HomeMy WebLinkAboutINSPECTION SUMMARY - 16-00279 - The Cottages Bldg 2 (Units 5-8) - MFRPermit
Inspection
Summary
Permit Status of (Issue) as of Report Date: 07/07/2017 10:45 am
Permit Details Permit Number: 16-00279
The Cottages Bldg 2 (Units 5-8) - MFR
435 W 1st N Bldg 2 - Units 5-8
Multi-Family Residential
Permit Issued Date: 05/26/2016
Permit Inspection Statistics
25Total Inspections Completed:
22Total Inspections Passed:
Inspection Pass Rate
88.00%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
05/26/2016PassTed DyeFoundation Inspection
06/07/2016PassTed DyeCommercial Footing Inspection
06/07/2016PassTed DyeFoundation Inspection
07/19/2016PassTed DyeFoundation Inspection
Porch caps, backed filled with rebar mat.Inspector Comments:
08/18/2016FailTed DyeCommercial Framing/Structure Inspection
Framing also failed because sheeting inspection had not been called for or
passed.
Sheeting inspection has not been passed. I will need to look at nailing pattens.
Inspector Comments:
08/18/2016PassTed DyeSheeting
The sheeting that missed being nailed to the studs have been
marked on the studs with green paint.
I will need to look at the nailing patterns on the sheeting.
Call for reinspection.
Inspector Comments:
08/20/2016PassTed DyeSheeting
08/20/2016PassTed DyeCommercial Framing/Structure Inspection
08/22/2016PassTed DyeResidential Insulation Inspection
08/26/2016PassTed DyeResidential Sheetrock/Drywall Inspection
Unit inspected were Units 1, 2 and 3Inspector Comments:
09/13/2016PassTed DyeResidential Sheetrock/Drywall Inspection
12/12/2016PassTed DyeResidential Sheetrock/Drywall Inspection
12/22/2016PassTed DyeCommercial Building Final
Unit # 5 of building #2; Approved for final C.O. Only.
All other units in building #2 will still need to be inspected.
Inspector Comments:
03/01/2017FailTed DyeResidential Building Final
The handicap handrail on the side of the toilet need to extend out 54" from the
back wall.
That would give a 1' gap between the back wall and the starting point of the
bar(using a 42" bar).
Inspector Comments:
Page 1 of 2
(Continued)
Permit Details Permit Number: 16-00279
The Cottages Bldg 2 (Units 5-8) - MFR
435 W 1st N Bldg 2 - Units 5-8
Multi-Family Residential
Permit Status of (Issue) as of Report Date: 07/07/2017 10:45 am
Permit
Inspection
Summary
03/31/2017PassTed DyeResidential Building Final
Those bedrooms that had fans in them had the fans removed because they were
to close to the smoke detectors.
Inspector Comments:
Electrical Inspection Type
08/17/2016PassBret StoddardElectrical Rough-in SFR-A,R,B, MFR-A,R
10/04/2016PassBret StoddardResidential Electrical Service Inspection
12/22/2016PARTPASSBret StoddardResidential Electrical Final Inspection
02/28/2017PassBret StoddardResidential Electrical Final Inspection
Mechanical Inspection Type
08/11/2016PassDon AllenHVAC Rough-in
Good to cover the mechanical rough inInspector Comments:
01/03/2017PassDon AllenHVAC Final Inspection
Good for the C/O on the apt. 5-8Inspector Comments:
Plumbing Inspection Type
06/08/2016PassDon AllenPlumbing Underground Inspection
08/16/2016PassDon AllenPlumbing Rough-in
Good to cover the plumbing rough inInspector Comments:
12/23/2016PassDon AllenPlumbing Final Inspection
Good on the plumbing in apt. 5 onlyInspector Comments:
01/03/2017PassDon AllenPlumbing Final Inspection
Page 2 of 2