Loading...
HomeMy WebLinkAboutPLANS - 17-00370 - BYUI - Snow Building Teaching StudiosLOCATION MAP ELIZA R. SNOW BUILDING UPPER LEVEL PIANO LAB 233 PROJECT LOCATION ELIZA R. SNOW a BUILDING @2017 BYU-IDAHO 525 SOUTH CENTER REXXBURG, IDAHO 833 60ET ��SED ARCH U N SNO 233 TEACHING STUDIOS ALK. AR- 8 84 sr Of,o� DOCUMENT STATUS STATUS DATE PRELIMINARY 05/08/17 REVISED PRELIMINARY 05/10/17 REVISED PRELIMINARY 05/12/17 REVISED PRELIMINARY 5/23/17 PLAN DISTRIBUTION APPROVAL SIGNATURES REVPRELIMINARY 8/12/17 BID DOCUMENTS 8/28/17 DOCUM REVISION SCHEDULE ■ UNIV. OPERATIONS MANAGING DIRECTOR - WAYNE CLARK (496-2510) N0. DESCRIPTION DATE ■ DESIGN & CONSTRUCTION DIRECTOR - RULON NIELSEN (496-2660) ■ CAMPUS ARCHITECT - JEDD WALKER (496-2663) ■ FACILITIES MGMT. SERVICES DIRECTOR - DOUG WATSON (496-2600) ■ FACILITIES MGMT. OP. DIRECTOR - KYLE WILLIAMS (496-2520) KYLE WILLIAMS DATE DIRECTOR, FACILITIES MANAGEMENT OPERATIONS ■ UNIV. OP. BUSINESS SERVICES DIRECTOR - MARIE WELLS (496-2501) ■ CARPENTRY SERVICES SUPERVISOR - GREG EDWARDS (496-2530) ■ ELECTRICAL SERVICES SUPERVISOR - STEVE PRICE (496-2540) ■ HVAC SERVICES SUPERVISOR - SAM MERRICK (496-2570) ■ HVAC AUTOMATION TECHNICIAN - BILL SCHIERS (496-2431) DRAWN BY: JEDD A. WALKER CHECKED BY: JEDD A. WALKER PROJECT NAME: SNO 233 TEACHING RULON NIELSEN DATE DIRECTOR, DESIGN AND CONSTRUCTION ■ MECHANICAL OPERATIONS SUPERVISOR - CRAIG FORBUSH (496-2590) STUDIOS ■ MAINTENANCE SERVICES SUPERVISOR - DOUG SORENSEN (496-2550) ■ AUXILIARY MAINTENANCE SUPERVISOR - CODY CLARK (496-2516) JEDD WALKER DATE ■ SIGN TECHNICIAN - DARRELL HOLM (496-2622) ■ SAFETY OFFICER - ERIC HARMSTON (496-3053) CAMPUS ARCHITECT ■ FIRE PROTECTION OFFICER - BYRON GILBERT (496-3056) ■ FACILITY/FIRE SYSTEMS TECHNICIAN - THOMAS MOORE (496-3058) PROJECT NO. 11285 ■ IT INFRASTRUCTURE DIRECTOR - SHAUN SESSIONS (496-7099) ■ NETWORK ENGINEER - TRAVIS WILLIAMS (496-7097) ■ END USER TECHNOLOGIES - DAN PETERSON (496-7127) 11 CLASSROOM TECHNOLOGY DIRECTOR - NYKOLUS VAIL (496-7071) SHEET NAME: COVER SHEET CHAD PRICE DATE DIRECTOR, SPACE MANAGEMENT &PLANNING ■ TELEPHONES - SHAUN SESSIONS (496-7099) ■ PURCHASING SPECIALIST - NATHAN CALL (496-2323) ■ SPACE MGMT. & PLANNING DIRECTOR - CHAD PRICE (496-1260) ■ SUPPORT SERVICES SUPERVISOR - STEVE BUNNELL (496-3000) ■ REQUESTER - DIANE SOELBERG (496-4973) DIANE SOELBERG DATE DEPARTMENT CHAIR, MUSIC ■ REQUESTER - RICHARD CLIFFORD (496-4829) SHEET NUMBER: i G001 RICHARD CLIFFORD DATE o COLLEGE DEAN, PERFORMING & VISUAL ARTS D 1 of 23 ABBREVIATIONS SYMBOLS SHEET INDEX SHEET NO. SHEET NAME A.F.F.: ABOVE FINISHED FLOOR ALUM: ALUMINUM SIM BYU i 1. GENERAL G001 COVER SHEET ASC: ABOVE SUSPENDED CEILING CG: CORNER GUARD CJ: CORNER JOINT 1 DETAIL REFERENCE A101 G002 GENERAL INFORMATION 4. ARCHITECTURAL DEMOLITIONIDAHO AD101 DEMOLITION FLOOR PLAN CL: CENTERLINE CLR: CLEAR 1 SIM AD102 DEMOLITION REFLECTED CEILING PLAN CMU: CONCRETE MASONRY UNIT A101 1 INTERIOR ELEVATION REFERENCE AD401 INTERIOR DEMOLITION ELEVATIONS CO: CLEANOUT COL: COLUMN CONC: CONCRETE CONST: CONSTRUCTION CPT: CARPET DEMO: DEMLISH, DEMOLITION DF: DRINKING FOUNTAIN DIA: DIAMETER EJ: EXPANSION DIAMETER JOINT ELEV: ELEVATIONS F.F.: FINISHED FLOORSECTION F.V.: FIELVE VERIFY FEC: FIRE EXTINGUISHER CABINET 1 Ref 1� Al1 1� INTERIOR ELEVATION REFERENCE 1 Ref 1 SIM REFERENCE A101 5. ARCHITECTURAL CONSTRUCTION @2017 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460 AR�,y/r v ALKER AR -9840 4 AE101 CONSTRUCTION FLOOR PLAN AE102 CONSTRUCTION REFLECTED CEILING PLAN AE103 ROOM RENUMBERING FLOOR PLAN AE401 INTERIOR CONSTRUCTOIN ELEVATIONS AE402 INTERIOR CONSTRUCTION ELEVATIONS AE501 CONSTRUCTION DETAILS AE502 CONSTRUCTION DETAILS AE601 DOOR, ROOM, FLOOR, BASE, WALL, & CEILING SCHEDULES AE602 FIXTURE AND EQUIPMENT SCHEDULE A1101 ARCHITECTURAL INTERIORS FURNITURE PLAN - 233 & 234 A1102 ARCHITECTURAL INTERIORS FURNITURE PLAN - 235 & 236 GA: GUAGE GALV: GALVANIZED 1 Ref �r�4 v A1401 ARCHITECTURAL INTERIORS ELEVATIONS - 233 & 234 GB: GRAB BAR GYP BD: GYPSUM BOARD HM: HOLLOW METAL A( A101 EXTTERIOR ELEVATION REFERENCE AI402 ARCHITECTURAL INTERIORS ELEVATIONS - 235 & 236 AI601 ARCHITECTURAL INTERIORS FURNITURE SCHEDULE - A1901 ARCHITECTURAL INTERIORS 3D REPRESENTATIONS OFFICE 233 IBC: 2012 INTERNATIONAL BUILDING CODE INSUL: INSULATION MIN: MINIMUM N DOCUMENT STATUS TE A1902 ARCHITECTURAL INTERIORS 3D REPRESENTATIONS PRELIMINARYTATUS 05/0817 REVISED PRELIMINARY 05/10/17 O.C.: ON CENTER OFFICE 234 REVISED PRELIMINARY 05/12/17 OH: OPPOSITE HAND OP/OI: OWNER PROVIDE/OWNER INSTALLED OP/Cl: OWNER PROVIDED/CONTRACTOR INSTALLED CP/CI: CONTRACTOR PROVIDED/CONTRACTOR INSTALLED OPP: OPPOSITE P LAM: PLATIC LAMINATE NORTH ARROW ? REFERENCE NOTE AI903 ARCHITECTURAL INTERIORS 35/ REPRESENTATIONS OFFICE 235 REVISED PRELIMINARY 5/23/17 REVISED PRELIMINARY 6/12/17 A1904 ARCHITECTURAL INTERIORS 3D REPRESENTATIONS OFFICE 236 BID DOCUMENTS 6/26/17 REVISION SCHEDULE 6. MECHANICAL NO. DESCRIPTION DATE M101 DEMOLITION / MACHANICAL FLOOR PLAN REF: REFERENCE SIM: SIMILAR DF1 1F1FURNITURE TAG M201 DEMOLITION / MECHANICAL FLOOR PLAN S.S. STAINLESS STEEL SPECS: SPECIFICATIONS M202 DEMOLITION /MECHANICAL FLOOR PLAN 7. ELECTRICAL GENERAL T.O.C.: TOP OF CONCRETE TP: TOILET PAPER DISPENSER TYP: TYPICAL VIF: VERIFY IN FIELD 1 i EQUIPMENT TAG 1i ACCESSORY TAG 1t WINDOW TAG EGO01 ELECTRICAL COVER SHEET DRAWN BY: JEDD A. WALKER CHECKED BY: JEDD A. WALKER EGO02 LEVEL 2 - PARTIAL FLOOR PLAN PROJECT NAME: SNO 233 TEACHING STUDIOS 8. ELECTRICAL DEMOLITION ED101 I EXISTING PLAN - ELECTRICAL 9. ELECTRICAL CONSTRUCTION EE101 LIGHTING PLAN 101 DOOR TAG EE102 POWER AND SPECIAL SYSTEMS PLAN 1 I WALL TAG PROJECT NO. 11285 SHEET NAME: Room name GENERAL 101 ROOM TAG INFORMATION REVISION TAG ELEVATION MARKER SHEET NUMBER: G®®2 a Y a 2 of 23 23 82 29.D1 -- - - - 02 41 OO.A8 -- 2 AD401 r3l I - -- - -- � I 1 10 14 OO.C2 DEMOLITION FLOOR PLAN 1/411 = 1 '-0" n 06 41 13.D1 02 41 OO.C42 3 AD401 26 05 05.D1 c� AD401 1 D234 KEYNOTE LEGEND 02 41 OO.A6 SALVAGE ITEM, RETURN TO OWNER 02 41 OO.A8 DEMOLISH - EXISTING ELECTRICAL ITEM 02 41 OO.A9 02 41 OO.C42 DEMOLISH - EXISTING THERMOSTAT CARPET TO BE REMOVED 06 41 13.D1 DEMOLISH - SHELF, SUPPORTS, AND STANDARDS 10 14 OO.C2 MODIFY FACE PLATE OF EXISTING ROOM NAME / NUMBER PLAQUE TO ACCOMMODATE NEW NAMING AND NUMBERING 10 28 OO.D1 DEMOLISH - HAND SANITIZER DISPENSER 11 52 13.D1 DEMOLISH - PROJECTION SCREEN 23 82 29.D1 DEMOLISH - RADIATOR 26 05 05.D1 DEMOLISH - UTILITY POLE - COORDINATE WITH ELECTRICAL 27 24 23.D1 DEMOLISH - WALL -MOUNTED SPEAKER 27 53 13.D1 DEMOLISH - WALL -MOUNTED CLASSROOM CLOCK 28 31 63.D1 DEMOLISH - FIRE ALARM HORN AND STROBE LIGHT 27 24 23.D1 02 41 OO.A6 it IL Fj CAD401 4 I; N I� J� 'I GENERAL NOTES 260505.D1 �' 1. ALL EXISTING CONSTRUCTION IS TO REMAIN UNLESS SPECIFICALLY 27 24 23.D1 NOTED OTHERWISE. ALL EXISTING TO REMAIN ITEMS THAT ARE 28 31 63.D1 i DAMAGED BY DEMOLITION AND/OR CONSTRUCTION ACTIVITIES SHALL 27 53 13.D1 / i �' BE REPAIRED OR REPLACED TO THE ' i OWNER'S SATISFACTION. r I' 2. FIELD VERIFY ALL EXISTING CONDITIONS INCLUDING BUT NOT D235 (� D236 feu_ LIMITED TO DIMENSIONS AND --- QUANTITIES. 02 41 OO.A9'--10 14 OO.C2 3. REMOVE AND STORE ALL WIRELESS ACCESS POINTS FOR THE DURATION OF ALL CONSTRUCTION ACTIVITIES. MAINTAIN CABLE IN PLACE. REINSTALL WIRELESS ACCESS POINTS UPON COMPLETION OF THE PROJECT. ©2017 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460 DOCUMENT STATUS STATUS DATE PRELIMINARY 05/08/17 REVISED PRELIMINARY 05/10/17 REVISED PRELIMINARY 05/12/17 REVISED PRELIMINARY 5/23/17 REVISED PRELIMINARY 6/12/17 BID DOCUMENTS 6/26/17 REVISION SCHEDULE NO. DESCRIPTION DATE DRAWN BY: JEDD A. WALKER CHECKED BY: JEDD A. WALKER PROJECT NAME: SNO 233 TEACHING STUDIOS PROJECT NO. 11285 SHEET NAME: DEMOLITION FLOOR PLAN SHEET NUMBER: AD101 3 OF 23 09 53 23.D1 23 37 13.D2 21 13 13.D1 23 37 13.D2 KEYNOTE LEGEND 09 53 23.D1 DEMOLISH - SUSPENDED ACOUSTICAL TILE CEILING PROJECT NAME: SYSTEM I 27 24 23.D1 11 52 13.D1 DEMOLISH - PROJECTION SCREEN TO REMAIN UNLESS SPECIFICALLY 11 52 16.D1 DEMOLISH - PROJECTOR 21 13 13.D1 DEMOLISH - SEMI -RECESSED FIRE SPRINKLER HEAD 26 05 05.D2 23 37 13.D1 DEMOLISH - SUPPLY AIR DIFFUSER 23 37 .D2 JaEMOLISI- ETURNM GRILL OWNER'S SATISFACTION. 23-�7 13. SAL - SU AIR D ER SHEET NAME: 26 05 05.D1 DEMOLISH - UTILITY POLE - COORDINATE WITH CONDITIONS INCLUDING BUT NOT REFLECTED TRIC 5 CEILING PLAN 3. REMOVE AND STORE ALL 2721 33.S1 SALVAGE - WIRELESS ACCESS POINT - PRESERVE CABLE THE DURATION OF ALL ABOVE CEILING FOR REINSTALLATION (� 7 24 ISH - -MOUNIT6 SPE i� ! DRAWN BY: JEDD A. WALKER CHECKED BY: JEDD A. WALKER GENERAL NOTES PROJECT NAME: SNO 233 TEACHING I 27 24 23.D1 1. ALL EXISTING CONSTRUCTION IS - TO REMAIN UNLESS SPECIFICALLY NOTED OTHERWISE. ALL EXISTING 211313.D1 115213.D1 27 24 23.D1 DEMOLITION REFLECTED CEILING PLAN 1/411 = 1'-0'1 ©2017 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460 DOCUMENT STATUS STATUS DATE PRELIMINARY 05/08/1 REVISED PRELIMINARY 05/10/1 REVISED PRELIMINARY 05/12/1 REVISED PRELIMINARY 5/23/17 REVISED PRELIMINARY 6/12/17 NBID DOCUMENTS 6/26/1 REVISION SCHEDULE NO. DESCRIPTION DATE 1 ADDRESS COMMENTS 6/19/17 DRAWN BY: JEDD A. WALKER CHECKED BY: JEDD A. WALKER GENERAL NOTES PROJECT NAME: SNO 233 TEACHING 2605 05.D2 1. ALL EXISTING CONSTRUCTION IS STUDIOS TO REMAIN UNLESS SPECIFICALLY NOTED OTHERWISE. ALL EXISTING TO REMAIN ITEMS THAT ARE 26 05 05.D2 ^ CONSTRUCTION ACTIVITIES SHALL BE REPAIRED OR REPLACED TO THE PROJECT N0. 11285 OWNER'S SATISFACTION. II SHEET NAME: 2. FIELD VERIFY ALL EXISTING DEMOLITION CONDITIONS INCLUDING BUT NOT REFLECTED LIMITED TO DIMENSIONS AND QUANTITIES. CEILING PLAN 3. REMOVE AND STORE ALL WIRELESS ACCESS POINTS FOR THE DURATION OF ALL (� SHEET NUMBER: 21 1313.D1 AD102 POINTS UPON COMPLETION OF THE 21 1313.D1 4 of 23 21 13 13.D1 26 05 05.D2 23 37 13.D1 21 13 13.D1 II /� (\ II 23 37 13.S1 23 37 13.S1 -_ A F 71 211313.D1 233713.S1 11 52 c 16.D1 233713.D1 /II /II 21 13 13.D1 - Fl 26 05 05.D2 26 05 05.D2 23371 IL 26 05 05.D1 21 13 13.D1 26 05 05.D2 211313.D1 115213.D1 27 24 23.D1 DEMOLITION REFLECTED CEILING PLAN 1/411 = 1'-0'1 ©2017 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460 DOCUMENT STATUS STATUS DATE PRELIMINARY 05/08/1 REVISED PRELIMINARY 05/10/1 REVISED PRELIMINARY 05/12/1 REVISED PRELIMINARY 5/23/17 REVISED PRELIMINARY 6/12/17 NBID DOCUMENTS 6/26/1 REVISION SCHEDULE NO. DESCRIPTION DATE 1 ADDRESS COMMENTS 6/19/17 DRAWN BY: JEDD A. WALKER CHECKED BY: JEDD A. WALKER GENERAL NOTES PROJECT NAME: SNO 233 TEACHING 1. ALL EXISTING CONSTRUCTION IS STUDIOS TO REMAIN UNLESS SPECIFICALLY NOTED OTHERWISE. ALL EXISTING TO REMAIN ITEMS THAT ARE DAMAGED BY DEMOLITION AND/OR CONSTRUCTION ACTIVITIES SHALL BE REPAIRED OR REPLACED TO THE PROJECT N0. 11285 OWNER'S SATISFACTION. SHEET NAME: 2. FIELD VERIFY ALL EXISTING DEMOLITION CONDITIONS INCLUDING BUT NOT REFLECTED LIMITED TO DIMENSIONS AND QUANTITIES. CEILING PLAN 3. REMOVE AND STORE ALL WIRELESS ACCESS POINTS FOR THE DURATION OF ALL CONSTRUCTION ACTIVITIES. SHEET NUMBER: MAINTAIN CABLE IN PLACE. REINSTALL WIRELESS ACCESS AD102 POINTS UPON COMPLETION OF THE PROJECT. 4 of 23 06 41 13.D1 11 52 13.D1 27 24 23.D126 05 05.D1 27 24 23.D1 I F--- I- ! I I II I j I II it I I II I I 02 41 OO.A6 I I I III II I { r L -1 L ! I I II II I 11- I I � I I II II 02 41 OO.C45 EAST DEMOLITION ELEVATION = 1 '-0" 06 41 13.D1 f--�'02 41 OO.C45 02 41 OO.A8 23 82 29. D 1 C __j o o ❑ c I a 2 WEST DEMOLITION ELEVATION 1/4= 1 0 r r u r 06 41 13.D1 27 24 23.D1 Ep ARC��rF --------------= - - - - - - -T-- - - - - - -� � _- - - - - - - - - T__ 1 ' AR- 84084 4LP 4 j 02 41 OO.A6 I rq F �pt►'r I ! OD= o I DOCUMENT STATUS STATUS DATE 82 29.D1 02 41 OO.C45 23 ' - _ �____.. !- _ I PRELIMINARY 05/08/17 C3 ELI E3 I � REVISED PRELIMINARY 05/10/17 REVISED PRELIMINARY 05/12/17 REVISED PRELIMINARY 5/23/17 - - - - - - - - - - - - - - - - - - _ - - _�_ REVISED PRELIMINARY 6/12/17 BID DOCUMENTS 6/26/17 REVISION SCHEDULE 3 NORTH DEMOLITION ELEVATION NO. DESCRIPTION DATE 27 53 13.D1 11 52 13.D1 28 31 63.D1 28 31 63.D1 DRAWN BY: JEDD A. WALKER CHECKED BY: JEDD A. WALKER 27 24 23.D1 26 05 05.D1 10 28 OO.D1 PROJECT NAME: --- - -- - -- ----� -- SNO 233 TEACHING STUDIOS --------------- 1I PROJECT N0. 11285 o I I °I) fl ° ° SHEET NAME: 024100.A9 ;I I� II I` INTERIOR DEMOLITION ® I I �_ �, ❑ o ELEVATIONS j I II � I II 02 41 OO.C45 SOUTH DEMOLITION ELEVATION SHEET NUMBER: AD401 5 of 23 KEYNOTE LEGEND 02 41 OO.A6 SALVAGE ITEM, RETURN TO OWNER 02 41 OO.A8 DEMOLISH - EXISTING ELECTRICAL ITEM 02 41 OO.A9 DEMOLISH - EXISTING THERMOSTAT 02 41 OO.C45 CARPET BASE TO BE REMOVED 06 41 13.D1 DEMOLISH - SHELF, SUPPORTS, AND STANDARDS , 10 28 OO.D1 DEMOLISH - HAND SANITIZER DISPENSER 11 52 13.D1 DEMOLISH - PROJECTION SCREEN 23 82 29.D1 DEMOLISH - RADIATOR 26 05 05.D1 DEMOLISH - UTILITY POLE - COORDINATE WITH ELECTRICAL ©2017 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460 27 24 23.D1 DEMOLISH - WALL -MOUNTED SPEAKER 27 53 13.D1 DEMOLISH - WALL -MOUNTED CLASSROOM CLOCK 28 31 63.D1 DEMOLISH - FIRE ALARM HORN AND-S`TRQBEljGHT 06 41 13.D1 27 24 23.D1 Ep ARC��rF --------------= - - - - - - -T-- - - - - - -� � _- - - - - - - - - T__ 1 ' AR- 84084 4LP 4 j 02 41 OO.A6 I rq F �pt►'r I ! OD= o I DOCUMENT STATUS STATUS DATE 82 29.D1 02 41 OO.C45 23 ' - _ �____.. !- _ I PRELIMINARY 05/08/17 C3 ELI E3 I � REVISED PRELIMINARY 05/10/17 REVISED PRELIMINARY 05/12/17 REVISED PRELIMINARY 5/23/17 - - - - - - - - - - - - - - - - - - _ - - _�_ REVISED PRELIMINARY 6/12/17 BID DOCUMENTS 6/26/17 REVISION SCHEDULE 3 NORTH DEMOLITION ELEVATION NO. DESCRIPTION DATE 27 53 13.D1 11 52 13.D1 28 31 63.D1 28 31 63.D1 DRAWN BY: JEDD A. WALKER CHECKED BY: JEDD A. WALKER 27 24 23.D1 26 05 05.D1 10 28 OO.D1 PROJECT NAME: --- - -- - -- ----� -- SNO 233 TEACHING STUDIOS --------------- 1I PROJECT N0. 11285 o I I °I) fl ° ° SHEET NAME: 024100.A9 ;I I� II I` INTERIOR DEMOLITION ® I I �_ �, ❑ o ELEVATIONS j I II � I II 02 41 OO.C45 SOUTH DEMOLITION ELEVATION SHEET NUMBER: AD401 5 of 23 c u 07 92 OO.A6 10 14 OO.C2 10 14 OO.C3 CONSTRUCTION FLOOR PLAN 1/411 = 1'-011 KEYNOTE LEGEND 01 41 16.A1 ADA REQUIRED 4'-0" X 5'-0" CLEAR FLOOR SPACE AT DOOR 06 41 16.A1 PLASTIC LAMINATE—CLAD ARCHITECTURAL ADJUSTABLE ,,HELVES, 5TANIDARD.D BRA TS ,07�2 OO.A CAUL"D SEAVABANDOLOORETRA ON 07 92 OO.A6 CAULK AND SEAL ALL EXISTING AND NEW WALL ^ ^^ PENETRATIONS OCATED ROVE THE PEILING 10 14 OO.C2 MODIFY FACE PLATE OF EXISTING ROOM NAME / NUMBER PLAQUE TO ACCOMMODATE NEW NAMING AND NUMBERING ©2017 BYU-IDAHO 10 14 OO.C3 NEW ROOM NUMBER PLAQUE AND NEW 6X6 PLAQUE 525 SOUTH CENTER STREET REXBURG, IDAHO 83460 07 92 OO.A6 10 14 OO.C2 DOCUMENT STATUS STATUS DATE PRELIMINARY 05/08/17 REVISED PRELIMINARY 05/10/17 REVISED PRELIMINARY 05/12/17 REVISED PRELIMINARY 5/23/17 REVISED PRELIMINARY 6/12/17 NBID DOCUMENTS 6/26/17 REVISION SCHEDULE NO. DESCRIPTION DATE 1 ADDRESS COMMENTS 6/19/17 DRAWN BY: JEDD A. WALKER CHECKED BY: JEDD A. WALKER GENERAL NOTES PROJECT NAME: SNO 233 TEACHING 1. ALL EXISTING CONSTRUCTION IS STUDIOS TO REMAIN UNLESS SPECIFICALLY NOTED OTHERWISE. ALL EXISTING TO REMAIN ITEMS THAT ARE DAMAGED BY DEMOLITION AND/OR CONSTRUCTION ACTIVITIES SHALL BE REPAIRED OR REPLACED TO THE PROJECT N0. 11285 OWNER'S SATISFACTION. SHEET NAME: 2. FIELD VERIFY ALL EXISTING CONSTRUCTION CONDITIONS INCLUDING BUT NOT FLOOR PLAN LIMITED TO DIMENSIONS AND QUANTITIES. 3. REMOVE AND STORE ALL WIRELESS ACCESS POINTS FOR THE DURATION OF ALL CONSTRUCTION ACTIVITIES. SHEET NUMBER: MAINTAIN CABLE IN PLACE. REINSTALL WIRELESS ACCESS AE101 POINTS UPON COMPLETION OF THE PROJECT. 6 of 23 KEYNOTE LEGEND 09 51 OO.A13 SUSPENDED ACOUSTICAL TILE CEILING SYSTEM - SEE SCHEDULE AND DETAILS 21 13 13.A2 FULLY RECESSED PENDENT TYPE FIRE SPRINKLER HEAD 23 37 13.A3 RETURN AIR GRILLE WITH SOUND BOOT 23 37 13.N1 NEW LOCATION - SALVAGED SUPPLY AIR DIFFUSER 25 35.A1 UAL TEC OLOGY CUPAN SENSO 1 00. TX -IN L XTUR 27 21 33.N1 NEW LOCATIO - SALVAG D WIREL SS ACCE S POINT 8 31 /H TEC CONSTRUCTION REFLECTED CEILING 1 PLAN 1/411 = 1 '-0" GENERAL NOTES 1. ALL EXISTING CONSTRUCTION IS TO REMAIN UNLESS SPECIFICALLY NOTED OTHERWISE. ALL EXISTING TO REMAIN ITEMS THAT ARE DAMAGED BY DEMOLITION AND/OR CONSTRUCTION ACTIVITIES SHALL BE REPAIRED OR REPLACED TO THE OWNER'S SATISFACTION. 2. FIELD VERIFY ALL EXISTING CONDITIONS INCLUDING BUT NOT LIMITED TO DIMENSIONS AND QUANTITIES. 3. REMOVE AND STORE ALL WIRELESS ACCESS POINTS FOR THE DURATION OF ALL CONSTRUCTION ACTIVITIES. MAINTAIN CABLE IN PLACE. REINSTALL WIRELESS ACCESS POINTS UPON COMPLETION OF THE cD PROJECT. 0 ID ©2017 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460 x DOCUMENT STATUS STATUS DATE PRELIMINARY 05/08/17 REVISED PRELIMINARY 05/10/17 REVISED PRELIMINARY 05/12/17 REVISED PRELIMINARY 5/23/17 REVISED PRELIMINARY 6/12/17 BID DOCUMENTS 6/26/17 REVISION SCHEDULE N0. DESCRIPTION DATE 1 ADDRESS COMMENTS 6/19/17 DRAWN BY: JEDD A. WALKER CHECKED BY: JEDD A. WALKER PROJECT NAME: SNO 233 TEACHING STUDIOS PROJECT NO. 11285 SHEET NAME: CONSTRUCTION REFLECTED CEILING PLAN SHEET NUMBER: AE102 7 OF 23 n a r c CC KEYNOTE LEGEND 10 14 OO.C1 ROOM NAME / NUMBER PLAQUE 10 14 OO.C2 MODIFY FACE PLATE OF EXISTING ROOM NAME / NUMBER PLAQUE TO ACCOMMODATE NEW NAMING AND NUMBERING NOTE: ALL ELECTRICAL PANELS, COMMUNICATION CABLES AND TERMINATIONS, COMMUNICATION EQUIPMENT, HVAC EQUIPMENT, CONTROLS, ETC. SHALL BE RENUMBERED TO MATCH THE BELOW -REFERENCED ROOM NUMBERS. 10 14 OO.C2 ROOM RENUMBERING FLOOR PLAN 3/16" = 1'-0" 10 14 OO.C1 10 14 OO.C2 OLD #235 10 14 OO.C2 OFFICE 237 ©2017 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460 WALKER DOCUMENT STATUS STATUS DATE N PRELIMINARY 05/08/17 REVISED PRELIMINARY 05/10/17 REVISED PRELIMINARY 05/12/17 REVISED PRELIMINARY 5/23/17 REVISED PRELIMINARY 6/12/17 BID DOCUMENTS 6/26/17 REVISION SCHEDULE NO, DESCRIPTION DATE i i DRAWN BY: JEDD A. WALKER I OLD #237 OLD #238 CHECKED BY: JEDD A. WALKER 1 PROJECT NAME: I SNO 233 TEACHING STUDIOS OFFICE OFFICE 238 239 j PROJECT NO. 11285 1 SHEET NAME: !! ROOM RENUMBERING FLOOR PLAN 10 14 OO.C2 10 14 OO.C2 SHEET NUMBER: AE103 8 of 23 PT -1 234 WEST ELEVATION CTB -1 Al PT -1 i CTB -1 233 NORTH ELEVATION 4 1/411 = 1'-0" 06 41 16.A1 PT -1 CTB -1 234 NORTH ELEVATION PT -1 234 SOUTH ELEVATION 6 1 /4" = 1'-0" PT -1 PT -1 CTB -1 233 WEST ELEVATION 3 1/411 = 1 '-0" 06 41 16.A1 ij 11 I ; i A2 M 1 i j ! D233 KEYNOTE LEGEND 06 41 16.A1 PLASTIC LAMINATE -CLAD ARCHITECTURAL ADJUSTABLE SHELVES, STANDARDS, AND BRACKETS 26 27 26.A10 MIRROR FACE PLATE PT -1 4'-0" 4'-0" 06 41 16.A1 C1 r iD O CTB -1 5 234 EAST ELEVATION PT -1 I 06 41 16.A1 ©2017 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460 AR DOCUMENT STATUS w1 j i, li i� �i ii --------- .i 06 41 16.A1 It li it Lo ---------- REVISED PRELIMINARY 05/10/17 REVISED PRELIMINARY 05/12/17 REVISED PRELIMINARY 5/23/17 i CTB -1 233 NORTH ELEVATION 4 1/411 = 1'-0" 06 41 16.A1 PT -1 CTB -1 234 NORTH ELEVATION PT -1 234 SOUTH ELEVATION 6 1 /4" = 1'-0" PT -1 PT -1 CTB -1 233 WEST ELEVATION 3 1/411 = 1 '-0" 06 41 16.A1 ij 11 I ; i A2 M 1 i j ! D233 KEYNOTE LEGEND 06 41 16.A1 PLASTIC LAMINATE -CLAD ARCHITECTURAL ADJUSTABLE SHELVES, STANDARDS, AND BRACKETS 26 27 26.A10 MIRROR FACE PLATE PT -1 4'-0" 4'-0" 06 41 16.A1 C1 r iD O CTB -1 5 234 EAST ELEVATION PT -1 I 06 41 16.A1 ©2017 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460 AR DOCUMENT STATUS STATUS DATE PRELIMINARY 05/08/17 REVISED PRELIMINARY 05/10/17 REVISED PRELIMINARY 05/12/17 REVISED PRELIMINARY 5/23/17 REVISED PRELIMINARY 6/12/17 BID DOCUMENTS 6/26/17 REVISION SCHEDULE NO. T DESCRIPTION DATE DRAWN BY: JEDD A. WALKER CHECKED BY: JEDD A. WALKER PROJECT NAME: SNO 233 TEACHING STUDIOS PROJECT NO. 11285 SHEET NAME: INTERIOR Ell CONSTRUCTOIN ELEVATIONS CTB -1 26 27 26.A10 CTB -1 233 SOUTH ELEVATION 233 EAST ELEVATION SHEET NUMBER: AE401 9 of 23 PT -1 CTB -1 n 236 NORTH ELEVATION 1 /411 = 11-011 PT -1 PT -1 CTB -1 236 WEST ELEVATION 7 1/4" = 1'-0" 4' -0" 4'-0" 06 41 16.A1 C1 io 0 PT - KEYNOTE LEGEND 06 41 16.A1 PLASTIC LAMINATE -CLAD ARCHITECTURAL ADJUSTABLE SHELVES, STANDARDS, AND BRACKETS PT -1 CTB -1 G I B-1 236 SOUTH ELEVATION 236 EAST ELEVATION 6 1/411 = 1'-0" 51 /4" = 1'-0" PT -1 CTB -1 CTB -1 CTB -1 i 235 NORTH ELEVATION 235 WEST ELEVATION 235 SOUTH ELEVATION 1'-0"3 1 /4" = 1'-0" 1/41' = 1'-0" i i i PT -1 ©2017 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460 AR DOCUMENT STATUS STATUS DATE �i W2 REVISED PRELIMINARY 05/10/17 REVISED PRELIMINARY 05/12/17 REVISED PRELIMINARY 5/23/17 REVISED PRELIMINARY 6/12/17 BID DOCUMENTS 6/26/17 PT -1 CTB -1 236 WEST ELEVATION 7 1/4" = 1'-0" 4' -0" 4'-0" 06 41 16.A1 C1 io 0 PT - KEYNOTE LEGEND 06 41 16.A1 PLASTIC LAMINATE -CLAD ARCHITECTURAL ADJUSTABLE SHELVES, STANDARDS, AND BRACKETS PT -1 CTB -1 G I B-1 236 SOUTH ELEVATION 236 EAST ELEVATION 6 1/411 = 1'-0" 51 /4" = 1'-0" PT -1 CTB -1 CTB -1 CTB -1 i 235 NORTH ELEVATION 235 WEST ELEVATION 235 SOUTH ELEVATION 1'-0"3 1 /4" = 1'-0" 1/41' = 1'-0" i i i PT -1 ©2017 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460 AR DOCUMENT STATUS STATUS DATE PRELIMINARY 05/08/17 REVISED PRELIMINARY 05/10/17 REVISED PRELIMINARY 05/12/17 REVISED PRELIMINARY 5/23/17 REVISED PRELIMINARY 6/12/17 BID DOCUMENTS 6/26/17 REVISION SCHEDULE NO. DESCRIPTION DATE DRAWN BY: JEDD A. WALKER CHECKED BY: JEDD A. WALKER PROJECT NAME: SNO 233 TEACHING STUDIOS PROJECT NO. 11285 SHEET NAME: INTERIOR CONSTRUCTION ELEVATIONS SHEET NUMBER: 235 EAST ELEVATION AE402 10 OF 23 WALL TYk W GYPSUM BOARD SHALL BE CONTINUOUS BEHIND WALL TYPE'B' ULED 3. Q EXISTING ROOFING SYSTEM. CAULK OVER BACKER ROD. BOTH SIDES OF WALL. SCRIBE TOP OF ALL GYPSUM BOARD LAYERS TO METAL DECKING. SEE DETAIL 3/AE401 FOR CONDITION WHERE DECKING IS PERPENDICULAR TO WALL. EXISTING METAL DECKING WALL CONNECTION 4 EXISTING ROOFING SYSTEM. CAULK OVER BACKER ROD. BOTH SIDES OF WALL. SCRIBE TOP OF ALL GYPSUM BOARD LAYERS TO SIM METAL DECKING. SEE 1 DETAIL 3/AE401 FOR 501 CONDITION WHERE DECKING IS PERPENDICULAR TO WALL. EXISTING METAL DECKING GYPSUM BOARD: TOP OF WALL PERPENDICULAR TO 3 DECKING 311 1-011 9►Y111y1 2 WALL TYPE 'B' 3" = 1'-0" ULED qG ' ETE 1 WALL TYPE 'A' 3" = 1'-0" 20 GAUGE 3-5/8" METAL FRAMING AT 16" ON CENTER. TWO LAYERS 5/8" GYPSUM BOARD. ALL VERTICAL AND HORIZONTAL JOINTS SHALL BE STAGGERED. JOINTS OF FIRST LAYER SHALL BE TAPED AND MUDDED. ATTACH WITH 1" LONG NO. 6 DRYWALL SCREWS AT 8" ON CENTER AT THE PERIMETER AND 12" ON CENTER IN THE FIELD. ACOUSTICAL BATT INSULATION. SCHEDULED BASE. CAULK OVER BACKER ROD. BOTH SIDES OF WALL. EXISTING CONCRETE FLOOR. DOCUMENT STATUS STATUS DATE PRELIMINARY 05/08/17 REVISED PRELIMINARY 05/10/17 REVISED PRELIMINARY 05/12/17 REVISED PRELIMINARY 5/23/17 REVISED PRELIMINARY 6/12/17 BID DOCUMENTS 6/26/17 NOMINAL 3-11/16" WIDE BY 525 SOUTH CENTEDRSTREET 20 GAUGE SIM 3" DEEP MIN. NO. 20 GA. REXBURG, IDAHO 83460 3-5/8" METAL 3 STEEL U -SHAPED FRAMING AT AE501 DEFLECTION CHANNEL A 16" ON CENTER FASTENED TO METAL DECKING WITH METAL p ARS FASTENERS AT 12" O.C. l MAX. DO NOT FASTEN TO TOP TRACK OF WALL. DO NOT FASTEN TOP TRACK OF WALL TO 2 DEFLECTION CHA NEL. AR-�840�4 WALL CONNECTION 4 EXISTING ROOFING SYSTEM. CAULK OVER BACKER ROD. BOTH SIDES OF WALL. SCRIBE TOP OF ALL GYPSUM BOARD LAYERS TO SIM METAL DECKING. SEE 1 DETAIL 3/AE401 FOR 501 CONDITION WHERE DECKING IS PERPENDICULAR TO WALL. EXISTING METAL DECKING GYPSUM BOARD: TOP OF WALL PERPENDICULAR TO 3 DECKING 311 1-011 9►Y111y1 2 WALL TYPE 'B' 3" = 1'-0" ULED qG ' ETE 1 WALL TYPE 'A' 3" = 1'-0" 20 GAUGE 3-5/8" METAL FRAMING AT 16" ON CENTER. TWO LAYERS 5/8" GYPSUM BOARD. ALL VERTICAL AND HORIZONTAL JOINTS SHALL BE STAGGERED. JOINTS OF FIRST LAYER SHALL BE TAPED AND MUDDED. ATTACH WITH 1" LONG NO. 6 DRYWALL SCREWS AT 8" ON CENTER AT THE PERIMETER AND 12" ON CENTER IN THE FIELD. ACOUSTICAL BATT INSULATION. SCHEDULED BASE. CAULK OVER BACKER ROD. BOTH SIDES OF WALL. EXISTING CONCRETE FLOOR. DOCUMENT STATUS STATUS DATE PRELIMINARY 05/08/17 REVISED PRELIMINARY 05/10/17 REVISED PRELIMINARY 05/12/17 REVISED PRELIMINARY 5/23/17 REVISED PRELIMINARY 6/12/17 BID DOCUMENTS 6/26/17 REVISION SCHEDULE I DATE DRAWN BY: JEDD A. WALKER CHECKED BY: JEDD A. WALKER PROJECT NAME: SNO 233 TEACHING STUDIOS PROJECT NO. 11285 SHEET NAME: CONSTRUCTION DETAILS SHEET NUMBER: AE501 11 OF 0 k] FIRST LINE OF BRACING 4'-0" OR LESS FROM WALL BOUNDARY. CEILING SUSPENSION SYSTEM. 12 GA. SPLAY WIRE AT 12'-0" O.C. IN EACH PLAN 1/2" CONDUIT OF EACH RUNNER. COMPRESSION BRACE. FULL HEIGHT. TYPICAL. o� 12 GA. VERTICAL WIRES AT 4'-0" O.C. 2" MIN. SUSPENDED CEILING BRACING DEAIL 3/4" = 1'-0" A .c -o n NOTE: r P�. CEILINGS ARE REQUIRED CIQ�G TO BE BRACED UNLESS ALL 1`L OF THE FOLLOWING CRITERIA ARE MET: (1) ROOM AREA IS SMALLER THAN 144 SQ. FT., AND (2) THERE ARE WALLS ON FOUR SIDES, AND (3) THE WALLS EXTEND TO THE STRUCTURE. SUSPENDED CEILING DETAIL 3/4" = 1'-0" BLOCKING DETAIL 1 1 1 /2" = 1'-0" WALL CONSTRUCTION. SEE WALL TYPES. 20 GA. X 6" FLAT STEEL BLOCKING. GYPSUM BOARD. ACCESSORY MOUNTED OVER FINISHED WAL. TYPICAL BLOCKING RED BEHIND WALL TED ACCESSORIES QUIPTMENT. ©2017 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460 DOCUMENT STATUS STATUS DATE PRELIMINARY 05/08/17 REVISED PRELIMINARY 05/10/17 REVISED PRELIMINARY 05/12/17 REVISED PRELIMINARY 5/23/17 REVISED PRELIMINARY 6/12/17 BID DOCUMENTS 6/26/17 REVISION SCHEDULE NO. DESCRIPTION DATE DRAWN BY: JEDD A. WALKER CHECKED BY: JEDD A. WALKER PROJECT NAME: SNO 233 TEACHING STUDIOS PROJECT NO. 11285 SHEET NAME: CONSTRUCTION DETAILS SHEET NUMBER: AE502 12 of 23 DOOR SCHEDULE DOOR GLAZING DOOR FRAME FIRE COMMENTS TAG TYPE ROOM # SINGLE / PAIR WIDTH HEIGHT DOOR MATERIAL TYPE MATERIAL RATING BYU D233 D2 233 SINGLE 3'- 0" 7'- 0" EXISTING EXISTING - REPAIR & REFINISH F1 EXISTING - PAINT 20 MIN H1, H2, H3, H4, H5, REPAIR AND REFINISH DOOR D234 D2 234 SINGLE 3'- 0" 7'-0" EXISTING EXISTING - REPAIR & REFINISH F1 EXISTING - PAINT 20 MIN H1, H2, H3, H4, H5, REPAIR AND REFINISH DOOR D235 D1 235 SINGLE 3' - 0" 7'-0" 1/4" FIREGLASS 20 EXISTING - REPAIR & REFINISH F1 EXISTING - PAINT 20 MIN H1, H2, H3, H4, H5, REPAIR AND REFINISH DOOR D236 D1 236 SINGLE 3'- 0" 7' - 0" 1/4" FIREGLASS 20 EXISTING - REPAIR & REFINISH F1 EXISTING - PAINT 20 MIN H1, H2, H3, H4, H5, REPAIR AND REFINISH DOOR D237 D3 237 SINGLE 3'- 0" 7'- 0" NONE EXISTING F1 EXISTING 20 MIN EXISTING D238 D3 238 SINGLE 3'- 0" 7'-0" NONE EXISTING F1 EXISTING 20 MIN EXISTING D239 D3 239 SINGLE 3' - 0" 7'-0" NONE EXISTING F1 EXISTING 20 MIN EXISTING 3' - 4" T- 4" 3' - 4" ©2017 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460 T- 0" 3'- 0" T- 0" HARDWARE NOTES: FINISH SHALL BE US26D, UNLESS OTHERWISE NOTED. H1 HINGING: EXISTING TO REMAIN USING AN EXISTING H2 LOCKSET: REMOVE EXISTING LOCKSET OR BLANK APPROVED AND ' DOOR LITE. , PLATE. PROVIDE NEW SCHLAGE ND SERIES WITH ARcyr o �66„ LISTED UL SHOP, CUT A NEW FIRE- RHODES LEVER. FUNCTION: SCHLAGE ND50PD (ANSI F82). �SFv i ' H3 DOOR BOTTOM: PEMKO 430—RL AUTOMATIC DOOR 01 RATED WINDOW BOTTOM N U `t o / d o H4 WALL STOPS: IVE WS406/407-CCV. L o EXISOTING FIRE -THE H5 GASKETS: NGP 700SA AR- 84 4 RATED DOOR. ` GLAZING TO BE ` �► O 00 1 1/4" THICK FIRE - n, RATED FIREGLASS 20 ` NN BY TGP. NN NS � N DOCUMENT STATUS EXISTING SOLID CORE WOOD EXISTING SOLID CORE WOOD EXISTING SOLID CORE EXISTING WELDED HOLLOW STATUS DATE PRELIMINARY 05/08/17 DOOR WITH NEW WINDOW DOOR WITH EXISTING WINDOW WOOD DOOR METAL DOOR FRAME REVISED PRELIMINARY 05/10/17 Dl D2 D3 Fl REVISED PRELIMINARY 05/12/17 REVISED PRELIMINARY 5/23/17 - REVISED PRELIMINARY 6/12/17 BID DOCUMENTS 6/26/17 ROOM FINISH SCHEDULE REVISION SCHEDULE FINISHES NO. DESCRIPTION DATE 1 ADDRESS COMMENTS 6/19/17 NUMBER NAME AREA PERIMETER BASE FLOOR WALL CEILING COMMENTS/NOTES 233 OFFICE 138 SF 50'- 4 1/8" CTB -1 CPT -1 PT -1 ACT -1 234 OFFICE 167 SF 56'- 11 11/16" CTB -1 CPT -1 PT -1 ACT -1 235 OFFICE 135 SF 48'- 1 1/4" CTB -1 CPT -1 PT -1 ACT -1 DRAWN BY: JEDDA. WALKER 236 OFFICE 134 SF 47'- 11 5/8" CTB -1 CPT -1 PT -1 ACT -1 CHECKEDBY: JEDDA.WALKER PROJECT NAME: 237 OFFICE 138 SF 49'- 8 1/2" 238 OFFICE 137 SF 49'- 7 3/4" SNO 233 TEACHING 239 OFFICE 137 SF 49'- 7 3/4" STUDIOS FLOOR FINISHES WALL BASE FINISHES MARK DESCRIPTION MANUFACTURER PRODUCT MODEL # MARK DESCRIPTION MANUFACTURER PRODUCT MODEL # PROJECT NO. 11285 SHEET NAME: CPT -1 CARPET INTERFACE PRODUCT: ENTROPY 1464802500 CTB -1 CARPET BASE INTERFACE PRODUCT: ENTROPY 1464802500 COLOR: 9606 PRALINE COLOR: 9606 PRALINE DOOR, ROOM, FLOOR, BASE, WALL, & CEILING SCHEDULES ALL SHE CEILING FINISHES MARK DESCRIPTION MANUFACTURER PRODUCT MODEL # TEM DESCRIPTION MANUFACTURER PRODUCT MODEL # PT -1 PAINT SHERWIN WILLIAMS HIGHLY REFLECTIVE CASHMERE CT -1 ACOUSTICAL UNITED STATES 2'x 2'x 3/4" ACT USG MARS SHEET NUMBER: SASHMERE. MEDIUM TILE GYPSUM COMPANY Mars ClimaPlus (86985) CLIMAPLUS LUSTER. MATCH FLEdge Donn Fineline AE601 SHELL WHITE BY 1/8 1/8 DXFF Grid COL MBIA. 13 OF 23 FIXTURE AND EQUIPMENT SCHEDULE MARK DESCRIPTION MANUFACTURER PRODUCT MODEL# COUNT Al BARREL DIFFUSER LAMVIN INC. 24 -INCHES WIDE X 48 -INCHES TALL. FABRIC: GUILFORD OF MAINE, STYLE: 2335 ANCHORAGE, COLOR: 2093 FOSSIL. TYPE I BARREL DIFFUSER 8 A2 ACOUSTICAL WALL PANEL LAMVIN INC. 48 -INCHES WIDE X 48 -INCHES TALL X 2 -INCHES THICK, 6-7 LB DENSITY. FABRIC: GUILFORD OF MAINE, SONIC STANDARD PANEL 8 STYLE: 2335 ANCHORAGE, COLOR: 2093 FOSSIL. Cl COAT HOOKS BYU-IDAHO CARPENTRY SERVICES CAMPUS STANDARD COAT HOOK STRIP 4 M1 MIRROR YOU DECIDE 4'-0" X 4'-0", TEMPERED 4 W1 WINDOW TREATMENT - SHADE MECHO SYSTEMS 6'-2" WIDE X 7'-2" TALL (FIELD VERIFY), PROVIDE WITH SNAPLOC FASCIA AND END CAPS MECHO/5 SYSTEM 1 W2 WINDOW TREATMENT - SHADE MECHO SYSTEMS 2'-0" WIDE X 7'-2" TALL (FIELD VERIFY), PROVIDE WITH SNAPLOC FASCIA AND END CAPS MECHO/5 SYSTEM 2 ©2017 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460 AR�y�I LK. AR- 84084 . Zk DOCUMENT STATUS STATUS DATE PRELIMINARY 05/08/17 REVISED PRELIMINARY 05/10/17 REVISED PRELIMINARY 05/12/17 REVISED PRELIMINARY 5/23/17 REVISED PRELIMINARY 6/12/17 BID DOCUMENTS 6/26/17 REVISION SCHEDULE NO. DESCRIPTION DATE DRAWN BY: JEDD A WALKER CHECKED BY: JEDD A. WALKER PROJECT NAME: SNO 233 TEACHING STUDIOS PROJECT NO. 11285 SHEET NAME: FIXTURE AND EQUIPMENT SCHEDULE Y SHEET NUMBER: ri 2. D AE602 V DD 14 OF 23 II 1 FURNITUF (N (J 19 PLAN 233 & 234 Cl N J ©2017 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460 OF DOCUMENT STATUS STATUS DATE PRELIMINARY 05/08/17 REVISED PRELIMINARY 05/10/17 REVISED PRELIMINARY 05/12/17 REVISED PRELIMINARY 5/23/17 REVISED PRELIMINARY 6/12/17 BID DOCUMENTS 6/26/17 REVISION SCHEDULE NO. DESCRIPTION DATE DRAWN BY: JEDD A. WALKER CHECKED BY: JEDD A. WALKER PROJECT NAME: SNO 233 TEACHING STUDIOS PROJECT NO. 11285 SHEET NAME: ARCHITECTURAL INTERIORS FURNITURE PLAN - 233 & 234 SHEET NUMBER: A1101 15 OF 23 FURNITURE PLAN 235 & 236 1/2" = 1'-0" ©2017 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460 DOCUMENT STATUS STATUS DATE PRELIMINARY 05/08/17 REVISED PRELIMINARY 05/10/17 REVISED PRELIMINARY 05/12/17 REVISED PRELIMINARY 5/23/17 REVISED PRELIMINARY 6/12/17 BID DOCUMENTS 6/26/17 REVISION SCHEDULE I DRAWN BY: JEDD A. WALKER CHECKED BY: JEDD A. WALKER PROJECT NAME: SNO 233 TEACHING STUDIOS PROJECT NO. 11285 SHEET NAME: ARCHITECTURAL INTERIORS FURNITURE PLAN - 235 & 236 SHEET NUMBER: A1102 16 OF 23 P OFFICE O 234 L H p R J F O i O NORTH FURNITURE ELEVATION - 234 EAST FURNITURE ELEVATION - 234 1/2" = 1'-0" 2 WEST FURNITURE ELEVATION - 233 I � !� II i i i �! I OFFICE 0 233 I ii L J 0 NORTH FURNITURE ELEVATION - 233 11 /2" = 1'-0" ©2017 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460 AR- 840$4 s�q FOF110'i DOCUMENT STATUS STATUS DATE PRELIMINARY 05/08/17 REVISED PRELIMINARY 05/10/17 REVISED PRELIMINARY 05/12/17 REVISED PRELIMINARY 5/23/17 REVISED PRELIMINARY 6/12/17 BID DOCUMENTS 6/26/17 REVISION SCHEDULE NO. DESCRIPTION DATE DRAWN BY: JEDD A. WALKER CHECKED BY: JEDD A. WALKER PROJECT NAME: SNO 233 TEACHING STUDIOS PROJECT NO. 11285 SHEET NAME: ARCHITECTURAL INTERIORS ELEVATIONS - 233 & 234 SHEET NUMBER: A1401 NORTH FURNITURE ELEVATION - 236 4 1 /2" = 1'-0" EAST FURNITURE ELEVATION - 236 1/2" = 1'-0" u OL L K OF O sOE D P OFFICE 235 G O � O WEST FURNITURE ELEVATION - 235 1/2" = 1'-0" -�. O OFFICE 235 D B O 1 NORTH FURNITURE ELEVATION - 235 1 /2" = 1'-0" ©2017 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460 AR DOCUMENT STATUS STATUS DATE PRELIMINARY 05/08/17 REVISED PRELIMINARY 05/10/17 REVISED PRELIMINARY 05/12/17 REVISED PRELIMINARY 5/23/17 REVISED PRELIMINARY 6/12/17 BID DOCUMENTS 6/26/17 REVISION SCHEDULE NO. DESCRIPTION DATE DRAWN BY: JEDD A. WALKER CHECKED BY: JEDD A. WALKER PROJECT NAME: SNO 233 TEACHING STUDIOS PROJECT NO. 11285 SHEET NAME: ARCHITECTURAL INTERIORS ELEVATIONS - 235 & 236 SHEET NUMBER: A1402 TAG MANUFACTURER STYLE NUMBER FURNITURE SCHEDULE DESCRIPTION c� z W w W z ROOM # • A Steelcase 4821410 Steelcase - Seating - Amia 482 Series - Chair: Upholstery/Arm/Caster 4 233, 234, 235, 236 B Steelcase UEP24 Steelcase - Answer Solution - End Panel - On Module: 24" - Right 2 233,235 C Steelcase RLF18362F Steelcase - Universal Storage - Lateral File - 2 High - Flush Steel: 18" D x 36" W 4 233, 234, 235, 236 D Steelcase US2430 Steelcase - Universal Systems Worksurface - Straight - 0.5" Cord Drop - 3mm Edge: 23 1/2" x 30" 4 233, 234, 235, 236 E Steelcase UEC2222R Steelcase - Universal Systems Worksurface - Extended Corner - Curved Front - 0.5 Cord Drop: Right - 24" x 24" x 42" x 72" - Cable Scallop 2 233,235 F Steelcase US2436 Steelcase - Universal Systems Worksurface - Straight - 0.5" Cord Drop - 3mm Edge: 23 1/2" x 36" 4 233, 234, 235, 236 ©2017 BYU-IDAHO G Steelcase RPF2427AF Steelcase - Universal Storage - Fixed Pedestal - Flush Steel: 2 Box/1 File - 27" H x 22 5/8" D 4 233, 234, 235, 236 525SOUTH C LATERAHO S E T H Steelcase UEP24 Steelcase - Answer Solution - End Panel - On Module: 24" - Left 2 234,236 J Steelcase TS71836TB Steelcase - Answer Solution - Tackboards for Use with Wall Channels: 36" W 4 233, 234, 235, 236 K Steelcase RBB36TAK Steelcase - Universal Storage - Bin In the Case - Flat Front: For Answer and Kick - 36" W 4 233, 234, 235, 236 L Steelcase LT2 Steelcase - Answer Solution - Lighting - Underline- Light - Task: T2, 22W, Basic 0835 Black 8 233, 234, 235, 236 SEp AR�h� M Steelcase RBB42TAK Steelcase - Universal Storage - Bin In the Case - Flat Front: For Answer and Kick - 42" W 2 233, 234, 235, 236 Vt4� 1 N Steelcase TS71842TB Steelcase - Answer Solution - Tackboards for Use with Wall Channels: 42" W 4 233, 234, 235, 236 P Steelcase TS7BSWHC Steelcase - Answer Solution - Wall Channel - 66H: 36" W 4 233, 234, 235, 236 A 5 Q Steelcase TS7BSWHC Steelcase - Answer Solution - Wall Channel - 66H: 42" W 4 233, 234, 235, 236 AR- 8408 R Steelcase UEC2222L Steelcase - Universal Systems Worksurface - Extended Corner - Curved Front - 0.5 Cord Drop: Left - 24" x 24" x 72" x 42" - Cable Scallop 2 234,236 S Steelcase UCANT Steelcase - Answer Solution - Panel Mounted Universal Support - Cantilever: Left 4 233, 234, 235, 236 T STEELCASE ASHC1921X1: V-9" x 1 -7 4 233, 234, 235, 236 F F rads U Steelcase RSH42TAK Steelcase - Answer Solution - Universal Shelf: 42" 2 V Steelcase 475482M Steelcase - Seating - Player 475 Series - Sled Base Multi Use Chair: Smooth Plastic Arm 8 X Yamaha Upright Piano: Yamaha P-22 SW 4 4 1233,234,235,236 DOCUMENT STATUS i J J STATUS DATE PRELIMINARY 05/08/17 REVISED PRELIMINARY 05/10/17 REVISED PRELIMINARY 05/12/17 REVISED PRELIMINARY 5/23/17 REVISED PRELIMINARY 6/12/17 BID DOCUMENTS 6/26/17 REVISION SCHEDULE NO. DESCRIPTION DATE DRAWN BY: JEDD A. WALKER CHECKED BY: JEDD A. WALKER PROJECT NAME: SNO 233 TEACHING STUDIOS PROJECT NO. 11285 SHEET NAME: ARCHITECTURAL INTERIORS FURNITURE SCHEDULE SHEET NUMBER: A1601 19 OF 23 OFFICE 233 PERSPECTIVE OFFICE 233 AXONOMETRIC 02017 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460 A-1yi AR DOCUMENT STATUS STATUS DATE PRELIMINARY 05/08/17 REVISED PRELIMINARY 05/10/17 REVISED PRELIMINARY 05/12/17 REVISED PRELIMINARY 5/23/17 REVISED PRELIMINARY 6/12/17 BID DOCUMENTS 6/26/17 REVISION SCHEDULE I DATE DRAWN BY: JEDD A. WALKER CHECKED BY: JEDD A. WALKER PROJECT NAME: SNO 233 TEACHING STUDIOS PROJECT NO. 11285 SHEET NAME: ARCHITECTURAL INTERIORS 3D REPRESENTATIONS OFFICE 233 SHEET NUMBER: A1901 20 of 23 OFFICE 234 PERSPECTIVE OFFICE 234 AXONOMETRIC ©2017 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460 ;ctrit l'R STATUS DATE PRELIMINARY 05/08/17 REVISED PRELIMINARY 05/10/17 REVISED PRELIMINARY 05/12/17 REVISED PRELIMINARY6/12/17 BID DOCUMENTS r 6/26/17 REVISION SCHEDULE DRAWN BY: JEDD A. WALKER CHECKED BY: JEDD A. WALKER PROJECT NAME: SNO 233 TEACHING STUDIOS PROJECT NO. 11285 SHEET NAME: ARCHITECTURAL INTERIORS 3D REPRESENTATIONS OFFICE 234 SHEET NUMBER: A1902 21 of 23 OFFICE 235 PERSPECTIVE 01 - � OFFICE 235 AXONOMETRIC ©2017 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460 AR DOCUMENT STATUS STATUS DATE PRELIMINARY 05/08/17 REVISED PRELIMINARY 05/10/17 REVISED PRELIMINARY 05/12/17 REVISED PRELIMINARY 5/23/17 REVISED PRELIMINARY 6/12/17 BID DOCUMENTS 6/26/17 REVISION SCHEDULE I DATE DRAWN BY: JEDD A. WALKER CHECKED BY: JEDD A. WALKER PROJECT NAME: SNO 233 TEACHING STUDIOS PROJECT NO. 11285 SHEET NAME: ARCHITECTURAL INTERIORS 3D REPRESENTATIONS OFFICE 235 SHEET NUMBER: A1903 22 OF OFFICE 236PERSPECTIVE � OFFICE 236 AXONOMETRIC 02017 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460 AR DOCUMENT STATUS STATUS DATE PRELIMINARY 05/08/17 REVISED PRELIMINARY 05/10/17 REVISED PRELIMINARY 05/12/17 REVISED PRELIMINARY 5/23/17 REVISED PRELIMINARY 6/12/17 BID DOCUMENTS 6/26/17 REVISION SCHEDULE I DRAWN BY: JEDD A. WALKER CHECKED BY: JEDD A. WALKER PROJECT NAME: SNO 233 TEACHING STUDIOS PROJECT NO. 11285 SHEET NAME: ARCHITECTURAL INTERIORS 3D REPRESENTATIONS OFFICE 236 SHEET NUMBER: A1904 23 OF 23 I�iJI Iii JI I I I L --j' L --j' I 3 VN I J LI ----r{------------r�-----rt------------ ----� -- -----� {-----� I {----------, I rT-1 FF ' I' I II I i II I 31x12 GOLD DECK HOT DECK rrrr. i r. DEMOLITION PLAN 5GALE: I/8" = 1'-0" l;Nwm MECHANICAL CAL FLA ` 5GALE: 1/8" = 1'-0" NORTH PLAN NOTES: O REMOVE H16H PRE55URE BRANCH DUCTS AND GAP AT MAIN TRUNK DUCT. SEAL AIR TIGHT. FIELD VERIFY EXACT 5IZE AND LOCATION. O2 PROVIDE AND INSTALL NEW DUAL DUCT VAV BOX A5 SPECIFIED. GONNEGT TO EXI5TIN6 HIGH PRESSURE GOLD � HOT DECK DUGTWORK AND TO NEW OR EXI5TIN6 DIFFU5ER(5) A5 SHOWN. FIELD VERIFY EXACT 5IZE AND LOCATION OF EX15TIN6 DUGTWORK ABOVE GEILIN65 AND ADJUST ACTUAL BOX LOCATION AS REQUIRED TO MAINTAIN ACCESS AS RECOMMENDED BY MANUFACTURER. 3O EXI5TIN6 DIFFUSER TO BE RELOCATED. 015CONNEGT FROM EXI5TIN6 DUGTWORK AND RECONNECT TO NEW DUGTWORK A5 5HOWN. RE-BALANGE TO GFM A5 INDICATED. 4O DISCONNECT AND REMOVE ROOM SENSOR, EXI5TIN6 DIFFUSER 6RILLE, RETURN GRILLE OR VAV BOX. FIELD VERIFY EXACT 5IZE AND LOCATION. RETURN VAV BOX TO OWNER. ©2017 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460 5O PROVIDE AND INSTALL NEW ROOM SENSOR ON WALL AND CONNECT TO GORRE5PONDIN6 VAV BOX AND TO BUILDIN6 CONTROL SYSTEM. NEW SENSOR TO MATCH DOCUMENT STATUS TTATUS EXI5TIN6 BUILDING CONTROLS. CONTRACTOR TO FIELD VERIFY EXI5TIN6 CONTROLS PRIOR TO BIDDING. (. PROVIDE AND INSTALL RETURN AIR 6RILLE AND SOUND BOOT A5 5PEGIFIED GOORDIN/A TE ACTUAL REVISION SCHEDULE LOCATION WITH EXI5TIN6 DUGTWORK AND LIGHT NO. DESCRIPTION DATE FIXTURES. O RELOCATE EXI5TIN6 FIRE SPRINKLER PIPING & HEADS A5 REQUIRED BY NFPA-13 CODE REQUIREMENTS. ADD HEADS 1F NEEDED. DRAWN BY: TANNER DAVIS CHECKED BY: DWAYNE STUDWEEKS PROJECT SO 015GONNEGT AND REMOVE EXI5TIN6 FIN TUBE. GAP NAME SNO 233 TEACHING PIPING BELOW FLOOR STUDIOS O ALL DUCT PENETRATIONS THRU WALL TO BE SEALED AND AIRTIGHT. ORIGINAL DRAWING 516NED BY: DWAYNE G. 9)DWEEK5 DATE ORIGINAL 516NED: JUNE 23, 2011 PROJECT NO. 17043 ORIGINAL ON FILE AT ENGINEERED 5Y5TEM5 A550GIATE5 SHEET NAME: Engineered DEMOLITION / SS�oNAL Fac Systems MECHANICAL FLOOR �r,ISTfRFo�yAssociates PLAN 1355 EAST CENTER 5762 POCATELLO, IDAHO 83201 PHONE: (208) 233-0501 SHEET NUMBER: FAX: (208) 233-0529 C S�) EMAIL: esa@engsystems.com M 101 ESA JOB NUMBER: 17043 1 OF 3 LOW PRE55URE 5UPPLY AIR DUCT. 5EE PLAN FOR INDIVIDUAL 51ZE5- NEW DUAL DUCT VARIABLE AIR MIXING BOX WITH ELECTRONIC GONTROLLER5 HOT DECK FLEXIBLE DUCT. CONNECT TO MIXING BOX WITH "PANDUIT" 5TRAP5 AND SEAL AIR -TIGHT GOLD DECK FLEXIBLE DUCT. CONNECT TO MIXING BOX WITH "PANDUIT" 5TRAP5 AND SEAL AIR -TIGHT NO 5GALE FLEXIBLE CONNECTION VARIABLE AIR CONTROL DAMPER WITH ELECTRONIC CONTROL 5Y5TEM. 5EE 5PEGIFIGATION5 FOR CONTROL HOOK-UP AND OPERATION 01 NOTE: 5OUND BOOTS ARE REQUIRED ON ALL GEILIN6 RETURN AIR 6RILLE5 NOT DUCTED BACK TO UNITS DUCT BACK A5 CORRIDOR WALL. � LAY -IN RETURN AIR GRILLE — 2A UL FIRE RATED GEILIN6 RADIATION FIRE DAMPER SOUND SOOT DETAIL. NO 5GALE VOLUME SOX 50HEOULE 5YM. TYPE 51ZE (G.F.M) RANGE (G.F.M) AIR INLET AIR OUTLET GOLD DECK HOT DEGK CONTROL REMARK5 GFM MAX. GFM MIN. GFM MAX. GFM MIN. VBVB DUAL DUGT 200 0-300 6"(p 8"(p 200 50 200 50 DIGITAL GRILLE AND RE615TER 5GHEOULE 5YM. 51ZE THROW CFM GON5TR. EIN15H BRANCH DUCT E.D. O.B. REMARK5 FR__ 11 12 x 24 --- 400-qO0 STEEL WHITE --- NO NO TITU5 PERFORATED 6RILLE5 WITH SOUND BOOT DUCT WITH AGOU5TIGAL LINER. PAINT IN51DE FLAT BLACK. ORIGINAL DRAWING 516NED BY: DWAYNE G. 5UDWEEK5 DATE ORIGINAL 516NED: JUNE 23, 2011 ORIGINAL ON FILE AT ENGINEERED 5Y5TEM5 A550GIATE5 �S\ONAL F� SOI S T FR�.o��.��� 5762 s o c) OF \0�� \ C. S� Engineered Systems Associates 1355 EAST CENTER POCATELLO, IDAHO 83201 PHONE: (208) 233-0501 FAX: (208) 233-0529 EMAIL: esa@engsystems.com ESA JOB NUMBER: 17043 ©2017 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460 STATUS REVISION SCHEDULE NO. DESCRIPTION I DATE DRAWN BY: TANNER DAVIS CHECKED BY: DWAYNE STUDWEEKS NAME: SNO 233 TEACHING STUDIOS PROJECT NO. 17043 SHEET NAME: DEMOLITION / MECHANICAL FLOOR PLAN SHEET NUMBER: M201 15° 15° D D MIN. 2 PIECE 500 ELBOW 22-1/2° 22-I/2° 22-1/2° II -1/4° II -1/4° D D MIN. 5 PIEGE a00 ELBOW NP 17UCT 3 NO 5GALE 5 PIEGE 450 ELBOW 10° r°20° 22 10° D D MIN. 4 PIECE 600 ELBOW 20 6A. PERFORATED METAL 5OUND BAFFLE FLUSH WITH BRANCH DUCT MAIN DUCT - 1/2" HOLES ON II/I6" GENTER5. DIAMETER OF DIRECTION GIRGLE BENT TO FIT MAIN TRUNK DUCT - OF AIR FLOW DUGT = Ib BRANCH DUCT 450 Y TEE DIRECTION - - - I OF AIR FLOW BRANCH DUCT QO° CONICAL TEE DIRECTION TRUNK DUG T OF AIR FLOW 100 STRAIGHT TEE TRUNK DUGT — BRANCH DUCT DIRECTION OFIAIR FLOW q00 ELONGATED TEE NO 5GALE T F. DIRECTI OF AIR 2 -WAY 450 Y ANGH DUCT ORIGINAL DRAWIN6 516NED BY: DWAYNE G. 50DWEEK5 DATE ORIGINAL 516NED: JUNE 23, 2011 OR16INAL ON FILE AT ENGINEERED 5Y5TEM5 A55OGIATE5 Irl S T ER�'o%y��� 5"762 Engineered Systems Associates 1355 EAST CENTER POCATELLO, IDAHO 83201 PHONE: (208) 233-0501 FAX: (208) 233-0529 EMAIL: esa@engsystems.com ESA JOB NUMBER: 17043 ©2017 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460 I REVISION SCHEDULE NO. DESCRIPTION I DATE DRAWN BY: TANNER DAVIS CHECKED BY: DWAYNE STUDWEEKS NAME: SNO 233 TEACHING STUDIOS PROJECT NO. 17043 SHEET NAME: DEMOLITION / MECHANICAL FLOOR PLAN SHEET NUMBER: M202 ELECTRICAL SPECIFICATIONS 1. INTENT: 10. CONDUIT: Provide and install complete and operable electrical systems including but All conduit material and installation methods shall be as not not limited to; lighting, power, receptacles, data, fire alarm ande etc. allowed by the NEC, local AHJ and as directed by the Provide all required connections to all Mechanical and Plumbing owner. equipment, as indicated and required, including all conduits, wiring and Utilize GFCI and Tamper -proof devices in all locations as controls. Coordinate with mechanical contractor and drawings. defined by the NEC. 2. COMPLIANCE WITH CODES: 11. CONDUCTORS: All work and material shall comply with all applicable codes, safety Type THWN or THHN capper wire insulated for 60OV. orders, laws, ordinances and regulations of governing authorities and Smallest wire shall be #14 AWG unless noted otherwise. other agencies having jurisdiction including regulations of the State All wiring shall be Copper unless indicated otherwise. and Local Fire Marshall, unless detailed as specified to a more Type MC cable shall be permitted, provided it is installed in restrictive standard or higher requirement. concealed areas and installation complies with the Local All equipment shall be readily accessible for maintenance and AHJ and NEC requirements. 3. INTERPRETATION OF DRAWINGS: Type NM cable is only permitted in locations allowed by the The electrical drawings are essentially diagrammatic in that all provisions Local AHJ and NEC. necessary to conform to structural, architectural, mechanical and Use "Ideal Yellow" pulling compound for all wire pulls.Use plumbing systems can not be shown. All installations shall be adjusted Scotchlock connectors for all splices in #12 wire and tape as necessary to conform and to avoid obstructions, without additional bolted pressure connectors for larger wire. cost to the owner. All work, material and equipment called for by notes, Upon completion of the work, prior to final inspection, schedules or otherwise indicated on the drawings shall be furnished thoroughly clean all exposed fixtures, trim and and isntalled as though fully set forth in these specifications. 12. GROUNDING: Coordinate conduit installation with pipes, steel, footings and All conduit, branch circuits, feeders and etc. shall be 4. VISITING THE SITE: provided with a grounding conductor. All grounding Contractor shall visit the site and become acquainted with conditions to conductors shall be insulated and green in color, size as be encounterd. Extra funds will not be allowed due to failuer to shown. examine the site and to included existing conditions in bid price. Test all conductors for shorts, opens, grounds or other 5. COORDINATION WITH UTILITIES: 13.WIRING DEVICES: Devices shall be Standard type, Specification grade, 20A These plans have been prepared without utility company comments. rated. The contractor shall verify exact requirements for the electrical, Device color: Grey telephone and communication services with the utility company Decora style devices are prohibited. representatives and provide all work and pay all costs for a complete Utilize GFCI and Tamper -proof devices in all locations as and operating systems, as directed by the governing utilities. defined by the NEC. 6. MATERIALS AND WORKMANSHIP: Wiring devices shall be as installed as allowed by the All workmanship shall be performed by skilled electricians using NEC, local AHJ. the best standard practives of the trade. All materials shall, unless SIZE (SEE NOTES BELOW) otherwise noted, be new and in perfect condition and working 14. DEVICE PLATES: order. All material for similar uses shall be of the same type, Devices plates: Stainless Steel, as directed by owner material and manufacturer for ease of future maintaenance. and as required by the NEC. All equipment shall be readily accessible for maintenance and CABLES, X=CONDUIT SIZE (SEE NOTES BELOW) repairs. All materials, fixtures and equipment shall be covered or 15. LIGHTING FIXTURES: sealed upon installation so as to provide for safety and to insure As indicated in schedules. All light fixtures shall that operation and appearance will be maintained after tinstalled and connected by the Electrical Contractor. subsequent construction operations. 7. EXECUTION: 17.CLEAN-UP: Raceway installation: Seperate underground conduits in a Upon completion of the work, prior to final inspection, common trench 4" minimum horizontally, 12" minimum from thoroughly clean all exposed fixtures, trim and other utility lines. Minimum conduit depth shall be 18", equipment and leave the entire installation in a neat, Coordinate conduit installation with pipes, steel, footings and clean and usable condition. Remove all cement, paint, ducts installed by other trades. Install conduit runs exposed to grease, oil and other foreign substances. view parallel or at right angles to structural members, walls or TELEPHONE/DATA OUTLET; _= # OF building lines. Support conduit with one -hole malleable factory 18.TEST: made pipe straps, fastended with screws. Test all conductors for shorts, opens, grounds or other TI D -X defects. Correct any defective work and re -test. 8. OPERATING AND ADJUSTING: Demonstrate continuous satisfactory operation of all The owner reserves the right to operate any systems of electrical systems and equipment. equipment prior to final comletion and acceptance of the work. Provide training to the owner on electrical systems as Such perliminary operation shall not be construed as an needed for owner operation and maintenance of building. acceptance of any work. FIXTURE LOCATIONS, CEILING TYPES, ETC. Each piece of equipment and all of the systems shall be 19. GUARANTEE: adjusted to insure proper functioning and shall be left in first Prior to final acceptacne of the project, deliver to the class operating condition. owner a written one year guarantee on all 1. UTILIZE 4 11116"DEEP BOX WITH REQUIRED MUDRING AND CONDUIT TO workmanship, materials and equipment and agree to 9. CUTTING AND PATCHING: repair or replace all such defective items promptly that Do all drilling and cutting as necessary for installation of may occure during the warranty period; including repair equipment or conduit. Cutting or drilling of structure is only or replacement of the premises that may be damaged permitted with prior approval of the owner and structural due to faulty work and materials furnished under engineer. contract. Where cutting and patching of work is necessary, use the G. ALL CONDUIT/RACEWAY/CABLES TO BE CONCEALED IN WALLS OR ABOVE same materials, workmanship and finish to neatly match all SUPPORT OF CABUNG WHERE CABLE TRAY IS NOT surrounding work. CONDUCTOR(S) CIRCUITING & GENERAL SYMBOL SPECIAL SYSTEMS SYMBOL SCHEDULE SCHEDULE NOTE: ALL SYMBOLS MAY NOT BE USED NOTE: ALL SYMBOLS MAY NOT BE USED SYMBOL DESCRIPTION SYMBOL DESCRIPTION O KEYED NOTE REFERENCE DA DATA OUTLET; _= # OF DATA CABLES, X=CONDUIT B. CONDUITS FOR COMMUNICATIONS CABLING SHALL HAVE A MAXIMUM BEND SIZE (SEE NOTES BELOW) DEMOLITION EQUIPMENT, DEVICES, ETC. BRANCH CIRCUIT HOME -RUN TO PANEL CEILING MOUNTED DATA OUTLET; _ # OF DATA C. ALL COMMUNICATIONS CONDUITS SHALL BE TERMINATED WITH AN INSULATED NON-METALLIC BUSHING AT BOTH ENDS. INDICATED PANEL AND -D-X CABLES, X=CONDUIT SIZE (SEE NOTES BELOW) A-1,3,5 -., CIRCUIT AND SHALL BE SIZED AT LEASED 12X THE LARGEST CONDUIT DIAMETER IN A-1,3,5 3/4"C:6#12,1#12G DESIGNATIONS 3/4"C:6#12,1#12G DESCRIPTION PATHWAY FOR THE DATA CABLING DOES NOT CREATE CABLE LENGTHS TO EXCEEDS THE LENGTH OF 295FT FROM OUTLET TO PATCH PANEL, THIS QTY &SIZE OF EQUIPMENT TA TELEPHONE OUTLET; _ # OF TELEPHONE CABLES, GROUND CONDUCTOR - X=CONDUIT SIZE (SEE NOTES BELOW) DUPLEX RECEPTACLE TELEPHONE/DATA OUTLET; _= # OF QTY & SIZE OF NEUTRAL AND PROJECT GENERAL NOTES: PHASE CONDUCTOR(S) TI D -X TELEPHONE/DATA CABLES, X=CONDUIT SIZE (SEE GFCI-TYPE DUPLEX RECEPTACLE A. REFER TO ARCHITECTURAL REFLECTED CEIUNG PLAN(S) FOR EXACT NOTES BELOW) SIZE OF CONDUIT TELEPHONE AND DATA OUTLET NOTES: FIXTURE LOCATIONS, CEILING TYPES, ETC. TICK MARKS GFCI-TYPE DOUBLE -DUPLEX RECEPTACLE 1. UTILIZE 4 11116"DEEP BOX WITH REQUIRED MUDRING AND CONDUIT TO EQUIPMENT GROUNDING ABOVE NEAREST ACCESSIBLE CEILINGICABLE TRAY, TERMINATE WITH D. SUPPORT ALL LIGHT FIXTURES INDEPENDENT OF CEILING. E. ELECTRICAL CONTRACTOR SHALL OBTAIN ALL APPLICABLE PERMITS FOR ~ CONDUCTOR INSULATED THROAT BUSHING. PROVIDE QTY OF CABLES INDICATED WORK AND PAY ASSOCIATED FEES. — NEUTRAL CONDUCTOR(S) FROM OUTLETTO NEARESTTELEIDATA ROOM. SEE DWGS FOR WP WEATHERPROOF (UL LISTED ELECTRONIC BALLASTS. ADDITIONAL INFORMATION. UTILIZE J -HOOKS 3FT ON CENTER FOR G. ALL CONDUIT/RACEWAY/CABLES TO BE CONCEALED IN WALLS OR ABOVE PHASE AND/OR SWITCH -LEG SUPPORT OF CABUNG WHERE CABLE TRAY IS NOT CONDUCTOR(S) INSTALLEDISPECIFIED. 2. CONDUIT SIZE ('X' FROM ABOVE); 2=112", 3=314", 4=1", 5=1-114" OR (2)1" THOROUGHLY INVESTIGATE THE EXISTING CONDITIONS, AS THEY RELATE BRANCH CIRCUIT/FEEDER CONCEALED IN CEILING OR WALL 3. BLANK (NO LABEL) = 4-11116" DEEP BOX WITH REQUIRED MUDRING AND 1" CONDUIT TO ABOVE NEAREST ACCESSIBLE CEILING/CABLE TRAY, TERMINATE WITH INSULATEDTHROAT BUSHING, PROVIDE PULL STRING. THE BASE BID TO ADEQUATELY ACCOMMODATE THESE CONDITIONS. BRANCH CIRCUIT/FEEDER CONCEALED UNDERGROUND OR FLOOR (UNLESS OTHERWISE NOTED) ;SO�ONAL FN0i Q�oF ��G1 S TERFo'vF�� 13053 s rlF OF A. MEP el ORIGINAL SIGNED BY: SHAWN A. MEADOR DATE ORIGINAL SIGNED: 06/23/17 ON FILE AT: \PAYNE ENGINEERING INC. r llll� `t ©2017 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460 P.E. JOB #1749 FRAYME n ig neering Inc. 1823 E. Center Pocatello, Idaho 83201 tel (208) 232-4439 fax (208) 232-1435 DOCUMENT STATUS STATUS I DATE REVISION SCHEDULE NO. DESCRIPTION DATE DRAWN BY: SAM CHECKED BY: TEP PROJECT NAME: SNO 233 TEACHING STUDIOS PROJECT NO. 11285 SHEET NAME: ELECTRICAL COVER SHEET SHEET NUMBER: EGO01 NEW EQUIPMENT, DEVICES, ETC. GENERAL SPECIAL SYSTEM NOTES: — — — — — — — — — — EXISTING EQUIPMENT, DEVICES, ETC. A. COMMUNICATIONS CABLES SHALL HAVE BENDS NO GREATER THAN 90 DEG. B. CONDUITS FOR COMMUNICATIONS CABLING SHALL HAVE A MAXIMUM BEND — — — — — DEMOLITION EQUIPMENT, DEVICES, ETC. RADIUS NOTMORETHAN 10XTHE DIAMETEROF THE CONDUIT. C. ALL COMMUNICATIONS CONDUITS SHALL BE TERMINATED WITH AN INSULATED NON-METALLIC BUSHING AT BOTH ENDS. POWER SYMBOL SCHEDULE D. COMMUNICATIONS CONDUITS SHALL HAVE NO MORE THAN (2) 90-S WITHOUT A PULLBOX. PULL BOXES SHALL BE LOCATED IN ACCESSIBLE LOCATIONS AND SHALL BE SIZED AT LEASED 12X THE LARGEST CONDUIT DIAMETER IN NOTE: ALL SYMBOLS MAY NOT BE USED LENGTH AND MIN, 4" DEEP AND 8" WIDE. E. IT SHALL BE THE RESPONSIBILITY OF THE E.C. TO INSURE THAT THE SYMBOL DESCRIPTION PATHWAY FOR THE DATA CABLING DOES NOT CREATE CABLE LENGTHS TO EXCEEDS THE LENGTH OF 295FT FROM OUTLET TO PATCH PANEL, THIS CEILING MOUNTED DUPLEX RECEPTACLE (COORDINATE PLACEMENT WITH INCLUDES SERVICE LOOPS AND PATCH CORDS. F. WHERE CABLE TRAY IS UTILIZED IN THE PROJECT. COMMUNICATION CEIUNG EQUIPMENT PRIOR TO ROUGH4N) CONDUITS ENDING AT THE CABLE TRAY SHALL EXTEND 1" OVER THE SIDE INTO THE TRAY. DUPLEX RECEPTACLE PROJECT GENERAL NOTES: (h GFCI-TYPE DUPLEX RECEPTACLE A. REFER TO ARCHITECTURAL REFLECTED CEIUNG PLAN(S) FOR EXACT TF DOUBLE -DUPLEX RECEPTACLE FIXTURE LOCATIONS, CEILING TYPES, ETC. B. CONFIRM EXACT LOCATIONS OF ALL TELEPHONE/DATA OUTLETS NTH OWNER PRIOR TO ROUGH -IN. C. LOCATE SWITCHES, OUTLETS, ETC., SHOWN AT ROOM ENTRY DOORWAYS, GFCI-TYPE DOUBLE -DUPLEX RECEPTACLE AS CLOSE TO DOOR FRAME AS POSSIBLE, SO AS NOT RO INTERFERE WITH ROOM CABINETS, ETC. RECEPTACLE AND EQUIPMENT SUBSCRIPTS D. SUPPORT ALL LIGHT FIXTURES INDEPENDENT OF CEILING. E. ELECTRICAL CONTRACTOR SHALL OBTAIN ALL APPLICABLE PERMITS FOR AC ABOVE COUNTER WORK AND PAY ASSOCIATED FEES. TR UL LISTED TAMPER-RESISTANT F. MAINTAIN 24" MIN. CLEARANCE FROM ALL COMMUNICATIONS CABUNG AND WP WEATHERPROOF (UL LISTED ELECTRONIC BALLASTS. WEATHER -RESISTANT) G. ALL CONDUIT/RACEWAY/CABLES TO BE CONCEALED IN WALLS OR ABOVE +42" MOUNTING HEIGHT AFF ORAFG CEILINGS. IF ANY SURFACE WORK IS NECESSARY, IT SHALL BE APPROVED BY THE ARCHITECT/ENGINEER PRIOR TO INSTALLATION. H. ELECTRICAL CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID AND THOROUGHLY INVESTIGATE THE EXISTING CONDITIONS, AS THEY RELATE TO THE SCOPE OF WORK DESCRIBED. MAKE NECESSARY PROVISIONS IN THE BASE BID TO ADEQUATELY ACCOMMODATE THESE CONDITIONS. 1. JUNCTION BOXES FOR UGHTING CIRCUITING MAY NOT BE SHOWN FOR CLARITY. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING AND INSTALLING ALL JUNCTION BOXES REQUIRED FOR CIRCUITING OF ALL LIGHT FIXTURES THAT ARE NOT LISTED FOR'THROUGH-BRANCH CIRCUIT WIRING." ;SO�ONAL FN0i Q�oF ��G1 S TERFo'vF�� 13053 s rlF OF A. MEP el ORIGINAL SIGNED BY: SHAWN A. MEADOR DATE ORIGINAL SIGNED: 06/23/17 ON FILE AT: \PAYNE ENGINEERING INC. r llll� `t ©2017 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460 P.E. JOB #1749 FRAYME n ig neering Inc. 1823 E. Center Pocatello, Idaho 83201 tel (208) 232-4439 fax (208) 232-1435 DOCUMENT STATUS STATUS I DATE REVISION SCHEDULE NO. DESCRIPTION DATE DRAWN BY: SAM CHECKED BY: TEP PROJECT NAME: SNO 233 TEACHING STUDIOS PROJECT NO. 11285 SHEET NAME: ELECTRICAL COVER SHEET SHEET NUMBER: EGO01 LEVEL 2 - PARTIAL FLOOR PLAN SCALE: 1/16" = 1'-0" 32' NORTH ©2017 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460 P.E. JOB #1749 FRAYME n ig neering Inc. 1823 E. Center Pocatello, Idaho 83201 tel(208)232-4439 fax (208) 232-1435 DOCUMENT STATUS STATUS I DATE I REVISION SCHEDULE I DRAWN BY: SAM CHECKED BY: TEP PROJECT NAME: SNO 233 TEACHING STUDIOS �Ss\p N A L FNCi G\ST'6p' Q� PROJECT NO. 11285 13053 SHEET NAME: LEVEL 2 - PARTIAL s/Y ATF o f �oPoo� FLOOR PLAN A. MEP 'ORIGINAL SIGNED BY: SHAWN A. MEADOR DATE ORIGINAL SIGNED: 06/23/17 ON FILE AT: PAYNE ENGINEERING INC. SHEET NUMBER: EGO02 2 of 5 N 00 s N KEY NOTES: # ) I DEMOLITION GENERAL NOTES: EXISTING PLAN - ELECTRICAL SCALE: 1/4" = 1'-0" ORIGINAL SIGNED BY: SHAWN A. MEADOR DATE ORIGINAL SIGNED: 06/23/17 ON FILE AT: PAYNE ENGINEERING INC. SHEET NUMBER: ED101 3 OF 5 1 ALL EXISTING ELECTRICAL DEVICES WITHIN THIS AREA IS A. IN GENERAL, UNLESS SPECIFICALLY INDICATED OTHERWISE, TO BE REMOVED, UNLESS INDICATED OTHERWISE; ALL EXISTING ELECTRICAL EQUIPMENT SHOWN SHALL BE yl INCLUDING BUT NOT LIMITED TO: OUTLETS, LIGHTS, REMOVED. WHEN EXISTING SWITCH AND OR OUTLET BOXES 1 SWITCHES, DATA, ETC. MAINTAIN EXISTING LIGHTING AND FALL WITHIN OR NEAR NEW OUTLETS/SWITCHES SHOWN IN RECEPTACLE CIRCUIT WITHIN AREA TO BE REUSED FOR NEW DESIGN, THE E.C. MAY UTILIZE THE EXISTING ROUGH -IN, NEW DEVICES. ELECTRICAL CONTRACTOR SHALL MAINTAIN/RE-ESTABLISH CONTINUITY TO ALL ETC. IN LIEU OF INSTALLING NEW. CONTRACTOR MUST HOWEVER MAINTAIN ELECTRICAL CONTINUITY TO , ` • DOWNSTREAM EQUIPMENT/DEVICES THAT ARE TO DOWNSTREAM EQUIPMENT TO REMAIN. ELECTRICAL REMAIN. WHERE EXISTING SWITCH OR OUTLET BOXES CONTRACTOR MAY UTILIZE ANY EXISTING RACEWAYS FALL WITHIN OR NEAR NEW OUTLET/SWITCH LOCATIONS. WHERE THEY ARE COMPATIBLE WITH NEW ELECTRICAL CONTRACTOR MAY UTILIZE EXISTING DESIGN/SYSTEMS. PROVIDE ALL NEW DEVICES AND ROUGH -IN, ETC. IN LIEU OF INSTALLING NEW. COVERS. 2 EXISTING DEVICE TO REMAIN; LOCATE, PROTECT AND B. ALL EXISTING ELECTRICAL MAY NOT APPEAR ON THESE MAINTAIN FUNCTIONALITY DURING CONSTRUCTION. REMOVE AND RE -INSTALL DEVICE AS NEEDED FOR C. PLANS, HOWEVER THE ABOVE INFORMATION APPLIES. PROVIDE AND INSTALL BLANK COVERS ON ALL UNUSED ©2017 BYU-IDAHO 525 SOUTH CENTER STREET CONSTRUCTION. SWITCH/OUTLET/J-BOXES WHERE REQUIRED. REXBURG, IDAHO 83460 3 IF EXISTING DATA CABLING FROM DEMOLISHED OUTLETS IS OF ADEQUATE LENGTH TO SERVICE NEW DATA OUTLET D. ALL WALL DEVICES THAT ARE EXISTING TO REMAIN, SHALL BE ADAPTED TO NEW WALL COVERINGS, REFER TO LOCATIONS, E.C. SHALL PULL-BACK CABLING TO AN ARCHITECTURAL DRAWINGS FOR EXACT WALL LOCATIONS, APPROPRIATE LOCATION AND RE -INSTALL TO NEW OUTLET THICKNESS, ETC. LOCATIONS INDICATED ON DRAWINGS. PROVIDE # OF E. PRIOR TO THE START OF ANY DEMOLITION WORK, DATA DROPS AS SPECIFIED ON NEW DRAWINGS. ALL DATA DISCONNECTING ANY POWER AND OR TELE/DATA SYSTEMS, CABLING THAT CANNOT BE RE -USED SHALL BE REMOVED THE CONTRACTOR SHALL COORDINATE DOWN-TIME WITH IN ITS ENTIRETY BACK TO ITS SOURCE. THE OWNER. O 4 EXISTING WIRELESS ACCESS POINT SHALL BE REMOVE, STORED AND RE -INSTALLED BY THE CONTRACTOR. REFER TO NEW DRAWINGS FOR LOCATION. F. G. H. REFER TO ARCHITECTURAL PLANS FOR EXTENT OF DEMOLITION, DETAILS, ETC. REMOVE OR RELOCATE ELECTRICAL AS NECESSARY FOR NEW WORK. WHERE EXISTING CIRCUITS ARE TO BE RE -USED, EXTEND AS NECESSARY. MAINTAIN ELECTRICAL CONTINUITY TO P.E. JOB #1749 �pAYNE — — Vk — — n �l` � O I. J. DOWNSTREAM EQUIPMENT TO REMAIN. EXISTING SHOWN TO REMAIN, MAY NEED TO BE REMOVED AND RE -INSTALLED ONLY AS NECESSARY FOR EXTENDING RE MODIFICATION OF EXISTING CIRCUITS WIRING. REMOVE ALL UNUSED EQUIPMENT WIRING,, C CONDUIT AND BOXES IN ALL AREAS. ABANDON ONLY IN CONCEALED En ig nearing Inc. 1823 E. Center Pocatello, Idaho 83201 tel (208) 232-4439 fax (208) 232-1435 DOCUMENT STATUS <� — — _ I \/ �I I O - - - --- --- Q 4k O K. L. AREAS. CONTRACTOR MY UTILIZE ANY EXISTING CONDUIT WHERE COMPATIBLE WITH NEW DESIGN, AND IF IN GOOD CONDITION AND COMPLIES WITH SPECIFICATIONS. WHEN ANY MODIFICATIONS ARE MADE TO ANY EXISTING ELECTRICAL PANEL TO REMAIN, CONTRACTOR TO PROVIDE STATUS DATE / \ I M. NEW TYPE WRITTEN INDEX TO REFLECT ALL NEW AND EXISTING LOADS. REMOVE ALL EQUIPMENT, RACEWAYS, CABLES,ETC. NOT REVISION SCHEDULE \/ I I \/ I I \/ I I \/ I== USED IN FINISHED AREAS. NO. DESCRIPTION DATE a I \/ I I \/ /L—�—.J\ I POWER/DATA UTILITY POLE (7 7\ I \/ I D UTILITY POLE uTIPOWER/DATI \/ \ /L—� �� I �SS\ONALFiyci STEy? o, DRAWN SAM CHECKED BY: TEP PROJECT NAME: SNO 233 TEACHING STUDIOS PROJECT NO. 11285 — _ O O - - _ _ — — - O yik - O it - - 13053 spy Pio sy F of �o O� A. M�pO SHEET AME. EXISTING PLAN E - ELECTRICAL EXISTING PLAN - ELECTRICAL SCALE: 1/4" = 1'-0" ORIGINAL SIGNED BY: SHAWN A. MEADOR DATE ORIGINAL SIGNED: 06/23/17 ON FILE AT: PAYNE ENGINEERING INC. SHEET NUMBER: ED101 3 OF 5 LIGHTING FIXTURE SCHEDULE TYPE FIXTURE DESCRIPTION MOUNTING VOLTS LAMPS MFGR. CATALOG # NOTES F1 2X2 LAY -IN ARCHITECTURAL TROFFER RECESSED 120-277 LED-4000LM-4000K LITHONIA 2BLT2-40L-SDP-EZ1-LP840 LIGHTING OCCUPANCY SENSOR SCHEDULE TYPE MFGR. CATALOG # I DESCRIPTION I NOTES WALL SENSORS WDD I SENSOR SWITCH WSX-PDT-D-SA DUAL -TECHNOLOGY, 0-10V DIMMING, MANUAL ON COLOR TO MATCH WIRING DEVICES KEY NOTES: 1 CONNECT TO EXISTING LIGHTING CIRCUIT THAT ORIGINATED IN AREA; FIELD LOCATION HOMERUN LOCATION. LIGHTING PLAN SCALE: 1/4" = V-0" m 1 WDD WDD WDD 0" 4' 8' NORTH SS\O N A L FN 13053 '�N/v A. MEP ORIGINAL SIGNED BY: SHAWN A. MEADOR DATE ORIGINAL SIGNED: 06/23/17 ON FILE AT: \PAYNE ENGINEERING INC. ©2017 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460 P.E. JOB #1749 FAYIVH n ig neering Inc. 1823 E. Center Pocatello, Idaho 83201 tel (208) 232-4439 fax (208) 232-1435 DOCUMENT STATUS I REVISION SCHEDULE NO. DESCRIPTION DATE DRAWN BY: SAM CHECKED BY: TEP PROJECT NAME: SNO 233 TEACHING STUDIOS PROJECT NO. 11285 SHEET NAME: LIGHTING PLAN SHEET NUMBER: EE1 01 4 OF 5 KEY NOTES: C 1 EXISTING DEVICE TO REMAIN; LOCATE, PROTECT AND MAINTAIN FUNCTIONALITY DURING CONSTRUCTION. REMOVE AND RE—INSTALL DEVICE AS NEEDED FOR CONSTRUCTION. 2 EXISTING WIRELESS ACCESS POINT SHALL BE REMOVE, STORED AND RE—INSTALLED BY THE CONTRACTOR. REFER TO NEW DRAWINGS FOR LOCATION. 2D-3 /771 2 POWER & SPECIAL SYSTEMS PLAN SCALE: 1/4" = V-0" 8' 9— t NORTH �S\O N AL S TERF�'�'_�� 13053 sy ryTF O F �0�' o� �wN A. MEP ORIGINAL SIGNED BY: SHAWN A. MEADOR DATE ORIGINAL SIGNED: 06/23/17 ON FILE AT: PAYNE ENGINEERING INC. 02017 BYU—IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO 83460 P.E. JOB #1749 FFFAYIVH n ig neering Inc. 1823 E. Center Pocatello, Idaho 83201 tel (208) 232-4439 fax (208) 232-1435 DOCUMENT STATUS STATUS I DATE REVISION SCHEDULE NO. DESCRIPTION DATE DRAWN BY: SAM CHECKED BY: TEP PROJECT NAME: SNO 233 TEACHING STUDIOS PROJECT NO. 11285 SHEET NAME: POWER AND SPECIAL SYSTEMS PLAN SHEET NUMBER: EE1 02 5 OF 5