HomeMy WebLinkAboutTRUSS SPECS - 16-00777 - 1341 Stone Dr - SFRo _
Nae
I NSs I ype
y
yCapper
Greek lat2 blk3sky meadows
i6-11]653
uol
Common Supponed Gable
1
1
Plate Grp DOL 1.15
TC 0.13
Vert(LL)
0.00 F n/r 120
MT20 220/195
(Roof Snow=35.0)
Job Reference (optional)
BMC(IUAHU YALLb), lu/ OFALLS, IU UMEM
'al3fif4RIA•T::
R0
REACTIONS. All bearings 10-0-0.
(lb)- Max HDrz B=-97(LC 6)
Max Uplift All uplift 100 Ib or less at joint(s) B, F except J=-107(LC 8), H=-106(LC 9)
Max Gmv All reactions 250 Ib or less at joint(s) B, F, I except J=281(LC 1), H=281 (LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES -
1) Wind: ASCE 7-10; Vult=110mph (3 -second gust) Vasd=87mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. Il; Exp C; enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-10; Pf=35.0 psf (Sat roof snow); Category II; Exp C; Fully Exp.; Ct= 1
4) This truss has been designed for greater of min roof live toad of 16.0 psi or 2.00 times flat roof load of 35.0 psf on overhangs
non -concurrent with other live loads.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 2-0-0 cc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrenl with any other live loads.
B)' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) B, F except (jt=1b)
J=107, H=106.
10) Beveled plate or shim required to provide full bearing surface with truss chord atjoint(s) B, F.
11) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
10-0-0
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loo) Wall L/d
PLATES GRIP
TCLL 35.0
Plate Grp DOL 1.15
TC 0.13
Vert(LL)
0.00 F n/r 120
MT20 220/195
(Roof Snow=35.0)
Lumber DOL 1.15
BC 0.06
Vert(TL)
0.00 G n/r 120
TCDL 7.0
Rep Stress Incr YES
WB 0.05
Hom(TL)
0.00 F n/a n/a
BCLL 0.0
Code IBC2012lrP12007
(Matrix)
Weight: 43 lb FT=20%
BCDL 7.0
LUMBER-
BRACING.
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
TOP CHORD Sheathed or 6-0-0 cc purlins.
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Bir
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 DF Stud/Std
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. All bearings 10-0-0.
(lb)- Max HDrz B=-97(LC 6)
Max Uplift All uplift 100 Ib or less at joint(s) B, F except J=-107(LC 8), H=-106(LC 9)
Max Gmv All reactions 250 Ib or less at joint(s) B, F, I except J=281(LC 1), H=281 (LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES -
1) Wind: ASCE 7-10; Vult=110mph (3 -second gust) Vasd=87mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. Il; Exp C; enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-10; Pf=35.0 psf (Sat roof snow); Category II; Exp C; Fully Exp.; Ct= 1
4) This truss has been designed for greater of min roof live toad of 16.0 psi or 2.00 times flat roof load of 35.0 psf on overhangs
non -concurrent with other live loads.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 2-0-0 cc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrenl with any other live loads.
B)' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) B, F except (jt=1b)
J=107, H=106.
10) Beveled plate or shim required to provide full bearing surface with truss chord atjoint(s) B, F.
11) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
o
N55
russ I ype
Oty
- -
Copper Creak lot2 blk 3 sky msado
i6-17]653
T02
Common Supported Gable
1
1
CSI.
DEFL.
in
(loc)
IIdem
L/d
Job Reference (optional)
BMC (IDAHO FALLS), IDAHO FALLS, In 83402
8.000
ma
N.b
I�
0
LUMBER-
BRACING -
TOP CHORD 2x4 OF 180OF 1.6E or 2x4 OF No.1&Btr
10-9-0
BOT CHORD 2x4 OF 180OF 1.6E or 2x4 OF No.1&Btr
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 OF Stud/Std
MiTek recommends that Stabilizers and required cross bracing
LOADING (pat)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
IIdem
L/d
PLATES GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.13
Vert(LL)
0.00
1
n/r
120
MT20 2201195
(Roof Snow=35.0)
Lumber DOL 1.15
BC 0.07
Vert(TL)
0.00
H
n/r
120
TCDL 7.0
Rep Stress Incr VES
WB 0.04
HOrz(TL)
0.00
H
n/a
n/a
BCLL 0.0
BCDL 7.0
Code IBC2012ITPJ2007
(Matrix)
Weight: 4816 FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 OF 180OF 1.6E or 2x4 OF No.1&Btr
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD 2x4 OF 180OF 1.6E or 2x4 OF No.1&Btr
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 OF Stud/Std
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. All bearings 10-9-0.
(lb) - Max Harz B=103(LC 7)
Max Uplift All uplift 10016 or less at joint(s) B, H, M, N, K, J
Max Gmv All reactions 250 Ib or less at joint(s) L, M, N. K, J except B=261 (LC 14), H=261(LC 14)
FORCES. (lb)- Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES -
1) Wind: ASCE 7-10; Vult=110mph (3 -second gust) Vasd=87mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. 11; Exp C; enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSIITPI 1.
3) TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category II; Exp C; Fully Exp.; Ct= 1
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs
non -concurrent with other live loads.
5) All plates are 1.5x4 MT20 unless otherwise indicated.
6) Gable requires continuous bottom chord bearing.
7) Gable studs spaced at 2-0-0 oc.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads.
9)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ft
between the bottom chord and any other members.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joints) B, H, M, N, K, J.
11) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) B, H.
12) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
13) "Semi-rigid pitchhreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job
Nesruse
ype
ty
y
Copper Greek loUor, 3 sky meadows
16417653
T51
Common
2
1
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 OF No.1&Btr
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 DF Stud/Std
MiTek recommends that Stabilizers and required cross bracing
Job Reference (optional)
UMI puMnV 1M11_1), iurvt' 111w. N IJJl ` uuu a Jul lb 2u16MIlercInauelnes,Inc. nu Nr'11151156
'111511562016 Pae1
ID:eGufMBF01eHO6vryu0bfx8z4LyK-B50U3u_ofoilHd W MB8nz8p8G4PhshNtAtggj_FylSDpf
-0-0-0 5-4-8 10-9-0 11-9-0
1-0-0 5-0b 5-4-8 1-0-0
0.5
LOADING (psf) SPACING- 2-0-0
TCLL 35.0 7.0 Plate Grip DOL 1.15
(Roof Snow=3 Lumber DOL 1.15
TCLL 7.0 Rep Stress Incr YES
BCDL 0.0'
BCDL 7.0 Code IBC2012ITP12007
CSI.
TC 0.28
BC 0.20
WB 0.08
(Matrix)
DEFL,
Veri(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in (loc) Ildefl L/d
-0.02 D -F >999 360
-0.04 D -F >999 240
0.01 D n/a n/a
0.02 D -F >999 240
PLATES GRIP
MT20 220/195
Weight: 40 lb FT=20%
LUMBER-
BRACING•
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF NoA&Btr
TOP CHORD
Sheathed or 6-0-0 on purlins.
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 OF No.1&Btr
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 DF Stud/Std
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (Ib/size) B=619/0-5-8 (min. 0-1-8), D=611/0-3-8 (min. 0-1-8)
Max Horz 8=103(LC 7)
Max UpliftB=-108(LC 8), D=-106(LC 9)
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD B -C=-616/97, C -D=-614/95
BOT CHORD B -F=-19/399, D -F=-19/399
NOTES -
1) Wind: ASCE 7-10; Vult=110mph (3 -second gust) Vesd=87mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cal. 11; Exp C; enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed: Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category II; Exp C; Fully Exp.; Ct- 1
3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs
non -concurrent with other live loads.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcumenl with any other live loads.
5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ft
between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joint(s) except (jl=1b) B=108,
D=108.
7) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
8) "Semi-rigid pitchbreaks with fixed heels' Member end fixity model was used in the analysis and design of this truss.
LOAD CASES) Standard
o
mss
Nes ype
y
Capper Creak lot261k 3sky meadows
16-11]653
504
Common Girder
1
L
Job Reference (optional)
BMC (IDAHO FALLS), IDAHO FALLS, ID 03402
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase= 1.15, Plate Increase= 1.15
Uniform Loads (pit)
Vert: A -D=-84, D -G=-84, B -G=-14
Concentrated Loads (lb)
Vert: H=-3997(F)J=-1296(F)K=-1471(F)
8.000s Ju1152Ul6MIIEKIndU51ae5,NC. nUNov1f1bA/:b42U16 Pae2
ID: eGufMBF01eH06wyuOb&8z4LyK-ElukeCyV7ASa2KMz3jlV303wNbwyDOZtPMzdwMyFlDph
Job
russ
Truss Type
Q y
ply
Capper Creek lot2 blk 3 sky meadows
16-117653
Set
Common Girder
1
L
Job Reference (optional)
BMC (IDAHO FALLS), IDAHO FALLS, ID 83402 8.000 s Jul 15 2016 MiTek Industries, Inc. Thu Nov 1715:1]:54 2016 Page 1
ID:eGufM8F01eH06vvyuObfx8z4LyK.ElukeGyV7ASa2KMz3jlV303wNbwyDOZtPMxdwMyl Dph
-t-0-0 3-6-0 ]-0-0 8-0-12 10-3-8 13-7-0
1.0-0 1 3-8-0 1 3-6-0 I 1.0-12 2-2-12 3-3-8
kale = 1:26.0
LOADING (psf)
TCLL 35.0
(Roof Snow=35.0)
TCDL 7.0
BCLL 0.0
BCDL 7.0
SPACING. 2-0-0
Plate Grip DOL 1.15
Lumber DOL 1.15
Rep Stress Incr NO
Code IBC2012ITP12007
CSI.
TC 0.29
BC 0.55
WB 0.39
(Matrix)
DEFL. in
Vert(LL) -0.08
Vert(TL) -0.12
Horz(TL) 0.02
Wind(LL) 0.04
(loo) I/def - L/d
G -H >999 360
G -H >999 240
G n/a n/a
G -H >999 240
PLATES GRIP
MT20 220/195
Weight:1721b FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr
TOP CHORD
Sheathed or 5-5-0 oc purlins.
BOT CHORD 2x8 DF SS
BOT CHORD
Rigid ceiling directly applied
or 10-0-0 oc bracing.
WEBS 2x4 DF Stud/Std *Except*
W2: 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr
REACTIONS. (Ib/size) G=5270/Mechanical, B=2907/0-5-8 (min. 0-1-9)
Max HorzB=122(LC 23)
Max UpliftG=-1168(LC 9), B=-766(LC 8)
FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD B -C=4573/1226, C -D=-4441/1257, D -E=-5876/1643, E -F=-61 5 811 6 6 3,
F -G=-6320/1663
BOT CHORD B -I=-1039/3710, H-1=967/3747, HJ= -130715092, J -K=1307/5092, G -K=-1307/5092
WEBS C -I=-255/168, D -I=-2271273, E -H=-1461312, D -H=-1551/5577
NOTES -
1) 2-plytruss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 -1 raw at 0-9-0 oc.
Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-2-0 oc.
Webs connected as follows: 2x4 -1 row at 0-9-0 Do.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-10; Vult=11 Omph (3 -second gust) Vasd=87mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
4) TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category Ii; Exp C; Fully Exp.; Ct= 1
5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs
non-concumentwith other live loads.
6) This truss has been designed for a 10.0 psf bottom chard live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8) Refer to girder(s) for truss to truss connections.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) except (p=1b) G=1166,
B=766.
10) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
12) Use USP HUS28 (With 16d nails into Girder & 16d nails into Truss) or equivalent at 8-0-12 from the left end to connect truss(es) PO (1
ply 2x8 DF) to front face of bottom chord.
13) Use Simpson Strong -Tie HUS26 (14-1 Od Girder, 4-1 Od Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at
10-0-12 from the left end to 12-0-12 to connect truss(es) M01 (1 ply 2x4 DF), L01 (1 ply 2x4 DF) to front face of bottom chord.
14) Fill all nail holes where hanger is in contact with lumber.
LOAD CASE(S) Standard
Continued on page 2
o
mss
Nos ype
Qty
y
Capper Creek let26lk 3 sky ...d.16-117653
603
Common
4
1
CSI.
DEFL.
in
(loc)
Ildef
L/d
Jab Reference (optional)
BMC (IDAHO FALLS), IDAHO FALLS, ID 83402 9.000s Ju1152016 MiTek Industries, Inc. I hu Nov 1715:17:52 2016 Pagel
ID: eGufM8F01eH06wyu0bfx8z4LyK-IJmzDXxlbZCsoODayli l_ZzWyoHKIZYay2SW rUylDpl
1/2"=1'
M
n'
0
Plate Offsets (X Y)— 03:0-0-0,0-0-41,
[E:0-3-1.0-1-11
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
Ildef
L/d
PLATES GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.55
Ven(LL)
-0.06
B -F
>999
360
MT20 220/195
(Roof Snow=35.0)
Lumber DOL 1.15
BC 0.36
Vert(TL)
-0.12
B -F
>999
240
TCDL 7.0
Rep Stress Incr YES
WB 0.11
Horz(TL)
0.01
E
We
n/a
BCLL 0.0
Code IBC2012/TPI2007
(Matrix)
Wind(LL)
0.06
B -F
>999
240
Weight: 54 lb FT=20%
BCDL 7.0
LUMBER -
TOP CHORD 2x4 DF 180OF 1.6E or 2x4 DF No. 1&Btr
BOT CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.i&Btr
WEBS 2x4 DF Stud/Std
SLIDER Right 2x4 OF Stud/Std 3-10-7
REACTIONS. (Ib/size) E=649/Mechanical, B=770/0-5-8 (min. 0-1-8)
Max Hom B=123(LC 5)
Max UpliftE=-95(LC 9), B=-130(LC 8)
FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD B -C=-808/130, C -D=-631/130, D -E=-8081113
BOT CHORD B -F=-42/525, E -F=-421525
WEBS C -F=0/262
BRACING -
TOP CHORD Sheathed or 5-9-2 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES -
1) Wind: ASCE 7-10; Vult=110mph (3 -second gust) Vasd=87mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category II; Exp C; Fully Exp.; Ct= 1
3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs
non -concurrent with other live loads.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrem with any other live loads.
5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tell by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 to uplift at joint(s) E except (jt=1b) B=130.
8) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSIrrPI 1.
9) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
o
FUSS
cussType
ly
y
Capper Creak loll elk 3 k meadows
i6-117fi53
502
Common Supported Gable
1
1
CSI.
DEFL.
in
_
Udell
Lid
Job Reference (optional)
uMUiIUNr1V -Hua), IUrv,U -Hua, Iu cwU[ "pw"Ul lbzolb MlaKlnduslaes, Inc. Inu NW11517512o16Pagg 1
ID:eGufM8FOleH06wyUObfx8z4LyK-g7CbOBwggG4OBse00aBoRIRRI00mO76RjOjyJ1yI pk
-1-0-0 7." 14-0-0 16-0-0
1-0-0 7-0-0 i 7-0-0 1-0-0
a
25.6
1
LUMBER- BRACING -
TOP CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.l&Btr TOP CHORD
,4-0-!
BOT CHORD 20 DF 180OF 1.6E or 2x4 DF No.1&Btr BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 DF Stud/Std
MITek recommends that Stabilizers and required cross bracing
LOADING (psf)
TCLL 35.0
SPACING- 2-0-0
CSI.
DEFL.
in
(loo)
Udell
Lid
PLATES GRIP
(Roof Snow=35.0)
Plate Grip DOL 1.15
TC 0.13
Vert(LL)
0.00
H
n/r
120
MT20 220/195
TCDL 7.0
Lumber DOL 1.15
BC 0.06
Vert(TL)
0.00
1
n/r
120
BCLL 0.0 '
Rep Stress lncr VES
WB 0.05
Horz(TL)
0.00
H
n/a
n/a
BCDL 7.0
Code IBC2012/TP12007
(Matrix)
Weight: 651b F7=20%
LUMBER- BRACING -
TOP CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.l&Btr TOP CHORD
Sheathed or 6-0-0 oc purlins.
BOT CHORD 20 DF 180OF 1.6E or 2x4 DF No.1&Btr BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 DF Stud/Std
MITek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. All bearings 14-0-0.
(lb) - Max HorzB=129(l-C 7)
Max Uplift All uplift 100 Ib or less at joints) B, H, M, K except N=-103(LC 8), J=-103(LC 9)
Max Gram All reactions 2501b or less at joint(s) B, H, L, M, K except N=269(LC 1), J=269(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES -
1) Wind: ASCE 7-10; Vult=11Omph (3 -second gust) Vasd=87mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. 11; Exp C; enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSUTPI 1.
3) TCLL: ASCE 7-10; Pf=35.0 psf (Flat roof snow); Category II; Exp C; Fully Exp.; Ct= 1
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs
non -concurrent with other live loads.
5) All plates are 1.5x4 MT20 unless otherwise indicated.
6) Gable requires continuous bottom chord bearing.
7) Gable studs spaced at 2-0-0 oc.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3.6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) B, H, M, K except
(jt=1b) N=103, J=103.
11) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSUTPI 1.
12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASES) Standard
o
toss
mss ype
ty
y
Copper Creek loll bilk 3 sky meadows
16-117653
501
Common
1
1
CSI.
DEFL.
in
(loc)/def]
Ud
Job Reference (optional)
BMC (IDAHO FALLS), IDAHO FALLS, ID 83402
5.6
Plate Offsets (X,Y)- tB:0-0-0.0-041.
(D:Edg%0-041
LOADING (pat)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)/def]
Ud
PLATES GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.53
Vert(LL)
-0.06
D -F
>999
360
MT20 220/195
(Roof Snow=35.0)
Lumber DOL 1.15
BC 0.36
Vert(TL)
-0.12
D -F
>999
240
TCDL 7.0
BCLL 0.0 '
Rep Stress Incr YES
WE 0.11
Horz(TL)
0.01
D
We
We
BCDL 7.0
Code IBC2012/TPI2007
(Matrix)
Wind(LL)
0.06
B -F
>999
240
Weight: 51 to FT=20%
LUMBER -
TOP CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.l&Btr
BOT CHORD 2x4 DF 1800E 1.6E or 2x4 DF No.l&Btr
WEBS 2x4 DF Stud/Std
REACTIONS. (Ib/size) B=774/05-8 (min. 0-1-8), D=774/0 -5-B (min. 0-1-8)
Max Horz B=-129(LC 6)
Max UpliftB=-131(LC 8), D=-131 (LC 9)
FORCES. (Ib) -Max. Comp./Max. Ten. -Al forces 250 (lb) or less except when shown.
TOP CHORD B -C=-820/129, C -D=-8201129
BOT CHORD B -F=-32/537, D -F=-32/537
WEBS C -F=0/276
BRACING -
TOP CHORD Sheathed or 5-9-9 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES -
1) Wind: ASCE 7-10; Vult=110mph (3 -second gust) Vasd=87mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category II; Exp C; Fully Exp.; Ct= 1
3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs
non -concurrent with other live loads.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joints) except Qt=lb) B=131,
D=131.
7) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSUTPI 1.
8) "Seml-dgid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job
russ
I russ I ype
ty
y
Capper Creek loll blk 3 sky meadows
16-117653
Q01
Monopitch
13
1
TCLL 35.0
SPACING-
2-0-0
C51.
DEFL.
in
Job Reference (optional)
amu (luanU -ALua), ioAnU -Alla, w UJ402 8,000 s Jul 15 2016 MiTek Industries, Inc. Thu Nov 1715:17:48 2016 Pae 1
ID:eGufM8FOleHQ6vvyu0bfx8z4LyK-QYXSNgunXLhRKPvpjSe5p7pt3Avcpku_1 QUIIiyl1Vpn
-1-o-0 6-0-0 8-0-0
1-0.0 6-0-0 2-0-0
Scale =1:31.1
8-0-0
LOADING (psf)
BRACING -
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
TOP CHORD
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No. 1&Btr
BOT CHORD
WEBS 2x4 DF Stud/Std
REACTIONS. (Ib/size) D=-33/Mechanical, B=496/0-5-8 (min. 0-1-8), E=402/Mechanical
Max Horz B=221 (LC 8)
TCLL 35.0
SPACING-
2-0-0
C51.
DEFL.
in
floc)
I/deft
Ud
PLATES
GRIP
(Roof Snow=35.0)
Plate Grip DOL
1.15
TC 0.35
Vert(LL)
-0.18
B-E
>505
360
MT20
220/195
TCDL 7.0
Lumber DOL
1.15
BC 0.41
Vert(TL)
-0.37
B-E
>246
240
BCLL 0.0
Rep Stress Incr
YES
WE 0.15
Horz(TL)
-0.00
D
rile
Na
BCDL 7.0
Code IBC2012lTP12007
(Matdx)
Wind(LL)
0.00
B
-*
240
Weight: 32 lb
FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
TOP CHORD
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No. 1&Btr
BOT CHORD
WEBS 2x4 DF Stud/Std
REACTIONS. (Ib/size) D=-33/Mechanical, B=496/0-5-8 (min. 0-1-8), E=402/Mechanical
Max Horz B=221 (LC 8)
Max UpllftD=-34(LC 16), B=-44(LC 8), E=-168(LC 8)
Max Grav D=23(LC 8), B=496(LC 1), E=402(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOPCHORD B -C=-331/0
WEBS C -E=-389/224
Sheathed or 6-0.0 oc purlins.
Rigld ceiling directly applied or 10-0-0 oc bracing
MiTek recommends that Stabilizers and required cross bracing
e installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES -
1) Wind: ASCE 7-10; Vult=110mph (3 -second gust) Vasd=87mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. 11; Exp C; enclosed; MWFRS
(envelope) gable and zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category 11; Exp C; Fully Exp.; Ct= 1
3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs
non -concurrent with other live loads.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 No uplift at joint(s) D, 8 except at -lb)
E=168.
8) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/rPI 1.
9) "Semi-rigid pitchbreaks with fixed heels' Member end flxily model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
o
MISS
I NSS I ype
Qty
Ply
CaPPer Creek lot2 blk3 sky meatlows
16-11]653
P01
Roof Special GUtler
1
1
Jab Reference (optional)
nmc p�nnv rsLw), ionnv rnua, i�o—< ID:eGufM8F0leHQ6wyu0bfx8z4LyK-T9PizTSX?jRj451Rb1 cdk1 RSNB-LeEhZ6?Begyll pp
NOTES -
15) Fill all nail holes where hanger is in contact with lumber.
16) "NAILED" indicates 3-10d (0.148'x3") or 3-12d (0.148'x3.25`) toe -nails. For more details refer to MiTelks ST -TOENAIL Detail.
17) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A -E=-84, E -F=-84, G -L=-14
Concentrated Loads (Ib)
Vert: B=19(B) K=-388(8) H=-388(8) E=1 9(B) M=16(B) N=1 9(B) 0=19(B) P=19(B) Q=19(6) R=19(13) 5=19(B) T=19(B) U=19(B) V=19(B) W=1 9(B) X=-391(8) Y=-388(8)
Z=-388(8) AA= -388(B) AB= -388(8) AC= -388(8) AD= -388(B) AE= -388(B) AF= -388(B) AG= -388(B) AH= -388(B)
o, y,. ,,..,.. iuL, ,m,..—L—, iu ua-,uc
NAILED
NAILED NAILED NAILED NAILED NAILED NAILED
6.00 Ll2 Scale =1:41.0
NAILED
NAILED NAILED NAILED NAILED NAILED
mss
rU33 ypeQty
P
y
Capper Creek lot2 Nk 3 sky meadows
16-71]653
P,
POi
Roof Special Girder
1
1
W
t
r
(loo)
/deb
L/d
Jab Reference (optional)
o, y,. ,,..,.. iuL, ,m,..—L—, iu ua-,uc
NAILED
NAILED NAILED NAILED NAILED NAILED NAILED
6.00 Ll2 Scale =1:41.0
NAILED
NAILED NAILED NAILED NAILED NAILED
L X Y Z K AA AB J AC ADAE AF I AG AH H G
LUS24 LUS24 LUS24 LUS24 LUS24 LUS24 LUS24 LUS24 LUS24 LUS24 LUS24
LUS24 LUS24
5-5-2 10 -it -15 16-6-13 27-77-15 2&68
F5-7 111 e_6dd
Plate Offsets (X,Y)– lc:0-5-0,0-4-81, fGEdge,0-5-81 [J:0-5-8,0-6-0],
M N
O B
P
Q
R
S T
U
U
V
SPACING- 2-0-0
W
t
r
(loo)
/deb
L/d
PLATES
GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.71
Vert(LL)
-0.18
I.J
>999
360
MT20
220/195
(Roof Snow=35.0)
Lumber DOL 1.15
BC 0.55
Vert(TQ
-0.25
I -J
>999
240
MT20HS
165/146
TCDL 7.0
Rep Stress Incr NO
WB 0.93
Horz(TL)
0.05
G
W6
n/a
BCLL 0.0
Code IBC2012rrP12007
(Matrix)
Wind(LL)
0.11
I -J
>999
240
W1
FT=20%
BCDL 7.0
at
—nn
nn
flu
Lull
nn
nri
L X Y Z K AA AB J AC ADAE AF I AG AH H G
LUS24 LUS24 LUS24 LUS24 LUS24 LUS24 LUS24 LUS24 LUS24 LUS24 LUS24
LUS24 LUS24
5-5-2 10 -it -15 16-6-13 27-77-15 2&68
F5-7 111 e_6dd
Plate Offsets (X,Y)– lc:0-5-0,0-4-81, fGEdge,0-5-81 [J:0-5-8,0-6-0],
(LEdge 0-5-121
TOP CHORD
Sheathed or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc
purlins (3-7-10 max.): A-E.
BOT CHORD
Rigid ceiling directly applied or 7-10.9 oc bracing.
WEBS
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loo)
/deb
L/d
PLATES
GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.71
Vert(LL)
-0.18
I.J
>999
360
MT20
220/195
(Roof Snow=35.0)
Lumber DOL 1.15
BC 0.55
Vert(TQ
-0.25
I -J
>999
240
MT20HS
165/146
TCDL 7.0
Rep Stress Incr NO
WB 0.93
Horz(TL)
0.05
G
n/a
n/a
BCLL 0.0
Code IBC2012rrP12007
(Matrix)
Wind(LL)
0.11
I -J
>999
240
Weight: 202 lb
FT=20%
BCDL 7.0
LUMBER -
TOP CHORD 2x6 DF 1800F 1.6E or 20 DF SS *Except*
T2: 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr
BOT CHORD 2x8 DF SS
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr *Except*
W7,W4: 2x6 OF 180OF 1.6E or 2x6 DF SS, W5,W2: 2x4 OF Stud/Std
REACTIONS. (Ib/size) L=3642/Mechanical, G=3413/Mechanical
Max Hoa L=-17(LC 11)
Max UpliftL=-1531(LC 6), G=l399(LC 6)
Max GravL=4372(LC 24), G=4011(LC 24)
BRACING -
TOP CHORD
Sheathed or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc
purlins (3-7-10 max.): A-E.
BOT CHORD
Rigid ceiling directly applied or 7-10.9 oc bracing.
WEBS
1 Row at midpt B -L, D -H
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation gulde.
FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD A -L=-322/90, B -P=-5055/1770, P -Q=-505511770, C -Q=-5055/1770, C -R=-5055/1770,
R -S=-5055/1770, S -T=-5055/1770, T -U=-505511770, D -U=-5055/1770, D -V=-852/303,
V -W=-843/303, E -W=-842/303, E -F=-926/331, F.G=-3641/1279
BOT CHORD L -X=1265/3624, X -Y=-126513624, Y -Z=-1265/3624, K -Z=-1265/3624, K -AA= -1265/3624,
AA -AB= -1265/3624, J -AB= -1265/3624, J -AC= -1462/4205, AC -AD= -1462/4205,
AD -AE= -1462/4205, AE -AF= -1462/4205, I -AF= -1462/4205, I -AG= -1462/4205,
AG -AH= -1462/4205, H -AH= -1462/4205
WEBS B -L=-494011730, B -K=-542/1377, BJ= -67511927, C -J=-725/197, D -J=-00711145,
D -I=-556/1422, D -H=452711576, F -H=-1165/3349
NOTES -
1) Wind: ASCE 7-10; Vult=110mph (3 -second gust) Vasd=87mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cal. 11; Exp C; enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=35.0 psf (Flat roof snow); Category II; Exp C; Fully Exp.; Ct= 1
3) Unbalanced snow loads have been considered for this design.
4) Provide adequate drainage to prevent water ponding.
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrentwith any other live loads.
7) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8) Refer to girder(s) for tress to truss connections.
9) Provide metal plate or equivalent at bearing(s) L, G to support reaction shown.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joint(s) except Qt=1b) L=1531
, G=1399.
11) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
14) Use Simpson Strong -Tie LUS24 (4-1 Cd Girder, 2-1 Od Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at 0.9-4
from the left en�tto 21-11-3 to connect iruss(es) 401 (1 ply 2x4 DF) to back face of bottom chord
Continued on page
Job
russ
I russ I ype
aty
yCapper
Greek 1oQ1,1k 3k meadows
16-117653
N04
Common Girder
1
2
Job Reference a llonal
BMC (IDAHO FALLS), IDAHO FALLS, ID 83,102
8.000 s Jul 152016 MiTek loduslnes, Inc. Thu Nov 1715: 17: 362016 Pa e2
ID:eGufM8FOleHG6wyu0bfx8z4LyK-mEows2kFMfB8uZ_WOxOHKbJiULkf?9?DGZagH PylIfix
NOTES -
15) Use Simpson Strong -Tie HTU210 (32-10d Girder, 32-10dxl 1/2 Truss) or equivalent at 8-0-12 from the left end to connect tmss(es) PO1 (1 ply 2x8 DF) to back face of bottom
chord.
16) Use Simpson Strong -Tie HUS26 (14-1 Od Girder, 4-10d Truss, Single Ply Girder) or equivalent spaced at 2-6-0 oc max. starting at 10-0-12 from the left end to 16-5-4 to
connect truss(es) M01 (1 ply 2x4 DF), L01 (1 ply 2x4 DF), E03 (1 ply 2x4 DF), E01 (1 ply 2x4 DF) to back face of bottom chord.
17) Use Simpson Strong -Tie HGUS210-2 (46-10d Girder, 16-10d Truss) or equivalent at 13-8-8 from the left end to connect truss(es) H01 (2 ply 2x8 DF) to back face of bottom
chord.
18) Use USP HUS28 (With 16d nails into Girder 8 16d nails into Truss) or equivalent at 18-54 from the left end to connect truss(es) E01 (1 ply 2x4 DF) to back face of bottom
chord.
19) Fill all nail holes where hanger is in contact with lumber.
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase= 1. 15, Plate Increase= 1. 15
Uniform Loads (plf)
Vert: A -E=-84, E -H=-84, B -H=-14
Concentrated Loads (lb)
Vert: L= -1335(B) M=-4358(8) K= -4226(B) 0=-1584(B) P=-1570(B)Q=-1567(B) R=-1567(8)
Job
mssmss
Type
Qty
ply
Coppsr Greek lo@ blk 3 sky meadows
16-117653
N04
Common Girder
1
CSI.
DEFL.
in
(loo)
I/dell
L
Joh Reference (optional)
BMC (IDAHO FALLS), IDAHO FALLS, ID 03902 8,000 a Jul 152016 MiTek Indumnes, Inc. Thc Nov 171517:36 2016 Pagge 1
ID:erufMBF01eHQ6wyuObfx8z4LyK-mEows2kFMfB8uZ-WGxQHKbJIULkf797DGZagHPyI pz
1-0-0 60-0 8-0-12 10-0-0 13 -e -e t6 -PO 79-70-0
7-0-0 5-0-0 3-0-12 1-11-4 3-8-8 2J-8 3-70-0
�l
HTU210 HUS26 HUS26 HGUS210-2 HUS26 HUS28
HUS26
60-0 8-0-12 160-0 13-8-8 16 -OA 19-10-0
60-0 1 3-0-12 1-11-4 3-8-8 2-3-8 3-10-0
Scale =1:38.9
m ]7
79
Plate Offsets (X,Y)- tB:0J-5,Edge1.
fH:Edge,0.2-131. (J:0-4-4,04-81.
(K:0-3-8.0-8-01.
(L:0-7-12,04-01.
fM:0-3-8.0-4-121
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loo)
I/dell
L/d
PLATES
GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.83
Verl(LL)
-0.23
K -L
>999
360
MT20
220/195
(Roof Snow=35.0)
Lumber DOL 1.15
BC 0.74
Vert(TL)
-0.32
K -L
>723
240
MT20HS
165/146
TCDL 7.0
Rep Stress Incr NO
WB 0.78
Horz(TL)
0.06
H
We
n/a
MT18H
220/195
BCLL 0.0
Code IBC2012ffP12007
(Matrix)
Wind(LL)
0.10
M
>999
240
Weight:3071b
FT=20%
BCDL 7.0
LUMBER- BRACING -
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr TOP CHORD Sheathed or 2-5-14 oc purlins.
BOT CHORD 2x10 DF SS BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 DF Stud/Std "Except`
W1,W6: 2x4 OF 180OF 1.6E or 2x4 DF No.1&Btr
REACTIONS. (Ib/size) H=11196/0-3-8 (req. 0-6-0), B=703110-5-8 (min. 0-3-12)
Max Hoe B=169(LC 21)
Max Up1iftH=-1937(LC 9), B=-1533(LC 8)
FORCES. (Ib) - Max. CompdMax. Ten. -AII forces 250 (lb) or less except when shown.
TOP CHORD B -C=-1169812543, C -D=-1140012486, D -E=-10396/2175, E -F=-10487/2182, F -G=-15107/2736,
G -H=-16364/2674
BOT CHORD B -N=-2157/9671, M -N=-2157/9671, L -M=-1995/9387, L -O=-2188/12538, K -O=-2188112536,
K -P=-2328/13517, J -P= -2328/13517,1 -J= -2328/13517,1-Q=-2328/13517, Q -R=-2328113517.
H -R=-2326113517
WEBS E -L=-2320/11114, G -I=-211/1557, D -M=-925/2365, C -M=4071232, D -L=-1972/835,
F -K=-835/6511, F -L=5654/814, G -K=-14411259
NOTES -
1) 2-plytruss to be connected togetherwith 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 -1 row at 0-4-0 oc.
Bottom chords connected as follows: 2x10 - 2 rows staggered at 0-2-0 Do.
Webs connected as follows: 2x4 -1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-10; Vull=7lomph (3 -second gust) Vasd=87mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
4) TCLL: ASCE 7-10; Pf=35.0 psf (Flat roof snow); Category Il; Exp C; Fully Exp.; Ct= 1
5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs
non -concurrent with other live loads.
6) All plates are MT20 plates unless otherwise Indicated.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8)' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9) WARNING: Required bearing size at joint(s) H greater than input bearing size.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) except (jl=1b) H=1937
, B=1533.
11) Beveled plate or shim required to provide full bearing surface with truss chord atjoint(s) H.
12) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
13) "Semi-rigid pitchbreaks with fixed heels" Member and fixity model was used in the analysis and design of this truss.
14) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n.
Continued on page 2
o
mss
russ ype
ty
y
Dapper Greek lot261k3sky meadans
i6-11]653
NO3
Common Stmctuml Gable
1
1
CSI.
DEFL.
in
(10c)
I/deft
Ud
Job Reference o tional
BMC (IDAHO FALLS), IDAHO FALLS, ID 03402 8.000 s Jul 152016 MiTek Industries, Inc. Thu Nov 1715:17:34 2016 Page 1
ID:eGufM8F01eHO6vvyuObfx8z4LyK-gshARNj?g1wl]eFr7uWOpFAEVDX8zXKjwpF5ZDWyI q?
-1-0-0 5-0-0 10 -OA 15-0.0 20-0-0
1-0-0 5-0-0 5-0-0 5-0-0 5-0-0
a,
10.0-0
3 = 1:34.3
to �
d
Plate Offsets (X,Y)- (B:0-2-7.0-2-11.
1F:0-2-7.0-2-11
TOP CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr TOP CHORD
Sheathed or 6-0-0 oc purlins.
BOT CHORD 2x4 OF 1800F 1.6E or 2x4 OF No.1&Btr BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 OF Stud/Std
MiTek recommends that Stabilizers and required cross bracing
OTHERS 2x4 OF Stud/Std
LOADING (psf)
SPACING. 2-0-0
CSI.
DEFL.
in
(10c)
I/deft
Ud
PLATES GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.31
Vert(LL)
-0.16
F -G
>729
360
MT20 220/195
(Roof Snow=35.0)
Lumber DOL 1.15
BC 0.37
Vert(TL)
-0.34
F -G
>346
240
TCDL 7.0
Rep Stress Incr YES
WB 0.45
Hoa(TL)
0.01
F
Fie
Fila
BCLL 0.0
Code IBC2012rrP12007
(Matrix)
Wind(LL)
0.03
F -G
>999
240
Weight:120lb FT=20%
BCDL 7.0
LUMBER- BRACING -
TOP CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr TOP CHORD
Sheathed or 6-0-0 oc purlins.
BOT CHORD 2x4 OF 1800F 1.6E or 2x4 OF No.1&Btr BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 OF Stud/Std
MiTek recommends that Stabilizers and required cross bracing
OTHERS 2x4 OF Stud/Std
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. All bearings 10-5-8 except at --length) F=0-5-8.
(Ib) - Max Hoa B=171(LC 7)
Max Uplift All uplift 1001b or less atjoint(s) F, B, K except G=-194(LC B), H=-143(LC 3)
Max Grav All reactions 250 lb or less atjoint(s) I, J, K except F=366(LC 1), B=389(LC 1),
G=1192(LC 1), G=1192(LC
1)
FORCES. (Ib) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD B -C=-369/76, C-13=44/264, D -E=-6/261, E -F=-350/93
BOT CHORD B -K=-1201273, J -K= -1201273.1-J=-1201273, H-1=-1 2 012 7 3, G -H=-120/273
WEBS D -G=-557/104, E -G=-4361221, C -G=-014/229
NOTES -
1) Wind: ASCE 7-10; Vult=110mph (3 -second gust) Vasd=B7mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-10; Pf=35.0 psf (net roof snow); Category 11; Exp C; Fully Exp.; Ct= 1
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs
non -concurrent with other live loads.
5) All plates are 1.5x4 MT20 unless otherwise indicated.
6) Gable studs spaced at 2-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ft
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) F, B, K except Ql=1b)
G=194, H=143.
10) Beveled plate or shim required to provide full bearing surface with truss chord atjoint(s) F.
11) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
13) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in.
LOAD CASE(S) Standard
Job
may
I russ I ype
Uty
Hly
Copper Creak loll blk 3 Ay meadows
16-117663
NO2
Common SuppOned Gable
1
1
TC 0.13
Vert(LL)
0.00
M
n/r
120
Job Reference (optional)
dnl
d
v , a n u r u N
ra.0
O
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loo)
I/dell
Ud
PLATES GRIP
TCLL 35.0
(Roof Snow=35.0)
Plate Grip DOL 1.15
TC 0.13
Vert(LL)
0.00
M
n/r
120
MT20 220/195
TCDL 7.0
Lumber DOL 1.15
BC 0.07
Vert(TL)
0.00
M
n/r
120
BCLL 0.0
Rep Stress [nor YES
WB 0.12
Horz(TL)
0.00
L
n/a
n/a
BCDL 7.0
Code IBC20121TPI2007
(Matrix)
Weight: 106 lb FT=20%
LUMBER -
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.i&Btr
OTHERS 2x4 OF Stud/Std
BRACING-
TOPCHORD
BOTCHORD
REACTIONS. All bearings 20-0-0.
(lb) - Max Horz B=-177(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) B, S, T, U, V, Q, P. O, N, L
Max Grav All reactions 250 lb or less at joints) B, R, 5, T, U, V, Q, P, O, N, L
FORCES. (Ih) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
Sheathed or 6-0-0 oc purlins.
Rigid ceiling directly applied or 10-0-0 oc bracing
M'Tek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installationguide.
NOTES -
1) Wind: ASCE 7-10; Vuh=110mph (3 -second gust) Vasd=B7mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS
(envelope) gable end zone; cantilever left and night exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSVTPI 1.
3) TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category 11; Exp C; Fully Exp.; Ct= 1
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs
non -concurrent with other live loads.
5) All plates are 1.5x4 MT20 unless otherwise indicated.
6) Gable requires continuous bottom chord bearing.
7) Gable studs spaced at 2-0-0 oc.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ft
between the bottom chord and any other members.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 10016 uplift at joint(s) B, S, T, U, V, Q, P, O
, N, L.
11) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASES) Standard
Job
HISS
TrussType
ly
Ply
Capper Creek lot? 61k3sky meadows
16-177653
N01
Common
2
1
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
Job Reference (optiona0
BMC (IDAHO FALLS), IDAHO FALLS, ID 93402
a
= 1:34.3
Plate Offsets (X Y)- [B:0-2-7,0-2-11,
F:0-2-7.0-2-111, [G:04-0,0-3-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
I/deft
Ud
PLATES GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.30
Vert(LL)
-0.14
F -G
>999
360
MT20 220/195
(Roof Snow=35.0)
Lumber DOL 1.15
BC 0.47
Vert(TL)
-0.31
F -G
>747
240
TCDL 7.0
Rep Stress ]nor YES
WB 0.26
HOrz(TL)
0.03
F
n/a
n/a
BCLL 0.0
Code IBC2012frPI2007
(Matrix)
Wind(LL)
0.04
F -G
>999
240
Weight: 861b FT=20%
BCDL 7.0
LUMBER -
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Bir
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.l&Btr
WEBS 2x4 DF Stud/Std
REACTIONS. (Ib/size) F=954/0-5.8 (min. 0-1-8), B=1071/0-5-8 (min. 0-1-8)
Max Horz B=171(LC 5)
Max UpliftF=-142(LC 9), B=-175(LC 8)
FORCES. (lb) -Max. Comp./Max. Ten. -All fomes 250 (Ib) or less except when shown.
TOP CHORD B -C=-1379/217, C -D=-1005/187, D -E=1007/185, E -F=-1363/221
BOT CHORD B -G=-216/1050, F -G=-115/1061
WEBS D -G=-81/582, E -G=-396/217, C -G=-383/212
BRACING -
TOP CHORD Sheathed or 5-5-3 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
installation guide.
NOTES -
1) Wind: ASCE 7-10; Vult=110mph (3 -second gust) Vasd=87mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS
(envelope) gable end zone; cantilever left and night exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category 11; Exp C; Fully Exp.; Ct= 1
3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs
non -concurrent with other live loads.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ft
between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) except (jt=lb) F=142,
B=175.
7) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) F.
8) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSIfrPI 1.
9) "Semi.dgid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
10) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in.
LOAD CASE(S) Standard
Job
mss
I msS I ype
Oty
Ply
Capper Greek lat2 blk 3 sky meadows
16-117653
M01
Hip
1
1
MiTek recommends that Stabilizers and required cross bracing
LOADING (psf)
SPACING-
2-0-0
CSI.
REACTIONS. (Ib/size) K=1135/Mechanical, G=1135/Mechanical
Jab Reference (optional)
BMC (IDAHO FALLS), IDAHO FALLS, ID 83402
MiTek Indusltles. Inc. Thu
Scale = 1:38.0
8-1-1 13-8-819-3-15 23-5-8
8 7 1 5-7-1 5 7 7 4 15
Plate Offsets (X,Y)— 11:0-3-0,0-3-01
TOP CHORD 2x4 OF 1800F 1.6E or 2x4 OF No.i&Btr TOP CHORD
Sheathed or 5-10-8 oc purlins, except end verticals, and 2-0-0 oc
BOT CHORD 2x4 OF 1800F 1.6E or 2x4 OF No.i&Btr
purlins (5-6-0 max.): C -E.
WEBS 2x4 OF Stud/Std "Except* BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
W2: 2x4 OF 1800F 1.6E or 2x4 OF No.1&Btr WEBS
1 Row at midpt D -J, D -H
MiTek recommends that Stabilizers and required cross bracing
LOADING (psf)
SPACING-
2-0-0
CSI.
REACTIONS. (Ib/size) K=1135/Mechanical, G=1135/Mechanical
DEFL.
in
(loc)
I/dell
Ud
PLATES
GRIP
TCLL 35.0
Plate Grip DOL
1.15
TC
0.70
Vert(LL)
-0.09
J -K
>999
360
MT20
220/195
(Roof Snow=35.0)
Lumber DOL
1.15
BC
0.28
Vert(TL)
-0.19
J -K
>999
240
TCDL 7.0
Rep Stress Incr
YES
WB
0.87
Horz(TL)
0.04
G
n/a
n/a
BCLL 0.0"
Code IBC2012/TP12007
(Matrix)
Wind(LL)
0.02
1
>999
240
Weight:1471b
FT=20%
BCDL 7.0
LUMBER- BRACING -
TOP CHORD 2x4 OF 1800F 1.6E or 2x4 OF No.i&Btr TOP CHORD
Sheathed or 5-10-8 oc purlins, except end verticals, and 2-0-0 oc
BOT CHORD 2x4 OF 1800F 1.6E or 2x4 OF No.i&Btr
purlins (5-6-0 max.): C -E.
WEBS 2x4 OF Stud/Std "Except* BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
W2: 2x4 OF 1800F 1.6E or 2x4 OF No.1&Btr WEBS
1 Row at midpt D -J, D -H
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (Ib/size) K=1135/Mechanical, G=1135/Mechanical
Max HorzK=105(LC 10)
Max UpliftK=-138(LC 10), G=-147(LC 6)
Max GravK=1349(LC 28), G=1310(LC 27)
FORCES. (lb) - Max. Comp./Max. Ten. -All fomes 250 (Ib) or less except when shown.
TOP CHORD B -C=-1236/177, C -L=-10911175, D -L=-1097/174, D -M=-736/117, E -M=-731/118, E -F=-827/11 1,
F -G=-1288/157
BOT CHORD J -K=-192/891, J -N=18411376, 1-N=-184/1376, 1-0=-184/1376, H-0=-184/1376
WEBS B -J=-00/436, DJ= -434/91, D -H=-9811153, B -K=-1352/154, F -H=-131/1152
NOTES -
1) Wind: ASCE 7-10; Vult=110mph (3 -second gust) Vasd=87mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. 11; Exp C; enclosed; MW FRS
(envelope) gable end zone; cantilever left and night exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=35.0 pat (Flat roof snow); Category Il; Exp C; Fully Exp.; Ct= 1
3) Unbalanced snow loads have been considered for this design.
4) Provide adequate drainage to prevent water ponding.
5) This truss has been designed for a 10.0 lost bottom chord live load nonconcurrent with any other live loads.
6)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.Opsf.
7) Refer to girders) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) except (jt=1b) K=138,
G=147.
9) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
o
NesI
was I ype
DEFL.
y
Copper Creek lvl2 blk3 sky meadows
16-11]653
LG01
GABLE
1
1
Ver( CIL)
n/a -
We
999
MT20 220/195
(Roof Snow=35.0)
Job Reference o tional
BMC (IDAHO FALLS), IUAHO CALLS, IU tltl9U[ nuwsdunnzmn moan msusmes, mc. v' -r'[r '2ra el
ID:eGufM8F0leHQ6vvyu0bfx8z4LyK-XVI Wz_dCUu2PIAon_YmAThRMSjghOF6uCf000y81346
8-2-5 164-10
8-2-5 8-2-5
LK
Scale = 1:33.5
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
Wall
Ud
PLATES GRIP
TCLL 35.0
Plate Grp DOL 1.15
TC 0.04
Ver( CIL)
n/a -
We
999
MT20 220/195
(Roof Snow=35.0)
Lumber DOL 1.15
BC 0.03
Vert(TL)
n/a -
Fila
999
TCDL 7.0
Rep Stress Incr YES
WB 0.12
Horz(TL)
0.00 1
Fila
n/a
CLL 0.0"
Bnm vn
Code IBC20121TP12007
(Matrix)
Weight: 86 lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr TOP CHORD
Sheathed or 6-0-0 oc purlins.
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 DF Stud/Std
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. All bearings 16-4-10.
(Ib) - Max Horz A=-168(LC 4)
Max Uplift All uplift 100lb or less at joint(s) A, I except 0=-104(LC 8), P=-101(LC 8), Q=-108(LC
8), M=103(LC 9),
K=-102(LC 9), J=-108(LC 9)
Max Grav All reactions 250 ib or less at joint($) A, I, N, O, P, Q. M, K, J
FORCES. (ib) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
NOTES -
1) Wind: ASCE 7-10; Vu1t=110mph (3 -second gust) Vasd=87mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. 11; Exp C; enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=35.0 psf (Oat roof snow); Category 11; Exp C; Fully Exp.; Ct= 1
3) All plates are 1.5x4 MT20 unless otherwise indicated.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live leads.
6)"This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-(-0 wide will fit
between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) A, I except (jt=1b)
0=104, P=101, Q=108, M=103, K=102, J=108.
B) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSUTPI 1.
9) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job
russ
I russ I ype
ly
yCapper
Creek loll blk 3 sky meadows
16-117653
L01
Hip
1
1
Sheathed or 4-9-5 oc purlins, except end verticals, and 2-0-0 oc
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.i&Btr
purlins (4-0-8 max.): C -D.
WEBS 2x4 DF Stud/Std *Except
BOT CHORD
Job Reference (optional)
BMC (IDAHO FALLS), IDAHO FALLS, ID 83402
8.000
Inc.
LOADING (psf)
TCLL 35,0 7.0
(Roof Snow=3
TCDL 7.0
BCLL 0.0'
BCDL 7.0
SPACING- 2-0-0
Plate Grip DOL 1.15
Lumber DOL 1.15
Rep Stress Incr YES
Code IBC2012/TPI2007
CSI.
TC 0.84
BC 0.27
WB 0.59
(Matrix)
DEFL. in (loc)/deft L/d
Vert(LL) -0.05 IJ >999 360
Vert(TL) -0.10 J -K >999 240
Hom(TL) 0.03 G n/a n/a
Wind(LL) 0.01 1 >999 240
PLATES GRIP
MT20 220/195
Weight:1531b FT=20%u
LUMBER-
BRACING -
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
TOP CHORD
Sheathed or 4-9-5 oc purlins, except end verticals, and 2-0-0 oc
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.i&Btr
purlins (4-0-8 max.): C -D.
WEBS 2x4 DF Stud/Std *Except
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
W20104: 2x4 DF 1800E 1.6E or 2x4 DF No.t&Btr
WEBS
1 Row at midpt D -J, B -K
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (Ib/size) K=1135/Mechanical, G=11351Mechanical
Max HorzK=-126(LC 11)
Max UpliftK=-135(LC 10), G=-157(LC 11)
Max GravK=1485(LC 28), G=1598(LC 28)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD B -L=-1009/137, C -L=-815/142, C -M=-796/152, D -M=-798/152, D -E=-1321/182, E -N=-1210/161,
F -N=-1522/150, F -G=-1560/174
BOT CHORD K-0=65/639, O -P=-65/639, J -P=-65/639, J-0=45/1001, I -Q=45/1001,
H -I=-94/1232
WEBS B -J=54/539, DJ= -358/100, D-1=49/330, E -I=-324/208, E -H=-553/93, B
-K=-1394/131,
F -H=-96/1333
NOTES -
1) Wind: ASCE 7-10; Vult=110mph (3 -second gust) Vasd=87mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. 11; Exp C; enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category 11; Exp C; Fully Exp.; Ct= 1
3) Unbalanced snow loads have been considered for this design.
4) Provide adequate drainage to prevent water ponding.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.Opsf.
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) except (jt=1b) K=135,
G=157.
9) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/FPI 1.
10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
11) Graphical puriin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
Job
russuss
I ype
aty
Ply
Copper Creek loll blk3 sky meadows
16-117653
K01
Roof Special
1
1
Job Reference o ti0nal
BMC (IDAHO FALLS), IDAHO FALLS, ID 83402
C.UUVSJUIIJCVIVMIIeKlneueln¢S,IIIG mU NOV 1/lO:l/:L:f LVIV Yaee¢L
ID:eGufM8F01eHQ6vvyuObfx&4LyK-fk WOBca5QfY_gZVOlihElrHeL5QmSPkJH 1 xULyIDgA
NOTES -
16) Use Simpson Strong -Tie LUS24 (4-10d Girder, 2-10d Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at 19-0-12 from the left end to 23-0-12 to
connect truss(es) J01 (1 ply 2x4 DF) to back face of bottom chord.
17) Fill all nail holes where hanger Is in contact with lumber.
18) Hanger(s) or other connection devices) shall be provided sufficient to support concentrated load(s) 61 Ib down and 42 lb up at 17-0-12 on bottom chord. The
design/selection of such connection device(s) is the responsibility of others.
19) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead+ Snow (balanced): Lumber Increase=1.15, Plate Increase= 1. 15
Uniform Loads (plf)
Vert: A -K=-84, K -Q=-84, B -R=-14
Concentrated Loads (lb)
Vert: AE= -61 AF= -554(8) AG= -554(8) AH= -554(8)
0
Truss
russ ype
Qty
Ply
Copper Creek loft blk 3 sky meadows
6-117653
1710-1
K01
Roof Special
1
1
MT20 2201195
(Roof Snow=35.0)
Lumber DOL 1.15
BC 0.22
Vert(TL)
0.00 A n/r 120
Job Reference (optional)
BMC (IDAHO FALLS), IDAHO FALLS, ID 83402
AD AC AB AA Z Y X WV AE U AF T AG S AH R
LU824 LUS24 LUS24
1:43.7
LOADING (Pat)
SPACING- 2-0-0
CSI.
DEFL.
in floc) I/defl L/d
PLATES GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.22
Vert(LL)
0.00 A n/r 120
MT20 2201195
(Roof Snow=35.0)
Lumber DOL 1.15
BC 0.22
Vert(TL)
0.00 A n/r 120
TCDL 7.0
Rep Stress Incr NO
WB 0.27
Horz(TL)
0.00 R n/a n/a
BCLL 0.0
Code IBC2012(rPI2007
(Matrix)
Weight: 173 lb FT=20%
BCDL 7.0
LUMBER-
BRACING -
TOP CHORD 2x4 DF 180OF 1.6E or 2x4 DF N0.1&Btr
TOP CHORD
Sheathed or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc
BOT CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr
purlins (6-0-0 max.): K -Q.
WEBS 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 OF 1800F 1.6E or 2x4 DF No.1&Btr *Except*
WEBS
1 Row at midpt Q -R
ST6,ST5,ST4,ST3,ST2,ST1: 2x4 DF Stud/Std
_
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. All bearings 25-0-0
(lb) - Max Horz B=317(LC 43)
Max Uplift All uplift 1001b or less atjoint(s) R, Y, Z, AA, AB, AC, AD, X, V except
U=-229(LC 6), T=-268(LC 7), S=-307(LC 6)
Max Grav All reactions 250 ib or less at joints) V except R=274(LC 25), B=318(LC 26),
Y=321 (LC 26), Z=325(LC 26), AA=323(LC 26), AB=327(LC 26), AC=308(LC 26),
AD=375(LC 26), X=334(LC 26), U=780(LC 25), T=872(LC 25), S=997(LC 25)
FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD B -C=-309179, C -D=-26010, D -E=-256/59
WEBS I -Y=-295/77, H -Z=-296/77, G -AA= -295176, F -AB= -299177, E -AC= -283/75, C -AD= -337186,
J -X=-299/76, M -U=-309/61, N -T=-290/57, O -S=-320/63
NOTES -
1) Wind: ASCE 7-10; Vul1=110mph (3 -second gust) Vasd=87mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category 11; Exp C; Fully Exp.; Ct= 1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs
non -concurrent with other live loads.
6) Provide adequate drainage to prevent water ponding.
7) All plates are 1.5x4 M720 unless otherwise indicated.
8) Gable requires continuous bottom chord bearing.
9) Gable studs spaced at 2-0-0 oc.
10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
11)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joints) R, Y, Z, AA, AS, AC,
AD, X, V except (jt -lb) U=229, T=268, S=307.
13) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSVTPI 1.
14) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
15) Graphical pudin representation does not depict the size or the orientation of the pudin along the top and/or bottom chord.
Continued on page 2
Job
ruse
I was I yp¢
Oty
yCopper
Creek loll blk 3 sky meadows
16-117653
J01A
Jaa-Closed Supported Gable
1
1
TC 0.13
Ven(LL)
0.00
A
n/r
120
Job Reference (optional)
111U. I PIU NUV 11 -1 aer
ID:eGufM8F01eHQ6wyuObfxBz4LyK-E9gtVaYD7kAPz5mR4a8XhDfBWuQRF44sb3ipkKyl qD
N M L K J I
Scale = 1:38.3
LOADING (pat)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)/dell
WEBS
L/d
PLATES GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.13
Ven(LL)
0.00
A
n/r
120
MT20 220/195
(Roof Snow=35.0)
Lumber DOL 1.15
BC 0.07
Vert(TL)
0.00
A
n/r
120
TCDL 7.0
Rep Stress Incr YES
WB 0.14
Horz(TL)
0.00
1
n/a
We
BCLL 0.0
Code IBC20121TP12007
(Matrix)
Weight: 741b FT=20%
BCDL 7.0
LUMBER -
TOP CHORD 2x4 OF 180OF 1.6E or 2x4 OF No.1&Btr
BOT CHORD 2x4 DF 1B00F 1.6E or 2x4 DF No.1&Btr
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
OTHERS 2x4 OF Stud/Std
REACTIONS. All bearings 12-0-0.
(lb) - Max Horz B=31 B(LC 8)
Max Uplift All uplift 100 Ib or less at joints) I, B, L. M, N, K, J
Max Grav All reactions 250 lb or less atjoint(s)1, B, L, M, N, K, J
FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
TOP CHORD B -C=-332/126, C -D=-269/108
BRACING -
TOP CHORD
Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS
1Row at midpt H-1
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
NOTES -
1) Wind: ASCE 7-10; Vult=110mph (3 -second gust) Vasd=87mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category II; Exp C; Fully Exp.; Ct=1
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 pat on overhangs
non -concurrent with other live loads.
5) All plates are 1.5x4 MT20 unless otherwise Indicated.
6) Gable requires continuous bottom chord bearing.
7) Gable studs spaced at 2-0-0 oc.
8) This truss has been designed for a 10.0 pal bottom chord live load nonconcurrent with any other live loads.
9)' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) I, B. L, M, N, K, J.
11) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
12) "Semi-rigid pitchbreaks with fixed heels" Member and fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job
NSe
russ I ype
ly
Ply
Capper Creak Ian blk 3 sky meallmas
16-117653
J01
Jack -Closed
3
1
Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD 2x4 OF 180OF 1.6E or 2x4 DF No.1&Bir
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 OF Stud/Std *Except*
WEBS
1 Row at midpt D -E
Job Reference (optional)
HMG (IDAHO FALLS), IDAHO FALLS, ID SU02 8.000 5 Jul 15 2016 MiTek Ind.st6a% Inc. Thu Nov 171517:16 2016 Pae 1
ID:eGufM8FOleHD6vvyuObtx8z4LyK-Inj75vWzb7vhjoc2y953boZkf4j?n4Ta7mDjfSyI qF
12-0-0
1-0-0 6-0-0 6-0-0
Scale = 1:38.3
LOADING (psf)
TCLL 35.0
(Roof Snow=35.0)
TCDL 7.0
BCLL 0.0
BCDL TO
SPACING- 2-0-0
Plate Grip DOL 1.15
Lumber DOL 1.15
Rep Stress Incr YES
Code IBC20121TPI2007
CSI.
TC 0.41
BC 0.20
WB 0.53
(Matrix)
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in (loc) I/deft Ud
-0.03 B -F >999 360
-0.06 B -F >999 240
0.01 E n/a We
0.03 B -F >999 240
PLATES GRIP
MT20 2201195
Weight 62 lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 OF 180OF 1.6E or 2x4 OF NoA&Bir
TOP CHORD
Sheathed or 6-0-0 oc purlins, except end verticals.
BOT CHORD 2x4 OF 180OF 1.6E or 2x4 DF No.1&Bir
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 OF Stud/Std *Except*
WEBS
1 Row at midpt D -E
W 1: 2x4 OF 180OF 1.6E or 2x4 OF No.1&Btr
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (Ib/size) E=568/Mechanical, 6=682/0-3-8 (min. 0-1-8)
Max Horz B=318(LC 8)
Max UpliftE=-219(LC 8), 6=50(LC 8)
FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (Ib) or lass except when shown.
TOP CHORD B -C=-729/0
BOT CHORD B -F=-195/499, E -F=-195/499
WEBS C -E=-595/233
NOTES -
1) Wind: ASCE 7-10; Vult=110mph (3 -second gust) Vasd=87mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category II; Exp C; Fully Exp.; Ct= 1
3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs
non -concurrent with other live loads.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5). This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ft
between the bottom chord and any other members.
6) Refer to girders) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B except Qt=lb) E=219.
8) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSUTPI 1.
9) "Semi-rigid pitchbreeks with fixed heels' Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job
mss
I ruse I ype
aty
ply
Copper Creek W2 blk 3 sky meadows
16-117653
H01
Roof Special Gltder
i
2
Job Reference Lori
BMC (IDAHO FALLS), IDAHO FALLS, ID 83982
Maas"" l 02ulb miteaircusNes,mC. Irnlrvovl/lb:l/:l/Lalli He 22
ID:eGufM8F01eHQ6vvyuObfx8z4LyK-ga9ktZWLgpng6elsORaq3al R1 hEi2XvQv8U97?yldgG
NOTES -
13) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
14) "Semi-rigid pitchbreaks with fixed heels" Member and fixity model was used in the analysis and design of this truss.
15) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
16) Use Simpson Strong -Tie LUS26 (4-10d Girder, 3-10d Truss, Single Ply Girder) or equivalent at 1-0-12 from the left and to connect truss(es) S03 (1 ply 2x4 DF) to front face of
bottom chord.
17) Use Simpson Strong -Tie LUS24 (4-10d Girder, 2-10d Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at 3-0-12 from the left end to 7-0-12 to connect
truss(es) S03 (1 ply 2x4 DF) to front face of bottom chord.
18) Use Simpson Strong -Tie HGUS28-2 (36-10d Girder, 12-10d Truss) or equivalent at 9-1-8 from the left end to connect truss(es) SO4 (2 ply 2x8 DF) to front face of bottom
chord.
19) Fill all nail holes where hanger is in contact with lumber.
LOAD CASE(5) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (pit)
Vert: A -E=-84, E -F=-84, F-1=-84, A -J=-14
Concentrated Loads (lb)
Vert: P= -5256(F) W= -636(F) X= -635(F) Y= -635(F) Z= -635(F)
o - _Truss
0-3-41 [13:0-4-0 ,0-3-01, IE:04-6
Irusks lype
y
y
Copper Creek 1012 blk 3 sky meadows
16-117653
Hot
Roof Special Girder
i
2
Job Reference (optional)
JMU 11UAN V ruLsl, xvA u rALLs, v u:wuz 8.000 s Jul 152016 M;Tek Industries, Inc. Thu Nov 1715:17:17 2016 Pae 1
ID:eGuftv78F01eH06vvyu0b7k8z4LyK-ga9ktZWLgpng6elsORaq3al R1 hEi2XvQv6U971yI�gG
LUS24 LUS24 LUS24 HGUS28-2
4-6-8 9-0-15 13-7-7 18-1-15 19-10-1 241-9 28-5-0 32-8-8
4-6-8 4-fi-8 4-6$ 4$$ 1 4$-8
Plate Offsets (X.Y)— fA:04-15
0-3-41 [13:0-4-0 ,0-3-01, IE:04-6
Edge? [P70-3-8,0-6-4]
TOP CHORD
T3: 2x4 DF Stud/Std
BOT CHORD 2x8 DF SS
BOT CHORD
WEBS 2x4 DF Stud/Std'Except*
WEBS
W1 1,W6,W3,W2,W1,W4:2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
Vde6
L/d
PLATES
GRIP
TCLL 35.0
(Roof Snow=35.0)
Plate Grp DOL 1.15
TO
0.91
Vert(LL)
-0.34
P
>999
360
MT20
220/195
TCDL 7.0
Lumber DOL 1.15
BC
0.78
Vert(TQ
-0.49
P
>796
240
MT20HS
165/146
BOLL 0.0
Rep Stress Incr NO
WB
0.94
Hoa(TL)
0.09
J
n/a
n/a
BCDL 7.0
Code IBC2012ITP12007
(Matrix)
Wind(LL)
0.14
P
>999
240
Weight:5171b
FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF N0.1&Btr *Except*
TOP CHORD
T3: 2x4 DF Stud/Std
BOT CHORD 2x8 DF SS
BOT CHORD
WEBS 2x4 DF Stud/Std'Except*
WEBS
W1 1,W6,W3,W2,W1,W4:2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
REACTIONS. (Ib/size) A=7641/05-8 (min. 0-4-8), J=3324/Mechanical
Max HorzA=199(LC 10)
Max Uplift&=-1477(LC 10), J=-591 (LC 11)
Max GravA=8476(LC 28), J=4242(LC 28)
Sheathed or 23-2 oc purlins, except end verticals, and 2-0-0 oc
pudins (5-1-8 max.): E -F.
Rigid ceiling directly applied or 10-0-0 oc bracing.
1 Row at midpt C -O
FORCES. (Ib) -Max. Comp./Max. Ten. -All fomes 250 (Ib) or less except when shown.
TOP CHORD A -R=-16456/2869, 8-R=-16355/2878, B -C=-14445/2609, C -S=-8924/1537, S -T=-8783/1543,
D -T=-8654/1552, D -E=-5747/989, E -F=-0659/835, F -G=-5360/919, G -U=-49171783,
H -U=-5059!769, H -V=-3777/578, I -V=4024/569, I -J=-4166/597
BOT CHORD A -W=-2725/14633, W -X=-2725/14633, Q -X=-2 72 5114 6 3 3, Q -Y=-2719/14590, Y -Z=-2719/14590,
P -Z=-2719/14590, O -P=-2403/12797, N -O=-1374/7856, M -N=-774/4961, L -M=-618/4398,
K -L=475/3489
WEBS B -Q=-170/1280, B -P=-1998/353, C -P=-1346/6617, C -O=-6897/1436, D -O=-1013/5073,
D -N=-5167/1072, E -N=-711/3617, E -M=-1630/359, F -M=363/1925, G -M=-290/919,
G -L= -1212/258,H -L=-226/1344, H -K= -2100/331,1-K=-54614040
NOTES -
1) 2 -ply truss to be connected togetherwith 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 -1 row at 0-4-0 oc.
Bottom chords connected as follows: 2x8 - 3 rows staggered at 0-2-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASES) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-10; Vu1t=110mph (3 -second gust) Vasd=87mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. 11; Exp C; enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
4) TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category 11; Exp C; Fully Exp.; Ct= 1
5) Unbalanced snow loads have been considered for this design.
6) Provide adequate drainage to prevent water ponding.
7) All plates are MT20 plates unless otherwise indicated.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 35-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
10) Refer to girder(s) for truss to truss connections.
11) Provide metal plate or equivalent at bearing(s) J to support reaction shown.
12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) except ()t=1b) A=1477
, J=591.
Continued on page 2
o
mse
mss ype
ly
y
Copper Creak lot2 blk 3 sky meadows
1641]853
G02
Raof Special
6
1
TOP CHORD Sheathed or 4-1-9 oc purlins, except end verticals.
BOT CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Blr
BOT CHORD Rigid ceiling directly applied or 9-3-11 oc bracing.
WEBS 2x4 OF 180OF 1.6E or 2x4 DF No.1&Btr *Except*
WEBS
1 Row at midpt D -H, E -H
Job Reference (optional)
BMC (IDAHO FALLS), IDAHO FALLS, ID 93402
D =1:44.4
LOADING (psf)
TCLL 35.0
(Roof Snow=35.0)
TCDL 7.0
BCUL
BCDL 7.0.
SPACING- 2-0-0
Plate Grip DOL 1.15
Lumber DOL 1.15
Rep Stress Incr YES
Code IBC2012rrP12007
CSI.
TO 0.83
BC 0.56
WB 0.26
(Matrix)
DEFL.
Vert( E)
Vert(TL)
HOrz(TL)
Wind(LL)
in (loc) I/deft Lld
-0.34 H-1 >879 360
-0.59 H -I >501 240
0.04 G n/a n/a
0.06 B -I >999 240
PLATES GRIP
MT20 220/195
Weight: 133 lb FT=20°/
LUMBER-
BRACING -
TOP CHORD 2x4 OF 180OF 1.6E or 2x4 DF N0.1&Blr
TOP CHORD Sheathed or 4-1-9 oc purlins, except end verticals.
BOT CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Blr
BOT CHORD Rigid ceiling directly applied or 9-3-11 oc bracing.
WEBS 2x4 OF 180OF 1.6E or 2x4 DF No.1&Btr *Except*
WEBS
1 Row at midpt D -H, E -H
W6: 2x4 DF Stud/Std
MiT ek recommends that Stabilizers and required cross bracing
gbe
installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (Ib/size) B=1343/0-5-8 (min. 0-1-8), G=1202/0-5-8 (min. 0-1-8)
Max HO2B=314(LC 10)
Max UpliftB=-232(LC 10), G=-217(LC 10)
FORCES. (lb) - Max. Comp./Max. Ten. -All fomes 250 (lb) or less except when shown.
TOP CHORD B -C=-2134/320, C -D=-1853/323, D -J=-789/139, EJ= -651/150, E -F=-764/170, F -G=-11761229
BOT CHORD B -I=-510/1794, 1-K=-33011195, K-L=.33D/1195, H -L=-330/1195
WEBS C -I=-4431210, D-1=-11 616 3 6, D -H=-881/307, F -H=-1661867
NOTES -
1) Wind: ASCE 7-10; Vult=110mph (3 -second gust) Vasd=87mph; TCDL=4.2psf, BCDL=4.2psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=35.0 psf (Flat roof snow); Category 11; Exp C; Fully Exp.; Ct=1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 18.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs
non -concurrent with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6)"This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tell by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.Opsf.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100Ib uplift at joint(s) except (jt=1b) B=232,
G=217.
8) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI7TPI 1.
9) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job
Truss
russ ype
ly
y
Copper Creak loft Ink 3 sky meadows
16-11 76 5 3
Gm
Roof Special
4
1
WEBS 2x4 DF Stud/Std "Except” WEBS
1 Row at midpt E -H
W6,W 1,W2: 2x4 DF 180OF 1.6E or 2x4 DF No. 1&Btr
MiTek recommends that Stabilizers and required crass bracing
be installed during truss erection, in accordance with Stabilizer
Job Reference (optional)
oma. gDAhw Fn Lof,mew,„iowvc a.uuu s Jul 1 b eulti Ml l en Inou9nes, Inc. nu Nov171517122616 Page
D:eGufMBF01eHQ6vvyuObfx8z4LyK-TdLrgrSCOH9Y7t9ucu_eMXJ bsgeCN KThlgmOSoyIDgL
12-8-0 19-0-0 25-0-0
1-3-7 8-0-0 6-0-0 64-0 i 6-0-0
M
es
3 = 1:44.4
LOADING (psf)
TCLL (Roof Snow=35.0)
TCDL 7,0
BCLL 0.0 '
BCLL 7.0
SPACING- 2-0-0 CSI.
Plate Grip DOL 1.15 TC 0.88
Lumber DOL 1.15 BC 0.35
Rep Stress Incr YES WB 0.69
Code IBC2012rrP12007 (Matrix)
DEFL. in
Vert(LL) -0.10
Vert(TL) -0.17
HOrzfTL) 0.03
Wind(LL) 0.05
floc) I/deft L/d
W >999 360
I -J >999 240
G n/a n/a
B -J >999 240
PLATES GRIP
MT20 220/195
Weight: 1431b FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 DF 180OF 1.6E or 2x4 DF No. 1&Blr TOP CHORD
Sheathed or 4-6-0 oc purlins, except end verticals.
BOT CHORD 2x4 DF 180OF 1.6E or 2x4 DF No. 1&Btr BOT CHORD
Rigid ceiling directly applied or 9-9-7 oc bracing.
WEBS 2x4 DF Stud/Std "Except” WEBS
1 Row at midpt E -H
W6,W 1,W2: 2x4 DF 180OF 1.6E or 2x4 DF No. 1&Btr
MiTek recommends that Stabilizers and required crass bracing
be installed during truss erection, in accordance with Stabilizer
Installation quids.
REACTIONS. (Ib/size) B=1208/0-5-8 (min. 0-1-8), H=1653/0-5-8 (min. 0-1-12), G=-314/Mechanical
Max HorzB=314(LC 10)
Max UpiiftB=-206(LC 10), H=-309(LC 10), G=-411(LC 3)
Max GravB=1208(LC 1), H=1653(LC 1), G=67(LC 10)
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD B -C=-1843/268, C -D=-1642/309, D -K=-8511192, E -K=-713!203, E -F=-83/282, F -G=-74/375
BOT CHORD B -J=463/1536, J -L=-275/937, L -M=-275/937, I -M=-275/937, I -N=-74/308, N -O=-74/308,
H -O=-74/308
WEBS C -J=448/210, D -J=-173/685, D -I=-817/309, E -I=-236/929, E -H=-11731278, F -H=-484/110
NOTES -
1) Wind: ASCE 7-10; Vult=110mph (3 -second gust) Vasd=87mph; TCDL=4.2psf,, BCDL=4.2psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category 11; Exp C; Fully Exp.; Ct= 1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 18.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs
non -concurrent with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrsnt with any other live loads.
6)' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.Opsf.
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joints) except at -1b) B=206,
H=309, G=411.
9) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSUfPI 1.
10) "Semi-rigid pitchbreaks with fixed heels' Member end fixity model was used In the analysis and design of this truss.
LOAD CASE(S) Standard
Job
mssruse
Type
CRY
y
Capper Creak loft blk 3 sky meadows
16-117653
E03
Hip
1
1
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
Job Reference (optional)
BMC (IDAHO FALLS), IDAHO FALLS, ID 63402
Scale =1:52.2
Plate Offsets (X Y)— fA,0-0-14
Edgel 13:0-3-0.0-3-41, [L:0-3-8
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
Edgel
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 OF No.t&Btr `Except*
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
B4: 2x4 DF Stud/Std
MiTek recommends that Stabilizers and required cross bracing
WEBS 2x4 DF Stud/Std *Except`
be installed during truss erection, in accordance with Stabilizer
W2,W6: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
I/deb
L/d
PLATES
GRIP
TCLL 35.0
Plate GOP DOL 1.15
TC 0.96
Vert(LL)
-0.51
M -N
>766
360
MT20
220/195
(Roof Snow=35.0)
Lumber DOL 1.15
BC 0.84
Vert(TL)
-0.90
M -N
>433
240
MT20HS
165/146
TCDL 7.0
Rep Stress Incr YES
WE 0.90
HDrz(TL)
0.65
1
n/a
n/a
BCLL 0.0
Code IBC2012/TPI2007
(Matrix)
Wind(LL)
0.26
M -N
>999
240
Weight: 1731b
FT=20%
BCDL 7.0
LUMBER-
BRACING -
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
TOP CHORD Sheathed, except end verticals.
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 OF No.t&Btr `Except*
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
B4: 2x4 DF Stud/Std
MiTek recommends that Stabilizers and required cross bracing
WEBS 2x4 DF Stud/Std *Except`
be installed during truss erection, in accordance with Stabilizer
W2,W6: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
Installation guide.
REACTIONS. (Ib/size) 1=1584/Mechanical, A=1584/0-5-8 (min. 0-1-10)
Max HorzA=214(LC 10)
Max Upliftl=-226(LC 11), A=-261(LC 10)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD A -B=-5340/1037, B -C=-4878/895, C -O=-3456/579, D -O=-3341/590, D -E=3388/673,
E -F=-0071/617, F -P=-3831/556, G -P=-3967/542, G -H=-1400/209, H -I=-1552/237
BOT CHORD A -N=-1108/4773, M -N=-842/4103, M -Q=-300/2262, Q -R=-300/2262, L -R=-30012262,
F -L=-682/201
WEBS B -N=-350/224, C -N=-71/504, C -M=-1055/352, D -M=-530/165, E -M=-426/2042, E -L=-370/2098,
G -L=-293/2332, G -J=-1926/280, H -J=-169/1414, J -L=-198/1656
NOTES -
1) Wind: ASCE 7-10; Vult=110mph (3 -second gust) Vasd=87mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed : Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=35.0 psf (Flat roof snow); Category 11; Exp C; Fully Exp.; Ct= 1
3) Unbalanced snow loads have been considered for this design.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6)"This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tell by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.Opsf.
7) Refer to girder(s) for truss to truss connections.
8) Bearing atjoint(s) A considers parallel to grain value using ANSIl 1 angle to grain formula. Building designer should verify capacity o
bearing surface.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=1b) 1=226,
A=261.
10) This truss is designed in accordance with the 2012 International Building Code section 2306.1. and referenced standard ANSIl 1.
11) "Semi-rigid pitchbreeks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
0Truss
SPACING- 2-0-0
mss ype
y
y
Capper Creek loll blk 3 sky meadows
ifi-11]653
E01
Roof Special
2
1
Vert(LL)
-0.48 T >812 360
MT20 220/195
TCDL 7.0
Lumber DOL 1.15
Job Refereecc (optional)
BMC (DAnv FALLS), DAHO FALLS, io a 000 s Jul 152016 MITek Indusines, Inc. Thu Nov 1715:1709 2016 Pal
ID:eGufM8F0leHQ6vvyu0bfx8z4LyK-32gjCgPJjMnzBPQJwmRxkuhAJS W bAwoF3$YkrTylogO
-1-3-7 41-6 8-2-12 12<2 16-5-8 18-0-121 0 23-6-13 28-1-11 32-8-8
1-3-] 41-6 4-164-14�-13 45-13 4-6-13
Scale = 1:54.4
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in floc) I/deo Uri
PLATES GRIP
TCLL 35.0
(Roof Snow=35.0)
Plate Grip DOL 1.15
TC 0.51
Vert(LL)
-0.48 T >812 360
MT20 220/195
TCDL 7.0
Lumber DOL 1.15
BC 0.73
Vert(TL)
-0.78 S -T >496 240
MT20HS 165/146
BCLL 0.0
Rep Stress Incr YES
WB 0.88
Horz(TL)
0.59 K We n/a
BCDL 7.0
Code IBC2012ITP12007
(Matrix)
Wind(LL)
0.24 T >999 240
Weight:2021b FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
TOP CHORD Sheathed or 2-6-12 oc purlins, except end verticals.
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr "Except"
BOT CHORD Rigid ceiling directly applied or 6-5-15 oc bracing.
134: 2x4 DF Stud/Std
JOINTS
1 Brace at A(s): O, P
WEBS 2x4 DF Stud/Std'Except*
MITek recommends that Stabilizers and required cross bracing
W7: 2x4 DF 1800F 1.6E or 2x4 DF NoA&Btr
be installed during truss erection, in accordance with Stabilizer
Installation guide,
REACTIONS. (Ib/size) K=1581/Mechanical, B=1720/05-8 (min.
0-1-12)
Max HorzB=233(LC 10)
Max UpliftK=-225(LC 11), B=-299(LC 10)
FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD B -C=-5148/992, C -D=-4963/945, D -E=-4440/822, E -V=-34371593, F -V=-3351/604,
F -G=-2684/498, G -H=-2549/463, H -W=3459/516,1 -W= -3547/501,1-J=-1472/220,
J -K=-15521240
BOT CHORD B -U=-1069/4561, T -U=-956/4463, S -T=-737/3840, RS= -46312951, P -R=-383/3103,
O -P=-383/3103
WEBS D -T=471/196, E -T=-106/505, E -S=$62/270, F -S=-274/1375, F -R=-1594/359, H -O=-61/708,
L -O= -197/1580,1-L=-1705/259, J -L=-171/1442, G -R=-370/1996, H -R=-1391/256,
1-0=-240/1881
NOTES -
1) Wind: ASCE 7-10; Vult=110mph (3 -second gust) Vasd=87mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cal. 11; Exp C; enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=35.0 psf (Flat roof snow); Category 11; Exp C; Fully Exp.; Ct= 1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 18.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs
non -concurrent with other live loads.
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.Opsf.
8) Refer to girder(s) for truss to truss connections.
9) Bearing atjoint(s) B considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of
bearing surface.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except (jt=1b) K=225,
B=299.
11) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
a
was
russ ype
ly
y
Capper Creek lot2 blk 3 sky meadm
16-117653
DO1
Roof Speclel
2
1
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
Job Reference (optional)
BMC (IDAHO FALLS), IDAHO FALLS, ID 03402
Scale = 1:56.1
8-2-12 16-5-6 22-7-13 2&10-1 33-2-0
8-2-12 8-2-72 6-2-5 fi-2-5 4-3-75
Plate Offsets (X Yl- (B'0
-D-14 Edg 1 !CO -3-0 0-3-41 tH
0-4-0 0-3-01 [J:0-6-0,0-7-8]
TOP CHORD Sheathed or 2-2-9 oc purlins.
T3: 2x6 DF 1800F 1.6E or 2x6 DF SS
BOT CHORD Rigid ceiling directly applied or 6-3-8 oc bracing.
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.i&Btr'Except*
MiTek recommends that Stabilizers and required cross bracing
B3,134: 2x10 OF SS
be installed during truss erection, in accordance with Stabilizer
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
I/deb
Lid
PLATES
GRIP
TCLL 35.0
Plate Grp DOL 1.15
TC 0.67
Vert(LL)
-0.57
L -M
-692
360
MT20
220/195
(Roof Snow=35.0)
Lumber DOL 1.15
BC 0.81
Vert(TL)
-0.99
L -M
>395
240
MT20HS
1651146
TCDL 7.0
Rep Stress lncr YES
WB 0.91
Horz(TL)
0.36
1
n/a
n/a
BCLL 0.0
Code IBC2012/TP12007
(Matrix)
Wind(LL)
0.28
L -M
>999
240
Weight: 2321b
FT=20%
BCDL 7.0
LUMBER-
BRACING -
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr'Except`
TOP CHORD Sheathed or 2-2-9 oc purlins.
T3: 2x6 DF 1800F 1.6E or 2x6 DF SS
BOT CHORD Rigid ceiling directly applied or 6-3-8 oc bracing.
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.i&Btr'Except*
MiTek recommends that Stabilizers and required cross bracing
B3,134: 2x10 OF SS
be installed during truss erection, in accordance with Stabilizer
WEBS 2x4 DF Stud/Std
Installation guide.
OTHERS 2x10 OF SS
LBR SCAB I -K 2x10 DF SS one side
REACTIONS. (Ib/size) B=1739/0-5-8 (min. 0-1-12), 1=1600/0-5-8 (min. 0-1-13)
Max Horz B=264(LC 10)
Max UpliftB=-293(LC 10), 1=-125(LC 10)
Max Gmv B=1739(LC 1), 1=1679(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD B -C=-5348/1025, C-13=4902/887, D -O=-3565/595, E-0=-3425/604, E -F=-3516/693,
F -G=-3966/594, G -P=4047/573, H -P=-4148/560
BOT CHORD B -M=-1125/4772, L -M=-879/4171, K -L=-342/2391, K -N=-340/2398, J -N=-34012398,
H -J=468/3606
WEBS C -M=-337/216, D -M=-54/468, D -L=-994/342, E -L=470/171, F -L=-435/1802, F -J=-252/2050,
G -J=-586/183
NOTES -
1) Attached 15-2-0 scab I to K, front faces) 200 DF SS with 2 row(s) of 10d (0.1131"x3") nails spaced 9" o.c.except : starting at 3-7-13 from
end at joint K, nail 2 row(s) at 7" o.c. for 2-0-0; starting at 9-10-1 from end at joint K, nail 2 row(s) at 3" c.c. for 2-0-0.
2) Wind: ASCE 7-10; Vult-11Omph (3 -second gust) Vasd=87mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
3) TCLL: ASCE 7-10; Pf=35.0 psf (Sat roof snow); Category Ii; Exp C; Fully Exp.; Ct= 1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 18.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs
non -concurrent with other live loads.
6) All plates are MT20 plates unless otherwise indicated.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) - This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9) Bearing at joint(s) B considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of
bearing surface.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift atjoint(s) except Qt=lb) B=293,
I=125.
11) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
Job
mss
I rusS I ype
Sheathed or 2-2-0 oc purlins, except end verticals, and 2-0-0 oc
Ply
Copper Creek lot2 blk 3 sky meadows
16417653
C81
Roof Special
2
1
2-0-0
CSI.
DEFL.
in
(loo)
Job Reference (optional)
BMC (IDAHO FALLS), IDAHO FALLS, ID 83402
Scale = 1:58.0
A
V
8-2-12 1 t6-5-8 1 26-2-1 33-2-0
8-2-12 8-2-12 9-8-9 6-11-15
Plate Offsets (X Y)— rB:0-0-14
Edge/ rC:0-3-0 0-3-41 [G:0-3-0,0-3-121
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr'Except• TOP CHORD
Sheathed or 2-2-0 oc purlins, except end verticals, and 2-0-0 oc
T3,T4: 2x6 OF 1BOOF 1.6E or 2x6 DF SS
purlins (3-5-5 max.): G -H.
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 OF No.i&Btr BOT CHORD
Rigid ceiling directly applied or 6-1-10 oc bracing.
WEBS 2x4 DF Stud/Std `Except`
MiTek recommends that Stabilizers and required cross bracing
LOADING (Psf)SPACING-
2-0-0
CSI.
DEFL.
in
(loo)
I/defi
Ud
PLATES
GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.84
Vert(LL)
-0.62
J -K
>635
360
MT20
220/195
(Roof Snow=35.0)
Lumber DOL 1.15
BC 0.80
Vert(TL)
-1.17
J -K
>338
240
MT20HS
165/146
TCDL 70)
BCU_ 0.0
Rep Stress Incr YES
WB 0.91
HOrz(TL)
0.40
1
n/a
n/a
MT18H
220/195
BCD_ 7.0
Code IBC2012/TP12007
(Matrix)
Wind(LL)
0.30
K -L
>999
240
Weight:1651b
FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr'Except• TOP CHORD
Sheathed or 2-2-0 oc purlins, except end verticals, and 2-0-0 oc
T3,T4: 2x6 OF 1BOOF 1.6E or 2x6 DF SS
purlins (3-5-5 max.): G -H.
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 OF No.i&Btr BOT CHORD
Rigid ceiling directly applied or 6-1-10 oc bracing.
WEBS 2x4 DF Stud/Std `Except`
MiTek recommends that Stabilizers and required cross bracing
W9,W2,W6: 2x4 OF 1800F 1.6E or 2x4 DF No.1&Btf
be installed during truss erection, in accordance with Stabilizer
Installation guide,
REACTIONS. (Ib/size) 1=1604/0-5-8 (min. 0-1-12),B=1743/0-5-8 (min. 0-1-12)
Max Holz B=296(LC 10)
Max Upliftl=-247(LC 11), B=-293(LC 10)
Max Gravl=1614(LC 18), B=1743(LC 1)
FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
TOP CHORD B -C=-5361/1053, C -D=-4916/918, D -M=-3541/614, E -M=-3425/626, E -F=-3458/706,
F -N=-5309/813, G -N=55431799, G -H=-5030/685, H-1=1553/264
BOT CHORD B -L=-1184/4783, K -L=-935/4166, J -K=-391/2348
WEBS C -L=-324/214, D -L=-60/476, D -K=-1045/347, E -K=-516/159, F -K=-440/2053, F -J=-520/3350,
G -J=-3181/570, H -J=-674/5003
NOTES -
1) Wind: ASCE 7-10; Vult=110mph (3 -second gust) Vasd=87mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. ll; Exp C; enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category It; Exp C; Fully Exp.; Ct= 1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs
non -concurrent with other live loads.
5) Provide adequate drainage to prevent water ponding.
6) All plates are MT20 plates unless otherwise indicated.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9) Bearing at joint(s) B considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of
bearing surface.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift at joint(s) except Qt=1b) 1=247,
B=293.
11) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
12) "Semi-rigid pitchbreaks with fixed heals" Member end fixity modal was used in the analysis and design of this truss.
13) Graphical pur in representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
o
Nas
mss ype
ly
y
Copper creeklol2blx3 sky moo, a
16-117653
1301
Roof Special
2
1
Sheathed or 2-2-8 oc purlins, except end verticals, and 2-0-0 oc
T3,T4: 2x6 DF 180OF 1.6E or 2x6 DF SS
purlins (4-5-2 max.): G -I.
BOT CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr
BOT CHORD Rigid ceiling directly applied or 6-0-8 oc bracing.
Job Reference (aptiona0
BMC(IDAHO FALLS). IDAHO FALLS, ID 63402 8.000SJUI152U1UMIlek IndUStneS,Inc. nu Nov1115:1C032016 Paggel
ID:eGufM8F01eH06vvyuObfx8z4LyK-EuJSxmLZ7 WOpOUzAaVKXUdS61153mCuM hw50d pylDgU
-1-3-7 5-5-13 10 -it -11 16-5-8 19-0-0 2&6-1 284-1 33-2-0
5-5-13 5-5-13 5-5-13 2-6-8 ~ 4-6-1 4-945 4-9-15
Scale =1:58.0
16-5-8
LOADING (psf) SPACING- 2-0-0
TCLL 35.0 Plate Gip DOL 1.15
(Roof Snow=35.0) Lumber DOL 1.15
TCDL 7.0 Rep Stress Incr YES
BCLL 0.0Code IBC201271`12007
BCDL 7.0
CSI.
TC 0.68
BC '0.60
WB 0.91
(Matrix)
DEFL.
Vert(CIL)
Vert(TL)
Horz(TL)
Wind(LL)
in (loc) I/deft Ltd
-0.51 L -M >778 360
-0.91 L -M >434 240
0.37 J me me
0.27 L -M >999 240
PLATES GRIP
MT20 220/195
MT20HS 165/146
Weight:170lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr *Except*
TOP CHORD
Sheathed or 2-2-8 oc purlins, except end verticals, and 2-0-0 oc
T3,T4: 2x6 DF 180OF 1.6E or 2x6 DF SS
purlins (4-5-2 max.): G -I.
BOT CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr
BOT CHORD Rigid ceiling directly applied or 6-0-8 oc bracing.
WEBS 2x4 DF Stud/Std
WEBS
1 Row at midpt H -J
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (Ib/size) J=160410-5-8 (min. 0-1-13), B=1743/0-5-8 (min. 0-1-12)
Max HorzB=324(LC 10)
Max UpliftJ=-256(LC 11), B=-287(LC 10)
Max GravJ=1720(LC 29), B=1743(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD B -C=-536511058, C -D=4920/922, D -N=-35341623, E -N=-3420/635, E -F=3472/719,
F -G=-39431611, G -O=-35001519, H-0=-3503/518, IJ= -290/56
BOT CHORD B -M=-1217/4787, L -M=-970/4161, K -L=414/2340, J -K=-354/2128
WEBS C -M=-324/214, D -M=-57/492, D -L=-1049/344, E -L=-538/168, F -L=475/2039, F -K=-301/2057,
G -K=-2310/389, H -K=-246/1622, H -J=-2502/432
NOTES -
1) Wind: ASCE 7-10; Vult=110mph (3 -second gust) Vasd=87mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS
(envelope) gable end zone; cantilever left and fight exposed ; Lumber DOL=1.33 plate gip DOL=1.33
2) TCLL: ASCE 7-10; Pf=35.0 psf (Bat roof snow); Category II; Exp C; Fully Exp.; Ct= 1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times fiat roof load of 35.0 psf on overhangs
non -concurrent with other live loads.
5) Provide adequate drainage to prevent water ponding.
6) All plates are MT20 plates unless otherwise indicated.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ft
between the bottom chord and any other members.
9) Bearing at joint(s) B considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of
bearing surface.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 10016 uplift at joint(s) except Gt=1b) J=256,
B=287.
11) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
12) "Semi-rigid pitchbreaks with fixed heels' Member end fixity model was used in the analysis and design of this truss.
13) Graphical puffin representation does not depict the size or the oientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
0
mss
rues ype
ly
y
Capper Greek laU blk 3 sky meadows
16-117553
A04
Common
5
1
DEFL.
in
(loc)
I/defl
Ud
PLATES GRIP
Job Reference (optional)
BMG pu nu rH w), iunnu
]-10-t2 15-9-8 239-8 31-9-8
]-10-12 7-10-12 8-0-0 8-0-0
31.7
Plate Offsets (X,Y)— tA:0-3-8,Edgel [E:0-0-0,0-0-41, [H:04.0,0-3-01
TOP CHORD
Sheathed or 2-2-0 cc purlins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 cc bracing.
WEBS
1 Row at midpt B-H, D -H
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
I/defl
Ud
PLATES GRIP
TCLL 35.0
(Roof Snow=35.0)
Plate Gdp DOL 1.15
TC 0.77
Vert(LL)
-0.15
A-1
>999
360
MT20 220/195
TCDL 7.0
Lumber DOL 1.15
BC 0.56
VerI TL)
428
E -G
>999
240
BCLL 0.0 `
Rep Stress Incr YES
WB 0.29
Horz(TL)
0.09
E
n/a
n/a
BCDL 7.0
Code IBC2012ITP12007
(Matrix)
Wind(LL)
0.11
A-1
>999
240
Weight:151lb FT=20%
LUMBER -
TOP CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr
BOT CHORD 2x4 DF 180OF 1.6E or 2x4 DF No. 1&Btr
WEBS 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr "Except`
W4,W5: 2x4 DF Stud/Std
WEDGE
Left: 2x4 DF Stud/Std
REACTIONS. (Ib/size) A=153710-5-8 (min. 0-1-10), E=1644/0-3-8 (min. 0-1-12)
Max Horz A=-267(LC 6)
Max Up1iRA=-228(LC 8), E=-261 (1-C 9)
BRACING -
TOP CHORD
Sheathed or 2-2-0 cc purlins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 cc bracing.
WEBS
1 Row at midpt B-H, D -H
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A -B=-2308/325, B -C=-1586/319, C -D=-1589/318, D -E=-2340/330
BOT CHORD A -J=-319/1848, 1.1=-319/1848, 1-K=-319/1845, H -K=-319/1845, H -L=-158/1792,
G -L=-158/1792, G -M=-157/1794, E.M=-157/1794
WEBS B-1=0/303, B -H=-834/311, C -H=-169/953, D -H=-879/317, D-G=D/300
NOTES -
1) Wind: ASCE 7-10; Vult=110mph (3 -second gust) Vasd=87mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. 11; Exp C; enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category 11; Exp C; Fully Exp.; Ct= 1
3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 pat on overhangs
non -concurrent with other live loads.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will ft
between the bottom chord and any other members, with BCDL = 7.Opsf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=1b) A=228,
E=261.
7) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/rP11.
8) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
0
Max
rues ype
ly
y
Capper Creak loF 1,111 slymealom
1fi-117653
AM
Common Struclurel Gable
1
1
16-0-0
20-0-0
WEDGE
24-0-0
be installed during truss erection, in accordance with Stabilizer
32-0-0
Job Reference (optional)
BMC (IDAHO FALLS), IDAHO FALLS, ID 03402 0.000sJultb2010MIlek Innuslnes,Inc. nu Nov111b:1bAtlz016 Paggel
ID:eGufM8F01eHQ6vvyuObfx8z4LyK.M73x5P124H WOxtfOLgGbKnHP7QBdgQOnm17CU2ylogY
1-04 8-0-0 16-0.0 240-0 32-0-0 3-0-0
10-0 8-0-0 8-0-0 6-0-0 8-0-0 11 -OAS
$1
3.8
LUMBER-
BRACING -
TOP CHORD 2x4 OF 180OF 1.6E or 2x4 DF No.1&Btr
TOP CHORD Sheathed or 4-3-4 oc purlins.
M
L AQ
K
J AR I
H
WEBS 1 Row at midpt C -N
BAA 1
16-0-0
20-0-0
WEDGE
24-0-0
be installed during truss erection, in accordance with Stabilizer
32-0-0
Installation guide.
8A-0
8-0-0
4-0-0
4-0-0
8), K=-268(LC B), H=-117(LC 9)
Max Grav All reactions 250 In or less atjoint(s) F, M, M, L, J, I except B=1223(LC 1), K=1564(LC 1), H=278(LC 1)
Plate Offsets(XY)- 1B:0-2-70-2-11
IF:0-2-70-2-11
LOADING (psf)
SPACING- 2-0-0CSI.
DEFL. in
(100)
I/defl
Ud
PLATES
GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.75
Verfl L) -0.12
B -O
>999
360
MT20
220/195
(Roof Snow=3
Lumber DOL 1.15
BC 0.45
Vert(TL) -0.23
B -O
>999
240
.
70
TCDL 70
Rep Stress Incr YES
WB 0.81
HOR(TL) 0.03
BCLL 0.0'
Code IBC2012ITP12007
(Matrix)
Wind(LL) 0.09
6-O
>999
240
Weight: 236 lb
FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 OF 180OF 1.6E or 2x4 DF No.1&Btr
TOP CHORD Sheathed or 4-3-4 oc purlins.
BOT CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing, Except:
WEBS 2x4 OF Stud/Std
10-0-0 oc bracing: B -0,N -O.
OTHERS 2x4 OF Stud/Std `Except*
WEBS 1 Row at midpt C -N
ST8: 2x4 DF 1800F 1.6E or 2x4 DF No.i&Btr
MiTek recommends that Stabilizers and required cross bracing
WEDGE
be installed during truss erection, in accordance with Stabilizer
Left: 2x4 DF Stud/Std, Right: 2x4 DF Stud/Std
Installation guide.
REACTIONS. All bearings 12-3-8 except at -length) B=0-3-8.
(lb)- Max Horz B=-272(LC 6)
Max Uplift All uplift 100 to or less at joint(s) F, L, I except B=-208(LC
8), K=-268(LC B), H=-117(LC 9)
Max Grav All reactions 250 In or less atjoint(s) F, M, M, L, J, I except B=1223(LC 1), K=1564(LC 1), H=278(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD B -C=-1801/238, C -D=-840/227, D -E=-839/226, E -F=-89/288
BOT CHORD B -AO= -252/1307, O -AO= -252/1307, O -AP= -252/1307, N -AP= -252/1307
WEBS E -N=-87/773, E -K=-15311283, C.N=-900/317, C-0=0/306
NOTES -
1) Wind: ASCE 7-10; Vult=110mph (3 -second gust) Vasd=87mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; enclosed; MWFRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category II; Exp C; Fully Exp.; Ct= 1
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs
non -concurrent with other live loads.
5) All plates are 1.5x4 MT20 unless otherwise indicated.
6) Gable studs spaced at 2-0-0 Do.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.Opsf.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) F, L, I except 6t=1b)
8=208, K=268, H=117.
10) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSI/TPI 1.
11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard
0
nlss
Nes ype
ly
y
Copper Creek to@blk 3 sky meado
16-117653
A02
Common
2
1
SPACING- 2-0-0
CSI.
Installation guide.
DEFL.
in
floc)
J h Referesnoe loptional)
o,e a, yu n�rnuol. �unnai rn,.w.w
Y
d
b3.6
[4
0
Plate Offsets (X,Y)— [A:0-0-0,0-0-47
(E:Edge 0-0-41 [H:04-0,0-3-0]
TOP CHORD
Sheathed or 2-2-0 oc purlins.
BOT CHORD
Rigid ceiling directly applied or 10.0-0 oc bracing.
WEBS
1 Row at midpt D -H, B-H
MiTek recommends that Stabilizers and required cross bracing
LOADTCLLL (Ps35.0
SPACING- 2-0-0
CSI.
Installation guide.
DEFL.
in
floc)
/deft
Vd
PLATES
GRIP
(Roof Snow=35.0)
Plate Grip DOL 1.15
TC
0.78
Vert(LL)
-0.17
A-1
>999
360
MT20
220/195
TCDL 7,0
Lumber DOL 1.15
BC
0.59
Vert(TL)
-0.31
A-1
>999
240
BCLL 0.0 `
Rep Stress Incr YES
WB
0.29
Horz(TL)
0.09
E
n/a
n/a
BCDL 7,0
Code IBC20121TPI2007
(Matrix)
Wind(LL)
0.11
A -I
>999
240
Weight: 1511b
FT=20%
LUMBER -
TOP CHORD 2x4 DF 1BOOF 1.6E or 2x4 DF No.1&Btr
BOT CHORD 2x4 OF 180OF 1.6E or 2x4 DF No.1&Bir
WEBS 20 DF 180OF 1.6E or 2x4 DF No.1&Btr `Except*
W3: 2x4 OF Stud/Std
REACTIONS. (Ib/size) A=1552/0-3-8 (min. 0-1-10),E=1669/0-3-8 (min. 0-1-12)
Max Horz A=-267(LC 4)
Max UpliftA=-232(LC 8), E=262(LC 9)
BRACING -
TOP CHORD
Sheathed or 2-2-0 oc purlins.
BOT CHORD
Rigid ceiling directly applied or 10.0-0 oc bracing.
WEBS
1 Row at midpt D -H, B-H
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
FORCES. (lb) -Max. Comp./Max. Ten. -All fomes 250 (lb) or less except when shown.
TOP CHORD A -B=-23731337, B -C=-1615/321, C -D=-16151322, D -E=-2365/333
BOT CHORD A -J=-33211916, 1.J=-332/1916, 1-K=-333/1912, H -K=-333/1912, H -L=-161/1812,
G -L=-161/1812, G -M=-160/1814, E.M=-160/1814
WEBS C -H=-171/974, D -H=-878/317, D -G=0/300, B -H=-8871321, B-1=01301
NOTES -
1) Wind: ASCE 7-10; Vult=110mph (3 -second gust) Vasd=87mph; TCDL=4.2psf; BCDL=4.2psf; h=25R; Cat. II; Exp C; enclosed; MW FRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category 11; Exp C; Fully Exp.; Ct= 1
3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs
non -concurrent with other live loads.
4) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads.
5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6.0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) except (jt=1b) A=232,
E=262.
7) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) A.
8) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSVTPI 1.
9) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
10) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n.
LOAD CASES) Standard
Job
ruse
Inuss ype
Cry
yCopper
Creak lal2 blk 3 sky meadows
16-117653
A01
Common
3
1
LOADING (psf)
SPACING- 2-0-0
Installation guide.
CSI.
DEFL.
in
Job Reference (optional)
BMC (IDAHO FALLS), IDAHO FALLS, ID 83402
e...,,.._ +.53.8
Plate Offsets (X Y)—
1B:0-0-0 0-0-01 1F:Edge 0-0-41 [1:0-4-0,03-01
TOP CHORD
Sheathed or 2-2-0 oc purlins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS
1 Row at midpt E-1, C-1
MiTek recommends that Stabilizers and required cross bracing
LOADING (psf)
SPACING- 2-0-0
Installation guide.
CSI.
DEFL.
in
(loc)
I/deb
L/d
PLATES
GRIP
TCLL 35.0
Plate Grip DOL 1.15
TC 0.77
Vert(LL)
-0.15
B -J
>999
360
MT20
220/195
(Roof Snow=35.0)
Lumber DOL 1.15
BC 0.54
Vert(TL)
-0.29
B -J
>999
240
TCDL 7.0
Rep Stress Incr YES
WB 0.29
Horz(TL)
0.09
F
n/a
n/a
BCLL 0.0
Code IBC2012/TPI2007
(Matrix)
Wind(LL)
0.10
B -J
>999
240
Weight: 152 lb
FT=20%
BCDL 7.0
LUMBER -
TOP CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr
BOT CHORD 2x4 DF 180OF 1.6E or 2x4 DF No.1 &Btr
WEBS 2x4 DF 180OF 1.6E or 2x4 DF No.1&Btr *Except'
W 3: 2x4 DF Stud/Std
REACTIONS. (Ib/size) B=1657/0-3-8 (min. 0-1-12),F=1657/0-3-8 (min. 0-1-12)
Max Horz B=-272(LC 6)
Max UpliftB=-262(LC 8), F=-262(LC 9)
BRACING -
TOP CHORD
Sheathed or 2-2-0 oc purlins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS
1 Row at midpt E-1, C-1
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
FORCES. (lb) - Max. Comp./Max. Ten. -All fomes 250 (lb) or less except when shown.
TOP CHORD B -C=-2361/332, C -D=-1611/320, D -E=-1611/320, E -F=2361/332
BOT CHORD B -K=328/1905, J -K=-328/1905, J -L=-328/1902, 1-L=-326/1902, 1-M=-160/1809,
H.M=-160/1809, H -N=-15911811, F -N=-159/1811
WEBS D -I=-169/970, E -I=-878/317, E -H=0/300, C -I=-878/316, C -J=0/300
NOTES -
1) Wind: ASCE 7-10; Vult=110mph (3 -second gust) Vasd=87mph; TCDL=4.2psf; BCDL=4.2psf; h=25f; Cat. II; Exp C; enclosed; MW FRS
(envelope) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL; ASCE 7-10; Pf=35.0 psf (flat roof snow); Category 11; Exp C; Fully Exp.; Ct= 1
3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf an overhangs
non -concurrent with other live loads.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5)' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.Opsf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt --1b) B=262,
F=262.
7) This truss is designed in accordance with the 2012 International Building Code section 2306.1 and referenced standard ANSVTPI 1.
8) "Semi-dgid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S) Standard