HomeMy WebLinkAboutRESCHECK - 16-00644 - 1121 Adams Ct - SFR1ZRE check Software Version 4.6.2 Compliance Certificate Project FS2B5 - SAVANNAH Energy Code: 2012 IECC Location: Rexburg, Idaho Construction Type: Single-family Project Type: New Construction Orientation: Bldg. faces 270 deg. from North Conditioned Floor Area: 3,639 ft2 Glazing Area 15% Climate Zone: 6 (8693 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: 1121 ADAMS Cr. REXBURG, ID, 83440 Designer/Contractor: 601 w. 1700 s Logan, UT 84321 john@kartchnerhomes.com Compliance: 0.3% Better Than Code Maximum UA: 362 Your UA: 361 The % Better or Worse Than Code Index reflects haw close to compliance the house Is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home.. Envelope Assemblies Ceiling 1: Flat Ceiling or Scissor Truss Second Wall Front: Wood Frame, 16" D.C. Orientation: Front Window 1: Vinyl/Fiberglass Frame:Double Pane with Low -E Orientation: Front Second Wall Right: Wood Frame, 16" D.C. Orientation: Right side Window 7: Vinyl/Fiberglass Frame:Double Pane with Low -E Orientation: Right side Second Wall Rear: Wood Frame, 16" D.C. Orientation: Back Window 2: Vinyl/Fiberglass Frame:Double Pane with Low -E Orientation: Back Second Wall Left: Wood Frame, 16" D.C. Orientation: Left side Second floor over garage: All -Wood Joist/rruss:Over Unconditioned Space Main Wall Front: Wood Frame, 16" D.C. Orientation: Front Window 4: Vinyl/Fiberglass Frame:Double Pane with Low -E Orientation: Front Door 1: Solid Orientation: Front 1,527 344 87 304 24 312 76 304 383 480 30 53 50.0. 0.0 22.0 0.0 22.0 0.0 22.0 0.0 22.0 0.0 30.0 0.0 22.0 0.0 0.056 14 0.330 29 0.056 16 0.330 8 0.056 13 0.330 25 0.056 17 0.033 13 0.056 22 0.330 10 0.170 9 Project Title: FS2B5 - SAVANNAH Report dater 09/12/16 Data filename: C:\Users\jhoellein\Documents\REScheck\FS2B5.rck Page 1 of 9 Main Wall Right: Wood Frame, 16" o.c. 342 22.0. 0.0 0.056 19 Orientation: Right side Main Wall Rear: Wood Frame, 16" o.c. 366 22.0 0.0 0.056 13'. .Orientation: Back Window 5: Vinyl/Fiberglass Frame:Double Pane with Low -E 132 0.330 44 Orientation: Back Main Wall Left: Wood Frame, 16" o.c.. 213 22.0 0.0 0.056 12 Orientation: Left side Floor 2:. All -Wood joist/Truss:Over Outside Air 20 30.0 0.0 0.033 1 Basement Wall Front: Solid Concrete or Masonry 427 0.0 19.0 0.036 15 Orientation: Front Wall height: 8.0' Depth below grade: 8.0' Insulation depth: 8.0' Basement Wall Right: Solid Concrete or Masonry 304 0.0 19.0 0.036 11 Orientation: Right side Wall height: 8.0' Depth below grade: 8.0' Insulation depth: 8.0' Basement Wall Rear: Solid Concrete or Masonry 312 0.0 19.0 0.036 10 Orientation: Back Wall height: 8.0' Depth below grade: 8.0' Insulation depth:. 8.0' Window 8: Vinyl/Fiberglass Frame:Double Pane with Low -E 40 0.330 13 Orientation: Back Basement Wall Left: Solid Concrete or Masonry 189 0.0 19.0. 0.036 7 Orientation: Left side Wall height: 8.0' Depth below grade: 8.0' Insulation depth: 8.0' Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in REScheck Version 4.6.2 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Date Project Notes: "SAVANNAH" Founder Square Subd. Block: 5, Lot: 2,. Project Title: FS265 -SAVANNAH Report date: 09/12/16 Data filename: C:\Users\jhoellein\Documents\REScheck\FS2B5.rck Page 2 of 9 REScheck Software Version 4.6.2 Inspection Checklist Energy Code: 2012 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Pre-Inspection/Plan Review tans Verified , Fleld Verlfled '. ' ;'Value.:.'. 7 Complies? Comments/Assumptions Req.ID.:.� -Value 103.1. !Construction drawings and �, ❑Complies 103.2 documentation demonstrate i a❑Does Not [PRI]1 ;energy code compliance for the ,, ,'„.* 'I ❑Not Observable; u ;building envelope. ❑Not Applicable 103 1, ,Construction drawings and tea. k�i Ai i x asr x r,. ❑Complies 'f" ❑Does 103.2, ;documentation demonstrate r " ,`��' Not 403.7 : energy code compliance for { Observable [PR3]1 !lighting and mechanical systems '�1x.r; ❑Not Systems serving multiple "+f ,` °- ❑Not Applicable dwelling units must demonstrate'/ I compliance with the IECC Commercial Provisions. 342.1, Heating and cooling equipment is; Heating: Heating:❑Complies 403.6 J sized per ACCA Manual 5 based Btu/hr _ Btu/hr❑Does Not [PR2]2 '.. ;; on loads calculated per ACCA Cooling: Cooling: Observable V Manual J or other methods approved by the code official. I Btu/hr Btu/hr ;❑Not Applicable Additional Comments/Assumptions: 1 I High Impact (Tier 1) 12, 1 Medium Impact (Tier 2) 13, 1 Low Impact (Tier 3) Project Title: FS285 - SAVANNAH Report date: 09/12/16 Data filename: C:\Users\jhoellein\Documents\REScheck\FS2B5.rck Page 3 of 9 Section - # Foundation Inspection Plans Verified Field Verified Value ._Value Complies? Comments/Assumptions & RepilD. 402.1.1 Conditioned basement wall R- R- ;❑Complies I See the Envelope Assemblies [F0411 :insulation R -value. Where interior; R- R_ I❑Does Not ;table for values. insulation is used, verification ❑Nat Observable ;may need to occur during Applicable :insulation Inspection. Not❑Not ;required in warm -humid locations; in Climate Zone 3. 303.2 ;Conditioned basement wall rW,v +.❑Complies [F05]1 :insulation installed per n�#tt fi` s' _ " ❑Does Not ;manufacturer's instructions. []Not Observable ❑Not Applicable 402.2.8 (Conditioned basement wall It ft❑Complies See the Envelope Assemblies [F0611 insulation depth of burial or ;❑Does Not ;table for values. i4 distance from top of wall. ;❑Not Observable ONot Applicable 303.2.1 'A protective covering is installed irawM'�rr '* 'kl ❑Complies [F011]1 'to protect exposed exterior t=k "r Ff ❑Does Not � insulation and extends a -;minimum 6 in. below rade x �# ' r� ❑Not Observable of g, r,=* " �❑Not Applicable j 403.8, :Snow- and ice -melting system. :� r'�`.��:y, xi ❑Complies [F01212 controls installed. " s nk", *^-� ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2). 3 I Low Impact (Tier 3) Project Title: FS2B5 - SAVANNAH Report date: 09/12/16 Data filename: C:\Users\jhoel lei n\Documents\REScheck\FS2B5.rck Page 4 of 9 'Section, # Framing / Rough -In Inspection 'Plans Verified FieldVerified ' Value (. l Value Complies? Comments/Assumptions: & Req.ID 402.1.1, ;Door U -factor. ;U-_ U -❑Complies See the Envelope Assemblies 402.3.4❑Does Not table for values. [PRI]1 ;❑Not Observable ❑Not Applicable 402.1.1, .Glazing U-factor(area-weighted U-_ U-_ Complies ;See the Envelope Assemblies 402.3.1, ;average).❑Does Not (table for values. 402.3.3, 402.3.6,❑Not Observable 402.5❑Not Applicable [FR2]1 303.1.3 U -factors of fenestration products ❑Complies [FR4]1 :are determined in accordance t`„ ❑Does Not 9 ;with the NFRC test procedure or ;taken from the default table�x w h `�❑Not Observable j ❑Not Applicable 402.4.1.1 .Air barrier and thermal barrier❑Complies In t r �, aw [FR2311 :installed per manufacturers �f ". *', ❑Does Not ;instructions. J, ':❑Not Observable M❑ la. „, Not Applicable 402.4.3 'Fenestration that is not site builtr2 N ," ❑Complies ' [FR20]1 ;is listed and labeled as meeting x sx. ❑Does Not AAMA /WDMA/CSA 101/1.5 2/A440 r"'' r c ❑Not Observable or has infiltration rates pe NFRC ;400 that do not exceeds ode " c`fi "Um., r` "�F� " `' �;_ ❑Not Applicable limits. r 402,4.4 ,IC -rated recessed lighting fixtures z ❑Complies [FRi6]2 'sealed at housing/interior finish , "- "mat ��`�� ❑ jand labeled to indicate 'leakage at 75 Pa. ❑Not Observable ❑Not Applicable 403.2.1 'Supply ducts in attics are ; R- R- I❑Complies [FR12]1 :insulated to >_R-8. All other ducts R_ R_❑DoesNot lin unconditioned spaces or loutside the building envelope are; ;❑Not Observable i insulated to >_R-6.❑Not Applicable 403.2.2 'All joints and seams of air ducts �� �' : r ';a r ` 3t t"". ❑Complies [FR1311 lair handlers, and filter boxes are , ''.r �., ❑Does Not ,sea,led. s,? [�'�` ❑Not Observable x 1 �''a:. '' ❑Not Applicable 403.23, ! Building cavities are not used as n'== '�,, mss- �, ,� '-'dr ,'. ❑Complies [FR , !ducts ! ducts or plenums. ` -',,ry '✓b=` +"4 y ❑Does Not i ❑Not Observable ❑Not Applicable 403.3 ;HVAC piping conveying fluids 1 R- ; R- ;❑Complies [FRI7]2 (above 105 OF or chilled fluids ;❑Does Not below 55 PF are insulated to aR- ; j❑Not Observable '3. ❑Not Applicable 403.3.1 [FR24]1 .Protection of insulation on HVAC- .piping.^. ' ❑Complies 'r ❑Does Not 1*s `u ❑Not Observable a 1a s. ❑Not Applicable 403.4.2 Hot water pipes are insulated to R-_ R -_❑Complies [FR18]2 ;>_R-3.❑Does Not ;❑Not Observable ❑Not Applicable 1 I High Impact (Tier 1) 12. Medium Impact (Tier 2) 1- 3 I Low Impact (Tier 3) Project Title: FS2135 - SAVANNAH Report date: 09/12/16 Data filename: C:\Users\jhoellein\Documents\REScheck\FS2B5.rck Page 5 of 9 Section # Framing / Rough -In Inspection Plans Verified Field Complies? Comments/Assumptions & Req.ID Value Value ..Value 403.5 :'Automatic or gravity dam ers areV a x "t `-. `i "" � ' `fit' ❑Complies TFR19]� (installed on all outdoor air []Does Not (intakes and exhausts. []Not Observable ; ❑NotA Additional Comments/Assumptions: 1 High Impact (Tier 1) 1,2l' Medium Impact (Tier 2) 13'. Low Impact (Tier 3) Project Title: FS2B5 - SAVANNAH Report date:09/12/16 Data filename: C:\Users\jhoellein\Documents\REScheck\FS2B5.rck Page 6 of 9 Section: # Insulation Inspection .Plans Verified :Value Field Verified Value Complies? Comments/Assumptions'. Re .ID. 303.1 'All installed insulation is labeled El Complies [IN13]2 Ior the installed R -values �'_• ❑Does Not provided:, -x "� ` +� n .,, ❑Nat Observable "-❑Not Applicable .ti 402.1.1, Floor insulation R -value. R-. R-_ ;❑Complies ; See the Envelope Assemblies 402.2.6 ❑ Wood ❑ Wood❑Does Not ;table for values. [IN111 I ❑ Steel ❑ Steel❑Not Observable ❑Not Applicable 303 .2, Floor insulation installedper " r ❑Complies 402.2.7 i manufacturer's instructions and +` ❑Does Not [IN211 in substantial contact with the *a ," v. `}vr `' ' ' r❑Not Observable underside of the subfloor. Iii*, (a>.� r.• day, �;❑Not Applicable er. ,f , ,� 402.1.1, ;Wall insulation R -value. If this is a: R- R- ❑Complies ;See the Envelope Assemblies 402.2.5, mass wall with at least'/z of the ❑ Wood ❑ Wood I❑Does Not ;table for values. 402.2.6 ;wall insulation on the wall ❑ Mass ❑ Mass ;❑Not Observable [IN311 qj i exterior, the exterior insulation I requirement applies (FR10). ❑ Steel ❑ Steel ❑Not Applicable i ,❑Complies 303.2 Mall insulation is installed per [IN4]1 ;manufacturer's instructions'[]Does Not ❑Not Observable i - *", *,'„ ❑Not Applicable _.. Additional Comments/Assumptions: 1 I High Impact (Tier 1) 12' Medium Impact (Tier 2) 1311 Low Impact (Tier 3) Project Title: FS2B5 - SAVANNAH Report date: 09/12/16 Data filename: C:\Users\jhoel lei n\Documents\REScheck\FS2B5.rck Page 7 of 9 Section # ` .Final Inspection Provisions :. Plans Verified Field Verified Value Value Complies? Comments/Assumptions' & Req.ID 402.1.1, ;Ceiling insulation R -value. R-_ R- ;❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood❑Does Not table for values. 402.2.2, 402.2.6 I E] Steel ❑ Steel :❑Not Observable [Fill'❑Not Applicable V� 303.1.1.1, ;Ceiling insulation installed per s sx "M h Alh ❑Complies 303.2 :manufacturer's instructions :Blown aB�`ay" ', ❑Does Not [F12]1 insulation marked every 1300 ft'. ❑Not Observable U ❑Not Applicable 402 2 3 [1712212 ;Vented attics with air permeable !it include baffle adjacent ai­ xis F ^-,w, ''"''Jt r ��a '.'❑Complies ❑Does Not ;to soffit and eave vents that �1 "s6� '❑Not'Observable extends over insulation. _�." ❑Not Applicable 402.2.4 ;Attic access hatch and door ; R- R -❑Complies [F13]1 !insulation >_R -value of the :❑Does Not 'adjacent assembly. 9) 1❑Not Observable' ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 =_ ACH 50 =_ ❑Complies [F11711 ach in Climate Zones 1-2, and❑Does Not <=3 ach in Climate Zones 3-8.❑Not Observable ❑Not Applicable 403.2.2: Duct tightness test result of <=4 ; cfm/100 cfm/100 ;❑Complies [FI4]1 cfm/100 ft2 across the system or ;ftp ftp ❑Does Not i LG)<=3 cfm/100 ft2 without air ;❑Not Observable :handler@ 25 Pa. For rough -in - , ;❑Not Applicable i tests, verification may need to .occur during Framing Inspection. 403.2.2.1 ;Air handler leakage designated 'by ��� x<pk '❑Complies [F12411 manufacturer at <=2% of i ,>�'� '�r,. ❑Does Not g Idesign air flow.xd r ,, s {❑Not Observable I ❑Not Applicable .":01, ., .i.,. 40311 ! Programmable thermostats s.'f ,Ax f h ❑Complies (1719]?_i installed on forced air furnaces $ �,, ir,; . ❑Does Not ❑Not Observable ❑Not Applicable 803.1.2 ;Heat pump thermostat installed � � �� '�"c.i's*„UoComplies [FI10]? on heat pumps. s fs, 4 r❑Does Not-]Not1Not NE Observable ❑Not Applicable 403.4.1, [F11112 'Circulating service hot water systems have automatic or sy.�' azo'. Ys,��m, t v ''x , atk] ~ ,i` '{fir ❑Complies ❑Does Not ;accessible manual controls Fe<(, s s � s *s r rar'�� ss`�r* kx l s, ❑Not Observable �s, ❑Not Applicable 403.5.1 All mechanical ventilation system <,:.'" `'�"Iff '. ❑Complies (FI2573fans not part of tested and listed❑Does Not HVAC equipment meet efficacy flow ,. n )aand Observable air limits.°❑Not ❑Not Applicable 404.1 175% of lamps in permanent; <4 .. ❑Complies [F1611 :fixtures or 75% of permanent ❑Does Not v .fixtures have high efficacy lamps fs ❑Not Observable Does not apply to low -voltage lighting. x .„ r', (" <s ❑Not Applicable Pp 1 I High Impact (Tier 1) 1 2. Medium Impact (Tier 2) 1 31.1 Low Impact (Tier 3) Project Title: FS2135 - SAVANNAH Report date: 09/12/16 Data filename: C:\Users\jhoellein\Documents\REScheck\FS2B5.rck Page 8 of 9 Section # i Final Inspection Provisions Plans Verified Field. Verified ` Complies? Comments/Assumptions & Req.113 Value Value 404.1.1 !Fuel gas lighting systems have `;s�4 +� + SA ❑Complies tFI23]3 no continuous pilot light. ++ j g y, u, '��;` ^.. ❑Does Not L; ❑Not Observable ' ❑Not Applicable 401.3 jF1712 ;Compliance certificate posted. ' ❑Complies []Does Not U �c�r + ❑Not Observable ❑Not Applicable 903,3 Manufacturer manuals for❑Complies heating w qtr Y &V w km v' . �`�t.. ,7 �" �` x]5.1 `; ❑Does [FI18]3 i mechanical and water x Not -' s stems have been rovidedx� ; y p.i4 ` 1❑Not Observable ,„ .. ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact (Tier 1) 12'1 Medium Impact (Tier 2) 3 -1 Low Impact (Tier 3) Project Title: FS2B5 - SAVANNAH Report date: 09/12/16 Data filename: C:\Users\jhoellein\Documents\REScheck\FS2B5.rck Page 9 of 9 '0 d 2012 IECC Energy Efficiency Certificate Above -Grade Wall 22.00. Below -Grade Wall 19.00 Floor 30.00 Ceiling / Roof 50.00 Ductwork (unconditioned spaces): Glass & Door Rating U -Factor SHGG Window 0.33 Door 0.17 Heating System: Cooling System: Water Heater., Name: _ Comments