HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00525 - 686 Hillside Dr - SFRPermit
Inspection
Summary
Permit Status of (Expired) as of Report Date: 07/11/2017 3:41 pm
Permit Details Permit Number: 12-00525
686 Hillside Drive - SFR
686 Hillside Drive
Building - Single Family Residence
Permit Issued Date: 08/15/2014
Permit Inspection Statistics
20Total Inspections Completed:
17Total Inspections Passed:
Inspection Pass Rate
85.00%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
11/29/2012PassQuinton OwensResidential Footing Inspection
2 #4's cont. supported. Front setbacks? reviewed w/ Val.Inspector Comments:
12/04/2012PassQuinton OwensFoundation Inspection
#4's 2' oc each w/ 2 in top 12" per city ordinance.Inspector Comments:
03/19/2013FailQuinton OwensResidential Framing/Structure Inspection
Hold downs required below side of kitchen corner windows. Smoke det. needed
on ceiling at bottom of stairs in bsmt, blocking on braced wall panel between
door and window in basement.
Inspector Comments:
04/05/2013PassTed DyeResidential Sheetrock/Drywall Inspection
Access will be required for the Jucuzzi OK going to access through cabinet garage
sheetrock OK Main floor OK Basement; 2 bedrooms and bearing wall and utility
are OK ***No other drywall installed in basement *** Fireplace is not covered.
talked to them and it is going to have backer board with rock on it.
Inspector Comments:
04/11/2013PassTed DyeResidential Insulation Inspection
insulation inspection was never called for looked at walls in various locations and
insulation looked good. cellulose insulation used. windows and doors had
insulation around them baffles were in place. insulation certificate will be
mounted on electrical box.
Inspector Comments:
04/11/2013PassQuinton OwensResidential Framing/Structure Inspection
Not sure of date but a follow up inspection was done on framing items before
drywall approved. (based on memory only - no ticket found)
Inspector Comments:
07/09/2013PassTed DyeSidewalk Inspection
07/11/2013FailTed DyeResidential Building Final
Garage/house separation requires 5/8" TYPE X on garage side (ceiling and walls).
Handrails too short to bonus room. CO det. required just outside bedrooms.
Anchor water heaters. Guardrails on deck not done (doors disabled).
Inspector Comments:
08/15/2014PassTed DyeResidential Building Final
Page 1 of 3
(Continued)
Permit Details Permit Number: 12-00525
686 Hillside Drive - SFR
686 Hillside Drive
Building - Single Family Residence
Permit Status of (Expired) as of Report Date: 07/11/2017 3:41 pm
Permit
Inspection
Summary
Electrical Inspection Type
03/15/2013PassBret StoddardResidential Electrical Service Inspection
Approved to be energized for permanent power-inspected the service on the
rough-in inspection therefore no separate inspection ticket was written for the
service only.
Inspector Comments:
03/15/2013PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
Approved for cover everywhere except as noted-unfinished living room and one
bathroom on the west side in the basement. Inspected the service on this
inspection.
Inspector Comments:
07/11/2013FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Closet light in the basement bedroom to close to shelving, outside can under the
deck not damp location rated, WR receptacle needed on the west side of the
garage, GFCI protection needed in the mech. room basement, wire in
underground garage not terminated, no light in the bedroom upstairs, no A/C
unit is installed-only disconnect(30A OCPD), no under cabinet lights installed in
kitchen, call for a re-inspect when ready.
Inspector Comments:
07/12/2013PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Approved for a final and C.O.-unfinished living room(outside walls wired),
bathroom, and 1 bedroom(wired) on the north side, closet light in the basement
bedroom blanked also the switch, light under deck is moved to the wall, no A/C
unit installed, kitchen under cabinet lights not installed.
Inspector Comments:
Mechanical Inspection Type
03/12/2013PassQuinton OwensGas Pressure Test
Low Pressure side 1(south): 25.5 psi for 20 min - Dryer (2), stove, garage, Patio.
Low pressure side 2 (north): 25 psi for 20 min - Fireplace (2), W.H., Furnace.
Med. pressure side: 60 psi for 30 min.
Inspector Comments:
03/12/2013PassQuinton OwensHVAC Rough-in
Electricians to seal penetrations in RA plenums. Drop supply vent in bsmt NE
corner closet to new ceiling. Specification on South end Maxitrol pressure
regulator (not vented, no label)
Inspector Comments:
07/12/2013PassQuinton OwensHVAC Final Inspection
Maxitrol regulator position corrected.Inspector Comments:
Page 2 of 3
(Continued)
Permit Details Permit Number: 12-00525
686 Hillside Drive - SFR
686 Hillside Drive
Building - Single Family Residence
Permit Status of (Expired) as of Report Date: 07/11/2017 3:41 pm
Permit
Inspection
Summary
Plumbing Inspection Type
12/11/2012PassDon AllenPlumbing Underground Inspection
All good to cover.Inspector Comments:
02/26/2013PassDon AllenPlumbing Rough-in
All good to cover rough inInspector Comments:
03/14/2013PassDon AllenPlumbing Water
Chris Scott passed it.Inspector Comments:
03/15/2013PassDon AllenPlumbing Sewer
All good to cover.Inspector Comments:
07/11/2013PassDon AllenPlumbing Final Inspection
All good for the c/oInspector Comments:
Page 3 of 3