FLAMEGUARD PRODUCT INFO - 16-00627 - 00631 - Sawtelle Apartments
FG-2-0215 Corrosion Resistant CPVC Material Does Not Sustain Biological Growth Unlike metal systems, FlameGuard® CPVC products never rust, scale or pit and do not sustain biological growth - a cause of Microbiologically Infl uenced Corrosion (MIC) which can destroy metal fi re sprinkler systems from the inside out. Superior Flow Characteristics for Lower Friction Losses The smooth-wall interior surfaces of FlameGuard® CPVC systems result in reduced friction loss over metal systems. The design fl ow characteristics remain constant throughout the life of the product because there is no interior corrosion in the system due to microbiological activity. Pressure Rated to 175 psi (1200kpa) @ 150°F (65°C) FlameGuard® CPVC Products are produced in combinations of Schedule 40 and Schedule 80 Fitting confi gurations con-forming to ASTM F 438 or F 439 standards and FlameGuard® SDR 13.5 CPVC Fire Sprinkler Pipe conforming to ASTM F 442 standards. UL® and FM® Rated working pressure is 175 psi (1200kpa) @ 150°F (65°C) (LPCB rated to 120°F) (49°C). Spears® FlameGuard® CPVC Fire Sprinkler Products provide a cost effective alternative to metal systems with advantages of high corrosion resistance, improved system hydraulics, ease of installation and quick assembly with common tools. CPVC Fire Sprinkler Systems are based on proven products that have been in continuous service for over 40 years. Spears® FlameGuard® products are approved by UL®, FM® Global, LPCB and Certifi ed by NSF International for potable water use. Check local codes for restrictions and limitations. Easy Installation for Lower Costs FlameGuard® CPVC system installations significantly reduce costs over conventional metal piping by virtually eliminating prefabrication. Systems can be fully installed on site using solvent cement joining methods. UL® Listed for U.S. and Canada in NFPA 13, 13R & 13D Systems FlameGuard® CPVC Fire Sprinkler Products are UL® listed for U.S. and Canada applications for Light Hazard occupancies as defi ned in NFPA 13, Residential occupancies up to and including 4-stories as defined in NFPA 13R, and Residential occupancies for one and two family dwellings and manufactured homes as defi ned in NFPA 13D. Consult Spears® FlameGuard® CPVC Fire Sprinkler Products Installation Instructions and NFPA Standards for additional applications including air plenum, system risers, concealed, exposed, underground, combustable attic, garage, basement and low pressure dry piping installations. Full Limited Lifetime Warranty FlameGuard® CPVC Fire Sprinkler Products carry a limited lifetime warranty against defects in material or workmanship. Consult Spears® warranty for additional details. FlameGuard® CPVC FIRE SPRINKLER PRODUCTS Corrosion Resistant • Superior Flow • Ease of Installation MANAGEMENT SYSTEMS Complete System of Pipe, Fittings & Solvent Cement PROGRESSIVE PRODUCTS FROM SPEARS® INNOVATION & TECHNOLOGY Visit our website at www.spearsmfg.com Assessed to ISO 9001: 2008 Certificate number 293 © Copyright 2016 Spears® Manufacturing Company. All Rights Reserved. Printed in the United States of America 06/16. FG-2-0215 Pioneer in Molded-in Metal Insert Head Adapters Patent No. 5,437,481 Spears® pioneered the development of the FlameGuard® molded-in- place metal thread insert for connection of sprinkler heads to CPVC fi re sprinkler systems, plus Metal FIPT threaded female adapters for metal- to-plastic transitions. Developed the Special Reinforced (SR) Head Adapters Patent No. 5,582,439 Spears® FlameGuard® continuous improvement program developed the technology to produce a superior patented plastic threaded fi tting - the Special Reinforced (SR) Design. This unique design incorporates a patented thermoplastic compression process that equalizes stresses generated by tapered thread joint make-up. All CPVC plastic body and threads provide a more uniform construction and improved corrosion resistance. Full Assortment of Specialty Products & Fitting Confi gurations Spears® FlameGuard® products provide the specialty fi ttings needed in today’s fi re sprinkler systems. The GripLoc™ Elbow, Tee, Cap and Coupling and GripLoc™ Repair Coupling for quick no-cement repairs; the Adjustable Drop Nipple for fi ne-tuning to fi nished ceiling height; and Ringed Head Adapter for ease of locating during installation. Plus a full assortment of fi ttings including Grooved Coupling Adapters, Unions and Flanges sizes 3/4" through 3". Spears® Solvent Cements & Thread Sealant FlameGuard® products should be installed using Spears® FS-5 One-Step Solvent Cement. For threaded joints, use Spears® BLUE 75™ Thread Sealant that has been tested for compatibility with FlameGuard® CPVC Fire Sprinkler Products. Spears® TorqueSafe™, SofTorque™ and QuickTorque™ Gasket Sealed Adapter requires no sealant. Consult sprinkler head manufacturer prior to use. Spears® FlameGuard® . . . The Leader in Innovative CPVC Fire Sprinkler System Products Revolutionary Gasket Sealed Head Adapter Choices Patent No. 8,474,472 - 8,297,663 - 7,458,613 • Requires NO Thread Sealants • Eliminates Stress • Prevents Over Tightening • Provides Easy Frame Alignment Spears® revolutionary Gasket Sealed Head Adapters feature an elastomer gasket seal at the base of the threads. The gasket seal allows a modifi ed thread design that eliminates radial stress and associated problems typical with tapered thread joint make up. Choose from TorqueSafe™ design with rotating brass thread insert, SofTorque™ design with Special Reinforced (SR) plastic threads and compressible gasket or QuickTorque™ with similar features plus brass threads. Complete Size Range of CPVC Pipe Spears® FlameGuard® CPVC Fire Sprinkler Pipe is available in sizes 3/4" to 3"; and conforms to ASTM F 442 standard for SDR 13.5 CPVC pipe. Lead Free TorqueSafe™, SofTorque™ & QuickTorque™ Fittings Lead Free GripLoc™ Elbow, Tee, Cap, Coupling & Repair Couplings Lead Free