HomeMy WebLinkAboutPLANS - 17-00084 - 36 N Center St - Cell Tower DATE: 12-10-2016
DRAWN BY: JRC
CHECKED BY: LARSON QUICK
REVISIONS
DATE DESCRIPTION INT.
12.10.16 CD's (Prelim) JRC
12.13.16 CD's (Final) JRC
APPROVALS
GENERAL LOCATION MAP VICINITY MAP MODERNIZATION EQUIPMENT LIST
CONTACT INFORMATION
PROPERTY OWNER
PHOENIX TOWER INTERNATIONAL
1001 YAMATO ROAD, SUITE 102
BOCA RATON, FLORIDA 33431
SITE ACQUISITION FIRM
RAGE DEVELOPMENT LLC
2181 HUGO AVENUE
SALT LAKE CITY, UT 84117
A/E FIRM
SMITH HYATT ARCHITECTS
845 SOUTH MAIN STREET
BOUNTIFUL, UT 84010
NETWORK SYSTEMS OWNER
T-MOBILE
121 WEST ELECTION RD. STE. 330
DRAPER, UT 84020
LANDLORD
CONSTRUCTION
OPS MANAGER
RF ENGINEER
PROJECT MANAGER
APPROVED BY PRINT NAME DATEINITIALS
DRAWING
TITLE:
DRAWING NO.:
TITLE SHEET T-1
SL01403D
REXBURG CITY
12 NORTH MAIN STREET
REXBURG, ID 83440
PROPRIETY INFORMATION:
THE INFORMATION CONTAINED IN THIS
SET OF DRAWINGS IS PROPRIETARY BY
NATURE. ANY USE OR DISCLOSURE
OTHER THAN THAT WHICH RELATES TO
T-MOBILE SERVICES IS STRICTLY
PROHIBITED.
DISCLOSURE:
NO SITE WALK WAS CONDUCTED FOR
THESE DRAWINGS. DATA WAS PROVIDED
BY T-MOBILE.
CONTRACTOR TO VERIFY MATERIALS
AND DESIGN PRIOR TO INSTALL.
SMITH HYATT
ARCHITECTS
845 SOUTH MAIN, BOUNTIFUL, UTAH 84010
801-298-5777 FAX 801- 298-1677
SL
0
1
4
0
3
D
RE
X
B
U
R
G
C
I
T
Y
12
N
O
R
T
H
M
A
I
N
S
T
R
E
E
T
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
12-13-16
AR-26 1
THOMAS G. SMITH
7
SCOPE OF WORK
T-MOBLE IS PROPOSING TO REPLACE THREE (3) ANTENNAS AND ADD
SIX (6) RRUs AND TWO (2) HCS HYBRID LINE. FINAL TOWER
CONFIGURATION WILL BE NINE (9) ANTENNAS, THREE (3) TMAs, NINE (9)
RRUs, TWELVE (12) LINES OF COAX AND THREE (3) HYBRID FIBER LINES.
SITE LOCATION
SITE LOCATION
SECTOR TYPE MODEL QUANTITY
ALPHA ANTENNA AIR21 B2A/B4P (QUAD)1
ALPHA ANTENNA KRD901146/1AIR32 B66a/B2a
(OCTA)1
ALPHA ANTENNA APXVFWW24X-C-NA20 (HEX)1
ALPHA TMA STYLE 1B-TWIN AWS 1
ALPHA RRU RRUS32 B66A 1
ALPHA RRU RRUS32 B2 1
ALPHA RRU RRUS11 B12 1
ALPHA COAX 7/8"-90'4
BETA ANTENNA AIR21 B2A/B4P (QUAD)1
BETA ANTENNA KRD901146/1AIR32 B66a/B2a
(OCTA)1
BETA ANTENNA APXVFWW24X-C-NA20 (HEX)1
BETA TMA STYLE 1B-TWIN AWS 1
BETA RRU RRUS32 B66A 1
BETA RRU RRUS32 B2 1
BETA RRU RRUS11 B12 1
BETA COAX 7/8"-90'4
GAMMA ANTENNA AIR21 B2A/B4P (QUAD)1
GAMMA ANTENNA KRD901146/1AIR32 B66a/B2a
(OCTA)1
GAMMA ANTENNA APXVFWW24X-C-NA20 (HEX)1
GAMMA TMA STYLE 1B-TWIN AWS 1
GAMMA RRU RRUS32 B66A 1
GAMMA RRU RRUS32 B2 1
GAMMA RRU RRUS11 B12 1
GAMMA COAX 7/8"-90'4
SITE FIBER 9x18 HCS 1
SITE FIBER 6x12 HCS 2
DATE: 12-10-2016
DRAWN BY: JRC
CHECKED BY: LARSON QUICK
REVISIONS
DATE DESCRIPTION INT.
12.10.16 CD's (Prelim) JRC
12.13.16 CD's (Final) JRC
SMITH HYATT
ARCHITECTS
845 SOUTH MAIN, BOUNTIFUL, UTAH 84010
801-298-5777 FAX 801- 298-1677
SL
0
1
4
0
3
D
RE
X
B
U
R
G
C
I
T
Y
12
N
O
R
T
H
M
A
I
N
S
T
R
E
E
T
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
DRAWING
TITLE:
DRAWING NO.:
GENERAL
NOTES N-1
GENERAL CONSTRUCTION NOTES
DRAWINGS WERE PREPARED FROM STANDARDIZED DETAILS DEVELOPED AND
PROVIDED BY T-MOBILE WEST, LLC ("T-MOBILE"). STANDARDIZED DETAILS ARE TO BE
CONFIRMED AND CORRELATED AT THE SITE BY THE CONTRACTOR. STANDARDIZED
DETAILS THAT REQUIRE MODIFICATIONS DUE TO ACTUAL FIELD CONDITIONS AND
REQUIREMENTS MUST BE SUBMITTED TO, AND APPROVED BY, T-MOBILE PRIOR TO
START OF WORK.
DRAWINGS ARE NOT TO BE SCALED. WRITTEN DIMENSIONS TAKE PRECEDENCE. THIS
SET OF DOCUMENTS IS INTENDED TO BE USED FOR DIAGRAM PURPOSES ONLY.
UNLESS OTHERWISE NOTED. THE CONTRACTOR IS RESPONSIBLE FOR ALL
DIMENSIONS.
THE GENERAL CONTRACTOR'S SCOPE OF WORK SHALL INCLUDE FURNISHING ALL
MATERIALS, EQUIPMENT, LABOR, AND ANY REQUIREMENTS DEEMED NECESSARY TO
COMPLETE INSTALLATION AS DESCRIBED IN THE DRAWINGS AND AS DISCUSSED ON
THE SITE WALK.
PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS INVOLVED SHALL VISIT THE JOB
SITE TO FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE
PROPOSED PROJECT. CONTRACTORS SHALL VISIT THE CONSTRUCTION SITE WITH
THE CONSTRUCTION DOCUMENTS TO VERIFY FIELD CONDITIONS AND CONFIRM THAT
THE PROJECT WILL BE ACCOMPLISHED AS SHOWN. PRIOR TO PROCEEDING WITH
CONSTRUCTION, ANY ERRORS, OMISSIONS, OR DISCREPANCIES SHALL BE BROUGHT
TO THE ATTENTION OF T-MOBILE VERBALLY AND IN WRITING.
THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED
WITH CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY
DEFINED BY THE CONSTRUCTION DRAWINGS.
THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THE
CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR
ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND
PROCEDURES FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE
CONTRACT.
THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO
MANUFACTURER'S/VENDOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE OR
WHERE LOCAL CODES OR ORDINANCES TAKE PRECEDENCE.
ALL WORK PERFORMED ON THE PROJECT AND MATERIALS INSTALLED SHALL BE IN
STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND
ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS,
ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC
AUTHORITY, MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND
STATE JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF THE WORK.
GENERAL CONTRACTOR SHALL PROVIDE, AT THE PROJECT SITE, A FULL SET OF
CONSTRUCTION DOCUMENTS UPDATED WITH THE LATEST REVISIONS AND ADDENDA
OR CLARIFICATIONS FOR USE BY ALL PERSONNEL INVOLVED WITH THE PROJECT.
THE STRUCTURAL COMPONENTS OF ADJACENT CONSTRUCTION OR FACILITIES ARE
NOT TO BE ALTERED BY THIS CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE.
CONTRACTOR TO SEAL ALL PENETRATIONS THROUGH FIRE-RATED AREAS WITH U.L.
LISTED OR FIRE MARSHALL APPROVED MATERIALS IF APPLICABLE TO THIS FACILITY
AND OR PROJECT SITE.
CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT
LESS THAN 2-A OR 2-A10BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF
PROJECT AREA DURING CONSTRUCTION.
CONTRACTOR SHALL MEET ALL OSHA REQUIREMENTS FOR ALL INSTALLATIONS.
CONTRACTOR TO VERIFY LOCATION OF ALL BURIED UTILITIES PRIOR TO EXCAVATION.
CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING
IMPROVEMENTS, EASEMENTS, PAVING, CURBING, ETC. DURING CONSTRUCTION,
UPON COMPLETION OF WORK, CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY
HAVE OCCURRED DUE TO CONSTRUCTION ON OR ABOUT THE PROPERTY.
CONTRACTOR SHALL KEEP GENERAL WORK AREA CLEAN AND HAZARD FREE DURING
CONSTRUCTION AND DISPOSE OF ALL DIRT, DEBRIS, AND RUBBISH. CONTRACTOR
SHALL REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY OR
PREMISES. SITE SHALL BE LEFT IN CLEAN CONDITION DAILY AND FREE FROM PAINT
SPOTS, DUST, OR SMUDGES OF ANY NATURE.
THE ARCHITECTS/ENGINEERS HAVE MADE EVERY EFFORT TO SET FORTH IN THE
CONSTRUCTION AND CONTRACT DOCUMENTS THE COMPLETE SCOPE OF WORK.
CONTRACTORS BIDDING THE JOB ARE NEVERTHELESS CAUTIONED THAT MINOR
OMISSIONS OR ERRORS IN THE DRAWINGS AND OR SPECIFICATIONS SHALL NOT
EXCUSE SAID CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS
IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. THE BIDDER SHALL BEAR
THE RESPONSIBILITY OF NOTIFYING (IN WRITING) T-MOBILE OF ANY CONFLICTS,
ERRORS, OR OMISSIONS PRIOR TO SUBMISSION OF CONTRACTOR'S PROPOSAL. IN
THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL PRICE THE MORE COSTLY
OR EXTENSIVE WORK, UNLESS DIRECTED OTHERWISE.
THE CONTRACTOR SHALL PERFORM WORK DURING OWNER'S PREFERRED HOURS TO
AVOID DISTURBING NORMAL BUSINESS.
THE CONTRACTOR SHALL PROVIDE T-MOBILE CORPORATION PROPER INSURANCE
CERTIFICATES NAMING T-MOBILE WEST, LLC AS ADDITIONAL INSURED, AND T-MOBILE
WEST, LLC PROOF OF LICENSE(S) AND PL & PD INSURANCE.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
15.
16.
17.
18.
19.
CODE COMPLIANCE
ALL WORK AND MATERIALS SHALL BE PERFORMED
AND INSTALLED IN ACCORDANCE WITH THE
CURRENT CONDITIONS OF THE FOLLOWING CODES
AS ADOPTED BY THE LOCAL GOVERNING
AUTHORITIES. NOTHING IN THESE PLANS IS TO BE
CONSTRUED TO PERMIT WORK NOT CONFORMING
TO THESE CODES.
A. UTAH UNIFORM BUILDING STANDARD ACT
RULES
B. 2015 INTERNATIONAL BUILDING CODE (IBC)
C.2014 NATIONAL ELECTRIC CODE (NEC)
D. 2015 INTERNATIONAL BUILDING CODE (IBC)
E. 2015 INTERNATIONAL FIRE CODE (IFC)
F. 2012 INTERNATIONAL MECHANICAL CODE (IMC)
G. LOCAL BUILDING CODE
H. CITY OR COUNTY ORDINANCES
IMPORTANT NOTICE
THE EXISTING CONDITIONS
REPRESENTED HEREIN ARE BASED
ON VISUAL OBSERVATIONS AND
INFORMATION PROVIDED BY
OTHERS. A/E FIRM CANNOT
GUARANTEE THE CORRECTNESS
NOR THE COMPLETENESS OF THE
EXISTING CONDITIONS SHOWN AND
ASSUMES NO RESPONSIBILITY
THEREOF. THE CONTRACTOR SHALL
VISIT THE SITE AND VERIFY ALL
EXISTING CONDITIONS AS REQUIRED
FOR PROPER COMPLETION OF THE
PROJECT.
14.
12-13-16
AR-26 1
THOMAS G. SMITH
7
11
'
-
8
"
7'
-
6
"
DRAWING
TITLE:
DRAWING NO.:
EQUIPMENT
SITE PLAN A-1
KEY NOTESEXISTING EQUIPMENT SITE PLANPROPOSED EQUIPMENT SITE PLAN
SITE NOTES
DATE: 12-10-2016
DRAWN BY: JRC
CHECKED BY: LARSON QUICK
REVISIONS
DATE DESCRIPTION INT.
12.10.16 CD's (Prelim) JRC
12.13.16 CD's (Final) JRC
SL
0
1
4
0
3
D
RE
X
B
U
R
G
C
I
T
Y
12
N
O
R
T
H
M
A
I
N
S
T
R
E
E
T
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
SMITH HYATT
ARCHITECTS
845 SOUTH MAIN, BOUNTIFUL, UTAH 84010
801-298-5777 FAX 801- 298-1677
12-13-16
AR-26 1
THOMAS G. SMITH
7
T-MOBILE LEASE AREA
EXISTING 19" RACK
EXISTING FIBER BACKBOARD
1
2
3
4
6
5
EXISTING PBC 6500 CABINET
EXISTING RBS 3206 CABINET
EXISTING BULKHEAD
5
1. NO CHANGES PROPOSED TO EXISTING
CABINET LAYOUT
N
6
N
1
2
3
4
B
E
T
A
S
E
C
T
O
R
A
Z
I
M
U
T
H
1
7
0
°
ALP
H
A
S
E
C
T
O
R
AZI
M
U
T
H
3
0
°
GAMMA SECTOR
AZIMUTH 270°
3
80
'
C
E
N
T
E
R
L
I
N
E
1
80
'
C
E
N
T
E
R
L
I
N
E
2
1
B
E
T
A
S
E
C
T
O
R
A
Z
I
M
U
T
H
1
7
0
°
ALP
H
A
S
E
C
T
O
R
AZI
M
U
T
H
3
0
°
GAMMA SECTOR
AZIMUTH 270°
DATE: 12-10-2016
DRAWN BY: JRC
CHECKED BY: LARSON QUICK
REVISIONS
DATE DESCRIPTION INT.
12.10.16 CD's (Prelim) JRC
12.13.16 CD's (Final) JRC
SL
0
1
4
0
3
D
RE
X
B
U
R
G
C
I
T
Y
12
N
O
R
T
H
M
A
I
N
S
T
R
E
E
T
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
SMITH HYATT
ARCHITECTS
845 SOUTH MAIN, BOUNTIFUL, UTAH 84010
801-298-5777 FAX 801- 298-1677
DRAWING
TITLE:
DRAWING NO.:
TOWER
ELEVATION
AND PLAN A-1
EXISTING ANTENNA LAYOUTEXISTING TOWER SOUTH ELEVATION PROPOSED TOWER SOUTH ELEVATION
PROPOSED ANTENNA LAYOUT
KEY NOTES
N
N
EXISTING 80' MONOPOLE
EXISTING ANTENNAS (TO REMAIN),
TYPICAL OF (2) PER SECTOR, (3)
SECTORS TOTAL.
1
2
4
5
PROPOSED TMO REPLACEMENT
ANTENNAS, TYPICAL OF (1) PER
SECTOR, (3) SECTORS TOTAL
12-13-16
AR-26 1
THOMAS G. SMITH
7
4
ONE (1) EXISTING TMO TMA, TYPICAL
OF (1) PER SECTOR, (3) SECTORS
TOTAL, MOUNTED BEHIND ANTENNA
2
3
1
EXISTING ANTENNAS (TO BE
REPLACED), TYPICAL OF (1) PER
SECTOR, (3) SECTORS TOTAL.
3
2
6
THREE (3) EXISTING TMO RRUs,
TYPICAL OF (1) PER SECTOR, (3)
SECTORS TOTAL, MOUNTED BEHIND
ANTENNA
7
SIX (6) PROPOSED TMO RRUs,
TYPICAL OF (2) PER SECTOR, (3)
SECTORS TOTAL, MOUNTED BEHIND
ANTENNA
5
6
2
4
5
6
7
DATE: 12-10-2016
DRAWN BY: JRC
CHECKED BY: LARSON QUICK
REVISIONS
DATE DESCRIPTION INT.
12.10.16 CD's (Prelim) JRC
12.13.16 CD's (Final) JRC
SL
0
1
4
0
3
D
RE
X
B
U
R
G
C
I
T
Y
12
N
O
R
T
H
M
A
I
N
S
T
R
E
E
T
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
SMITH HYATT
ARCHITECTS
845 SOUTH MAIN, BOUNTIFUL, UTAH 84010
801-298-5777 FAX 801- 298-1677
DRAWING
TITLE:
DRAWING NO.:
EQUIPMENT
DETAIL A-3
ANTENNA DETAIL 1 ANTENNA DETAIL 2
RRUs DETAIL 4
ANTENNA DETAIL 3
ANTENNA DETAIL 4
12-13-16
AR-26 1
THOMAS G. SMITH
7
EXISTING - TO REMAIN
FRONT VIEW SIDE VIEW
TOP VIEW
56"
12"8.9"
56"
8.9"
12"
ERICSSON AIR21 B2A/B4P (Quad)
EXISTING - TO REMAIN
ERICSSON AIR32 B66Aa/B2a (OCTA)
TOP VIEW
SIDE VIEWFRONT VIEW
56.6"
12.9"8.7"
12.9"
8.7"
PROPOSED REPLACEMENT ANTENNA
RFS APXVFWW24X-C-NA20
FRONT VIEW SIDE VIEW
TOP VIEW
96"
11.8"7.9"
11.8"
7.9"
96"
EXISTING - TO BE REMOVED
COMMSCOPE
LNX-6515DS-A1M (DUAL)
TOP VIEW
SIDE VIEWFRONT VIEW
96.6"
11.9"7.1"
11.9"
7.1"