FIRE PROTECTION. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDO- ING THE CLASP BY HAND. DO NOT USE TOOLS TO RE- MOVE THE PROTECTORS. *DuPont Registered Trademark 1 Installation Wrenches: Throughout this technical bulletin, Reliable has specified specific installation wrenches for use on each version of our sprinklers. A pipe wrench may also be used to install a dry sprinkler provided that it only interfaces with the steel outer tube of the assembly (Item #8 on fig 10). Keep in mind that a pipe wrench will incorporate a large amount of torque into the final assembly. This torque will have to be matched or exceeded upon the sprinkler’s removal at a later date. Fig. 1 3. 4. Step 3 Step 2 Step 1 Fig. 2 - XLO2 Wrench Fig. 3 - F3 Wrench Maintenance Model DH56 Quick Response Dry Sprinklers should be in- spected and the sprinkler system maintained in accordance with NFPA 25. Do not remove the factory applied thermally sensitive wax fillet between the bulb supporting cup and the wrenching boss. Do not replace this wax with a substitute substance. An alternate substance may interfere with proper operation of the sprinkler. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in their original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Model DH56 Quick Response Extended Coverage Horizontal Sidewall Dry Sprinkler Specifi cation Sprinklers shall be a [quick response – cULus Listed] ex- tended coverage horizontal sidewall sprinkler for light hazard occupancies. Sprinklers to be of bronze frame construction with a special deflector capable of providing a discharge over a coverage area of 28 ft. (8,5m) wide, and 10 ft. (3m) long horizontal throw. Water seal assembly shall consist of a Teflon* coated Belleville spring washer. Installation shall permit sprin- kler deflectors to be positioned 4“ (102mm) to 12” (305mm) below the ceiling. Sprinklers shall have a nominal K-factor of 5.6 (80), and 1” NPT thread. Sprinkler temperature rating shall be [155°F (68° C)] and [200°F (93°C)]. Rated working pressure shall be 250 psi (17.2 bar). Standard finish: [white] [chrome][bronze][Special finish– specify]. Quick response extended coverage horizontal sidewall dry sprinklers shall be Reliable Model DH56, SIN RA1664 (Bulletin 016). For recessed EC horizontal sidewall sprinklers: Replace “horizontal sidewall” with “recessed horizontal sidewall.” Add: (1) Recessed escutcheon assembly shall be a two-piece es- cutcheon of push-on and thread off design with ½” (13mm) adjustment. Standard finish shall be chrome, white and brass. Quick response recessed horizontal sidewall sprinklers shall be Reliable Model DH56, SIN RA1664 (Bulletin 016). For concealed EC horizontal sidewall sprinklers: Replace “horizontal sidewall” with “concealed horizontal sidewall.” Add: Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½” (13mm) cover plate adjust- ment. Cover plate temperature rating shall be 135°F (57°C) for 155°F (68°C) dry sprinkler and 165°F (74°C) for 200°F (93°C) dry sprinkler. A bulb protector shall be provided and factory installed inside the sprinkler cup to protect the glass bulb from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [white] [Custom Color– specify]. Quick response extended coverage concealed horizontal sidewall dry sprinklers shall be Reliable Model DH56, SIN RA1664 (Bulletin 016). Technical Data: K Factor Thread Size Temperature Rating Maximum Ambient Temperature Sprinkler Identifi cation Number (SIN)US Metric Sprinkler SWC Cover 5.6 80 1” 155°F (68°C) 135°F (57°C) 100°F (38°C) RA1664 175°F (79°C) 165°F (74°C) 150°F (66°C) 200°F (93°C) 165°F (74°C) 150°F (66°C) Coverage Area Maximum Coverage Area Width x Length ft x ft (m x m) Flow Rate gpm (L/min) Pressure psi (bar) 28 x 8 (8,5 x 2,4) 23 (87,1) 16.9 (1,2) 28 x 10 (8,5 x 3) 28 (106) 25 (1,7) Approval Type: • Quick Response, Extended Coverage. • Approved for installation in accordance with NFPA 13 for light hazard occupancies. *DuPont Registered Trademark 5. Note: The Sprinkler Can protrudes ¼” when escutcheon is in nominal position. Escutcheon adjustment provides - ¼” (-6mm) to +1¼” (+32mm) “A” dimension adjustment range. Fig. 4 Note: The Sprinkler Can protrudes 1¼” when escutcheon is in nominal position. Escutcheon adjustment pro- vides - ½” (-12.7mm) to +½” (+12.7mm) “A” dimension adjustment range. Fig. 5 6. Fig. 7 Note: Do not install the Model DH56 Dry EC Horizontal Recessed Sidewall Sprinkler in walls which have positive pressure in their side space. Fig. 6 7. Fig. 8 Ordering Information Specify: 1. Sprinkler Type (select one): (a) Model DH56 Dry EC HSW (b) Model DH56 Dry EC HSW/HB (c) Model DH56 Dry Recessed EC HSW/FP (d) Model DH56 Dry Concealed EC HSW 2. Sprinkler Temperature Rating. 3. Sprinkler Finish. 4. Cover Plate/Escutcheon Finish. 5. Length: “A” Dimension (face of tee to face of ceiling or wall) in 1/4” (6mm) increments. Notes: 1. The “A” dimension is based on a nominally gauged pipe thread “make-up” of 0.600” (15mm) per ANSI B2.1 [7½ threads approximately]. 2. All platings and paintings are decorative and intended for interior use. UL Listing Category Sprinklers, Automatic and Open. Quick Response Sprinklers. Installation Wrench1 Model XLO2 Sprinkler Wrench (Recessed & Concealed) Model F3 Sprinkler Wrench Note: A leak tight 1” NPT sprinkler joint can be obtained with a torque of 20-30 ft-lbs (27.1 - 40.7 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprinklers. Escutcheon Data: FP cup/escutcheon assembly - ½” (13mm) adjustment Finishes (1) Standard Finishes (1) Sprinkler Escutcheon Cover Plate White or Black Polyester (2) ChromeBronze Brass (3) WhiteChrome White Special Application Finishes Sprinkler HSW/HSW HB Escutcheons Electroless Nickel PTFE(Teflon®)*(2)Electroless Nickel PTFE (Teflon®)* (1) Other colors and finishes are available. Consult factory for details. (2) cULus listed Corrosion Resistant (3) Not available for HB escutcheons. Note: Paint or any other coatings applied over the factory finish will void all approvals and warranties. Fig. 9 1 Installation Wrenches: Throughout this technical bulletin, Reliable has specified specific installation wrenches for use on each version of our sprinklers. A pipe wrench may also be used to install a dry sprinkler provided that it only interferes with the steel outer tube of the assembly (item #8 on fig 16). Keep in mind that a pipe wrench will incorporate a large amount of torque into the final assembly. This torque will have to be matched or exceeded upon the sprinkler removal at a later date. 8. *DuPont Registered Trademark 9. Fig. 10 ITEM # DESCRIPTION MATERIAL SPECIFICATION 1 FRAME BRASS PER UNS C83600 2 DEFLECTOR BRONZE PER UNS C51000 3 LOAD SCREW BRASS PER UNS C22000 4 SEAT ADAPTOR BRASS ALLOY PER UNS C36000 5 BULB INSERT COPPER ALLOY PER UNS C331400 6 GLASS BULB GLASS W/GLYCERIN SOLUTION 7 ORIFICE ADAPTOR BRASS ALLOY PER UNS C36000 8 OUTER TUBE GALVANIZED STEEL 9 INNER TUBE BRASS ALLOY PER UNS C23000 10 YOKE BRASS ALLOY PER UNS C38000 11 INLET BRASS ALLOY PER UNS C35330 12 CAP BRASS ALLOY PER UNS C54400 13 SPRING WASHER/SEAL TEFLON COATED BERYLLIUM NICKEL 14 FLIP DISK BRASS ALLOY PER UNS C54400 15 CAN/ESCUTCHEON PAINTED OR PLATED MILD STEEL MATERIAL SPECIFICATIONS Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 02/15 P/N 9999970308 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Reliable...For Complete Protection