HomeMy WebLinkAboutPLAN REVIEW BLDG 1 - 02-00057 - Ray Loveland Dance StudioOQR�VRCi // //-� ��//yy// P.O. Box 280 �'- cliv �� �G v,14 �U/QQ l% 12 North Center Street „ Rexburg, Idaho 83440 U , F - ° Phone (208) 359-3020 STATE OF IDAHO Fax (208) 359-3022 e<rSHEO www.ci.rexburgJd.us e-mail rexburg@ci.rexburg.id.us 9/18/2002 John Watson JRW 49 Professional Plaza Rexburg, Idaho 83440 Dear John, I have reviewed the drawings for the Ray Loveland Dance building and have identified the following deficiencies: 1. Identify parking lot drainage. 2. Please show two doors for exits at the dance room Make sure that one door opens directly outside or into a properly constructed corridor. 3. If corridor is created, identify corridor construction. Show fire dampers if necessary. identity rated windows and doors in corridor. 4. Show exit signs and emergency lighting on plans. 5. Provide details for handicap shower. 6. Please provide mechanical details. 7. The Fire Department has reviewed the plans. I have attached a copy of the report. Please provide the necessary information they have requested. These items need to be addressed before issuance of a building permit. Please let me know if you have any questions. I can be reached during the day at 359-3020 Ext. 324. Sincerely, Val Christensen Building Official C.C. John Millar Chris Huskinson REXBURG MADISON COUNTY FIRE DEPARTMENT P.O. Box 280 26 North Center Rexburg, Idaho 83440 (208) 359-3010 1997 Uniform Fire Code Plan Date: 7-02 Plan Review Review Date: 8-16-02 Building Name: RAY LOVELAND DANCE STUDIO Building Address: FIFTH WEST, REXBURG Stories: ONE Type of Construction: V -N Occupancy Classification: S-3, A-3 Existing Floor Area: N/A New Construction Floor Area: APPROXIMATELY 6,379 SQUARE FEET 1).Required Fire Flow (Appendix III -A): 2250 GPM FOR TWO HOURS Comments: FIRE FLOW REQUIREMENTS MAY BE REDUCED BY 75% IF EACH BUILDING HAS AN APPROVED AUTOMATIC FIRE SPRINKLER SYSTEM 2).Water Supply (Article 9, Section 903) Required: YES Fire Hydrant Location: C-53, C-72 Fire Hydrant Flows: OR Fire Flow Test Location: SAME AS ABOVE Fire Flow Supplied By: FD Other Approved Water Source: NONE Water Supply Acceptable: YES Fire Hydrant Location Acceptable: YES Water Supply Comments: NONE 3.)Fire Apparatus Access Roads (Article 9 Section 902) Required: YES Acceptable: Width: YES Length: YES Complete Road Acceptable: YES Comments: NONE 4).Access Roads and Water Supply, Including Fire Hydrants Are Required To Be Installed And Made Serviceable Prior To And During Time Of Construction (Article 9 Section 901.3): YES Comments: IF NOT INSTALLED PRIOR TO CONSTRUCTION AND MADE OPERATIONAL, A STOP WORK ORDER WILL BE ISSUED. 5),Installation Of Portable Fire Extinguisher (Article 10 Section 1002) Required: YES Location Acceptable:,NOT SHOWN Type Provided Acceptable: MINIMUM SIZE OF 2A10BC REQUIRED IN EACH UNIT WITHIN TRAVEL DISTANCES Comments: TO BE MOUNTED ON A WALL 6).Automatic Fire Extinguishing Systems: (Article 10 Section 1003 Required: NO Type Of System Being Installed: Sprinkler System Monitoring Required (Article 10 Section 1003.3) Required: Comments: 7).Standpipes (Article 10 Section 1004) Required: NO Type Required: Comments; 8).Ventilating Hood And Duct Fire Extinguishing System (Article 10 Section 1006.2) Required: NO Type Being Provided: Automatic Fuel Shutoff Shown (Article 10 Section 1006.2.4): Portable Fire Extinguisher Shown (Article 10 section 1006.2.7): Comments: 9).Fire Alarm Systems (Article 10 Section 1007)Required: NO Type Of System Required: Manual: Automatic: Both: Type Of System Being Provided: Manual: Automatic: Both: Components Of System Shown: Smoke Detectors: Heat Detectors: Manual Pull Station: Sounding Devices: Visual Devices: Door Holders: Duct Detectors: Flow Alarm: Sprinkler Valve Monitoring: Comments: NONE Fire Alarm System Acceptable: N/A 10).Other Corrections That Are Required By Special Occupancy Or Conditions: Plans As Submitted Are Acceptable: YES Plans Checked By: CHRIS HUSKINSON Date: 8-16-02 Please furnish comments back to the plan reviewer in the following manner: Written Comments: New Plans: