HomeMy WebLinkAboutRESCHECK - 16-00644 - 1121 Adams Ct - SFR1ZRE check Software Version 4.6.2
Compliance Certificate
Project FS2B5 - SAVANNAH
Energy Code:
2012 IECC
Location:
Rexburg, Idaho
Construction Type:
Single-family
Project Type:
New Construction
Orientation:
Bldg. faces 270 deg. from North
Conditioned Floor Area:
3,639 ft2
Glazing Area
15%
Climate Zone:
6 (8693 HDD)
Permit Date:
Permit Number:
Construction Site:
Owner/Agent:
1121 ADAMS Cr.
REXBURG, ID, 83440
Designer/Contractor:
601 w. 1700 s
Logan, UT 84321
john@kartchnerhomes.com
Compliance: 0.3% Better Than Code Maximum UA: 362 Your UA: 361
The % Better or Worse Than Code Index reflects haw close to compliance the house Is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home..
Envelope Assemblies
Ceiling 1: Flat Ceiling or Scissor Truss
Second Wall Front: Wood Frame, 16" D.C.
Orientation: Front
Window 1: Vinyl/Fiberglass Frame:Double Pane with Low -E
Orientation: Front
Second Wall Right: Wood Frame, 16" D.C.
Orientation: Right side
Window 7: Vinyl/Fiberglass Frame:Double Pane with Low -E
Orientation: Right side
Second Wall Rear: Wood Frame, 16" D.C.
Orientation: Back
Window 2: Vinyl/Fiberglass Frame:Double Pane with Low -E
Orientation: Back
Second Wall Left: Wood Frame, 16" D.C.
Orientation: Left side
Second floor over garage: All -Wood Joist/rruss:Over Unconditioned Space
Main Wall Front: Wood Frame, 16" D.C.
Orientation: Front
Window 4: Vinyl/Fiberglass Frame:Double Pane with Low -E
Orientation: Front
Door 1: Solid
Orientation: Front
1,527
344
87
304
24
312
76
304
383
480
30
53
50.0. 0.0
22.0 0.0
22.0 0.0
22.0 0.0
22.0 0.0
30.0 0.0
22.0 0.0
0.056 14
0.330 29
0.056 16
0.330 8
0.056 13
0.330 25
0.056 17
0.033 13
0.056 22
0.330 10
0.170 9
Project Title: FS2B5 - SAVANNAH Report dater 09/12/16
Data filename: C:\Users\jhoellein\Documents\REScheck\FS2B5.rck Page 1 of 9
Main Wall Right: Wood Frame, 16" o.c.
342
22.0.
0.0
0.056
19
Orientation: Right side
Main Wall Rear: Wood Frame, 16" o.c.
366
22.0
0.0
0.056
13'.
.Orientation: Back
Window 5: Vinyl/Fiberglass Frame:Double Pane with Low -E
132
0.330
44
Orientation: Back
Main Wall Left: Wood Frame, 16" o.c..
213
22.0
0.0
0.056
12
Orientation: Left side
Floor 2:. All -Wood joist/Truss:Over Outside Air
20
30.0
0.0
0.033
1
Basement Wall Front: Solid Concrete or Masonry
427
0.0
19.0
0.036
15
Orientation: Front
Wall height: 8.0'
Depth below grade: 8.0'
Insulation depth: 8.0'
Basement Wall Right: Solid Concrete or Masonry
304
0.0
19.0
0.036
11
Orientation: Right side
Wall height: 8.0'
Depth below grade: 8.0'
Insulation depth: 8.0'
Basement Wall Rear: Solid Concrete or Masonry
312
0.0
19.0
0.036
10
Orientation: Back
Wall height: 8.0'
Depth below grade: 8.0'
Insulation depth:. 8.0'
Window 8: Vinyl/Fiberglass Frame:Double Pane with Low -E
40
0.330
13
Orientation: Back
Basement Wall Left: Solid Concrete or Masonry
189
0.0
19.0.
0.036
7
Orientation: Left side
Wall height: 8.0'
Depth below grade: 8.0'
Insulation depth: 8.0'
Compliance Statement: The proposed building design described here is consistent with the building plans,
specifications, and other
calculations submitted with the permit application. The proposed building
has been designed to
meet the 2012
IECC requirements
in
REScheck Version 4.6.2 and to comply with the mandatory requirements listed
in the REScheck
Inspection Checklist.
Date
Project Notes:
"SAVANNAH"
Founder Square Subd.
Block: 5, Lot: 2,.
Project Title: FS265 -SAVANNAH Report date: 09/12/16
Data filename: C:\Users\jhoellein\Documents\REScheck\FS2B5.rck Page 2 of 9
REScheck Software Version 4.6.2
Inspection Checklist
Energy Code: 2012 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
#
Pre-Inspection/Plan Review
tans Verified , Fleld Verlfled '. '
;'Value.:.'. 7 Complies? Comments/Assumptions
Req.ID.:.�
-Value
103.1.
!Construction drawings and
�,
❑Complies
103.2
documentation demonstrate
i
a❑Does Not
[PRI]1
;energy code compliance for the
,, ,'„.* 'I
❑Not Observable;
u
;building envelope.
❑Not Applicable
103 1,
,Construction drawings and
tea. k�i Ai
i
x asr x r,. ❑Complies
'f" ❑Does
103.2,
;documentation demonstrate
r "
,`��' Not
403.7
: energy code compliance for
{
Observable
[PR3]1
!lighting and mechanical systems
'�1x.r;
❑Not
Systems serving multiple
"+f ,`
°- ❑Not Applicable
dwelling units must demonstrate'/
I compliance with the IECC
Commercial Provisions.
342.1,
Heating and cooling equipment is;
Heating:
Heating:❑Complies
403.6
J sized per ACCA Manual 5 based
Btu/hr _
Btu/hr❑Does
Not
[PR2]2
'..
;; on loads calculated per ACCA
Cooling:
Cooling:
Observable
V
Manual J or other methods
approved by the code official.
I
Btu/hr
Btu/hr
;❑Not Applicable
Additional Comments/Assumptions:
1 I High Impact (Tier 1) 12, 1 Medium Impact (Tier 2) 13, 1 Low Impact (Tier 3)
Project Title: FS285 - SAVANNAH Report date: 09/12/16
Data filename: C:\Users\jhoellein\Documents\REScheck\FS2B5.rck Page 3 of 9
Section
- #
Foundation Inspection
Plans Verified Field Verified
Value ._Value Complies? Comments/Assumptions
& RepilD.
402.1.1
Conditioned basement wall
R- R-
;❑Complies I See the Envelope Assemblies
[F0411
:insulation R -value. Where interior;
R- R_
I❑Does Not ;table for values.
insulation is used, verification
❑Nat Observable
;may need to occur during
Applicable
:insulation Inspection. Not❑Not
;required in warm -humid locations;
in Climate Zone 3.
303.2
;Conditioned basement wall
rW,v +.❑Complies
[F05]1
:insulation installed per
n�#tt fi` s' _
"
❑Does Not
;manufacturer's instructions.
[]Not Observable
❑Not Applicable
402.2.8
(Conditioned basement wall
It
ft❑Complies
See the Envelope Assemblies
[F0611
insulation depth of burial or
;❑Does Not ;table for values.
i4
distance from top of wall.
;❑Not Observable
ONot Applicable
303.2.1
'A protective covering is installed
irawM'�rr
'* 'kl ❑Complies
[F011]1
'to protect exposed exterior
t=k "r
Ff ❑Does Not
� insulation and extends a
-;minimum 6 in. below rade
x �# ' r�
❑Not Observable
of g,
r,=* "
�❑Not Applicable j
403.8,
:Snow- and ice -melting system.
:� r'�`.��:y,
xi
❑Complies
[F01212
controls installed.
"
s nk",
*^-�
❑Does Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2). 3 I Low Impact (Tier 3)
Project Title: FS2B5 - SAVANNAH Report date: 09/12/16
Data filename: C:\Users\jhoel lei n\Documents\REScheck\FS2B5.rck Page 4 of 9
'Section,
#
Framing / Rough -In Inspection
'Plans Verified FieldVerified '
Value (. l Value
Complies? Comments/Assumptions:
& Req.ID
402.1.1,
;Door U -factor.
;U-_ U -❑Complies
See the Envelope Assemblies
402.3.4❑Does
Not table for values.
[PRI]1
;❑Not Observable
❑Not Applicable
402.1.1,
.Glazing U-factor(area-weighted
U-_ U-_
Complies ;See the Envelope Assemblies
402.3.1,
;average).❑Does
Not (table for values.
402.3.3,
402.3.6,❑Not
Observable
402.5❑Not
Applicable
[FR2]1
303.1.3
U -factors of fenestration products
❑Complies
[FR4]1
:are determined in accordance
t`„
❑Does Not
9
;with the NFRC test procedure or
;taken from the default table�x
w h
`�❑Not Observable
j
❑Not Applicable
402.4.1.1
.Air barrier and thermal barrier❑Complies
In t r �,
aw
[FR2311
:installed per manufacturers
�f ". *',
❑Does Not
;instructions.
J, ':❑Not Observable
M❑
la. „, Not Applicable
402.4.3
'Fenestration that is not site builtr2
N ,"
❑Complies
'
[FR20]1
;is listed and labeled as meeting
x sx.
❑Does Not
AAMA /WDMA/CSA 101/1.5 2/A440
r"''
r
c ❑Not Observable
or has infiltration rates pe NFRC
;400 that do not exceeds ode
" c`fi
"Um., r` "�F� "
`'
�;_ ❑Not Applicable
limits.
r
402,4.4
,IC -rated recessed lighting fixtures z
❑Complies
[FRi6]2
'sealed at housing/interior finish
,
"- "mat ��`��
❑
jand labeled to indicate
'leakage at 75 Pa.
❑Not Observable
❑Not Applicable
403.2.1
'Supply ducts in attics are
; R- R-
I❑Complies
[FR12]1
:insulated to >_R-8. All other ducts
R_ R_❑DoesNot
lin unconditioned spaces or
loutside the building envelope are;
;❑Not Observable
i insulated to >_R-6.❑Not
Applicable
403.2.2
'All joints and seams of air ducts
�� �' : r ';a r ` 3t t"". ❑Complies
[FR1311
lair handlers, and filter boxes are
, ''.r
�.,
❑Does Not
,sea,led.
s,?
[�'�`
❑Not Observable
x 1
�''a:.
'' ❑Not Applicable
403.23,
! Building cavities are not used as
n'== '�,, mss- �, ,� '-'dr ,'.
❑Complies
[FR ,
!ducts
! ducts or plenums.
` -',,ry '✓b=` +"4 y
❑Does Not i
❑Not Observable
❑Not Applicable
403.3
;HVAC piping conveying fluids
1 R- ; R-
;❑Complies
[FRI7]2
(above 105 OF or chilled fluids
;❑Does Not
below 55 PF are insulated to aR-
;
j❑Not Observable
'3.
❑Not Applicable
403.3.1
[FR24]1
.Protection of insulation on HVAC-
.piping.^.
' ❑Complies
'r ❑Does
Not
1*s `u ❑Not Observable
a
1a s.
❑Not Applicable
403.4.2
Hot water pipes are insulated to
R-_ R -_❑Complies
[FR18]2
;>_R-3.❑Does
Not
;❑Not Observable
❑Not Applicable
1 I High Impact (Tier 1) 12. Medium Impact (Tier 2) 1- 3 I Low Impact (Tier 3)
Project Title: FS2135 - SAVANNAH Report date: 09/12/16
Data filename: C:\Users\jhoellein\Documents\REScheck\FS2B5.rck Page 5 of 9
Section
#
Framing / Rough -In Inspection
Plans Verified Field
Complies? Comments/Assumptions
& Req.ID
Value
Value ..Value
403.5
:'Automatic or gravity dam ers areV
a x "t `-. `i "" � ' `fit'
❑Complies
TFR19]�
(installed on all outdoor air
[]Does Not
(intakes and exhausts.
[]Not Observable ;
❑NotA
Additional Comments/Assumptions:
1 High Impact (Tier 1) 1,2l' Medium Impact (Tier 2) 13'. Low Impact (Tier 3)
Project Title: FS2B5 - SAVANNAH Report date:09/12/16
Data filename: C:\Users\jhoellein\Documents\REScheck\FS2B5.rck Page 6 of 9
Section:
#
Insulation Inspection
.Plans Verified
:Value
Field Verified
Value Complies? Comments/Assumptions'.
Re .ID.
303.1
'All installed insulation is labeled
El Complies
[IN13]2
Ior the installed R -values
�'_•
❑Does Not
provided:,
-x
"� ` +� n
.,, ❑Nat Observable
"-❑Not Applicable
.ti
402.1.1,
Floor insulation R -value.
R-. R-_
;❑Complies ; See the Envelope Assemblies
402.2.6
❑ Wood ❑ Wood❑Does
Not ;table for values.
[IN111
I ❑ Steel ❑ Steel❑Not
Observable
❑Not Applicable
303 .2,
Floor insulation installedper
" r
❑Complies
402.2.7
i manufacturer's instructions and
+`
❑Does Not
[IN211
in substantial contact with the
*a ," v. `}vr
`' ' '
r❑Not Observable
underside of the subfloor.
Iii*, (a>.�
r.• day, �;❑Not Applicable
er. ,f , ,�
402.1.1,
;Wall insulation R -value. If this is a: R- R-
❑Complies ;See the Envelope Assemblies
402.2.5,
mass wall with at least'/z of the
❑ Wood ❑ Wood
I❑Does Not ;table for values.
402.2.6
;wall insulation on the wall
❑ Mass ❑ Mass
;❑Not Observable
[IN311
qj
i exterior, the exterior insulation
I requirement applies (FR10).
❑ Steel ❑ Steel
❑Not Applicable
i
,❑Complies
303.2
Mall insulation is installed per
[IN4]1
;manufacturer's instructions'[]Does
Not
❑Not Observable i
- *", *,'„ ❑Not Applicable _..
Additional Comments/Assumptions:
1 I High Impact (Tier 1) 12' Medium Impact (Tier 2) 1311 Low Impact (Tier 3)
Project Title: FS2B5 - SAVANNAH Report date: 09/12/16
Data filename: C:\Users\jhoel lei n\Documents\REScheck\FS2B5.rck Page 7 of 9
Section
#
`
.Final Inspection Provisions
:. Plans Verified Field Verified
Value Value
Complies? Comments/Assumptions'
& Req.ID
402.1.1,
;Ceiling insulation R -value.
R-_ R-
;❑Complies See the Envelope Assemblies
402.2.1,
❑ Wood ❑ Wood❑Does
Not table for values.
402.2.2,
402.2.6
I
E] Steel ❑ Steel :❑Not
Observable
[Fill'❑Not
Applicable
V�
303.1.1.1,
;Ceiling insulation installed per
s sx "M h Alh ❑Complies
303.2
:manufacturer's instructions
:Blown
aB�`ay"
', ❑Does Not
[F12]1
insulation marked every
1300 ft'.
❑Not Observable
U
❑Not Applicable
402 2 3
[1712212
;Vented attics with air permeable
!it include baffle adjacent
ai
xis F ^-,w, ''"''Jt
r ��a
'.'❑Complies
❑Does Not
;to soffit and eave vents that
�1
"s6� '❑Not'Observable
extends over insulation.
_�."
❑Not Applicable
402.2.4
;Attic access hatch and door
; R- R -❑Complies
[F13]1
!insulation >_R -value of the
:❑Does
Not
'adjacent assembly.
9)
1❑Not Observable'
❑Not Applicable
402.4.1.2
Blower door test @ 50 Pa. <=5
ACH 50 =_ ACH 50 =_
❑Complies
[F11711
ach in Climate Zones 1-2, and❑Does
Not
<=3 ach in Climate Zones 3-8.❑Not
Observable
❑Not Applicable
403.2.2:
Duct tightness test result of <=4
; cfm/100 cfm/100
;❑Complies
[FI4]1
cfm/100 ft2 across the system or
;ftp ftp
❑Does Not i
LG)<=3
cfm/100 ft2 without air
;❑Not Observable
:handler@ 25 Pa. For rough -in
-
,
;❑Not Applicable
i tests, verification may need to
.occur during Framing Inspection.
403.2.2.1
;Air handler leakage designated
'by
��� x<pk '❑Complies
[F12411
manufacturer at <=2% of
i ,>�'�
'�r,.
❑Does Not
g
Idesign air flow.xd
r ,, s
{❑Not Observable
I
❑Not Applicable
.":01,
., .i.,.
40311
! Programmable thermostats
s.'f ,Ax f h
❑Complies
(1719]?_i
installed on forced air furnaces
$ �,, ir,; .
❑Does Not
❑Not Observable
❑Not Applicable
803.1.2
;Heat pump thermostat installed
� � �� '�"c.i's*„UoComplies
[FI10]?
on heat pumps.
s fs, 4 r❑Does Not-]Not1Not
NE
Observable
❑Not Applicable
403.4.1,
[F11112
'Circulating service hot water
systems have automatic or
sy.�' azo'. Ys,��m, t v ''x
, atk] ~ ,i`
'{fir
❑Complies
❑Does Not
;accessible manual controls
Fe<(, s s
�
s *s r rar'�� ss`�r* kx l
s, ❑Not Observable
�s,
❑Not Applicable
403.5.1
All mechanical ventilation system
<,:.'" `'�"Iff '. ❑Complies
(FI2573fans
not part of tested and listed❑Does
Not
HVAC equipment meet efficacy
flow
,. n )aand
Observable
air limits.°❑Not
❑Not Applicable
404.1
175% of lamps in permanent;
<4 ..
❑Complies
[F1611
:fixtures or 75% of permanent
❑Does Not
v
.fixtures have high efficacy lamps
fs
❑Not Observable
Does not apply to low -voltage
lighting.
x .„ r', (" <s
❑Not Applicable
Pp
1 I High Impact (Tier 1) 1 2. Medium Impact (Tier 2) 1 31.1 Low Impact (Tier 3)
Project Title: FS2135 - SAVANNAH Report date: 09/12/16
Data filename: C:\Users\jhoellein\Documents\REScheck\FS2B5.rck Page 8 of 9
Section
#
i Final Inspection Provisions
Plans Verified Field. Verified
`
Complies? Comments/Assumptions
& Req.113
Value Value
404.1.1
!Fuel gas lighting systems have
`;s�4 +� + SA
❑Complies
tFI23]3
no continuous pilot light.
++ j g y, u, '��;` ^..
❑Does Not
L;
❑Not Observable '
❑Not Applicable
401.3
jF1712
;Compliance certificate posted.
'
❑Complies
[]Does Not
U �c�r +
❑Not Observable
❑Not Applicable
903,3
Manufacturer manuals for❑Complies
heating
w qtr Y &V w km v' .
�`�t.. ,7 �" �` x]5.1 `;
❑Does
[FI18]3
i mechanical and water
x
Not
-'
s stems have been rovidedx�
; y p.i4
`
1❑Not Observable
,„
..
❑Not Applicable
Additional Comments/Assumptions:
1 I High Impact (Tier 1) 12'1 Medium Impact (Tier 2) 3 -1 Low Impact (Tier 3)
Project Title: FS2B5 - SAVANNAH Report date: 09/12/16
Data filename: C:\Users\jhoellein\Documents\REScheck\FS2B5.rck Page 9 of 9
'0 d
2012 IECC Energy
Efficiency Certificate
Above -Grade Wall 22.00.
Below -Grade Wall 19.00
Floor 30.00
Ceiling / Roof 50.00
Ductwork (unconditioned spaces):
Glass & Door Rating U -Factor SHGG
Window 0.33
Door 0.17
Heating System:
Cooling System:
Water Heater.,
Name: _
Comments