Loading...
HomeMy WebLinkAboutPLAN REVIEW - 02-00083 - University Courtyard - 6 Buildings (90 Units) (2)11/-14/2002 Scott Spaulding Design Intelligence 3685 E Hwy. 33 Rexburg, Idaho 93440 Dear Scott, edy (012exIM7.7 STATE OF IDAHO www.drexbura.d.us P.O. Box 280 12 North Center Street Rexburg, Idaho 83440 Phone (208) 359-3020 Fax (208) 359-3022 e-mail rexburg@ci.rexburg.id.us I have reviewed the University Courtyard Apartment drawings that you have provided me and have identified the following discrepancies - 1. The Fair Housing Guidelines requires that handicapped parking spaces to be located on the shortest route to the accessible entrance of the building. This plan has all of the handicapped spaces located across the parking lot. 2. Too many of the parking spaces are designated as compact spaces. The zoning ordinance allows only 25% of the spaces to be compact spaces. 3. Barriers at the spaces between the parking lot and Harvard Avenue must be shown on plans. In past plans, large rocks were shown in these areas. The concern is that in the winter drivers will not be able to distinguish that approaches are not connecting Harvard and the parking lot. Harvard is a very narrow street and the City does not want additional traffic on this street. 4. Please identify Right -Of -Way on both streets and the set -backs from the buildings to the Right -Of -Way on the site plan. 5. Please identify access approaches on 2d East as per the City of Rexburg Specifications. 6. Be aware that plumbing in party walls can cause many problems with the integrity of the fire wail. Plastic pipes can not penetrate the membrane of the 1 -hour firewall unless they are properly constructed to do so. Special fire resistive rings are required or special details that show metal parts entering the membrane and all plastic remaining within the wall. 7. Any room containing gas furnaces or water heaters can not open into a bedroom without a door that seals tight when closed. Exterior doors with tight fitting weather stripping and thresholds are permitted for this application. 8. Furnace rooms have not been identified on these drawings. Please identify the type of finvace. 9. Please identify smoke detectors and fire extinguishers in each unit. 10. Page SO calls out for 5/8" roof sheathing to be blocked on all edges. Is this requirement necessitated by structural design? it is not a common practice in this area. 11. Please identify all footings as being a minimum of 36" below grade. 12. The Fire Department has reviewed the plans. I have attached a copy of there report. Please provide the necessary information they have requested. Please return two sets of revised plans. Let me know if I can be of any further assistance. If you have any questions, please give me a call at 359-3020 ext. 324. Sincerely, Val Christensen Building Official cc John Millar Chris Huskinson REXBURG MADISON COUNTY FIRE DEPARTMENT P.O. Box 280 26 North Center Rexburg, Idaho 83440 (208) 359-3010 1997 Uniform Fire Code Plan Date: 4-02 Plan Review Review Date: 11-14-02 Building Name: MISSION_HOME/UNIVERSITY COURTYARD Building Address: 455 SOUTH SECOND EAST Stories: 2.5 Type of Construction: V -N Occupancy Classification: R-1 Existing Floor Area: 4766 SF New Construction Floor Area: APPROXIMATELY 7140/UNIT 1).Required Fire Flow (Appendix III -A): 2250 GPM/TWO HOURS Comments: THE FIRE FLOW REQUIREMENT MAY BE REDUCED TO 1500 GPM/TWO HOURS IF AN AUTOMATIC FIRE SPRINKLER SYSTEM IS INSTALLED IN EACH BUILDING. 2).Water Supply (Article 9, Section 903) Required: YES Fire Hydrant Location: OKAY Fire Hydrant Flows: EXISTING HYDRANT OKAY, PROPOSED ARE UNKNOWN Fire Flow Test Location: HARVARD AVE. Fire Flow Supplied By: FD Other Approved Water Source: NONE Water Supply Acceptable: YES Fire Hydrant Location Acceptable: YES, SEE COMMENTS. Water Supply Comments: EXISTING HYDRANT ON HARVARD OF LITTLE VALUE TO PROPOSED BUILDINGS ON WEST SIDE OF PROPERTY. THE FIRE DEPARTMENT HAS NO APPARATUS ACCESS THROUGH PROPERTY TO UTILIZE HYDRANT. 3.)Fire Apparatus Access Roads (Article 9 Section 902) Required: YES Acceptable: Width: NO Length: X Surface: X Turning Radius: X Grade: X Vehicle Vertical: X Clearance: X Turn Arounds: X Complete Road Acceptable: NO, SEE COMMENTS. Comments: COMPLEX HAS TWO ACCESS'S THAT NARROW TO 15 FEET WIDE THROUGH PARKING LOT. UFC REQUIRES A MINIMUM OF 20 FEET. ACCESS THROUGH PARKING LOT GRANTED FROM HARVARD AVE._ (NORTH END OF PROPERTY) COULD IMPROVE THE SITUATION AND/OR WIDEN ONE OF THE PARKING LOT ISLES TO 20 FEET. 4).Access Roads and Water Supply, Including Fire Hydrants Are Required To Be Installed And Made Serviceable Prior To And During Time Of Construction (Article 9 Section 901.3): YES Comments: IF NOT INSTALLED PRIOR TO CONSTRUCTION A STOP WORK ORDER WILL BE ISSUED. 5),Installation Of Portable Fire Extinguisher (Article 10 Section 1002) Required: YES Location Acceptable: NOT SHOWN Type Provided Acceptable: NOT SHOWN Comments: MINIMUM OF 2A10BC REQUIRED IN EACH UNIT AND COMMON AREAS. 6).Automatic Fire Extinguishing Systems: (Article 10 Section 1003 Required: NO Type Of System Being Installed: Sprinkler System Monitoring Required (Article 10 Section 1003.3) Required: NO Comments 7).Standpipes (Article 10 Section 1004) Required: Type Required: NO Comments: 8).Ventilating Hood And Duct Fire Extinguishing System (Article 10 Section 1006.2) Required: NO Type Being Provided: Automatic Fuel Shutoff Shown (Article 10 Section 1006.2.4): Portable Fire Extinguisher Shown (Article 10 section 1006.2.7): Comments: 9).Fire Alarm Systems (Article 10 Section 1007)Required: YES Type Of System Required: Manual: Automatic: X Both: Type Of System Being Provided: Manual: Automatic: Both: M Components Of System Shown: Smoke Detectors: Heat Detectors: Manual Pull Station: Sounding Devices: Visual Devices: Door Holders: Duct Detectors: Flow Alarm: Sprinkler Valve Monitoring: Fire Alarm System Acceptable: NO, SMOKE DETECTORS REQUIRED IN EACH SLEEPING ROOM AND CORRIDOR ADJACENT TO SLEEPING ROOMS. HANDICAPPED UNITS REQUIRE HORN/STROBE UNITS WITH BATTERY BACKUP. 10).Other Corrections That Are Required By Special Occupancy Or Conditions: Plans As Submitted Are Acceptable: NO Plans Checked By: CHRIS HUSKINSON Date: 11-14-02 Please furnish comments back to the plan reviewer in the following manner: Written Comments: X New Plans: X