Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 16-00594 - Consultation: Bring Duplex up to CodePermit Inspection Summary Permit Status of (Open) as of Report Date: 07/14/2017 10:53 am Permit Details Permit Number: 16-00594 Consultation: Bring Duplex up to Code 679 W Main Consultation case Permit Issued Date: Permit Inspection Statistics Total Inspections Completed: Total Inspections Passed: Inspection Pass Rate Permit Inspection History *Refer to Individual Inspection Report for more Details 08/31/2016COMPLETEDDon AllenMechanical Inspector Consultation Needs to separate the mechanical system from the 1 and 2 floorInspector Comments: Building Inspection Type 08/31/2016NONCOMPLYTed DyeBuilding Inspector Consultation Report for consult. Things discussed; --Separation between units including ceiling, walls between mechanical room on bottom unit and separation between garage and stair way. The ceiling in the bottom unit will need to be removed before appling 5/8" Type X drywall. --20 min doors from house to garage and on mechanical room. --Smoke detectors in bedroom with a Smoke/C.O. detector out side the bedroom doors. The smoke detectors should be tied together. The code states that if it is possible, the upstairs smoke detectors should also be tied together. --Egress window are needed in bedrooms. --Fire extinguisher needed in up and downstairs kitchens. Item that were not discussed; When installing the new stairs the requirements are; Treads a min. of 10", Risers have a max. height of 7--3/4", Headoom to be no less than 6-8", and the handrail has to be between 34"-38" running from the top tread to the bottom tread and then returning back to the wall on both top and bottom. --Parking; It is required that their be two (2) parking stalls for each unit. When applying for a permit include a site plan to be reviewed. -- If a bathroom window does not have 3 sq. ft. of window or there is no window in the bathroom, a exhaust fan is required. -- The Address Number needs to indicate that there is a unit in the basement. I Think that that covers most every thing If you have any Question please call. 208-716-1330 Thank You Ted Inspector Comments: Electrical Inspection Type 07/14/2017N/ABret StoddardElectrical Inspector Consultation Page 1 of 2 (Continued) Permit Details Permit Number: 16-00594 Consultation: Bring Duplex up to Code 679 W Main Consultation case Permit Status of (Open) as of Report Date: 07/14/2017 10:53 am Permit Inspection Summary Plumbing Inspection Type 08/31/2016COMPLETEDDon AllenPlumbing Inspector Consultation Needs to separate the water system from the 1 and 2 floor. need to be able to shut one off with out the author Inspector Comments: Page 2 of 2