HomeMy WebLinkAboutPRODUCT INFO - 17-00298 - 210 N 1st E - Solar PanelsQ.PEAK BLK-G4.1 290-300 1 APT test conditions: Cells at -1500 V against grounded, with conductive me- tal foil covered module surface, 25 °C, 168 h 2 See data sheet on rear for further information. Q.ANTUM SOLAR MODULE ANTI PID TECHNOLOGY (APT) HOT-SPOT PROTECT (HSP) TRACEABLE QUALITY (TRA.Q ™) YIELD SECURITY EN 174 modules tested Best polycrystalline solar module 2014 Q.PRO-G2 235 MOD:27898 photon.info/laboratory    Quality Tested ID. 40032587 high reliability low degradation frequent product surveillance With its top performance and completely black design the new Q.PEAK BLK-G4.1 is the ideal solution for all residential rooftop applications thanks to its innovative cell technology Q.ANTUM. The world-record cell design was developed to achieve the best performance under real condi- tions – even with low radiation intensity and on clear, hot summer days. LOW ELECTRICITY GENERATION COSTS Higher yield per surface area and lower BOS costs thanks to higher power classes and an effi ciency rate of up to 18.3 %. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low-light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti-PID Technology1, Hot-Spot-Protect and Traceable Quality Tra.Q™. EXTREME WEATHER RATING High-tech aluminum alloy frame, certifi ed for high snow (5400 Pa) and wind loads (4000 Pa) regarding IEC. MAXIMUM COST REDUCTIONS Up to 10 % lower logistics costs due to higher module capacity per box. A RELIABLE INVESTMENT Inclusive 12-year product warranty and 25-year linear performance guarantee2. THE IDEAL SOLUTION FOR: Rooftop arrays on residential buildings UL 1703; VDE Quality Tested; CE-compliant; IEC 61215 (Ed.2); IEC 61730 (Ed.1) application class A Sp e c i f i c a t i o n s s u b j e c t t o t e c h n i c a l c h a n g e s © H a n w h a Q CE L L S Q . P E A K B L K - G 4 . 1 _ 2 9 0 - 3 0 0 _ 2 0 1 6 - 0 9 _ R e v 0 3 _ N A At least 98 % of nominal power during first year. Thereafter max. 0.6 % degradation per year. At least 92.6 % of nominal power up to 10 years. At least 83.6 % of nominal power up to 25 years. All data within measurement tolerances. Full warranties in accordance with the warranty terms of the Q CELLS sales organisation of your respective country. Typical module performance under low irradiance conditions in comparison to STC conditions (25 °C, 1000 W/m2). Hanwha Q CELLS America Inc. 300 Spectrum Center Drive, Suite 1250, Irvine, CA 92618, USA | TEL +1 949 748 59 96 | EMAIL inquiry@us.q-cells.com | WEB www.q-cells.us MECHANICAL SPECIFICATION Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE IRRADIANCE [W/m²] RE L A T I V E E F F I C I E N C Y [ % ] 200 400 600 800 1000 110 100 90 80 Irradiance [W/m²] Re l a t i v e e f f i c i e n c y [ % ] Format 65.7 in × 39.4 in × 1.26 in (including frame) (1670 mm × 1000 mm × 32 mm) Weight 41.45 lbs (18.8 kg) Front Cover 0.13 in (3.2 mm) thermally pre-stressed glass with anti-reflection technology Back Cover Composite film Frame Black anodized aluminum Cell 6 × 10 monocrystalline Q.ANTUM solar cells Junction box 2.60-3.03 in × 4.37-3.54 in × 0.59-0.75 in (66-77 mm × 111-90 mm × 15-19 mm), Protection class IP67, with bypass diodes Cable 4 mm² Solar cable; (+) ≥ 39.37 in (1000 mm), (-) ≥ 39.37 in (1000 mm) Connector Multi-Contact MC4 or MC4 intermateable, IP68 PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage VSYS [V]1000 (IEC) / 1000 (UL)Safety Class II Maximum Series Fuse Rating [A DC]20 Fire Rating C (IEC) / TYPE 1 (UL) Design load, push (UL)2 [lbs/ft2]75 (3600 Pa)Permitted module temperature on continuous duty − 40 °F up to +185 °F (− 40 °C up to +85 °C) Design load, pull (UL)2 [lbs/ft2]55.6 (2666 Pa)2 see installation manual QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION Number of Modules per Pallet 32 Number of Pallets per 53' Container 30 Number of Pallets per 40' Container 26 Pallet Dimensions ( L × W × H )68.7 in × 45.3 in × 46.1 in (1745 mm × 1150 mm × 1170 mm) Pallet Weight 1435 lbs (651 kg) NOTE: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. EN RE L A T I V E E F F I C I E N C Y CO M P A R E D T O N O M I N A L P O W E R [ % ] 100 95 90 85 80 75 155 2520010 YEARS 98 Q CELLS Industry standard for tiered warranties* Industry standard for linear warranties* *Standard terms of guarantee for the 10 PV companies with the highest production capacity in 2014 (as at: September 2014) NA DETAIL A 0.630" (16 mm) 0.335" (8.5 mm)0.965" (24.5 mm) Junction bo× Product label 38.58" (980 mm)65.7" (1670 mm) 4 × Fastening points (DETAIL A) Cable with connectors Frame 5.90" (150 mm) 39.4" (1000 mm) 37.44" (951 mm) 1.26" (32 mm) 8 × Drainage holes 6 × Grounding points ø 0.177" (4.5 mm) 39.37" (1000 mm) 13.6“ (345 mm) ELECTRICAL CHARACTERISTICS POWER CLASS 290 295 300 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / -0 W) Mi n i m u m Power at MPP2 PMPP [W]290 295 300 Short Circuit Current*ISC [A]9.63 9.70 9.77 Open Circuit Voltage*VOC [V]39.19 39.48 39.76 Current at MPP*IMPP [A]9.07 9.17 9.26 Voltage at MPP*VMPP [V]31.96 32.19 32.41 Efficiency2 η [%]≥ 17.4 ≥ 17.7 ≥ 18.0 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NOC3 Mi n i m u m Power at MPP 2 PMPP [W]214.4 218.1 221.8 Short Circuit Current*ISC [A]7.77 7.82 7.88 Open Circuit Voltage*VOC [V]36.65 36.92 37.19 Current at MPP*IMPP [A]7.12 7.20 7.27 Voltage at MPP*VMPP [V]30.12 30.30 30.49 11000 W/m², 25 °C, spectrum AM 1.5 G 2 Measurement tolerances STC ± 3 %; NOC ± 5 % 3 800 W/m², NOCT, spectrum AM 1.5 G * typical values, actual values may differ Certified UL 1703 (254141) TEMPERATURE COEFFICIENTS Temperature Coefficient of ISC α [% / K]+ 0.04 Temperature Coefficient of VOC β [% / K]− 0.28 Temperature Coefficient of PMPP γ [% / K]− 0.39 Normal Operating Cell Temperature NOCT [°F]113 ± 5.4 (45 ± 3 °C) SolarEdge Single Phase Inverters for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US IN V E R T E R S www.solaredge.usUSA-CANADA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-UK-ISRAEL-TURKEY-SOUTH AFRICA-BULGARIA Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Record-breaking efficiency Integrated Arc Fault protection and Rapid Shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 Extremely small High reliability without any electrolytic capacitors Built-in module-level monitoring Outdoor and indoor installation Optional: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) 12-25 © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 03/2017. V.01. Subject to change without notice. Single Phase Inverters for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US OUTPUT  Rated AC Power Output 3000 3800 5000 6000 7600 VA Max. AC Power Output 3000 3800 5000 6000 7600 VA AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229) --3 --Vac AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264) 3 3 3 3 3 Vac AC Frequency (Nominal)59.3 - 60 - 60.5(1)Hz Maximum Continuous Output Current 208V --24 --A Maximum Continuous Output Current 240V 12.5 16 21 25 32 A GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes INPUT  Maximum DC Power 4650 5900 7750 9300 11800 W Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current 208V --15.5 --Adc Maximum Input Current 240V 8.5 10.5 13.5 16.5 20 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 % Nighttime Power Consumption < 2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Data, ANSI C12.20 Optional(2) Rapid Shutdown - NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21(3), Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS  AC Output Conduit Size / AWG Range 0.75-1” Conduit / 14-6 AWG DC Input Conduit Size / # of Strings / AWG Range 0.75-1” Conduit /1-2 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 in / mm Weight with Safety Switch 25.3 / 11.5 lb / kg Noise < 25 dBA Cooling Natural Convection Operating Temperature Range -13 to +140 / -25 to +60(4) (-40˚F / -40˚C option)(5)˚F / ˚C Protection Rating NEMA 3R (Inverter with Safety Switch) (1) For other regional settings please contact SolarEdge support (2) Revenue grade inverter P/N: SExxxxH-US000NNC2(3) Pending certification(4) Power de-rating from 50˚C(5) -40 version P/N: SExxxxH-US000NNU4 PO W E R O P T I M I Z E R SolarEdge Power Optimizer Module Add-On P300 / P350 / P404 / P405 / P500 PV power optimization at the module-level Up to 25% more energy Superior efficiency (99.5%) Mitigates all types of modules mismatch-loss, from manufacturing tolerance to partial shading Flexible system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module level monitoring Module-level voltage shutdown for installer and firefighter safety www.solaredge.comUSA - CANADA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - AUSTRALIA - THE NETHERLANDS - UK - ISRAEL © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 12/2015. V.01. Subject to change without notice. P300 (for 60-cell modules) P350 (for high-power 60-cell and for 72-cell modules) P500 (for 96-cell modules) P404 (for 60-cell and 72-cell, short strings) P405 (for thin film modules) INPUT Rated Input DC Power(1)300 350 500 405 405 W Absolute Maximum Input Voltage (Voc at lowest temperature)48 60 80 80 125 Vdc MPPT Operating Range 8 - 48 8 - 60 8 - 80 12.5 - 80 12.5 - 105 Vdc Maximum Continuous Input Current (Isc)10 11 10.1 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 RoHS Yes Fire Safety VDE-AR-E 2100-712:2013-05 INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions (W x L x H) 128 x 152 x 27.5 / 5 x 5.97 x 1.08 128 x 152 x 35 / 5 x 5.97 x 1.37 128 x 152 x 43 / 5 x 5.97 x 1.69 128 x 152 x 50 / 5 x 5.97 x 1.96 mm / in Weight (including cables) 760 / 1.7 830 / 1.8 994 / 2.1 1064 / 2.3 gr / lb Input Connector MC4(2) Output Connector MC4 Output Wire Length 0.95 / 3.0 1.2 / 3.9 m / ft Operating Temperature Range -40 - +85 / -40 - +185 ˚C / ˚F Protection Rating IP68 / NEMA6P Relative Humidity 0 - 100 % SolarEdge Power Optimizer Module Add-On P300 / P350 / P404 / P405 / P500 (1) Rated STC power of the module. Module of up to +5% power tolerance allowed. (2) For other connector types please contact SolarEdge. PV SYSTEM DESIGN USING A SOLAREDGE INVERTER(3)SINGLE PHASE THREE PHASE Minimum String Length (Power Optimizers) P300,P350,P500 8 16 P404,P405 6 13 Maximum String Length (Power Optimizers)25 50 Maximum Power per String 5250 11250 W Parallel Strings of Different Lengths or Orientations Yes (3) It is not allowed to mix P404/P405 with P300/P350/P500/P600/P700 in one string. Tech Brief Simplified Grounding for Every Application The UFO family of components eliminates the need for separate grounding hardware by bonding solar modules directly to IronRidge XR Rails. All system types that feature the UFO family—Flush Mount, Tilt Mount and Ground Mount—are fully listed to the UL 2703 standard. UFO hardware forms secure electrical bonds with both the module and the rail, resulting in many parallel grounding paths throughout the system. This leads to safer and more reliable installations. UFO Family of Components Universal Fastening Object (UFO) The UFO securely bonds solar modules to XR Rails. It comes assembled and lubricated, and can fit a wide range of module heights. Stopper Sleeve The Stopper Sleeve snaps onto the UFO, converting it into a bonded end clamp. Bonded Splice Each Bonded Splice uses self-drilling screws to form a secure connection. No bonding strap needed. Bonded Attachments The bonding bolt attaches and bonds the L-foot to the rail. It is installed with the same socket as the rest of the system. Grounding Lug A single Grounding Lug connects an entire row of PV modules to the grounding conductor. System Diagram UL Certification The IronRidge Flush Mount, Tilt Mount, and Ground Mount Systems have been listed to UL 2703 by Intertek Group plc. UL 2703 is the standard for evaluating solar mounting systems. It ensures these devices will maintain strong electrical and mechanical connections over an extended period of time in extreme outdoor environments. © 2016 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.0 Tech Brief Cross-System Compatibility Feature Flush Mount Tilt Mount Ground Mount XR Rails XR1000 Only UFO/Stopper  Bonded Splice N/A Grounding Lugs 1 per Row 1 per Row 1 per Array Microinverters & Power Optimizers Enphase - M250-72, M250-60, M215-60, C250-72 Darfon - MIG240, MIG300, G320, G640 SolarEdge - P300, P320, P400, P405, P600, P700, P730 Fire Rating Class A Class A N/A Modules Tested or Evaluated with over 400 Framed Modules Refer to installation manuals for a detailed list. í Approved Enphase microinverters can provide equipment grounding of IronRidge systems, eliminating the need for grounding lugs and field installed equipment ground conductors (EGC). A minimum of two microinverters mounted to the same rail and connected to the same Engage cable is required. Refer to installation manuals for additional details. Go to IronRidge.com/UFO Tech Brief The Strongest Attachment in Solar IronRidge FlashFoot2 raises the bar in solar roof protection. The unique water seal design is both elevated and encapsulated, delivering redundant layers of protection against water intrusion. In addition, the twist-on Cap perfectly aligns the rail attachment with the lag bolt to maximize mechanical strength. FlashFoot2 Twist-On Cap FlashFoot2’s unique Cap design encapsulates the lag bolt and locks into place with a simple twist. The Cap helps FlashFoot2 deliver superior structural strength, by aligning the rail and lag bolt in a concentric load path. Single Socket Size A custom-design lag bolt allows you to install FlashFoot2 with the same 7/16” socket size used on other Flush Mount System components. Three-Tier Water Seal FlashFoot2’s seal architecture utilizes three layers of protection. An elevated platform diverts water away, while a stack of rugged components raises the seal an entire inch. The seal is then fully-encapuslated by the Cap. FlashFoot2 is the first solar attachment to pass the TAS-100 Wind-Driven Rain Test. Water-Shedding Design An elevated platform diverts water away from the water seal. © 2016 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.0 Tech Brief Installation Features Testing & Certification Structural Certification Designed and Certified for Compliance with the International Building Code & ASCE/SEI-7. Water Seal Ratings Water Sealing Tested to UL 441 Section 27 “Rain Test” and TAS 100-95 “Wind Driven Rain Test” by Intertek. Ratings applicable for composition shingle roofs having slopes between 2:12 and 12:12. UL 2703 Conforms to UL 2703 Mechanical and Bonding Requirements. See Flush Mount Install Manual for full ratings. Alignment Markers Quickly align the flashing with chalk lines to find pilot holes. Rounded Corners Makes it easier to handle and insert under the roof shingles. Reinforcement Ribs Help to stiffen the flashing and prevent any bending or crinkling during installation. A B C E B C Benefits of Concentric Loading Traditional solar attachments have a horizontal offset between the rail and lag bolt, which introduces leverage on the lag bolt and decreases uplift capacity. FlashFoot2 is the only product to align the rail and lag bolt. This concentric loading design results in a stronger attachment for the system. A Flush Mount System Strength Tested All components evaluated for superior structural performance. PE Certified Pre-stamped engineering letters available in most states. Class A Fire Rating Certified to maintain the fire resistance rating of the existing roof. Design Assistant Online software makes it simple to create, share, and price projects. UL 2703 Listed System Entire system and components meet newest effective UL 2703 standard. 20-Year Warranty Twice the protection offered by competitors. Built for solar’s toughest roofs. IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Datasheet © 2016 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.20 XR Rails Attachments Datasheet Design Assistant Go from rough layout to fully engineered system. For free. Go to IronRidge.com/design Resources XR100 Rail The ultimate residential solar mounting rail. • 8’ spanning capability • Heavy load capability • Clear & black anod. finish Bonded Splices All rails use internal splices for seamless connections. • Self-drilling screws • Varying versions for rails • Forms secure bonding XR10 Rail A low-profile mounting rail for regions with light snow. • 6’ spanning capability • Moderate load capability • Clear & black anod. finish XR1000 Rail A heavyweight mounting rail for commercial projects. • 12’ spanning capability • Extreme load capability • Clear anodized finish FlashFoot2 Flash and mount XR Rails with superior waterproofing. • Twist-on Cap eases install • Wind-driven rain tested • Mill & black finish Drop-in design for rapid rail attachment. • Secure rail connections • Slot for vertical adjusting • Clear & black anod. finish Raise Flush Mount System to various heights. • Works with vent flashing • 4” and 7” lengths • Ships assembled Slotted L-Feet Flush Standoffs Clamps & Grounding UFOs Universal Fastening Objects bond modules to rails. • Fully assembled & lubed • Single, universal size • Clear & black finish Stopper Sleeves Snap onto the UFO to turn into a bonded end clamp. • Bonds modules to rails • 6 different sizes • Clear & black anod. finish Grounding Lugs Connect arrays to equipment ground. • Low profile • Single tool installation • Mounts in any direction Microinverter Kits Mount MIs or POs to XR Rails. • Bonds devices to rails • Kit comes assembled • Listed to UL 2703 NABCEP Certified Training Earn free continuing education credits, while learning more about our systems. Go to IronRidge.com/training Bond and attach XR Rails to certified attachments. • T & Square Bolt options • Nut uses 7/16” socket • Assembled & lubricated Bonding Hardware C O NTINUING E D U C A T I O N R E G I S T E R E D PROVID E R Tech Brief Solar Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. XR Rails are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently transfer loads into the building structure. Their superior spanning capability requires fewer roof attachments, reducing the number of roof penetrations and the amount of installation time. XR Rail Family Force-Stabilizing Curve Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails is specially designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. Compatible with Flat & Pitched Roofs Roof Mount utilizes XR Rails, along with optional all-in-one attachments, to secure systems flush against residential roofs. Corrosion-Resistant Materials XR Rails are compatible with FlashFoot and other pitched roof attachments. IronRidge offers a range of tilt leg options for flat roof mounting applications. All XR Rails are made of marine-grade aluminum alloy, then protected with an anodized finish. Anodizing prevents surface and structural corrosion, while also providing a more attractive appearance. XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. © 2014 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.12 Tech Brief Rail Selection The following table was prepared in compliance with applicable engineering codes and standards. Values are based on the following criteria: ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean %uilding Height of 0 ft. 9isit IronRidge.com for detailed span tables and certifications. Load Rail Span Snow (PSF)Wind (MPH)4’5’ 4”6’8’10’12’ None 100 120 140 XR10 XR100 XR1000 160 10-20 100 120 140 160 30 100 160 40 100 160 50-70 160 80-90 160 XR100 XR100 is the ultimate residential mounting rail. It supports a range of wind and snow conditions, while also maximizing spans up to 8 feet. • 8’ spanning capability • Heavy load capability • Clear & black anodized finish • Internal splices available XR10 XR0 is a sleek, low-profile mounting rail, designed for regions with light or no snow. It achieves 6 foot spans, while remaining light and economical. • 6’ spanning capability • Moderate load capability • Clear & black anodized finish • Internal splices available XR1000 XR1000 is a heavyweight among solar mounting rails. It’s built to handle extreme climates and spans 12 feet or more for commercial applications. • 12’ spanning capability • Extreme load capability • Clear anodized finish • Internal splices available PV P H O T O V OL T A I C W I R E 60 0 V O L T W EIG HTS, MEASUREM E N T S A ND PACK A G I N G AWG SIZE NO. OF STRANDS INSULATION THICKNESS NOMINAL O.D.NET WEIGHT 14 19 0.060 0.190 26.8 12 19 0.060 0.207 36.1 10 19 0.060 0.231 50.6 8 19 0.075 0.292 80.3 14 7 0.060 0.190 26.8 12 7 0.060 0.207 36.1 10 7 0.060 0.231 50.6 8 7 0.075 0.292 80.3 t Stranded copper conductors t XLP insulation t UL Subject 4703 t UL 44 t UL 854 t For use in solar power applications t Rated 90°C for exposed or concealed wiring in wet or dry locations t Rated for direct burial A PPLICATIONS Suitable for use as follows: t Southwire PV Photovoltaic Wire is manufactured using stranded copper conductors with single layer XLP insulation t Bare or Tinned Conductors t -40°C to +90°C t Sunlight Resistant t RoHS Compliant t Direct Burial t Sample Print Legend: SOUTHWIRE E316464 (O) (UL) PV WIRE 10 AWG (5.26mm2) CU 600V 90˚C WET OR DRY (-40˚C) SUN RES DIRECT BURIAL VW-1 OR USE-2 600V OR RHW-2 600V — RoHS SPECIF ICATIONS CONSTRU CTION Bare or Tinned Stranded Copper Conductors XLP Insulation Direct Burial -40°C to +90°C 600 Volts STRANDED COPPER CONDUCTORS PV PHOTOVOLTAIC WIRE 600 VOLT Other sizes and strand configurations are available upon request. Also available in various colors.