Loading...
HomeMy WebLinkAboutRESCHECK - 16-00580 - 1050 Larch - SFRCREScheck Software Version 4.6.2 �(J Compliance Certificate Project Lot 9 Block 7 Pinebrook est. Energy Code: 2012 IECC 21.0 Location: Idaho Falls, Idaho 21 Construction Type: Single-family Project Type: New Construction 1 Conditioned Floor Area: 3,854 ft2 21.0 Glazing Area 14% 1 Climate Zone: 6 (7918 HDD) Permit Date: 0.320 2 Permit Number: 518 21.0 Construction Site: Owner/Agent: Designer/Contractor: Window 1: Other:Single Pane Green Works Builders COMFORTAIR DESIGN DBA WIEMER 0.320 HEATING Wall 4: Wood Frame, 16" o.c. 27 COMFORTAIR DESIGN DBA WIEMER 0.0 0.057 HEATING Window 1: Other:Single Pane 9 IDAHO FALLS, ID 0.320 208-523-3848 Compliance: Passes using UA trade-off Compliance: 0.3% Better Than Code Maximum UA: 330 Your UA: 329 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home. Envelope Assemblies Wall 1: Wood Frame, 16" D.C. 371 21.0 0.0 0.057 21 Window 1: Other:Single Pane 4 0.320 1 Wall 2: Wood Frame, 16" D.C. 25 21.0 0.0 0.057 1 Window 1: Other:Single Pane 7 0.320 2 Wall 3: Wood Frame, 16" D.C. 518 21.0 0.0 0.057 23 Window 1: Other:Single Pane 108 0.320 34 Wall 4: Wood Frame, 16" o.c. 27 21.0 0.0 0.057 1 Window 1: Other:Single Pane 9 0.320 3 Wall 5: Wood Frame; 16" D.C. 466 21.0 0.0 0.057 26 Window 1: Other:Single Pane 10 0.320 3 Wall 6: Wood Frame, 16" D.C. 655 21.0 0.0 0.057 31 Door 1: Solid 38 0.140 5 Window 1: Other:Single Pane 71 0.320 23 Basement Wall 1: Solid Concrete or Masonry 353 19.0 0.0 0.045 16 Wall height: 9.0' Depth below grade: 7.5' Insulation depth: 9.0' Project Title: Lot 9 Block 7 Pinebrook est. Report date: 09/02/16 Data filename: C:\Users\User\AppData\Local\Check\REScheck\ Green Works Const.Lot 9 Block 7 Page 1 of 2 tsasement wan z: t)oua concrete or Masonry 556 19.0 0.0 0.045 23 Wall height: 9.0' Depth below grade: 7.5' Insulation depth: 9.0' Window 1: Other:Single Pane 40 0.320 13 Basement Wall 3: Solid Concrete or Masonry 353 19.0 0.0 0.045 16 Wall height: 9.0' Depth below grade: 7.5' Insulation depth: 9.0' Basement Wall 4: Solid Concrete or Masonry 556 19.0 0.0 0.045 24 Wall height: 9.0' Depth below grade: 7.5' Insulation depth: 9.0' Window 1: Other.Single Pane 32 0.320 10 Ceiling 1: Flat Ceiling or Scissor Truss 2,057 50.0 0.0 0.026 53 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in REScheck Version 4.6.2 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name - Title Signature Date Project Notes: job Number: Lot 9 INFORMATION CONTAINED WITHIN THE REPORT IS PER THE RESCHECK COMPLIANCE CERTIFICATE. IF ANY OF THESE VALUES SHOULD CHANGE, THIS REPORT WILL BE NULL AND VOID. Project Title: Lot 9 Block 7 Pinebrook est. Report date: 09/02/16 Data filename: C:\Users\User\AppData\Local\Check\REScheck\ Green Works Const.Lot 9 Block 7 Page 2 of 2 2012 IECC Energy Efficiency Certificate Above -Grade Wall 21.00 Below -Grade Wall 19.00 Floor 0.00 Ceiling / Roof 50.00 Ductwork (unconditioned spaces): Window 0.32 Door 0.14 Heating & Cooling Equipment Efficiency Heating System: Cooling System• Water Heater: Name: Date: Comments