HomeMy WebLinkAboutPLAN REVIEWS - 03-00050 - Teton River Village Building #1 - 8 Units8/27/2003 Lynn Morgan 2939 South -Main Street Salt Lake City, UT 84115 Dear Lynn, cily tolleXV//MO u.// STATE OF IDAHO www.ci.rexburq.id.0 P.O. Box 280 12 North Center Street Rexburg, Idaho 83440 Phone (208) 359-3020 Fax (208) 359-3022 e-mail rexburg@ci.rexburg.id.us I have reviewed the drawings for building #1 and the site plan of the Teton River Village (identified on the plans as American Family Entertainment Center) and have identified the following deficiencies: 1. Provide a handicap parking space adjacent to building #2. The closest handicap parking spaces are located across a vehicle access aisle. 2. Please provide a Flood Elevation Certificate as required in the 2000 International Building Code (IBC) Section 1612.5. 3. The geotechnical investigation for this site (included in the project Manual dated July 14, 2003) describes the site as being located in Seismic Zone 2B. This zone is from the 1997 Uniform Building Code (UBC). Rexburg is located in Seismic Zone 3 in the UBC. The structural design is consistent with Chapter 16 of the International Building Code. My concern is that the Geotechnical firm may have made recommendations based on this information. Provide me with a letter from this firm addressing the discrepancy. Design should be applicable to the 2000 IBC. 4. The envelope compliance energy calculations for that have been provided are for the Idaho Falls area. Our climate zone is different than Idaho Falls. The energy calculations should be for climate zone 16 of the 2000 International Energy Conservation Code. 5. The Fire Department has reviewed the plans. I have attached a copy of the report. Please provide the necessary information they have requested. These items need to be addressed before issuance of a building permit. Please let me know if you have any questions. I can be reached during the day at 359-3020 Ext. 324. Sincerely+� Val Christensen Building Official C.C. John Millar Chris Huskinson REXB UR G -MADISON COUNTY EMERGENCYSER VICES 26 NORTH CENTER STREET REXBURG, IDAHO 83440 208-359-3010 208-359-3006 FAX 2000 International Fire Code Plan Review Plan Date: 7-14-03 Review Date: 7-22-03 Building Name: AMERICAN FAMILY ENTERTAINMENT COMPLEX Building Address: 485 NORTH SECOND EAST, REXBURG, IDAHO Stories: 2 Type of Construction: H -B Occupancy Classification: A-1, A-3 Existing Floor Area: N/A New Construction Floor Area: 46,242 SQUARE FEET 1. Required Fire Flow (Appendix B): 4,500 GPM/FOUR HOURS Comments. NONE 2. Water Supply (Section 508, Appendix C) Required: YES Fire Hydrant Location: NOT ENOUGH HYDRANTS ON SITE PLAN FOR REVIEW Fire Hydrant Flows: Fire Flow Test Location: Fire Flow Supplied By: Other Approved Water Source: Water Supply Acceptable: NO Fire Hydrant Location Acceptable: NO Water Supply Comments: REQUIRED WATER FLOW INCLUDING SIZE AND TYPE OF STRUCTURE INDICATE A MINIMUM OF FIVE HYDRANTS WITHIN 300 OF STRUCTURE.