Loading...
HomeMy WebLinkAboutRESCHECK - 16-00658 - 864 S 2275 W - SFRREScheck Software Version 4.6.2 Compliance Certificate Project SF11B2 - DAVENPORT Energy Code: 2012 IECC Location: Rexburg, Idaho Construction Type: Single-family Project Type: New Construction Orientation: Bldg. faces 90 deg. from North Conditioned Floor Area: 2,204 ft2 Glazing Area 9% Climate Zone: 6 (8693 HDD) Permit Date: Permit Number: 30 Construction Site: RESBURG, ID 83440 Better Than Code Envelope Assemblies Owner/Agent: Designer/Contractor: Kartchner Homes Logan, UT 84321 Ceiling 1: Flat Ceiling or Scissor Truss 1,446 50.0 0.0 0.026 38 Main Wall Front: Wood Frame, 16" o.c. 432 22.0 0.0 0.056 21 Orientation: Front Window 4: Vinyl/Fiberglass Frame:Double Pane with Low -E 30 0.300 9 SHGC: 0.32 Orientation: Front Door 1: Solid 20 0.170 3 Orientation: Front Main Wall Right: Wood Frame, 16" o.c. 324 22.0 0.0 0.056 17 Orientation: Right side Window 7: Vinyl/Fiberglass Frame:Double Pane with Low -E 25 0.300 8 SHGC: 0.32 Orientation: Right side Main Wall Rear: Wood Frame, 16" o.c. 336 22.0 0.0 0.056 15 Orientation: Back Window 5: Vinyl/Fiberglass Frame:Double Pane with Low -E 51 0.300 15 SHGC: 0.32 Orientation: Back Door 2: Glass 20 0.170 3 SHGC: 0.32 Orientation: Back Main Wall Left: Wood Frame, 16" o.c. 312 22.0 0.0 0.056 17 Orientation: Left side BASEMENT WALL FRONT: Wood Frame, 16" o.c. 131 22.0 0.0 0.056 7 Orientation: Front Project Title: SF11132 - DAVENPORT Report date: 09/21/16 Data filename: C:\Users\jhoellein\Documents\REScheck\SF11B2 - DAVENPORT.rck Page 1 of 9 BASEMENT WALL LEFT: Wood Frame, 16" o.c. Orientation: Left side Window 9: Vinyl/Fiberglass Frame:Double Pane with Low -E SHGC: 0.32 Orientation: Left side BASEMENT WALL REAR: Wood Frame, 16" o.c. Orientation: Back Window 8: Vinyl/Fiberglass Frame:Double Pane with Low -E SHGC: 0.32 Orientation: Back Basement - FOUNDATION WALL: Solid Concrete or Masonry Orientation: Front Wall height: 3.0' Depth below grade: 3.0' Insulation depth: 3.0' Crawl 1: Solid Concrete or Masonry Wall height: 3.0' Depth below grade: 3.0' Insulation depth: 3.0' Mechanical Equipment 174 20 156 20 22.0 0.0 0.056 9 0.300 6 22.0 0.0 0.056 8 0.300 6 232 0.0 269 0.0 21.0 0.039 9 21.0 0.041 7 Forced Hot Air Gas 96 AFUE Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in REScheck Version 4.6.2 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. IIdIIIC - I ILIO Project Notes: DAVENPORT Summerfield Subd. Block: 2, Lot: 11 Date Project Title: SF11132 - DAVENPORT Report date: 09/21/16 Data filename: C:\Users\jhoellein\Documents\REScheck\SF11B2 - DAVENPORT.rck Page 2 of 9 CREScheck Software Version 4.6.2 �J( Inspection Checklist Energy Code: 2012 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. section '# ' Pre-Inspection/Plan Review Plans Verified Field Verified Value Value Complies? Comments/Assumptions` & Req.ID 103.1,Construction drawings and ._;� �., ar�'tW .."', ❑Complies 103.2 documentation demonstrate -r. ❑Does Not [PR1]1 ;energy code compliance forthe building `. x s. ❑Not Observable 0 envelope. a II �nq:; ` ❑Not Applicable 103.1, ;Construction drawings and ''[ =❑Complies 103.2, .documentation demonstrate i< "❑Does Not 403.7 ;energy code compliance for[PR3]1 ❑Not Observable ;lighting and mechanical systems x.,, 1r ,., ti� !Systems serving multiple t',- �^ t, ❑Not Applicable If dwelling units must demonstrate,compliance with the !ECCjCommercial Provisions. ,, 302.1, Heating and cooling equipment is ]Heating: Heating: ❑Complies 403.6 ;sized per ACOA Manual S based Btu/hr Btu/hr_❑Does Not [PR2]7 !on loads calculated per ACCA Cooling: Cooling: ❑Not Observable 'g) Manual ] or other methods by Btu/hr_ ;Btu/hr ;❑Not Applicable PP approved the code official. E Additional Comments/Assumptions: 1 I High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 1 3'1 Low Impact (Tier 3) Project Title: SF11B2 - DAVENPORT Report date: 09/21/16 Data filename: C:\Users\jhoe] lei n\Documents\REScheck\SF11B2 - DAVENPORT.rck Page 3 of 9 section # Foundation Inspection Plans Verified FieldVerified' Value Value Complies? '{omments/Assumptions & Req.ID 402.1.1 (Conditioned basement wall R-_ R -_❑Complies ;See the Envelope Assemblies [F0411 (insulation R -value. Where interior; R- R_❑Does Not ;table for values. !insulation is used, verification ;❑Not Observable ;may need to occur during (Insulation Inspection. Not !❑Not Applicable 'required in warm -humid locations in Climate Zone 3. 303.2 ;Conditioned basement wall '•; P " :{❑Complies [FO511 !insulation installed per i .', , , �" []Does Not pfd) !manufacturer's instructions i� • .I❑Not Observable ❑Not Applicable 402.2.8 1 Conditioned basement wall ft it ❑Complies ;see the Envelope Assemblies [F0611 !insulation depth of burial or❑Does Not ;table for values. !distance from top of wall. ❑Not Observable !❑Not Applicable 402.2.10 ;Unvented crawl space wall R- R -_❑Complies ;See the Envelope Assemblies [F07]1 !insulation R -value. ! R R_❑Does Not ;table for values. !❑Not Observable !❑Not Applicable 303.2 [F0811 j Unvented crawl space wall !insulation installed , ❑Complies ❑ per �manufacturer's instructions, wk Does Not ❑Not Observable ] "` "•,�`❑Not Applicable 402.2.10 !Unvented crawl space continuous[ ❑Complies [F09]1 'vapor retarder installed over❑Does Not Iexposed earth, joints overlappedko by 6 in. and sealed, extending atf least 6 in. up and attached to the "_�^ ❑Not Observable ❑Not Applicable 'wall. i c� .a " 402.2.9 ! Unvented crawl space wall in. in. ;❑Complies ;See the Envelope Assemblies [FO1011 !insulation depth of burial or _ I❑Does Not ;table for values. 10p !distance from to of wall. :[]Not Observable ❑Not Applicable 303.2.1 , IA [F011]v protective covering is installed protect exposed exterior ' '„?”' x 's `" • []Complies t ,3❑Does Not .Ito imsulation and extends a [ z '� :1❑Not Observable minimum of 6 in, below grade .� "1 , []Not Applicable Applicable 403.8]Snow-and [F012] (controls ice -melting system installed. 1.rF rx , , I ❑Complies • w ❑Does Not 1. j1 wj� t ❑Not Observable j j1 �"❑NotAPP licable Additional Comments/Assumptions: 111 High Impact (Tier 1) 12i1 Medium Impact (Tier 2) 13`1 Low Impact (Tier 3) Project Title: SF11B2 - DAVENPORT Report date: 09/21/16 Data filename: C:\Users\jhoeIlein\Documents\REScheck\SF11B2 - DAVENPORT.rck Page 4 of 9 Section # Framing / Rough -In Inspection Plans Verified Field Verified Value ". Value Complies? Comments/Assumptions & Req.ID - 402.1.1, 1 Door U -factor. U- U- ;[-]Complies See the Envelope Assemblies 402.3.4❑Does DoesNot table for values. [FR1]1 Observable I❑Not Applicable 402.1.1, ;Glazing U-factor(area-weighted U- l U- ❑Complies ;see the Envelope Assemblies 402.3.1, !average).❑Does Not ;table for values. 402.3.3, ;❑Not Observable 402.3.6, 402.5❑Not Applicable [FR2]1 I 303.1.3 U -factors of fenestration products[ fare determined ',i '" 4x " LIC omplies [FR411 in accordance !with the NFRC testrocedure or p c ❑Does Not ' Not Observable ❑ 'taken from the default table. ❑Not Applicable 402.4.1.1 (Air barrier and thermal barrier A ❑Complies [FR23]1 installed per manufacturer's LJ Not !instructions. ' x .r ❑Not Observable ❑Not Applicable 402.4.3 j Fenestration that is not site built " x -� - ". ❑Complies [FR2011 lis listed and labeled as meeting ❑Does Not � IAAMA /WDMA/CSA 101/I.S.2/A440 r i # `; ' ° ❑Not Observable j or has infiltration rates per NFRC ;:,r - "a '� .,y,1 1, ❑Not Applicable ! 1400 that do not exceed code �' ilimits. , i� "P ❑Complies 402.4.4 ;lIC-rated [FR16]2sealed recessed lighting fixtures at housing/interior fin!sh G ° , �� G` 1 ❑Does ;land labeled to indicate <2.0 ,,,�. 4, 1 "� Not ❑Not Observable I leakage at 75 Pa. u i s ❑Not Applicable 405.2 ;All ducts in unconditioned spaces R- R-_ ❑Complies [FR2511 !or outside the building envelope❑Does Not QW);❑Not !are insulated to >11-6. Observable ❑Not Applicable 403.2.2 IAII joints and seams of air ducts, !air AW ❑Complies [FR13]1 handlers, and filter boxes are .d�k❑Does Not 4' sealed. ❑Not Observable k ❑Not Applicable 403:2.3 ;Building cavities are not used as [ .r.....s; ❑Complies [1`111513, (i ducts or plenums. 1 ". .r`w'.. ❑Does Not i [-]Not Observable ❑Not Applicable 403.3 'HVAC piping conveying fluids R- l R -❑Complies [FR17]2 -;above 105 °F or chilled fluids❑Does Not ';below ,'�%1 55.4F are insulated to aR- ;3 ;❑Not Observable 9 I❑Nat Applicable 403.3.1 ;Protection of insulation on HVAC ❑Complies °r( ' ',! [FR24]1 piping. # ❑Does Not 1 111 f�. ❑Not Observable j ❑Not Applicable 403.4.2 {;Hot water pipes are insulated to R- R -_❑Complies [FR18]2 I aR-3.❑Does Not ;❑Not Observable -� ❑Not Applicable 11 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3`1 Low Impact (Tier 3) Project Title: SF11B2 - DAVENPORT Report date: 09/21/16 Data filename: C:\Users\jhoel lei n\Documents\REScheck\SF11B2 - DAVENPORT.rck Page 5 of 9 Section Plans Verified Field Verified # Framing / Rough-In Inspection Value Value Complies? Comments/Assumptions &"Req.ID 403.5 (Automatic or gravity dampers are Ty r$� ❑Complies [FR191� installed on all outdoor air < S ,.. El Does Not �intakes and exhausts. 'c t ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact (Tier 1) 2... Medium Impact (Tier 2) .31 Low Impact (Tier 3) Project Title: SF11132 - DAVENPORT Report date: 09/21/16 Data filename: C:\Users\jhoel lei n\Documents\REScheck\SF11B2 - DAVENPORT.rck Page 6 of 9 Section ' # Insulation Inspection , Plans Verified Field Verified Value -' Value Complies? Comments/Assumptions &Req.ID 303.1 ;JAII installed insulation is labeled €,,," ": ❑Complies =V [IN13]2 _:Iorthe installed R -values ,� ❑Does Not jprovided. [--]Not Observable j ; ai,„ ':u R❑Not Applicable 402.1.1, Wall insulation R -value. If this is a: R- R- ;❑Complies ;See the Envelope Assemblies 402.2.5, mass wall with at least'!z of the ❑ Wood ❑ Wood❑Does Not ;table for values. 402.2.6 !wall insulation on the wall MassMass ❑ ❑ ;❑Not Observable [IN3]1 V ;exterior, the exterior insulation requirement applies (FR10). i i E] Steel E] Steel I❑Not Applicable 303.2 l Wall insulation is installed per (' ❑Complies [IN4]1 !manufacturer's instructions.f❑Does Not []Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: SF11B2 - DAVENPORT Report date: 09/21/16 Data filename: C:\Users\jhoellein\Documents\REScheck\SF11B2 - DAVENPORT.rck Page 7 of 9 " Section # Plans Verified Field Verified Final Inspection Provisions Value Value. Complies? Comments/Assumptions & Req.ID 402.1.1, !Ceiling insulation R -value. i R- R- ;❑Complies See the Envelope Assemblies 402.2.1, I ❑ Wood ❑ Wood I❑Does Not :table for values. 402.2.2, I I ❑ Steel E] Steel ;❑Not Observable j 402.2.6 [Fill' i i I❑Not Applicable 303.1.1.1, (Ceiling insulation installed per ❑Complies 303.2imanufacturer'sinstructlons7 [F12]1 !Blown insulation " x ❑Does Not marked every ❑Not Observable ;300 ft2: : F ❑Not Applicable 402.2.3 [F122]2 ;Vented attics with air permeable !insulation include baffle adjacent k ' r v ❑Complies I I ❑Does Not )to soffit and eave vents that extends over insulation. ❑Not Observable ❑Not Applicable ! 402.4.1.2 I Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 =_ !❑Complies [FI1711 tach in Climate Zones 1-2, and❑Does Not <=3 ach in Climate Zones 3-8. j❑Not Observable ❑Not Applicable 403.2.2 j Duct tightness test result of <=4 cfm/100 cfm/100 ;❑Complies [FI411 !cfm/100 ft2 across the system or ft2 ft2❑Does Not ! <=3 cfm/100 ft2 without air❑Not Observable handler @ 25 Pa. For rough -in jtests, verification may need to ❑Not Applicable !occur during Framing Inspection. 403.2.2.1 [FI24]1 Air handler leakage designated manufacturer at <=2% of UC ',� ` a ; ^'1 '. cl ❑Complies Yt !ff � ❑Does Not +design air flow. !design '4 ❑Not Observable j ;,ati r r;�❑Not Applicable r 403.6,Heating and cooling equipment ❑Complies [FI511 !type and capacity as per plans - va! Sf ❑Does Not f ❑Not Observable ! 4,, , `,`:' + ❑Nat Applicable 403.1.1 [FI9]2 Programmable thermostatsfr installed on forced air furnaces ❑Complies I ` `,a ❑Does 1 ��° Not ❑Not Observable ❑Not Applicable 403.1.2 'Heat ;on pump thermostat installed + i, .; ❑Complies [FI10]2 heat pumps. ❑Does Not. ❑Not Observable as ❑Not Applicable 403,4.1 ; Circulating service hot water❑Complies [FIh]2 -'systems have automatic or ' j# ll , „ , a ❑Does Not accessible manual controls F - ❑Not Observable ( . ,.. ..w ...'. �'.... ❑Not Applicable 403.5.1 All mechanical ventilation system;f ❑Complies [FI2512fans not part of tested and fisted �' € a ? ❑Does Not HVAC equipment meet efficacy t, e r f :. ❑Not Observable .and air flow limits. „ya + , '.aa, ;, _ ❑Not Applicable 404.1 175% of lamps In permanent ,, r.' "i + `' ''' cc omplies [FI611 !fixtures !fixtures or 75% of permanent have high efficacy lamps. n ppg "( 2*`4�❑Does Not a w j Does low h f ar, ❑Not Observable ;lighting.,„.❑Not not apply to -voltage v r _ Applicable ! I I High Impact (Tier 1) 12Medium Impact (Tier 2) 13:1 Low Impact (Tier 3) Project Title: SFllB2 - DAVENPORT Report date: 09/21/16 Data filename: C:\Users\jhoeIlein\Documents\REScheck\SF11B2 - DAVENPORT.rck Page 8 of 9 Section # Final Inspection Provisions :Plans Verified Field Verified Value `. Value Complies? ` Comments/Assumptions. & Re .ID 404,1.1 [1712311 1 Fuel gas lighting systems have Ino continuous pilot light. r' t -J Complies i ❑Does Not ❑Not Observable ❑Not Applicable 401.3 'Compliance certificate posted "� �" '7 ElComplies [FI7.];❑Does x+ Not ❑Not Observable ❑Not Applicable 303.3 j Manufacturer manuals for , "' ;"'", , ❑Complies [FI18]3 imechanical and water heating, Not ]systems have been provided ;�❑Does ,'` .t r -❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 111 High Impact (Tier 1) 1 2'.1 Medium Impact (Tier 2) 1 3!'1 Low Impact (Tier 3) Project Title: SF1182 - DAVENPORT Report date: 09/21/16 Data filename: C:\Users\jhoellein\Documents\REScheck\SF11B2 - DAVENPORT.rck Page 9 of 9 f 2012 IECC Energy Efficiency Certificate Above -Grade Wall 22.00 Below -Grade Wall 21.00 Floor 0.00 Ceiling / Roof 50.00 Ductwork (unconditioned spaces): Window Door 0.30 0.32 0.17 0.32 Forced Hot Air 96 AFUE Cooling System: Water Heater: Name: Date: Comments