HomeMy WebLinkAboutREVEIW - 02-00006 - Nauvoo Apartments1/28/2002 Jared Sommers Nauvoo House 175 West 5'h South Rexburg,ID 83440 Dear Jared, STATE OF IDAHO P.O. Box 280 12 North Center Street Rexburg, Idaho 83440 Phone (208) 359-3020 Fax (208) 359-3022 e-mail rexburg@ci.rexburg.id.us I have reviewed the plans for Nauvoo II and have identified the following discrepancies: 1. On page S-8 the snow load is listed at 30 lb/sq. ft. when it should be listed as 35 lb/sq. ft. Please re -do calculations based on this information and provide us with copies of any changes. 2. The 1997 Uniform Building Code (UBC) Section 310.2.2 requires that the building be constructed as 1 -hr. fire resistive. Please identify on plans that the building is to be built as Type V-1 hr. 3. On page A-5, show fire -blocking where floors and roof meet adjacent stud walls. 4. The Fire Department has not reviewed the drawings at this time. We need another complete set of plans. Please provide me with 2 new copies of the corrected plans. If you have any questions, please give me a call at 359-3020 ext. 324. Sincerely, Val Christensen Building Official C.C. John Millar Chris Huskinson