Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 16-00279 - The Cottages Bldg 2 (Units 5-8) - MFRPermit Inspection Summary Permit Status of (Issue) as of Report Date: 07/07/2017 10:45 am Permit Details Permit Number: 16-00279 The Cottages Bldg 2 (Units 5-8) - MFR 435 W 1st N Bldg 2 - Units 5-8 Multi-Family Residential Permit Issued Date: 05/26/2016 Permit Inspection Statistics 25Total Inspections Completed: 22Total Inspections Passed: Inspection Pass Rate 88.00% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 05/26/2016PassTed DyeFoundation Inspection 06/07/2016PassTed DyeCommercial Footing Inspection 06/07/2016PassTed DyeFoundation Inspection 07/19/2016PassTed DyeFoundation Inspection Porch caps, backed filled with rebar mat.Inspector Comments: 08/18/2016FailTed DyeCommercial Framing/Structure Inspection Framing also failed because sheeting inspection had not been called for or passed. Sheeting inspection has not been passed. I will need to look at nailing pattens. Inspector Comments: 08/18/2016PassTed DyeSheeting The sheeting that missed being nailed to the studs have been marked on the studs with green paint. I will need to look at the nailing patterns on the sheeting. Call for reinspection. Inspector Comments: 08/20/2016PassTed DyeSheeting 08/20/2016PassTed DyeCommercial Framing/Structure Inspection 08/22/2016PassTed DyeResidential Insulation Inspection 08/26/2016PassTed DyeResidential Sheetrock/Drywall Inspection Unit inspected were Units 1, 2 and 3Inspector Comments: 09/13/2016PassTed DyeResidential Sheetrock/Drywall Inspection 12/12/2016PassTed DyeResidential Sheetrock/Drywall Inspection 12/22/2016PassTed DyeCommercial Building Final Unit # 5 of building #2; Approved for final C.O. Only. All other units in building #2 will still need to be inspected. Inspector Comments: 03/01/2017FailTed DyeResidential Building Final The handicap handrail on the side of the toilet need to extend out 54" from the back wall. That would give a 1' gap between the back wall and the starting point of the bar(using a 42" bar). Inspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 16-00279 The Cottages Bldg 2 (Units 5-8) - MFR 435 W 1st N Bldg 2 - Units 5-8 Multi-Family Residential Permit Status of (Issue) as of Report Date: 07/07/2017 10:45 am Permit Inspection Summary 03/31/2017PassTed DyeResidential Building Final Those bedrooms that had fans in them had the fans removed because they were to close to the smoke detectors. Inspector Comments: Electrical Inspection Type 08/17/2016PassBret StoddardElectrical Rough-in SFR-A,R,B, MFR-A,R 10/04/2016PassBret StoddardResidential Electrical Service Inspection 12/22/2016PARTPASSBret StoddardResidential Electrical Final Inspection 02/28/2017PassBret StoddardResidential Electrical Final Inspection Mechanical Inspection Type 08/11/2016PassDon AllenHVAC Rough-in Good to cover the mechanical rough inInspector Comments: 01/03/2017PassDon AllenHVAC Final Inspection Good for the C/O on the apt. 5-8Inspector Comments: Plumbing Inspection Type 06/08/2016PassDon AllenPlumbing Underground Inspection 08/16/2016PassDon AllenPlumbing Rough-in Good to cover the plumbing rough inInspector Comments: 12/23/2016PassDon AllenPlumbing Final Inspection Good on the plumbing in apt. 5 onlyInspector Comments: 01/03/2017PassDon AllenPlumbing Final Inspection Page 2 of 2