HomeMy WebLinkAboutCOMPLIANCE CERTIFICATE 2 - 16-00293 - Rigby Eye Care* 16-100243
COMcheck Software Version 4.3.4
Envelope Compliance Certificate
Project Information
Energy Code:
Project Title:
Location:
Climate Zone:
Project Type:
Vertical Glazing/ Wall Area:
Construction Site:
711 Rigby Lake Drive, Unit # 3
Rigby, Idaho 83442
Building Area
20121ECC
Rigby Eye Care
Rigby, Idaho
6b
New Construction
13%
Owner/Agent:
Floor Area
Designer/Contractor:
rvmce : Nonresidential 5394
Additional Efficiency Package
Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations.1.
Envelope Assemblies
Assembly
Gross Area
Cavity
Cont.
Proposed
Budget U.
0.051
or
R -Value
R -Value
IU -Factor
Factory.)
Door: , Perf. Type: Energy code default, Double Pane with Low -E,
Perimeter
Tinted, SHGC 0.60, [Bldg. Use 1 -Office]
42 — —
Roof: Attic Roof, Wood Joists, [Bldg. Use 1 - Office]
0.770
Door: , Pert. Type: Energy code default, Double Pane with Low -E,
Floor: Wood -Framed, [Bldg. Use 1 - Office]
5394
0.0
50.0
0.019
0.021
5394
0.0
19.0
0.044
0.033
NORTH
Ext. Wall: Wood -Framed, 161n. o.c., [Bldg. Use 1 - Office]
Window: Wood Frame, Pert. Specs.: Product ID North Fixed, SHGC
906
22.0
2.5
0.051
0.051
0.58, [Bldg. Use 1 - Office] (b)
48
—
—
0.280
0.360
Basement: Solid Concrete, Sin. Thickness, Normal Density, Furring:
Wood, Wall Ht 7.5, Depth B.G. 7.0, [Bldg. Use 1 - Office]
240
11.0
6.0
0.062
0.108
EAST
Ext. Wall: Wood -Framed, 161n. o.c., [Bldg. Use 1 - Office] 688 22.0 2.5 0.051 0.051
Window: Wood Frame, Perf. Specs.: Product ID East Fixed, SHGC 70
0.58, [Bldg. Use 1 - Office] (b) — — 0.280 0.360
Basement: Solid Concrete, Bin. Thickness, Normal Density, Furring:
Wood, Wall Ht 7.5, Depth B.G. 7.5, [Bldg. Use 1 - Office]390 11.0 6.0 0.062 0.108
SOUTH
Ext. Wall: Wood -Framed, 16in, o.c., [Bldg. Use 1 - Office]
935
Window: Wood Frame, Perf. Specs.: Product ID South Fixed, SHGC
22.0 2.5
0.051
0.051
0.58, [Bldg. Use 1 - Office] (b)
140 — —
0.280
0.360
Door: , Perf. Type: Energy code default, Double Pane with Low -E,
Tinted, SHGC 0.60, [Bldg. Use 1 -Office]
42 — —
0.800
0.770
Door: , Pert. Type: Energy code default, Double Pane with Low -E,
Tinted, SHGC 0.60, [Bldg. Use 1 -Off
21 — --
0.800
0.770
Basement: Solid Concrete, Bin. Thickness, Normal Density, Furring:
Wood, Wall Ht 7.5, Depth B.G. 7.0, [Bldg. Use 1 - Office]
240 11.0 6.0
0.062
0.108
Project Title: Rigby Eye Care
Data filename: Report date: 04/11/16
Page 1 of 20
Assembly
Gross Area
Cavity
Cont.
Proposed
Budget U -
or
R -Value
R -Value
U -Factor
Factorrr
Perimeter
WEST
Ext. Wall: Wood -Framed, 161n. o.c., [Bldg. Use 1 -Office]
623
22.0
2.5
0.051
0.051
Door: Insulated Metal, Non -Swinging, [Bldg. Use 1 - Office]
21
—
—
0.280
0.280
Window: Wood Frame, Pert. Specs.: Product ID West Fixed, SHGC
80
—
—
0.280
0.360
0.58, [Bldg. Use 1 - Office] (b)
Basement: Solid Concrete, Bin. Thickness, Normal Density, Furring:
405
11.0
6.0
0.062
0:108
Wood, Wall Ht 7.5, Depth B.G. 7.5, [Bldg. Use 1 - Office]
(a) Budget U -factors are used for software baseline calculations ONLY, and are not code requirements.
(b) Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation.
Envelope Design better than code
Envelope Compliance Statement
Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed envelope systems have been
designed to meet the 2012 IECC requirements in COMcheck Version 4.3.4 and to comply with the mandatory requirements listed
in the Inspection Checklist.
� 11 zo/(o
Date
Project Title: Rigby Eye Care Report date: 04/11/16
Data filename: Page 2 of 20
�( COMcheck Software Version 4.3.4
Interior Lighting Compliance Certificate
Project Information
Energy Code:
Project Title:
Project Type:
2012 IECC
Rigby Eye Care
New Construction
Construction Site: Owner/Agent:
711 Rigby Lake Drive, Unit # 3
Designer/Contractor:
Rigby, Idaho 83442
Additional Efficiency Package
Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations.
Allowed Interior Lighting Power
A B C D
Area Category Floor Area Allowed Allowed Wafts
(ft2) Watts / ft2
1 -Office
5394 0.85
4585
Total Allowed Wafts =
4585
Proposed Interior Lighting Power
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
B C D
Lamps/ # of Fixture
E
(C X D)
Fixture Fixture Watt.
1 -Office
LED: ceiling can trim: LED Trim: LED PAR 11 W:
Linear Fluorescent: corridor track: 2 bulb Flourescent: 48" T8 32W (Super T8): Electronic:
1 88 11
968
2 14 32
448
Track Lighting: Wattage based on 52 feet of track
0
Linear Fluorescent: lights: 4 bulb Flourescent: 48" T8 32W: Electronic:
0 0
1560
LED: wall sconce: LED Wall Mount: LED Linear Lamp 8W:
4 7 32
224
1 6 11
66
Total Proposed Wafts =
3266
compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been
designed to meet the 2012 IECC requirements in COMcheck Version 4.3.4 and to comply with the mandatory requirements listed
in the Inspection Checklist.
1-.Ja1 uim: nigoy eye care Report date: 04/11/16
Data filename:
Page 3 of 20
COMcheck Software Version 4.3.4
Exterior Lighting Compliance Certificate
ProJect Information
Energy Code:
Project Title:
Project Type:
Exterior Lighting Zone
Construction Site:
711 Rigby Lake Drive, Unit # 3
Rigby, Idaho 83442
Allowed Exterior Lighting Power
A
Area/Surface Category
2012 IECC
Rigby Eye Care
New Construction
2 (Neighborhood business district)
Owner/Agent:
B
Quantity
Designer/Contractor:
C D E
Allowed Tradable Allowed Watts
Watts / Wattage B X C
Illuminated length of facade wall or surface
13
234
( )
Main entry
300 ft
2.5 No
750
Other door (not main entry)
10 It of
20 Yes
200
3 It of door
20 Yes
60
Total Tradable Watts (a) =
260
Total Allowed Watts =
1010
(a) Wattage tradeoffs are only allowed between tradable
areas/surfaces.Total Allowed Supplemental Watts (b) =
600
(b) A supplemental allowance equal to 600 watts
may be applied toward compliance of both
non4radable and tradable areas/surfaces.
Proposed Exterior Lighting Power
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
Illuminated lenath of facade wall or 5urface (3Q0 ft) Non tragi/ tt ae
LED. Soffit Can. Recess LED Can: LED Other Fixture Unit 13W:
LED: Downcast Lamp: Gooseneck LED bulb: LED A Lamp 2.5W.
Main entry (10 ftof door Width),Trn/ansae
LED: Entry Can: Recess LED Can: LED Other Fixture Unit 13W:
LED: Entry Wall: Entry Wall Mount: LED Other Fixture Unit 6.5W:
Other door (not main entry) (3 ft of door idth)Inaclable Wni
LED: Soffit Can: Recess LED Can: LED Other Fixture Unit 13W:
B C D E
Lamps/ # of Fixture (C X D)
Fixture Fixture Watt.
1 18
13
234
1 6
13
78
1 4
13
52
1 4
13
52
1 2 13 26
Total Tradable Proposed Watts = 130
Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have been
designed to meet the 2012 IECC requirements in COMcheck Version 4.3.4 and to comply with the mandatory requirements listed
in the Inspection Checklist.
Project Title: Rigby Eye Care
Data filename:
Report date: 04/11/16
Page 4 of 20
COMcheck Software Version 4.3.4
Mechanical Compliance Certificate
Project Information
Energy Code:
2012 IECC
Project Title:
Rigby Eye Care
Location:
Rigby, Idaho
Climate Zone:
6b
Project Type:
New Construction
Construction Site: Owner/Agent:
711 Rigby Lake Drive, Unit # 3 Designer/Contractor:
Rigby, Idaho 83442
Additional Efficiency Package
Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations.
Mechanical Systems List
Quantity System Type & Description
1 HVAC System (Single Zone):
Heating: 1 each - Central Furnace, Gas, Capacity = 84 kBtu/h
Proposed Efficiency = 96.00% Et, Required Efficiency = 80.00% Et
Cooling: 1 each - VRF Zone Fan Unit, Capacity = 50 kStu/h, Air Economizer
No minimum efficiency requirement applies
1 HVAC System (Multiple -Zone):
Heating: 2 each - Central Furnace, Gas, Capacity = 106 kBtu/h
Proposed Efficiency = 98.00% EL Required Efficiency = 80.00% Et
Cooling: 2 each - VRF Zone Fan Unit, Capacity = 60 kBtu/h, No Economizer, Economizer exception: None
No minimum efficiency requirement applies
2 Water Heater:
Gas Storage Water Heater, Capacity: 50 gallons, Input Rating: 75 Btu/h
Proposed Efficiency: 0.85 EF, Required Efficiency: 0.58 EF
Mechanical Compliance Statement
Compliance statement: The proposed mechanical design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been
designed to meet the 2012 IECC requirements in COMcheck Version 4.3.4 and to comply with the mandatory requirements listed
in the Inspection Checklist.
Project Title: Rigby Eye Care
Data filename: Report date: 04/11/16
Page 5 of 20
COMcheck Software Version 4.3.4
Inspection Checklist
Energy Code: 2012 IECC
Requirements: 100.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
#
& Re .ID
Plan Review
Complies?
,Comments/Assumptions
C103.2
[PRl11
Plans and/or specifications provide all
information with which compliance
[Complies
❑Does Not
Requirement will be met.
can be determined for the building
envelope and document where
❑Not Observable
exceptions to the standard are
❑Not Applicable
claimed.
C103.2
[PR211
Plans, specifications, and/or
calculations provide all information
❑Complies
❑Does Not
Requirement will be met.
with which compliance can be
determined for the mechanical
[--]Not Observable
systems and equipment and
❑Not Applicable
document where exceptions to the
standard are claimed. Load
calculations per acceptable
engineering standards and
handbooks.
C103.2 Plans, specifications, and/or ❑Complies
[PR331 calculations provide all information ❑Does Not
Requirement will be met.
with which compliance can be
determined for the service water ❑Not Observable
heating systems and equipment and []Not Applicable
document where exceptions to the
standard are claimed. Hot water
system sized per manufacturer's
sizing guide.
C103.2 Plans, specifications, and/or ❑Complies Requirement will be met.
[PR411 calculations provide all information ❑Does Not
with which compliance can be
determined for the interior lighting ❑Not Observable
and
electrical systems and equipment ❑Not Applicable
and
document where exceptions to
the
standard are claimed. Information
provided
should include interior
lighting
power calculations, wattage of
bulbs
and ballasts, transformers and
control devices.
0103.2 Plans, specifications, and/or ❑Complies Requirement will be met.
[PR8j1 calculations provide all information ❑Does Not
with which compliance can be
determined for the exterior lighting ❑Not Observable
and
electrical systems and equipment ❑Not
Applicable
and
document where exceptions to
the standard are claimed. Information
provided
should include exterior
lighting power calculations, wattage of
bulbs
and ballasts, transformers and
control devices.
C406 Plans, specifications, and/or ❑Complies Requirement will be met.
[PR911 calculations provide all information ❑Does Not
with
which compliance can be
determined for the additional energy ❑Not
Observable
efficiency package options. ❑Not Applicable
I 1 [High Impact (Tier 1) 12 1 Medium Impac]Tier2) 3 Low Impact(Tier 3)
Project Title: Rigby Eye Care Report date: 04/11/16
Data filename:
Page 6 of 20
Section
#
& Re .ID
Plan Review
Complies?
Comments/Assumptions
[40203.1
[PR10]1
j Vertical fenestration area �= 30
;percent of the gross above-grade wall
❑Complies
❑Does Not
Requirement will be met.
I a rea.
❑Not Observable
❑Not Applicable
[402.3.1 ;Skylight
[PR11]1 'gross
area <= 3 percent of the
roof area.
❑Complies
Requirement will be met.
❑Does Not
❑Not Observable
❑Not Applicable
Et
Areas with obstructions that block Complies
direct beam sunlight on >= 1/2 of the ❑Does Not
Exception: Requirement does nota I
apply.
roof over the enclosed area for more
han 1,500 daytime hours per year ❑Not Observable
between 8 am and 4 pm. ❑Not Applicable
Project Title:
Data filename:
a.vnuff le"WNssu mptions:
1 High Impact (Tier 1) ,2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Rigby Eye Care
Report date: 04/11/16
Page 7 of 20
1 High Impact (Tier 1) 2.: Medium Impact (Tier 2) 3 Low Impact (Tier 3)
P '
roject Title: Rigby Eye Care
Data filename: Report date: 04/11/16
Page 8 of 20
Section
#
Framing / Rough -in Inspection
Plans Verified
Value
Field Verified
i< Value
Complies?
Comments/Assumptions
Reg.ID.
0402.4.1,
;The building envelope contains a
= ❑Complies
Requirement will be met.
0402.4.2
continuous air barrier that is
i'[]Does Not
[FR1611
(sealed in an approved manner
and either constructed or tested
[__]Not Observable
in an approved manner. Air
,.. "❑Not Applicable
barrier penetrations are sealed in
x
,an approved manner,
C402.4.3,
Factory -built fenestration and
� ❑Complies
Requirement will be met.
C402.4.4
doors are labeled as meeting air
,'�E]Does Not
[FR18]3
leakage requirements.
❑Not Observable
�.❑Not Applicable
0402.4.7
Vestibules are installed on all
_ ,❑Complies
Exception: Doors that open
[FR17]3
building entrances. Doors have`,❑Does
Not
directly from a space =3000
self-closing devices.
j❑Not Observable
ft2.
�!❑Not Applicable
C402.3.3,
Vertical fenestration U -Factor.
U-_ U- ❑Complies
See the Envelope Assemblies
C402.3.4
❑Does Not
table for values.
[FR8]1
❑Not Observable
❑Not Applicable
C402.3.3
Vertical fenestration SHGC value.
SHGC:_ SHGC:_ ❑Complies
See the Envelope Assemblies
[FR10]1
❑Does Not
table for values.
[_-]Not Observable
❑Not Applicable
C303.1.3
Fenestration products rated in
-EIC plies
Requirement will be met.
[FR12p '
accordance with NFRC.
�z r ❑Does Not
' ❑Not Observable
❑Not Applicable
C303.1.3
Fenestration products are
" Elco mplies
Requirement will be met.
[FR13]1
certified as to performance labels .
�. `^`"_ + ` ;, ,h❑Does Not
or certificates provided.'.�
'
_ rk❑Not Observable
Applicable
-;❑Not
C402.2.7
U -factor of opaque doors
U- U`_ []Complies
See the Envelope Assemblies
[FR14]2 '..
associated with the building
E] Swinging ❑ Swinging El Does Not
table for values.
thermal envelope meets
❑ Nonswinging ❑ Nonswinging ❑Not Observable
requirements.
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1) '.:2 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3)
Project Title: Rigby Eye Care Report date: 04/11/16
Data filename: Page 9 of 20
Section
#
& Re .ID
Plumbing Rough -4) Inspection
Compll Is
Comments/Assumptions
C404.3
[PLS]'
;Temperature controls installed on
I
i service water heating systems (110 9F
❑Complies Requirement will be met.
❑Does Not
jfor dwelling units and lavatories in
;Public restrooms and 90 QF for other
❑Not Observable
;occupancies.)
[]Not Applicable
0404.2
[PL4]3,,
!Heat traps installed on non -circulating
"storage water tanks.
❑Complies Requirement will be met.
❑Does Not
[]Not Observable
❑Not Applicable
A A:4:---1
1 High Impact (Tier 1) Z Medium Impact (Tier 2) 3. Low Impact (Tier 3)
Project Title: Rigby Eye Care Report date: 04/11/16
Data filename:
Page 10 of 20
. "Ution Mechanical Rough -in
#Plans Verified
& Req.ID Inspection Value
0403.2.3 i HVAC equipment efficiency Efficient
[ME55]2. -;verified. y'-
0402.4.5. !Stair and elevator shaft vents
1 ' have motorized dampers that
[ME3]3 automatically close.
0401.4.5, Outdoor air and exhaust systems
2
have motorized dampers that
[ME58]3
automatically shut when not in
damage (due to sun, moisture,
use and meet maximum leakage '
wind, etc.).
rates. Check gravity dampers
-.. Thermally ineffective panel
where allowed.
C403.2.5.
Demand control ventilation
1
provided for spaces >500 ft2 and
[ME5911
>25 people/1000 ft2 occupant
density and served by systems
with air side economizer, auto
Requirement will be met.
modulating outside air damper
control, or design airflow >3,000
s❑Not Applicable
fan >= 7.5 hp are driven byanical
Requirement will be met.
or electrical variable
d drive, or driven by vane-
with variable speed blades,
F
Requirement will be met.
erate with motor demand k
0% design kW at 50% design-calcu
ducts and plenums R-
IME6012
insulated. Where ducts or —
plenums are installed in or under
a slab, verification may need to
occur during Foundation
Inspection.
.C403.2.8
"„ HVAC piping insulation thickness. in.
[ME61]2
—
Where piping is installed in or
under a slab, verification may
need to occur during Foundation
-;Inspection.
0403.2.8 -
HVAC piping insulation thickness. in.
[ME61]2 ;:.'
Where piping is installed in or —
under a slab, verification may
-:
'.
need to occur during Foundation
Insnprtinn
C403.2.8.
Piping Insulation exposed to
1
weather is protected from
[ME713
damage (due to sun, moisture,
❑Complies
❑Does Not
wind, etc.).
..403.2.8
'ME4113
-.. Thermally ineffective panel
❑Not Applicable
surfaces of sensible heating
—in. ❑Complies
❑Does
panels have insulation >= R-3.5.
C403.3.1.
Total cooling capacity without
a
economizers must be less than
[null]0
%varMaxKBtuPerH%.
I 1111911 nnpac[ I ver tl i.. 2. Medium
Project Title: Rigby Eye Care
Data filename:
Field Verified Com II
Value.,. P es? Comments/Assumptions
Efficiency.— ❑Complies See the Mechanical Systems list
❑Does Not for values.
❑Not Observable
❑Not Annlirahlp
uuumpues
❑Does Not
Exception: Requirement
does not apply.
❑Not Observable
❑Not Applicable
❑Complies
❑Does Not
Exception: Requirement
does not apply.
❑Not Observable
❑Not Applicable
u0omplies Requirement will be met.
❑Does Not
❑Not Observable
❑Not Applicable
complies Exception: Requirement
Does Not does not apply.
Not Observable See the Mechanical Systems list
Not Applicable for values.
R-- ❑Complies
❑Does Not
Requirement will be met.
❑Not Observable
❑Not Applicable
— in. ❑Complies
❑Does Not
Requirement will be met.
❑Not Observable
❑Not Applicable
—in. ❑Complies
❑Does
Exception: Piping within
Not
HVAC equipment.
[]Not Observable
❑Not Applicable
❑Complies
❑Does Not
Requirement will be met.
❑Not Observable
s❑Not Applicable
❑Complies
❑Does Not
Requirement will be met.
`❑Not Observable
f '❑Not Applicable
;. ;I❑Complies
' •.❑Does Not
Requirement will be met.
❑Not Observable
Report date: 04/11/16
Page 11 of 20
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Rigby Eye Care Report date: 04/11/16
Data filename:
Page 12 of 20
Section
Mechanical Rough -In
Plans Verified
Field Verified
& Re .111
' '.inspection
Value
Value
Complies?
Comments/Assumptions
C403.2.7 !Ducts and plenums sealed based
[ME10]2 ;on static pressure and location.
❑Complies
Requirement will be met.
'!❑Does Not
❑Not Observable
❑Not Applicable
C403.2.7. ;Ductwork operating ea a water
1.3 'column requires air leakage
❑Complies
Exception: Requirement
[ME111 3
testing.
❑Does Not
does not apply.
t?❑Not Observable
=❑Not Applicable
C403.2.7,' Ductwork operating >3 in. water
1.3 column requires air leakage
!❑Complies
Exception: Requirement
[MEll] 3
testing.
❑Does Not
does not apply.
-:-"i❑Not Observable
❑Not Applicable
C403.3.1,
C403.3.1.
Air economizers provided where
required, meet the requirements
: ❑Complies
Requirement will be met.
1
for design capacity, control
i❑Does Not
[ME62]1
signal, ventilation controls, high-
, ;'❑Not Observable
limit shut-off, integrated
-❑Not Applicable
economizer control, and provide
a means to relieve excess
outside air during operation.
C408.2.2.
1
Air outlets and zone terminal '
devices have means for air
,
!❑Complies Requirement will be met.
"i❑Does
[ME53]3
: balancing.
Not
❑Not Observable
:'-,❑Not Applicable
C403.2.10' HVAC fan systems at design
.1 conditions do not exceed
s r ❑Complies Requirement will be met.
[ME65]3
allowable fan system motor +"
"• ?❑Does Not
nameplate hp or fan system bhp.
See the Mechanical systems list
❑Not Observable for values.
..;.A❑Not
Applicable
C403.4,2
[ME6611
VAV fan motors >=7.5 hp to be VSD
driven by variable speed drive, ❑ Vane axial
VSD ❑Complies Exception: Requirement
❑ Vane axial ❑Does does
have a vane -axial fan with
fan
Not
fan
not apply.
variable pitch blades, or have Other
❑ Other ❑Not Observable
controls to limit fan motor
❑Not Applicable
demand.
C403.4z2
[ME66]
VAV fan motors >=7.5 hp to be VSD
driven by variable speed drive, ❑ Vane axial
VSD ❑Complies Exception: Requirement
El Vane axial❑Does does
have a vane -axial fan with
fan
N
Not
fan
notaI
apply.
variable pitch blades, or have Other
❑Other ❑Not Observable
controls to limit fan motor
❑Not Applicable
demand.
C403.4.2
[ME6611
VAV fan motors >=7.5 hp to be VSD
driven by variable speed drive, ❑ Vane axial
VSD ❑Complies Exception: Requirement
El Vane axial❑Does does
have a vane -axial fan with
fan
N
Not
fan
notaI
apply.
variable pitch blades, or have Other
E] Other (--]Not Observable
controls to limit fan motor
❑Not Applicable
demand.
C403.4.2. -
1
VAV fans have static pressure '''"
sensors positioned so setpo+
""❑Complies Requirement will be met.
Not
[ME67]2
<=1/3 total design pressure..
,>;❑Does
'
"^ " :;❑Not Observable
❑Not Applicable
C403.4.2.
2
Reset static pressure setpoint for ,
DDC controlled VAV boxes
. "❑Complies Requirement will be met.
[ME24]1.
reporting to central controller
❑Does Not
based on the zones requiring the
`:!❑Not Observable
most pressure.
!❑Not Applicable
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Rigby Eye Care Report date: 04/11/16
Data filename:
Page 12 of 20
Section Mechanical Rough -In Plans Verified Field Verified
# Inspection Value Value.: Complies? Comments/Assumptions.
& Req.ID`
0403.2.6 Exhaust air energy recovery on `❑Complies
[ME57]1 ;systems meeting Table C403.2.6 ❑Does Not
„ ❑Not Observable
C403.2.11 I Unenclosed spaces that are "'r
-'i❑Complies Exception: Requirement
[ME71]1 'heated use only radiant heat. `.❑Does Not does not apply.
'. E]Not Observable
'i ❑Not Applicable
mutatnonai Comments//assumptions:
1 JHlgh Impact (Tier 1) ,2- Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Rigby Eye Care Report date: 04/11/16
Data filename: Page 13 of 20
Sectin
#
Rough -In Electrical inspection
Complies?
Comments/Assumptions
& Reg. ID
C405.2.2..
(Automatic controls to shut off all
❑Complies
Exception: Emergency egress lighting.
1
-i building lighting installed in all
❑Does Not
[EL22]2
:;buildings.
❑Not Observable
❑Not Applicable
C405.2.1.
Independent lighting controls installed
❑Complies
Exception: Lighting that is related to means of egress in
I
per approved lighting plans and all
[--]Does Not
stairways or corridors.
[EL23]2
manual controls readily accessible and
[]Not Observable
visible to occupants.
❑Not Applicable
C405.2.1.
Lighting controls installed to uniformly
❑Complies
Exception: Areas with only one luminaire of less than 100
2
reduce the lighting load by at least
❑Does Not
watts.
[EL15]1
50%.
❑Not Observable
[]Not Applicable
C405.2.2.
Daylight zones provided with
'.
❑Complies
Exception: Enclosed daylight zones with two or fewer light
3
individual controls that control the
❑Does Not
fixtures do not require a separate switch for general area
[EL16]2
i. lights independent of general area
❑Not Observable
lighting.
lighting,
❑Not Applicable
C405.2.3 '
Sleeping units have at least one
❑Complies
Exception: Requirement does not apply.
[EL17]3 - `
master switch at the main entry door
❑Does Not
that controls wired luminaires and
switched receptacles.
❑Not Observable
[]Not Applicable
C405.2.2.
Occupancy sensors installed in
❑Complies
Exception: Automatic -on controls are allowed in corridors,
2
required spaces.
❑Does Not
stairways, restrooms, primary building entrance areas and
[EL18]1
❑Not Observable
lobbies, and areas where manual -on controls could impact
❑Not Applicable
safety or security.
0405.2.2.
Primary sidelighted areas are
❑Complies
Requirement will be met.
3
equipped with required lighting
❑Does Not
[EL20]1
controls.
❑Not Observable
[]Not Applicable
C405.2.2.
Enclosed spaces with daylight area ❑Complies
Exception: Requirement does not apply.
3
under skylights and rooftop monitors ❑Does Not
[EL21]1
are equipped with required lighting
❑Not Observable
controls.
[]Not. Applicable
C405.2.4
' Automatic lighting controls for exterior ❑Complies
Requirement will be met.
[EL25]=. -:<z,
lighting installed. El Does Not
[]Not Observable
❑Not Applicable
C405.2.3
Separate lighting control devices for ❑Complies
Requirement will be met.
[EL4]1
specific uses installed per approved E1 Does Not
lighting plans.
[]Not Observable
❑Not Applicable
C405.3 "'
Fluorescent luminaires with odd ❑Complies
Exception: Requirement does not apply.
[EL19]3
numbered lamp configurations that ❑Does Not
are with 10 feet center to center (if
❑Not Observable
recess mounted) or are within 1 foot
edge to edge (if pendant or surface ❑Not Applicable
mounted) shall be tandem wired.
C405.4
Exit signs do not exceed 5 watts per ❑Complies Requirement will be met.
[EL611
face. ❑Does Not
[-]Not Observable
❑Not Applicable
1 I High Impact (Tier 1) ,2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3)
Project Title: Rigby Eye Care Report date: 04/11/16
Data filename: Page 14 of 20
"Section
# Rough -in Electrical Inspection Complies? Comments/Assumptions.
& Re .ID
C405.6 ! Exterior grounds lighting over 100 W ❑Complies Requirement will be met.
[EL24]1 :!provides >60lm/W unless on motion
❑Does Not
sensor or fixture is exempt from scope
(--]Not Observable
;of code or from external LPD.
❑Not Applicable
C405.2.3 iAdditional interior lighting power
❑Complies Requirement will be met.
[EL8]1 allowed for special functions per the
❑Does Not
approved lighting plans and is
[]Not Observable
automatically controlled and
separated from general lighting.
[]Not Applicable
Additional Comments/Assumptions:
1 I High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 13 Low Impact (Tier 3)
Project Title: Rigby Eye Care Report date: 04/11/16
Data filename: Page 15 of 20
Section
Roof insulation installed per
manufacturer's instructions.
❑Complies Requirement will be met.
Requirement
Not
Requirement will be met.
Blown or poured loose -fill
with R -value or insulation ;t
#
& Re .ID'
insulation Inspection
Plans Verified
Value
Fie1d Verified
Value `.
Compiles?
Comments/Assumptions ,.
C402.4.1.
1
All sources of air leakage in the
!building thermal envelope are +
Requirement will be met.
other relevant data.ONot
❑Complies
Requirement
Requirement will be met.
[IN1]1
]sealed, caulked, gasketed,
❑Not Observable
❑Not Applicable
ElNot
❑Not Applicable
Y' Exterior insulation is protected
weather stripped or wrapped with
{. `� a'�,❑Complies
Exception:
Exception: Requirement
;ONotObservable
damage with a protective
'material.
:
Imoisturevapor-permeable (,
does not apply.
❑Not Applicable
z 1,f
wrapping material to minimize air:
"foundation insulation may need I'
z`
Observable
I leakage, i
to occur during Foundation -
,,;❑Not
"`r?❑Not Applicable
402.4.2.
Roof R -value. For some ceiling
R-_
R-
❑Complies
See the Envelope Assemblies
[[IN2] 1
systems, verification may need to
❑ Above deck
L] Above deck
❑Does Not
table for values.
Not
occur during Framing Inspection.
❑ Metal
❑ Metal
❑Not Observable
Attic
E] Attic
Attic
❑Not Applicable
C303.2
[IN3] 1
Roof insulation installed per
manufacturer's instructions.
❑Complies Requirement will be met.
Requirement
Not
Requirement will be met.
Blown or poured loose -fill
with R -value or insulation ;t
:w„�+t❑Does
insulation is installed only where
:❑Not Observable
the roof slope is <=3 in 12. j. ;.,
+❑Not Applicable
0303.2
[IN7]1
Above -grade wall insulation❑Complies
installed per manufacturer's
Requirement will be met.
other relevant data.ONot
instructions.
.!❑Does Not
❑Not Observable
❑Not Applicable
❑Not Applicable
C402.2.5`'Floor insulation R -value. R- R- ❑Complies See the Envelope Assemblies
[INB]z ❑ Mass ❑ Mass ❑Does Not table for values.
❑ Steel ❑ Steel ❑Not Observable
❑ Wood ❑ Wood ❑Not Applicable
C303.2 Floor insulation installed per I 4,.`,c 1111+ ..,❑Complies Requirement will be met.
[IN9]2 manufacturer's instructions. ��z-;, ;aODoes Not
❑Not Observable
+ ` {❑Not Applicable
C303.1
[IN 10]
Building envelope insulation is �r k
labeled
Complies
Requirement will be met.
with R -value or insulation ;t
:w„�+t❑Does
Not
certificate providing R -value and "
other relevant data.ONot
Observable
❑Not Applicable
0303.2.1
Y' Exterior insulation is protected
�r'
{. `� a'�,❑Complies
Exception:
Exception: Requirement
[IN14]from
damage with a protective
'material.
:
'.
does not apply.
Verification for exposed
z 1,f
"foundation insulation may need I'
z`
Observable
to occur during Foundation -
,,;❑Not
"`r?❑Not Applicable
r,
Inspection.'
1 ,,,
0402.2.1
Insulation intended to meet the
`❑Complies
Requirement will be met.
[IN17]
roof insulation requirements,;❑Does
`cannot
Not
be installed on top of a
suspended ceiling. Mark this !'"
` ❑Not Observable
requirement compliant if
��
'`❑Not Applicable
Insulation is installed accordingly.
.+. MJL,vuuK — log, ltlnC3/A95ti mption s:
1 High Impact (Tier i) -.2'` Medium Impact (Tier 2) 3.. Low Impact (Tier 3)
Project Title: Rigby Eye Care Report date: 04/11/16
Data filename: Page 16 of 20
Sections
# Final Inspection
& Re .ID
Complies?
Comments/Assumptions
C402.4.6 weatherseals installed on all loading
[F13711 'dock cargo doors.
❑Complies Exception: Requirement does not apply.
❑Does Not
�.
❑Not Observable
[]Not Applicable
C403.2'.4..Thermostatic controls have a 5 °F
2
❑Complies Requirement will be met.
[FI3813
,deadband•
❑Does Not
-
❑Not Observable
❑Not Applicable
C403.2.4.
Temperature controls have setpoint
❑Complies Requirement will be met.
2
overlap restrictions.
❑Does Not
[F120]3
❑Not Observable
❑Not Applicable
C403.2.4..'.
3
Each zone equipped with setback
❑Complies Requirement will be met.
controls using automatic time clock or ❑Does Not
[FI39]3
programmable control system.
❑Not Observable
❑Not Applicable
C403.2.4.
Automatic Controls: Setback to 55°F
❑Complies Requirement will be met.
3-. _.
(heat) and 85°F (cool); 7 -day clock, 2-
Not
❑Does Not
[F140]3
`hour occupant override, 10 -hour
backup
❑Not
❑Not Applicable
C408.2.5.
1
Furnished HVAC as -built drawings
❑Complies Requirement will be met.
- submitted within 90 days of system
❑Does Not
[F1713
'acceptance.
❑Not Observable
❑Not Applicable
C303.3,C4i Furnished O&M manuals for HVAC
❑Complies Requirement will be met.
D8.2.5.3
- systems within 90 days of system
❑Does Not
[F]8]3
acceptance.
[]Not Observable
❑Not Applicable
C408.2.5.
An air and/or hydronic system
❑Complies Requirement will be met.
3
balancing report is provided for HVAC
❑Does Not
[FI4311
systems.
❑Not Observable
❑Not Applicable
C408.2.3.
2
HVAC control systems have been
❑Complies Requirement will be met.
tested to ensure proper operation,
❑Does Not
[FI10]1
calibration and adjustment of controls.
❑Not Observable
❑Not Applicable
C404.3
[F]11]3 `:
' Public lavatory faucet water
temperature <=110°F.
❑Complies Requirement will be met.
❑Does Not
❑Not Observable
❑Not Applicable
C404.5
[F[45]2..
First 8 ft of outlet piping is insulated
❑Complies Requirement will be met.
,.
❑Does Not
❑Not Observable
❑Not Applicable
C402.4.8
[F126]3
Recessed luminaires in thermal
envelope to limit infiltration and be IC
❑Complies Requirement will be met.
[]Does Not
rated and labeled. Seal between
interior finish and luminaire housing.
❑Not Observable
❑Not Applicable
C403.2.2 -
[FI27]3 '
HVAC systems and equipment
❑Complies Requirement will be met.
:
capacity does not exceed calculated
El Does Not
loads.
❑Not Observable
❑Not Applicable
1 I High Impact (Tier 1) .2 1 Medium Impact (Tier 2) 3 1 Low Impact !T'_ vi
Project Title: Rigby Eye Care Report date: 04/11/16
Data filename:
Page 17 of 20
Section
# Final Inspection Complies?
Rea-ID Comments/Assumptions
&
C408.2.5.
I i
Furnished as -built drawings for ❑Complies Requirement will be met.
electric power systems within 30 days ❑Does Not
[FI16]3 jof
system acceptance.
;:..
[]Not Observable
❑Not Applicable
C303.3,C4 Furnished O&M instructions for
08.2,5.2. 'systems and equipment to the
❑Complies Requirement will be met.
❑Does Not
[FI17]3
building owner or designated
representative.
❑Not Observable
❑Not Applicable
C405.5.2
[FI18]1
Interior installed lamp and fixture ❑complies See the Interior Lighting fixture schedule for values.
lighting power is consistent with what ❑Does Not
is shown on the approved lighting
plans, demonstrating proposed watts
❑Not Observable
are less than or equal to allowed
❑Not Applicable
watts.
C405.6.2
[FI19]1
Exterior lighting power is consistent
with what is shown on the approved
❑Complies See the Exterior Lighting fixture schedule for values.
❑Does Not
lighting plans, demonstrating
proposed watts are less than or equal
❑Not Observable
to allowed watts.
❑Not Applicable
C408.2.1
[FI2811
Commissioning plan developed by
❑Complies Requirement will be met.
registered design professional or
[]Does Not
approved agency.
❑Not Observable
❑Not Applicable
0408.2.4
[F12911
Preliminary commissioning report
❑Complies Requirement will be met.
completed and certified by registered
❑Does Not
design professional or approved
agency.
❑Not Observable
❑Not Applicable
C408.2.5.
4
Final commissioning report due to
❑Complies Requirement will be met.
building owner within 90 days of
❑Does Not
[F13011
receipt of certificate of occupancy.
[]Not Observable
❑Not Applicable
0408.2.3.
1
HVAC equipment has been tested to
❑Complies Requirement will be met.
(FI3111
ensure proper operation.
❑Does Not
❑Not Observable
❑Not Applicable
0408.2.3.
3
Economizers have been tested to
❑Complies Requirement will be met.
[FI3211
ensure proper operation.
El Does Not
❑Not Observable
❑Not Applicable
C408.3
[FI3311
Lighting systems have been tested to
❑Complies Requirement will be met.
ensure proper calibration, adjustment,
❑Does Not
programming, and operation.
❑Not Observable
[]Not Applicable
0408.3
[F14811
Lighting systems have been tested to
ensure
❑Complies Requirement will be met.
proper calibration, adjustment,
El Does Not
programming, and operation.
[]Not Observable
❑Not Applicable
C406
[FI3411
Efficient HVAC performance, efficient
lighting system, or on-site supply of
❑Complies Requirement will be met.
❑Does Not
renewable energy consistent with
what is shown the approved plans.
❑Not Observable
❑Not Applicable
......,w• �. v,,,n lcuai/MiiY1111J1IVr15�
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Rigby Eye Care Report date: 04/11/16
Data filename:
Page 18 of 20
Project Title: Rigby Eye Care
Data filename:
Report date: 04/11/16
Page 19 of 20
Project Title: Rigby Eye Care Report date: 04/11/16
Data filename: Page 20 of 20