HomeMy WebLinkAboutTRUSS SPECS - 17-00238-00245,17-00355-00360 - 295 Ella Ln - Kenneth Square - MFREstimate.txt
Roof Plane
Hip Lines,96.88
Horizontal Overhang Lines,136
Raked Overhang Lines,28.6
Ridge Lines1,15.83
Roof Area,1802.12
Valley Lines,19.33
Page 1
Job
B0767-17
Truss
A1
Truss Type
COMMON
Qty
8
Ply
1
Kenneth Square 4-plex
Job Reference (optional)
Run: 7.530 s Jul 14 2014 Print: 8.100 s Jan 25 2017 MiTek Industries, Inc. Thu May 04 09:13:25 2017 Page 1 Snake River Truss & Components, Idaho Falls, ID 83401, Robin Pettingill
ID:QMt4RajSKP0mRetUsyCTQ2yFe0q-qe7uA9Bt7QqG7PFz3x?PWKqRWGRMoZsaaVJhVDzJvhe
Scale = 1:18.6
T1
T2
B1
W2
W1
1
2
3
4
5
3x4
2x4
3x4
4x4
8-0-0
8-0-0
-1-0-0
1-0-0
5-6-0
5-6-0
8-0-0
2-6-0
0-
4
-
2
2-
1
0
-
6
1-
8
-
1
0
5.50 12
Plate Offsets (X,Y)-- [2:0-2-0,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
8.0
0.0 *
8.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MP
0.44
0.33
0.08
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.12
-0.29
0.00
0.05
(loc)
5-8
5-8
2
5-8
l/defl
>805
>326
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 31 lb FT = 0%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) 2=498/0-5-8 (min. 0-1-8), 5=394/Mechanical
Max Horz2=58(LC 7)
Max Uplift2=-63(LC 8), 5=-31(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-294/39
WEBS 3-5=-302/43
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip
DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 63 lb uplift at joint 2 and 31 lb uplift at joint 5.
7) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
B0767-17
Truss
A1G
Truss Type
Common Supported Gable
Qty
2
Ply
1
Kenneth Square 4-plex
Job Reference (optional)
Run: 7.530 s Jul 14 2014 Print: 8.100 s Jan 25 2017 MiTek Industries, Inc. Thu May 04 09:13:25 2017 Page 1 Snake River Truss & Components, Idaho Falls, ID 83401, Robin Pettingill
ID:QMt4RajSKP0mRetUsyCTQ2yFe0q-qe7uA9Bt7QqG7PFz3x?PWKqWeGVPoaFaaVJhVDzJvhe
Scale = 1:19.6
T1
T2
B1
ST2
ST1 ST1
1
2
3
4
5
6
9 8 7
4x4
3x4 3x4 2x4 2x4
2x4
2x4
2x4
11-0-0
11-0-0
-1-0-0
1-0-0
5-6-0
5-6-0
11-0-0
5-6-0
0-
4
-
2
2-
1
0
-
6
0-
4
-
2
5.50 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
8.0
0.0 *
8.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-R
0.11
0.07
0.06
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.00
0.00
0.00
(loc)
1
1
6
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 40 lb FT = 0%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 11-0-0.
(lb) - Max Horz2=45(LC 8)
Max Uplift All uplift 100 lb or less at joint(s) 6, 2, 9, 7
Max Grav All reactions 250 lb or less at joint(s) 6, 8 except 2=258(LC 1), 9=348(LC 1), 7=374(LC 20)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 3-9=-276/87, 5-7=-289/90
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip
DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Gable requires continuous bottom chord bearing.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 2, 9, 7.
9) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 2.
10) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
B0767-17
Truss
B1
Truss Type
Hip Girder
Qty
2
Ply
2
Kenneth Square 4-plex
Job Reference (optional)
Run: 7.530 s Jul 14 2014 Print: 8.100 s Jan 25 2017 MiTek Industries, Inc. Thu May 04 09:13:27 2017 Page 1 Snake River Truss & Components, Idaho Falls, ID 83401, Robin Pettingill
ID:QMt4RajSKP0mRetUsyCTQ2yFe0q-m1FebrD7e24zMjPLAM2tclwi54_TGHst1pona6zJvhc
Scale = 1:63.3
T1
T2
T3
B1
W1
W2 W3 W4 W3 W4 W3
W2
W1
T2
B3B2
1
2
3 4 5 6 7
8
9 10
16 15 14 13 12 1117 18 19 20 21 22 23 24 25 26 27 28
4x8
5x6
3x8
7x10 MT20HS6x8
2x4
3x8
2x4
2x4
5x8
5x6
4x4
2x4
4x8 M18SHS
4x8
7-10-8
7-10-8
14-10-4
6-11-12
21-11-12
7-1-8
28-11-8
6-11-12
36-11-8
8-0-0
4-4-4
4-4-4
7-10-8
3-6-4
14-10-4
6-11-12
21-11-12
7-1-8
28-11-8
6-11-12
32-5-12
3-6-4
36-11-8
4-5-12
37-11-8
1-0-0
0-
4
-
1
3
3-
1
0
-
7
4-
0
-
2
0-
4
-
2
3-
1
0
-
7
5.50 12
Plate Offsets (X,Y)-- [4:0-2-8,0-1-8], [7:0-2-12,0-1-12], [13:0-2-0,0-2-8], [16:0-4-0,0-3-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
8.0
0.0 *
8.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-R
0.75
0.87
0.88
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.58
-0.94
0.20
0.26
(loc)
13-14
13-14
9
13-14
l/defl
>751
>466
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
MT20HS
M18SHS
Weight: 381 lb FT = 0%
GRIP
220/195
165/146
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr *Except*
T2: 2x4 DF 2400F 2.0E
BOT CHORD 2x6 DF 1800F 1.6E
WEBS 2x4 DF Stud/Std *Except*
W3: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-0-7 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size) 1=5145/0-4-0 (min. 0-2-12), 9=4683/0-5-8 (min. 0-2-8)
Max Horz1=-60(LC 28)
Max Uplift1=-727(LC 5), 9=-721(LC 4)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-10130/1548, 2-3=-10031/1580, 3-4=-9012/1441, 4-5=-13363/2299, 5-6=-13363/2299,
6-7=-13366/2300, 7-8=-10134/1713, 8-9=-10204/1675
BOT CHORD 1-17=-1369/9087, 17-18=-1369/9087, 18-19=-1369/9087, 19-20=-1369/9087,
16-20=-1369/9087, 16-21=-2187/13259, 21-22=-2187/13259, 15-22=-2187/13259,
15-23=-2187/13259, 14-23=-2187/13259, 14-24=-2187/13259, 24-25=-2187/13259,
25-26=-2187/13259, 13-26=-2187/13259, 13-27=-1500/9199, 12-27=-1500/9199,
12-28=-1500/9199, 11-28=-1500/9199, 9-11=-1474/9127
WEBS 2-16=-155/384, 3-16=-538/3600, 4-16=-4867/925, 4-14=-212/1338, 6-13=-723/176,
7-13=-833/4801, 7-11=-267/1525, 8-11=-177/458
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip
DOL=1.60
5) Provide adequate drainage to prevent water ponding.
6) All plates are MT20 plates unless otherwise indicated.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=727,
9=721.
10) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
Continued on page 2
Job
B0767-17
Truss
B1
Truss Type
Hip Girder
Qty
2
Ply
2
Kenneth Square 4-plex
Job Reference (optional)
Run: 7.530 s Jul 14 2014 Print: 8.100 s Jan 25 2017 MiTek Industries, Inc. Thu May 04 09:13:27 2017 Page 2 Snake River Truss & Components, Idaho Falls, ID 83401, Robin Pettingill
ID:QMt4RajSKP0mRetUsyCTQ2yFe0q-m1FebrD7e24zMjPLAM2tclwi54_TGHst1pona6zJvhc
NOTES-
11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 336 lb down and 45 lb up at 0-10-12, 336 lb down and 45 lb up at 2-10-12
, 336 lb down and 45 lb up at 4-10-12, 336 lb down and 45 lb up at 6-10-12, 361 lb down and 83 lb up at 8-10-12, 361 lb down and 83 lb up at 10-10-12, 361 lb down and 83
lb up at 12-10-12, 361 lb down and 83 lb up at 14-10-12, 361 lb down and 83 lb up at 16-10-12, 361 lb down and 83 lb up at 18-10-12, 361 lb down and 83 lb up at
20-10-12, 361 lb down and 83 lb up at 22-10-12, 361 lb down and 83 lb up at 24-10-12, and 361 lb down and 83 lb up at 26-10-12, and 1032 lb down and 232 lb up at
28-10-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-3=-86, 3-7=-86, 7-10=-86, 1-9=-16
Concentrated Loads (lb)
Vert: 14=-361(B) 11=-1032(B) 12=-361(B) 17=-336(B) 18=-336(B) 19=-336(B) 20=-336(B) 21=-361(B) 22=-361(B) 23=-361(B) 24=-361(B) 25=-361(B) 26=-361(B)
27=-361(B) 28=-361(B)
Job
B0767-17
Truss
B2
Truss Type
HIP
Qty
2
Ply
1
Kenneth Square 4-plex
Job Reference (optional)
Run: 7.530 s Jul 14 2014 Print: 8.100 s Jan 25 2017 MiTek Industries, Inc. Thu May 04 09:13:28 2017 Page 1 Snake River Truss & Components, Idaho Falls, ID 83401, Robin Pettingill
ID:QMt4RajSKP0mRetUsyCTQ2yFe0q-EDo1pBDmPLCq_t_Yk4Z68ySxQUN6?qP0GTXL6YzJvhb
Scale: 3/16"=1'
T1
T2
T3
B1
W1
W2
W3
W4 W4
W3
W2
W1
T2
B3B2SB1SB2
1
2
3 4 5 6
7
8
9 10
15 14 13 12 113x6
5x6
3x6
5x6 WB3x8
2x4
3x4
3x4
3x4
3x8
2x4
5x6
5x6 WB
3x6
9-10-8
9-10-8
18-5-0
8-6-8
26-11-8
8-6-8
36-11-8
10-0-0
5-2-1
5-2-1
9-10-8
4-8-7
15-6-13
5-8-5
21-3-3
5-8-5
26-11-8
5-8-5
31-7-15
4-8-7
36-11-8
5-3-9
37-11-8
1-0-0
0-
4
-
1
3
4-
9
-
7
4-
1
1
-
2
0-
4
-
2
4-
9
-
7
5.50 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
8.0
0.0 *
8.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.46
0.65
0.41
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.35
-0.63
0.21
0.13
(loc)
13
11-13
9
13
l/defl
>999
>701
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 165 lb FT = 0%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
WEBS 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-11-15 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 4-15, 6-11
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) 1=1863/0-4-0 (min. 0-2-0), 9=1978/0-5-8 (min. 0-2-2)
Max Horz1=-71(LC 9)
Max Uplift1=-132(LC 5), 9=-141(LC 4)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-3739/324, 2-3=-3347/304, 3-4=-2947/289, 4-5=-3773/384, 5-6=-3773/384,
6-7=-2951/290, 7-8=-3350/304, 8-9=-3768/325
BOT CHORD 1-15=-263/3302, 14-15=-329/3733, 13-14=-329/3733, 12-13=-321/3734, 11-12=-321/3734,
9-11=-251/3315
WEBS 2-15=-379/158, 3-15=-40/939, 4-15=-1149/174, 6-11=-1144/174, 7-11=-40/939,
8-11=-389/157
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=132,
9=141.
7) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
B0767-17
Truss
B3
Truss Type
HIP
Qty
2
Ply
1
Kenneth Square 4-plex
Job Reference (optional)
Run: 7.530 s Jul 14 2014 Print: 8.100 s Jan 25 2017 MiTek Industries, Inc. Thu May 04 09:13:29 2017 Page 1 Snake River Truss & Components, Idaho Falls, ID 83401, Robin Pettingill
ID:QMt4RajSKP0mRetUsyCTQ2yFe0q-jPMP0WEOAfKhc1ZkIn4Lh9?4Cti2kHlAV7Hue?zJvha
Scale: 3/16"=1'
T1
T2
T1
B1
W1
W2
W3
W4
W3
W2
W1
B1B21
2
3
4 5 6
7
8 9
12 11 10
5x6
5x6
3x6
5x8
2x4
2x4 5x8
3x8
2x4
3x6
12-0-0
12-0-0
18-6-8
6-6-8
25-1-0
6-6-8
37-1-0
12-0-0
-1-0-0
1-0-0
6-3-9
6-3-9
12-0-0
5-8-7
18-6-8
6-6-8
25-1-0
6-6-8
30-9-7
5-8-7
37-1-0
6-3-9
38-1-0
1-0-0
0-
4
-
2
5-
8
-
7
5-
1
0
-
2
0-
4
-
2
5-
8
-
7
5.50 12
Plate Offsets (X,Y)-- [2:0-0-1,Edge], [8:0-0-1,Edge], [10:0-3-12,0-3-0], [12:0-3-12,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
8.0
0.0 *
8.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.58
0.73
0.41
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.40
-0.95
0.20
0.10
(loc)
2-12
2-12
8
11
l/defl
>999
>463
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 167 lb FT = 0%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-9-5 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 5-12, 5-10
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) 2=1979/0-5-8 (min. 0-2-2), 8=1979/0-5-8 (min. 0-2-2)
Max Horz2=-77(LC 13)
Max Uplift2=-154(LC 8), 8=-154(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3700/279, 3-4=-3154/247, 4-5=-2766/241, 5-6=-2766/241, 6-7=-3154/247,
7-8=-3700/279
BOT CHORD 2-12=-256/3271, 11-12=-218/3212, 10-11=-218/3212, 8-10=-204/3271
WEBS 3-12=-567/193, 4-12=-7/796, 5-12=-798/123, 5-10=-798/123, 6-10=-7/796, 7-10=-567/193
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=154,
8=154.
7) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
B0767-17
Truss
B4
Truss Type
HIP
Qty
2
Ply
1
Kenneth Square 4-plex
Job Reference (optional)
Run: 7.530 s Jul 14 2014 Print: 8.100 s Jan 25 2017 MiTek Industries, Inc. Thu May 04 09:13:29 2017 Page 1 Snake River Truss & Components, Idaho Falls, ID 83401, Robin Pettingill
ID:QMt4RajSKP0mRetUsyCTQ2yFe0q-jPMP0WEOAfKhc1ZkIn4Lh9?3Ktj0kBmAV7Hue?zJvha
Scale = 1:65.2
T2
T3
T2
B1
W1 W2
W3 W4 W4
W3
W2 W1T1 T1
B1B212
3
4
5 6 7
8
9
10 11
17 16 15 14 13 1218 19
3x6
5x6
5x6
3x6
3x6
4x6
3x4
2x4 3x8
3x4
3x8
3x4
2x4 4x6
3x6
7-3-9
7-3-9
14-0-0
6-8-7
23-1-0
9-1-0
29-9-7
6-8-7
37-1-0
7-3-9
-1-0-0
1-0-0
7-3-9
7-3-9
14-0-0
6-8-7
18-6-8
4-6-8
23-1-0
4-6-8
29-9-7
6-8-7
37-1-0
7-3-9
38-1-0
1-0-0
0-
4
-
2
6-
7
-
7
6-
9
-
2
0-
4
-
2
6-
7
-
7
5.50 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
8.0
0.0 *
8.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.70
0.67
0.79
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.37
-0.72
0.19
0.09
(loc)
14-15
14-15
10
14-15
l/defl
>999
>615
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 172 lb FT = 0%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-5-3 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) 2=1979/0-5-8 (min. 0-2-2), 10=1979/0-5-8 (min. 0-2-2)
Max Horz2=-89(LC 9)
Max Uplift2=-169(LC 8), 10=-169(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3735/270, 3-4=-2925/177, 4-5=-2787/198, 5-6=-2531/207, 6-7=-2531/207,
7-8=-2787/198, 8-9=-2925/177, 9-10=-3735/270
BOT CHORD 2-17=-261/3263, 16-17=-261/3263, 15-16=-261/3263, 15-18=-120/2700, 18-19=-120/2700,
14-19=-120/2700, 13-14=-172/3263, 12-13=-172/3263, 10-12=-172/3263
WEBS 3-15=-825/190, 5-15=-10/734, 6-15=-528/87, 6-14=-528/87, 7-14=-10/734, 9-14=-825/190
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 8.0psf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=169,
10=169.
7) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
B0767-17
Truss
B5
Truss Type
HIP
Qty
2
Ply
1
Kenneth Square 4-plex
Job Reference (optional)
Run: 7.530 s Jul 14 2014 Print: 8.100 s Jan 25 2017 MiTek Industries, Inc. Thu May 04 09:13:30 2017 Page 1 Snake River Truss & Components, Idaho Falls, ID 83401, Robin Pettingill
ID:QMt4RajSKP0mRetUsyCTQ2yFe0q-BcwnEsF0xzSYDA8wrVbaDNXEYH6jTluJjn0RBRzJvhZ
Scale = 1:64.9
T2
T3
T2
B1
W1
W2
W3
W4
W3
W2
W1
T1 T1
B1B212
3 4
5 6
7 8
9 10
16 15 14 13
12 1123
3x6
5x6
5x6
3x6
3x6
4x6
3x4
2x4 3x4 3x8
3x4
2x4 4x6 3x6
8-3-9
8-3-9
16-0-0
7-8-7
21-1-0
5-1-0
28-9-7
7-8-7
37-1-0
8-3-9
-1-0-0
1-0-0
8-3-9
8-3-9
16-0-0
7-8-7
21-1-0
5-1-0
28-9-7
7-8-7
37-1-0
8-3-9
38-1-0
1-0-0
0-
4
-
2
7-
6
-
7
7-
8
-
2
0-
4
-
2
7-
6
-
7
5.50 12
Plate Offsets (X,Y)-- [2:0-3-0,0-1-2], [5:0-3-0,0-1-12], [9:0-3-0,0-1-2]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
8.0
0.0 *
8.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MSH
0.67
0.51
0.35
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.25
-0.47
0.18
0.08
(loc)
14-16
14-16
9
14-16
l/defl
>999
>940
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 171 lb FT = 0%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr *Except*
T2: 2x4 DF 2400F 2.0E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-8-1 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 3-14, 5-13, 8-13
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) 2=1982/0-5-8 (min. 0-2-2), 9=1982/0-5-8 (min. 0-2-2)
Max Horz2=-101(LC 13)
Max Uplift2=-182(LC 8), 9=-182(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3598/277, 3-4=-2693/181, 4-5=-2670/207, 5-6=-2307/224, 6-7=-2671/207,
7-8=-2694/181, 8-9=-3598/278
BOT CHORD 2-16=-269/3149, 15-16=-269/3149, 14-15=-269/3149, 14-23=-91/2307, 13-23=-91/2307,
12-13=-169/3149, 11-12=-169/3149, 9-11=-169/3149
WEBS 3-16=0/282, 3-14=-947/199, 5-14=-37/530, 5-13=-312/314, 6-13=-24/526, 8-13=-947/200,
8-11=0/281
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 8.0psf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=182,
9=182.
7) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
B0767-17
Truss
B6
Truss Type
HIP
Qty
2
Ply
1
Kenneth Square 4-plex
Job Reference (optional)
Run: 7.530 s Jul 14 2014 Print: 8.100 s Jan 25 2017 MiTek Industries, Inc. Thu May 04 09:13:30 2017 Page 1 Snake River Truss & Components, Idaho Falls, ID 83401, Robin Pettingill
ID:QMt4RajSKP0mRetUsyCTQ2yFe0q-BcwnEsF0xzSYDA8wrVbaDNXFeH3DTbsJjn0RBRzJvhZ
Scale = 1:64.9
T2
T3
T2
B1
W1
W2 W3
W4
W5
W4
W3 W2
W1
T1 T1
B1B212
3
4
5
6 7
8
9
10
11 12
18 17 16 15
14 1319 20 21 22
3x6
5x6
5x6
3x6
3x6
4x6 3x4
2x4
3x4
3x8 3x4
3x4
3x4
2x4
4x6
3x6
9-3-9
9-3-9
18-0-0
8-8-7
19-1-0
1-1-0
27-9-7
8-8-7
37-1-0
9-3-9
-1-0-0
1-0-0
6-4-12
6-4-12
12-2-6
5-9-10
18-0-0
5-9-10
19-1-0
1-1-0
24-10-10
5-9-10
30-8-4
5-9-10
37-1-0
6-4-12
38-1-0
1-0-0
0-
4
-
2
8-
5
-
7
8-
7
-
2
0-
4
-
2
8-
5
-
7
5.50 12
Plate Offsets (X,Y)-- [7:0-3-0,0-1-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
8.0
0.0 *
8.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.60
0.67
0.99
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.29
-0.54
0.18
0.09
(loc)
13-15
13-15
11
2-18
l/defl
>999
>809
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 189 lb FT = 0%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-8-5 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 7-16
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) 2=1976/0-3-8 (min. 0-2-2), 11=1983/0-5-8 (min. 0-2-2)
Max Horz2=-113(LC 13)
Max Uplift2=-193(LC 8), 11=-194(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3782/347, 3-4=-3384/292, 4-5=-3193/310, 5-6=-2429/231, 6-7=-2103/236,
7-8=-2425/232, 8-9=-3171/308, 9-10=-3362/289, 10-11=-3748/343
BOT CHORD 2-18=-361/3324, 18-19=-227/2723, 17-19=-227/2723, 17-20=-227/2723, 16-20=-227/2723,
15-16=-76/2098, 15-21=-112/2713, 14-21=-112/2713, 14-22=-112/2713, 13-22=-112/2713,
11-13=-243/3285
WEBS 3-18=-491/160, 5-18=-40/572, 5-16=-875/195, 6-16=-79/656, 7-16=-334/387, 7-15=-92/657,
8-15=-868/195, 8-13=-39/554, 10-13=-468/157
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 8.0psf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=193,
11=194.
7) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
B0767-17
Truss
B6G
Truss Type
GABLE
Qty
2
Ply
1
Kenneth Square 4-plex
Job Reference (optional)
Run: 7.530 s Jul 14 2014 Print: 8.100 s Jan 25 2017 MiTek Industries, Inc. Thu May 04 09:13:33 2017 Page 1 Snake River Truss & Components, Idaho Falls, ID 83401, Robin Pettingill
ID:QMt4RajSKP0mRetUsyCTQ2yFe0q-bBcwsuHuEur74etVXd8Hr?9mMV4jg2XlQkF6nmzJvhW
Scale: 3/16"=1'
T2 T2
B1
W4 W3
W2
W1
W3
W2
W1
T1 T1
B1B2
ST11
ST12
ST9
ST10
ST8
ST6
ST7
ST4
ST5ST3ST2
ST1
ST11
ST12
ST9
ST10
ST8
ST6
ST7
ST4
ST5
ST3 ST2
ST1
1 2
3
4
5
6
7
8
9
10 11
16 15 14 13 1253 54
3x6
5x6
3x6
3x6
4x6 3x8 3x4
4x4
3x4
4x4
4x6
3x6
3x4 3x4
3x6
9-6-13
9-6-13
18-6-8
8-11-11
27-6-3
8-11-11
37-1-0
9-6-13
-1-0-0
1-0-0
6-6-14
6-6-14
12-6-11
5-11-13
18-6-8
5-11-13
24-6-5
5-11-13
30-6-2
5-11-13
37-1-0
6-6-14
38-1-0
1-0-0
0-
4
-
2
8-
1
0
-
1
0-
4
-
2
5.50 12
Plate Offsets (X,Y)-- [5:0-1-12,0-0-10], [7:0-3-0,0-0-10]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
8.0
0.0 *
8.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.64
0.68
0.61
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.29
-0.54
0.18
0.10
(loc)
14-16
12-14
10
2-16
l/defl
>999
>816
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 258 lb FT = 0%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
WEBS 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-7-5 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 7-14, 5-14
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) 2=1976/0-3-8 (min. 0-2-2), 10=1983/0-5-8 (min. 0-2-2)
Max Horz2=-117(LC 13)
Max Uplift2=-195(LC 8), 10=-196(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3771/352, 3-4=-3359/295, 4-5=-3162/314, 5-6=-2352/242, 6-7=-2352/242,
7-8=-3140/312, 8-9=-3337/293, 9-10=-3738/348
BOT CHORD 2-16=-368/3313, 15-16=-230/2686, 15-53=-230/2686, 14-53=-230/2686, 14-54=-118/2677,
13-54=-118/2677, 12-13=-118/2677, 10-12=-247/3275
WEBS 6-14=-105/1390, 7-14=-917/205, 7-12=-41/570, 9-12=-488/162, 5-14=-928/207,
5-16=-43/589, 3-16=-509/165
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip
DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 2x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 8.0psf.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=195,
10=196.
9) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
B0767-17
Truss
CR1
Truss Type
DIAGONAL HIP GIRDER
Qty
2
Ply
1
Kenneth Square 4-plex
Job Reference (optional)
Run: 7.530 s Jul 14 2014 Print: 8.100 s Jan 25 2017 MiTek Industries, Inc. Thu May 04 09:13:33 2017 Page 1 Snake River Truss & Components, Idaho Falls, ID 83401, Robin Pettingill
ID:QMt4RajSKP0mRetUsyCTQ2yFe0q-bBcwsuHuEur74etVXd8Hr?9hlV9wg3VlQkF6nmzJvhW
Scale: 1/2"=1'
T1
W3
B1
W1 W2
1
2
3
4 5
8 7
6
9
10
11 12
3x4
3x4 3x4
3x4
2x4
5-10-8
5-10-8
11-3-0
5-4-8
-1-5-0
1-5-0
5-10-8
5-10-8
11-3-0
5-4-8
0-
4
-
2
3-
1
1
-
1
4
3.89 12
Plate Offsets (X,Y)-- [4:0-2-5,0-0-12], [7:0-1-8,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
8.0
0.0 *
8.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
1-0-0
1.15
1.15
NO
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-SH
0.93
0.35
0.55
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.04
-0.09
0.02
0.02
(loc)
7-8
7-8
7
8
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 47 lb FT = 0%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size) 7=683/Mechanical, 2=541/0-7-6 (min. 0-1-8)
Max Horz2=63(LC 22)
Max Uplift7=-137(LC 8), 2=-112(LC 4)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-9=-1108/202, 3-9=-1041/199, 4-7=-250/84
BOT CHORD 2-11=-229/1022, 8-11=-229/1022, 8-12=-229/1022, 7-12=-229/1022
WEBS 3-8=0/285, 3-7=-1025/218
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip
DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 7=137,
2=112.
6) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 24 lb down and 26 lb up at 2-9-8, 24
lb down and 26 lb up at 2-9-8, 78 lb down and 55 lb up at 5-7-7, 78 lb down and 55 lb up at 5-7-7, and 171 lb down and 84 lb up at
8-5-6, and 171 lb down and 84 lb up at 8-5-6 on top chord, and 9 lb down and 3 lb up at 2-9-8, 9 lb down and 3 lb up at 2-9-8, 41 lb
down at 5-7-7, 41 lb down at 5-7-7, and 77 lb down at 8-5-6, and 77 lb down at 8-5-6 on bottom chord. The design/selection of such
connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-4=-43, 4-5=-8, 2-6=-8
Concentrated Loads (lb)
Vert: 3=-156(F=-78, B=-78) 8=-36(F=-18, B=-18) 9=12(F=6, B=6) 10=-342(F=-171, B=-171) 11=-8(F=-4, B=-4) 12=-68(F=-34,
B=-34)
Job
B0767-17
Truss
J1
Truss Type
Jack-Open
Qty
4
Ply
1
Kenneth Square 4-plex
Job Reference (optional)
Run: 7.530 s Jul 14 2014 Print: 8.100 s Jan 25 2017 MiTek Industries, Inc. Thu May 04 09:13:34 2017 Page 1 Snake River Truss & Components, Idaho Falls, ID 83401, Robin Pettingill
ID:QMt4RajSKP0mRetUsyCTQ2yFe0q-3NAI3EIW?Bz_ioSh4KgWODi3wuaIPeMveO_fKCzJvhV
Scale = 1:8.9
T1
B1
1
2
3
4
2x4
1-11-11
1-11-11
-1-0-0
1-0-0
1-11-11
1-11-11
0-
4
-
2
1-
2
-
1
5
0-
1
0
-
7
1-
2
-
1
5
5.50 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
8.0
0.0 *
8.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.07
0.02
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.00
-0.00
-0.00
0.00
(loc)
2
2-4
3
2
l/defl
>999
>999
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 7 lb FT = 0%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
BRACING-
TOP CHORD Structural wood sheathing directly applied or 1-11-11 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) 3=55/Mechanical, 2=220/0-5-8 (min. 0-1-8), 4=15/Mechanical
Max Horz2=40(LC 8)
Max Uplift3=-21(LC 8), 2=-32(LC 8)
Max Grav3=55(LC 1), 2=220(LC 1), 4=34(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip
DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2.
6) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
B0767-17
Truss
J2
Truss Type
Jack-Open
Qty
4
Ply
1
Kenneth Square 4-plex
Job Reference (optional)
Run: 7.530 s Jul 14 2014 Print: 8.100 s Jan 25 2017 MiTek Industries, Inc. Thu May 04 09:13:34 2017 Page 1 Snake River Truss & Components, Idaho Falls, ID 83401, Robin Pettingill
ID:QMt4RajSKP0mRetUsyCTQ2yFe0q-3NAI3EIW?Bz_ioSh4KgWODi2MuZFPeMveO_fKCzJvhV
Scale = 1:13.4
T1
B1
1
2
3
4
2x4
3-11-11
3-11-11
-1-0-0
1-0-0
3-11-11
3-11-11
0-
4
-
2
2-
1
-
1
5
1-
9
-
7
2-
1
-
1
5
5.50 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
8.0
0.0 *
8.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.17
0.09
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.01
-0.02
-0.00
0.00
(loc)
2-4
2-4
3
2
l/defl
>999
>999
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 13 lb FT = 0%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-11-11 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) 3=139/Mechanical, 2=318/0-5-8 (min. 0-1-8), 4=29/Mechanical
Max Horz2=67(LC 8)
Max Uplift3=-49(LC 8), 2=-38(LC 8)
Max Grav3=139(LC 1), 2=318(LC 1), 4=66(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip
DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2.
6) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
B0767-17
Truss
J3
Truss Type
Jack-Open
Qty
4
Ply
1
Kenneth Square 4-plex
Job Reference (optional)
Run: 7.530 s Jul 14 2014 Print: 8.100 s Jan 25 2017 MiTek Industries, Inc. Thu May 04 09:13:35 2017 Page 1 Snake River Truss & Components, Idaho Falls, ID 83401, Robin Pettingill
ID:QMt4RajSKP0mRetUsyCTQ2yFe0q-XZkgHaJ9mV5rKy0ue2BlwQF7mItL85c2t2kCsezJvhU
Scale = 1:17.8
T1
B1
1
2
3
4
2x4
5-11-11
5-11-11
-1-0-0
1-0-0
5-11-11
5-11-11
0-
4
-
2
3-
0
-
1
5
2-
8
-
7
3-
0
-
1
5
5.50 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
8.0
0.0 *
8.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-P
0.51
0.23
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.05
-0.12
-0.00
0.00
(loc)
2-4
2-4
3
2
l/defl
>999
>566
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 19 lb FT = 0%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-11-11 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) 3=232/Mechanical, 2=413/0-5-8 (min. 0-1-8), 4=45/Mechanical
Max Horz2=95(LC 8)
Max Uplift3=-79(LC 8), 2=-44(LC 8)
Max Grav3=232(LC 1), 2=413(LC 1), 4=102(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip
DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2.
6) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
B0767-17
Truss
LAY01
Truss Type
GABLE
Qty
2
Ply
1
Kenneth Square 4-plex
Job Reference (optional)
Run: 7.530 s Jul 14 2014 Print: 8.100 s Jan 25 2017 MiTek Industries, Inc. Thu May 04 09:13:35 2017 Page 1 Snake River Truss & Components, Idaho Falls, ID 83401, Robin Pettingill
ID:QMt4RajSKP0mRetUsyCTQ2yFe0q-XZkgHaJ9mV5rKy0ue2BlwQFFrIw683y2t2kCsezJvhU
Scale = 1:72.2
T1 T1
B1
ST1
ST2
ST3
ST4
ST5
ST6
ST7
ST8
ST9
B1
1
2
3
4
5
6
7
8
9
10
11
12
22 21 20 19 18
17
16 15 14 13
3x4
3x4
3x4
3x4
21-0-8
21-0-8
10-6-4
10-6-4
21-0-8
10-6-4
0-
0
-
4
11
-
6
-
1
4
0-
0
-
4
13.20 12
Plate Offsets (X,Y)-- [7:Edge,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
8.0
0.0 *
8.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-R
0.06
0.05
0.17
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.01
(loc)
-
-
12
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 144 lb FT = 0%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 5-19, 6-18, 8-16
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 21-0-8.
(lb) - Max Horz1=-223(LC 4)
Max Uplift All uplift 100 lb or less at joint(s) 12, 21, 20, 16, 14 except 1=-107(LC 6), 22=-105(LC 8), 19=-113(LC
8), 15=-118(LC 9), 13=-138(LC 9)
Max Grav All reactions 250 lb or less at joint(s) 1, 12, 22, 21, 20, 19, 18, 16, 15, 14 except 13=285(LC 16)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-337/194, 11-12=-286/143
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip
DOL=1.60
3) All plates are 2x4 MT20 unless otherwise indicated.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 21, 20, 16, 14
except (jt=lb) 1=107, 22=105, 19=113, 15=118, 13=138.
8) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
B0767-17
Truss
M1
Truss Type
JACK-CLOSED
Qty
22
Ply
1
Kenneth Square 4-plex
Job Reference (optional)
Run: 7.530 s Jul 14 2014 Print: 8.100 s Jan 25 2017 MiTek Industries, Inc. Thu May 04 09:13:36 2017 Page 1 Snake River Truss & Components, Idaho Falls, ID 83401, Robin Pettingill
ID:QMt4RajSKP0mRetUsyCTQ2yFe0q-0mH2UwKnXpDix5b4Cli_TenMKiCStW6C6iTmO5zJvhT
Scale = 1:24.4
T1
W2
B1
W1
1
2
3
4
5
2x4
3x4 3x4
2x4
8-0-0
8-0-0
-1-0-0
1-0-0
4-1-13
4-1-13
8-0-0
3-10-3
0-
4
-
2
3-
1
1
-
1
3
3-
8
-
4
5.50 12
Plate Offsets (X,Y)-- [2:0-2-0,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
8.0
0.0 *
8.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2012/TPI2007
CSI.
TC
BC
WB
Matrix-MP
0.27
0.30
0.18
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
-0.10
-0.22
0.01
0.01
(loc)
5-8
5-8
5
5-8
l/defl
>963
>427
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 34 lb FT = 0%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size) 2=498/0-5-8 (min. 0-1-8), 5=394/Mechanical
Max Horz2=122(LC 7)
Max Uplift2=-60(LC 8), 5=-64(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-517/78
BOT CHORD 2-5=-87/452
WEBS 3-5=-501/127
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) V(IRC2012)=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; Cat. II; Exp B; enclosed;
MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip
DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 5.
6) This truss is designed in accordance with the 2012 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
OVERHANG INFO HEEL HEIGHT
GABLE STUDS
2x4
24 IN. OC
END CUT RETURN
SQUARE
REQ. ENGINEERING
NONE
REQ. LAYOUTS
NONE
QUOTE
LAYOUT
CUTTING
DATEBY
S
H
I
P
T
O
,
Valued Customer / Cash Sale
S
O
L
D
T
O
SALES REP
ORDER DATE
REQ. QUOTE DATE
DELIVERY DATE
/ /
/ /
/ /ORDER #
QUOTE #
TERMS
SALES AREA
CUSTOMER PO #
CUSTOMER ACCT #
INVOICE #
000000001
ORDERED BY
SUPERINTENDENT
JOBSITE PHONE #
DATE OF INVOICE
B0767-17
Pettingill
Rexburg
/ /
PAGE 1
SPECIAL INSTRUCTIONS:
DELIVERY INSTRUCTIONS:
JOB NAME:
MODEL: TAG:
Kenneth Square 4-plex
BUILDING DEPARTMENT
N/A
JOB CATEGORY:Residential
LOT # SUBDIV:
DATE05/04/17
Rexburg, ID
Non-Itemized QUOTE Estimate
/ /
/ /
/ /
QTY TYPE
SPAN
LUMBER
TOP BOT
OVERHANG
LEFT RIGHT
CANTILEVER
LEFT RIGHT
PITCH
TOP BOT
ID
PROFILE
ROOF TRUSSES LOADING TCLL-TCDL-BCLL-BCDL
35.0,8.0,0.0,8.0
STRESS INCR.
1.15INFORMATION ROOF TRUSS SPACING:24.0 IN. O.C. (TYP.)
PLY LEFT RIGHT
STUBO/ABASE
SPAN
A1 5.50 0.00 08-00-00 01-00-00
COMMON
8 08-00-00
A1G 5.50 0.00 11-00-00 01-00-00
COMMON
2 11-00-00
B1
2
5.50 0.00 36-11-08 01-00-00
HIP GIRDER
2 Ply 36-11-08
B2 5.50 0.00 36-11-08 01-00-00
HIP
2 36-11-08
B3 5.50 0.00 37-01-00 01-00-00 01-00-00
HIP
2 37-01-00
B4 5.50 0.00 37-01-00 01-00-00 01-00-00
HIP
2 37-01-00
B5 5.50 0.00 37-01-00 01-00-00 01-00-00
HIP
2 37-01-00
B6 5.50 0.00 37-01-00 01-00-00 01-00-00
HIP
2 37-01-00
B6G 5.50 0.00 37-01-00 01-00-00 01-00-00
GABLE
2 37-01-00
CR1 3.89 0.00 11-03-00 01-05-00
DIAGONAL HIP
2 11-03-00
J1 5.50 0.00 01-11-11 01-00-00
JACK-OPEN
4 01-11-11
J2 5.50 0.00 03-11-11 01-00-00
JACK-OPEN
4 03-11-11
J3 5.50 0.00 05-11-11 01-00-00
JACK-OPEN
4 05-11-11
LAY0113.20 0.00 21-00-00
GABLE
2 21-00-00
M1 5.50 0.00 08-00-00 01-00-00
JACK-CLOSED
22 08-00-00
FT-IN-16
ITEM TYPEQTY SIZE
LENGTH PART NUMBER NOTES
ITEMS
00-00-002-Ply NailingGirder Nailing 2 Nailing Charge: 2-Ply Truss
LUS26Hanger 28 DF Snow 990#
THJA26Hanger 2
OVERHANG INFO HEEL HEIGHT
GABLE STUDS
2x4
24 IN. OC
END CUT RETURN
SQUARE
REQ. ENGINEERING
NONE
REQ. LAYOUTS
NONE
QUOTE
LAYOUT
CUTTING
DATEBY
S
H
I
P
T
O
,
Valued Customer / Cash Sale
S
O
L
D
T
O
SALES REP
ORDER DATE
REQ. QUOTE DATE
DELIVERY DATE
/ /
/ /
/ /ORDER #
QUOTE #
TERMS
SALES AREA
CUSTOMER PO #
CUSTOMER ACCT #
INVOICE #
000000001
ORDERED BY
SUPERINTENDENT
JOBSITE PHONE #
DATE OF INVOICE
B0767-17
Pettingill
Rexburg
/ /
PAGE 2
SPECIAL INSTRUCTIONS:
DELIVERY INSTRUCTIONS:
JOB NAME:
MODEL: TAG:
Kenneth Square 4-plex
BUILDING DEPARTMENT
N/A
JOB CATEGORY:Residential
LOT # SUBDIV:
DATE05/04/17
Rexburg, ID
Non-Itemized QUOTE Estimate
/ /
/ /
/ /
ACCEPTED BY BUYER
PURCHASER:
BY: TITLE:
ADDRESS:
PHONE: DATE:
ACCEPTED BY SELLER
BY:
TITLE:
DATE OF ACCEPTANCE:
SUB-TOTAL
GRAND TOTAL
SALES TAX 6.000 %
DELIVERY
$205.47
$3,424.53
$3,630.00
INCLUDED
Prices are only good for 30 days. All orders will be adjusted for current lumber costs
at time of production if beyond 30 days of bid or order date.