HomeMy WebLinkAboutINSPECTION SUMMARY - 12-00525 - 686 Hillside Dr - SFRPermit Inspection Summary Permit Status of (Expired) as of Report Date: 07/11/2017 3:41 pm Permit Details Permit Number: 12-00525 686 Hillside Drive - SFR 686 Hillside Drive Building - Single Family Residence Permit Issued Date: 08/15/2014 Permit Inspection Statistics 20Total Inspections Completed: 17Total Inspections Passed: Inspection Pass Rate 85.00% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 11/29/2012PassQuinton OwensResidential Footing Inspection 2 #4's cont. supported. Front setbacks? reviewed w/ Val.Inspector Comments: 12/04/2012PassQuinton OwensFoundation Inspection #4's 2' oc each w/ 2 in top 12" per city ordinance.Inspector Comments: 03/19/2013FailQuinton OwensResidential Framing/Structure Inspection Hold downs required below side of kitchen corner windows. Smoke det. needed on ceiling at bottom of stairs in bsmt, blocking on braced wall panel between door and window in basement. Inspector Comments: 04/05/2013PassTed DyeResidential Sheetrock/Drywall Inspection Access will be required for the Jucuzzi OK going to access through cabinet garage sheetrock OK Main floor OK Basement; 2 bedrooms and bearing wall and utility are OK ***No other drywall installed in basement *** Fireplace is not covered. talked to them and it is going to have backer board with rock on it. Inspector Comments: 04/11/2013PassTed DyeResidential Insulation Inspection insulation inspection was never called for looked at walls in various locations and insulation looked good. cellulose insulation used. windows and doors had insulation around them baffles were in place. insulation certificate will be mounted on electrical box. Inspector Comments: 04/11/2013PassQuinton OwensResidential Framing/Structure Inspection Not sure of date but a follow up inspection was done on framing items before drywall approved. (based on memory only - no ticket found) Inspector Comments: 07/09/2013PassTed DyeSidewalk Inspection 07/11/2013FailTed DyeResidential Building Final Garage/house separation requires 5/8" TYPE X on garage side (ceiling and walls). Handrails too short to bonus room. CO det. required just outside bedrooms. Anchor water heaters. Guardrails on deck not done (doors disabled). Inspector Comments: 08/15/2014PassTed DyeResidential Building Final Page 1 of 3 (Continued) Permit Details Permit Number: 12-00525 686 Hillside Drive - SFR 686 Hillside Drive Building - Single Family Residence Permit Status of (Expired) as of Report Date: 07/11/2017 3:41 pm Permit Inspection Summary Electrical Inspection Type 03/15/2013PassBret StoddardResidential Electrical Service Inspection Approved to be energized for permanent power-inspected the service on the rough-in inspection therefore no separate inspection ticket was written for the service only. Inspector Comments: 03/15/2013PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover everywhere except as noted-unfinished living room and one bathroom on the west side in the basement. Inspected the service on this inspection. Inspector Comments: 07/11/2013FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Closet light in the basement bedroom to close to shelving, outside can under the deck not damp location rated, WR receptacle needed on the west side of the garage, GFCI protection needed in the mech. room basement, wire in underground garage not terminated, no light in the bedroom upstairs, no A/C unit is installed-only disconnect(30A OCPD), no under cabinet lights installed in kitchen, call for a re-inspect when ready. Inspector Comments: 07/12/2013PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final and C.O.-unfinished living room(outside walls wired), bathroom, and 1 bedroom(wired) on the north side, closet light in the basement bedroom blanked also the switch, light under deck is moved to the wall, no A/C unit installed, kitchen under cabinet lights not installed. Inspector Comments: Mechanical Inspection Type 03/12/2013PassQuinton OwensGas Pressure Test Low Pressure side 1(south): 25.5 psi for 20 min - Dryer (2), stove, garage, Patio. Low pressure side 2 (north): 25 psi for 20 min - Fireplace (2), W.H., Furnace. Med. pressure side: 60 psi for 30 min. Inspector Comments: 03/12/2013PassQuinton OwensHVAC Rough-in Electricians to seal penetrations in RA plenums. Drop supply vent in bsmt NE corner closet to new ceiling. Specification on South end Maxitrol pressure regulator (not vented, no label) Inspector Comments: 07/12/2013PassQuinton OwensHVAC Final Inspection Maxitrol regulator position corrected.Inspector Comments: Page 2 of 3 (Continued) Permit Details Permit Number: 12-00525 686 Hillside Drive - SFR 686 Hillside Drive Building - Single Family Residence Permit Status of (Expired) as of Report Date: 07/11/2017 3:41 pm Permit Inspection Summary Plumbing Inspection Type 12/11/2012PassDon AllenPlumbing Underground Inspection All good to cover.Inspector Comments: 02/26/2013PassDon AllenPlumbing Rough-in All good to cover rough inInspector Comments: 03/14/2013PassDon AllenPlumbing Water Chris Scott passed it.Inspector Comments: 03/15/2013PassDon AllenPlumbing Sewer All good to cover.Inspector Comments: 07/11/2013PassDon AllenPlumbing Final Inspection All good for the c/oInspector Comments: Page 3 of 3