HomeMy WebLinkAboutREVEIW - 02-00006 - Nauvoo Apartments1/28/2002
Jared Sommers
Nauvoo House
175 West 5'h South
Rexburg,ID 83440
Dear Jared,
STATE OF IDAHO
P.O. Box 280
12 North Center Street
Rexburg, Idaho 83440
Phone (208) 359-3020
Fax (208) 359-3022
e-mail rexburg@ci.rexburg.id.us
I have reviewed the plans for Nauvoo II and have identified the following
discrepancies:
1. On page S-8 the snow load is listed at 30 lb/sq. ft. when it should be listed as
35 lb/sq. ft. Please re -do calculations based on this information and provide
us with copies of any changes.
2. The 1997 Uniform Building Code (UBC) Section 310.2.2 requires that the
building be constructed as 1 -hr. fire resistive. Please identify on plans that the
building is to be built as Type V-1 hr.
3. On page A-5, show fire -blocking where floors and roof meet adjacent stud
walls.
4. The Fire Department has not reviewed the drawings at this time. We need
another complete set of plans.
Please provide me with 2 new copies of the corrected plans. If you have any
questions, please give me a call at 359-3020 ext. 324.
Sincerely,
Val Christensen
Building Official
C.C. John Millar
Chris Huskinson