LOAD SHORT FORM - 17-00194 - 280 Baldwin - SFR
+ wrightsoft Load Short Form basement AH High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahco.com iLroject intormation For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 .h� 17-00►%Y Job: FS488 Date: 415117 By: Vince Byram HEATING EQUIPMENT Make Goodman Mfg. Design Information GOODMAN Htg Clg Infiltration Outside db (°F)• -6 89 Method Simplified Inside db (°F) 70 75 Construction quality Semi -tight Design TD (°F) 76 14 Fireplaces 0 Daily range - H Inside humidity (°/a) 50 50 Moisture difference (gr/Ib) 62 -31 HEATING EQUIPMENT Make Goodman Mfg. Trade GOODMAN Model GMSS960402BN AHRI ref 7365095 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 96.1 AFUE Goodman Mfg. 40000 Btuh 38000 Btuh 69 OF 600 cfm 0.079 cfm/Btuh 0.70 in H2O COOLING EQUIPMENT Make Goodman Mfg. Trade GOODMAN; JANITROL; AMANA DISTI... Cond GSX160181F Coil CAPT3131C4A AHRI ref 7365915 Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 12.5 EER, 15 SEER 11900 Btuh 5100 Btuh 17000 Btuh 567 cfm 0.394 cfm/Btuh 0.70 in H2O 1.00 Room17 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft') (Btuh) (Btuh) (cfm) (cfm) Room17 215 1571 382 123 150 Room15 631 3411 990 268 390 Room13 96 820 30 64 12 Room12 247 1832 37 144 15 basement AH d 1189 7634 1439 600 567 Other equip loads 0 0 Equip. @ 0.94 RSM 1352 Latent cooling 0 7/1 A1Q i 440A i IMOA I.IOCO i n i Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017 -Apr -05 08:13:24 wrj9NtSOft' Right -Suite® U niversal 201717.0.10 RSU20477 Paget ...wareWmtchnmAFS488 Ashland with basement.mp Calc =MJ8 House faces: N Building Analysis Job: FS4B8 wrightsoft 9 Y Date: 415117 AM By: Vince Byram High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highccuntryph@yahco.com Project Information For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Component Design Btuh %of load Walls Location: 13254 Indoor: Heating Cooling Idaho Falls, ID, US 17.3 Indoor temperature (°F) 70 75 Elevation: 4741 ft Ceilings Design TD (°F) 76 14 Latitude: 44°N 2.1 Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 61.5 -31.5 Dry bulb (°F) -6 89 Infiltration: 0 Dailyrange (°F) - 34 (H ) Method Simplified 0 Wetbulb(°F) - 60 Construction quality Semi -tight Adjustments Wind speed (mph) 15.0 7.5 Fireplaces 0 28112 100.0 Component Btuh/ft2 Btuh %of load Walls 4.9 13254 47.1 Glazing 24.3 4858 17.3 Doors 11.4 944 3.4 Ceilings 1.5 2459 8.7 Floors 2.1 1090 3.9 Infiltration 1.9 5508 19.6 Ducts 0 0 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 28112 100.0 Component Btuh/ft= Btuh %of load Walls 0.5 1273 17.5 Glazing 18.5 3687 50.8 Doors 2.8 230 3.2 Ceilings 0.8 1359 18.7 Floors 0.3 174 2.4 Infiltration 0.2 534 7.4 Ducts 0 0 Ventilation 0 0 Internal gains 0 0 Blower 0 0 Adjustments 0 Total 7257 100.0 Latent Cooling Load = 0 Btuh Overall U -value = 0.059 Btuh/ft;°F Data entries checked. .t WPt tl::sOfC 2017.Apn0508:13:24 }+ g Rig hl -Suite® U niversal 201717.0.10 RSU20477 Pagel t"'d ...ware\KadchnedFS4B8 Ashland with basement.rup Cale =MJ8 House faces: N ' wrightsoft° Building Analysis sis Job: FS468 Date: 415117 basement AH By: Vince Byram High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745.8056 Fax: 208-745.0817 Email: highwuntryphoyah°o.com Project Information For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Heating Component Design Btuh %of load Walls Location: 4227 Indoor: Heating Cooling Idaho Falls, ID, US 15.3 Indoor temperature (°F) 70 75 Elevation: 4741 ft Ceilings Design TD (°F) 76 14 Latitude: 44°N 1.5 Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 61.5 -31.5 Dry bulb (°F) -6 89 Infiltration: 0 Dailymnge (°F) - 34 ( H ) Method Simplified 0 Wetbulb(°F) - 60 Construction quality Semi -tight Adjustments Wind speed (mph) 15.0 7.5 Fireplaces 0 Heating Component BtuhhV Btuh %of load Walls 3.2 4227 55.4 Glazing 24.3 1167 15.3 Doors 0 0 0 Ceilings 1.5 152 2.0 Floors 1.5 1807 23.7 Infiltration 1.9 281 3.7 Ducts 0 0 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 7634 100.0 Component Btuh/ft2 Btuh % of load Walls 0.0 19 1.3 Glazing 27.3 1309 91.0 Doors 0 0 0 Ceilings 0.8 84 5.8 Floors 0 0 0 Infiltration 0.2 27 1.9 Ducts 0 0 Ventilation 0 0 Internal gains 0 0 Blower 0 0 Adjustments 0 Total 1439 100.0 Latent Cooling Load = 0 Btuh Overall U -Value = 0.035 Btuh/ft? °F WARNING: window to floor area ratio = 4.0% - less than 5%. wri Mt$oft2017-Apr-0508:13:24 Right -Suite® Unlvmsal 2017 17.0.10 RSU20477 Page 2 _...kKadchnedFS4B8 Ashland with basement.rup Calc =MJ8 House faces: N +I+ wrightsoft Component Constructions Dae: 4154B8 /17 basement AH By: Vince Syram High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208.745-8056 Fax: 208-745-0817 Email: highcountryph°Qyahoo.com Project• For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Construction descriptions Or Area U -value Insul R Htg HTM Loss CIg HTM Gain iF Bt 1'-'F ffl-'FBM Btuhit' Btuh BOW Bluh Walls 15B19-Owc-8: Bg wall, heavy dry or light damp soil, 2"x4" wood int frm, concrete wall, r-19 cav ins, 8" thk, 1/2" gypsum board int fnsh Partitions (none) Windows 61C: 61C: 6.67 I't head ht Doors (none) Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 cell ins, 1/2" gypsum board int fnsh Floors 21A -32c: Bg floor, heavy dry or light damp soil, 8' depth, carpet flr fnsh n 279 Design 19.0 3.28 916 Location: 6 Indoor: Heating Cooling Idaho Falls, ID, US 1153 Indoor temperature (°F) 70 75 Elevation: 4741 ft 19.0 Design TD (°F) 76 14 Latitude: 44°N W 335 Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 61.5 -31.5 Drybulb(°F) -6 89 Infiltration: 0.01 19 Dailyrange (°F) - 34 (H ) Method Simplified 778 Wetbulb(°F) - 60 Construction quality Semi -tight 0 Wind speed (mph) 15.0 7.5 Fireplaces 0 all 48 Construction descriptions Or Area U -value Insul R Htg HTM Loss CIg HTM Gain iF Bt 1'-'F ffl-'FBM Btuhit' Btuh BOW Bluh Walls 15B19-Owc-8: Bg wall, heavy dry or light damp soil, 2"x4" wood int frm, concrete wall, r-19 cav ins, 8" thk, 1/2" gypsum board int fnsh Partitions (none) Windows 61C: 61C: 6.67 I't head ht Doors (none) Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 cell ins, 1/2" gypsum board int fnsh Floors 21A -32c: Bg floor, heavy dry or light damp soil, 8' depth, carpet flr fnsh n 279 0.040 19.0 3.28 916 0.02 6 e 351 0.040 19.0 3.28 1153 0.02 7 s 351 0.040 19.0 3.11 1089 0.01 2 W 335 0.040 19.0 3.19 1069 0.01 4 all 1316 0.040 19.0 3.21 4227 0.01 19 s 32 0.320 0 24.3 778 18.9 604 w 16 0.320 0 24.3 389 34.4 551 all 48 0.320 0 24.3 1167 24.1 1155 100 0.020 50.0 1.52 152 0.84 84 1189 0.020 0 1.52 1807 0 0 201TApr-0508:13:25 Wrfghtsoft' Right -Suite® Universal 2017 M0.10 RSU20477 Paget AMN ...wareWartchner\FS4B8 Ashland with basement.rup Calc= MJ8 House faces: N Component Constructions Job: FS4B8 wrightsoft p Date: 415117 AM By: Vince Byram High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highwuntryph@yahoo.com For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Construction descriptions or Area 1.1 -value Insul R Htg HTM Loss Cig HTM Gain R Bluh4t'-°F ft'-°FHtun BtuhllF Btuh BtuhN stun Walls Firm wall, vnl ext, 3/8" wood shth, r-22 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud: Firm wall, vnl ext, 3/8" wood shth, r-22 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud Partitions (none) Windows 61 C: 61 C; 6.67 ft head ht Doors metal: Door, mil pur core type Ceilings 1613-50ad: Attic ceiling, asphalt shingles roof mat, r-50 cell ins, 1/2" gypsum board int fnsh Floors 19A-30bscp: Part floor, carpet fir fnsh, r-30 ins, firm flr, 12" thkns, 5/8" gypsum board int fnsh 21A -24c: Bg floor, heavy dry or light damp soil, 6' depth, carpet fir fnsh n 680 Design 22.0 4.94 3359 Location: 323 Indoor: Heating Cooling Idaho Falls, ID, US 3457 Indoor temperature (°F) 70 75 Elevation: 4741 ft 22.0 Design TD (°F) 76 14 Latitude: 44°N w 700 Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 61.5 -31.5 Dry bulb (°F) -6 89 Infiltration: 0.47 1273 Dailyrange (°F) - 34 (H ) Method Simplified 2140 Wetbulb(°F) - 60 Construction quality Semi -tight 0 Wind speed (mph) 15.0 7.5 Fireplaces 0 all 200 Construction descriptions or Area 1.1 -value Insul R Htg HTM Loss Cig HTM Gain R Bluh4t'-°F ft'-°FHtun BtuhllF Btuh BtuhN stun Walls Firm wall, vnl ext, 3/8" wood shth, r-22 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud: Firm wall, vnl ext, 3/8" wood shth, r-22 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud Partitions (none) Windows 61 C: 61 C; 6.67 ft head ht Doors metal: Door, mil pur core type Ceilings 1613-50ad: Attic ceiling, asphalt shingles roof mat, r-50 cell ins, 1/2" gypsum board int fnsh Floors 19A-30bscp: Part floor, carpet fir fnsh, r-30 ins, firm flr, 12" thkns, 5/8" gypsum board int fnsh 21A -24c: Bg floor, heavy dry or light damp soil, 6' depth, carpet fir fnsh n 680 0.065 22.0 4.94 3359 0.47 323 e 700 0.065 22.0 4.94 3457 0.47 332 IS 603 0.065 22.0 4.94 2981 0.47 286 w 700 0.065 22.0 4.94 3457 0.47 332 all 2683 0.065 22.0 4.94 13254 0.47 1273 n 88 0.320 0 24.3 2140 10.6 929 5 112 0.320 0 24.3 2718 18.9 2109 all 200 0.320 0 24.3 4858 15.2 3038 n 42 0.150 10.5 11.4 479 2.78 117 s 41 0.150 10.5 11.4 465 2.78 113 all 83 0.150 10.5 11.4 944 2.77 230 1618 0.020 50.0 1.52 2459 0.84 1359 435 0.034 30.0 2.17 944 0.40 174 77 0.025 0 1.90 145 0 0 2017 -Apr -05 08:13:25 Wrightsoft' Right-Suite9 uni,ersa1201717.0.10 RSU20477 Paget /iCiitl ...ware\Kanchner\F34B8 Ashland with basement.rup Calc = MJB House faces: N Project Summary Job: FS4B8 W rightsoft Date: 4/5/17 AH1 By: Vince eyram High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahco.com Proiect Information For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Notes: Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. W/'IQht$OiY' 2017 -Apr -0508:13:25 Right -Suite® Universal 2017 17.0.10 RSU20477 Page 1 ...ware\KartchneAFS4B8 Ashland with basemenhrup Calc =M.18 House faces: N Design Information Weather: Idaho Falls, ID, US Winter Design Conditions Summer Design Conditions Outside db -6 'F Outside db 89 OF Inside db 70 'F Inside db 75 OF Design TD 76 'F Design TO 14 OF Daily range H Relative humidity 50 % Moisture difference -31 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 28112 Btuh Structure 7257 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 28112 Btuh Use manufacturer's data n Rate/swing multiplier 0.94 Infiltration Equipment sensible load 6822 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi -tight Fireplaces 0 Structure -742 Btuh Ducts 0 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft') 2760 2760 Equipment latent load 0 Btuh Volume (fta) 24839 24839 Air changes/hour 0.19 0.10 Equipment total load 6822 Btuh Equiv. AVF (cfm) 78 41 Req. total capacity at 0.70 SHR 0.8 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg. Make Goodman Mfg. Trade GOODMAN Trade GOODMAN; JANITROL; AMANA DISTI... Model GMSS960603BN Cond GSX160181F AHRI ref 7365096 Coil CAPT3131N4A AHRI ref 7365915 Efficiency 96.1 AFUE Efficiency 12.5 EER, 15 SEER Heating input 60000 Btuh Sensible cooling 11900 Btuh Heating output 58000 Btuh Latent cooling 5100 Btuh Temperature rise 70 OF Total cooling 17000 Btuh Actual air flow 900 cfm Actual air flow 567 cfm Air flow factor 0.032 cfm/Btuh Air flow factor 0.078 cfm/Btuh Static pressure 0.70 in H2O Static pressure 0.70 in H2O Space thermostat Load sensible heat ratio 1.00 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. W/'IQht$OiY' 2017 -Apr -0508:13:25 Right -Suite® Universal 2017 17.0.10 RSU20477 Page 1 ...ware\KartchneAFS4B8 Ashland with basemenhrup Calc =M.18 House faces: N -�- Project Summary Job: FS4B6 wrightsofts Date: 415117 basement AH By: Vince Byram High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highwuntryph@yahw.com For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Notes: Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. TF Wrightilli Right -Subs® Universal 2017 17.0.10 RSU20477 2017-Apr-05 0 Peet ...ware\KatichneAF84B8 Ashland with basemenlmp Calc =MJB House faces: N 9 Weather: Idaho Falls, ID, US Winter Design Conditions Summer Design Conditions Outside db -6 of Outside db 89 °F Inside db 70 of Inside db 75 °F Design TD 76 of Design TD 14 °F Daily range H Relative humidity 50 % Moisture difference -31 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 7634 Btuh Structure 1439 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 7634 Btuh Use manufacturer's data n Rate/swing multiplier 0.94 Infiltration Equipment sensible load 1352 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi -tight Fireplaces 0 Structure -38 Btuh Ducts 0 Btuh Heatin Cooling Central vent 0 cfm Ent 0 Btuh Area (ft') 1189 1189 Equipment la load 0 Btuh Volume (ft') 1189 1189 Air changes/hour 0.20 0.11 Equipment total load 1352 Btuh Equiv. AVF (cfm) 4 2 Req. total capacity at 0.70 SHR 0.2 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg. Make Goodman Mfg. Trade GOODMAN Trade GOODMAN; JANITROL; AMANA DIST[... Model GMSS960402BN Cond GSX160181F AHRI ref 7365095 Coil CAPT3131C4A AHRI ref 7365915 Efficiency 96.1 AFUE Efficiency 12.5 EER, 15 SEER Heating Input 40000 Btuh Sensible cooling 11900 Btuh Heating output 38000 Btuh Latent cooling 5100 Btuh Temperature rise 69 °F Total cooling 17000 Btuh Actual air flow 600 cfm Actual air flow 567 cfm Air flow factor 0.079 cfm/Btuh Air flow factor 0.394 cfm/Btuh Static pressure 0.70 in H2O Static pressure 0.70 in H2O Space thermostat Load sensible heat ratio 1.00 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. TF Wrightilli Right -Subs® Universal 2017 17.0.10 RSU20477 2017-Apr-05 0 Peet ...ware\KatichneAF84B8 Ashland with basemenlmp Calc =MJB House faces: N 9 µ AED Assessment Job: FS488 wrightso1 {�' Date: 4/5117 AM By: Vince Byram High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com Project Information For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Conditions Location: Indoor: Heating Cooling Idaho Falls, ID, US Indoor temperature (°F) 70 75 Elevation: 4741 ft Design TD (°F) 76 14 Latitude: 44°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 61.5 -31.5 Dry bulb (T) -6 89 Infiltration: Dailyrange (°F) - 34 ( H ) Wetbulb(°F) - 60 Wind speed (mph) 15.0 7.5 Test for Adequate Exposure Diversity w,.ao-ai I wy � mars i .eo i mei Maximum hourly glazing load exceeds average by 45.4%. Zone does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 649 Btuh (PFG - 1.3'AFG) 2017 -Apr -0508:13:25 C wrightsoft' Rig H-suiteeUniversal201717.0.10RSU20477 Pagel AM,..wareWarohneMS4B8 Ashland with basement.mp Calc =MJ8 House faces: N +- wrightsoft' AED Assessment basement AH High Country Heating P.O. Bax 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com For: Location: Idaho Falls, ID, US Elevation: 4741 ft Latitude: 44°N Outdoor: Drybulb (°F) Dailyrange (°F) Wet bulb (°F) Wind speed (mph) Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Heating Cooling -6 89 - 34 (H ) - 60 15.0 7.5 off F -TUM T MO E t;mmru=- Job: FS489 Date: 4/5/17 By: Vince Byram Indoor: Heating Indoor temperature (°F) 70 Design TD (°F) 76 Relative humidity (%) 50 Moisture difference (gr/Ib) 61.5 Infiltration: ao AE) I Ill Maximum hourly glazing load exceeds average by 41.4%. Zone does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 154 Btuh (PFG - 1.3'AFG) Cooling 75 14 50 -31.5 2017 -Apr -05 08:13:25 wrightssoft' Right -shit. Universal 2017 17.0,10 Rsu20477 Paget B& ...w.re\Kadchner\FS4B8 Ashland with basement.mp Calc= MJ8 House faces: N wrightsoft• Right -M) Worksheet Job: FS4BB AHI Date: 4/5/17 High Country Heating By: Vince Byram P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745.0817 Email: highcountryph@yahoo.com 1 Room name AM (Rest of House Air) 2 Exposed wall 329.5 It 329.5 It 3 Room height 9.0 8 d 9.0 8 p 4 Room dimensions 5 Room area 2759.9 fP 2759.9 fP Ty Construction U -value I Or I HTM I Area (ft-) Load Area (f P) Load number (Bt uh/f 1'-°F (Btuhlf l') or perimeter (8) (Bluh) or perimeter (it) I (Btuh) Heal Cool Gross NIP/S Heat Cool Gross NIP/S Heat Coal B W 15B19 -B 0.069 n 0.00 0.00 0 0 0 0 0 0 0 1-� 0 wa F. wall, vnl ext, 3 0.065 n 4.94 0.47 810 680 3359 323 810 680 3359 323 61C1C 0.320 n 24.32 10.56 88 0 2140 929 88 0 2140 929 metal 0.150 11.40 2.78 42 42 479 117 42 42 479 177 17 W wo- 75819-08 0.069 a a 0.00 0.00 0 0 0 0 0 0 0 0 W Fria wall, vnl ext. 3 0.065 a 4.94 0.47 700 700 3457 332 700 700 3457 332 W 15879-0WOS 0.069 s 0.00 0.00 0 0 0 0 0 0 0 0 �G 61C 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 Fnn wall, vat ext, 3 0.065 s 4.94 0.47 756 603 2981 286 756 603 2981 286 61C 0.320 a 24.32 18.88 112 0 2718 2109 112 0 2718 2109 metal 0.150 s 11.40 2.78 41 41 465 113 41 41 465 113 W 15819-Owo-8 0.069 w 0.00 0.00 0 0 0 0 0 0 0 0 �G 61C 0.320 w 0.00 0.00 0 0 0 0 0 0 0 0 W Finn wall, vat em, 3 0.065 w 4.94 0.47 700 700 3457 332 700 700 3457 332 C 16B-50ad 0.020 1.52 0.84 1618 1618 2459 1359 1618 1618 2459 1359 F 19A-30bsco 0.034 2.17 0.40 435 435 944 174 435 435 944 174 F 21A -24c 0.025 - 1.90 0.00 77 77 145 0 77 77 145 0 F 21A -32c 0.020 - 0.00 0.00 0 0 0 0 0 0 0 0 61 c) AED excursion 649 3095 Envelope loss/gain 1 226041 67231 1 22604 9169 12 a) Infiltration 5508 534 5508 534 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) i 28112 7257 28112 9703 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 28112 7257 28112 9703 15 Duct loads 0% 0% 0 0 0% 0% 0 0 load I 289001 75871 289001 97581 Alrrequlreroomd(cfm) I �J� Calculations aooroyed by ACCA to meet all requirements of Manual J 8th Ed. -TPr- WrightlolF!' 2017 -Apr -0508:13:25 Right-basemt U.rup ale= 1017 Hou0. 10 R faces: 7 Pagel ...ware\KartchneAFS4B8 Ashland with basement.mp Calc=MJB House faces: N wrightsoft- Right -J® Worksheet Job: FS4B8 basement AH Date: 415117 High Country Heating By: Vince Byram P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.com 1 Room name basement AH Room17 2 Exposed wall 151.5 it 29.5 6 3 Room height 9.0 ft d 9.0 ft heat/cool 4 Room dimensions 16.5 x 13.0 ft 5 Room area 1188.5 R' 214.5 ft' Ty ConstructionU-value U -value Or HTM Area (ft') Load I Area (ft') I Load I number ( (Btuh/fl') or perimeter (8) (Stub ) or perimeter (9) (Blah) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heal Cool 6 W 1SB19-Owc-8 0.069 n 3.28 0.02 279 279 916 6 0 0 0 0 F. wall, W ext, 3 0.065 n 0.00 0.00 0 0 0 0 0 0 0 0 61C 0.320 n 0.00 0.00 0 0 0 0 0 0 0 0 metal 0.150 n 0.00 0.00 0 0 0 0 0 0 0 0 11 W 15819-0wo8 0.069 a 3.28 0.02 351 351 1153 7 117 117 384 2 W F. wall, vnl eat. 3 0.065 a 0.00 0.00 0 0 0 0 0 0 0 0 15819-OWC-8 0.069 a 3.11 0.01 383 351 1089 2 149 133 404 0 81C 0.320 a 24.32 18.88 32 0 778 604 16 0 389 302 Fm wall, vni ext, 3 0.065 s 0.00 0.00 0 0 0 0 0 0 0 0 61C 0.320 s 0.00 0.00 0 0 0 0 0 0 0 0 metal 0.150 s 0.00 0.00 0 0 0 0 0 0 0 0 W 15819-Owc.8 0.069 w 3.19 0.01 351 335 1069 4 0 0 0 0 I -G 61C 0.320 w 24.32 34.42 16 0 389 551 0 0 0 0 W Frm wall, vnl ext, 3 0.065 w 0.00 0.00 0 0 0 0 0 0 0 0 C 168-50ad 0.020 - 1.52 0.84 100 100 152 84 8 8 13 7 F 19A-30bsco 0.034 - 0.00 0.00 0 0 0 0 0 0 0 0 F 21A -24c 0.025 - 0.00 0.00 0 0 0 0 0 0 0 0 F 21A -32c 0.020 1.52 0.00 1189 1189 1807 0 215 215 326 0 61 c)AED excursion i1641 1 i65 Envelope losslgain 7353 1411 1516 376 12 a) Infiltration 281 27 55 5 b) Roomventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 7634 1439 1571 382 Less external load 0 01 0 0 Less transfer 0 01 0 0 Redistribution 0 0 0 0 14 Subtotal 7634 1439 1571 382 15 Duct loads 0% 0% 0 0 -0% 0% 0 0 TI room load182 7634 143 1571 Air18equired (c m) I I 6001 5671 I I 1231 1501 Calculations aooroved by ACCA to meet all reauirements of Manual J 8th Ed - A+WrightsOff' 2017 -Apr -0508:13:25 Right -Sus e®Universal e = N 17.0.10 Rfaces: 7 Page 2 ...ware\Kanchner\F54B8 Ashland with hasemenLmp Calc=MJB House faces: N wrightsoft• Right -A) Worksheet Job: FS4138 basement AH Date: 4/5117 High Country Heating By: Vince Byram P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-7454817 Email: highcountryph@yahoc.com 1 Room name Room 15 Rcoml3 2 Exposed wall 57.0 fl 20.0 fl 3 Room height 9.0 It heat/cool 9.0 It heat/cool 4 Room dimensions 1.0 x 631.0 ft 12.0 x 8.0 It 5 Room area 631.0 ft' 96.0 ft' Ty Construction U -value Or HTM Area (ft2) Load I Area (ft') Load number (Btuh/fP-°F I (Btuh/f P) or perimeter (0) tI3 h) I or perimeter (8) I (Btuh) Heat Cool Gross I NIP/S j Heat Cool Gross NIPS Heat Cool 6 W 15619-0wFe 0.069 n 3.28 0.02 0 0 0 0 108 108 355 2 Fm wall, vnl ext, 3 0.065 n 0.00 0.00 0 0 0 0 0 0 0 0 61C 0.320 n 0.00 0.00 0 0 0 0 0 0 0 0 metal 0.150 a 0.00 0.00 0 0 0 0 0 0 0 0 11 W 151319owF8 0.069 a 3.28 0.02 45 45 148 1 72 72 237 1 W Fm wall, vat ext. 3 0.065 a 0.00 0.00 0 0 0 0 0 0 0 0 VII 151319-owcB 0.069 s 3.11 0.01 234 218 685 2 0 0 0 0 -G 61C 0.320 s 24.32 18.88 16 0 389 302 0 0 0 0 Fan wall, vat ext, 3 0.065 5 0.00 0.00 0 0 0 0 0 0 0 0 61C 0.320 a 0.00 0.00 0 0 0 0 0 0 0 0 metal 0.150 s 0.00 0.00 0 0 0 0 0 0 0 0 t 151319-owo-8 0.069 w 3.19 0.01 234 218 685 2 0 0 0 0 -G MC 0.320 w 24.32 34.42 16 0 389 551 0 0 0 0 W Fnn wall, vnl and, 3 0.065 w 0.00 0.00 0 0 0 0 0 0 0 0 C 16B-50ad 0.020 1.52 0.84 33 33 51 28 30 30 46 25 F 19A-30bscp 0.034 0.00 0.00 0 0 0 0 0 0 0 0 F 21A -24c 0.025 - 0.00 0.00 0 0 0 0 0 0 0 0 F 21A -32c 0.020 - 1.52 0.00 631 631 959 0 96 96 146 0 61 c) AED excursion 95 -3 Envelope loss/gain 3305 980 783 26 12 a) Infiltration 106 10 37 4 b) Room ventilation 0 0 p 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 3411 990 820 30 Less external load 1 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3411 990 820 30 15 Duct loads -0% 0% 0 0 -0% 0%load 0 0 31 88Toegule rd I I 1 I 48' 1 121 Calculations approved by ACCA to meet all repuirements of Manual J 8th Ed ...Wrl ht■Of' Rig ht- e®U sal 17. 0.10R 7 2017-Apr-0508:13:25�A wareKatichnetlFS4B8 Ashland wih basemenL.rup Cale=MJB House faces: N Page 3 wrightsof - Right-& Worksheet Job: FS4B8 basement AH Date: 4/5117 High Country Heating By: Vince Byram P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208.745-0817 Email: highcountryphQyahoo.com 1 Room name Rooml2 2 Exposed wall 45.0 8 3 Room height 9.0 It heat/cool 4 Room dimensions 19.0 x 13.0 fl 5 Room area 247.0 fi' T TY Construction U -value Or HTM I Area fP I Load I Area Load number (Bl uh/ft"F (Bluh/f t°) or perimeter (0) (Btuh) or perimeter Heat Cool Grass N/P/S Heat Cool Gross N/P/S Heal Cool 6 W 15819-Owo-8 0.069 n 3.28 0.02 171 171 562 3 F. wall, vnl ext, 3 0.065 n 0.00 0.00 0 0 0 0 61C 0.320 n 0.00 0.00 0 0 0 0 metal 0.150 n 0.00 0.00 0 0 0 0 11 W 15819-owc8 0.069 a 3.28 0.02 117 117 384 2 W Fan wall, vat ext. 3 0.065 a 0.00 0.00 0 0 0 0 15879-0wo-8 0.069 s 3.11 0.01 0 0 0 0 (1C 0.320 s 24.32 18.88 0 0 0 0 Fm wall, vat ext, 3 0.065 5 0.00 0.00 0 0 0 0 61C 0.320 s 0.00 0.00 0 0 0 0 metal 0.150 s 0.00 0.00 0 0 0 0 Vy 15BlMv>8 0.069 w 3.19 0.01 117 117 384 2 L --G 61C 0.320 w 24.32 34.42 0 0 0 0 W Fm wall, vnl ext. 3 0.065 w 0.00 0.00 0 0 0 0 C 188-50ad 0.020 - 1.52 0.84 28 28 43 24 F 19A-30bsw 0.034 0.00 0.00 0 0 0 0 F 21A -24c 0.025 0.00 0.00 0 0 0 0 F 21A -32c 0.020 - 1.52 0.00 247 247 375 0 61 c) AED 31 1 Envelope loss/gain 1749 29 12 a) Infiltration 84 8 b) Roomvenlilalion 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13) 1832 37 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 1832 37 15 Duct loads -0% 0% 0 0 Total room load 1832 37 Air required (cfm) 144 15 J. Calculations aooroved by ACCA to meet all reauirements of Manual J 8th Ed. gam, "*� wriQhtaoft' 2017 -Apr -0508:13:25 ACGA d with base®Universal rpe = M 17.0.10 Rfaces: 7 Page 4 ...ware\KadchneAFS4B8 Ashland with basement.mp Calc= MJ8 House faces: N 2nd Story Job #: FS4138 Performed by Vince Byram for: Cody Puzey 3758 Vellowslones Hwy Idaho Falls, Id 83401 Phone: 208-529-2116 High Country Heating P.O. Box 627 Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 highwuntryph@yahoo.com Scale: 1 : 78 Page 1 Right -Suite® Universal 2017 17.0.10 RSU20477 2017 -Apr -05 08:13:55 ...FS4B8 Ashland with basemenl.rup Main Floor Job #: FS4B8 Performed by Vince Byram for: Cody Puzey 3758 Vellowstones Hwy Idaho Falls, Id 83401 Phone: 208-529-2116 High Country Heating P.O. Box 627 Rigby, Id 83442 Phone: 208-745-8056 Fax 208-745-0817 highcountryph@yahoo.com Scale: 1 : 78 Page 2 Right -Suite® Universal 2017 17.0.10 RSU20477 2017 -Apr -05 08:13:55 ...FS4B8 Ashland with basement.rup basement Job #: FS4B8 Performed by Vince Byram for: Cody Puzey 3758 Yellowstones Hwy Idaho Falls, Id 83401 Phone: 208-529-2116 High Country Heating P.O. Box 627 Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 highcountryph@yahoo.com 30 cfm Scale: 1 :78 Page 3 Rig ht -Suite® Universal 2017 17.0.10 RSU20477 2017 -Apr -05 08:13:55 ...FS4B8 Ashland with basement.rup +I+ wrightsoft Duct System Summary AM High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highwuntrypha@yahoo.com Project Information For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Job: Fs4B8 Date: 415/17 By: Vince Byram Supply Branch Detail Table Name Heating Cooling External static pressure 0.70 in H2O 0.70 in H2O Pressure losses 0.30 in H2O 0.30 in H2O Available static pressure 0.40 in H2O 0.40 in H2O Supply / return available pressure 0.218 / 0.182 in H2O 0.218 / 0.182 in H2O Lowest friction rate 0.078 in/100ft 0.078 in/100ft Actual air flow 900 cfm 567 cfm Total effective length (TEL) Rooms -A 513 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Rooms h 472 53 37 0 0 0x0 ShMt 0 0 Peak AVF Rooms -A h 1671 53 37 0.082 6.0 0x0 ShMt 34.3 230.0 st4 Rooml-B h 1671 53 37 0.124 6.0 0x0 ShMt 15.8 160.0 st3 Rooml-C h 1671 53 37 0.091 6.0 Ox 0 ShMt 40.3 200.0 st4 Rooml-D h 1671 53 37 0.122 6.0 0x0 ShMt 3.3 175.0 st4 Rooms -E h 1671 53 37 0.085 6.0 0x0 ShMt 45.8 210.0 st4 Rooml-F h 1671 53 37 0.078 6.0 0x0 ShMt 34.3 245.0 st4 Room10 h 2131 68 50 0.115 6.0 0x0 ShMt 30.3 160.0 st4 Room11 h 3432 110 66 0.083 7.0 0x0 ShMt 42.8 220.0 st4 Room2-A h 367 12 3 0.088 6.0 0X0 ShMt 8.8 240.0 st4 Room4 c 1747 102 136 0.082 7.0 0x0 ShMt 30.8 235.0 st4 Rooms c 874 35 68 0.086 6.0 0x0 ShMt 14.3 240.0 st4 Rooms c 1396 80 109 0.098 7.0 0x0 ShMt 17.8 205.0 st3 Room7 h 579 19 9 0.099 6.0 0x0 ShMt 5.3 215.0 st3 Room8 h 527 17 8 0.129 6.0 0X0 ShMt 9.3 160.0 st3 Rooms h 2598 83 51 0.098 6.0 0X0 ShMt 27.3 195.0 st3 Supply Trunk Detail Table 2077 -Apr -0508:13:25 wrightsoft Right -Suite® Universal 2017 17.0.10 RSU20477 Pagel ...ware\Karlchne6FS4B6 Ashland with basement.rup Calc =MJ8 House faces: N Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 Peak AVF 252 213 0.098 378 8.3 8 x 12 ShtMetl st4 Peak AVF 595 508 0.078 669 11.9 8 x 16 ShtMetl 2077 -Apr -0508:13:25 wrightsoft Right -Suite® Universal 2017 17.0.10 RSU20477 Pagel ...ware\Karlchne6FS4B6 Ashland with basement.rup Calc =MJ8 House faces: N Return Branch Detail Table Name Grille Htg clg TEL Design Veloc Diam H x W Stud/Joist Duct Peak AVF Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Mall Trunk rb15 0x0 107 74 134.8 0.135 545 6.0 Ox 0 ShMt rt4 rb18 0x0 247 271 152.3 0.120 613 9.0 Ox 0 ShMt rt4 rb19 0x0 267 226 182.8 0.100 603 9.0 Ox 0 ShMt rb16 0x0 160 111 233.3 0.078 460 8.0 Ox 0 ShMt rt4 rb17 0x0 119 76 84.8 0.215 605 6.0 Ox 0 ShMt rt4 Name Trunk Type Htg (cfm) clg (cfm) Design FR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk rt4 Peak AVF 633 531 0.078 570 12.2 8 x 20 ShtMetl 2017 -Apr -0508:13:25 wrlghtsoft' Right -Suite® Universal 2017 17.0.10 RSU20477 Paget ...Ware\Kartchner\FS4B8 Ashland with basement.wis Cale =Wit House faces: N + wrightsoft Duct System Summary basement AH High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryph@yahoo.wm Project Information For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Job: FS4B8 Date: 415117 By: Vince Byram Supply Branch Detail Table Name Heating Cooling External static pressure 0.70 in H2O 0.70 in H2O Pressure losses 0.30 in H2O 0.30 in H2O Available static pressure 0.40 in H2O 0.40 in H2O Supply / return available pressure 0.232 / 0.168 in H2O 0.232 / 0.168 in H2O Lowest friction rate 0.105 in/100ft 0.105 in/100ft Actual air flow 600 cfm 567 cfm Total effective length (TEL) Room12-A 380 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Clam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Room12 h 916 72 7 0.105 6.0 0x0 ShMt 45.5 175.0 st2 Room12-A h 916 72 7 0.134 6.0 0x0 ShMt 33.5 140.0 st2 Rcom13 h 30 64 12 0 0 0x0 ShMt 0 0 7.0 Room15 c 330 89 130 0.106 7.0 0x0 ShMt 45.0 175.0 st2 Room15-A c 330 89 130 0.134 7.0 0x0 ShMt 33.5 140.0 st2 Room15-B c 330 89 130 0.134 7.0 0x0 ShMt 23.5 150.0 st2 Room17 c 191 62 75 0 0 0x0 ShMt 0 0 Room17-A c 191 62 75 0 0 Oxo ShMt 0 0 Name Trunk Type Htg (cfm) Gig (cfm) Design FR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk st2 Peak AVF 412 405 0.105 742 9.8 8 x 10 ShtMetl (in) 2017 -Apr -0508:13:25 wrightSOft' Right -Suite® U nlversa1201717.0. 10 RSU20477 Page ...ware\Kadchner\F84B6 Ashland with basement.rup Calc =MJ8 House faces: N Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb14 Oxo 144 15 159.0 0.105 518 6.6 8x 5 ShMt rb11 Oxo 123 150 66.0 0.254 563 7.0 Ox 0 ShMt rb1 0x0 333 402 0 0 0 0 Ox 0 ShMt 2017 -Apr -0508:13:25 wrightSOft' Right -Suite® U nlversa1201717.0. 10 RSU20477 Page ...ware\Kadchner\F84B6 Ashland with basement.rup Calc =MJ8 House faces: N