HomeMy WebLinkAboutINSPECTION TICKET 3-15-2017 - 16-00572 - Grace Baptist - AdditionInspection
Ticket
Commercial Building Final on 03/15/2017: FAIL
Permit Number: 16-00572Permit Details
Commercial Addition
Permit Issued Date: 12/06/2016
Final Inspections Required
Commercial Building Final
262 N 2nd W
Grace Baptist - Addition
Inspection Details
quinton.owens@rexburg.org
Inspected By: Quinton Owens
Commercial Building Final on 03/15/2017: FAIL
D ESCRIPTIO N CO MMEN TS STATUS
Occupant load is posted as required.Maximum occupant load in addition is 49.N/A
Exterior egress components (driveways,
sidewalks, ramps, etc.) completed.
Threshold on east egress door exceeds min.
height without bevel.
FAIL
Landscaping and other exterior construction
activities completed or properly separated.
Proper landing or deck with (area of refuge)
and stairs on east end planned as soon as
weather allows.
FAIL
All egress components (ramps, landings, stairs,
handrails, guardrails, etc.) meet code.
Temporary stairs are on east end until better
weather allows for deck installation.
FAIL
Inspector Comments
Fire extinguisher, class 2A-10B-C, is required.
Post sign by stove limiting appliance to warming use only.
Note: Steps will require handrail on both sides. Guardrail is required where floor is more than 30" above adjacent
elevation.
** Temporary C.O. approved until April 30, 2017 **