Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 17-00025 - 572 Taurus Dr - Duplex ConsultationPermit Inspection Summary Permit Status of (Open) as of Report Date: 07/14/2017 1:42 pm Permit Details Permit Number: 17-00025 572 Taurus Dr - Duplex Consultation 572 Taurus Dr Consultation case Permit Issued Date: Permit Inspection Statistics Total Inspections Completed: Total Inspections Passed: Inspection Pass Rate Permit Inspection History *Refer to Individual Inspection Report for more Details 07/14/2017N/ADon AllenMechanical Inspector Consultation Building Inspection Type 01/26/2017NONCOMPLYTed DyeBuilding Inspector Consultation I was called to inspect and inform the home owners of the things that needed to be done to convert a previous mother in-law room that had been converted a bedroom into an apartment. Those items are as follows: -Obtain a conditional use permit. -Separate adjoining Walls and floors with a 1 hour separation. -Close of door between units off with studs and drywall or change door to a 20 minute door assembly. -Window needs to be operable. -Kitchen cabinets along with a kitchen sink is needed. -Electrical for a dryer/washer combo is needed. -Fire extinguisher is needed in both units kitchens. -A smoke detector is needed. -Park; there will need to be enough parking for 4 cars that do not extend into the side walk. -Check steps on deck to make sure that the riser is no more than 7-3/4" and that the treads are not less than 10". -Address indicating that there is an apartment also. Inspector Comments: Electrical Inspection Type 07/14/2017N/ABret StoddardElectrical Inspector Consultation Plumbing Inspection Type 07/14/2017N/ADon AllenPlumbing Inspector Consultation