HomeMy WebLinkAboutPLAN REVIEWS - 03-00050 - Teton River Village Building #1 - 8 Units (2)8/27/2003 Lynn Morgan 2939 South -Main Street Salt Lake City, UT 84115 Dear Lynn, Ody 012exiary STATE OF IDAHO www.cj.rexburgJd.us LIiV 7HrU� P.O. Box 280 12 North Center Street Rexburg, Idaho 83440 Phone (208) 359-3020 Fax (208) 359-3022 e-mail rexburg@ci.rexburg.id.us I have reviewed the drawings f8I buildin #1 d the site plan of the Teton River Village (identified on the plans as American Family Entertainment Center) and have identified the following deficiencies: 1. Provide a handicap parking space adjacent to building #2. The closest handicap parking spaces are located across a vehicle access aisle. 2. Please provide a Flood Elevation Certificate as required in the 2000 International Building Code (IBC) Section 1612.5. 3. The geotechnical investigation for this site (included in the project Manual dated July 14, 2003) describes the site as being located in Seismic Zone 2B. This zone is from the 1997 Uniform Building Code (UBC). Rexburg is located in Seismic Zone 3 in the UBC. The structural design is consistent with Chapter 16 of the International Building Code. My concern is that the Geotechnical firm may have made recommendations based on this information. Provide me with a letter from this firm addressing the discrepancy. Design should be applicable to the 2000 IBC. 4. The envelope compliance energy calculations for that have been provided are for the Idaho Falls area. Our climate zone is different than Idaho Falls. The energy calculations should be for climate zone 16 of the 2000 International Energy Conservation Code. 5. The Fire Department has reviewed the plans. I have attached a copy of the report. Please provide the necessary information they have requested. These items need to be addressed before issuance of a building permit. Please let me know if you have any questions. I can be reached during the day at 359-3020 Ext. 324. Sincerely, Val Christensen Building Official C.C. John Millar Chris Huskinson REXBURG-MADISON COUNTY EMERGENCYSER VICES 26 NORTH CENTER STREET REXBURG, IDAHO 83440 208-359-3010 208-359-3006 FAX 2000 International Fire Code Plan Review Plan Date: 7-14-03 Review Date: 7-22-03 Building Name: AMERICAN FAMILY ENTERTAINMENT COMPLEX Building Address: 485 NORTH SECOND EAST, REXBURG, IDAHO Stories: 2 Type of Construction: H -B Occupancy Classification: A-1, A-3 Existing Floor Area: N/A New Construction Floor Area: 46,242 SQUARE FEET 1. Required Fire Flow (Appendix B): 4,500 GPM/FOUR HOURS Comments: NONE 2. Water Supply (Section 508, Appendix C) Required: YES Fire Hydrant Location: NOT ENOUGH HYDRANTS ON SITE PLAN FOR REVIEW Fire Hydrant Flows: Fire Flow Test Location: Fire Flow Supplied By: Other Approved Water Source: Water Supply Acceptable: NO Fire Hydrant Location Acceptable: NO Water Supply Comments: REQUIRED WATER FLOW INCLUDING SIZE AND TYPE OF STRUCTURE INDICATE A MINIMUM OF FIVE HYDRANTS WITHIN 300 OF STRUCTURE. 3. Fire Apparatus Access Roads (Section 503, Appendix D) Required: YES Acceptable Width: NO Complete Road Acceptable: YES Length: YES Surface: YES Comments: CERTAIN AREAS IN COMPLEX SHOW ACCESS UNDER 20 FEET WIDE, PLEASE ADDRESS. 4. Access Roads and Water Supply, including fire hydrants are required to be installed and made serviceable prior to and during time of construction (Section 501): Comments: IF NOT INSTALLED PRIOR TO CONSTRUCTION AND MADE OPERATIONAL, A STOP WORK ORDER WILL BE ISSUED. 5. Installation of portable fire extinguishers (Section 906) Required: YES Location shown: NOT SHOWN Type provided acceptable: NOT SHOWN Comments: INSTALL MINIMUM 2AIOBC WITHIN REQUIRED TRAVEL DISTANCES. 6. Automatic fire extinguishing systems (Section 903) Required: YES Type of system being installed: UNKNOWN Sprinkler system monitoring (Section 907) required: YES Comments: PLEASE SUBMIT FIRE SPRINKLER PLANS TO STATE FIRE MARSHAL FOR REVIEW. 7. Standpipes (Section 905) required: NO Type required: Comments: 8. Ventilating hood and duct fire extinguisher system (Section 609) required: YES Type being provided: UNKNOWN Automatic fuel shut-off required: YES WITH GAS APPLIANCES Portable fire extinguisher shown: NOT SHOWN Comments: PLEASE PROVIDE DETAILS 9. Fire alarm systems (Section 907) required: YES Type of system required: Manual: Type of system being provided: Manual Automatic: Automatic Both: X Both: X Components of system shown: Smoke Detectors: X Heat Detectors: X Manual Pull Station: X Sounding Devices: X Visual Devices: X Door Holders: Duct Detectors: X Flow Alarm: Sprinkler Valve Monitoring: REQUIRED Fire Alarm System Acceptable: NO, SEE COMMENTS BELOW 10. Other corrections that are required by special occupancy or conditions: ADDRESS ALL ITEMS IN QUESTION Plans as submitted are acceptable: NO Plans checked by: CHRIS HUSKINSON Date: 7-22-03 Please furnish comments back to the plan reviewer in the following manner: Written Comments: X New Plans: X ALARM SYSTEM NOTES: -VOICE EVACUATION SYSTEM IS REQUIRED IN COMPLEX AS OCCUPANCY EXCEEDS 1,000 -ADD AT LEAST ONE HORN/STROBE UNIT IN MAIN LOBBY AREA FOR ADEQUATE COVERAGE -DRAWING SHOWS STROBE ONLY UNITS PERIDOCALLY, REPLACE ALL WITH HORN/STROBE UNITS. -ADD SMOKE DETECTORS THROUGHOUT BUILDING (REFERENCE NPFA 16.4.7.4) -CONSTRUCTION DOCUMENTS SHALL INCLUDE: ALARM CONTROL AND TROUBLE SIGNALING EQUIPMENT, ANNUNCIATION, POWER CONNECTION, BATTERY CALCULATIONS, CONDUCTOR TYPE AND SIZES, VOLTAGE DROP CALCULATIONS, MANUFACTURERS, MODEL NUMBERS AND LISTING INFORMATION FOR EQUIPMENT, DEVICES AND MATERIALS, AND INTERFACE OF FIRE SAFETY CONTROL FUNCTIONS.