HomeMy WebLinkAboutPLANS 2 - 17-00114 - 323 S 3rd E - SolarS H E E T I N D E X P V 1 - C O V E R S H E E T P V 2 - P R O P E R T Y P L A N P V 3 - S I T E P L A N P V 4 - E Q U I P M E N T & A T T A C H M E N T D E T A I L P V 5 - E L E C T R I C A L S I N G L E L I N E D I A G R A M P V 6 - E L E C T R I C A L C A L C U L A T I O N S & S T R I N G D I A G R A M P V 7 - M B D C A L C S . ( I F N E E D E D ) P V 8 - L A B E L S & L O C A T I O N S P V 9 - P L A C A R D GENERAL NOTES O C C U P A N C Y - R 3 C O N S T R U C T I O N - V - B Z O N I N G : R E S I D E N T I A L ASC E 7 - 1 0 W I N D S P E E D : 1 0 5 M P H GRO U N D S N O W L O A D : S i t e - S p e c i f i c P S F EXP O S U R E C A T E G O R Y : C SEIS M I C D E S I G N C A T E G O R Y : D SCOP E O F W O R K DC S Y S T E M S I Z E : 5 . 9 4 k W D C ROO F T Y P E : C o m p S h i n g l e ANC H O R E D O N M A X 4 8 I N C H C E N T E R S U S I N G U L L I S T E D R A C K I N G SY S T E M T O S P E C . UV R E S I S T A N T C A B L E T I E S ( N O T Z I P T I E S ) U S E D F O R P E R M A N E N T WIR E M A N A G E M E N T O F F T H E R O O F S U R F A C E I N A C C O R D A N C E WIT H N E C 1 1 0 . 2 , 1 1 0 . 3 ( A - B ) . 3 0 0 . 4 SOLA D E C K J U N C T I O N B O X E S M O U N T E D F L U S H W / R O O F S U R F A C E WIL L B E U S E D I F C O N D U I T R U N D E T E R M I N E D I N T H E F I E L D T O B E RA N T H R O U G H A T T I C . D C C O N D U C T O R S S I Z E D W I T H D E R A T E S T O 1/2" A B O V E R O O F S U R F A C E P E R N E C 3 1 0 . 1 5 ( B ) ( 3 ) ( C ) MOD U L E : ( 2 2 ) H y u n d a i H i S - S 2 7 0 R G B l a c k INVE R T E R ( S ) : S o l a r E d g e S E 5 0 0 0 A - U S , - - - - RAC K I N G : I r o n R i d g e X R 1 0 P V M o u n t i n g & R a c k i n g S y s t e m AE R I A L V I E W SITE NOTES1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS.2. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AN UTILITYINTERACTIVE SYSTEM WITH NO STORAGE BATTERIES.3. THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, ORBUILDING ROOF VENTS.4. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICALEQUIPMENT WILL BE PROVIDED AS PER SECTION [NEC 110.26]5. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGEBETWEEN THE GROUNDING ELECTRODE AND THE PANEL (OR INVERTER) IF SMALLER THAN #6AWG COPPER WIRE PER NEC 250-64B. THE GROUNDING ELECTRODE CONDUCTOR WILL BECONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT PER[NEC 250.64C.]6. ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITHTHIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOFCOVERING SHALL SERVE TO PROTECT THE BUILDING OR STRUCTURE.7. RIGID CONDUIT (AND/OR NIPPLES) MUST HAVE A PULL BUSHING TO PROTECT WIRES.8. BOLTED CONNECTION REQUIRED IN DC DISCONNECTS ON THE WHITE GROUNDEDCONDUCTOR (USE POLARIS BLOCK OR NEUTRAL BAR)9. ANY CONNECTION ABOVE LIVE PARTS MUST BE WATERTIGHT. REDUCING WASHERSDISALLOWED ABOVE LIVE PARTS, MEYERS HUBS RECOMMENDEDSOLAR CONTRACTOR1. MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646, IEC61730.2. IF APPLICABLE, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE MARKED GROUNDINGLUG HOLES PER THE MANUFACTURERS' INSTALLATION REQUIREMENTS.3. AS INDICATED BY DESIGN, OTHER NRTL LISTED MODULE GROUNDING DEVICES MAY BE USEDIN PLACE OF STANDARD GROUNDING LUGS AS SHOWN IN MANUFACTURER DOCUMENTATIONAND APPROVED BY THE AHJ.4. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARENOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS.5. CONDUIT POINT OF PENETRATION FROM EXTERIOR TO INTERIOR TO BE INSTALLED ANDSEALED WITH A SUITABLE SEALING COMPOUND.6. DC WIRING LIMITED TO MODULE FOOTPRINT W/ ENPHASE AC SYSTEM.7. ENPHASE WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/SUITABLE WIRING CLIPS.8. MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FORVOC UNLESS NOT AVAILABLE.9. ALL INVERTERS, MOTOR GENERATORS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS,AC PHOTOVOLTAIC MODULES, SOURCE CIRCUIT COMBINERS, AND CHARGE CONTROLLERSINTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND LISTED FORTHE APPLICATION PER 690.4 (D).10. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE.EQUIPMENT LOCATIONS1. ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY [NEC 110.26].2. EQUIPMENT INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATINGTEMPERATURE AS SPECIFIED BY [NEC 690.31 (A)-(B)] AND [NEC TABLE 310.15 (B)(2)(C)].3. ADDITIONAL AC DISCONNECTS SHALL BE PROVIDED WHERE THE INVERTER IS NOT ADJACENTTO THE UTILITY AC DISCONNECT, OR NOT WITHIN SIGHT OF THE UTILITY AC DISCONNECT.4. ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TONEC APPLICABLE CODES.5. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHENAPPROPRIATE.1. ALL WORK SHALL COMPLY WITH 2014 NATIONAL ELECTRIC CODE (NEC), 2014 NATIONALBUILDING CODE (NBC), 2015 INTERNATIONAL BUILDING CODE (IBC), 2015 INTERNATIONALPLUMBING CODE (IBC), AND ALL STATE AND LOCAL BUILDING, ELECTRICAL, AND PLUMBINGCODES.2. DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. D R A W I N G B Y D A T E P R O J E C T N U M B E R S H E E T N A M E P A G E N U M B E R R E V I S I O N 1 2 2 0 S . 6 3 0 E S T E . 4 3 0 A M E R I C A N F O R K , U T 8 4 0 0 3 8 0 0 - 3 7 7 - 4 4 8 0 W W W . B L U E R A V E N S O L A R . C O M C O N F I D E N T I A L - T H E I N F O R M A T I O N H E R E I N C O N T A I N E D S H A L L N O T B E U S E D F O R T H E B E N E F I T O F A N Y O N E E X C E P T B L U E R A V E N S O L A R N O R S H A L L I T B E D I S C L O S E D I N W H O L E O R I N P A R T T O O T H E R S O U T S I D E R E C I P I E N T S O R G A N I Z A T I O N , E X C E P T I N C O N N E C T I O N W I T H T H E S A L E A N D U S E O F T H E R E S P E C T I V E E Q U I P M E N T , W I T H O U T T H E W R I T T E N P E R M I S S I O N O F B L U E R A V E N S O L A R L L C . P V 1 C O V E R S H E E T S a s a M a c u r a 2 8 0 7 1 1 4 4 A p r i l 2 7 , 2 0 1 7 A SITE INFORMATION: DC SYSTEM SIZE: David Peck 323 South 3rd East 5.94 Rexburg, Idaho 83440 kW DC PROJECT MANAGER: SCOTT GURNEY 385-498-4401 CONTRACTOR: BLUE RAVEN SOLAR 800.377.4480 N D C D C D C D C D C D C D C D C D C D C D C D C D C D C D C D C D C D C D C D C D C D C D C D C D C D C DCDC DCDC DCDC DCDC DCDC DCDC DCDC DCDC D C D C M I N V J B A C FRONT OF HOME M P 1 A Z I M U T H : 1 8 1 ° P I T C H : 1 8 ° M P 2 A Z I M U T H : 9 1 ° P I T C H : 2 3 ° 323 South 3rd EastDC SYSTEM SIZE: 5.94 kW DCROOF TYPE: Comp Shingle(22) Hyundai HiS-S270RG Black SolarEdge SE5000A-US,----INVERTER 2 1 ' S C A L E : 3 / 6 4 " = 1 ' - 0 " 0 ' 4 2 ' 1 2 8 ' 6 4 ' L E G E N D A C M I N V E R T E R & D C D I S C O N N E C T I N V A C D I S C O N N E C T U T I L I T Y M E T E R / S E R V I C E P A N E L P V R E V E N U E M E T E R J B J U N C T I O N B O X P R O P E R T Y L I N E F I R E S E T B A C K P V S O L A R M O D U L E E M T C O N D U I T R U N ( T O B E D E T E R M I N E D I N F I E L D ) P V W I R E S T R I N G P V S U B ( E ) S U B P A N E L L C ( N ) L O A D C E N T E R D A T E D R A W I N G B Y P R O J E C T N U M B E R S H E E T N A M E P A G E N U M B E R R E V I S I O N 1 2 2 0 S . 6 3 0 E S T E . 4 3 0 A M E R I C A N F O R K , U T 8 4 0 0 3 8 0 0 - 3 7 7 - 4 4 8 0 W W W . B L U E R A V E N S O L A R . C O M C O N F I D E N T I A L - T H E I N F O R M A T I O N H E R E I N C O N T A I N E D S H A L L N O T B E U S E D F O R T H E B E N E F I T O F A N Y O N E E X C E P T B L U E R A V E N S O L A R N O R S H A L L I T B E D I S C L O S E D I N W H O L E O R I N P A R T T O O T H E R S O U T S I D E R E C I P I E N T S O R G A N I Z A T I O N , E X C E P T I N C O N N E C T I O N W I T H T H E S A L E A N D U S E O F T H E R E S P E C T I V E E Q U I P M E N T , W I T H O U T T H E W R I T T E N P E R M I S S I O N O F B L U E R A V E N S O L A R L L C . P V 2 P R O P E R T Y P L A N A S a s a M a c u r a 2 8 0 7 1 1 4 4 A p r i l 2 7 , 2 0 1 7 SITE INFORMATION: DC SYSTEM SIZE: David Peck 323 South 3rd East 5.94 Rexburg, Idaho 83440 kW DC PROJECT MANAGER: SCOTT GURNEY 385-498-4401 CONTRACTOR: BLUE RAVEN SOLAR 800.377.4480 1 9 7 ' - 8 " 88'-6" 2 7 ' - 1 0 " A C d i s c o n n e c t t o b e l o c a t e d w i t h i n 1 0 ' o f U t i l i t y M e t e r . A A N D C D C D C D C D C D C D C D C D C D C D C D C D C D C D C D C D C D C D C D C D C D C D C D C D C D C DCDC DCDC DCDC DCDC DCDC DCDC DCDC DCDC D C D C M I N V J B A C FRONT OF HOME M P 1 A Z I M U T H : 1 8 1 ° P I T C H : 1 8 ° M P 2 A Z I M U T H : 9 1 ° P I T C H : 2 3 ° 8 ' 1 6 ' S C A L E : 1 / 1 6 " = 1 ' - 0 " 0 ' 3 2 ' 4 ' L E G E N D A C M I N V E R T E R & D C D I S C O N N E C T I N V A C D I S C O N N E C T U T I L I T Y M E T E R / S E R V I C E P A N E L P V R E V E N U E M E T E R J B J U N C T I O N B O X P R O P E R T Y L I N E F I R E S E T B A C K P V S O L A R M O D U L E E M T C O N D U I T R U N ( T O B E D E T E R M I N E D I N F I E L D ) P V W I R E S T R I N G P V S U B ( E ) S U B P A N E L L C ( N ) L O A D C E N T E R DC SYSTEM SIZE: 5.94 kW DCROOF TYPE: Comp Shingle(22) Hyundai HiS-S270RG Black SolarEdge SE5000A-US,----INVERTER D R A W I N G B Y D A T E P R O J E C T N U M B E R S H E E T N A M E P A G E N U M B E R R E V I S I O N 1 2 2 0 S . 6 3 0 E S T E . 4 3 0 A M E R I C A N F O R K , U T 8 4 0 0 3 8 0 0 - 3 7 7 - 4 4 8 0 W W W . B L U E R A V E N S O L A R . C O M C O N F I D E N T I A L - T H E I N F O R M A T I O N H E R E I N C O N T A I N E D S H A L L N O T B E U S E D F O R T H E B E N E F I T O F A N Y O N E E X C E P T B L U E R A V E N S O L A R N O R S H A L L I T B E D I S C L O S E D I N W H O L E O R I N P A R T T O O T H E R S O U T S I D E R E C I P I E N T S O R G A N I Z A T I O N , E X C E P T I N C O N N E C T I O N W I T H T H E S A L E A N D U S E O F T H E R E S P E C T I V E E Q U I P M E N T , W I T H O U T T H E W R I T T E N P E R M I S S I O N O F B L U E R A V E N S O L A R L L C . P V 4 E Q U I P . D E T A I L S a s a M a c u r a 2 8 0 7 1 1 4 4 A p r i l 2 7 , 2 0 1 7 A SITE INFORMATION: DC SYSTEM SIZE: David Peck 323 South 3rd East 5.94 Rexburg, Idaho 83440 kW DC PROJECT MANAGER: SCOTT GURNEY 385-498-4401 CONTRACTOR: BLUE RAVEN SOLAR 800.377.4480 C H I M N E Y CHIMNEY A C d i s c o n n e c t t o b e l o c a t e d w i t h i n 1 0 ' o f U t i l i t y M e t e r . A A I r o n R i d g e X R 1 0 P V R A I L I R O N R I D G E F L A S H F O O T 4 ' - 0 M A X . " 1 ' - 3 " M A X . H P V 4 I r o n R i d g e X R 1 0 P V R A I L P V M O D U L E 4 ' - 0 " M A X . " 1 ' - 1 1 " M A X . E P V 4 G P V 4 D E T A I L , S I D E V I E W S c a l e : 3 / 8 " = 1 ' - 0 " D E T A I L , F R O N T V I E W S c a l e : 3 / 8 " = 1 ' - 0 " 1 8 ° 1 ' - 3 " M A X . 4 ' - 0 M A X . " R O O F T Y P E : C o m p S h i n g l e R O O F F R A M I N G T Y P E : R a f t e r s R O O F F R A M I N G S I Z E : 2 x 6 R O O F F R A M I N G S P A C I N G : 2 4 " O . C . A S C E 7 - 1 0 W I N D S P E E D : 1 0 5 M P H G R O U N D S N O W L O A D : S i t e - S p e c i f i c P S F (E) ROO F MEMBR A N E IRONRI D G E FLASHF O O T ASSEMB L Y PV MOD U L E (E) BUIL D I N G STRUCT U R E DETAIL, STANDOFFScale: 3" = 1'-0"H Hyundai H i S - S 2 7 0 R G B l a c k 2 12" MIN.DEPTH5/16" S T A I N L E S S S T E E L L A G BOLT A N D F L A T W A S H E R 4"Iron Rid g e X R 1 0 P V I R O N R I D G E RAIL PV ARRAY STRUCTURAL CALCULATIONSPV MODULE COUNT:ARRAY AREA:ARRAY WEIGHT:DISTRIBUTED LOAD:22 MODULESModule Count X 17.51ft² = 385.2ft²Array Weight ÷ Array Area = 2.86 lbs/ft ² Module Count x 50lbs = 1100.0lbs #OF ATTACHMENT POINTS:48POINT LOAD:Array Weight ÷ Attachments = 22.9lbs/ a t t a c h m e n t ROOF AREA:2373ft²%OF ARRAY/ROOF:16.2% D R A W I N G B Y D A T E P R O J E C T N U M B E R S H E E T N A M E P A G E N U M B E R R E V I S I O N 1 2 2 0 S . 6 3 0 E S T E . 4 3 0 A M E R I C A N F O R K , U T 8 4 0 0 3 8 0 0 - 3 7 7 - 4 4 8 0 W W W . B L U E R A V E N S O L A R . C O M C O N F I D E N T I A L - T H E I N F O R M A T I O N H E R E I N C O N T A I N E D S H A L L N O T B E U S E D F O R T H E B E N E F I T O F A N Y O N E E X C E P T B L U E R A V E N S O L A R N O R S H A L L I T B E D I S C L O S E D I N W H O L E O R I N P A R T T O O T H E R S O U T S I D E R E C I P I E N T S O R G A N I Z A T I O N , E X C E P T I N C O N N E C T I O N W I T H T H E S A L E A N D U S E O F T H E R E S P E C T I V E E Q U I P M E N T , W I T H O U T T H E W R I T T E N P E R M I S S I O N O F B L U E R A V E N S O L A R L L C . P V 4 E Q U I P . D E T A I L S a s a M a c u r a 2 8 0 7 1 1 4 4 A p r i l 2 7 , 2 0 1 7 A SITE INFORMATION: DC SYSTEM SIZE: David Peck 323 South 3rd East 5.94 Rexburg, Idaho 83440 kW DC PROJECT MANAGER: SCOTT GURNEY 385-498-4401 CONTRACTOR: BLUE RAVEN SOLAR 800.377.4480 IRONRI D G E I G M I D C L A M P PV MO D U L E F R A M E IRONRI D G E R A I L DETAIL, MID CLAMP F R O N T Scale: 3 " = 1 ' - 0 " E IRONRIDGE END CLAMPPV MODULE FRAMEIRONRIDGE RAILDETAIL, END CLAMP FRONTScale: 3" = 1'-0"G 120/240 VAC 60HZTO UTILITYGRID (E)(E)LOADSNG (E)200A / 2PNGL2L1(N)30A/2P (E)200A MAIN SERVICE PANEL(E)200A / 2P MAIN BREAKERNGL2L115(E)GROUNDINGELECTRODEINTERCONNECTION NOTES1. ONE OF THE METHODS THAT FOLLOWS SHALL BE USED TO DETERMINE THE RATINGS OFBUSBARS AND PANELBOARDS. (a) THE SUM OF 125 PERCENT OF THE INVERTER(S) OUTPUTCIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THEBUSBAR SHALL NOT EXCEED THE AMPACITY OF THE BUS BAR. (b) WHERE TWO SOURCES,ONE THE UTILITY AND THE OTHER AN INVERTER ARE LOCATED AT OPPOSITE ENDS OF ABUSBAR THAT CONTAINS LOADS, THE SUM OF 125 PERCENT OF THE INVERTER(S) OUTPUTCIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THEBUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR [NEC705.12(D)(3)].3. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9] & [NEC 230.95]4. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING.DISCONNECT NOTES1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH ISOPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THETERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS)2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BELOCKABLE, AND BE A VISIBLE-BREAK SWITCH3. DC CURRENT CONDUCTORS ARE TO REMAIN OUTSIDE OF BUILDING PRIOR TOEITHER A FUSEABLE SOURCE CIRCUIT PV AC DISCONNECTNON- FUSEDLOCKABLE, VISIBLE OPEN30A, 240V, 2-POLEPV BREAKER TO BE LOCATED OPPOSITEEND OF BUSSING FROM MAIN BREAKER = = = = = = = = A C D C L 1 L 2 N G + - + - + - ( 1 ) S T R I N G O F 8 M O D U L E S ( 1 ) S T R I N G O F 1 4 M O D U L E S G + - G + - 3 / 4 " E M T 4 3 2 1 J U N C T I O N B O X = = = = = = = = I N T E G R A T E D R A P I D S H U T D O W N D C D I S C O N N E C T ( 2 2 ) H y u n d a i H i S - S 2 7 0 R G B l a c k ( 2 2 ) P 3 0 0 S o l a r E d g e D C - t o - D C P o w e r O p t i m i z e r S o l a r E d g e S E 5 0 0 0 A - U S I N V E R T E R U L 1 7 4 1 C O M P L I A N T D A T E D R A W I N G B Y P R O J E C T N U M B E R S H E E T N A M E P A G E N U M B E R R E V I S I O N 1 2 2 0 S . 6 3 0 E S T E . 4 3 0 A M E R I C A N F O R K , U T 8 4 0 0 3 8 0 0 - 3 7 7 - 4 4 8 0 W W W . B L U E R A V E N S O L A R . C O M C O N F I D E N T I A L - T H E I N F O R M A T I O N H E R E I N C O N T A I N E D S H A L L N O T B E U S E D F O R T H E B E N E F I T O F A N Y O N E E X C E P T B L U E R A V E N S O L A R N O R S H A L L I T B E D I S C L O S E D I N W H O L E O R I N P A R T T O O T H E R S O U T S I D E R E C I P I E N T S O R G A N I Z A T I O N , E X C E P T I N C O N N E C T I O N W I T H T H E S A L E A N D U S E O F T H E R E S P E C T I V E E Q U I P M E N T , W I T H O U T T H E W R I T T E N P E R M I S S I O N O F B L U E R A V E N S O L A R L L C . P V 5 E L E C . 3 L I N E D I A G . S a s a M a c u r a 2 8 0 7 1 1 4 4 A p r i l 2 7 , 2 0 1 7 A SITE INFORMATION: DC SYSTEM SIZE: David Peck 323 South 3rd East 5.94 Rexburg, Idaho 83440 kW DC PROJECT MANAGER: SCOTT GURNEY 385-498-4401 CONTRACTOR: BLUE RAVEN SOLAR 800.377.4480 AC disconnect to be located within 10' o f U t i l i t y M e t e r . A GROUNDING NOTES1. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH [NEC 690-47] AND[NEC 250-50] THROUGH [NEC 250-60] SHALL BE PROVIDED. PER NEC,GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED ANDBONDED TO AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE,OR INADEQUATE, OR IS ONLY METALLIC WATER PIPING, A SUPPLEMENTALGROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATIONCONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP.2. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG ANDNO GREATER THAN #6 AWG COPPER AND BONDED TO THE EXISTING GROUNDINGELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM.3. PV SYSTEM SHALL BE GROUNDED IN ACCORDANCE TO [NEC 250.21], [NEC TABLE250.122],AND ALL METAL PARTS OR MODULE FRAMES ACCORDING TO [NEC690.46].4. MODULE SOURCE CIRCUITS SHALL BE GROUNDED IN ACCORDANCE TO [NEC690.42].5. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THATTHE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDED CONDUCTORTO ANOTHER MODULE.6. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTIONS POINTSIDENTIFIED IN THE MANUFACTURER'S INSTALLATION INSTRUCTIONS.7. ENCLOSURES SHALL BE PROPERLY PREPARED WITH REMOVAL OF PAINT/FINISHAS APPROPRIATE WHEN GROUNDING EQUIPMENT WITH TERMINATIONGROUNDING LUGS.8. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, ANDGROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR DIRECT BURIAL.9. GROUNDI N G A N D B O N D I N G C O N D U C T O R S S H A L L B E C O P P E R , S O L I D O R STRANDED, A N D B A R E W H E N E X P O S E D . 10. EQUIPM E N T G R O U N D I N G C O N D U C T O R S S H A L L B E S I Z E A C C O R D I N G T O [ N E C 690.45]AN D B E A M I N I M U M O F # 1 0 A W G W H E N N O T E X P O S E D T O D A M A G E ( # 6 A W G SHALL BE US E D W H E N E X P O S E D T O D A M A G E ) . 11. GROUND I N G A N D B O N D I N G C O N D U C T O R S , I F I N S U L A T E D , S H A L L B E C O L O R CODED GRE E N ( O R M A R K E D G R E E N I F # 4 A W G O R L A R G E R ) 12. ALL CON D U I T B E T W E E N T H E U T I L I T Y A C D I S C O N N E C T A N D T H E P O I N T O F CONNECTIO N S H A L L H A V E G R O U N D E D B U S H I N G S A T B O T H E N D S . 13. AC SYST E M G E C S I Z E D A C C O R D I N G T O [ N E C 6 9 0 . 4 7 ] , [ N E C T A B L E 2 5 0 . 6 6 ] , D C SYSTEM GEC S I Z E D A C C O R D I N G T O [ N E C 2 5 0 . 1 6 6 ] , M I N I M U M # 8 A W G W H E N INSULATED, # 6 A W G W H E N E X P O S E D T O D A M A G E . 14. EXPOSE D N O N - C U R R E N T C A R R Y I N G M E T A L P A R T S O F M O D U L E F R A M E S , EQUIPMENTS , A N D C O N D U C T O R E N C L O S U R E S S H A L L B E G R O U N D E D I N ACCORDANC E W I T H 2 5 0 . 1 3 4 O R 2 5 0 . 1 3 6 ( A ) R E G A R D L E S S O F V O L T A G E . WIRING & CO N D U I T N O T E S 1. ALL COND U I T S I Z E S A N D T Y P E S , S H A L L B E L I S T E D F O R I T S P U R P O S E A N D APPROVED F O R T H E S I T E A P P L I C A T I O N S 2. ALL PV CA B L E S A N D H O M E R U N W I R E S B E # 1 0 A W G * U S E - 2 , P V W I R E , O R PROPRIETAR Y S O L A R C A B L I N G S P E C I F I E D B Y M F R , O R E Q U I V A L E N T ; R O U T E D T O SOURCE CIR C U I T C O M B I N E R B O X E S A S R E Q U I R E D 3. ALL COND U C T O R S A N D O C P D S I Z E S A N D T Y P E S S P E C I F I E D A C C O R D I N G T O [ N E C 690.8] FOR M U L T I P L E C O N D U C T O R S 4. ALL PV DC C O N D U C T O R S I N C O N D U I T E X P O S E D T O S U N L I G H T S H A L L B E DERATED AC C O R D I N G T O [ N E C T A B L E 3 1 0 . 1 5 ( B ) ( 2 ) ( a ) , N E C T A B L E 3 1 0 . 1 5 ( B ) ( 3 ) ( a ) , & NEC 310.15 ( B ) ( 3 ) ( c ) ] 5 . E X P O S E D R O O F P V D C C O N D U C T O R S S H A L L B E U S E - 2 , 9 0 ° C R A T E D , W E T A N D U V R E S I S T A N T , A N D U L L I S T E D R A T E D F O R 6 0 0 V , U V R A T E D S P I R A L W R A P S H A L L B E U S E D T O P R O T E C T W I R E F R O M S H A R P E D G E S 6 . P H A S E A N D N E U T R A L C O N D U C T O R S S H A L L B E D U A L R A T E D T H H N / T H W N - 2 I N S U L A T E D , 9 0 ° C R A T E D , W E T A N D U V R E S I S T A N T , R A T E D F O R 6 0 0 V 7 . 4 - W I R E D E L T A C O N N E C T E D S Y S T E M S H A V E T H E P H A S E W I T H T H E H I G H E R V O L T A G E T O G R O U N D M A R K E D O R A N G E O R I D E N T I F I E D B Y O T H E R E F F E C T I V E M E A N S 8 . A L L S O U R C E C I R C U I T S S H A L L H A V E I N D I V I D U A L S O U R C E C I R C U I T P R O T E C T I O N 9 . V O L T A G E D R O P L I M I T E D T O 2 % F O R D C C I R C U I T S A N D 1 % F O R A C C I R C U I T S 1 0 . N E G A T I V E G R O U N D E D S Y S T E M S D C C O N D U C T O R S S H A L L B E C O L O R C O D E D A S F O L L O W S : D C P O S I T I V E - R E D ( O R M A R K E D R E D ) , D C N E G A T I V E - G R E Y ( O R M A R K E D G R E Y ) 1 1 . P O S I T I V E G R O U N D E D S Y S T E M S D C C O N D U C T O R S C O L O R C O D E D : D C P O S I T I V E - G R E Y ( O R M A R K E D G R E Y ) , D C N E G A T I V E - B L A C K ( O R M A R K E D B L A C K ) 1 2 . A C C O N D U C T O R S > 4 A W G C O L O R C O D E D O R M A R K E D : P H A S E A O R L 1 - B L A C K , P H A S E B O R L 2 - R E D , P H A S E C O R L 3 - B L U E , N E U T R A L - W H I T E / G R A Y * U S E - 2 I S N O T I N D O O R R A T E D B U T P V C A B L E I S R A T E D T H W N / T H W N - 2 A N D M A Y B E U S E D I N S I D E * * U S E - 2 I S A V A I L A B L E A S U V W H I T E 1 3 . I F C O N D U I T D E T E R M I N E D T O B E R A N T H R O U G H A T T I C I N F I E L D T H E N C O N D U I T W I L L B E E I T H E R E M T , F M C , O R M C C A B L E C O M P L Y I N G W I T H N E C 6 9 0 . 3 1 , N E C 2 5 0 . 1 1 8 ( 1 0 ) A N D D I S C O N N E C T I N G M E A N S S H A L L C O M P L Y W I T H 6 9 0 . 1 3 ( B ) A N D ( C ) A N D 6 9 0 . 1 5 ( A ) A N D ( B ) . C O N D U I T R A N T H R O U G H A T T I C W I L L B E A T L E A S T 1 0 " B E L O W R O O F S U R F A C E . 1 2 2 0 S . 6 3 0 E S T E . 4 3 0 A M E R I C A N F O R K , U T 8 4 0 0 3 8 0 0 - 3 7 7 - 4 4 8 0 W W W . B L U E R A V E N S O L A R . C O M C O N F I D E N T I A L - T H E I N F O R M A T I O N H E R E I N C O N T A I N E D S H A L L N O T B E U S E D F O R T H E B E N E F I T O F A N Y O N E E X C E P T B L U E R A V E N S O L A R N O R S H A L L I T B E D I S C L O S E D I N W H O L E O R I N P A R T T O O T H E R S O U T S I D E R E C I P I E N T S O R G A N I Z A T I O N , E X C E P T I N C O N N E C T I O N W I T H T H E S A L E A N D U S E O F T H E R E S P E C T I V E E Q U I P M E N T , W I T H O U T T H E W R I T T E N P E R M I S S I O N O F B L U E R A V E N S O L A R L L C . PROJECT MANAGER: SCOTT GURNEY 385-498-4401 CONTRACTOR: BLUE RAVEN SOLAR 800.377.4480 D A T E D R A W I N G B Y P R O J E C T N U M B E R S H E E T N A M E P A G E N U M B E R R E V I S I O N P V 6 E L E C . C A L C S . S a s a M a c u r a 2 8 0 7 1 1 4 4 A p r i l 2 7 , 2 0 1 7 A SITE INFORMATION: DC SYSTEM SIZE: David Peck 323 South 3rd East 5.94 Rexburg, Idaho 83440 kW DC J U N C T I O N B O X O R C O M B I N E R B O X M A I N S E R V I C E P A N E L A C D I S C O N N E C T E X I S T I N G S U B P A N E L ( I F W H E R E P O I N T O F I N T E R C O N N E C T I O N I S M A D E ) N E W P V S U B P A N E L ( I F 2 I N V E R T E R S A R E U S E D A N D C O M B I N I N G P V S O U R C E C I R C U I T S I N N E W L O A D C E N T E R ) A C D C I N V E R T E R ( S ) I N T E G R A T E D D C D I S C O N N E C T 2 2 2 2 2 3 1 4 4 5 5 6 8 8 8 8 1 1 1 1 2 ELECTRIC SHOCK HAZARDDO NOT TOUCH TERMINALSTERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING ELECTRIC SHOCK HAZARD.THE DC CONDUCTORS OF THISPHOTOVOLTAIC SYSTEM ARE UNGROUNDEDAND MAY BE ENERGIZED.WARNINGLABEL 1AT EACH JUNCTION BOX, COMBINER BOX,DISCONNECT AND DEVICE WHERE ENERGIZE D UNGROUNDED CONDUCTORS MAY BE EXPOS E D DURING SERVICE [NEC. 690.35(F)]LABEL 2AT EACH DISCONNECTING MEANS FORPHOTOVOLTAIC EQUIPMENT [NEC 690.17(E)]LABEL 3AT EACH DC DISCONNECTING MEANS [NEC 6 9 0 . 5 3 ] MAX. POWER POINT CURRENT (IMP) =MAX. POWER POINT VOLTAGE (VMP) =MAX. SYSTEM VOLTAGE (VOC) =SHORT-CIRCUIT CURRENT (ISC) =NOMINAL AC OPERATING VOLTAGE =PHOTOVOLTAICAC DISCONNECT LABEL 4AT POINT OF INTERCONNECTION, MARKED A T DISCONNECTING MEANS [NEC 690.54]DUEL POWER SOURCES.SECOND SOURCE IS PV SYSTEM WARNING LABEL 5AT POINT OF INTERCONNECTION; LABEL,SUC H A S LABEL 5 OR LABEL 6 MUST IDENTIFY PHOTOV O L T A I C SYSTEM[NEC 705.12(D)(3)]MAX. AC OPERATING CURRENT =PHOTOVOLTAICDC DISCONNECT LABEL 6AT EACH DC DISCONNECTING MEANS[NEC 690.13(B)] I N T E R A C T I V E P H O T O V O L T A I C S Y S T E M C O N N E C T E D P H O T O V O L T A I C S Y S T E M D I S C O N N E C T L O C A T E D A T S I D E O F H O U S E LABEL 8AT EACH AC DISCONNECTINGMEANS[NEC 690.13(B)]PHOTOVOLTAICAC DISCONNECTLABEL 9AT EXPOSED RACEWAYS, CABLETRAYS, AND OTHER WIRING METHOD S ; SPACED AT MAXIMUM 10FT SECTIONOR WHERE SEPARATED BYENCLOSURES, WALLS, PARTITIONS,CEILINGS, OR FLOORS [NEC690.31(G)(3)] I N V E R T E R O U T P U T C O N N E C T I O N D O N O T R E L O C A T E T H I S O V E R C U R R E N T D E V I C E W A R N I N G L A B E L 1 0 P L A C E D A D J A C E N T T O T H E B A C K - F E D B R E A K E R F R O M T H E I N V E R T E R I F T I E I N C O N S I S T S O F L O A D S I D E C O N N E C T I O N T O B U S B A R . [ N E C 7 0 5 . 1 2 ( D ) ( 2 ) ( 3 ) ( b ) ] LABELING NOTES:1.LABELING REQUIREMENTS BASED ON THE 2014 NATIONAL ELECTRIC CODE,INTERNATIONAL FIRE CODE 605.11, OSHA STANDARD 19010.145, ANSI Z535.2.MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVINGJURISDICTION.3.LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENTINVOLVED.4.LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON REDBACKGROUND; REFLECTIVE, AND PERMANENTLY AFFIXED [IFC 605.11.1.1] D I R E C T O R Y P L A Q U E P E R M A N E N T P L A Q U E O R D I R E C T O R Y P R O V I D I N G T H E L O C A T I O N O F T H E S E R V I C E D I S C O N N E C T I N G M E A N S A N D T H E P H O T O V O L T A I C S Y S T E M D I S C O N N E C T I N G M E A N S I F N O T I N T H E S A M E L O C A T I O N [ N E C 6 9 0 . 5 6 ( B ) ] WARNING: PHOTOVOLTAICPOWER SOURCE P H O T O V O L T A I C S Y S T E M E Q U I P P E D W I T H R A P I D S H U T D O W N R A P I D S H U T D O W N D I S C O N N E C T L A B E L 1 2 S I G N L O C A T E D A T R A P I D S H U T D O W N D I S C O N N E C T C O N T R O L L E R . L A B E L 1 1 S I G N L O C A T E D A T S E R V I C E E Q U I P M E N T [ N E C 6 9 0 . 5 6 ( C ) ] D R A W I N G B Y D A T E P R O J E C T N U M B E R S H E E T N A M E P A G E N U M B E R R E V I S I O N 1 2 2 0 S . 6 3 0 E S T E . 4 3 0 A M E R I C A N F O R K , U T 8 4 0 0 3 8 0 0 - 3 7 7 - 4 4 8 0 W W W . B L U E R A V E N S O L A R . C O M C O N F I D E N T I A L - T H E I N F O R M A T I O N H E R E I N C O N T A I N E D S H A L L N O T B E U S E D F O R T H E B E N E F I T O F A N Y O N E E X C E P T B L U E R A V E N S O L A R N O R S H A L L I T B E D I S C L O S E D I N W H O L E O R I N P A R T T O O T H E R S O U T S I D E R E C I P I E N T S O R G A N I Z A T I O N , E X C E P T I N C O N N E C T I O N W I T H T H E S A L E A N D U S E O F T H E R E S P E C T I V E E Q U I P M E N T , W I T H O U T T H E W R I T T E N P E R M I S S I O N O F B L U E R A V E N S O L A R L L C . P V 8 L A B E L S S a s a M a c u r a 2 8 0 7 1 1 4 4 A p r i l 2 7 , 2 0 1 7 A SITE INFORMATION: DC SYSTEM SIZE: David Peck 323 South 3rd East 5.94 Rexburg, Idaho 83440 kW DC PROJECT MANAGER: SCOTT GURNEY 385-498-4401 CONTRACTOR: BLUE RAVEN SOLAR 800.377.4480