Loading...
HomeMy WebLinkAboutCOMCHECK 2 - 16-00628, 629 - Sawtelle Apts - 18 Plex #1COMlcheck Software Version 4.0.3.0 Envelope Compliance Certificate Project Information Energy Code: Project Title: Location: Climate Zone: Project Type: Vertical Glazing / Wall Area: Construction Site: Rexburg, ID 83440 Building Area 2012 IECC Sawtell Apartments 18 plex Rexburg, Idaho 6b New Construction 9% Owner/Agent: Floor Area 1 -Dormitory: Residential 3042 Designer/Contractor: Design Intelligence LLC Rexburg, ID 83440 Additional Efficiency Package High efficiency HVAC. Systems that do not meet the performance requirement will be identified in the mechanical requirements checklist report. Envelope Assemblies Assembly Gross Area Cavity Cont. Proposed Budget U. or R -Value R -Value U -Factor Factory,) Perimeter Roof 1: Attic Roof with Wood Joists, [Bldg. Use 1 - Dormitory] 3042 49.0 0.0 0.021 0.021 Exterior Wall 1: Wood -Framed, 16" o.c., [Bldg. Use 1 - Dormitory] 8534 21.0 0.0 0.062 0.051 Window 1: Vinyl/Fiberglass Frame:Operable, Pert. Specs.: Product ID 756 --- --- 0.290 0.430 Window, SHGC 0.70, [Bldg. Use 1 - Dormitory] (b) Door 1: Insulated Metal, Swinging, [Bldg. Use 1 - Dormitory] 380 --- --- 0.290 0.370 Floor 1: Slab-On-Grade:Unheated, Vertical 2 ft., [Bldg. Use 1 - 336 --- 10.0 0.540 0.520 Dormitory] (c) (a) Budget U -factors are used for software baseline calculations ONLY, and are not code requirements. (b) Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. (c) Slab -On -Grade proposed and budget U -factors shown in table are F -factors. Envelope Compliance Statement Signature Project Title: Sawtell Apartments 18 plex Report date: 10/13/16 Data filename: S:\Scott\Year 2016\2016-120 Sawtell Apts\18 Plex\090116 146 N 1st W 18 Plex Apt Comcheck.i Page 1 of 8 COMcheck Software Version 4.0.3,0 Inspection Checklist Energy Code: 2012 IECC Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. C103.2 ;Plans and/or specifications provide all LIComplies [PR1]1 information with which compliance ❑Does Not -:❑Does Not ;can be determined for the building ❑Not Observable' ;store, and distribution/sorting area❑Not I have a measured haze value > 90❑Nat ,envelope and document where exceptions to the standard are ❑Not Applicable :claimed. 0406 ;Plans, specifications, and/or ❑Complies [PR9]1 !calculations provide all information ',.❑Does Not !with which compliance can be :determined for the additional energy '..❑Not Observable: lefficiency package options. []Not Applicable C402.3.1 ;The vertical fenestration area <= 30 '..❑Complies [PR10]1 :percent of the gross above -grade wall❑Does Not area.❑Not Observable C402.3.1 ;The skylight area <= 3 percent of the❑Complies [PR11]1 ;gross roof area.❑Does Not ❑Not Observable. EINot bservablei ❑Nat Applicable C402.3.2. ;Skylights in office, storage, L -Complies 2 :automotive service, manufacturing, -:❑Does Not [PR15]1 ;non -refrigerated warehouse, retail Observable ;store, and distribution/sorting area❑Not I have a measured haze value > 90❑Nat Applicable percent unless designed to exclude ,direct sunlight. Additional Comments/Assumptions: - _ - Impact 1 High Impact (Tier f) 2 ,Medi um Impact (Tier 2) 1 3 Low Imp(Tier 3) ---- ---- ._-_...- _. a Project Title: Sawtell Apartments 18 plex Report date: 10/13/16 Data filename: S:\Scott\Year 2016\2016-120 Sawtell Apts\18 Plex\090116 146.N 1st W 18 Plex Apt Comcheck., Page 2 of 8 Additional Comments/Assumptions: ------------------ _. 1 -High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Sawtell Apartments 18 plex Report date: 10/13/16 Data filename: S:\Scott\Year 2016\2016-120 Sawtell Apts\18 Plex\090116 146 N 1st W 18 Plex Apt Comcheck.- Page 3 of 8 =Foo#ing (Fotf@tlatlotl anspec#ion Conpllos' Coax+mon#sJAssump#ions # 2 6 ;Slab edge insulation R -value. ; ❑Complies See the envelope Assemblies table for values. [FOAIM 9.0''_ ❑Does Not tt.....3❑Not Observable -,_._.._ ❑Not Applicable .. --'._..___---____- 3032 Slab edge insulation installed per❑Complies M.041manufacturer's instructions. ❑Does Not ❑Not Observable; s ❑Not Applicable X402 2 6 (Slab edge insulation depth/length.❑Complies :See the Envelope Assemblies table for values [F5],,, :=,Slab insulation extending away from❑Does Not `. k building is covered by pavement or - Observable { ' >= 10 inches of soil.❑Not ❑Not Applicable C403.2.8. ;Exterior insulation protected against❑Complies u 1 damage, sunlight, moisture, wind,❑Does Not [FO6]1 ;landscaping and equipment Observable ;maintenance activities.❑Not ❑Not Applicable C402.2.8-; Bottom surface of floor structures❑Complies �. See the Envelope Assemblies table for values. I[FO12]3 incorporating radiant heating❑Does Not ;insulated to >=R-3.5.❑Not Observable: _❑Not Applicable Additional Comments/Assumptions: ------------------ _. 1 -High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Sawtell Apartments 18 plex Report date: 10/13/16 Data filename: S:\Scott\Year 2016\2016-120 Sawtell Apts\18 Plex\090116 146 N 1st W 18 Plex Apt Comcheck.- Page 3 of 8 'S�ptr,an p ; ; Frarrrmg FLoughIr1'Igspsntlnn 5e RBdY Ib __ . ConiPlles" ' Comm ents/A3sUmpttons , — C402.4.1, ;The building envelope contains a !❑Complies-`-`_ C402.4.2 continuous air barrierthat is sealed in -❑Does Not [FR16]1 ;an approved manner and either Observable ;constructed or tested in an approved❑Not Applicable imanner. Air barrier penetrations are❑Not sealed in an approved manner. '.C402.4.3,1.Factory-built fenestration and doors ❑Complies 6402.4:4 fare labeled as meeting air leakage ❑Does Not [FR1811 ,requirements. ❑Not Observable'.. --'-----_.._..._---- ❑Not Applicable C402.4.7 —---�....--------- ;Vestibules are installed on all building ❑Complies —__.-----------------------_--- --------'---------.. [FR17]3 !entrances. Doors have self-closing ❑Does Not devices. ❑Not Observable'.. ❑Not Applicable '.. C402.3.3, ;Vertical fenestration U -Factor. '❑Complies See the Envelope Assemblies table for values. C402.3.4❑Does Not [FR8]1❑Not Observable'.. ❑Not Applicable '.. C402.3.3 ;Vertical fenestration SHGC value. '.❑Complies See the Envelope Assemblies table for values [FR10]1 (❑Does Not '..❑Not Observable '.. �s ❑Not Applicable Fenestration products rated in;❑Complies ER1] =I]accordance with NFRC. ❑Does Not a; r ❑Not Observable'.. ❑Not Applicable C303.1.3 ;Fenestration products are certified as ❑Complies '.. [FR13]1 'to performance labels or certificates ❑Does Not ;provided. ❑Not Observable '.. ❑Not Applicable '.. q0 Mgnl7 ] U -factor of opaque doors associated ❑Complies see the Envelope Assemblies table for values (FR14J� N: with the building thermal envelope ❑Does Not u�]�. meets requirements' .:. ❑Not Observable nmnnl Applicable Additional Comments/Assumptions: — — 1 ,High Impact (Tier 1) 2. Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Sawtell Apartments 18 plex Report date: 10/13/16 Data filename: S:\Scott\Year 2016\2016-120 Sawtell Apts\18 Plex\090116 146 N 1st W 18 Plex Apt Comcheck.i Page 4 of 8 Additional Comments/Assumptions: --- 11High Impact (Tier 1) �2Medium Impact (Tier 2) T3 ILow Impact ier Project Title: Sawtell Apartments 18 plex Report date: 10/13/16 Data filename: S:\Scott\Year 2016\2016-120 Sawtell Apts\18 Plex\090116 146 N 1st W 18 Plex Apt Comcheck.i Page 5 of 8 5a4tlbn # Insuhation Ips]?eGt#an Complies' In men,iO C402.4.1. IAII sources of air leakage in the❑Complies 1 :building thermal envelope are sealed,❑Does Not [IN1]1 ;caulked, gasketed, weather stripped or wrapped with moisture vapor - ❑Not Observable permeable wrapping material to '..❑Not Applicable -: :minimize air leakage. C402.4.2. ,Roof R -value. For some Calling❑Complies See the Envelope Assemblies table for values. 1 systems, verification may need to❑Does Not [IN2]1 ;occur during Framing Inspection. !.❑Not Observable _ _ t❑Not Applicable C303.2 ;Roof insulation installed per -I❑Complies T [IN3]1 manufacturer's instructions. Blown or !❑Does Not ;poured loose -fill insulation is installed ?only where the roof slope is <=3 in❑Not Observable: 312.!❑Not Applicable C303.2 'Above -grade wall insulation installed !❑Complies [IN7]1 !per manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable ,Ki4Q 2 KfllFloor insulation R -value. ❑Complies See the Envelope Assemblies table for values. ❑Does Not ?a - R❑Not Observable: ❑Not Applicable Building envelope insulation is labeled ❑Complies [[N101 'sawith R -value or insulation certificate❑Does Not providing R -value and other relevant data. ❑Not Observable: ,, re❑Not Applicable L303 1 Exterior insulation is protected from❑Complies � GwN14] with a protective material. ❑Does Not nwmji,damage s :! Verification for exposed foundation :(Insulation may need to occur duringI❑Not y Observable': Foundation Inspection. _❑Not Applicable C402.2.1 Insulation intended to meet the roof❑Complies [IN17]3 ;Iinsulation requirements cannot be ❑Does Not installed on top of a suspended i❑Not Observable' ceiling. Mark this requirement '..compliant if insulation is installed❑Not Applicable ,. accordingly. Additional Comments/Assumptions: 1 High Impact (Tier 1) Z�Med!um Impact (Tier 2) 1 3�Low Impact (Tier 3) Project Title: Sawtell Apartments 18 plex Report date: 10/13/16 Data filename: S:\Scott\Year 2016\2016-120 Sawtell Apts\18 Plex\090116 146 N 1st W 18 Plex Apt Comcheck.i Page 6 of 8 Additional Comments/Assumptions: 1 (High Impact (Tier 1) 2= Medium Impact (Tier 2) 3 rrLow Impact (Tier 3) ..---- --- '--- .----- ---- --1..----._... -- ---I Project Title: Sawtell Apartments 18 plex Report date: 10/13/16 Data filename: SAScott\Year 2016\2016-120 Sawtell Apts\18 Plex\090116 146 N 1st W 18 Plex Apt Comcheck., Page 7 of 8 Project Title: Sawtell Apartments 18 plex Report date: 10/13/16 Data filename: SAScott\Year 2016\2016-120 Sawtell Apts\18 Plex\090116 146 N 1st W 18 Plex Apt Comcheck., Page 8 of 8