Loading...
HomeMy WebLinkAboutENGINEERING CALCS - 16-00580 - 1050 Larch - SFRAugust 22, 2016 Architect/Designer: Hearthstone Design Contractor/Builder: Green Works Builders REFERENCE: Lot 9 Block 7 Pinebrook Estates Rexburg, ID Plan R -1754a-114. The calculations for this project are valid for the plan and lot(s) referenced and are subject to the following conditions: Design Criteria: IBC/IRC 2015 Roof Snow Load: 35 psf Floor Live Load: 40 psf Roof Dead Load: 18 psf Floor Dead Load: 15 psf Wind Speed and Exposure: 115 mph Exp. C Seismic Zone: Section 1613, Cat. D Soils Report: 1500 psf - assumed • Note: The lateral forces (Wind and Seismic) used in the design of this project are the minimum required by the code. These minimum forces and the resulting design provide for a measure of safety for preventing structural conditions causing failure or collapse. The design does not guarantee the structure will not sustain damage during a seismic occurrence or high wind condition. Proper construction of the following lateral resisting elements is necessary to obtain the level of safety required by code: 1. Roof and floor diaphragm construction and attachment to supporting members (shearwalls, beams, foundation). 2. Shear walls - proper nailing, blocking, and construction. 3. Foundation holdowns, anchor bolts, between level straps. All straps and holdowns must be placed as shown on plans to work in conjunction with the shearwalls to prevent uplift and transfer all lateral and uplift forces to the foundation. Soils Condition: It is the builder's responsibility to ensure the soil is suitable for construction. Any items that may affect the structural design must be brought to the attention of the Engineer of record. Revisions to Plans: Any modifications, revisions, additions, or variations to the plans and the design void the design and all responsibility and liability. All changes of any kind must be brought to the attention of the Engineer of record prior to construction. This also applies if truss layout is different than that shown on the plans. Additional Services: Any modifications, revisions, additions, or variations requiring additional review or design will be billed at a rate of $250.00 per hour (one hour minimum). Allow adequate time for review of any changes. Should there be any clarifications, questions or comments relating to the design, please feel free to contact me. Respectfully, R. Lynn Carlson, S.E. CES Carlson Engineering Services, Inc. 550 North 200 W.et, Suite 110 bountiful, Lit 54010 (801) 296-2784 Fax 18011 .296-6253 Structural Design Calculations Reference: Lot 9 Block'7 Pinebrook Estates Subdivision Green Works Builders Rexburg,ID Plan R -1754a-114 Plans by: Hearthstone Design Design Data: Code: IBC 2015, ASCE 9-10 Seismic: IBC Section 1613, ASCE 7-10, Chaper 12, Seismic Design Category D Site Soil: 1,500 psf Bearing (Assumed), Site Class D Wind: 115 mph, Exp C , (3 sec. gust) Roof Load: 35 psf (Ps) Roof Slope: 6 (in/ft) ***Note: These calculations are lot specific (i.e., valid for this plan on this lot only). These calculations must be reviewed and re -stamped to be valid if this plan is built on another lot or modified in any way. >OS N SFQC� F C 9 1665 0 roe (y N v5�� r7 Carlson Engineering Services, Inc. 38o North 200 West Bountiful, Utah 84010 (bot) 296-2784 Fax (bot) 296-6253 r1c Aug -16 Sht 1 Rev o Loading Summary Floor D.L: 15 psf Walls (Ext.) = psf Walls (Int.) = 5.5 psf Roof = 18 psf + L.L. (See below) ** Exterior Wall Types (Reference) Type (1) - Brick 45.0 psf Type (2) - Stucco 17.0 psf Type (3) - Siding 8.0 psf Type (4) - Wood 9.5 psf Type (5) - Comb. 27.0 psf Roof Snow Loads.- ASCE 7-10. Chapter 7 (Reference IBC 1608) Snow = 35 psf Slippery Surfaces (Unobstructed Sliding) L.L. 35.0 psf D.L. 15.0 psf Total 50.0 psf Elevation: 4500 ft Additional snow load in seismic: ((Elev./1000)) - 5) x 0.025 x L.L. Utah Amendment T Beam Loading (psf) Seismic Loading = 21.6 psf (20% of snow if over 40 psf + Utah amendment) ric Aug -16 Sht 2 Rev 0 Seismic Design ASCE 7-10,12.14.8.1 V= F`SDs•W Ss= 150.00 Fa= 1.00 SDs = 0.667(Fj (Ss) = 1.001 Table 11.4-1 (Site Class D) R V = 1.0 'SDs'W 0.154 (F = 1.0 for 1 -story, F = 1.1 for 2 -stories, F = 1.2 for 3 -story) 6.5 Roof (Transverse) Width x W (psf) #/ft x Lenqth w(#) Roof (1) = 38 21.6 819.375 40 32775 Roof (2) = 59 21.6 1272.19 21.5 27352 Roof (3) = 38 21.6 819.375 12 9833 Qty Ht. Length Wt. Walls Int. 2 4.0 73.5 10 5880 Total 75,840 # Tvpe Lonq Walls Qty x psf x Heiqht x Lenqth # 3 Wall (1) 2 8 8.9 40 5696 3 Wall (2) 1.2 8 5.5 21.5 1135 3 Wall (3) 1.2 8 4.5 12 518 Total 7,349 # Tvpe End Walls Qtv x psf x Heiqht x Lenqth # 3 Wall (1) 1 8 4 57 1824 3 Wall (2) 1 8 4.5 50 1800 3 Wall (3) 1 8 4.5 36 1296 Total mass tributary to roof level = 88,109 # Total 4,920 # rlc Aug -16 Sht 3 Rev 0 Upper Floor (Transverse Width x W ()sf) #/ft x Lenqth w(#) Floor (1) = N/A 0 Floor (2) = N/A Floor (3) = N/A Total 0 # Tvpe Lonq Walls Qtv x psf x Height x Lenqth # Wall (1) N/A 0 Wall (2) N/A 0 Wall (3) N/A 0 Total 0 # Tvpe End Walls Qtv x psf x Height x Lenqth # Wall (1) N/A Wall (2) N/A Wall (3) N/A Total 0 # Total mass tributary to upper level = 0 # Total Seismic Mass = 88,109 # Total Seismic Lateral Force = 13,562 # rlc Aug -16 Sht 4 Rev 0 Seismic Force Distribution (Transverse) (ft, kips) 1 Totals 1 88.11 1 1,208.581 13.56 1 V= 13.56 kips Fx = 0.0112 (wxhx) 0.005386 rlc Aug -16 Sht 5 Rev 0 Roof Diaphragm Loading (Seismic) (Transverse) Roof Section Motel) Len th I w® #/ft 10.7 Factorl Uooer An le E F G H' Basic s eedRoof 3 sec ust -15.4 -8.8 Roof 1 6.61 40.00 165.2 116 N/A 30 to 45 1.1 -8.8 0.4 0 to 5 :12.8 -6.7 8.5 -4.0: Roof 2 5.22 21.50 243.0 170 N/A -4.7 11.9 -2.6. Roof Ht B C Roof 3 1:73 12.00 1 144.3 1 101 1 N/A Wind Design (Transverse ASCE Figure 28.6-1 Vertical Pressures (osf) Basic Speed 3 secgust) Roof Horizontal n Pressures one psn Interior Zone - I Ride Hei ht An le E F G H' Basic s eedRoof 3 sec ust -15.4 -8.8 -10.7 I D A 25.0 -7.2 -9.8 -5.2 -7.8 30 to 45 1.1 -8.8 0.4 0 to 5 :12.8 -6.7 8.5 -4.0: Mean Exp. Ex 90 20.0 ..17.8 -4.7 11.9 -2.6. Roof Ht B C 25.0 16.1 2.6 11.7 2.7 -15. 1.00 1.21 20.0 -32.2 -22.4 -22.4 30 to 45 14.4 9.9 11.5 7.9 20 1.00. 1.29 15.0 26.3 -8.7 17.5 -5.0 25 1.00 1.35 20.0 29.0 -7.7 19.4 -4.2. 30 1.00 1.40 115 25.0 26.3 4.2 19.1 4.3 35 1.05 1.45 30 to 45 23.6 16.1 16.8 12.9 40 1.09 1.49 0 to 5 26.8 -13.9 17.8 -8.2 45 1.12 1.53 130 20.0 37.1 -9.8 24.7 -5.4 1 50 1 1.16 1.56 25.0 33.6 5.4 24.3 1 5.5 1 55 1 1.19 1.59 30 to 45 1 30.1 20.6 24.0 1 16.5 1 60 1 1.22 1.62 Vertical Pressures (osf) Basic Speed 3 secgust) Roof ..a" Wind If Zone I Ride Hei ht An le E F G H' 90 Oto 5 -15.4 -8.8 -10.7 -6.8 20.0 -15.4 -10.7 -10.7 -8.1 25.0 -7.2 -9.8 -5.2 -7.8 30 to 45 1.1 -8.8 0.4 -7.5 115 15.0 -25.2 -16.5 -17.5 -12.6 20.0 -25.2 -17.5 -17.5 -13.3 25.0 -11.7 -15.9 -8.5 -12.8 30 to 45 9.1 -14.3 7.9 -12.3 130 0 to 5-32.3 143 -18.4 -22.4 -14.2 20.0 -32.2 -22.4 -22.4 -17.0 25.0 1 -14.9 1 -20.4 -10.8 -16.4 30 to 45 2.3 -18.3 0.8 -15.7 ASCE?-10 28.6.3 ..a" Wind If Section I Ride Hei ht Eave Ht I Wall Ht 10% Horz 40% Eavei 3 ft 1 18.0 8.0 4.0 7.4 3.2 3.0 204 2 18.0 8.0 4.0 7.4 3.2 3.0 204 3 13.5 9.0 4.5 7.4 3.6 3.0 143 rlc Aug -16 Sht 6 Rev 0 Conterminous 48 States f" OWV-6 \ IP 2005 ASCE 7 Standard Latitude = 43.8231 Longitude = -111.7924 Spectral Response Accelerations Ss and S1 Ss and S1 = Mapped Spectral Acceleration Values Site Class B - Fa = 1.0,17v = 1.0 Data are based on a 0.01 deg grid spacing Period Sa (sec) (g) 0.2 0.468 (Ss, Site Class B) 1.0 0.162 (S1, Site Class B) O-- -7 2uIF- SOV [VIC 35N 1stE Building Safety Department Rexburg, ID 83440 City of Rexburg www.rexbvrg.org 208.359.3022 or Text: C IT Y OF REXBURG America's Family Community Office Hours: Monday -Friday 8:00am-4:00pm Single Family Residential Pre -Construction Checklist Seismic Design Category — D ✓ Ground Snow — 50 lbs. per sq. ft. ✓ Roof Snow Load — 35 lbs. per sq. ft. Wind Load — 90 MPH ✓ Frost Depth -36" aw dig Nth� The following items should be completedbe oreyou submityour building permit application. Completion ofa Budding PertnitApplication: You may print this application from our website www.rex �burg.org or pickup a copy at the City HallAnnex Building (address above). FotResidentialPermits: (the following is regtiircd to be submitted befote the Apptication can be approved) ❑ 2 sets of site plans and 2 sets of building plans (must be drawn to scale) -Plans must include foundation plan, floor joist layout, floor plan, roof layout, sectional views, front, back, and side elevations, mechanical layout, stair details and any details required to illustrate special construction. ❑ Energy Compliance Report: The State of Idaho has adopted the International. Energy Conservation Code (IECC). A Compliance Review must be completed and submitted (the rescheck software is available online at -,vww.energycodes.gov). ❑ Page 2 of the Application must include the Idaho Contractor's Registration Number or the exemption form must be completed and signed, see Page 10. ❑ Page 5 of the Application must be completed and signed by your Plumber. ❑ Page 6 of the Application must be completed and signed by your Mechanical Contractor. ❑ Page 8 of the Application must be completed and signed by your Electrician. ❑ Home owners: please complete page 6 of the application if you will be doing your own electrical work. ❑ Truss details including engineered floor joists are required. ❑ Property Line form needs to be signed by the builder or owner, see Page 4. Subdivisions: If you plan to build in a subdivision please check the Rexburg Development Code for any requirements such as, property setbacks, architecture board approval, etc. This information is available from the Planning & Zoning Department at the Annex Building located at 19 East Main. New Residential Homes: If your building permit is for a new home, you will need the parcel number (a parcel number is the county's property ident#ication which recognizes a plot of lana and a new physical address will be issued. If you do not know the parcel number and cannot find a record of it, please bring the name of the subdivision, phase, and the lot and block numbers. The correct location is vital to assure correct addressin . Remodels: If you are considering a remodel, a gM of the bid or estimate for the remodel must be submitted with the Permit Application. • 2 sets of Plans are required (may need IECC Review). • Additions are the same requirements as new construction. fi�� �� ��ih�--�' �, �'!N � Ca�a�! ����, � �� Project: R -1754a (Rexburg) Location: RB -1 Side Roof Beam [2015 International Building Code(2012 NDS)] ( 2 ) 1.76 IN x 9.5 IN x 7.0 FT 1.9E Microllam - iLevel Trus Joist Section Adequate By: 380.6% CAUTIONS Ladj = Laminations are to be fully connected to provide uniform transfer of loads to a DEFLECTIONS Cents Roof Live Load: Live Load 0.03 IN L12480 35 Dead Load 0.02 in Roof Dead Load: Total Load 0.05 IN U1661 15 Live toad Deflection Criteria: U240 Total Load Deflection Criteria: U240 REACTIONS A 12 TW = Live Load 1113 Ib 813 Ib ft Dead Load 549 Ib 399 Ib WT = Total Load 1662 Ib 1212 Ib plf Bearing Length 0.63 in 0.46 in LL = 45 psf BEAM DATA DL= Span Length 7 ft psf Unbraced Length -Top 0 ft TW = Unbraced Length -Bottom 0 ft ft Roof Pitch 0 :12 LL = Roof Duration Factor 1.15 Ib MATERIAL PROPERTIES DL= 1.9E Microllam - iLevel Trus Joist Ib Base Values Adiusted Bending Stress: Fb = 2600 psi Fb' = 3087 psi Cd=1.15 CF=1.03 WALL = Shear Stress: Fv = 285 psi Fv' = 328 psi Cd=1.15 Modulus of Elasticity: E = 1900 ksi E'= 1900 ksi Comp.-Lto Grain: Fc -1= 750 psi Fc -1'= 750 psi Controlling Moment: 2818 ft -Ib 3.5 ft from left support Created by combining all dead and live loads. Controlling Shear: 1461 Ib At a distance d from support. Created by combining all dead and live loads. Comparisons with required sections: Recd Provided Section Modulus: 10.95 in3 52.65 1n3 Area (Shear): 6.69 int 33.25 int Moment of Inertia (deflection): 36.12 in4 250.07 in4 Moment: 2818 ft -Ib 13541 ft -Ib Shear: 1461 Ib 72651b page R. Lynn Carlson CES 380 North 200 West, Suite 110 0f . ' Bountiful, Utah 84010 StruCalc Version 9.0.2.5 members 8/19/2016 11:15:03 AM -_'- Side One: Ladj = 7 ft Roof Live Load: LL = 35 psf Roof Dead Load: DL= 15 psf Tributary Width: TW = 5 ft Side Two: WT = 260 plf Roof Live Load: LL = 45 psf Roof Dead Load: DL= 15 psf Tributary Width: TW = 0 ft Point Live Load LL = 700 Ib Point Dead Load DL= 350 Ib Point Load Location @ 2 ft Wall Load: WALL = 0 olf Adjusted Beam Length: Ladj = 7 ft Beam Self Weight: BSW = 10 plf Beam Uniform Live Load: wL = 175 plf Beam Uniform Dead Load: wD_adj = 85 plf Total Uniform Load: WT = 260 plf Project: R. Lynn Carlson R -1754a (Rexburg) i page Location: RB -1 CES Roof Beam 380 North 200 West, Suite 110 d [2012 International Building Code(2012 NDS)] Bountiful Utah 84010 (2 ) 1.75 IN x 9.5 IN x 15.0 FT StruCalc Version 9.0.2.5 8/19/2016 11:13:36 AM 1,9E Microllam -. iLevel Trus Joist Section Adequate By: 91.0% Ow 'Laminations are to be fully connected to provide uniform transfer of loads to all members Live Load 0.34 1N U536 Dead Load 0.19 in Total: Load 0.52 IN U344 Deflection Criteria: U180 Live Load 1050 Ib 1050 Ib Dead Load 588 Ib 588 Ib :Total Load 1638 Ib 1638 Ib Bearing Length.. 0.62 in .0.62 in BEAM DATA ft Span Length 15 ft Unbraced Length -Top 0 ft Unbraced Length -Bottom 0 ft Roof Pitch 0 :12 Roof Duration Factor 1.15 psf MATERIAL PROPERTIES 1.9E Microllam -iLevel Trus Joist Base Values Fb = 2600 psi Cd=1.15 CF=1.03 Fv = 285 psi Cd=1.15 E= 1900 ksi Fc - 750 psi Bending Stress: Shear Stress: Modulus of Elasticity: Comp.-Lto Grain: Controlling Moment: 6142 ft -Ib 7.5 ft from left support Created by combining all dead and live loads. Controlling Shear: 1474 Ib At a distance d from support. Created by combining all dead and live loads. Roof Live Load: LL = 35 psf Adjusted Roof Dead Load: DL= 17 psf Fb' = 3087 psi Tributary Width: TW = 4 ft 130.91 in4 Side Two: Moment: 6142 ft -Ib 13541 ft -Ib Fv' = 328 psi Roof Live Load: U. = 35 psf WT= Roof Dead Load: DL= 17 psf E' = 1900 ksi Tributary Width: TW = 0 ft Fc --I-' = 750 psi Wall Load: WALL = 0 Comparisons with required sections: Read Provided Section Modulus: 23.88 in3 52.65 in3 Area (Shear): 6.75 in2 33.25 in2 Moment of Inertia (deflection): 130.91 in4 250.07 in4 Moment: 6142 ft -Ib 13541 ft -Ib Shear: 1474 lb 7265 lb SLOPEIPITCH ADJUSTED LENGTHS AND LOADS Adjusted Beam Length: Ladj = 15 ft Beam Self Weight: BSW = 10 plf Beam Uniform Live Load: wL= 140 plf Beam Uniform Dead Load: wD_adj = 78 pit Total Uniform Load: WT= 218 plf Carlson Engineering Services, Inc. 2,D- , i, 54010 1g01j 293-775. Project: R -1754a (Rexburg) Location: RB -3 Roof Beam [2012 International Building Code(2012 NDS)] (2) 1.751N x 11.876 IN x 16.2 FT 1.9E Microllam -!Level Trus Joist Section Adequate By: 270.3% page r R. Lynn Carlson CES 380 North 200 West, Suite 110 of Bountiful Utah 84010 StruCalc Version 9.0.2.5 8/19/2016 11:13:35 AM to all Live Load 0.18 IN U1109 Dead Load 0.11 in Total Load 0.28 IN U689 Live Load Deflection Criteria: U240 Total Load Deflection Criteria: L/180 Live Load 851 Ib 851 Ib Dead Load .518 Ib 518 Ib Total Load 1369 Ib 1369 Ib Bearinq Length 0.52 in 0.52 in Span Length 16.2 ft Unbraced Length -Top 0 ft Unbraced Length -Bottom 0 it Roof Pitch 0 :12 Roof Duration Factor 1.15 MATERIAL PROPERTIES Ladj = 1.9E Microllam - iLevel Trus Joist LL = Base Values Adjusted Bending Stress: Fb = 2600 psi Fb' =^ 2994 psi Cd=1.15 CF=1.00 psf Shear Stress: Fv = 285 psi Fv' = 328 psi Cd=1.15 ft Modulus of Elasticity: E = 1900 ksi E'= 1900 ksi Comp. -L to Grain: Fc -1= 750 psi Fc -1'= 750 psi Controlling Moment: 5544 ft -Ib LL = 8.1 ft from left support psf Created by combining all dead and live loads. DL = Controlling Shear: 1205 Ib psf At a distance d from support. TW = Created by combining all dead and live loads. ft Comparisons with required sections: Read ProvIded Section Modulus: 22.22 in3 82.26 in3 Area (Shear): 5.51 int 41.56 in2 Moment of Inertia (deflection): 127.6 in4 488.41 in4 Moment: 5544 ft -Ib 20525 ft -Ib Shear: 1205 lb 9081 Ib Side One: Adjusted Beam Length: Ladj = Roof Live Load: LL = 35 psf Roof Dead Load: DL= 17 psf Tributary Width: TW = 3 ft Side Two: plf Total Uniform Load: WT= Roof Live Load: LL = 35 psf Roof Dead Load: DL = 17 psf Tributary Width: TW = 0 ft Wall Load: WALL = 0 SLOPE/PITCH ADJUSTED LENGTHS AND LOADS Adjusted Beam Length: Ladj = 16.2 ft Beam Self Weight: BSW = 13 plf Beam Uniform Live Load: wL = 105 plf Beam Uniform Dead Load: wD_adj = 64 plf Total Uniform Load: WT= 169 plf Carlson Engineering Services, Inc. 20_'IG 5s�,t •,!, 84010 !BO'., 298-27�_- Fa. OC'1 29a o2oT Project: R -1754a (Rexburg) Location: RB -3 GLB Roof Beam [2012 International Building Code(2012 NDS)] 3.125 IN x 10.5 IN z 16.2 FT 24F -V4 - Visually Graded Western Species - Dry Use Section Adequate By: 131.9% Controlling Factor: Deflection MATERIAL PROPERTIES 24F -V4 - Visually Graded Western Species ]3gg:Q Provided Section Modulus: Base Values Adiusted Bending Stress: Fb = 2400 psi Controlled by 130.01 in4 Fb_cmpr = 1850 psi Fb' = 2760 psi 13207 ft -Ib Cd=1.15 -1189 lb 6666 lb Shear Stress: Fv = 265 psi Fv' = 305 psi Cd=1.15 Side One: Modulus of Elasticity: E = 1800 ksi E'= 1800 ksi Comp. -L to Grain: Fc - 650 psi Fc - -L= 650 psi Controlling Moment: 5351 ft -lb 8.1 ft from left support Created by combining all dead and live loads. Controlling Shear:.. -1189 Ib At a distance d from support. Created by combining all dead and live loads. Comparisons with required sections: ]3gg:Q Provided Section Modulus: 23.26 in3 57.42 in3 Area (Shear): 5.85 int 32.81 int Moment of Inertia (deflection): 130.01 in4 301.46 in4 Moment: 5351 ft -Ib 13207 ft -Ib Shear: -1189 lb 6666 lb Page R. Lynn Carlson CES 380 North 200 West, Suite 110 or Bountiful Utah 84010 StruCalc Version 9.0.2.5 8/19/2016 11:13:35 AM LOADING DIAGRAM re A-Ar-rs.z B ROOF LOADING Side One: Roof Live Load: LL = 35 psf '. Roof Dead Load: DL = 17 psf Tributary Width: Nil = 3 ft Side Two: Roof Live Load: LL = 35 psf Roof Dead Load: DL = 17 psf Tributary Width: TW = 0 ft Wall Load: WALL= 0 pit SLOPE/PITCH ADJUSTED LENGTHS AND LOADS Adjusted Beam Length: Ladj = 16.2 ft Beam Self Weight: BSW = 7 plf Beam Uniform Live Load: wL = 105 plf'., Beam Uniform Dead Load: wD_adj = 58 plf Total Uniform Load: WT= 163 plf Carlson Engineering Services, Inc. "i- 20- Bow U- 5F010 1eC' 298-27�� -_': 29� -6253 Project: R-1 754a (Rexburg) Location: RB -4 Roof Beam [2012 International Building Code(2012 NDS)] (2) 1.51N x 9.251N x 4.2 FT #2 - Douglas -Fir -Larch - Dry Use Section Adequate By: 90.2% G.YL Laminations are to be fully connected to Live Load 0.01 IN L13520 Dead Load 0.01 In Total Load 0.02 IN U2355 Live Load Deflection Criteria: U240 Total Load Deflection Criteria: U180 .REACTIONS A 0 Live Load 1360 Ib 1360 Ib Dead Load 673 Ib 673 Ib Total Load 2033 Ib 2033 Ib Bearing Length 1.08 in 1.08 in Span Length 4.2 It Unbraced Length -Top 0 It Unbraced Length -Bottom 0 ft Roof Pitch 0 :12 Roof Duration Factor 1.15 MATERIAL PROPERTIES #2 - Douglas -Fir -Larch Comparisons with required sections: Base Values Ad6usted Bending Stress: Fb = 900 psi Fb' = 1139 psi Area (Shear): Cd=1.15 CF=1.10 27.75 in2 Shear Stress: Fv = 180 psi Fv' = 207 psi Moment: Cd=1.15 4059 ft -Ib Modulus of Elasticity: E = 1600 ksi E'= 1600 ksi Comp. -L to Grain: Fc --L = 625 psi Fc -1' = 625 psi Controlling Moment: 2134 ft -Ib psf 2.1 ft from left support DL= 17 Created by combining all dead and live loads. Tributary Width: Controlling Shear: 1301 Ib ft At a distance d from support. WALL= 0 Created by combining all dead and live loads. Comparisons with required sections: Recd Provided Section Modulus: 22.5 in3 42.78 in3 Area (Shear): 9.43 int 27.75 in2 Moment of Inertia (deflection): 15.13 in4 197.86 in4 Moment: 2134 ft -Ib 4059 ft -Ib Shear: 1301 Ib 38301b page - R. Lynn Carlson CES 380 North 200 West, Suite 110 StruCalc Version 9.0.2.5 8/19/2016 11:13:36 AM Side One: AND LOADS Adjusted Beam Length: Roof Live Load: LL = 35 psf Roof Dead Load: DL= 17 psf Tributary Width: TW = 17 ft Side Two: 321 plf Total Uniform Load: Roof Live Load: LL = 35 psf Roof Dead Load: DL= 17 psf Tributary Width: TW = 1.5 ft Wall Load: WALL= 0 SLOPEIPITCH ADJUSTED LENGTHS AND LOADS Adjusted Beam Length: Ladj= 4.2 ft Beam Self Weight: BSW = 6 plf Beam Uniform Live Load: wL = 648 plf Beam Uniform Dead Load: wD_adj = 321 plf Total Uniform Load: WT= 968 plf Carlson Engineering Services, Inc. 71'-t 2 Mfr_ -s 'IO Bent % UT 54010. !8011 293-27,5— =3x Project: R-1754a(Rexburg) Location: RB -5 Roof Beam [2012 International Building Code(2012 NDS)] (2) 1.751N x 9.51N x 6.2 FT 1.9E Microllam - iLevel Trus Joist Section Adequate By: 144.1% page R. Lynn Carlson rd w CES � 380 North 200 West, Suite 110 o� Live toad 0.05 1N U1381 Dead Load 0.03 in Total Load 0.08 1N L/921 Live Load Deflection Criteria: L/240 Total Load Deflection Criteria: L/180 Live Load 2387 Ib 2387 Ib Dead Load 1192 Ib 1192 Ib Total load 3579 Ib 3579 Ib Bearino Lenath 1.36 in 1.36 in Span Length 6.2 ft Unbraced Length -Top 0 ft Unbraced Length -Bottom 0 ft Roof Pilch 0 :12 Roof Duration Factor 1.15 MATERIAL PROPERTIES 1.9E Microllam - !Level Trus Joist Comparisons with required sections: Base Values Adiusted Bending Stress: Fb = 2600 psi Fb' = 3087 psi Area (Shear): Cd=1.15 CF=1.03 33.25 int Shear Stress: Fv = 285 psi Fv' = 328 psi Moment: Cd=1.15 13541 ft -Ib Modulus of Elasticity: E = 1900 ksi E'= 1900 ksi Comp.-Lto Grain: Fc -1= 750 psi Fc -1'= 750 psi Controlling Moment: 5547 ft -Ib psf 3.1 ft from left support DL = 17 Created by combining all dead and live loads. TributaryWidth: Controlling Shear: -2720 lb ft At a distance d from support. WALL = 0 Created by combining all dead and live loads. Comparisons with required sections: Read Provided Section Modulus: 21.57 in3 52.65 in3 Area (Shear): 12.45 in2 33.25 int Moment of Inertia (deflection): 48.86 in4 250.07 in4 Moment: 5547 ft -Ib 13541 ft -Ib Shear: -2720 lb 7265 lb StruCalc Version 9.0.2.5 8/19/2016 11:13:37 AM Side One: LENGTHS AND LOADS Roof Live Load: LL = 35 psf . Roof Dead Load: DL= 17 psf Tributary Width: TW = 17 ft Side Two: 770 pit Roof Live Load: LL = 35 psf Roof Dead Load: DL = 17 psf TributaryWidth: TW = 5 ft Wall Load: WALL = 0 SLOPE/PITCH ADJUSTED LENGTHS AND LOADS Adjusted Beam Length: Ladj = 6.2 ft Beam Self Weight: BSW = 10 plf Beam Uniform Live Load: wL = 770 pit Beam Uniform Dead Load: wD_adj = 384 plf Total Uniform Load: WT= 1154 plf Carlson Engineering Services, Inc. �_r nls - t, 20C t, t, -.'10 6o1 -t `u, Lr 8c✓'0 rR011 298-27x4 ..°a Project: R -1754a (Rexburg) Location: RB -6 Roof Beam [2012 International Building Code(2012 NDS)] (2) 1.751N x9.51N x 10.0 FT 1.9E Microllam •iLevel Trus Joist Section Adequate. By: 37.1% Laminations are to be fully connected to provide uniform transfer of loads to DEFLECTIONS Center Live Load 0.25 IN LJ483 Dead Load 0.13 in Total Load 0.37 IN L/321 Live Load Deflection Criteria:, 0240 Total Load Deflection Criteria: U180 RCAt IIVNO H_ Unbraced Length -Top 6 Unbraced Length -Bottom Live Load 2625 Ib 2625 Ib .Dead Load 1327 Ib 1327 Ib Total Load 3952 Ib 3952 Ib Bearing Lenath 1.51 in 1.51 in Span Length 10 ft Unbraced Length -Top 0 ft Unbraced Length -Bottom 0 ft Roof Pitch 0 :12 Roof Duration Factor 1.15 Moment of Inertia (deflection): MATERIAL PROPERTIES 250.07 in4 1.9E Microllam - Level Trus Joist 13541 ft -Ib Base Values Bending Stress: Fb= 2600 psi Total Uniform Load: Cd=1.15 CF=1.03 Shear Stress: Fv = 285 psi 35 Cd=1.15 Modulus of Elasticity: E = 1900 ksi Comp.-Lto Grain: Fc -1= 750 psi Controlling Moment: 9880 ft -Ib 5.0 ft from left support Created by combining all dead and live loads. Controlling Shear: -3399 lb At a distance d from support. Created by combining all dead and live loads. Ad'uste Fb' = 3087 psi Fv' = 328 psi E'= 1900 ksi Fc -1'= 750 psi Comparisons with required sections: Reo'd Provided Section Modulus: 38.41 in3 52.65 in3 Area (Shear): 15.55 in2 33.25 in2 Moment of Inertia (deflection): 140.38 in4 250.07 in4 Moment: 9880 ft -Ib 13541 ft -Ib Shear: -3399 lb 7265 lb page GB .Lynn Carlson.CES 380 North 200 West, Suite 110 Bountiful Utah .84010 SlruCalc Version 9.0.2.5 8/19/2016 11:13:37 AM Side One: AND LOADS Adjusted Beam Length: Ladj = Roof Live Load: LL = 35 psf Roof Dead Load: DL= 17 psf Tributary Width: TW = 10 ft Side Two: pit Total Uniform Load: wT= Roof Live Load: LL = 35 psf Roof Dead Load: DL= 17 psf Tributary Width: TW = 5 ft Wall Load: WALL = 0 SLOPE/PITCH ADJUSTED LENGTHS AND LOADS Adjusted Beam Length: Ladj = 10 If Beam Self Weight: BSW = 10 pif Beam Uniform Live Load: wL = 525 pit Beam Uniform Dead Load: wD_adj = 265 pit Total Uniform Load: wT= 790 plf Project: R -1754a (Rexburg) Location: RB -7 Multi -Loaded Multi -Span Beam 12012 International Building Code(2012 NDS)] (2) 1.751N x 11.875 IN x 9.2 FT 1.9E Microllam iLevel Trus Joist Section Adequate By: 42.6% Controllina Factor: Moment page =200West, 10 of StruCalc Version 9.0.2.5 8/19/2016 11:13:33 AM Laminations are to be fully connected to provide uniform transfer of loads to all members I Live Load 0.12 IN U931 Dead Load 0.06 in Total Load 0.18 INU611 Live Load Deflection Criteria: U360 Total Load Deflection Criteria: U240 Live Load 3293 Ib 2097 Ib Dead Load 1709 Ib 1133 Ib Total Load 5002 Ib 3230 Ib Bearing Length 1.91 in 1.23 in BEAM DATA Center Span Length 9.2 It Unoraced Length -Top 0 ft Unbraced Length -Bottom 9.2 It Live Load Duration Factor 1.00 Nntdh Denth 0.00 1.9E Microllam- iLevel Trus Joist Recd Provided Base Values Bending Stress: Flo = 2600 psi 21.55 in2 Cd=1.00 CF --1.00 Shear Stress: Fv = 285 psi 12517 ft -Ib Cd=1.00 Shear: Modulus of Elasticity: E = 1900 ksi Comp. J-toGrain: Fc -1= 750 psi Adjusted Fb' = 2604 psi Fv' = 285 psi E' = 1900 ksi Fc -1'= 750 psi Controlling Moment: 12517 ft -Ib 3.96 Fl from left support of span 2 (Center Span) Created by combining all dead loads and live loads on span(s) 2 Controlling Shear: 4095 Ib At a distance d from left support of span 2 (Center Span) Created by combining all dead loads and live loads on span(s) 2 Comparisons with. required sections: Recd Provided Section Modulus: 57.69 in3 82.26 in3 Area (Shear): 21.55 in2 41.56 in2 Moment of Inertia (deflection): 191.78 in4 488.41 in4 Moment: 12517 ft -Ib 17848 ft -Ib Shear: 4096 lb 7897 lb 1 JV V Uniform Live Load 0 Of Uniform Dead Load 0 plf Beam Self Weight 13 pif Total Uniform Load 13 Of Load Number One Live Load 2600 Ib Dead Load 1300 Ib Location 4 It Load Number One Two Left Live Load 650 plf 200 plf Left Dead Load 323 pif 108 pif Right Live Load 650 plf 200 pif Right Dead Load 323 plf 108 plf Load Start 0 ft 5 It Load End 3 It 9.2 It Load Length 3 It 4.2 it Carlson Engineering Services, Inc. 5_ �_ 112 . 50�r,.. . '�T b�'.OIO (BG 298-27.4 Paz X01' 1 2 6 253 Project: R-1 754a (Rexburg) Location. FB -1 Uniformly Loaded Floor Beam [2012 International Building Code(2012 NDS)] (2) 1.51N x 7.251N x 3.2 FT #2 - Douglas -Fir -Larch - Dry Use Section Adequate By: 90.0% Controlling Factor: Moment page R. Lynn Carlson CES 380 North 200 West, Suite 110 m Bountiful Utah 84010 StruCalc Version 9.0.2.5 8/19/2016 11:13:38 AM CAUTIONS *. Laminations are to be fully connected to provide uniform transfer of loads to all members 1 Wan Loaa DEFLECTIONS Center LOADING DIAGRAM Live toad 0.01 IN L/3525 Base Values Dead Load 0.00 in Fb = 900 psi Total Load 0.02 IN 02551 Cd=1.00 CF=1.20 Live Load Deflection Criteria: L/360 Total Load Deflection Criteria: U240 Fv = 180 psi REACTIONS A 4. Live Load. ` 1126. Ib 1126 Ib Modulus of Elasticity: !bead Load 430 lb 430 Ib Comp. - to Grain: Total Load 1556 Ib 1556 Ib Controlling Moment: Bearing Length 0.83 in 0.83 in 1.6 ft from left support Beam Total Dead Load: BEAM DATA - Center - Span Length 3.2 It At a distance It from support. Unbraced Length -Top 0 ft - 3.2 It 13 Floor Duration Factor 1.00 pit Notch. Depth 0.00 Total Maximum Load: MATERIAL PROPERTIES 1 Wan Loaa #2 - Douglas -Fir -Larch Section Modulus: u pit Base Values Bending Stress: Fb = 900 psi 21.75 in2 Cd=1.00 CF=1.20 Shear Stress: Fv = 180 psi Moment: Cd=1.00 Modulus of Elasticity: E = 1600 ksi Comp. - to Grain: Fc -1= 625 psi Controlling Moment: 1245 ft -Ib 1.6 ft from left support Beam Total Dead Load: Created by combining all dead and live loads. Controlling Shear: 996 lb At a distance It from support. Beam Self Weight: Created by combining all dead and live loads. FLOOR LOADING Side 1 Side 2 Ad usted Floor Live Load I'LL = 40 psf 40 psf Fb' = 1080 psi Floor Dead Load FDL = 15 psf 15 psf Floor Tributary Width FTW = 17.6 It 0 ft Fv' = 180 psi Comparisons with required sections: 1 Wan Loaa VVALL = Section Modulus: u pit E' = 1600 ksi Area (Shear): 8.3 in2 21.75 in2 Moment of Inertia (deflection): Fc --L' = 625 psi BEAM LOADING Moment: 1245 ft -1b 2365 ft -Ib Shear: Beam Total Live Load: wL = 704 plf Beam Total Dead Load: wD = 264 plf Beam Self Weight: BSW = 5 pit Total Maximum Load: wT = 973 plf Comparisons with required sections: Read Provided Section Modulus: 13.83 in3 26.28 in3 Area (Shear): 8.3 in2 21.75 in2 Moment of Inertia (deflection): 9.73 in4 95.27 in4 Moment: 1245 ft -1b 2365 ft -Ib Shear: 99616 2610 lb Project R 1754a (Rexburg) Location FB -2 Uniformly Loaded Floor Beam [2012 International Building Code(2012 NDS)] ( 2 ) 1,75 IN x 9.5 IN x 8.5 FT 1.9E Microllam -iLevel Trus Joist Section Adequate By. 54.0% O I ORAL DPT page 0 R. Lynn Carlson / CES 380 North 200 West, Suite 110 of Bountiful Utah 84010 StruCalc Version 9.0.2.5 8/19/2016 11:13:38 AM '- Laminations are to be fully connected to provide uniform transfer of loads to all members. Live Load: 0.15 IN U679 Dead Load 0.06 in Total Load 0.21 IN U488 Live Load Deflection Criteria: U360 Total Load Deflection Criteria: U240 Live Load 2584 Ib 2584 Ib Dead Load 1013 to 1013 Ib Total Load 3597 to 3597 Ib Bearina Lenath 1.37 in 1.37 in Span Length 8.5 ft Unbraced Length -Top 0 It Floor Duration Factor 1.00 MATERIAL PROPERTIES Reo'd Provided 1.9E Microllam -iLevel Trus Joist 34.18 in3 52.65 in3 Base Values Adiusted Bending Stress: Fb = 2600 psi Fb' = 2684 psi 250.07 in4 Cd=1.00 CF=1.03 7644 ft -Ib Shear Stress: Fv = 285 psi Fv' = 285 psi 6318 Ib Cd=1.00 ft Modulus of Elasticity: E = 1900 ksi E'= 1900 ksi Comp. -L to Grain: Fc -1= 750 psi Fc -L'= 750 psi Controlling Moment: 7644 ft -Ib BEAM LOADING 4.25 ft from left support Created by combining all dead and live loads. Controlling Shear: 2950 Ib 608 At a distance dfrom support. Created by combining all dead and live loads. wD = Comparisons with required sections: Reo'd Provided Section Modulus: 34.18 in3 52.65 in3 Area (Shear): 15.52 in2 33.25 in2 Moment of Inertia (deflection): 132.63 in4 250.07 in4 Moment: 7644 ft -Ib 11775 ft -Ib Shear: 29501b 6318 Ib Side 1 Side Floor Live Load FLL = 40 psf 40 psf Floor Dead Load FDL = 15 psf 15 psf Floor Tributary Width FTW = 15.2 ft 0 It Wall Load WALL= 0 plf BEAM LOADING Beam Total Live Load: wL = 608 pif Beam Total Dead Load: wD = 228 pif Beam Self Weight: BSW = 10 pif Total Maximum Load: wT= 846 pif Project: R-1 754a (Rexburg) Location: FB -3 Combination Roof And Floor Beam [2012 International Building Code(2012 NDS)] (2) 1.51N x 7.251N x 3.2 FT #2 , Douglas -Fir -Larch - Dry Use Section Adequate By: 157.4% page R. Lynn Carlson / .CES 380 North 200 West, Suite 110 or Bountiful Utah 84010 StruCalc Version 9.0.2.5 8/19/2016 11:13:39 AM Laminations are to be fully connected to provide uniform transfer of loads to all DEFLECTIONS Center Live Load 0.01 1N U4638 Dead toad 0.00 in Total Load 0.01 IN L/3005 Live Load Deflection Criteria: U360 Total Load Deflection Criteria: L/240 Live Load 856 Ib 856 Ib Dead Load 465 Ib 465 Ib Total Load 1321 Ib 1321 Ib Bearino Lenath 0.70 in 0.70 in Span Length 3.2 ft Unbraced Length -Top 0 ft Roof Pitch 0 :12 Floor Duration Factor 1.00 Roof Duration Factor 1.15 Notch Depth 0.00 MATERIAL PROPERTIES #2 - Douglas -Fir -Larch Roof Uniform Live Load: Base Values Adjusted Bending Stress: Fb = 900 psi Fb' = 1242 psi 35 psf Cd=1.15 CF=1.20 Roof Dead Load Shear Stress: Fv= 180 psi Fv'= 207 psi Roof Tributary Width Cd=1.15 13 ft Modulus of Elasticity: E = 1600 ksi E'= 1600 ksi Comp. -1- to Grain: Fc --L= 625 psi Fc -1'= 625 psi Controlling Moment: 1057 ft -Ib alk_2 1.6 ft from left support I'LL = 40 psf Created by combining all dead and live loads. Floor Dead Load Controlling Shear: 846 Ib 15 psf At a distance d from support. FTW = 2 ft Created by combining all dead and live loads. Wall Load Comparisons with required sections: Read Provided Section Modulus: 10.21 in3 26.28 in3 Area (Shear): 6.13 int 21.75 int Moment of Inertia (deflection): 7.61 in4 95.27 in4 Moment: 1057 ft -Ib 2720 ft -Ib Shear: 846 lb 3002 lb Roof Uniform Live Load: wL-roof = Side 7 Side 2 Roof Live Load RLL = 35 psf 35 psf Roof Dead Load RDL = 17 psf 17 psf Roof Tributary Width RTW = 13 ft 0 ft FLOOR LOADING BSW = 5 plf Combined Uniform Live Load: wL = Side 1 alk_2 Floor Live Load I'LL = 40 psf 40 psf Floor Dead Load FDL = 15 psf 15 psf Floor Tributary Width FTW = 2 ft 0 ft Wall Load WALL = 35 plf Roof Uniform Live Load: wL-roof = 455 pif Roof Uniform Dead Load: wD-roof = 221 plf Floor Uniform Live Load: wL-floor= 80 pif Floor Uniform Dead Load: wD-floor= 30 plf Beam Self Weight: BSW = 5 plf Combined Uniform Live Load: wL = 535 pif Combined Uniform Dead Load: wD = 291 plf Combined Uniform Total Load: WT= 826 plf Controllinq Total Desiqn Load: wT-cont = 826 plf Project: R -1754a (Rexburg) Location: FB -4 Uniformly Loaded Floor Beam (2015 International Building Code(2012 NDS)] (2) 1.751N x 9.51N x 3.5 FT 1.9E Microllam - !Level Trus Joist Section Adequate By: 27.3% ', Laminations are to be fully connected to provide uniform transfer o DEFLECTIONS Cents Live load 0.01 IN U3062 Dead Load 0.01 in Total Load 0.02 IN U2093 Live Load Deflection Criteria: U360 Total Load Deflection Criteria: Live Load 3767 Ib 2053 Ib Dead Load 1752 Ib 917 Ib Total Load 5519 Ib 2970 Ib Bearing Length 2.10 in 1.13 in Span Length 3.5 ft Unbraced Length -Top 0 ft Floor Duration Factor 1.00 Notch Depth. 0.00 WALL= MATERIAL PROPERTIES 0 plf 1.9E Microllam - !Level Trus Joist Floor Live Load Base Values Adjusted Bending Stress: Fb = 2600 psi FU = 2684 psi Cd=1.00 CF=1.03 Floor Dead Load Shear Stress: Fv = 285 psi Fv' = 285 psi Cd=1.00 15 Modulus of Elasticity: E = 1900 ksi E'= 1900 ksi Comp.-Lto Grain: Fc -1= 750 psi Fc -1'= 750 psi Controlling Moment: 5139 ft -Ib 0 1.75 ft from left support Point Live Load Created by combining all dead and live loads. 4000 Controlling Shear: 4961 Ib At a distance d from support. Point Dead Load Created by combining all dead and live loads. 1950 Comparisons with required sections: Read Provided Section Modulus: 22.98 jn3 52.65 1n3 Area (Shear): 26.11 in2 33.25 in2 Moment of Inertia (deflection): 29.4 in4 250.07 in4 Moment: 5139 ft -Ib 11775 ft -Ib Shear: 4961 Ib 63181b page C�\ R Lynn Carlson / i/� CES 380 North 200 West, Suite 110 or Bountiful, Utah 84010 StruCalc Version 9.0.2.5 8/19/2016 11:21:46 AM Wall Load WALL= Side 1 0 plf Si e 2 Floor Live Load FILL = 40 psf Beam Total Live Load: 40 psf Floor Dead Load FDL = 15 psf 195 15 psf Floor Tributary Width FTW = 13 ft Total Maximum Load: 0 It Point Live Load LL = 4000 Ib Point Dead Load DL = 1950 Ib Point Load Location @ 1 ft Wall Load WALL= 0 plf BEAM LOADING Beam Total Live Load: wL = 520 plf Beam Total Dead Load: wD = 195 plf Beam Self Weight: BSW = 10 plf Total Maximum Load: wT = 725 plf Project: R -1754a (Rexburg) Page 1 /� R. Lynn Carlson / Location: Standard Footings (\ .CES Footing 1 380 North 200 West, Suite 110 nr [2012 International Building Code(2012 NDS)] - Bountiful Utah 84010 Footing Size: 20.0 IN Wide x 10.0 IN Deep Continuous Footing With 8.0 IN Thick SlruCalc Version 9.0.2.5 8/19/2016 11:13:39 AM x 96.0 IN Tall Stemwall LongitudinalReinforcemenC (3) Continuous #4 Bars TransverseReinforcement: #4 Bars @ 9.00 IN. O.C. (unnecessary) Section Footing Design Adequate FOOTING CALCULATIONS Bearing Calculations Ultimate Bearing Pressure: Qu = 1180 psf Effective Allowable Soil Bearing Pressure: Qe = 1375 psf Width Required: Wreq = 1.43 int Beam Shear Calculations (One Way Shear): Mn = 0 in -Ib Beam Shear: Vut = 0 Ib Allowable Beam Shear: Vc1 = 6162 Ib Transverse Direction: Bending Calculations: PL= 690 Ib Factored Moment: Mu = 2372 in -Ib Nominal Moment Strength: Mn = 0 in -Ib Reinforcement Calculations: Pu = 2635 Ib Concrete Compressive Block Depth: a = 0.49 in Steel Required Based on Moment: As(1) = 0.01 in2 Min. Code Req'd Reinf. Flex. Members (ACI-10.5.1):As(2) = 0.25 in2 Controlling Reinforcing Steel: As-reqd = 0.25 in2 Selected Reinforcement: Trans: #4's @ 9.0 in. o.c. Reinforcement Area Provided: As = 0.25 in2 Development Length Calculations: Development Length Required: Ld = 15 in Development Length Supplied: - Ld-sup = 3 in Longitudinal Direction: Reinforcement Calculations: Min. Code Req'd Reinf. Flex. Members (ACI -10.5.1): As(2) = 0.42 in2 Controlling Reinforcing Steel: As-reqd = 0.42 in2 Selected Reinforcement: Longitudinal: (3) Cont. #4 Bars memroicenient rvea nuvwau. a in T 3 I T FOOTING LOADING Live Load: PL= 690 Ib Dead Load: PD = 476 Ib Total Load: PT = 1966 Ib Ultimate Factored Load: Pu = 2635 Ib Project: R-1 754a (Rexburg) Location: Girder Truss Support Column [2012 International Building Code(2012 NDS)] (S) 1.6 IN x 3.5 IN z 9.0 FT #2 - Douglas -Fir -Larch - Dry Use Section Adequate By: 45.9% P R. Lynn Carlson CES 380 North 200 West, Suite 110 Bountiful Utah 84010 StruCalc Version 9.0.2.5 8/19/2016 11:13:34 AM CAUTIONS ,' Laminations to be nailed together per National Design Specifications for Wood Construction Section 15.3.3.1 Live Load: Vert-LL-Rxn = 4620 Ib Dead Load: Vert-DL-Rxn= 2341 Ib Total Load: :Vert-TL•Rxn = 6961 Ib Total Column Length: 9 It Unbraced Length (X-A)ds) Lx: 4.5 It Unbraced Length (Y -Axis) Ly: 4.5 ft Column End Condtion-K (e): 1 Axial Load Duration Factor 1.00 COLUMN PROPERTIES #2 - Douglas -Fir -Larch Column Calculations (Controlling Case Only): Controlling Load Case: Axial Total Load Only (L + D) Actual Compressive Stress: Base Values Adiusted 442 Compressive Stress: " Fc = 1350 psi Fc'_ 817 psi Fc' = 817 Cd=1.00 Cf" -1.15 Cp=0.53 Eccentricity Moment (X -X Axis): Bending Stress (X -X Axis): Fbx = 900 psi Fbx' = 1553 psi ft -Ib Eccentricity Moment (Y -Y Axis): Cd=1.00 CF=1.50 Cr -1.15 0 Bending Stress (Y -Y Axis): Fby = 900 psi Fby' = 1553 psi Mx= 0 Cd=1.00 CF=1.50 Cr -1.15 Moment Due to Lateral Loads (Y -Y Axis): Modulus of Elasticity: E = 1600 ksi E'= 1600 ksi ft -Ib Column Section(X-X Axis): dx= 3.5 in Column Section(Y-Y Axis): dy= 4.5 in Area: A= 15.75 m2 Section Modulus(X-X Axis): Sx= 9.19 in3 Section Modulus(Y-Y Axis): Sy= 3.94 in3 Slenderness Ratio: Lexfdx = 15.43 CSF = 0.54 Ley/dy = 12 Column Calculations (Controlling Case Only): Controlling Load Case: Axial Total Load Only (L + D) Actual Compressive Stress: Fc = 442 psi Allowable Compressive Stress: Fc' = 817 psi Eccentricity Moment (X -X Axis): Mx -ex = 0 ft -Ib Eccentricity Moment (Y -Y Axis): My-ey = 0 ft -Ib Moment Due to Lateral Loads (X -X Axis): Mx= 0 ft -Ib Moment Due to Lateral Loads (Y -Y Axis): MY= 0 ft -Ib Bending Stress Lateral Loads Only (X -X Axis): Fbx = 0 psi Allowable Bending Stress (X -X Axis): Fbx' = 1553 psi Bending Stress Lateral Loads Only (Y -Y Axis): Fby = 0 psi Allowable Bending Stress (Y -Y Axis): Fby' _ 1553 psi Combined Stress Factor: CSF = 0.54 Q Live Load: PL = 4620 to Dead Load: PD= 23101b Column Self Weight: CSW = 31 Ib Total Load: PT = 6961 Ib fr 4,e5- _. �e lis . f'i OJT ,, . LT 8 010 (?YO 290-27 4 Fay :', 28a C2F3