HomeMy WebLinkAboutREVIEW RESPONSE LETTER - 16-00576 - 117 S 2nd E - Mattson Apts - Bldg A SO 25 Units 3520 N. University Ave Suite 200, Provo, UT 84604 Phone 801.377.6303 www.harris-architecture.com Page 1 of 2 6 January 2017 . City of Rexburg Attn: Quinton Owens 35 North 1st East Rexburg, Idaho 86440 RE: MATTSON APARTMENTS SOUTH New 5-story student apartment building for Mattson / Westland Investors Rexburg, Idaho Zoning: Mixed Use 2 Construction type: 5A Sprinklered: Yes Square footage: 49,649 sf The attached drawings are submitted in response to Plan Review Comments (dated 11/28/2016) for the project indicated above. RESPONSE TO PLAN CHECK COMMENTS - #2 Comment 1: Fire resistance rating of building elements meet the req. of IBC Sect 703, 704 NOTES AND KEYNOTES ARE REVISED TO SHOW 1-HOUR FLOOR CEILING ASSEMBLY PER CONSTRUCTION TYPE 5A. ADDED AT TOWNHOUSE (2-LEVEL) UNITS, TYPICAL. • REVISED ON SHEETS A3.1, A3.2, A3.3, A3.4 Comment 2: Ducts and dampers meet the requirements of IBC Section 717 DAMPERS ON EXHAUST FANS SHOWN AND NOTED ON PLANS. • SEE REVISED MECHANICAL DRAWINGS (ATTACHED) FOR CLARIFICATION. Comment 3: Toilets, Bathing Fac., Sinks, Kitchen and Drinking Fountain meet IBC Sec. 1109 705 NOTES ADDED FOR RETRACTABLE SWINGING DOORS FOR FORWARD APPROACH AT LOWER LEVEL TOWNHOUSE LAVATORIES. • SEE TOWNHOUSE UNIT PLANS, SHEETS A1.10 – A1.16. Comment 4: Interior Space Dimensions meet the requirements of IBC Section 1208 DIMENSION REQUIREMENTS ADDED/ MODIFIED AT 2-LEVEL UNIT PRIVATE STAIRWAYS FOR MINIMUM 36” WIDTH AT WINDING STAIR. • SEE TOWNHOUSE UNIT PLANS, SHEETS A1.10 – A1.16. 3520 N. University Ave Suite 200, Provo, UT 84604 Phone 801.377.6303 www.harris-architecture.com Page 2 of 2 Comment 5: Stairways meet the requirements of IBC Section 1009 SHIPS LADDER PROVIDED FOR ROOF ACCESS PER DISCUSSION AND STANDARDS RECEIVED FROM FIRE DEPARTMENT. • SEE STAIR #2 AT UPPER FLOOR PLANS, SHEETS A1.4, A1.5 AND ROOF PLAN SHEET A5.1 Comment 6: Elevators and Conveying Systems meet the requirements of Chapter 30 EQUIPMENT ROOM CEILING EDITED FOR 2-HOUR PROTECTION. • SEE SECTION B/A3.2 • SEE REVISED MECHANICAL DRAWINGS (ATTACHED) FOR HOISTWAY VENTILATION. ADDITIONAL INSPECTOR COMMENTS - #2 Comment A: Interior bearing wall headers SEE STRUCTURAL NOTES REGARDING STRUCTURAL CONTINUITY AT DUCT (ETC.) PENETRATIONS AT BEARING WALL HEADERS. Comment B: Emergency egress windows WINDOWS MEETING REQUIREMENTS FOR EMERGENCY EGRESS ARE PROVIDED AT EACH SLEEPING ROOM. SEE WINDOW DETAILS, SHEETS A4.0, A4.1 Comment C: Mechanical closet doors CLOSER AND SEAL ADDED FOR DOORS TO MECHANICAL CLOSETS FROM BATHROOMS. SEE UNIT DOOR SCHEDULE, SHEET A4.1 Comment D: Protection for Shower valves in rated walls NOTES INDICATE REQUIREMENT TO MAINTAIN FIRE RATING AROUND SHOWER VALVES IN RATED WALLS. DETAILS ARE ALSO PROVIDED FOR VARIOUS CONDITIONS THAT MAY OCCUR. Comment: Separation at existing building SEPARATION BETWEEN AN EXISTING STRUCTURE AND THE PROPOSED BUILDING IS BETWEEN 5 – 10 FEET. PROTECTION IS PROVIDED AT THE NEW BUILDING; NOTES ARE ADDED FOR INSTALLATION OF RATED WALLS AND PROTECTED OPENINGS AT THE EXISTING BUILDING. SEE SHEET A0.1 Thank you for your continued help on with this project. We look forward to working closely with the City to successfully complete the Mattson Apartments project. Regards, Doug Spohn, LEED AP HARRIS ARCHITECTURE DOUG@HARRIS-ARC.COM