HomeMy WebLinkAboutPLANS REVIEWS - 04-00190 - Rudd & Company - Storage Shed9/2/2003
Melvin Rudd
M & J Rudd Company
209 Apache Ave.
Rexburg, ID 83440
Dear Melvin,
P.O. Box 280
elly ��� U. �x��(L�ll12 North Center Street
Rexburg, Idaho 83440
Phone (208) 359-3020
STATE OF IDAHO Fax (208) 359-3022
'i'o�h... n iH e-mail rexburg®ci.rexburg.id.us
I have reviewed the plans for the Storage Building and have identified the
following discrepancies or questions:
1. The site plan does not show an easement on the West side. It has come to my
attention that the City of Rexburg is going to provide that easement. Please
get with the party who offered the easement and provide me with a recorded
copy. I have red -lined the site plan to show a 20' wide easement and a 10'
set -back at the back of the building from property line.
2. Our frost depth is 36". The plans identify the foundation to be constructed at
30" below grade. I have red -lined the plans to show a 36" minimum depth.
The structural notes on page SO.1 identify that the foundation design was
performed using the UBC. The design must be based on the 2000
International Building Code (IBC). Please provide the necessary information
from your engineer to clear up these problems.
3. The State of Idaho has adopted the 2000 International Energy Conservation
Code. If you plan to heat this building, please provide the necessary energy
evaluation to meet the Code.
4. I have attached a copy of the Fire Department review top the back of this
document. If you have any questions concerning the fire review, please
contact Chris Huskinson at (208)359-3010.
Please provide me with the information as requested above. If you have any
questions, please give me a call at 359-3020 ext. 324.
Sincerely
Val Christensen
Building Official
C.C. John Millar
Chris Huskinson
QP uRCI o
O 0 P.O. Box 280
69/ ? X 1 M 11 7 12 North Center Street
Rexburg, Idaho 83440
> ° Phone (208) 359.3020
STATE OF IDAHO Fax (208) 359-3022
4eCrsHEO
e-mail rexburg@srv.net
MEMO:
TO: TO WHOM IT MAY CONCERN
FROM: CHRIS HUSKINSON, FIRE INSPECTOR
DATE: SEPTEMBER 2, 2003
RE: RUDD SHOP BUILDING
TO WHOM IT MAY CONCERN:
Upon review of the site plan drawings submitted the following items need to be
addressed:
1. WATER SUPPLY: Adequate with existing fire hydrants.
2. Fire extinguishers will need to be provided. The size and type of extinguishers
depends on the type of occupancy.
Additional plans are required to complete an accurate plan review of this project. If
there are any questions please feel free to contact me.
Chris Huskinson
Fire Inspector