HomeMy WebLinkAboutPLANS - 17-00362 - DL Evans Bank - Tenant Finish0 I d- 4 WOOD STUD 16" O.C. ) U N D BATT SULATION :ONFERENCE ONLY) VE LAYER 5/8" (PSUM WALL )ARD EACH SIDE. NOTE: ALL NEW INTERIOR FRAMING TO EXTEND FULL HEIGHT TO BOTTOM OF CEILING UNLESS NOTED OTHERWISE. 1. new wall type SCALE: 1 " = 1'-0" 3" INSULATION BLANKET (CONFERENCE ONLY) EXISTING SUSPENDED CEILING EXISTING� ACT BRACE 4'-0" OC EACH WAY @ 45• EXISTING CEILING TILE J MOLDING 1/2" FOAM TAPE WALL TYPE PER - PLAN 2. wall bracing SCALE: 1-1/2" = 1'-0" kLL TYPE PER PLAN ALANT ALL SIDES )LLOW METAL FRAME TAL FRAME ANCHORS ,OR PER SCHEDULE 3. typical door frame a head/jamb SCALE: 3" = 1'-0" WALL TYPE AS SCHEDULED SEALANT EACH SIDE HOLLOW METAL FRAME HOLLOW METAL STOP GLAZING AS SCHEDULED 4. hollow metal window a head/sill SCALE: 3" = 1'-0" 8.5" 5. tactile signage SCALE: 3" = 1'-0" ACCESSIBLE SYMBOL WHERE OCCURS COMPLY WITH ICC/ANSI 703.4 PICTOGRAM CHARACTER WHERE OCCURS COMPLY WITH ICC/ANSI 703.6 CHARACTERS AS SPECIFIED COMPLY WITH ICC/ANSI 703.2 BRAILLE CHARACTERS COMPLY WITH ICC/ANSI 703.5 SIGNAGE SCHEDULE ROOM NO. SIGN TEXT 110 WOMEN 109 MEN 1. NEW TOILET; LOCATE PER ELEVATIONS 00 2. NEW SINK; LOCATE PER PL2 ANSI STANDARDS. b. teller line SCALE: 1/4" = 1'-0" :; 36" IM plan 23 W. 3'-0" 2'-2" J. W. 10 0 1. NEW TOILET; LOCATE PER ELEVATIONS 00 2. NEW SINK; LOCATE PER PL2 ANSI STANDARDS. 3. NEW ADA GRAB BARS PER ELEVATIONS I co ryLd PL2 -_ WRIA � � W 7 -7-7--REF.II N Z (� II PL3 I w X0 w 0 X� < �F N II (III I I I IIIIIII I Cn DW I �� z 0UJ D' IIIIII 1 UII� II - 0 < �� � I II 2'-l" 2'-1 S-0" CLEAR 3'- 6 1" ^ an 1" 1" = CD a 00 0< i k. breakroom ^ o �0 I J O N MJ J It 30'CLR. R62 i. restroom typ. SCALE: 1/4" = 1'-0" :; 36" IM plan •\ W. 3'-0" 2'-2" J. W. 10 1. NEW TOILET; LOCATE PER ELEVATIONS 11 2. NEW SINK; LOCATE PER PL2 ANSI STANDARDS. 3. NEW ADA GRAB BARS PER ELEVATIONS & ANSI STANDARDS. -_ WRIA �- 7 -7-7--REF.II 18" J� r C N furniture/fi SCALE: 1/8" = 1'-0" TRUE GE 31 T 31 R 31 Wish plan 0 keynotes 1. RESTROOMS TO RECEIVE PL2 WAINSCOT TO 60" A.F.F. WITH STAINLESS STEEL TOP EDGE TRIM ON ALL WALLS. PAINT P1 ABOVE. 2.APPLY FRP TO WALLS AROUND MOP SINK TO EXTENT SHOWN. 3. TRANSITION STRIP TR1. 4. FURNITURE PROVIDED BY OWNER. FOR COORDINATION ONLY. 5. COPIER EQUIPMENT PROVIDED AND INSTALLED BY OWNER. 6. VAULT EQUIPMENT PROVIDED AND INSTALLED BY OWNER. 7. REFRIGERATOR, CONTRACTOR PROVIDED AND INSTALLED. GE MODEL GNE29GGKWW. 8. ADA HEIGHT DISHWASHER, CONTRACTOR PROVIDED AND INSTALLED. GE MODEL GLDA690FWW. 9. EXISTING COLUMN PAINT P1. 10. TV, CONTRACTOR PROVIDED AND INSTALLED. MODEL TBD BY OWNER. 11. I.T. RACK BY OTHERS. 12. PROVIDE TACTILE RESTROOM SIGNAGE PER ANSI REQUIREMENTS. SEE 5/a 1.0. c. teller line - behind SCALE: 1/4" = 1'-0" j. restroom typ. SCALE: 1/4" = 1'-0" 1"2'-1" plan 2'-1" W. 3'-0" 2'-2" J. W. 10 1. NEW TOILET; LOCATE PER ELEVATIONS & ANSI STANDARDS. 2. NEW SINK; LOCATE PER PL2 ANSI STANDARDS. 3. NEW ADA GRAB BARS PER ELEVATIONS & ANSI STANDARDS. -_ �- 7 -7-7--REF.II N I/ vv vv II PL3 I r�l�lll� 1 O PL2 �F N II (III I I I IIIIIII I 0 DW I -__- _ --- --- 11 IIIIII 1 UII� II - I II 2'-l" 2'-1 S-0" CLEAR 3'- 6 1" an 1" 1" 1"OVER- FILLER PANEL PANEL HANG k. breakroom SCALE: 1/4" = 1'-0" E N rcp/power plan SCALE: 1/8" = 1'-0" TRUE keynotes: 1. EXISTING ELECTRICAL PANEL. 2. PROVIDE POWER AND DATA TO ATM. 3. PROVIDE POWER TO NIGHT DROP. 4. PROVIDE POWER AND DATA TO COPIER. 5. PROVIDE POWER AND DATA TO TV. 6. PROVIDE POWER AND DATA TO I.T. RACK. 7. REPLACE ALL SWITCHES/SWITCH PLATES AND OUTLETS/COVERPLATES IN SPACE WITH WHITE PLATES AND APPLIANCES. 8. NEW LOCATION OF MOVED HVAC GRILLE. PAINT TO MATCH NEW CEILING COLOR. 9. ROUTE NEW POWER, PHONE, AND DATA FROM EXISTING WALL THROUGH TELLER LINE. WALL CONNECTION CONTRACTOR INSTALLED; CABLING INSTALLATION BY OWNER. 10. NEW VANITY LIGHT FIXTURE, 24" LED TERON LIGHTING CPR24-L41.0-100-277V-TE700-SM-35K. SEE ELEVATION FOR MOUNTING HEIGHT, CENTER ABOVE VANITY AND MIRROR. 11. PROVIDE POWER AND DATA TO COUNTERTOP CARD ISSUE MACHINE. 12. NEW RECESSED 2X4' LIGHT FIXTURE, METALUX 24CZ-LD4-55-S-UNV-L835-CD-1-U. (24 PIECES) 13. NEW SURFACE MOUNT 4' LED LIGHT FIXTURE, METALUX 4-SNLED-LD4-54HL-LW-UNV-EL14W-L835-CD1-U-AYC. (2 PIECES) 14. PROVIDE POWER AND DATA AT DESK LOCATIONS. USE SURFACE MOUNT CONDUIT IF NEEDED, PAINTED TO MATCH WALL. 15. ALL EXISTING HVAC REGISTERS TO BE PAINTED TO MATCH NEW CEILING COLOR. 16. PROVIDE NEW VENT FAN THROUGH ROOF. PATCH AND REPAIR WITH WEATHERPROOF BOOT. 17. NEW WALL SWITCH LOCATION. 18. NEW RETURN AIR GRILLE. ; JANITOR 111 in I O 0 NIGHT DROP N floorPlan- SCALE: 1/8" = 1'-0" TRUE IVB v TELLER LINE 0 keynotes 1. TELLER LINE; OWNER PROVIDED, CONTRACTOR INSTALLED. 2. PARTIAL HEIGHT TELLER LINE WALL EXTENSION TO MATCH EXISTING FROM OWNER; SEE ELEVATIONS FOR HEIGHTS. 3. 3070 SOLID CORE WOOD DOOR STAINED ST1, PASSAGE HARDWARE. 4. 3670 SOLID CORE SLAB WITH STAINLESS STEEL SKIN. 5. 3070 SOLID CORE, SINGLE LITE WOOD DOOR STAINED ST1 WITH CLEAR, TEMPERED GLAZING, PASSAGE HARDWARE. 6. 3070 SOLID CORE WOOD DOOR STAINED ST1, STOREROOM LOCKSET HARDWARE. 7. 3070 HOLLOW METAL DOOR PAINTED P1. PRIVACY LOCKSET HARDWARE. 8. NEW MOP SINK. 9. NEW WATER HEATER ABOVE MOP SINK. 10. NIGHT DROP BY OWNER; CONTRACTOR TO COORDINATE INSTALLATION IN WINDOW OPENING TO COMPLY WITH ADA REQUIREMENTS. PROVIDE SECURE FRAMING AROUND EQUIPMENT AND FINISH EXTERIOR WITH METAL TO FINISH AROUND EQUIPMENT. 11. FINISH EXTERIOR WITH METAL TO MATCH ADJACENT NIGHT DROP WINDOW. 12. ATM BY OWNER ON NEW CONCRETE PAD BY CONTRACTOR. ATM INSTALLATION TO COMPLY WITH ADA REQUIREMENTS; SEE PRODUCT SPECIFICATION FOR MORE INFORMATION. 13. CHECK WRITING STAND, SEE ELEVATIONS AND DETAILS. 14. MAY NOT NEED TO FURR OUT WALL FOR NEW PLUMBING. VERIFY ON-SITE. 15. MAY NEED TO FURR OUT WALL FOR PLUMBING. VERIFY ON-SITE. 16. NEW ADA COMPLIANT THRESHOLD. PATCH AND/OR RAMP EXTERIOR CONCRETE AS NEEDED TO PROVIDE A SMOOTH, UNIFORM <1:12 SLOPE TO THRESHOLD ALONG LENGTH OF DOOR OPENING. 17. PAINT SIDING AND TRIM ABOVE ENTRY P3. 18. VAULT DAY GATE PROVIDED BY OTHERS. 19. ADA DRINKING FOUNTAIN/BOTTLE FILLER, ELKAY EZH2O OR SIMILAR. 20.3070 HOLLOW METAL DOOR PAINTED P1, PASSAGE HARDWARE. co I N \ V// \\V V// PL3 0 I PL1 0 // \\ // \ OPEN AREA FOR _ EQUIPMENT N I / 1' d. teller line - behind e. copy area SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" O 0 i� 4'-0" T-1 TEMPERED 1/4" CLEAR GLASS I. conference glazing SCALE: 1/4" = 1'-0" N demo lan/rc SCALE: 1/8 TRUE 0 keynotes 1. REMOVE EXISTING FLOOR COVERING, UNDER FLOOR CONDUIT, AND WALL BASE THROUGHOUT. PREP FOR NEW FLOOR FINISH AND WALL BASE. 2. REMOVE EXISTING RACK SYSTEM. PREP WALL FOR NEW PAINT. 3. REMOVE THRESHOLD AND PREPARE SURFACE FOR NEW ADA COMPLIANT TRANSITION. 4. REMOVE EXISTING TRANSITION STRIP. PREP FOR NEW FLOORING. 5. REMOVE EXISTING WALL AND DOOR. SEE FLOOR PLAN FOR NEW WALL LOCATIONS. 6. REMOVE EXISTING DOOR. REVERSE HINGE SIDE. 7. REMOVE WOOD BRACING. PREP WALL FOR NEW FINISH. 8. REMOVE EXISTING LAVATORY, WATER HEATER, MIRROR, AND PAPER TOWEL HOLDER. PREP WALL FOR NEW FINISHES. 9. REMOVE EXISTING TOILET AND TISSUE HOLDER. PREP WALL FOR NEW FINISHES. SEE FLOOR PLAN FOR NEW TOILET LOCATIONS. 10. REMOVE EXISTING GRAB BARS. PREP WALL FOR NEW FINISHES. 11. RELOCATE EXISTING WALL SWITCH. SEE RCP + POWER PLAN. 12. REMOVE EXISTING SHELVING. SEE FLOOR PLAN FOR NEW DATA LOCATION. 13. KEEP EXISTING CEILING GRID. REMOVE ALL LIGHTING AND REPLACE ALL TILES, SEE FINISH SCHEDULE FOR NEW TILE ACT AND RCP + POWER PLAN FOR NEW LIGHTING LOCATIONS AND TYPES. 14. CLEAN AND PREP CONCRETE FOR NEW FLOOR COVERING. 15. REMOVE EXISTING WINDOW AND PREPARE FOR NEW NIGHT DROP AND ATM LOCATIONS. SEE FLOOR PLAN FOR MORE INFORMATION. 16. THOROUGHLY CLEAN CMU WALLS, SIDEWALK, AND SOFFIT AND FASCIA ABOVE. 17. EXISTING COLUMN TO REMAIN. REMOVE ATTACHED EQUIPMENT AND PREP FOR NEW PAINT. 18. EXISTING FIRE SPRINKLER LOCATIONS IN CEILING TO REMAIN. ADJUST IF NECESSARY TO FIT NEW ROOM LAYOUT. 19. EXISTING HVAC GRILLE TO BE RELOCATED; SEE RCP. 20. REMOVE PORTION OF SUSPENDED CEILING AND PREP FOR NEW CEILING. 21. EXISTING ELECTRICAL PANEL TO REMAIN. 1 V 2'-6" '°11&12'- 1„ 2,-1>,?0„ P LA M <D VAULT , PL3 PANEL (EQUIP. PL2 BRACKET PL2 _ _7 \ I I'/ \`I �/ N PL3 0 BRACKET 1 N _ - o_ 0 1 I N \ / N --- 3'-6 3'-0" 3'-0" 2'-6" -2'2'-0" 2'-0" A 014 1" 1"Of or01 2" f. vault a storage SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" a plan FRAME PL1 INLAY PL3 3 /4" SHORT UNIT TALL UNIT 3/ 4 % 111*11 \" % 2'-10 1/2"" 2'-10 1/2"" 3'-0 3'-0 b elevation c 3'-0" 3'-0"1 /4" GLASS, SMOOTH EDGES 1/4" DIVIDERS PL2 DIVIDERS, PL1 MAX 3/8" THICK 0 T N /4" rApp V_'A I BWA � I SHORT UNIT TALL UNIT m. check writing station 2 1-0" 2'-2" 2'-2" 2'-2" 2'-2" 2» L. L. L. IT=- / 2'-0" 2'-2" -2 2'-2" 2'-2" 2" h. storage SCALE: 1/4" = 1'-0" c sectio 2'-0" INLAY PL3 7 1/ PL1 PL1 $" N BLACK MELAMINE ON PLYWOOD d SUBSTRATE PL1 I M NOTE: CHECK WRITING STAND MILLWORK TO BE BUILT AS TWO FREESTANDING, MOBILE UNITS. L I I / L------- -I / WOMENS �T I 110 I I I i --- 611.0 i TYP. / Oil TYP. Ct 00 I � I I /-�-J `MENS-- \ -- Irt79 ----r- I I I I 1 � 1.0 i / 11� � 00 3 a. enlarcled plan SCALE: 1/4" = 1'-0" 0 keynotes 1. NEW TOILET; LOCATE PER ELEVATIONS & ANSI STANDARDS. 2. NEW SINK; LOCATE PER ELEVATIONS & ANSI STANDARDS. 3. NEW ADA GRAB BARS PER ELEVATIONS & ANSI STANDARDS. b elevation c 3'-0" 3'-0"1 /4" GLASS, SMOOTH EDGES 1/4" DIVIDERS PL2 DIVIDERS, PL1 MAX 3/8" THICK 0 T N /4" rApp V_'A I BWA � I SHORT UNIT TALL UNIT m. check writing station 2 1-0" 2'-2" 2'-2" 2'-2" 2'-2" 2» L. L. L. IT=- / 2'-0" 2'-2" -2 2'-2" 2'-2" 2" h. storage SCALE: 1/4" = 1'-0" c sectio 2'-0" INLAY PL3 7 1/ PL1 PL1 $" N BLACK MELAMINE ON PLYWOOD d SUBSTRATE PL1 I M NOTE: CHECK WRITING STAND MILLWORK TO BE BUILT AS TWO FREESTANDING, MOBILE UNITS. L I I / L------- -I / WOMENS �T I 110 I I I i --- 611.0 i TYP. / Oil TYP. Ct 00 I � I I /-�-J `MENS-- \ -- Irt79 ----r- I I I I 1 � 1.0 i / 11� � 00 3 a. enlarcled plan SCALE: 1/4" = 1'-0" 0 keynotes 1. NEW TOILET; LOCATE PER ELEVATIONS & ANSI STANDARDS. 2. NEW SINK; LOCATE PER ELEVATIONS & ANSI STANDARDS. 3. NEW ADA GRAB BARS PER ELEVATIONS & ANSI STANDARDS. � I SHORT UNIT TALL UNIT m. check writing station 2 1-0" 2'-2" 2'-2" 2'-2" 2'-2" 2» L. L. L. IT=- / 2'-0" 2'-2" -2 2'-2" 2'-2" 2" h. storage SCALE: 1/4" = 1'-0" c sectio 2'-0" INLAY PL3 7 1/ PL1 PL1 $" N BLACK MELAMINE ON PLYWOOD d SUBSTRATE PL1 I M NOTE: CHECK WRITING STAND MILLWORK TO BE BUILT AS TWO FREESTANDING, MOBILE UNITS. L I I / L------- -I / WOMENS �T I 110 I I I i --- 611.0 i TYP. / Oil TYP. Ct 00 I � I I /-�-J `MENS-- \ -- Irt79 ----r- I I I I 1 � 1.0 i / 11� � 00 3 a. enlarcled plan SCALE: 1/4" = 1'-0" 0 keynotes 1. NEW TOILET; LOCATE PER ELEVATIONS & ANSI STANDARDS. 2. NEW SINK; LOCATE PER ELEVATIONS & ANSI STANDARDS. 3. NEW ADA GRAB BARS PER ELEVATIONS & ANSI STANDARDS. 2" h. storage SCALE: 1/4" = 1'-0" c sectio 2'-0" INLAY PL3 7 1/ PL1 PL1 $" N BLACK MELAMINE ON PLYWOOD d SUBSTRATE PL1 I M NOTE: CHECK WRITING STAND MILLWORK TO BE BUILT AS TWO FREESTANDING, MOBILE UNITS. L I I / L------- -I / WOMENS �T I 110 I I I i --- 611.0 i TYP. / Oil TYP. Ct 00 I � I I /-�-J `MENS-- \ -- Irt79 ----r- I I I I 1 � 1.0 i / 11� � 00 3 a. enlarcled plan SCALE: 1/4" = 1'-0" 0 keynotes 1. NEW TOILET; LOCATE PER ELEVATIONS & ANSI STANDARDS. 2. NEW SINK; LOCATE PER ELEVATIONS & ANSI STANDARDS. 3. NEW ADA GRAB BARS PER ELEVATIONS & ANSI STANDARDS. ROOM FINISH LEGEND CEILING GYP: GYPSUM WALL BOARD, PAINTED P2 ACT: ACOUSTICAL LAY -IN CEILING, ARMSTRONG ULTIMA 2'X4' BEVELED TEGULAR ON EXISTING GRID PAINT/STAIN P1: PAINT FIELD, SHERWIN WILLIAMS SW6169/21 1-C1 SEDATE GRAY, EGGSHELL SHEEN P2: PAINT CEILING, SHERWIN WILLIAMS SW7009/254-C2 PEARLY WHITE, FLAT SHEEN P3: PAINT EXTERIOR, SHERWIN WILLIAMS SW7048/245-C7 URBANE BRONZE, SATIN SHEEN FLOOR CPT: CARPET TILE, TANDUS CENTIVA RESPONSE #04704, 24"x24", BACKING: FLEXAIRE CUSHION MODULAR, COLOR: CARAMEL #02833, QUARTER TURN INSTALLATION SC: SEALED CONCRETE SV: SHEET VINYL, ARMSTRONG REJUVENATIONS STONERUN 6' WIDE, COLOR: SIDECAR 34350 SUBWAY; HEAT WELD COLOR W0880 NATURAL GRAY LIGHT BASE RB1: RUBBER BASE, JOHNSONITE TRADITIONAL PROFILE, 4"H, 63 BURNT UMBER RB2: RUBBER BASE, JOHNSONITE TRADITIONAL PROFILE, 6"H, 63 BURNT UMBER CABINETRY PL1: PLASTIC LAMINATE, WILSONART 7122-07 EMPIRE MAHOGANY. COLOR MATCH 3MM EDGE BANDING PL2: PLASTIC LAMINATE, FORMICA 5880-58 EARTHEN WARP. COLOR MATCH 3MM EDGE BANDING COUNTERTOPS PL3: PLASTIC LAMINATE, PIONITE AT440 CONNECTED CUBES MISCELLANEOUS FRP: FIBER REINFORCED PLASTIC WAINSCOT 60" A.F.F., SMOOTH WHITE ST1: WOOD STAIN, CUSTOM TO MATCH PL1 TR1: TRANSITION STRIP, JOHNSONITE CARPET TO SHEET VINYL REDUCER STRIP, COLOR TO MATCH R131 summaproject y PROJECT IS A TENANT IMPROVEMENT FOR A BANK BRANCH TO BE LOCATED IN AN EXISTING VACANT COMMERCIAL SPACE. EXISTING FLOOR AREA WILL REMAIN - NO ENLARGEMENT. OCCUPANCY: B CONSTRUCTION TYPE: II -B FLOOR AREA: 2,400 SF OCCUPANT LOAD: 24 PROJECT SCOPE INCLUDES: • REMOVAL OF EXISTING NON-BEARING WALLS AND CONSTRUCTION OF NEW NON-BEARING WALLS. • REMOVAL OF EXISTING RESTROOM AND CONSTRUCTION OF TWO NEW RESTROOMS TO COMPLY WITH CURRENT ADA/ANSI REQUIREMENTS AND REGULATIONS. • ALL EXISTING HVAC SYSTEMS SHALL REMAIN. • ALL EXISTING ELECTRICAL DISTRIBUTION PANEL FIXTURES SHALL REMAIN. APPLICABLE CODES: 2012 INTERNATIONAL BUILDING CODE 2012 INTERNATIONAL MECHANICAL CODE 2012 INTERNATIONAL FUEL GAS CODE 2012 INTERNATIONAL ENERGY CONSERVATION CODE 2009 IDAHO STATE PLUMBING CODE 2014 NATIONAL ELECTRICAL CODE 2012 NATIONAL FIRE CODE 2009 ICC/ANSI A117.1 ACCESSIBLE BUILDING STANDARDS eneral notes: c A. CONTRACTOR TO VERIFY ALL DIMENSIONS IN FIELD; NOTIFY ARCHITECT IF DISCREPANCIES ARE FOUND. B. UNLESS NOTED OTHERWISE ALL INTERIOR PARTITIONS ARE DIMENSIONED TO FACE OF STUD. C. CONTRACTOR TO VERIFY THAT EXISTING FIRE DETECTION AND ALARM SYSTEMS AND EQUIPMENT ADHERE TO FIRE CODE. D. EXTERIOR LIGHTED SIGNAGE PROVIDED BY OTHERS. N O O U co 12 Vi O U � L U�� o� U °' 3 3 QLO O M O co N o CO /� o W M CV This document is the property of e r s t a d ARCHITECTS and is protected by U.S. and International laws. Use, r e p r o d u c t i o n o r modification of this document without first obtaining the written permission of erstad ARCHITECTS is prohibited. This document may not be used in any unauthorized m a n n e r. (02 0 1 7 t+ N O co 00 > J_ - Cd Cd CO Cd C > LO x /� N N revision: project: 170404 date: 06/29/17 drawn: sb/cb checked: ti permit set plans a1.0 PL3: PLASTIC LAMINATE, PIONITE AT440 CONNECTED CUBES MISCELLANEOUS FRP: FIBER REINFORCED PLASTIC WAINSCOT 60" A.F.F., SMOOTH WHITE ST1: WOOD STAIN, CUSTOM TO MATCH PL1 TR1: TRANSITION STRIP, JOHNSONITE CARPET TO SHEET VINYL REDUCER STRIP, COLOR TO MATCH R131 summaproject y PROJECT IS A TENANT IMPROVEMENT FOR A BANK BRANCH TO BE LOCATED IN AN EXISTING VACANT COMMERCIAL SPACE. EXISTING FLOOR AREA WILL REMAIN - NO ENLARGEMENT. OCCUPANCY: B CONSTRUCTION TYPE: II -B FLOOR AREA: 2,400 SF OCCUPANT LOAD: 24 PROJECT SCOPE INCLUDES: • REMOVAL OF EXISTING NON-BEARING WALLS AND CONSTRUCTION OF NEW NON-BEARING WALLS. • REMOVAL OF EXISTING RESTROOM AND CONSTRUCTION OF TWO NEW RESTROOMS TO COMPLY WITH CURRENT ADA/ANSI REQUIREMENTS AND REGULATIONS. • ALL EXISTING HVAC SYSTEMS SHALL REMAIN. • ALL EXISTING ELECTRICAL DISTRIBUTION PANEL FIXTURES SHALL REMAIN. APPLICABLE CODES: 2012 INTERNATIONAL BUILDING CODE 2012 INTERNATIONAL MECHANICAL CODE 2012 INTERNATIONAL FUEL GAS CODE 2012 INTERNATIONAL ENERGY CONSERVATION CODE 2009 IDAHO STATE PLUMBING CODE 2014 NATIONAL ELECTRICAL CODE 2012 NATIONAL FIRE CODE 2009 ICC/ANSI A117.1 ACCESSIBLE BUILDING STANDARDS eneral notes: c A. CONTRACTOR TO VERIFY ALL DIMENSIONS IN FIELD; NOTIFY ARCHITECT IF DISCREPANCIES ARE FOUND. B. UNLESS NOTED OTHERWISE ALL INTERIOR PARTITIONS ARE DIMENSIONED TO FACE OF STUD. C. CONTRACTOR TO VERIFY THAT EXISTING FIRE DETECTION AND ALARM SYSTEMS AND EQUIPMENT ADHERE TO FIRE CODE. D. EXTERIOR LIGHTED SIGNAGE PROVIDED BY OTHERS. N O O U co 12 Vi O U � L U�� o� U °' 3 3 QLO O M O co N o CO /� o W M CV This document is the property of e r s t a d ARCHITECTS and is protected by U.S. and International laws. Use, r e p r o d u c t i o n o r modification of this document without first obtaining the written permission of erstad ARCHITECTS is prohibited. This document may not be used in any unauthorized m a n n e r. (02 0 1 7 t+ N O co 00 > J_ - Cd Cd CO Cd C > LO x /� N N revision: project: 170404 date: 06/29/17 drawn: sb/cb checked: ti permit set plans a1.0 This document is the property of e r s t a d ARCHITECTS and is protected by U.S. and International laws. Use, r e p r o d u c t i o n o r modification of this document without first obtaining the written permission of erstad ARCHITECTS is prohibited. This document may not be used in any unauthorized m a n n e r. (02 0 1 7 t+ N O co 00 > J_ - Cd Cd CO Cd C > LO x /� N N revision: project: 170404 date: 06/29/17 drawn: sb/cb checked: ti permit set plans a1.0 revision: project: 170404 date: 06/29/17 drawn: sb/cb checked: ti permit set plans a1.0 permit set plans a1.0